Scientia Pharmaceutica is published by MDPI from Volume 84 Issue 3 (2016). Previous articles were published by another publisher in Open Access under a CC-BY (or CC-BY-NC-ND) licence, and they are hosted by MDPI on mdpi.com as a courtesy and upon agreement with Austrian Pharmaceutical Society (Österreichische Pharmazeutische Gesellschaft, ÖPhG).
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Potentiometric Flow Injection Analysis of Bromhexine Hydrochloride and its Pharmaceutical Preparation Using Conventional and Coated Wire Ion-Selective Electrodes

by
Nour T. Abdel-Ghani
*,
Yousry M. Issa
and
Howayda M. Ahmed
Chemistry Department, Faculty of Science, Cairo University, Giza, Egypt.
*
Author to whom correspondence should be addressed.
Sci. Pharm. 2006, 74(3), 121-135; https://doi.org/10.3797/scipharm.2006.74.121
Submission received: 3 November 2005 / Accepted: 16 February 2006 / Published: 30 September 2006

Abstract

Bromhexine hydrochloride ion-selective electrodes (conventional type) based on bromhexinium tetraphenyl borate (I) and bromhexinium-phosphotungstate (II) were prepared. The electrodes exhibited mean slopes of calibration graphs of 59.4 mV and 59.8 mV per decade of bromhexine concentration at 25°C for electrode (I) and (II), respectively. Both electrodes could be used within the concentration range 3.16x10-5-1.00x10-2 M bromhexine within the pH range 2.0-4.5. The standard electrodes potentials were determined at different temperatures and used to calculate the isothermal coefficients of the electrodes, which were 0.00065 and 0.00050 V°C-1 for (I) and (II), respectively. The electrodes showed a very good selectivity for bromhexine with respect to a number of inorganic cations, amino acids and sugars. The electrodes were applied to the potentiometric determination of bromhexine hydrochloride and its pharmaceutical preparation under batch and flow injection conditions. Graphite, copper and silver coated wires were prepared, characterized and successfully applied as sensors for the drug under investigation.
Keywords: Ion-selective electrodes; bromhexine hydrochloride; conventional and coated wire electrodes; flow injection analysis and conductimetry Ion-selective electrodes; bromhexine hydrochloride; conventional and coated wire electrodes; flow injection analysis and conductimetry

Share and Cite

MDPI and ACS Style

Abdel-Ghani, N.T.; Issa, Y.M.; Ahmed, H.M. Potentiometric Flow Injection Analysis of Bromhexine Hydrochloride and its Pharmaceutical Preparation Using Conventional and Coated Wire Ion-Selective Electrodes. Sci. Pharm. 2006, 74, 121-135. https://doi.org/10.3797/scipharm.2006.74.121

AMA Style

Abdel-Ghani NT, Issa YM, Ahmed HM. Potentiometric Flow Injection Analysis of Bromhexine Hydrochloride and its Pharmaceutical Preparation Using Conventional and Coated Wire Ion-Selective Electrodes. Scientia Pharmaceutica. 2006; 74(3):121-135. https://doi.org/10.3797/scipharm.2006.74.121

Chicago/Turabian Style

Abdel-Ghani, Nour T., Yousry M. Issa, and Howayda M. Ahmed. 2006. "Potentiometric Flow Injection Analysis of Bromhexine Hydrochloride and its Pharmaceutical Preparation Using Conventional and Coated Wire Ion-Selective Electrodes" Scientia Pharmaceutica 74, no. 3: 121-135. https://doi.org/10.3797/scipharm.2006.74.121

APA Style

Abdel-Ghani, N. T., Issa, Y. M., & Ahmed, H. M. (2006). Potentiometric Flow Injection Analysis of Bromhexine Hydrochloride and its Pharmaceutical Preparation Using Conventional and Coated Wire Ion-Selective Electrodes. Scientia Pharmaceutica, 74(3), 121-135. https://doi.org/10.3797/scipharm.2006.74.121

Article Metrics