Next Article in Journal
A Method for Studying Building Color Harmony in Coastal Historic and Cultural Districts: A Case Study of Mojiko, Japan
Next Article in Special Issue
Flexural Behavior of Concrete Slabs Reinforced with Embedded 3D Steel Trusses
Previous Article in Journal
Safety Risk Assessment of Jacking Renovation Construction for Aging Bridges Based on DBN and Fuzzy Set Theory
Previous Article in Special Issue
Residual Stress Distribution and Fatigue Behavior of Combined Bolted–Welded Joints
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Experimental Investigation of the Confinement of Concrete Columns with Welded Wire Reinforcement

1
Materials Science and Engineering Program, College of Arts and Sciences, American University of Sharjah, Sharjah 26666, United Arab Emirates
2
Department of Civil Engineering, College of Engineering, American University of Sharjah, Sharjah 26666, United Arab Emirates
*
Author to whom correspondence should be addressed.
Buildings 2025, 15(9), 1494; https://doi.org/10.3390/buildings15091494
Submission received: 14 March 2025 / Revised: 26 April 2025 / Accepted: 27 April 2025 / Published: 28 April 2025
(This article belongs to the Special Issue Experimental and Theoretical Studies on Steel and Concrete Structures)

Abstract

Traditional methods of construction for reinforced concrete columns utilize longitudinal steel bars and transverse ties. Field experience has shown that such a transverse reinforcement method is labor-intensive, time-consuming, and prone to inconsistencies in quality. Welded wire reinforcement (WWR) offers a prefabricated alternative, forming a closed cage that simplifies installation and speeds up the fabrication process. This study investigates the potential of using WWR as a replacement for conventional ties in reinforced concrete columns in pure compression. To achieve this objective, eight one-third-scale columns (1000 mm height, 200 × 200 mm cross-section) were tested under concentric axial loading inside a Universal Testing Machine. Four of the specimens contained WWR, while the other four had conventional ties. The variables that were considered in this study include the concrete compressive strength (34.3 and 43.5 MPa) and the grid size of the WWR (25 and 50 mm). This study investigated the influence of the type of transverse reinforcement on the strength, modulus of elasticity, and ductility of the confined concrete within the core. The findings of the study showed that lateral reinforcement in the form of WWR can increase the concrete core strength by 2.7% relative to corresponding columns employing ties when f′c = 34.3 MPa was used. Conversely, the utilization of ties proved to be more effective than WWR in improving concrete core strength by an average of 28.8% when f′c = 43.5 MPa was used. Additionally, WWR reinforced columns demonstrated a marginal 2.0% rise in the modulus of elasticity and a remarkable 21.0% increase in the ductility of the confined concrete core compared with corresponding tied columns. Theoretical predictions of the axial compressive capacity of WWR reinforced columns subjected to concentric loading based on the ACI-318 code provisions underestimated the experimental results by 20%. These findings demonstrate that WWR can serve as an effective substitute for conventional ties, particularly in cases where rapid installation and reduced labor costs are prioritized.
Keywords: concrete; confinement; columns; stress–strain relationship; welded wire reinforcement concrete; confinement; columns; stress–strain relationship; welded wire reinforcement

Share and Cite

MDPI and ACS Style

Younes, A.; Tabsh, S.W. Experimental Investigation of the Confinement of Concrete Columns with Welded Wire Reinforcement. Buildings 2025, 15, 1494. https://doi.org/10.3390/buildings15091494

AMA Style

Younes A, Tabsh SW. Experimental Investigation of the Confinement of Concrete Columns with Welded Wire Reinforcement. Buildings. 2025; 15(9):1494. https://doi.org/10.3390/buildings15091494

Chicago/Turabian Style

Younes, Abdelaziz, and Sami W. Tabsh. 2025. "Experimental Investigation of the Confinement of Concrete Columns with Welded Wire Reinforcement" Buildings 15, no. 9: 1494. https://doi.org/10.3390/buildings15091494

APA Style

Younes, A., & Tabsh, S. W. (2025). Experimental Investigation of the Confinement of Concrete Columns with Welded Wire Reinforcement. Buildings, 15(9), 1494. https://doi.org/10.3390/buildings15091494

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics