Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (39)

Search Parameters:
Keywords = HyFlex

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
22 pages, 725 KB  
Article
A Comparative NLP-BASED Sentiment Analysis of Basic Psychological Needs and Engagement Among Students with and Without Disability Accommodations in a Design Thinking Course with HyFlex Settings
by Elnara Mammadova, Nathan Mentzer, Federico R. Waitoller and Anne Traynor
Educ. Sci. 2026, 16(3), 457; https://doi.org/10.3390/educsci16030457 - 17 Mar 2026
Abstract
Although HyFlex teaching has been studied for decades and has become part of the teaching norm since the 2020 pandemic, studies have generally not investigated the learning experiences of students with disabilities in HyFlex classrooms. This study compared the basic psychological needs (BPN) [...] Read more.
Although HyFlex teaching has been studied for decades and has become part of the teaching norm since the 2020 pandemic, studies have generally not investigated the learning experiences of students with disabilities in HyFlex classrooms. This study compared the basic psychological needs (BPN) and engagement of undergraduate students who did (SwA) and did not (SwoA) request academic disability accommodations in an introductory, active learning, human-centered design thinking course, a core component of engineering technology education. Data were collected from 3748 primarily first-year undergraduate engineering technology students between fall 2021 and spring 2024, 126 of whom requested disability accommodation through the disability office. The data sources consisted of an end-of-course survey, in which students reported their basic psychological satisfaction level on a Likert scale and described their BPN experiences and engagement in response to open-ended survey questions. As a novel contribution, this study integrates the descriptive analysis of Likert-scale measures with textual- and word-level sentiment analysis, advancing conceptual understanding of reported BPN satisfaction and engagement and revealing divergent patterns across analytic approaches. While the SwA group reported lower scores across all BPN constructs compared to their counterparts, the highest number of them provided positive feedback statements across all BPN domains. Conversely, the SwoA group reported higher BPN scores across all constructs, yet the highest number of them used negative sentiments in their responses across all BPN constructs. The majority of SwA provided positive feedback on autonomy satisfaction, while the majority of SwoA’s positive feedback was on relatedness to the instructor. Future directions for advancing engineering technology education and disability data collection in higher education are provided. Full article
(This article belongs to the Special Issue Rethinking Engineering Education)
Show Figures

Figure 1

11 pages, 1374 KB  
Article
Effect of Different Downward Loads and Rotational Speeds on the Removal of Gutta-Percha and Root Canal Sealer Using a Nickel-Titanium Rotary Gutta-Percha Removal System: An Ex Vivo Study
by Koki Toyoda, Shunsuke Kimura, Keiichiro Maki, Satoshi Omori, Keiko Hirano, Arata Ebihara and Takashi Okiji
Appl. Sci. 2026, 16(1), 446; https://doi.org/10.3390/app16010446 - 31 Dec 2025
Viewed by 282
Abstract
Effective gutta-percha/sealer removal is essential for predictable nonsurgical endodontic retreatment, but the effects of key operational parameters on nickel–titanium rotary removal instruments remain insufficiently understood. This study aimed to examine how varying downward loads and rotational speeds affect the removal efficiency and torque/force [...] Read more.
Effective gutta-percha/sealer removal is essential for predictable nonsurgical endodontic retreatment, but the effects of key operational parameters on nickel–titanium rotary removal instruments remain insufficiently understood. This study aimed to examine how varying downward loads and rotational speeds affect the removal efficiency and torque/force generation of the HyFlex Remover. Sixty transparent straight resin canals filled with gutta-percha and AH Plus sealer were prepared using the HyFlex Remover at two rotational speeds (400 and 800 rpm) and three downward loads (2, 3, and 4 N; n = 10/group). The removal rate, calculated using micro-computed tomography, as well as removal time, maximum force, maximum torque, and cumulative torque were recorded and evaluated using two-way analysis of variance with Bonferroni correction (α = 0.05). The removal rate was consistently higher at 400 rpm than at 800 rpm (p < 0.001), while removal time and cumulative torque were greater at 400 rpm (p < 0.001). Maximum torque differed only between the 800-2 N and 800-4 N groups (p = 0.006). Maximum force increased with higher loads (p < 0.001), and at 3 N and 4 N, it was lower at 400 rpm than at 800 rpm (3 N: p = 0.039, 4 N: p < 0.001). Overall, lower downward loads reduced torque but prolonged working time, whereas higher rotational speeds shortened both working time and torque but decreased the removal rate. Full article
(This article belongs to the Special Issue Recent Developments in Endodontics and Dental Materials)
Show Figures

Figure 1

10 pages, 671 KB  
Article
A Safety Limit of the Number of Artificial Canals That Can Be Prepared by Two Rotary Endodontic Files Operated at Two Different Speeds: A Novel Approach
by Omar Alzahrani, Khalid Merdad, Tariq Abuhaimed, Zuhair S. Natto, Amna Y. Siddiqui and Osama S. Alothmani
Bioengineering 2025, 12(9), 985; https://doi.org/10.3390/bioengineering12090985 - 17 Sep 2025
Viewed by 854
Abstract
Utilizing a novel approach that concomitantly assessed cyclic fatigue and torsional overloading, we aimed to establish the maximum number of artificial canals that can be prepared by Hyflex EDM and NeoNiTi A1 operated at two different speeds until their separation. Forty-eight files were [...] Read more.
Utilizing a novel approach that concomitantly assessed cyclic fatigue and torsional overloading, we aimed to establish the maximum number of artificial canals that can be prepared by Hyflex EDM and NeoNiTi A1 operated at two different speeds until their separation. Forty-eight files were equally divided into four groups: (A) Hyflex EDM operated at 300 rotations per minute (RPM) and (B) at 500 RPM, and (C) NeoNiTi A1 at 300 RPM and (D) at 500 RPM. Files were used to completely shape 10 sequential artificial canals unless file separation occurred. Maximum number of canals prepared was noted and averaged. Fractography was conducted to determine the mechanism of file separation. Hyflex EDM prepared significantly more canals compared to NeoNiTi A1 (p = 0.008). When operated at 300 RPM, Hyflex EDM prepared significantly more canals compared to NeoNiTi A1 (p = 0.028), whereas no significant difference was observed when they were operated at 500 RPM (p = 0.116). One NeoNiTi file broke due to cyclic fatigue while another one separated due to torsional overloading. Hyflex EDM files showed signs of both mechanisms. Within the limitations of this study, one file safely prepared four to five canals before its fracture. There was a trend towards fewer prepared canals as the RPM increased. Full article
(This article belongs to the Section Biomedical Engineering and Biomaterials)
Show Figures

Figure 1

10 pages, 4772 KB  
Article
Effectiveness of Nickel–Titanium Files for Retreatment of Molars Filled with Single-Cone Hydraulic Technique Using Bioceramic Sealers: An In Vitro Study
by Jane Lee, Hyeon-Cheol Kim, Timothy Kirkpatrick, David E. Jaramillo, Sang Won Kwak and Ji Wook Jeong
Materials 2025, 18(6), 1265; https://doi.org/10.3390/ma18061265 - 13 Mar 2025
Cited by 2 | Viewed by 1580
Abstract
Recently, the single-cone hydraulic canal filling technique using bioceramic sealers was found to hinder retreatment due to the mechanical properties of the bioceramic sealers. This study assessed the effectiveness of four nickel–titanium rotary files in removing gutta-percha and bioceramic sealer from molar root [...] Read more.
Recently, the single-cone hydraulic canal filling technique using bioceramic sealers was found to hinder retreatment due to the mechanical properties of the bioceramic sealers. This study assessed the effectiveness of four nickel–titanium rotary files in removing gutta-percha and bioceramic sealer from molar root canals in vitro. Eighty-eight root canals from extracted molars were instrumented with Vortex Blue rotary files and filled with gutta-percha and bioceramic sealer using a single-cone technique. After 30 days, the filled canals were randomly divided into four groups according to the file used for re-instrumentation: ProTaper Gold (PTG), Endo ReStart (ERS), XP-3D Shaper (XPD), and HyFlex Remover (HFR). This study assessed whether root canal filling material removal and patency were achieved within a 10-min time frame, recording the time required in seconds. The rate of regaining patency and the time required to achieve patency were compared among groups using a generalized linear model. Scanning electron microscopy was used to evaluate the mechanical changes to the files after use. The patency rate of XPD and HFR was significantly higher than PTG. ERS and XPD demonstrated shorter patency times than HFR and significantly shorter patency times than PTG. SEM images revealed a varied range of reverse windings across file groups. PTG and ERS exhibited microcracks and fractured tips, while XPD and HFR did not display these mechanical alterations. The four file systems in this study displayed varying levels of effectiveness in the retreatment of root canals filled with bioceramic sealers. Full article
(This article belongs to the Special Issue Properties of Dental Restorative Materials (Volume II))
Show Figures

Figure 1

12 pages, 478 KB  
Article
Comparison of Four Ni-Ti Rotary Systems: Dental Students’ Perceptions in a Multi-Center Simulated Study
by Francesco Puleio, Vincenzo Tosco, Riccardo Monterubbianesi, Rosario Pirri, Angela Alibrandi, Daria Pulvirenti and Michele Simeone
Dent. J. 2025, 13(3), 97; https://doi.org/10.3390/dj13030097 - 24 Feb 2025
Cited by 7 | Viewed by 1168
Abstract
Background/Objectives: Nickel–titanium (Ni-Ti) rotary instruments have significantly enhanced the efficiency and safety of root canal shaping. However, the variety of Ni-Ti systems, characterized by differences in alloy composition, taper design, and heat treatment, may influence their usability, particularly for novice operators. This [...] Read more.
Background/Objectives: Nickel–titanium (Ni-Ti) rotary instruments have significantly enhanced the efficiency and safety of root canal shaping. However, the variety of Ni-Ti systems, characterized by differences in alloy composition, taper design, and heat treatment, may influence their usability, particularly for novice operators. This study aimed to evaluate the perceptions of dental students using four Ni-Ti rotary systems (MTwo, SlimShaper Pro, ProTaper Gold, and HyFlex EDM) in a simulated environment. Methods: Forty dental students from two universities participated in the study and completed a standardized preoperative training session. Root canal shaping was performed on resin teeth models, and an 11-item questionnaire was used to assess various parameters, including flexibility, ease of use, and the ability to maintain working length. Results: The results indicated significant differences in student feedback. SlimShaper Pro and HyFlex EDM were preferred for their flexibility, reduced resistance, and ease of instrument transitions, likely due to their smaller tapers and martensitic alloys. MTwo was rated the least flexible and more challenging to use. Conclusions: These findings underline the importance of user-friendly Ni-Ti systems in pre-clinical training to reduce procedural difficulties and operator stress. Further research should validate these findings in clinical settings to improve the training of novice operators. Full article
(This article belongs to the Special Issue Dental Education: Innovation and Challenge)
Show Figures

Figure 1

12 pages, 1282 KB  
Article
Quantitative Assessment of Apically Extruded Debris During Retreatment Procedures Using Three Nickel-Titanium Rotary Systems: An In Vitro Comparative Study
by Luigi Generali, Federica Veneri, Francesco Cavani, Vittorio Checchi, Carlo Bertoldi, Angela Lucia Ingrosso, Giusy Rita Maria La Rosa and Eugenio Pedullà
Dent. J. 2024, 12(12), 384; https://doi.org/10.3390/dj12120384 - 26 Nov 2024
Cited by 1 | Viewed by 1967
Abstract
Objectives: Apical extrusion of debris can affect the success of endodontic treatments, and the specific performance of certain retreatment systems has not been studied yet. Therefore, the aim of this in vitro study was to quantitatively assess the amount of apically extruded [...] Read more.
Objectives: Apical extrusion of debris can affect the success of endodontic treatments, and the specific performance of certain retreatment systems has not been studied yet. Therefore, the aim of this in vitro study was to quantitatively assess the amount of apically extruded debris produced during retreatment procedures using three rotary NiTi retreatment systems in mature non-resorbed straight roots. Methods: Thirty extracted permanent human teeth with single straight roots were selected. The root canals were prepared with the ProTaper Next system up to size 30 and obturated with gutta-percha and AH Plus sealer using the continuous wave of condensation technique. The samples were stored for 30 days and randomized by computer sequence into three retreatment groups (n = 10): (1) ProTaper Universal Retreatment; (2) HyFlex Remover; and (3) VDW.Rotate Retreatment. Apically extruded debris was collected in Eppendorf tubes and weighed with a microbalance (10−5 g) before and after retreatment procedure. As the data were not normally distributed, the Kruskal–Wallis test was applied for comparing data among groups, with an alpha level set at α = 0.05. Dunn’s test was considered for post-hoc analyses, if appropriate. Results: Hyflex Remover was associated with the highest amount of extruded debris (0.85 ± 0.82 mg), followed by VDW.Rotate Retreatment (0.78 ± 0.41 mg) and ProTaper Universal Retreatment (0.62 ± 0.28 mg). However, the differences were not statistically significant (p > 0.05). Conclusions: All the retreatment systems tested were associated with apical extrusion of debris in vitro, with no significant quantitative differences between them, suggesting that clinicians can choose a retreatment system with features appropriate to the specific clinical situation without risk of increasing the amount of apically extruded debris. Full article
(This article belongs to the Special Issue Endodontics: From Technique to Regeneration)
Show Figures

Graphical abstract

34 pages, 8298 KB  
Article
Virtual Plug-In Hybrid Concept Development and Optimization under Real-World Boundary Conditions
by Jannik Kexel, Jonas Müller, Ferris Herkenrath, Philipp Hermsen, Marco Günther and Stefan Pischinger
Vehicles 2024, 6(3), 1216-1248; https://doi.org/10.3390/vehicles6030058 - 15 Jul 2024
Cited by 2 | Viewed by 2680
Abstract
The automotive industry faces development challenges due to emerging technologies, regulatory demands, societal trends, and evolving customer mobility needs. These factors contribute to a wide range of vehicle variants and increasingly complex powertrains. The layout of a vehicle is usually based on standardized [...] Read more.
The automotive industry faces development challenges due to emerging technologies, regulatory demands, societal trends, and evolving customer mobility needs. These factors contribute to a wide range of vehicle variants and increasingly complex powertrains. The layout of a vehicle is usually based on standardized driving cycles such as WLTC, gradeability, acceleration test cases, and many more. In real-world driving cycles, however, this can lead to limitations under certain boundary conditions. To ensure that all customer requirements are met, vehicle testing is conducted under extreme environmental conditions, e.g., in Sweden or Spain. One way to reduce the development time while ensuring high product quality and cost-effectiveness is to use model-based methods for the comprehensive design of powertrains. This study presents a layout methodology using a top-down approach. Initially, powertrain-relevant requirements for an exemplary target customer are translated into a specification sheet with specific test cases. An overall vehicle model with detailed thermal sub-models is developed to evaluate the different requirements. A baseline design for a C-segment plug-in hybrid vehicle was developed as part of the FVV research project HyFlex-ICE using standardized test cases, highlighting the influence of customer profiles on the design outcome through varying weighting factors. The target customer’s design is analyzed in four real driving scenarios, considering variations in parameters such as the ambient temperature, traffic, driver type, trailer pulling, and battery state-of-charge, to assess their influence on the target variables. In the next step, the potential of hardware technologies and predictive driving functions is examined in selected driving scenarios based on the identified constraints of the baseline design. As a result, four application-specific technology packages (Cost neutral, Cold country, Hot country, and Premium) for different customer requirements and sales markets are defined, which, finally, demonstrates the applicability of the holistic methodology. Full article
(This article belongs to the Special Issue Vehicle Design Processes, 2nd Edition)
Show Figures

Figure 1

10 pages, 1018 KB  
Article
Evaluation of Mechanical Versus Manual Root Canal Preparation in Primary Molars—A Comparative In Vitro Study
by Nelly Schulz-Weidner, Jiameng Wang, Jessica Steinbart, Anton G. Windfelder, Gabriele A. Krombach, Norbert Krämer, Maximiliane A. Schlenz and Jan Scherberich
J. Clin. Med. 2023, 12(24), 7718; https://doi.org/10.3390/jcm12247718 - 15 Dec 2023
Cited by 3 | Viewed by 2808
Abstract
The endodontic treatment of primary teeth is to maintain the function of the tooth free of symptoms until its physiological exfoliation. A critical factor for success is how quickly and effectively the root canal preparation can be performed. Therefore, the aim of this [...] Read more.
The endodontic treatment of primary teeth is to maintain the function of the tooth free of symptoms until its physiological exfoliation. A critical factor for success is how quickly and effectively the root canal preparation can be performed. Therefore, the aim of this comparative in vitro study was to analyze the efficiency of two mechanical root canal preparation systems FM (FlexMaster) and HF (HyFlex EDM) to manual KF (K-file) on extracted primary molars. A total of 45 teeth were divided into three groups (n = 15): KF (#15–35), FM (04#30) and HF (25/~ OneFile). Root canal preparation was performed, and the preparation time was measured. All root canals were non-destructively analyzed by micro-computed tomography in the cervical, middle and apical thirds before and after preparation with regard to the parameters of canal transport (in μm) and centering ratio (0–1). Statistical analysis was performed at a 5% significance level using non-parametric tests. HF caused the lowest canal transport in the apical third (p = 0.008). The centering ratio value of HF was significantly higher in the middle third of the root canals than in the other two groups (p < 0.01). The mean instrumentation time was significantly higher for KF (6.67 min) than for FM (4.69 min) and HF (4.03 min, p < 0.01). HF can be recommended for primary molar root canal treatment. Full article
(This article belongs to the Special Issue Advances in the Diagnosis and Treatment of Endodontic Diseases)
Show Figures

Graphical abstract

20 pages, 2846 KB  
Article
Identifying Barriers to Basic Needs, Academic Success, and the Vaccination Pattern among College Students during the COVID-19 Pandemic
by Subi Gandhi, Ryan Glaman, Alexandra Jordan, Dylan DiChristofaro, Katelyn Clark, Viraj Gandhi and Jade Smith
Int. J. Environ. Res. Public Health 2023, 20(20), 6924; https://doi.org/10.3390/ijerph20206924 - 14 Oct 2023
Cited by 4 | Viewed by 3771
Abstract
College students face significant challenges during large-scale disease outbreaks that potentially compromise their basic needs, vaccine confidence, and academic success. Using a cross-sectional design and convenience sampling, we examined the impact of COVID-19 among college students (N = 828). The survey was [...] Read more.
College students face significant challenges during large-scale disease outbreaks that potentially compromise their basic needs, vaccine confidence, and academic success. Using a cross-sectional design and convenience sampling, we examined the impact of COVID-19 among college students (N = 828). The survey was administered using the Qualtrics survey platform to collect data on multiple demographic and health behaviors of students in the summer semester (2021). Our study demonstrated that the most common financial shock experienced by the study participants was job loss, with less remarkable changes in food and housing insecurities. Academically, students had the most difficulty learning online compared to other modalities (face-to-face, Hyflex, etc.) and struggled with staying motivated. They also struggled with group work and finding appropriate learning spaces. However, many did not use university support systems such as career and tutoring services. Exploring the COVID-19 vaccination attitudes, we found that only age, ethnicity, classification, and health insurance status were associated with getting vaccinated (p < 0.05). When the learning environment was assessed for various modalities, only college attendance was significantly associated (p < 0.05) with the accessible platforms (online, Hyflex, face-to-face, and others); however, nearly 40% of students reported difficulty learning on an online learning platform compared other categories that had much lower proportions. Our findings underscore an immediate need for universities to take measures to improve their preparedness and response strategies to mitigate the negative effects of future large-scale public health emergencies among students. Full article
(This article belongs to the Special Issue Population Health: Infectious Disease Research)
Show Figures

Graphical abstract

25 pages, 8268 KB  
Article
Using Sentinel-2-Based Metrics to Characterize the Spatial Heterogeneity of FLEX Sun-Induced Chlorophyll Fluorescence on Sub-Pixel Scale
by Nela Jantol, Egor Prikaziuk, Marco Celesti, Itza Hernandez-Sequeira, Enrico Tomelleri, Javier Pacheco-Labrador, Shari Van Wittenberghe, Filiberto Pla, Subhajit Bandopadhyay, Gerbrand Koren, Bastian Siegmann, Tarzan Legović, Hrvoje Kutnjak and M. Pilar Cendrero-Mateo
Remote Sens. 2023, 15(19), 4835; https://doi.org/10.3390/rs15194835 - 5 Oct 2023
Cited by 4 | Viewed by 4136
Abstract
Current and upcoming Sun-Induced chlorophyll Fluorescence (SIF) satellite products (e.g., GOME, TROPOMI, OCO, FLEX) have medium-to-coarse spatial resolutions (i.e., 0.3–80 km) and integrate radiances from different sources into a single ground surface unit (i.e., pixel). However, intrapixel heterogeneity, i.e., different soil and vegetation [...] Read more.
Current and upcoming Sun-Induced chlorophyll Fluorescence (SIF) satellite products (e.g., GOME, TROPOMI, OCO, FLEX) have medium-to-coarse spatial resolutions (i.e., 0.3–80 km) and integrate radiances from different sources into a single ground surface unit (i.e., pixel). However, intrapixel heterogeneity, i.e., different soil and vegetation fractional cover and/or different chlorophyll content or vegetation structure in a fluorescence pixel, increases the challenge in retrieving and quantifying SIF. High spatial resolution Sentinel-2 (S2) data (20 m) can be used to better characterize the intrapixel heterogeneity of SIF and potentially extend the application of satellite-derived SIF to heterogeneous areas. In the context of the COST Action Optical synergies for spatiotemporal SENsing of Scalable ECOphysiological traits (SENSECO), in which this study was conducted, we proposed direct (i.e., spatial heterogeneity coefficient, standard deviation, normalized entropy, ensemble decision trees) and patch mosaic (i.e., local Moran’s I) approaches to characterize the spatial heterogeneity of SIF collected at 760 and 687 nm (SIF760 and SIF687, respectively) and to correlate it with the spatial heterogeneity of selected S2 derivatives. We used HyPlant airborne imagery acquired over an agricultural area in Braccagni (Italy) to emulate S2-like top-of-the-canopy reflectance and SIF imagery at different spatial resolutions (i.e., 300, 20, and 5 m). The ensemble decision trees method characterized FLEX intrapixel heterogeneity best (R2 > 0.9 for all predictors with respect to SIF760 and SIF687). Nevertheless, the standard deviation and spatial heterogeneity coefficient using k-means clustering scene classification also provided acceptable results. In particular, the near-infrared reflectance of terrestrial vegetation (NIRv) index accounted for most of the spatial heterogeneity of SIF760 in all applied methods (R2 = 0.76 with the standard deviation method; R2 = 0.63 with the spatial heterogeneity coefficient method using a scene classification map with 15 classes). The models developed for SIF687 did not perform as well as those for SIF760, possibly due to the uncertainties in fluorescence retrieval at 687 nm and the low signal-to-noise ratio in the red spectral region. Our study shows the potential of the proposed methods to be implemented as part of the FLEX ground segment processing chain to quantify the intrapixel heterogeneity of a FLEX pixel and/or as a quality flag to determine the reliability of the retrieved fluorescence. Full article
Show Figures

Figure 1

17 pages, 468 KB  
Article
“Girls Hold All the Power in the World”: Cultivating Sisterhood and a Counterspace to Support STEM Learning with Black Girls
by Erica B. Edwards and Natalie S. King
Educ. Sci. 2023, 13(7), 698; https://doi.org/10.3390/educsci13070698 - 9 Jul 2023
Cited by 10 | Viewed by 4318
Abstract
For far too long, schools have been violent places where Black girls are often adultified, overdisciplined, and overlooked. In school science and mathematics specifically, Black girls have been isolated, tokenized, and made to feel invisible. This qualitative study leveraged the Multidimensionality of Black [...] Read more.
For far too long, schools have been violent places where Black girls are often adultified, overdisciplined, and overlooked. In school science and mathematics specifically, Black girls have been isolated, tokenized, and made to feel invisible. This qualitative study leveraged the Multidimensionality of Black Girls’ STEM Learning conceptual framework to explore the roles of two Black women middle school science and mathematics teachers on the STEM learning experiences of 12 Black girls who live in the U.S. Midwest and how the girls engage with culturally relevant lessons in an afterschool program—SISTERHOOD I AM STEM. Data sources included a demographic questionnaire, program artifacts, and semi-structured transformative dialogic interviews with student and teacher participants. Findings revealed the significance and benefits of single-gender STEM learning environments for Black girls who struggle to connect with school and the role of Black women teachers in creating safe spaces for STEM engagement. In addition, the afterschool STEM program served as a mechanism to promote self-visualization and confidence for Black girls in science with the HyFlex model fostering a communal experience for the girls and their families. This STEM learning space organized and facilitated by Black women educators resisted Black girls’ pathologization and cultivated their sense of belonging. It holds promise for developing the social bonds that are critically important to their persistence in the field and a new narrative where “Girls hold all the power in the world”. Full article
(This article belongs to the Special Issue Educational Equity: Cultural and Ethnic Diversity in Schools)
Show Figures

Figure 1

18 pages, 4028 KB  
Review
HyFlex Learning Research and Practice: A Longitudinal Analysis
by Billy T. M. Wong, Kam Cheong Li, Hon Tung Chan and Simon K. S. Cheung
Sustainability 2023, 15(12), 9699; https://doi.org/10.3390/su15129699 - 17 Jun 2023
Cited by 31 | Viewed by 7157
Abstract
This paper presents a longitudinal study analysing the literature on the hybrid and flexible mode of learning (HyFlex learning) in terms of its research and practice over the past decade. A total of 84 articles published between 2013 and 2022 were collected from [...] Read more.
This paper presents a longitudinal study analysing the literature on the hybrid and flexible mode of learning (HyFlex learning) in terms of its research and practice over the past decade. A total of 84 articles published between 2013 and 2022 were collected from Scopus for analysis, covering their changes in publication patterns, research issues, features of practices, benefits, and challenges, as well as the recommendations given in the articles along the years. The results show a sharp increase in publications since 2018. Relevant work was primarily carried out at the tertiary level of education, with an emphasis on issues in respect of teachers’ and students’ perceptions, experiences, and behaviours in HyFlex learning. Most of the practices were mediated by technologies, which were primarily used for course delivery, course management, and in-class/off-class communication. The recommendations made in the literature cover the roles of teachers and institutions as well as relevant support, which are noted to have an impact on the effective implementation of HyFlex learning. The findings contribute to providing an overview of the longitudinal development and current state of HyFlex learning as well as insights into its future development in both research and practice. Full article
(This article belongs to the Special Issue Sustainable Inspiration of Flexible Education)
Show Figures

Figure 1

15 pages, 4359 KB  
Article
Cleaning and Disinfecting Oval-Shaped Root Canals: Ex Vivo Evaluation of Three Rotary Instrumentation Systems with Passive Ultrasonic Irrigation
by Ying Li, Zhengyang Wang, Pingping Bao, Tingting Meng, Meng Liu, Huixu Li, Ya Shen, Dayong Liu, Zhi Jia and He Liu
Medicina 2023, 59(5), 962; https://doi.org/10.3390/medicina59050962 - 16 May 2023
Cited by 25 | Viewed by 3949
Abstract
Background and Objectives: Successful root canal treatment depends on the thorough removal of biofilms through chemomechanical preparation. This study aimed to investigate and compare the cleaning and disinfecting efficiency of oval-shaped root canals using XP-endo Shaper (XPS), ProTaper Next (PTN), and HyFlex [...] Read more.
Background and Objectives: Successful root canal treatment depends on the thorough removal of biofilms through chemomechanical preparation. This study aimed to investigate and compare the cleaning and disinfecting efficiency of oval-shaped root canals using XP-endo Shaper (XPS), ProTaper Next (PTN), and HyFlex CM (HCM) in combination with passive ultrasonic irrigation (PUI). Materials and Methods: Ninety extracted teeth were contaminated and randomly divided into three groups: XPS, PTN, and HCM. Each group was assigned to three subgroups: subgroup A (sterile saline), subgroup B (3% sodium hypochlorite and 17% ethylenediaminetetraacetic acid), and subgroup C (3% sodium hypochlorite, 17% ethylenediaminetetraacetic acid, and PUI). Bacterial sampling was conducted both from baseline samples and samples after chemomechanical preparation. Scanning electron microscopy (SEM) was used to evaluate the residue bacterial biofilms, hard tissue debris, and smear layers on the buccolingual walls of oval-shaped root canals. Results: When combined with sterile saline, XPS demonstrated a higher reduction of bacterial counts and was more effective in eradicating Enterococcus faecalis in the middle third of the canals compared to the other instruments (p < 0.05). Additionally, when used with antimicrobial irrigants, XPS was more effective in disinfecting the coronal third of the canals than the other instruments (p < 0.05). Furthermore, XPS reduced hard tissue debris more effectively in the middle third of canals than in the apical third (p < 0.05). Conclusions: XPS outperforms PTN and HCM in disinfecting oval-shaped root canals. Despite the fact that combining XPS and PUI improves cleaning and disinfecting, removing hard tissue debris from the critical apical area remains challenging. Full article
(This article belongs to the Special Issue Nickel-Titanium Rotary Instruments in Endodontics)
Show Figures

Figure 1

13 pages, 259 KB  
Article
Evaluation of Hybrid Learning and Teaching Practices: The Perspective of Academics
by Kam Cheong Li, Billy T. M. Wong, Reggie Kwan, Hon Tung Chan, Manfred M. F. Wu and Simon K. S. Cheung
Sustainability 2023, 15(8), 6780; https://doi.org/10.3390/su15086780 - 17 Apr 2023
Cited by 47 | Viewed by 16107
Abstract
This paper presents a study on the evaluation of hybrid learning and teaching practices by academics. A mixed research method involving a questionnaire survey and a focus group interview was employed to gather academics’ feedback on their experience in delivering hybrid instruction in [...] Read more.
This paper presents a study on the evaluation of hybrid learning and teaching practices by academics. A mixed research method involving a questionnaire survey and a focus group interview was employed to gather academics’ feedback on their experience in delivering hybrid instruction in a synchronous manner in which on-site and remote students attended classes simultaneously, their students’ hybrid learning effectiveness, and their suggestions for improvement. The questionnaire was administered to 76 academics from a university in Hong Kong where hybrid learning and teaching were implemented, and the focus group interview involved 10 academics. The findings reveal that the participating academics perceived themselves as having an overall high degree of readiness to handle technical issues. They expressed that the students from their hybrid classes had lower levels of interaction, engagement, and motivation than those from traditional face-to-face classes. The participants also reported their challenges regarding hybrid learning and teaching, including heavy workload for lesson preparation and face-to-face and online classroom management, unfamiliarity with interactive teaching design suitable for hybrid classes, and difficulties in monitoring students’ learning process. They provided suggestions for the improvement of hybrid classes, ranging from the provision of technological support to professional development for enhancing students’ online interaction and engagement. These findings contribute to revealing academics’ experience in practising hybrid learning and teaching and identifying ways to address their challenges. Full article
(This article belongs to the Special Issue Sustainable Inspiration of Flexible Education)
17 pages, 4987 KB  
Article
Mechanical Properties of NiTi Rotary Files Fabricated through Gold-Wire, CM-Wire, T-Wire, and R-Phase Heat Treatment
by Soram Oh, Tae-Hwan Kim and Seok Woo Chang
Appl. Sci. 2023, 13(6), 3604; https://doi.org/10.3390/app13063604 - 11 Mar 2023
Cited by 6 | Viewed by 9109
Abstract
Although nickel–titanium (NiTi) rotary files are invaluable tools in dentistry, the relationship between their properties and performance has not been elucidated. Herein, the performance of gold heat-treated (ProTaper Gold and ProfaTaper Gold), controlled memory (CM)-wire (HyFlex CM and V Taper 2H), T-wire (2Shape), [...] Read more.
Although nickel–titanium (NiTi) rotary files are invaluable tools in dentistry, the relationship between their properties and performance has not been elucidated. Herein, the performance of gold heat-treated (ProTaper Gold and ProfaTaper Gold), controlled memory (CM)-wire (HyFlex CM and V Taper 2H), T-wire (2Shape), and R-phase heat-treated (K3XF) NiTi files was evaluated; the non-heat-treated ProFile was used as the control. The bending, buckling, cyclic fatigue, and torsional resistances of the NiTi files were determined, and their phase transformation behavior was studied through differential scanning calorimetry (DSC). The angle of rotation until fracture (ARF), ultimate torsional strength (UTS), and stiffness were evaluated via torsional resistance testing. One-way analysis of variance (ANOVA) and post hoc analyses were conducted using the Games–Howell test and Tukey’s test. ProFile displayed the highest buckling resistance (8 N), CM-wire NiTi files exhibited the lowest bending resistance (0.660–0.758 N cm), and HyFlex CM displayed the highest cyclic fatigue resistance. ProTaper Gold exhibited high UTS and low ARF. K3XF demonstrated high bending resistance and the lowest cyclic fatigue resistance. The CM-wire NiTi files were the most suitable for use in curved canals, while the gold-wire NiTi files were ideal for constricted canals. ProFile was recommended for use in re-treatment cases. Full article
(This article belongs to the Special Issue Biotechnology Applied to Dentistry and Oral Maxillofacial Surgery)
Show Figures

Figure 1

Back to TopTop