Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (13)

Search Parameters:
Keywords = Au-Ge alloy

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
11 pages, 7517 KiB  
Article
Effect of Size on Phase Mixing Patterns in Rapidly Solidified Au–Ge Nanoparticles
by Olha Khshanovska, Vladyslav Ovsynskyi and Aleksandr Kryshtal
Nanomaterials 2025, 15(12), 924; https://doi.org/10.3390/nano15120924 - 14 Jun 2025
Viewed by 416
Abstract
We investigated the morphological patterns, crystalline structures and their thermal stability in solidified Au–Ge nanoparticles ranging in size from 10 to 500 nm. Liquid Au–Ge alloy nanoparticles with hypoeutectic composition were rapidly cooled from a temperature of 500 °C in a TEM and [...] Read more.
We investigated the morphological patterns, crystalline structures and their thermal stability in solidified Au–Ge nanoparticles ranging in size from 10 to 500 nm. Liquid Au–Ge alloy nanoparticles with hypoeutectic composition were rapidly cooled from a temperature of 500 °C in a TEM and characterized using advanced TEM techniques. We demonstrated that Au–Ge nanoparticles 10–80 nm in size predominantly solidified into a Janus-like morphology with nearly pure single-crystalline hcp Au and diamond cubic Ge domains. These particles remained stable up to the eutectic temperature, indicating that Ge doping and particle size play key roles in stabilizing the hcp Au phase. In turn, larger nanoparticles exhibited a metastable core–shell morphology with polycrystalline Ge shell and hcp Au-Ge alloy core under solidification. It was shown that the mentioned morphology and crystalline structure evolved into the equilibrium Janus morphology with fcc Au and diamond Ge domains at temperatures above ≈160 °C. Full article
(This article belongs to the Special Issue Nanoscale Microscopy Techniques for Energy Materials)
Show Figures

Graphical abstract

19 pages, 12021 KiB  
Article
The Thermomechanical, Functional and Biocompatibility Properties of a Au–Pt–Ge Alloy for PFM Dental Restorations
by Peter Majerič, Minja Miličić Lazić, Dijana Mitić, Marko Lazić, Ema Krdžović Lazić, Gyöngyi Vastag, Ivan Anžel, Vojkan Lazić and Rebeka Rudolf
Materials 2024, 17(22), 5491; https://doi.org/10.3390/ma17225491 - 10 Nov 2024
Viewed by 1686
Abstract
A high-noble Au–Pt–Ge porcelain-fused-to-metal (PFM) dental alloy without the known adverse metallic elements and with the addition of germanium (Ge) was produced as a more cost-effective alternative to other precious alloying metals, with investigations for determining the functionality and clinical use of this [...] Read more.
A high-noble Au–Pt–Ge porcelain-fused-to-metal (PFM) dental alloy without the known adverse metallic elements and with the addition of germanium (Ge) was produced as a more cost-effective alternative to other precious alloying metals, with investigations for determining the functionality and clinical use of this alloy. The thermomechanical, biocompatibility, durability, workability and economic characteristics of the produced dental alloy were investigated. These properties were investigated with in vitro biocompatibility testing on human gingival fibroblasts (HGFs); static immersion testing for metal ion release; DSC analysis; hardness, tensile testing, density and coefficient of thermal expansion (CTE) measurements; metallographic and SEM/EDX microstructure investigations; and finally with the production of a test PFM dental bridge. The results of the thermomechanical testing showed alloy properties suitable for dental restorations and clinical use, with somewhat lower mechanical properties, making the alloy not suitable for extensive multiunit fixed restorations. The microstructure investigations showed segregations of Ge in the homogeneous alloy matrix, which reduce the alloy’s mechanical properties. The produced PFM dental bridge showed excellent workability of the alloy in a dental laboratory setting, as well as a high standard of the final dental restoration. The ion release was negligible, well below any harmful quantities, while the cell viability examination showed significantly higher viability ratings on polished alloy samples as compared to as-cast samples. The results showed that a dental substructure in direct contact with oral tissue and fluids should be highly polished. The performed investigations showed that the produced PFM dental alloy is suitable for clinical use in producing high-quality dental restorations with high biocompatibility for patients prone to metal allergies. Full article
(This article belongs to the Section Biomaterials)
Show Figures

Graphical abstract

13 pages, 3441 KiB  
Article
Electrochemical Behaviour of an Au-Ge Alloy in an Artificial Saliva and Sweat Solution
by Gyöngyi Vastag, Peter Majerič, Vojkan Lazić and Rebeka Rudolf
Metals 2024, 14(6), 668; https://doi.org/10.3390/met14060668 - 5 Jun 2024
Cited by 1 | Viewed by 1198
Abstract
In modern times, more and more different materials (including alloys) are in direct contact with human electrolytes (sweat, saliva, lymph, blood, etc.). One of the most important properties for the use of these materials is therefore their chemical inertness or resistance to corrosion [...] Read more.
In modern times, more and more different materials (including alloys) are in direct contact with human electrolytes (sweat, saliva, lymph, blood, etc.). One of the most important properties for the use of these materials is therefore their chemical inertness or resistance to corrosion when they are in contact with human electrolytes. Consequently, during the development of such new materials, it is necessary to study and understand their basic electrochemical behaviour in a given environment. The purpose of this research was to monitor the electrochemical behaviour of the new Au-Ge alloy in artificial sweat and artificial saliva solutions, depending on the electrolyte composition and exposure time. This new alloy represents a potential material for use in dentistry or for jewellery. The obtained results of the study show that the immersion time and the pH value have a significantly greater influence on the corrosion resistance of the new Au-Ge alloy than the composition of the electrolyte solution. The results of the SEM/EDX analysis additionally confirm the main results of the electrochemical measurements. Full article
(This article belongs to the Special Issue Feature Papers in Extractive Metallurgy)
Show Figures

Figure 1

17 pages, 5887 KiB  
Article
Thermodynamic Modeling of the Au-Ge-X (X = In, Sb, Si, Zn) Ternary Systems
by Yuchen Bai, Qingsong Tong, Maohua Rong, Cong Tan, Xingyu Liu, Man Li and Jiang Wang
Materials 2024, 17(9), 2137; https://doi.org/10.3390/ma17092137 - 2 May 2024
Cited by 1 | Viewed by 1057
Abstract
In this study, the CALPHAD approach was employed to model the thermodynamics of the Au-Ge-X (X = In, Sb, Si, Zn) ternary systems, leveraging experimental phase equilibria data and previous assessments of related binary subsystems. The solution phases were modeled as substitutional solutions, [...] Read more.
In this study, the CALPHAD approach was employed to model the thermodynamics of the Au-Ge-X (X = In, Sb, Si, Zn) ternary systems, leveraging experimental phase equilibria data and previous assessments of related binary subsystems. The solution phases were modeled as substitutional solutions, and their excess Gibbs energies were expressed using the Redlich–Kister polynomial. Owing to the unavailability of experimental data, the solubility of the third elements in the Au-In, Au-Sb, and Au-Zn binary intermetallic compounds was excluded from consideration. Additionally, stable ternary intermetallic compounds were not reported in the literature and, thus, were not taken into account in the present thermodynamic calculations. Calculations of liquidus projections, isothermal sections, and vertical sections for these ternary systems have been performed, aligning with existing experimental findings. These thermodynamic parameters form a vital basis for creating a comprehensive thermodynamic database for Au-Ge-based alloys, which is essential for the design and development of new high-temperature Pb-free solders. Full article
Show Figures

Figure 1

16 pages, 14850 KiB  
Article
Tuning the Liquid–Vapour Interface of VLS Epitaxy for Creating Novel Semiconductor Nanostructures
by Galih R. Suwito, Vladimir G. Dubrovskii, Zixiao Zhang, Weizhen Wang, Sofiane Haffouz, Dan Dalacu, Philip J. Poole, Peter Grutter and Nathaniel J. Quitoriano
Nanomaterials 2023, 13(5), 894; https://doi.org/10.3390/nano13050894 - 27 Feb 2023
Cited by 1 | Viewed by 2030
Abstract
Controlling the morphology and composition of semiconductor nano- and micro-structures is crucial for fundamental studies and applications. Here, Si-Ge semiconductor nanostructures were fabricated using photolithographically defined micro-crucibles on Si substrates. Interestingly, the nanostructure morphology and composition of these structures are strongly dependent on [...] Read more.
Controlling the morphology and composition of semiconductor nano- and micro-structures is crucial for fundamental studies and applications. Here, Si-Ge semiconductor nanostructures were fabricated using photolithographically defined micro-crucibles on Si substrates. Interestingly, the nanostructure morphology and composition of these structures are strongly dependent on the size of the liquid–vapour interface (i.e., the opening of the micro-crucible) in the CVD deposition step of Ge. In particular, Ge crystallites nucleate in micro-crucibles with larger opening sizes (3.74–4.73 μm2), while no such crystallites are found in micro-crucibles with smaller openings of 1.15 μm2. This interface area tuning also results in the formation of unique semiconductor nanostructures: lateral nano-trees (for smaller openings) and nano-rods (for larger openings). Further TEM imaging reveals that these nanostructures have an epitaxial relationship with the underlying Si substrate. This geometrical dependence on the micro-scale vapour–liquid–solid (VLS) nucleation and growth is explained within a dedicated model, where the incubation time for the VLS Ge nucleation is inversely proportional to the opening size. The geometric effect on the VLS nucleation can be used for the fine tuning of the morphology and composition of different lateral nano- and micro-structures by simply changing the area of the liquid–vapour interface. Full article
Show Figures

Graphical abstract

10 pages, 2092 KiB  
Communication
Electrical and Structural Properties of Si1−xGex Nanowires Prepared from a Single-Source Precursor
by Raphael Behrle, Vanessa Krause, Michael S. Seifner, Benedikt Köstler, Kimberly A. Dick, Matthias Wagner, Masiar Sistani and Sven Barth
Nanomaterials 2023, 13(4), 627; https://doi.org/10.3390/nano13040627 - 4 Feb 2023
Cited by 4 | Viewed by 2469
Abstract
Si1−xGex nanowires (NWs) were prepared by gold-supported chemical vapor deposition (CVD) using a single-source precursor with preformed Si–Ge bonds. Besides the tamed reactivity of the precursor, the approach reduces the process parameters associated with the control of decomposition characteristics [...] Read more.
Si1−xGex nanowires (NWs) were prepared by gold-supported chemical vapor deposition (CVD) using a single-source precursor with preformed Si–Ge bonds. Besides the tamed reactivity of the precursor, the approach reduces the process parameters associated with the control of decomposition characteristics and the dosing of individual precursors. The group IV alloy NWs are single crystalline with a constant diameter along their axis. During the wire growth by low pressure CVD, an Au-containing surface layer on the NWs forms by surface diffusion from the substrate, which can be removed by a combination of oxidation and etching. The electrical properties of the Si1−xGex/Au core-shell NWs are compared to the Si1−xGex NWs after Au removal. Core–shell NWs show signatures of metal-like behavior, while the purely semiconducting NWs reveal typical signatures of intrinsic Si1−xGex. The synthesized materials should be of high interest for applications in nano- and quantum-electronics. Full article
Show Figures

Figure 1

11 pages, 2838 KiB  
Article
Development of a New AuCuZnGe Alloy and Determination of Its Corrosion Properties
by Rebeka Rudolf, Peter Majerič, Vojkan Lazić and Branimir Grgur
Metals 2022, 12(8), 1284; https://doi.org/10.3390/met12081284 - 30 Jul 2022
Cited by 4 | Viewed by 1919
Abstract
In this paper, we present the idea and development of a new gold-copper-zinc-germanium (AuCuZnGe) alloy, which is related to the method of production and research of its key properties, so that the new Au alloy could be used for jewelry production and in [...] Read more.
In this paper, we present the idea and development of a new gold-copper-zinc-germanium (AuCuZnGe) alloy, which is related to the method of production and research of its key properties, so that the new Au alloy could be used for jewelry production and in dental technology. The research design was associated with the determination of appropriate chemical composition, manufacturing technology, and performing the characterization. Melting and casting technologies were used to cast the AuCuZnGe alloy while rolling was used to prepare the cylinders and cutting to make square plates with a = 10 mm and thickness of 1 mm. Such plates were provided for corrosion testing. Observation of the plate′s microstructure was performed with Scanning Electron Microscopy (SEM) equipped by Energy-Dispersive X-ray spectrometry (EDS) and X-ray diffraction (XRD). Corrosion testing involved performing the following measurements: Polarization, the open circuit potentials, and linear polarization resistance. Based on the SEM, EDS, XRD, and results of corrosion testing it can be concluded that the new AuCuZnGe alloy possesses high corrosion stability and can be classified as a high noble alloy. Full article
(This article belongs to the Special Issue Applications of Electrochemistry in Corrosion Science and in Practice)
Show Figures

Figure 1

11 pages, 2708 KiB  
Article
Enhanced Performance and Diffusion Robustness of Phase-Change Metasurfaces via a Hybrid Dielectric/Plasmonic Approach
by Joe Shields, Carlota Ruiz de Galarreta, Jacopo Bertolotti and C. David Wright
Nanomaterials 2021, 11(2), 525; https://doi.org/10.3390/nano11020525 - 18 Feb 2021
Cited by 11 | Viewed by 5171
Abstract
Materials of which the refractive indices can be thermally tuned or switched, such as in chalcogenide phase-change alloys, offer a promising path towards the development of active optical metasurfaces for the control of the amplitude, phase, and polarization of light. However, for phase-change [...] Read more.
Materials of which the refractive indices can be thermally tuned or switched, such as in chalcogenide phase-change alloys, offer a promising path towards the development of active optical metasurfaces for the control of the amplitude, phase, and polarization of light. However, for phase-change metasurfaces to be able to provide viable technology for active light control, in situ electrical switching via resistive heaters integral to or embedded in the metasurface itself is highly desirable. In this context, good electrical conductors (metals) with high melting points (i.e., significantly above the melting point of commonly used phase-change alloys) are required. In addition, such metals should ideally have low plasmonic losses, so as to not degrade metasurface optical performance. This essentially limits the choice to a few noble metals, namely, gold and silver, but these tend to diffuse quite readily into phase-change materials (particularly the archetypal Ge2Sb2Te5 alloy used here), and into dielectric resonators such as Si or Ge. In this work, we introduce a novel hybrid dielectric/plasmonic metasurface architecture, where we incorporated a thin Ge2Sb2Te5 layer into the body of a cubic silicon nanoresonator lying on metallic planes that simultaneously acted as high-efficiency reflectors and resistive heaters. Through systematic studies based on changing the configuration of the bottom metal plane between high-melting-point diffusive and low-melting-point nondiffusive metals (Au and Al, respectively), we explicitly show how thermally activated diffusion can catastrophically and irreversibly degrade the optical performance of chalcogenide phase-change metasurface devices, and how such degradation can be successfully overcome at the design stage via the incorporation of ultrathin Si3N4 barrier layers between the gold plane and the hybrid Si/Ge2Sb2Te5 resonators. Our work clarifies the importance of diffusion of noble metals in thermally tunable metasurfaces and how to overcome it, thus helping phase-change-based metasurface technology move a step closer towards the realization of real-world applications. Full article
(This article belongs to the Section Nanophotonics Materials and Devices)
Show Figures

Graphical abstract

13 pages, 9155 KiB  
Article
Effects of Extreme Thermal Shock on Microstructure and Mechanical Properties of Au-12Ge/Au/Ni/Cu Solder Joint
by Ziyi Wang, Songbai Xue, Weimin Long, Bo Wang, Jianhao Wang and Peng Zhang
Metals 2020, 10(10), 1373; https://doi.org/10.3390/met10101373 - 15 Oct 2020
Cited by 7 | Viewed by 2975
Abstract
Extreme temperature change has generally been the great challenge to spacecraft electronic components, particularly in long, periodic, deep-space exploration missions. Hence, researchers have paid more attention to the reliability of component packaging materials. In this study, the microstructure evolution on the interface of [...] Read more.
Extreme temperature change has generally been the great challenge to spacecraft electronic components, particularly in long, periodic, deep-space exploration missions. Hence, researchers have paid more attention to the reliability of component packaging materials. In this study, the microstructure evolution on the interface of Cu/Ni/Au/Au-12Ge/Au/Ni/Cu joints, as well as the effects of extreme thermal shock on mechanical properties and the fracture mode in the course of extreme thermal changes between −196 and 150 °C, have been investigated. Results revealed that the interface layers comprised of two thin layers of NiGe and Ni5Ge3 compounds after Au-12Ge solder alloy was soldered on the Au/Ni/Cu substrate. After extreme thermal shock tests, the microstructure morphology converted from scallop type to planar one due to the translation from NiGe to Ni5Ge3. Meanwhile, the thickness of interface layer hardly changed. The shear strength of the joints after 300 cycles of extreme thermal shock was 35.1 MPa, which decreased by 19.61%. The fracture location changed from the solder to solder/NiGe interface, and then to the interface of NiGe/Ni5Ge3 IMC layer. Moreover, the fracture type of the joints gradually transformed from ductile fracture mode to brittle mode during thermal shock test. Simultaneously, the formation and extension of defects, such as micro-voids and micro-cracks, were found during the process of thermal shock due to the different thermal expansion coefficient among the solder, interface layer and substrate. Full article
Show Figures

Figure 1

13 pages, 10428 KiB  
Article
Thermochemical Route for Extraction and Recycling of Critical, Strategic and High Value Elements from By-Products and End-of-Life Materials, Part I: Treatment of a Copper By-Product in Air Atmosphere
by Ndue Kanari, Eric Allain, Seit Shallari, Frederic Diot, Sebastien Diliberto, Fabrice Patisson and Jacques Yvon
Materials 2019, 12(10), 1625; https://doi.org/10.3390/ma12101625 - 17 May 2019
Cited by 19 | Viewed by 4176
Abstract
Development of our modern society requests a number of critical and strategic elements (platinum group metals, In, Ga, Ge…) and high value added elements (Au, Ag, Se, Te, Ni…) which are often concentrated in by-products during the extraction of base metals (Cu, Pb, [...] Read more.
Development of our modern society requests a number of critical and strategic elements (platinum group metals, In, Ga, Ge…) and high value added elements (Au, Ag, Se, Te, Ni…) which are often concentrated in by-products during the extraction of base metals (Cu, Pb, Zn…). Further, recycling of end-of-life materials employed in high technology, renewable energy and transport by conventional extractive processes also leads to the concentration of such chemical elements and their compounds in metallurgical by-products and/or co-products. One of these materials, copper anode slime (CAS), derived from a copper electrolytic refining factory, was used for this study. The sample was subjected to isothermal treatment from 225 to 770 °C under air atmosphere and the reaction products were systematically analyzed by scanning electron microscopy through energy dispersive spectroscopy (SEM-EDS) and X-ray diffraction (XRD) to investigate the thermal behavior of the treated sample. The main components of the anode slime (CuAgSe, Cu2-xSeyS1-y, Ag3AuSe2) react with oxygen, producing mostly copper and selenium oxides as well as Ag-Au alloys as final products at temperatures higher than 500 °C. Selenium dioxide (SeO2) is volatilized and recovered in pure state by cooling the gaseous phase, whilst copper(II) oxide, silver, gold and tellurium remain in the treatment residue. Full article
(This article belongs to the Special Issue Characterization and Processing of Complex Materials)
Show Figures

Figure 1

11 pages, 3032 KiB  
Article
Thermoelectric Properties of Thin Films of Germanium-Gold Alloy Obtained by Magnetron Sputtering
by Damian Nowak, Marta Turkiewicz and Natalia Solnica
Coatings 2019, 9(2), 120; https://doi.org/10.3390/coatings9020120 - 15 Feb 2019
Cited by 9 | Viewed by 5050
Abstract
In this paper, the electric and thermoelectric properties of thin films of germanium–gold alloy (Ge–Au) are discussed in terms of choosing the optimal deposition process and post-processing conditions to obtain Ge–Au layers with the best thermoelectric parameters. Thin films were fabricated by magnetron [...] Read more.
In this paper, the electric and thermoelectric properties of thin films of germanium–gold alloy (Ge–Au) are discussed in terms of choosing the optimal deposition process and post-processing conditions to obtain Ge–Au layers with the best thermoelectric parameters. Thin films were fabricated by magnetron sputtering using the Ge–Au alloy target onto glass substrates at two various conditions; during one of the sputtering processes, the external substrate bias voltage (Ub = −150 V) was used. After deposition thin films were annealed in the atmosphere of N2 at various temperatures (473, 523 and 573 K) to investigate the influence of annealing temperature on the electric and thermoelectric properties of films. Afterwards, the thermocouples were created by deposition of the NiCrSi/Ag contact pads onto Ge–Au films. In this work, particular attention has been paid to thermoelectric properties of fabricated thin films—the thermoelectric voltage, Seebeck coefficient, power factor PF and dimensionless figure of merit ZT were determined. Full article
(This article belongs to the Special Issue Novel Thin Film Materials for Thermoelectric Applications)
Show Figures

Figure 1

11 pages, 4287 KiB  
Article
Effects of Au and Ge Additions on the Microstructures and Properties of Ag-1.5Cu-0.1Y Alloys
by Desheng Zhang, Qin Zhang, Sida Li and Hongying Yang
Materials 2019, 12(1), 123; https://doi.org/10.3390/ma12010123 - 2 Jan 2019
Cited by 2 | Viewed by 2694
Abstract
The application of silver is seriously affected by its tendency to oxidize and corrode. Therefore, the addition of proper alloying elements to silver-based alloys to achieve better properties has become a hot topic at present. In this current study, the effects of the [...] Read more.
The application of silver is seriously affected by its tendency to oxidize and corrode. Therefore, the addition of proper alloying elements to silver-based alloys to achieve better properties has become a hot topic at present. In this current study, the effects of the addition of the two elements Au and Ge on the microstructures and properties of Ag-1.5Cu-0.1Y alloys were investigated. The results showed that the microstructures were refined and the second dendrite was shortened in the Ag-1.5Cu-0.1Y alloys with the addition of Au and Ge. Adding Au enhanced the corrosion resistance of the Ag-1.5Cu-0.1Y alloys. Furthermore, the corrosion resistance of the Ag-1.5Cu-0.1Y alloys with the addition of both Ge and Au was better than that of the alloy samples with Au added alone. The best corrosion resistance of the Ag-1.5Cu-0.1Y alloys was achieved by adding 1.0 wt.% Au and 1.0 wt.% Ge. The microhardness was enhanced by the addition of Au and Ge, and was strongly correlated with the secondary dendrite arm spacing (λ2) of the Ag-1.5Cu-0.1Y alloys. In addition, the Au addition could improve the conductivity of the Ag-1.5Cu-0.1Y alloy; however, Ge had little effect on the conductivity of the alloy samples. This work provides an experimental basis for the design of better performing silver-based alloys. Full article
Show Figures

Figure 1

14 pages, 10517 KiB  
Article
Interfacial Microstructure and Shear Strength of Brazed Cu-Cr-Zr Alloy Cylinder and Cylindrical Hole by Au Based Solder
by Zaihua Li, Youping Yi, Diqiu He and Ruilin Lai
Metals 2017, 7(7), 247; https://doi.org/10.3390/met7070247 - 3 Jul 2017
Cited by 6 | Viewed by 4346
Abstract
Au-Ge-Ni solder was chosen for brazing of the Cu-Cr-Zr alloy cylinder and a part with a cylindrical hole (sleeve) below 550 °C. The Au based solder was first sintered on the surface of the cylinder and then brazed to the inner surface of [...] Read more.
Au-Ge-Ni solder was chosen for brazing of the Cu-Cr-Zr alloy cylinder and a part with a cylindrical hole (sleeve) below 550 °C. The Au based solder was first sintered on the surface of the cylinder and then brazed to the inner surface of the sleeve. The effects of the heating process, the temperature and the holding time at the temperature on the microstructure of the sintered layer on the surface of the cylinder, the brazed interfacial microstructure, and the brazed shear strength between the cylinder and the sleeve were investigated by scanning electron microscope, energy dispersive X-ray spectroscopy analysis, and tensile shear tests. By approach of side solder melt feeding and brazing under proper parameters, the voids and micro cracks due to a lack of enough solder melt feeding are greatly lessened and the brazed shear strength of 100 MPa is ensured even with large clearances around 0.01 mm. Full article
Show Figures

Figure 1

Back to TopTop