On-Chip Immunoassay for Determination of Urinary Albumin
Abstract
:1. Introduction
2. Results and Discussion
2.1. Reaction Time
2.2. Effect of Carrier-Buffer pH
2.3. Effect of Temperature
2.4. Calibration Curve and Limit of Detection
2.5. Interference Effects
2.6. Precision and Carry-Over Affect
2.7. Analysis of Urine Samples
3. Experimental Section
3.1. Chemicals, Reagents and Samples
3.2. Apparatus and Instrumentation
3.3. PDMS Microchip Fabrication and Design
3.4. Microfluidic System Set-Up
3.5. Assay Procedure
3.6. Immunoturbidimetric Method
4. Conclusions
Acknowledgments
References and Notes
- McIntyre, N.J.; Taal, M.W. How to measure proteinuria&? Curr. Opin. Nephrol. Hypertens. 2008, 17, 600–603. [Google Scholar]
- Gross, J.L.; de Azevedo, M.J.; Silveiro, S.P.; Canani, L.H.; Caramori, M.L.; Zelmanovitz, T. Diabetic nephropathy: diagnosis, prevention, and treatment. Diabetes Care 2005, 28, 164–176. [Google Scholar]
- Sacks, D.B.; Bruns, D.E.; Goldstein, D.E.; Maclaren, N.K.; McDonald, J.M.; Parrott, M. Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus. Diabetes Care 2002, 25, 750–786. [Google Scholar]
- Woo, J.; Floyd, M.; Cannon, D.C.; Kahan, B. Radioimmunoassay for urinary albumin. Clin. Chem. 1978, 24, 1464–1467. [Google Scholar]
- Thakkar, H.; Newman, D.J.; Holownia, P.; Davey, C.L.; Wang, C.C.; Lloyd, J.; Craig, A.R.; Price, C.P. Development and validation of a particle-enhanced turbidimetric inhibition assay for urine albumin on the Dade aca analyzer. Clin. Chem. 1997, 43, 109–113. [Google Scholar]
- Stamp, R.J. Measurement of albumin in urine by end-point immunonephelometry. Ann. Clin. Biochem. 1988, 25 Pt 4, 442–443. [Google Scholar]
- Wu, T.L.; Chang, P.Y.; Li, C.C.; Tsao, K.C.; Sun, C.F.; Wu, J.T. Microplate ELISA for urine microalbumin: Reference values and results in patients with type 2 diabetes and cardiovascular disease. Ann. Clin. Lab. Sci. 2005, 35, 149–154. [Google Scholar]
- Pegoraro, A.A.; Peracha, W.; Hasnain, M.; Ranginwala, N.; Shaykh, M.; Singh, A.K.; Arruda, J.A.L.; Dunea, G. Evaluation of a new fluorescent dye method to measure urinary albumin in lieu of urinary total protein. Am. J. Kidney Dis. 2000, 35, 739–744. [Google Scholar]
- Connolly, P. Clinical diagnostics opportunities for biosensors and bioelectronics. Biosens. Bioelectron. 1995, 10, 1–6. [Google Scholar]
- Fang, Q.; Sun, M.; Huang, Y.Z. Capillary-based microfluidic analysis systems. Anal. Bioanal. Chem. 2009, 393, 63–66. [Google Scholar]
- Degre, G.; Brunet, E.; Dodge, A.; Tabeling, P. Improving agglutination tests by working in microfluidic channels. Lab Chip 2005, 5, 691–694. [Google Scholar]
- Henares, T.G.; Mizutani, F.; Hisamoto, H. Current development in microfluidic immunosensing chip. Anal. Chim. Acta 2008, 611, 17–30. [Google Scholar]
- Lucas, L.J.; Han, J.-H.; Chesler, J.; Yoon, J.-Y. Latex immunoagglutination assay for a vasculitis marker in a microfluidic device using static light scattering detection. Biosens. Bioelectron. 2007, 22, 2216–2222. [Google Scholar]
- Panini, N.V.; Messina, G.A.; Salinas, E.; Fernández, H.; Raba, J. Integrated microfluidic systems with an immunosensor modified with carbon nanotubes for detection of prostate specific antigen (PSA) in human serum samples. Biosens. Bioelectron. 2008, 23, 1145–1151. [Google Scholar]
- Heyries, K.A.; Loughran, M.G.; Hoffmann, D.; Homsy, A.; Blum, L.J.; Marquette, C.A. Microfluidic biochip for chemiluminescent detection of allergen-specific antibodies. Biosens. Bioelectron. 2008, 23, 1812–1818. [Google Scholar]
- Viskari, P.J.; Landers, J.P. Unconventional detection methods for microfluidic devices. Electrophoresis 2006, 27, 1797–1810. [Google Scholar]
- Kong, J.; Jiang, L.; Su, X.; Qin, J.; Du, Y.; Lin, B. Integrated microfluidic immunoassay for the rapid determination of clenbuterol. Lab Chip 2009, 9, 1541–1547. [Google Scholar]
- Luo, C.; Fu, Q.; Li, H.; Xu, L.; Sun, M.; Ouyang, Q.; Chen, Y.; Ji, H. PDMS microfludic device for optical detection of protein immunoassay using gold nanoparticles. Lab Chip 2005, 5, 726–729. [Google Scholar]
- Sia, S.K.; Whitesides, G.M. Microfluidic devices fabricated in poly(dimethylsiloxane) for biological studies. Electrophoresis 2003, 24, 3563–3576. [Google Scholar]
- Zhao, D.S.; Roy, B.; McCormick, M.T.; Kuhr, W.G.; Brazill, S.A. Rapid fabrication of a poly(dimethylsiloxane) microfluidic capillary gel electrophoresis system utilizing high precision machining. Lab Chip 2003, 3, 93–99. [Google Scholar]
- Han, J.H.; Kim, K.S.; Yoon, J.Y. The enhanced diffusional mixing for latex immunoagglutination assay in a microfluidic device. Anal. Chim. Acta 2007, 584, 252–259. [Google Scholar]
- Bernard, A.M.; Vyskocil, A.; Lauwerys, R.R. Determination of beta 2-microglobulin in human urine and serum by latex immunoassay. Clin. Chem. 1981, 27, 832–837. [Google Scholar]
- BIOTOL; Currell, B.C.; Dam-Mieras, R.C.E. Antigen-Antibody Reaction, Technological Applications of Immunochemicals; Butterworth-Heinemann Ltd: Oxford, UK, 1994. [Google Scholar]
- Yoon, J.Y.; You, D.J. Backscattering particle immunoassays in wire-guide droplet manipulations. J. Biol. Eng. 2008, 2, 15. [Google Scholar]
- Contois, J.H.; Hartigan, C.; Rao, L.V.; Snyder, L.M.; Thompson, M.J. Analytical validation of an HPLC assay for urinary albumin. Clin. Chim. Acta 2006, 367, 150–155. [Google Scholar]
- Comper, W.D.; Jerums, G.; Osicka, T.M. Differences in urinary albumin detected by four immunoassays and high-performance liquid chromatography. Clin. Biochem. 2004, 37, 105–111. [Google Scholar]
- Haeckel, R. Proposals for the description and masurement of carry-over effects in clinical chemistry. Pure Appl. Chem. 1991, 63, 301–306. [Google Scholar]
- Bland, J.M.; Altman, D.G. Measuring agreement in method comparison studies. Stat. Methods Med. Res. 1999, 8, 135–160. [Google Scholar]
- Bablok, P.H. A new biometrical procedure for testing the equality of measurements from two different analytical methods. Application of linear regression procedures for method comparison studies in clinical chemistry, Part I. J. Clin. Chem. Clin. Biochem. 1983, 21, 709–720. [Google Scholar]
- Songjaroen, T.; Maturos, T.; Sappat, A.; Tuantranont, A.; Laiwattanapaisal, W. Portable microfluidic system for determination of urinary creatinine. Anal. Chim. Acta 2009, 647, 78–83. [Google Scholar]
- Han, J.-H.; Heinze, B.C.; Yoon, J.-Y. Single cell level detection of Escherichia coli in microfluidic device. Biosens. Bioelectron. 2008, 23, 1303–1306. [Google Scholar]
- Heinze, B.C.; Song, J.-Y.; Lee, C.-H.; Najam, A.; Yoon, J.-Y. Microfluidic immunosensor for rapid and sensitive detection of bovine viral diarrhea virus. Sens. Actuat. B-Chem. 2009, 138, 491–496. [Google Scholar]
- Molina-Bolívar, J.A.; Galisteo-González, F. Latex immunoagglutination assays. Polym. Rev. 2005, 45, 59–98. [Google Scholar]
Tested substances | Concentration (mg L–1) | %Recovery |
---|---|---|
albumin | 5.0 | 100.0 ± 3.7 |
haemoglobin | 0.2 | 110.0 ± 2.8 |
IgG | 3.0 | 111.3 ± 0.9 |
transferrin | 3.0 | 115.3 ± 2.8 |
bilirubin | 80.0 | 114.0 ± 0.9 |
NaCl | 1,500.0 | 110.7 ± 1.8 |
ascorbic acid | 200.0 | 101.3 ± 3.7 |
glucose | 1,250.0 | 100.0 ± 0.0 |
© 2009 by the authors; licensee Molecular Diversity Preservation International, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
Share and Cite
Laiwattanapaisal, W.; Songjaroen, T.; Maturos, T.; Lomas, T.; Sappat, A.; Tuantranont, A. On-Chip Immunoassay for Determination of Urinary Albumin. Sensors 2009, 9, 10066-10079. https://doi.org/10.3390/s91210066
Laiwattanapaisal W, Songjaroen T, Maturos T, Lomas T, Sappat A, Tuantranont A. On-Chip Immunoassay for Determination of Urinary Albumin. Sensors. 2009; 9(12):10066-10079. https://doi.org/10.3390/s91210066
Chicago/Turabian StyleLaiwattanapaisal, Wanida, Temsiri Songjaroen, Thitima Maturos, Tanom Lomas, Assawapong Sappat, and Adisorn Tuantranont. 2009. "On-Chip Immunoassay for Determination of Urinary Albumin" Sensors 9, no. 12: 10066-10079. https://doi.org/10.3390/s91210066
APA StyleLaiwattanapaisal, W., Songjaroen, T., Maturos, T., Lomas, T., Sappat, A., & Tuantranont, A. (2009). On-Chip Immunoassay for Determination of Urinary Albumin. Sensors, 9(12), 10066-10079. https://doi.org/10.3390/s91210066