Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Article Types

Countries / Regions

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Search Results (1,321)

Search Parameters:
Keywords = Figures-of-merit

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
12 pages, 1829 KiB  
Article
Flexible Color Filter Using Lithium Niobate Metamaterial with Ultrahigh Purity and Brightness Characteristics
by Siqiang Zhao, Daoye Zheng, Yunche Zhu, Shuyan Zou and Yu-Sheng Lin
Photonics 2025, 12(8), 768; https://doi.org/10.3390/photonics12080768 - 30 Jul 2025
Viewed by 245
Abstract
We propose a simulation-based design for a flexible color filter (FCF) using a lithium niobate metamaterial (LNM) to investigate its color filtering potential. The FCF is composed of three periodically arranged half-ellipse LN arrays on a polydimethylsiloxane (PDMS) substrate, denoted as LNM-1, LNM-2, [...] Read more.
We propose a simulation-based design for a flexible color filter (FCF) using a lithium niobate metamaterial (LNM) to investigate its color filtering potential. The FCF is composed of three periodically arranged half-ellipse LN arrays on a polydimethylsiloxane (PDMS) substrate, denoted as LNM-1, LNM-2, and LNM-3. The electromagnetic responses of the FCF can be controlled by adjusting the periods of the LNMs. Our simulations predict high-quality (Q) factors in transmission spectra, ranging from 100 to 200 for LNM-1, 290 to 360 for LNM-2, and 140 to 300 for LNM-3. When the FCF is exposed to the surrounding environments with different refractive indexes, it exhibits a theoretical figure of merit (FOM) up to 900 RIU−1 and a sensitivity reaching 130 nm/RIU. The electromagnetic field distributions reveal strong confinement within the LNM nanostructures, confirming an efficient light–matter interaction. These results indicate that the proposed LNM-based FCF presents a promising design concept for high-performance color sensing and filtering applications. Full article
(This article belongs to the Special Issue Photonics Metamaterials: Processing and Applications)
Show Figures

Figure 1

16 pages, 2223 KiB  
Article
Plasmonic Sensing Design for Measuring the Na+/K+ Concentration in an Electrolyte Solution Based on the Simulation of Optical Principles
by Hongfu Chen, Shubin Yan, Yi Sun, Youbo Hu, Taiquan Wu and Yuntang Li
Photonics 2025, 12(8), 758; https://doi.org/10.3390/photonics12080758 - 28 Jul 2025
Viewed by 213
Abstract
Based on the theory of optical sensing, we propose a high-precision plasmonic refractive index nanosensor, which consists of a symmetric rectangular waveguide and a circular ring containing a rectangular cavity. The designed novel tunable micro-resonant circular cavity filter based on surface plasmon excitations [...] Read more.
Based on the theory of optical sensing, we propose a high-precision plasmonic refractive index nanosensor, which consists of a symmetric rectangular waveguide and a circular ring containing a rectangular cavity. The designed novel tunable micro-resonant circular cavity filter based on surface plasmon excitations is able to confine light to sub-wavelength dimensions. The data show that different geometrical factors have different effects on sensing, with the geometry of the rectangular cavity and the radius of the circular ring being the key factors affecting the Fano resonance. Furthermore, the resonance bifurcation enables the structure to achieve a tunable dual Fano resonance system. The structure was tuned to obtain optimal sensitivity (S) and figure of merit values up to 3066 nm/RIU and 78. The designed structure has excellent sensing performance with sensitivities of 0.4767 nm·(mg/dL1) and 0.6 nm·(mg/dL1) in detecting Na+ and K+ concentrations in the electrolyte solution, respectively, and can be easily achieved by the spectrometer. The wavelength accuracy of 0.001 nm can be easily achieved by a spectrum analyzer, which has a broad application prospect in the field of optical integration. Full article
Show Figures

Figure 1

21 pages, 11260 KiB  
Article
GaN HEMT Oscillators with Buffers
by Sheng-Lyang Jang, Ching-Yen Huang, Tzu Chin Yang and Chien-Tang Lu
Micromachines 2025, 16(8), 869; https://doi.org/10.3390/mi16080869 - 28 Jul 2025
Viewed by 250
Abstract
With their superior switching speed, GaN high-electron-mobility transistors (HEMTs) enable high power density, reduce energy losses, and increase power efficiency in a wide range of applications, such as power electronics, due to their high breakdown voltage. GaN-HEMT devices are subject to long-term reliability [...] Read more.
With their superior switching speed, GaN high-electron-mobility transistors (HEMTs) enable high power density, reduce energy losses, and increase power efficiency in a wide range of applications, such as power electronics, due to their high breakdown voltage. GaN-HEMT devices are subject to long-term reliability due to the self-heating effect and lattice mismatch between the SiC substrate and the GaN. Depletion-mode GaN HEMTs are utilized for radio frequency applications, and this work investigates three wide-bandgap (WBG) GaN HEMT fixed-frequency oscillators with output buffers. The first GaN-on-SiC HEMT oscillator consists of an HEMT amplifier with an LC feedback network. With the supply voltage of 0.8 V, the single-ended GaN oscillator can generate a signal at 8.85 GHz, and it also supplies output power of 2.4 dBm with a buffer supply of 3.0 V. At 1 MHz frequency offset from the carrier, the phase noise is −124.8 dBc/Hz, and the figure of merit (FOM) of the oscillator is −199.8 dBc/Hz. After the previous study, the hot-carrier stressed RF performance of the GaN oscillator is studied, and the oscillator was subject to a drain supply of 8 V for a stressing step time equal to 30 min and measured at the supply voltage of 0.8 V after the step operation for performance benchmark. Stress study indicates the power oscillator with buffer is a good structure for a reliable structure by operating the oscillator core at low supply and the buffer at high supply. The second balanced oscillator can generate a differential signal. The feedback filter consists of a left-handed transmission-line LC network by cascading three unit cells. At a 1 MHz frequency offset from the carrier of 3.818 GHz, the phase noise is −131.73 dBc/Hz, and the FOM of the 2nd oscillator is −188.4 dBc/Hz. High supply voltage operation shows phase noise degradation. The third GaN cross-coupled VCO uses 8-shaped inductors. The VCO uses a pair of drain inductors to improve the Q-factor of the LC tank, and it uses 8-shaped inductors for magnetic coupling noise suppression. At the VCO-core supply of 1.3 V and high buffer supply, the FOM at 6.397 GHz is −190.09 dBc/Hz. This work enhances the design techniques for reliable GaN HEMT oscillators and knowledge to design high-performance circuits. Full article
(This article belongs to the Special Issue Research Trends of RF Power Devices)
Show Figures

Figure 1

22 pages, 414 KiB  
Article
The Appearance and Disappearance of Ryukyu: The Historical Views of Tō Teikan, Motoori Norinaga, and Ueda Akinari
by Mark Thomas McNally
Histories 2025, 5(3), 32; https://doi.org/10.3390/histories5030032 - 24 Jul 2025
Viewed by 268
Abstract
Two of the renowned figures of Edo-era Kokugaku (National Learning), Motoori Norinaga and Ueda Akinari, famously debated the merits of their scholarly approaches to Japanese antiquity during the latter half of the eighteenth century. Their intellectual dispute was the result of the radical [...] Read more.
Two of the renowned figures of Edo-era Kokugaku (National Learning), Motoori Norinaga and Ueda Akinari, famously debated the merits of their scholarly approaches to Japanese antiquity during the latter half of the eighteenth century. Their intellectual dispute was the result of the radical conclusions reached by Tō Teikan in his Shōkōhatsu (An Outburst of Provocations; 1781) in which he argued that the Korean peninsula and China influenced ancient Japan, and that Japan’s first emperor, Jimmu, was from Ryukyu. While Akinari supported the notion of continental influence on ancient Japan, Norinaga did not, and while the former was mostly agnostic about Jimmu’s Ryukyuan roots, the latter opposed that as well. Norinaga, however, was not opposed to the idea of ancient ties between Ryukyu and Japan, an issue with which Akinari’s silence seemed to signify some degree of agreement. This commonality between these two intellectual giants demonstrated the extent to which Japanese intellectuals of the Edo period viewed the Ryukyu Kingdom (now Okinawa Prefecture) as occupying an ambivalent geopolitical space, in which it was neither fully foreign nor fully native. At the same time, Akinari’s historiographical approach to Japanese antiquity, which emerged in his debate with Norinaga, exerted an influence on nineteenth-century depictions of Ryukyu’s historical and cultural ties to Japan, chiefly Kyokutei Bakin’s Chinsetsu yumiharizuki (Fantastic Tales of the Moon Bow; 1811). Full article
(This article belongs to the Section Cultural History)
13 pages, 1952 KiB  
Article
Real-Time Dose Measurement in Brachytherapy Using Scintillation Detectors Based on Ce3+-Doped Garnet Crystals
by Sandra Witkiewicz-Łukaszek, Bogna Sobiech, Janusz Winiecki and Yuriy Zorenko
Crystals 2025, 15(8), 669; https://doi.org/10.3390/cryst15080669 - 23 Jul 2025
Viewed by 219
Abstract
Conventional detectors based on ionization chambers, semiconductors, or thermoluminescent materials generally cannot be used to verify the in vivo dose delivered during brachytherapy treatments with γ-ray sources. However, certain adaptations and alternative methods, such as the use of miniaturized detectors or other specialized [...] Read more.
Conventional detectors based on ionization chambers, semiconductors, or thermoluminescent materials generally cannot be used to verify the in vivo dose delivered during brachytherapy treatments with γ-ray sources. However, certain adaptations and alternative methods, such as the use of miniaturized detectors or other specialized techniques, have been explored to address this limitation. One approach to solving this problem involves the use of dosimetric materials based on efficient scintillation crystals, which can be placed in the patient’s body using a long optical fiber inserted intra-cavernously, either in front of or next to the tumor. Scintillation crystals with a density close to that of tissue can be used in any location, including the respiratory tract, as they do not interfere with dose distribution. However, in many cases of radiation therapy, the detector may need to be positioned behind the target. In such cases, the use of heavy, high-density, and high-Zeff scintillators is strongly preferred. The delivered radiation dose was registered using the radioluminescence response of the crystal scintillator and recorded with a compact luminescence spectrometer connected to the scintillator via a long optical fiber (so-called fiber-optic dosimeter). This proposed measurement method is completely non-invasive, safe, and can be performed in real time. To complete the abovementioned task, scintillation detectors based on YAG:Ce (ρ = 4.5 g/cm3; Zeff = 35), LuAG:Ce (ρ = 6.75 g/cm3; Zeff = 63), and GAGG:Ce (ρ = 6.63 g/cm3; Zeff = 54.4) garnet crystals, with different densities ρ and effective atomic numbers Zeff, were used in this work. The results obtained are very promising. We observed a strong linear correlation between the dose and the scintillation signal recorded by the detector system based on these garnet crystals. The measurements were performed on a specially prepared phantom in the brachytherapy treatment room at the Oncology Center in Bydgoszcz, where in situ measurements of the applied dose in the 0.5–8 Gy range were performed, generated by the 192Ir (394 keV) γ-ray source from the standard Fexitron Elektra treatment system. Finally, we found that GAGG:Ce crystal detectors demonstrated the best figure-of-merit performance among all the garnet scintillators studied. Full article
(This article belongs to the Special Issue Recent Advances in Scintillator Materials)
Show Figures

Figure 1

16 pages, 4562 KiB  
Article
Preparation and Properties of Flexible Multilayered Transparent Conductive Films on Substrate with High Surface Roughness
by Mengfan Li, Kai Tao, Jinghan Lu, Shenyue Xu, Yuanyuan Sun, Yaman Chen and Zhiyong Liu
Materials 2025, 18(14), 3389; https://doi.org/10.3390/ma18143389 - 19 Jul 2025
Viewed by 323
Abstract
The flexible transparent conductive films (TCFs) of a ZnS/Cu/Ag/TiO2 multilayered structure were deposited on a flexible PET substrate with high surface roughness using magnetic sputtering, and the effects of structural characteristics on the performance of the films were analyzed. The TCFs with [...] Read more.
The flexible transparent conductive films (TCFs) of a ZnS/Cu/Ag/TiO2 multilayered structure were deposited on a flexible PET substrate with high surface roughness using magnetic sputtering, and the effects of structural characteristics on the performance of the films were analyzed. The TCFs with TiO2/Cu/Ag/TiO2 and ZnS/Cu/Ag/ZnS symmetric structures were also prepared for comparison. The TCF samples were deposited using ZnS, TiO2, Cu and Ag targets, and they were analyzed using scanning electronic microscopy, atomic force microscopy, grazing incidence X-ray diffraction, spectrophotometry and a four-probe tester. The TCFs exhibit generally uniform surface morphology, excellent light transmittance and electrical conductivity with optimized structure. The optimal values are 84.40%, 5.52 Ω/sq and 33.19 × 10−3 Ω−1 for the transmittance, sheet resistance and figure of merit, respectively, in the visible spectrum. The satisfactory properties of the asymmetric multilayered TCF deposited on a rough-surface substrate should be mainly attributed to the optimized structure parameters and reasonable interfacial compatibilities. Full article
(This article belongs to the Section Thin Films and Interfaces)
Show Figures

Figure 1

14 pages, 3314 KiB  
Article
High-Performance Guided Mode Resonance Optofluidic Sensor
by Liang Guo, Lei Xu and Liying Liu
Sensors 2025, 25(14), 4386; https://doi.org/10.3390/s25144386 - 14 Jul 2025
Viewed by 539
Abstract
This paper reports on the high performance of a thick-waveguide guided mode resonance (GMR) sensor. Theoretical calculations revealed that when light incidents on the grating and excites the negative first-order diffraction order, by increasing the waveguide thickness, both a high sensitivity and high [...] Read more.
This paper reports on the high performance of a thick-waveguide guided mode resonance (GMR) sensor. Theoretical calculations revealed that when light incidents on the grating and excites the negative first-order diffraction order, by increasing the waveguide thickness, both a high sensitivity and high figure of merit (FOM) can be obtained. Experimentally, we achieved a sensitivity of 1255.78 nm/RIU, a resonance linewidth of 0.59 nm at the resonance wavelength of 535 nm, an FOM as high as 2128 RIU−1, and a detection limit as low as 1.74 × 10−7 RIU. To our knowledge, this performance represents the highest comprehensive level for current GMR sensors. Additionally, the use of a microfluidic hemisphere and polymer materials effectively reduces the liquid consumption under oblique incidence and the fabrication cost in practical application. Overall, the proposed GMR sensor exhibits great potential in label-free biosensing. Full article
(This article belongs to the Section Optical Sensors)
Show Figures

Figure 1

46 pages, 7993 KiB  
Review
Quantum Dot-Based Luminescent Sensors: Review from Analytical Perspective
by Alissa Loskutova, Ansar Seitkali, Dinmukhamed Aliyev and Rostislav Bukasov
Int. J. Mol. Sci. 2025, 26(14), 6674; https://doi.org/10.3390/ijms26146674 - 11 Jul 2025
Viewed by 836
Abstract
Quantum Dots (QDs) are small semiconductor nanoparticles (<10 nm) with strong, relatively stable, and tunable luminescent properties, which are increasingly applied in the sensing and detection of various analytes, including metal ions, biomarkers, explosives, proteins, RNA/DNA fragments, pesticides, drugs, and pollutants. In this [...] Read more.
Quantum Dots (QDs) are small semiconductor nanoparticles (<10 nm) with strong, relatively stable, and tunable luminescent properties, which are increasingly applied in the sensing and detection of various analytes, including metal ions, biomarkers, explosives, proteins, RNA/DNA fragments, pesticides, drugs, and pollutants. In this review, we critically assess recent developments and advancements in luminescent QD-based sensors from an analytical perspective. We collected, tabulated, and analyzed relevant data reported in 124 peer-reviewed articles. The key analytical figures of merit, including the limit of detection (LOD), excitation and emission wavelengths, and size of the particles were extracted, tabulated, and analyzed with graphical representations. We calculated the geometric mean and median LODs from those tabulated publications. We found the following geometric mean LODs: 38 nM for QD-fluorescent-based sensors, 26 nM for QD-phosphorescent-based sensors, and an impressively low 0.109 pM for QD-chemiluminescent-based sensors, which demonstrate by far the best sensitivity in QD-based detection. Moreover, AI-based sensing methods, including the ATTBeadNet model, optimized principal component analysis(OPCA) model, and Support Vector Machine (SVM)-based system, were reviewed as they enhance the analytical performance of the detection. Despite these advances, there are still challenges that include improvements in recovery values, biocompatibility, stability, and overall performance. This review highlights trends to guide the future design of robust, high-performance, QD-based luminescent sensors. Full article
Show Figures

Figure 1

9 pages, 817 KiB  
Article
A Green and Simple Analytical Method for the Evaluation of the Effects of Zn Fertilization on Pecan Crops Using EDXRF
by Marcelo Belluzzi Muiños, Javier Silva, Paula Conde, Facundo Ibáñez, Valery Bühl and Mariela Pistón
Processes 2025, 13(7), 2218; https://doi.org/10.3390/pr13072218 - 11 Jul 2025
Viewed by 328
Abstract
A simple and fast analytical method was developed and applied to assess the effect of two forms of zinc fertilization on a pecan tree cultivar in Uruguay: fertigation and foliar application with a specially formulated fertilizer. Zinc content was determined in 36 leaf [...] Read more.
A simple and fast analytical method was developed and applied to assess the effect of two forms of zinc fertilization on a pecan tree cultivar in Uruguay: fertigation and foliar application with a specially formulated fertilizer. Zinc content was determined in 36 leaf samples from two crop cycles: 2020–2021 and 2021–2022. Fresh samples were dried, ground, and sieved. Analytical determinations were performed by flame atomic absorption spectrometry (FAAS, considered a standard method) and energy dispersive X-ray spectrometry (EDXRF, the proposed method). In the first case, sample preparation was carried out by microwave-assisted digestion using 4.5 mol L−1 HNO3. In the second case, pellets (Φ 13 mm, 2–3 mm thick) were prepared by direct mechanical pressing. Figures of merit of both methodologies were adequate for the purpose of zinc monitoring. The results obtained from both methodologies were statistically compared and found to be equivalent (95% confidence level). Based on the principles of Green Analytical Chemistry, both procedures were evaluated using the Analytical Greenness Metric Approach (AGREE and AGREEprep) tools. It was concluded that EDXRF was notably greener than FAAS and can be postulated as an alternative to the standard method. The information emerging from the analyses aided decision-making at the agronomic level. Full article
Show Figures

Figure 1

17 pages, 7561 KiB  
Article
Left-Hand Resonator VCO Using an Orthogonal Transformer
by Sheng-Lyang Jang, Yun-Chien Lee and Wen-Cheng Lai
Electronics 2025, 14(14), 2765; https://doi.org/10.3390/electronics14142765 - 9 Jul 2025
Cited by 1 | Viewed by 285
Abstract
Many novel microwave devices have been developed based on the left-handed (LH) structure. This paper studies three CMOS standing-wave oscillators (SWOs) using an LH LC network. The first SWO is a class-B VCO, and the second SWO is a class-C SWO. The SWOs [...] Read more.
Many novel microwave devices have been developed based on the left-handed (LH) structure. This paper studies three CMOS standing-wave oscillators (SWOs) using an LH LC network. The first SWO is a class-B VCO, and the second SWO is a class-C SWO. The SWOs are implemented with the TSMC 0.18 μm 1P6M CMOS process technology. The SWOs utilize two units of an LH LC resonator, and the LC resonator is shunted with a pair of cross-coupled transistors to compensate for the loss in the LC resonator. The first and second SWOs utilize two O-shaped inductors to form a unit cell with capacitors. The third SWO utilizes an eight-shaped inductor and an orthogonal transformer to conserve the die area and suppress the magnetic coupling noise. The die area of the third oscillator is 0.986 × 0.756 mm2. The SWO can generate differential signals in the frequency range of 8.3 GHz–9.3 GHz (10.83%), and its measured figure of merit (FOM) is −188.6 dBc/Hz at a 1 MHz offset frequency. Full article
(This article belongs to the Special Issue Advances in Frontend Electronics for Millimeter-Wave Systems)
Show Figures

Figure 1

14 pages, 2175 KiB  
Article
Engineering Ultra-Low Thermal Conductivity in (Pb0.8Ge0.2Te)0.95-x(PbSe)0.05(PbS)x Quaternary Lead Chalcogenides Through PbS-Induced Phase Segregation
by Dianta Ginting, Hadi Pronoto, Nurato, Kontan Tarigan, Sagir Alva, Muhamad Fitri, Dwi Nanto, Ai Nurlaela, Mashadi, Yunasfi, Toto Sudiro, Jumril Yunas and Jong-Soo Rhyee
Materials 2025, 18(14), 3232; https://doi.org/10.3390/ma18143232 - 9 Jul 2025
Viewed by 382
Abstract
The shortage of tellurium and toxicity of lead are major obstacles to scaling mid-temperature thermoelectric generators. We engineer quaternary lead chalcogenides with composition (Pb0.8Ge0.2Te)0.95-x(PbSe)0.05(PbS)x (0 ≤ x ≤ 0.25), where Pb is lead, [...] Read more.
The shortage of tellurium and toxicity of lead are major obstacles to scaling mid-temperature thermoelectric generators. We engineer quaternary lead chalcogenides with composition (Pb0.8Ge0.2Te)0.95-x(PbSe)0.05(PbS)x (0 ≤ x ≤ 0.25), where Pb is lead, Ge is germanium, Te is tellurium, Se is selenium, S is sulfur, and x denotes the molar fraction of lead sulfide (PbS). The primary novelty lies in achieving ultra-low thermal conductivity through controlled phase segregation induced by systematic PbS incorporation. X-ray diffraction analysis reveals single-phase solid solutions up to x ≈ 0.10, with secondary PbS precipitates forming beyond this threshold. These PbS-rich phases create hierarchical microstructures that scatter phonons across multiple length scales, suppressing total thermal conductivity to 0.6 Wm−1K−1 at x = 0.15—approximately 84% lower than pristine lead telluride (PbTe) and approaching glass-like thermal conductivity values. Electrical transport measurements demonstrate sulfur’s role as an electron donor, enabling carrier-type control from p-type to n-type conduction. Despite moderate electrical power factors, the optimized composition (x = 0.20) achieves a peak dimensionless figure of merit ZT ≈ 0.34 at 650 K. This work demonstrates an effective strategy for tellurium-lean, lead-reduced thermoelectric materials through sulfur-induced phase segregation, providing practical design guidelines for sustainable waste heat recovery applications. Full article
(This article belongs to the Section Energy Materials)
Show Figures

Figure 1

16 pages, 9957 KiB  
Article
Analysis and Optimization of Rotationally Symmetric Au-Ag Alloy Nanoparticles for Refractive Index Sensing Properties Using T-Matrix Method
by Long Cheng, Shuhong Gong and Paerhatijiang Tuersun
Nanomaterials 2025, 15(13), 1052; https://doi.org/10.3390/nano15131052 - 6 Jul 2025
Viewed by 377
Abstract
Previous investigations devoted to non-spherical nanoparticles for biosensing have primarily addressed two hot topics, namely, finding nanoparticles with the best shape for refractive index sensing properties and the optimization of size parameters. In this study, based on these hot topics, Au-Ag alloy nanoparticles [...] Read more.
Previous investigations devoted to non-spherical nanoparticles for biosensing have primarily addressed two hot topics, namely, finding nanoparticles with the best shape for refractive index sensing properties and the optimization of size parameters. In this study, based on these hot topics, Au-Ag alloy nanoparticles with excellent optical properties were selected as the research object. Targeting rotationally symmetric Au-Ag alloy nanoparticles for biosensing applications, the complex media function correction model and T-matrix approach were used to systematically analyze the variation patterns of extinction properties, refractive index sensitivity, full width at half maximum, and figure of merit of three rotationally symmetric Au-Ag alloy nanoparticles with respect to the size of the particles and the Au molar fraction. In addition, we optimized the figure of merit to obtain the best size parameters and Au molar fractions for the three rotationally symmetric Au-Ag alloy nanoparticles. Finally, the range of dimensional parameters corresponding to a figure of merit greater than 98% of its maximum value was calculated. The results show that the optimized Au-Ag alloy nanorods exhibit a refractive index sensitivity of 395.2 nm/RIU, a figure of merit of 7.16, and a wide range of size parameters. Therefore, the optimized Au-Ag alloy nanorods can be used as high-performance biosensors. Furthermore, this study provides theoretical guidance for the application and preparation of rotationally symmetric Au-Ag alloy nanoparticles in biosensing. Full article
(This article belongs to the Special Issue Theoretical Calculation Study of Nanomaterials: 2nd Edition)
Show Figures

Figure 1

17 pages, 15703 KiB  
Article
Improving of Thermoelectric Efficiency of Layered Sodium Cobaltite Through Its Doping by Different Metal Oxides
by Natalie S. Krasutskaya, Ekaterina A. Chizhova, Julia A. Zizika, Alexey V. Buka, Hongchao Wang and Andrei I. Klyndyuk
Ceramics 2025, 8(3), 86; https://doi.org/10.3390/ceramics8030086 - 5 Jul 2025
Viewed by 377
Abstract
Na0.89Co0.90Me0.10O2 (Me = Cr, Ni, Mo, W, Pb, and Bi) ceramic samples were prepared using a solid-state reaction method, and their crystal structure, microstructure, and electrical, thermal, and thermoelectric properties were investigated. The effect [...] Read more.
Na0.89Co0.90Me0.10O2 (Me = Cr, Ni, Mo, W, Pb, and Bi) ceramic samples were prepared using a solid-state reaction method, and their crystal structure, microstructure, and electrical, thermal, and thermoelectric properties were investigated. The effect of the nature of the doping metal (Me = Cr, Ni, Mo, W, and Bi) on the structure and properties of layered sodium cobaltite Na0.89CoO2 was analyzed. The largest Seebeck coefficient (616 μV/K at 1073 K) and figure-of-merit (1.74 at 1073 K) values among the samples studied were demonstrated by the Na0.89Co0.9Bi0.1O2 solid solution, which was also characterized by the lowest value of the dimensionless relative self-compatibility factor of about 8% within the 673–873 K temperature range. The obtained results demonstrate that doping of layered sodium cobaltite by transition and heavy metal oxides improves its microstructure and thermoelectric properties, which shows the prospectiveness of the used doping strategy for the development of new thermoelectric oxides with enhanced thermoelectric characteristics. It was also shown that samples with a higher sodium content (Na:Co = 0.89:1) possessed higher chemical and thermal stability than those with a lower sodium content (Na:Co = 0.55:1), which makes them more suitable for practical applications. Full article
Show Figures

Graphical abstract

13 pages, 5053 KiB  
Article
Thermoelectric Properties of NbCoNixSn (x = 0–1)
by Moritz Thiem, Ruijuan Yan, Anke Weidenkaff and Wenjie Xie
Materials 2025, 18(13), 3189; https://doi.org/10.3390/ma18133189 - 5 Jul 2025
Viewed by 451
Abstract
The half-Heusler (HH) compound NbCoSn, with 18 valence electrons, is a promising thermoelectric (TE) material due to its favourable electrical properties and excellent thermal and chemical stability. Enhancing its TE performance typically involves doping and microstructure engineering. In this study, Ni was introduced [...] Read more.
The half-Heusler (HH) compound NbCoSn, with 18 valence electrons, is a promising thermoelectric (TE) material due to its favourable electrical properties and excellent thermal and chemical stability. Enhancing its TE performance typically involves doping and microstructure engineering. In this study, Ni was introduced into NbCoSn to form NbCoNixSn (x = 0–1), and the effects of Ni content on the microstructure and TE properties were systematically investigated. At low doping levels (x ≤ 0.05), Ni occupies interstitial sites, forming NbCoNixSn solid solutions. At higher concentrations (x > 0.05), full-Heusler (FH) secondary phases emerge, resulting in HH–FH composites. The introduction of Co/Ni interstitials enhances TE performance by creating in-gap electronic states and increasing phonon scattering through point defects. A clear structural transition from HH to FH phases is observed with increasing Ni content. The highest figure of merit, ZT ≈ 0.52 at 975 K, was obtained for NbCoNi0.05Sn, comparable to the best values reported for this system. Full article
Show Figures

Figure 1

9 pages, 2068 KiB  
Article
Effects of Ge-Doping on Thermoelectric Performance of Polycrystalline Cubic Sn0.5Ag0.25Bi0.25Se0.50Te0.50
by Haoyu Zhao, Junliang Zhu, Zhonghe Zhu, Lin Bo, Wenying Wang, Xingshuo Liu, Changcun Li and Degang Zhao
Crystals 2025, 15(7), 622; https://doi.org/10.3390/cryst15070622 - 4 Jul 2025
Viewed by 254
Abstract
Cubic phase SnSe-based materials have great potential in the field of thermoelectricity due to their reduced carrier scattering, increased band degeneracy, and ultra-low lattice thermal conductivity. Nevertheless, systematic studies on the influence of element doping on the thermoelectric properties of cubic SnSe-based materials [...] Read more.
Cubic phase SnSe-based materials have great potential in the field of thermoelectricity due to their reduced carrier scattering, increased band degeneracy, and ultra-low lattice thermal conductivity. Nevertheless, systematic studies on the influence of element doping on the thermoelectric properties of cubic SnSe-based materials are still relatively scarce. To enrich the research in this field, this work investigates the effects of Ge doping on the phase composition, electrical and thermal transport properties of cubic Sn0.50Ag0.25Bi0.25Se0.50Te0.50 thermoelectric materials. X-ray diffraction (XRD) analysis confirmed that the Ge-doped samples exhibited a single cubic phase structure, while scanning electron microscopy (SEM) and energy-dispersive spectroscopy (EDS) revealed a uniform distribution of elements within the samples. The results indicate that increasing the Ge doping content substantially enhances their electrical conductivity, albeit at the expense of elevated thermal conductivity. By optimizing the content of Ge-doping, the thermoelectric figure of merit (ZT) reached 0.74 at 750 K. Notably, while moderate Ge doping enhances electrical transport properties, excessive doping leads to a significant rise in thermal conductivity, ultimately constraining further thermoelectric performance gains. Full article
Show Figures

Figure 1

Back to TopTop