Next Article in Journal
Physics-Informed Machine Learning for Intelligent Gas Turbine Digital Twins: A Review
Previous Article in Journal
Energy and Environmental Impacts of Replacing Gasoline with LPG Under Real Driving Conditions
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
This is an early access version, the complete PDF, HTML, and XML versions will be available soon.
Article

Stability Assessment and Current Controller Design for Multiple Grid-Connected Inverters Under LC Grid Impedance and Grid Distortions

by
Sung-Dong Kim
,
Min Kang
,
Seung-Yong Yeo
,
Luong Duc-Tai Cu
and
Kyeong-Hwa Kim
*
Department of Electrical and Information Engineering, Research Center for Electrical and Information Technology, Seoul National University of Science and Technology, 232 Gongneung-ro, Nowon-gu, Seoul 01811, Republic of Korea
*
Author to whom correspondence should be addressed.
These authors are co-first author.
Energies 2025, 18(20), 5524; https://doi.org/10.3390/en18205524
Submission received: 3 September 2025 / Revised: 17 October 2025 / Accepted: 17 October 2025 / Published: 20 October 2025

Abstract

The increasing global energy demand is driving the deployment of renewable energy in the electrical power infrastructure, which emphasizes the critical importance of grid-connected inverters (GCIs). As the power injected into the utility grid increases, GCIs commonly operate in parallel. However, interactions between multiple GCIs and the presence of LC grid impedance pose significant challenges to the stable operation of GCIs. Existing control strategies to deal with multiple GCIs often neglect the capacitive component of grid impedance, which results in instability and deteriorated power quality in a complex grid condition. To overcome these problems, this study proposes a current control scheme and stability assessment of multiple GCIs. To effectively mitigate high-frequency resonance, the proposed method is achieved by an incomplete state feedback control which eliminates the feedback control terms for unmeasurable states. Furthermore, resonant and integral control terms are incorporated to reduce steady-state error as well as to improve harmonic compensation induced by the PCC voltages. A full-state observer is employed to reduce sensing requirements and simplify system complexity. Multiple-GCI behavior is comprehensively analyzed under complex grid environments. A comprehensive stability assessment is also conducted to evaluate the interactions of multiple GCI systems with LC grid impedance. The effectiveness of the designed controller in enhancing power quality and guaranteeing system stability is validated by theoretical analysis, PSIM simulations, and experimental tests on a DSP-controlled 2 kW prototype system.
Keywords: grid distortion; incomplete state feedback control; LC grid impedance; multiple grid-connected inverters; resonance suppression; stability assessment grid distortion; incomplete state feedback control; LC grid impedance; multiple grid-connected inverters; resonance suppression; stability assessment

Share and Cite

MDPI and ACS Style

Kim, S.-D.; Kang, M.; Yeo, S.-Y.; Cu, L.D.-T.; Kim, K.-H. Stability Assessment and Current Controller Design for Multiple Grid-Connected Inverters Under LC Grid Impedance and Grid Distortions. Energies 2025, 18, 5524. https://doi.org/10.3390/en18205524

AMA Style

Kim S-D, Kang M, Yeo S-Y, Cu LD-T, Kim K-H. Stability Assessment and Current Controller Design for Multiple Grid-Connected Inverters Under LC Grid Impedance and Grid Distortions. Energies. 2025; 18(20):5524. https://doi.org/10.3390/en18205524

Chicago/Turabian Style

Kim, Sung-Dong, Min Kang, Seung-Yong Yeo, Luong Duc-Tai Cu, and Kyeong-Hwa Kim. 2025. "Stability Assessment and Current Controller Design for Multiple Grid-Connected Inverters Under LC Grid Impedance and Grid Distortions" Energies 18, no. 20: 5524. https://doi.org/10.3390/en18205524

APA Style

Kim, S.-D., Kang, M., Yeo, S.-Y., Cu, L. D.-T., & Kim, K.-H. (2025). Stability Assessment and Current Controller Design for Multiple Grid-Connected Inverters Under LC Grid Impedance and Grid Distortions. Energies, 18(20), 5524. https://doi.org/10.3390/en18205524

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.