Previous Issue
Volume 3, March
 
 

Hardware, Volume 3, Issue 2 (June 2025) – 2 articles

  • Issues are regarded as officially published after their release is announced to the table of contents alert mailing list.
  • You may sign up for e-mail alerts to receive table of contents of newly released issues.
  • PDF is the official format for papers published in both, html and pdf forms. To view the papers in pdf format, click on the "PDF Full-text" link, and use the free Adobe Reader to open them.
Order results
Result details
Select all
Export citation of selected articles as:
6 pages, 5351 KiB  
Communication
A 3D Printed, Time-Resolved, Settle-Plate Air Sampler
by Jonathan E. Thompson
Hardware 2025, 3(2), 4; https://doi.org/10.3390/hardware3020004 - 16 May 2025
Viewed by 61
Abstract
A novel temporally resolved settle-plate air sampler was developed using 3D printing technology to improve upon traditional passive air sampling methods. Conventional settle plates provide cumulative measurements of particle or microbial loads over an entire sampling period, lacking the temporal resolution necessary to [...] Read more.
A novel temporally resolved settle-plate air sampler was developed using 3D printing technology to improve upon traditional passive air sampling methods. Conventional settle plates provide cumulative measurements of particle or microbial loads over an entire sampling period, lacking the temporal resolution necessary to identify specific contamination events. The described device integrates a petri plate within a 3D-printed housing featuring a narrow slit that exposes only a small portion of the plate to incoming particles. A rotary mechanism, driven by a mechanical clock motor, rotates the petri plate over 12 h, allowing for time-segmented sampling. Validation experiments demonstrated the device’s ability to accurately encode the temporal history of particle deposition using both aerosolized dyes and viable microbial spores. The device effectively correlated bioaerosol deposition with ambient wind conditions during outdoor sampling. The system is inexpensive (under USD 10), requires no specialized skills to assemble, and is compatible with existing settle plate methodologies. This innovation enhances the ability to conduct air quality assessments in critical environments, enabling data-driven decisions to mitigate contamination risks. Full article
Show Figures

Figure 1

14 pages, 1670 KiB  
Article
Design of the New Foot Psychomotor Vigilance Test (PVT) for Screening Driving Ability
by Yutaka Yoshida, Emi Yuda and Kiyoko Yokoyama
Hardware 2025, 3(2), 3; https://doi.org/10.3390/hardware3020003 - 8 Apr 2025
Viewed by 379
Abstract
The ability to respond swiftly and accurately to visual stimuli is critical for safe driving. The traditional Psychomotor Vigilance Test (PVT) primarily assesses response time (RT) using finger inputs, but these do not directly evaluate foot responses essential for vehicle control. This study [...] Read more.
The ability to respond swiftly and accurately to visual stimuli is critical for safe driving. The traditional Psychomotor Vigilance Test (PVT) primarily assesses response time (RT) using finger inputs, but these do not directly evaluate foot responses essential for vehicle control. This study introduces a novel Foot Psychomotor Vigilance Test (Foot PVT) designed to measure the RTs of the foot in response to simulated traffic lights. The Foot PVT integrates a traffic light display interface with a three-pedal system, simulating basic driving conditions. RTs are recorded for three colors (blue, yellow, red) displayed in a randomized order, and the response accuracy is evaluated based on the pedal input. The system also measures correction times for errors, offering insights into a driver’s ability to recover from mistakes. Validation experiments were conducted with eleven healthy younger (25 ± 3 years) and eleven healthy older adult participants (73 ± 4 years). The results showed that the older adult participants (818 ± 84 ms) exhibited significantly longer RTs than the younger participants (725 ± 74 ms, p = 0.016), consistent with age-related cognitive and motor decline. Interestingly, the older participants had fewer false starts, suggesting a compensatory cautious approach to responding. The Foot PVT has the potential to serve as a low-cost, efficient screening tool for evaluating driving fitness, particularly for older adult individuals and novice drivers. Full article
Show Figures

Figure 1

Previous Issue
Back to TopTop