You are currently viewing a new version of our website. To view the old version click .
Proceedings
  • Abstract
  • Open Access

8 December 2017

Impact of Poly(3-hexylthiophene) Chains Length and Other Applied Side-Chains on the Sensitivity of Gas Sensors Based on Conducting Graft Copolymers †

,
and
1
Department of Optoelectronics, Silesian University of Technology, 2 Krzywoustego St., 44-100 Gliwice, Poland
2
Department of Physical Chemistry and Technology of Polymers, Silesian University of Technology, 9 Strzody St., 44-100 Gliwice, Poland
*
Author to whom correspondence should be addressed.
Presented at the 5th International Symposium on Sensor Science (I3S 2017), Barcelona, Spain, 27–29 September 2017.
This article belongs to the Proceedings Proceedings of the 5th International Symposium on Sensor Science (I3S 2017)
In this work, novel conducting graft copolymers: DodecSil (Poly(dimetylesiloksane)-co-[poly(metylhydrosiloksane)-graft-2-winyl-poly(3-heksylthiophene)]-co-[poly(dimetylsiloksane)-graft-dodec-1-en]) and PEGSil (Poly(dimetylsiloksan)-co-[poli(metylohydrosiloksane)-graft-2-winyl-poly(3-heksylthiophene)]-co-[poly(dimetylsiloksane)-graft-metakrylane ethere metylene poly(etylene glicole)]) were tested as gas receptor thin films in resistance gas sensors. For both graft copolymers, two variants were tested: fractions with shorter (hexane fraction-H) and longer (chloroform fraction-CH) side-chains of P3HT. Sensors were obtained using the spin coating method on interdigital transducers (Au on Si/SiO2). Sensor responses to NO2 (1–20 ppm) were tested and compared. Experiments were carried out in the dry nitrogen atmosphere at different operating temperatures (room temperature (RT), 50 °C and 100 °C). Results showed that both copolymers with PEG side-chines had higher response to NO2 than materials with dodec-1-en side-chains. What is more, results showed that in both cases hexane fractions are more sensitive than chloroform fractions. Measured responses (Ra/Rg·100%) to 1 ppm of NO2 at RT are: 250% DodecSIL-CH, 460% DodecSIL-H, 600% PEGSil-Ch and 1330% PEGSil-H. Similarly, in other operating temperatures, PEGSil film responses were higher than DodecSil ones, and H fractions were more sensitive than CH fractions. This showed that graft copolymers of P3HT have a huge potential for low temperature NO2 sensing, and the proper choice of other side-chains can improve their sensing properties.

Conflicts of Interest

The authors declare no conflict of interest.
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.