Analysis and Characterization of Factors Affecting the Consistency of Tl-201 Myocardial Perfusion Single-Photon Emission Computed Tomography and Coronary Angiography Results in Patients with Suspected Coronary Artery Disease
Abstract
:1. Introduction
2. Materials and Methods
3. Results
3.1. Patients
3.2. MPS Findings
3.3. CAG Findings
3.4. Agreement and Disagreement Between MPS and CAG
4. Discussion
4.1. False Positives
4.2. False Negatives
4.3. Clinical Factors
4.4. SPECT Parameters
4.5. Limitations
5. Conclusions
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Data Availability Statement
Conflicts of Interest
Abbreviations
CAD | Coronary artery disease |
CAG | Coronary angiography |
LAD | Left anterior descending artery |
LCX | Left circumflex artery |
LM | Left main coronary artery |
MPS | Myocardial perfusion single-photon emission computed tomography |
PCI | Percutaneous coronary intervention |
QPS | Quantitative perfusion single-photon emission computed tomography |
RCA | Right coronary artery |
SPECT | Single-photon emission computed tomography |
SSS | Summed stress score |
SDS | Summed difference score |
SRS | Summed reversibility score |
TPD | Total perfusion deficit |
References
- Zaman, S.; Wasfy, J.H.; Kapil, V.; Ziaeian, B.; Parsonage, W.A.; Sriswasdi, S.; Chico, T.J.A.; Capodanno, D.; Colleran, R.; Sutton, N.R.; et al. The Lancet Commission on rethinking coronary artery disease: Moving from ischaemia to atheroma. Lancet 2025, 405, 1264–1312. [Google Scholar] [CrossRef] [PubMed]
- World Health Organization. International Statistical Classification of Diseases and Related Health Problems, 10th Revision (ICD-10); WHO: Geneva, Switzerland, 2019; Available online: https://icd.who.int/ (accessed on 12 May 2025).
- Jenkins, K.; Pompei, G.; Ganzorig, N.; Brown, S.; Beltrame, J.; Kunadian, V. Vasospastic angina: A review on diagnostic approach and management. Ther. Adv. Cardiovasc. Dis. 2024, 18, 17539447241230400. [Google Scholar] [CrossRef] [PubMed]
- Pirozzolo, G.; Martinez Pereyra, V.; Hubert, A.; Guenther, F.; Sechtem, U.; Bekeredjian, R.; Mahrholdt, H.; Ong, P.; Seitz, A. Coronary artery spasm and impaired myocardial perfusion in patients with ANOCA: Predictors from a multimodality study using stress CMR and acetylcholine testing. Int. J. Cardiol. 2021, 343, 5–11. [Google Scholar] [CrossRef]
- Chen, Y.; Pang, Z.K.; Wang, J.; Yang, R.F.; Jing, R.; Chu, H.X.; Hsu, B.; Lin, W.H.; Li, J.M. Serial Changes of (99m)Tc-Sestamibi Washout Due to Coronary Spasm Captured by Dynamic Myocardial Perfusion Imaging With Cardiac Dedicated CZT-SPECT: A Case Report. Circ. Cardiovasc. Imaging 2022, 15, e013687. [Google Scholar] [CrossRef] [PubMed]
- Abramik, J.; Mariathas, M.; Felekos, I. Coronary Microvascular Dysfunction and Vasospastic Angina—Pathophysiology, Diagnosis and Management Strategies. J. Clin. Med. 2025, 14, 1128. [Google Scholar] [CrossRef]
- Vink, C.E.M.; Borodzicz-Jazdzyk, S.; de Jong, E.A.M.; Woudstra, J.; van de Hoef, T.P.; Chamuleau, S.A.J.; Eringa, E.C.; Götte, M.J.W.; Appelman, Y. Quantitative perfusion by cardiac magnetic resonance imaging reveals compromised myocardial perfusion in patients with angina with non-obstructive coronary artery disease. Clin. Res. Cardiol. 2025, 1–11. [Google Scholar] [CrossRef]
- Favorini, S.; Perrin, T.; Hellige, G.; Arenja, N. Sudden cardiac arrest due to recurrent coronary spasm in a young woman: A case report. Eur. Heart J. Case Rep. 2023, 7, ytad253. [Google Scholar] [CrossRef]
- Oh, S.; Hyun, D.Y.; Cho, S.-G.; Hong, Y.J.; Kim, J.H.; Ahn, Y.; Jeong, M.H. Case report: A fatal case of myocardial infarction due to myocardial bridge and concomitant vasospasm: The role of stress gated SPECT. Front. Cardiovasc. Med. 2023, 10, 1188095. [Google Scholar] [CrossRef]
- Ker, W.D.S.; Neves, D.G.; Damas, A.; Mesquita, C.T.; Nacif, M.S. Myocardial Bridge and Angiotomography of the Coronary Arteries: Perfusion under Pharmacological Stress. Arq. Bras. Cardiol. 2017, 108, 572–575. [Google Scholar] [CrossRef]
- Sternheim, D.; Power, D.A.; Samtani, R.; Kini, A.; Fuster, V.; Sharma, S. Myocardial Bridging: Diagnosis, Functional Assessment, and Management: JACC State-of-the-Art Review. J. Am. Coll. Cardiol. 2021, 78, 2196–2212. [Google Scholar] [CrossRef]
- Zamfir, A.-S.; Stătescu, C.; Sascău, R.A.; Tinică, G.; Zamfir, C.L.; Cernomaz, T.-A.; Chistol, R.O.; Boișteanu, D.; Sava, A. Casting Light on The Hidden Prevalence: A Novel Perspective on Hypoplastic Coronary Artery Disease. J. Clin. Med. 2024, 13, 2555. [Google Scholar] [CrossRef] [PubMed]
- Guo, A.; Bakhshi, H.; O’Hara, J.; Genovese, L.; Fein, A.; Maghsoudi, A.; Sandesara, C. Hypoplastic Coronary Artery Disease Presenting with Ventricular Fibrillation Cardiac Arrest. Eur. J. Case Rep. Intern. Med. 2021, 8, 002736. [Google Scholar] [CrossRef] [PubMed]
- De Giorgio, F.; Abbate, A.; Stigliano, E.; Capelli, A.; Arena, V. Hypoplastic coronary artery disease causing sudden death. Report of two cases and review of the literature. Cardiovasc. Pathol. 2010, 19, e107–e111. [Google Scholar] [CrossRef]
- Villa, A.D.; Sammut, E.; Nair, A.; Rajani, R.; Bonamini, R.; Chiribiri, A. Coronary artery anomalies overview: The normal and the abnormal. World J. Radiol. 2016, 8, 537–555. [Google Scholar] [CrossRef]
- Johnson, S.G. Motion Artifacts in SPECT Myocardial Perfusion Imaging. J. Nucl. Med. Technol. 2025, 53, 138–139. [Google Scholar] [CrossRef]
- Malek, H.; Yaghoobi, N.; Hedayati, R. Artifacts in Quantitative analysis of myocardial perfusion SPECT, using Cedars-Sinai QPS Software. J. Nucl. Cardiol. 2017, 24, 534–542. [Google Scholar] [CrossRef]
- Ramos, S.M.O.; Glavam, A.P.; de Brito, A.S.X.; Kubo, T.T.A.; Tukamoto, G.; Sampaio, D.; de Sá, L.V. Prone Myocardial Perfusion Imaging and Breast Attenuation: A Phantom Study. Curr. Med. Imaging Rev. 2020, 16, 70–79. [Google Scholar] [CrossRef] [PubMed]
- Strok, A.; Salobir, B.G.; Stalc, M.; Zaletel, K. Subdiaphragmatic activity-related artifacts in myocardial perfusion scintigraphy. Radiol. Oncol. 2024, 58, 313–319. [Google Scholar] [CrossRef]
- Tawakol, A.E.; Tantawy, H.M.; Elashmawy, R.E.; Abdelhafez, Y.G.; Elsayed, Y.M. Added Value of CT Attenuation Correction and Prone Positioning in Improving Breast and Subdiaphragmatic Attenuation in Myocardial Perfusion Imaging. J. Nucl. Med. Technol. 2021, 49, 23–29. [Google Scholar] [CrossRef]
- von Felten, E.; Benetos, G.; Patriki, D.; Benz, D.C.; Rampidis, G.P.; Giannopoulos, A.A.; Bakula, A.; Gräni, C.; Pazhenkottil, A.P.; Gebhard, C.; et al. Myocardial creep-induced misalignment artifacts in PET/MR myocardial perfusion imaging. Eur. J. Nucl. Med. Mol. Imaging 2021, 48, 406–413. [Google Scholar] [CrossRef]
- Maaniitty, T.; Stenstrom, I.; Saraste, A.; Knuuti, J. Extensive and balanced reduction of myocardial blood flow in patients with suspected obstructive coronary artery disease: 15O-water PET study. Int. J. Cardiol. 2021, 338, 1–7. [Google Scholar] [CrossRef] [PubMed]
- Mann, A.; Williams, J. Considerations for Stress Testing Performed in Conjunction with Myocardial Perfusion Imaging. J. Nucl. Med. Technol. 2020, 48, 114–121. [Google Scholar] [CrossRef] [PubMed]
- Hajar, R. Risk Factors for Coronary Artery Disease: Historical Perspectives. Heart Views 2017, 18, 109–114. [Google Scholar] [CrossRef] [PubMed]
- Sarnak, M.J.; Amann, K.; Bangalore, S.; Cavalcante, J.L.; Charytan, D.M.; Craig, J.C.; Gill, J.S.; Hlatky, M.A.; Jardine, A.G.; Landmesser, U.; et al. Chronic Kidney Disease and Coronary Artery Disease: JACC State-of-the-Art Review. J. Am. Coll. Cardiol. 2019, 74, 1823–1838. [Google Scholar] [CrossRef]
- Nakanishi, R.; Gransar, H.; Slomka, P.; Arsanjani, R.; Shalev, A.; Otaki, Y.; Friedman, J.D.; Hayes, S.W.; Thomson, L.E.; Fish, M.; et al. Predictors of high-risk coronary artery disease in subjects with normal SPECT myocardial perfusion imaging. J. Nucl. Cardiol. 2016, 23, 530–541. [Google Scholar] [CrossRef]
- Berman, D.S.; Abidov, A.; Kang, X.; Hayes, S.W.; Friedman, J.D.; Sciammarella, M.G.; Cohen, I.; Gerlach, J.; Waechter, P.B.; Germano, G.; et al. Prognostic validation of a 17-segment score derived from a 20-segment score for myocardial perfusion SPECT interpretation. J. Nucl. Cardiol. 2004, 11, 414–423. [Google Scholar] [CrossRef]
- Hachamovitch, R.; Berman, D.S.; Kiat, H.; Cohen, I.; Friedman, J.D.; Shaw, L.J. Value of Stress Myocardial Perfusion Single Photon Emission Computed Tomography in Patients With Normal Resting Electrocardiograms. Circulation 2002, 105, 823–829. [Google Scholar] [CrossRef]
- DePuey, E.G. Sources of variability of gated myocardial perfusion SPECT quantitative parameters. J. Nucl. Cardiol. 2016, 23, 818–823. [Google Scholar] [CrossRef]
Parameters | Number (n = 739) | Percentage (%) |
---|---|---|
Age | 66.4 ± 12.2 | |
Gender | ||
Male | 540 | 73.1 |
Female | 199 | 26.9 |
Body height | 163.0 ± 9.1 | |
Body weight | 70.1 ± 13.3 | |
Body mass index | 26.6 ± 9.1 | |
Smoking | 366 | 49.5 |
Alcohol consumption | 243 | 32.9 |
Hypertension | 582 | 78.8 |
Diabetes | 339 | 45.9 |
Dyslipidemia | 430 | 58.2 |
Hemodialysis | 114 | 15.4 |
Previous percutaneous coronary intervention 1 | 367 | 49.7 |
Visual Interpretation | |||
---|---|---|---|
Abnormal (n = 635) | Normal (n = 104) | p-Value | |
Increased lung uptake | 476 (75.0%) | 65 (62.5%) | 0.008 |
Left ventricular dilatation | 387 (60.9%) | 21 (20.2%) | <0.001 |
Stress extent | 15.3 ± 14.7 | 1.9 ± 4.2 | <0.001 |
Redistributed extent | 8.8 ± 11.8 | 2.3 ± 4.1 | <0.001 |
Stress total perfusion deficit | 12.4 ± 11.5 | 2.1 ± 3.3 | <0.001 |
Redistributed total perfusion deficit | 7.5 ± 9.4 | 2.3 ± 3.2 | <0.001 |
Summed stress score | 9.2 ± 8.4 | 1.4 ± 2.8 | <0.001 |
Summed reversibility score | 4.6 ± 6.4 | 0.6 ± 2.1 | <0.001 |
Summed difference score | 4.3 ± 4.8 | 0.8 ± 1.1 | <0.001 |
Abnormal MPS (n = 583) | Normal MPS (n = 79) | Total (n = 662) | |
---|---|---|---|
Single vessel disease | |||
LAD | 112 (19.2%) | 25 (31.6%) | 137 (20.7%) |
LCX | 31 (5.3%) | 10 (12.7%) | 41 (6.2%) |
RCA | 43 (7.4%) | 6 (7.6%) | 49 (7.4%) |
Double vessel disease | |||
LAD + LCX | 67 (11.5%) | 14 (17.7%) | 81 (12.2%) |
LAD + RCA | 66 (11.3%) | 12 (15.2%) | 78 (11.8%) |
LCX + RCA | 27 (4.6%) | 3 (3.8%) | 30 (4.5%) |
Three-vessel disease | 204 (35.0%) | 7 (8.9%) | 211 (31.9%) |
LM only | 33 (5.7%) | 2 (2.5%) | 35 (5.3%) |
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2025 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
Tsai, F.-R.; Chan, H.-P.; Yin, C.-H.; Chen, J.-S.; Chen, Y.-S.; Shen, D.H.-Y. Analysis and Characterization of Factors Affecting the Consistency of Tl-201 Myocardial Perfusion Single-Photon Emission Computed Tomography and Coronary Angiography Results in Patients with Suspected Coronary Artery Disease. Diagnostics 2025, 15, 1551. https://doi.org/10.3390/diagnostics15121551
Tsai F-R, Chan H-P, Yin C-H, Chen J-S, Chen Y-S, Shen DH-Y. Analysis and Characterization of Factors Affecting the Consistency of Tl-201 Myocardial Perfusion Single-Photon Emission Computed Tomography and Coronary Angiography Results in Patients with Suspected Coronary Artery Disease. Diagnostics. 2025; 15(12):1551. https://doi.org/10.3390/diagnostics15121551
Chicago/Turabian StyleTsai, Fu-Ren, Hung-Pin Chan, Chun-Hao Yin, Jin-Shuen Chen, Yao-Shen Chen, and Daniel Hueng-Yuan Shen. 2025. "Analysis and Characterization of Factors Affecting the Consistency of Tl-201 Myocardial Perfusion Single-Photon Emission Computed Tomography and Coronary Angiography Results in Patients with Suspected Coronary Artery Disease" Diagnostics 15, no. 12: 1551. https://doi.org/10.3390/diagnostics15121551
APA StyleTsai, F.-R., Chan, H.-P., Yin, C.-H., Chen, J.-S., Chen, Y.-S., & Shen, D. H.-Y. (2025). Analysis and Characterization of Factors Affecting the Consistency of Tl-201 Myocardial Perfusion Single-Photon Emission Computed Tomography and Coronary Angiography Results in Patients with Suspected Coronary Artery Disease. Diagnostics, 15(12), 1551. https://doi.org/10.3390/diagnostics15121551