Next Article in Journal
Polyamidoamines Derived from Natural α-Amino Acids as Effective Flame Retardants for Cotton
Next Article in Special Issue
Multiscale Modeling and Simulation of Polymer Blends in Injection Molding: A Review
Previous Article in Journal
Stimuli-Responsive Zinc (II) Coordination Polymers: A Novel Platform for Supramolecular Chromic Smart Tools
Previous Article in Special Issue
Radiation Shielding of Fiber Reinforced Polymer Composites Incorporating Lead Nanoparticles—An Empirical Approach
 
 
Article
Peer-Review Record

Non-Isothermal Crystallization Kinetics of Poly(ethylene glycol) and Poly(ethylene glycol)-B-Poly(ε-caprolactone) by Flash DSC Analysis

Polymers 2021, 13(21), 3713; https://doi.org/10.3390/polym13213713
by Xiaodong Li *, Meishuai Zou *, Lisha Lei and Longhao Xi
Reviewer 1: Anonymous
Reviewer 2: Anonymous
Polymers 2021, 13(21), 3713; https://doi.org/10.3390/polym13213713
Submission received: 29 September 2021 / Revised: 15 October 2021 / Accepted: 21 October 2021 / Published: 27 October 2021
(This article belongs to the Special Issue Advanced Polymer Simulation and Processing)

Round 1

Reviewer 1 Report

This is an interesting study, however, for people not dealing with this specialised DSC technique, the introduction is missing important information. How does the technique work, what are its advantages? For regular DSC experiments, the heating usually proceeds at 10deg/s. You are using 2000K/s? How does this work? Can you describe the technique a little better in the introduction? 

What is the size/weight of the sample measured by DSC?

p.1 line 32 Omit this part of the sentence, makes no sense:  "which has a great effect on the study of crystallization kinetics".

 The text in 2.2 is not about sample preparation, change the title, sample preparation text should be added too though.

In the conclusions, explain a little better why you combined the three models. What they tell you separately and together. How can you use the obtained knowledge?

 

Author Response

Please see the attachment

Author Response File: Author Response.docx

Reviewer 2 Report

  1. The Introduction of the paper is very general. The authors only outline the characteristics of their method of measurement using the FDSC technique and how this compares with the conventional DSC. They also only mention about the advantages of using PEG and PEG-PCL in applications and why their knowing of crystallization properties is important. The authors perhaps should mention also about a few previous works from the literature in which specifically the crystallization behavior of PEG and PEG-PCL was studied.
  2. The time units are missing from the horizontal (time) axis of the graph in Figure 1.
  3. The authors use for the temperature units throughout the paper both Kelvin and Celcius units. I am wondering if for the sake of uniformity in the units of the mentioned physical quantities they should only use one of the two units throughout the paper (?).
  4. It is not clear whether the results that the authors present in Figures 2 and 3 and list on Table 1 correspond to measurements using the conventional DSC technique or the FDSC? - the authors mention in lines 127-129 that in order to explain their observations they used FDSC thus it is not clear whether the presented results are from DSC or FDSC measurements (?).

Author Response

Please see the attachment

Author Response File: Author Response.docx