Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (126)

Search Parameters:
Keywords = seismic vibration control

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
21 pages, 3511 KB  
Article
Seismic Performance Assessment of 170 kV Line Trap Systems Through Shake Table Testing and Finite Element Analysis
by Fezayil Sunca
Appl. Sci. 2025, 15(19), 10734; https://doi.org/10.3390/app151910734 - 5 Oct 2025
Abstract
Line traps are critical components of power line carrier systems, enabling remote control signaling, voice communication, and inter-substation control within electrical transmission and distribution networks. Despite their importance, limited research has addressed their seismic performance, particularly under near-fault and far-fault ground motions. This [...] Read more.
Line traps are critical components of power line carrier systems, enabling remote control signaling, voice communication, and inter-substation control within electrical transmission and distribution networks. Despite their importance, limited research has addressed their seismic performance, particularly under near-fault and far-fault ground motions. This study addresses this gap by experimentally and numerically evaluating a full-scale 170 kV line trap. Ambient Vibration Tests (AVTs), using Enhanced Frequency Domain Decomposition (EFDD), and shake table testing established its modal and seismic response characteristics. A finite element (FE) model was then developed and calibrated using the experimental results. Dynamic analyses were conducted to evaluate the structural response under both near-fault and far-fault ground motions. Experimental findings revealed that the seismic response of the line trap increased with height, with the upper segment experiencing over four times the base acceleration. Numerical analyses further demonstrated that near-fault ground motions induced significantly higher displacement and acceleration responses than far-fault records. These findings collectively constitute a detailed investigation into the seismic performance of a full-scale line trap, emphasizing the pivotal role of ground motion characteristics in the structural evaluation of substation apparatus. Full article
Show Figures

Figure 1

27 pages, 5759 KB  
Article
A Comprehensive Experimental Study on the Dynamic Identification of Historical Three-Arch Masonry Bridges Using Operational Modal Analysis
by Cristiano Giuseppe Coviello and Maria Francesca Sabbà
Appl. Sci. 2025, 15(19), 10577; https://doi.org/10.3390/app151910577 - 30 Sep 2025
Abstract
This article presents an extensive experimental investigation of the dynamic characteristics of three-arch historical masonry bridges, using Operational Modal Analysis (OMA). The research thoroughly characterizes the dynamic behavior of four representative masonry bridges from the Apulia Region in Southern Italy through detailed experimental [...] Read more.
This article presents an extensive experimental investigation of the dynamic characteristics of three-arch historical masonry bridges, using Operational Modal Analysis (OMA). The research thoroughly characterizes the dynamic behavior of four representative masonry bridges from the Apulia Region in Southern Italy through detailed experimental campaigns. These campaigns employed calibrated and optimally implemented accelerometric monitoring systems to acquire high-quality dynamic data under controlled excitation and environmental conditions. The selected bridges include the Santa Teresa Bridge in Bitonto, the Roman Bridge in Bovino, the Roman Bridge in Ascoli Satriano and a moderner road bridge on the Provincial Road SP123 in Troia; they span almost two millennia of construction history. The experimental framework incorporated several non-invasive excitation methods, including controlled vehicle passes, instrumented hammer impacts and ambient vibration tests, strategically chosen for optimal signal quality and heritage preservation. This investigation demonstrates the feasibility of capturing the dynamic behavior of these complex and specific historic structures through customized sensor configurations and various excitation methods. The resulting natural frequencies and mode shapes are accurate, robust, and reliable considering the extended data set used, and have allowed a rigorous seismic assessment. Eventually, this comprehensive data set establishes a fundamental basis for understanding and predicting the seismic response of several three-span masonry bridges to accurately identify their long-term resilience and effective conservation planning of these valuable and vulnerable heritage structures. In conclusion, the data comparison enabled the formulation of a predictive equation for the identification of the first natural frequency of bridges from geometric characteristics. Full article
Show Figures

Figure 1

21 pages, 20900 KB  
Article
Balancing Accuracy and Efficiency in Wire-Rope Isolator Modeling: A Simplified Beam-Element Framework
by Claudia Marin-Artieda
Vibration 2025, 8(3), 55; https://doi.org/10.3390/vibration8030055 - 22 Sep 2025
Viewed by 170
Abstract
Wire-rope isolators (WRIs) are widely used in vibration and seismic protection due to their multidirectional flexibility and amplitude-dependent hysteretic damping. However, their complex nonlinear behavior, especially under inclined and combined-mode loading, poses challenges for predictive modeling. This study presents a simplified finite-element modeling [...] Read more.
Wire-rope isolators (WRIs) are widely used in vibration and seismic protection due to their multidirectional flexibility and amplitude-dependent hysteretic damping. However, their complex nonlinear behavior, especially under inclined and combined-mode loading, poses challenges for predictive modeling. This study presents a simplified finite-element modeling framework using constant-property Timoshenko beam elements with tuned Rayleigh damping to simulate WRI behavior across various configurations. Benchmark validation against analytical ring deformation confirmed the model’s ability to capture geometric nonlinearities. The framework was extended to five WRI types, with effective cross-sectional properties calibrated against vendor-supplied quasi-static data. Dynamic simulations under sinusoidal excitation demonstrated strong agreement with experimental force-displacement loops in pure modes and showed moderate accuracy (within 29%) in inclined configurations. System-level validation using a rocking-control platform with four inclined WRIs showed that the model reliably predicts global stiffness and energy dissipation under base accelerations. While the model does not capture localized nonlinearities such as pinched hysteresis due to interstrand friction, it offers a computationally efficient tool for engineering design. The proposed method enables rapid evaluation of WRI performance in complex scenarios, supporting broader integration into performance-based seismic mitigation strategies. Full article
(This article belongs to the Special Issue Nonlinear Vibration of Mechanical Systems)
Show Figures

Figure 1

16 pages, 1463 KB  
Article
Adaptive Harmony Search-Based Optimization of Tuned Mass Damper Inerters Under Near-Fault Earthquake Records
by Yaren Aydın, Gebrail Bekdaş, Sinan Melih Nigdeli, Sanghun Kim and Zong Woo Geem
GeoHazards 2025, 6(3), 56; https://doi.org/10.3390/geohazards6030056 - 11 Sep 2025
Viewed by 314
Abstract
Dynamic effects such as wind, traffic, and earthquakes can cause loss of life and property. Since tall buildings are more sensitive to these vibrations, vibration control is an important issue in civil engineering. In this study, the Adaptive Harmony Search (AHS) was used [...] Read more.
Dynamic effects such as wind, traffic, and earthquakes can cause loss of life and property. Since tall buildings are more sensitive to these vibrations, vibration control is an important issue in civil engineering. In this study, the Adaptive Harmony Search (AHS) was used to determine the optimum TMDI parameters. AHS shares similar steps with the classic Harmony Search (HS), which simulates the process of musicians creating new harmonies. However, unlike HS, it uses harmony memory consideration rate (HMCR) and pitch adjustment rate (PAR) values that are updated at each search step, rather than fixed HMCR and PAR values. The aim of the optimization is to minimize the maximum displacement of the upper floor in a 10-story shear building against different earthquake records. To evaluate the performance of the TMDI system, displacement and total acceleration under seismic loading were analyzed. As a result, the TMDI reduced displacement by 35% and 13.33% for non-pulse and pulse, respectively, for near-fault earthquake records. These reductions indicate that the structure’s resistance to dynamic loads can be enhanced using control systems. Full article
Show Figures

Figure 1

23 pages, 3338 KB  
Article
Hierarchical Fuzzy-Adaptive Position Control of an Active Mass Damper for Enhanced Structural Vibration Suppression
by Omer Saleem, Massimo Leonardo Filograno, Soltan Alharbi and Jamshed Iqbal
Mathematics 2025, 13(17), 2816; https://doi.org/10.3390/math13172816 - 2 Sep 2025
Viewed by 597
Abstract
This paper presents the formulation and simulation-based validation of a novel hierarchical fuzzy-adaptive Proportional–Integral–Derivative (PID) control framework for a rectilinear active mass damper, designed to enhance vibration suppression in structural applications. The proposed scheme utilizes a Linear–Quadratic Regulator (LQR)-optimized PID controller as the [...] Read more.
This paper presents the formulation and simulation-based validation of a novel hierarchical fuzzy-adaptive Proportional–Integral–Derivative (PID) control framework for a rectilinear active mass damper, designed to enhance vibration suppression in structural applications. The proposed scheme utilizes a Linear–Quadratic Regulator (LQR)-optimized PID controller as the baseline regulator. To address the limitations of this baseline PID controller under varying seismic excitations, an auxiliary fuzzy adaptation layer is integrated to adjust the state-weighting matrices of the LQR performance index dynamically. The online modification of the state weightages alters the Riccati equation’s solution, thereby updating the PID gains at each sampling instant. The fuzzy adaptive mechanism modulates the said weighting parameters as nonlinear functions of the classical displacement error and normalized acceleration. Normalized acceleration provides fast, scalable, and effective feedback for vibration mitigation in structural control using AMDs. By incorporating the system’s normalized acceleration into the adaptation scheme, the controller achieves improved self-tuning, allowing it to respond efficiently and effectively to changing conditions. The hierarchical design enables robust real-time PID gain adaptation while maintaining the controller’s asymptotic stability. The effectiveness of the proposed controller is validated through customized MATLAB/SIMULINK-based simulations. Results demonstrate that the proposed adaptive PID controller significantly outperforms the baseline PID controller in mitigating structural vibrations during seismic events, confirming its suitability for intelligent structural control applications. Full article
Show Figures

Figure 1

26 pages, 1923 KB  
Review
Review of Energy Dissipation Mechanisms in Concrete: Role of Advanced Materials, Mix Design, and Curing Conditions
by Hadi Bahmani, Hasan Mostafaei and Davood Mostofinejad
Sustainability 2025, 17(15), 6723; https://doi.org/10.3390/su17156723 - 24 Jul 2025
Cited by 3 | Viewed by 836
Abstract
Concrete structures increasingly face dynamic loading conditions, such as seismic events, vehicular traffic, and environmental vibrations, necessitating enhanced energy dissipation capabilities. The damping ratio, a critical parameter quantifying a material’s ability to dissipate vibrational energy, is typically low in conventional concrete, prompting extensive [...] Read more.
Concrete structures increasingly face dynamic loading conditions, such as seismic events, vehicular traffic, and environmental vibrations, necessitating enhanced energy dissipation capabilities. The damping ratio, a critical parameter quantifying a material’s ability to dissipate vibrational energy, is typically low in conventional concrete, prompting extensive research into strategies for improvement. This review comprehensively explores the impact of advanced concrete types—such as Engineered Cementitious Composites (ECCs), Ultra-High-Performance Concrete (UHPC), High-Performance Concrete (HPC), and polymer concrete—on enhancing the damping behavior. Additionally, key mix design innovations, including fiber reinforcement, rubber powder incorporation, and aggregate modification, are evaluated for their roles in increasing energy dissipation. External factors, particularly curing conditions, are also discussed for their influence on the damping performance. The findings consolidate experimental and theoretical insights into how material composition, mix design, and external treatments interact to optimize dynamic resilience. To guide future research, this paper identifies critical gaps including the need for multi-scale numerical simulation frameworks, standardized damping test protocols, and long-term performance evaluation under realistic service conditions. Advancing work in material innovation, optimized mix design, and controlled curing environments will be essential for developing next-generation concretes with superior vibration control, durability, and sustainability. These insights provide a strategic foundation for applications in seismic-prone and vibration-sensitive infrastructure. Full article
(This article belongs to the Special Issue Advanced Concrete- and Cement-Based Composite Materials)
Show Figures

Figure 1

23 pages, 9795 KB  
Article
Evaluation of Viscoelastic and Rotational Friction Dampers for Coupled Shear Wall System
by Zafira Nur Ezzati Mustafa, Ryo Majima and Taiki Saito
Appl. Sci. 2025, 15(15), 8185; https://doi.org/10.3390/app15158185 - 23 Jul 2025
Viewed by 519
Abstract
This research experimentally and numerically evaluates the effectiveness of viscoelastic (VE) and rotational friction (RF) dampers in enhancing the seismic performance of coupled shear wall (CSW) systems. This study consists of two phases: (1) element testing to characterize the hysteretic behavior and energy [...] Read more.
This research experimentally and numerically evaluates the effectiveness of viscoelastic (VE) and rotational friction (RF) dampers in enhancing the seismic performance of coupled shear wall (CSW) systems. This study consists of two phases: (1) element testing to characterize the hysteretic behavior and energy dissipation capacity of VE and RF dampers, and (2) shake table testing of a large-scale CSW structure equipped with these dampers under the white noise, sinusoidal and Kokuji waves. The experimental results are validated through numerical analysis using STERA 3D (version 11.5), a nonlinear finite element software, to simulate the dynamic response of the damped CSW system. Key performance indicators, including inter-story drift, base shear, and energy dissipation, are compared between experimental and numerical results, demonstrating strong correlation. The findings reveal that VE dampers effectively control high-frequency vibrations, while RF dampers provide stable energy dissipation across varying displacement amplitudes. The validated numerical model facilitates the optimization of damper configurations for performance-based seismic design. This study provides valuable insights into the selection and implementation of supplemental damping systems for CSW structures, contributing to improved seismic resilience in buildings. Full article
(This article belongs to the Special Issue Nonlinear Dynamics and Vibration)
Show Figures

Figure 1

19 pages, 4729 KB  
Article
Performance Enhancement of Seismically Protected Buildings Using Viscoelastic Tuned Inerter Damper
by Pan-Pan Gai, Jun Dai, Yang Yang, Qin-Sheng Bi, Qing-Song Guan and Gui-Yu Zhang
Actuators 2025, 14(8), 360; https://doi.org/10.3390/act14080360 - 22 Jul 2025
Viewed by 359
Abstract
In this paper, a viscoelastic (VE) tuned inerter damper (TID) that replaces conventional stiffness and damping elements with a cost-effective VE element is proposed to achieve a target-based improvement of seismically protected buildings. The semi-analytical solution of the optimal tuning frequency ratio of [...] Read more.
In this paper, a viscoelastic (VE) tuned inerter damper (TID) that replaces conventional stiffness and damping elements with a cost-effective VE element is proposed to achieve a target-based improvement of seismically protected buildings. The semi-analytical solution of the optimal tuning frequency ratio of the VE TID is presented based on a two-degree-of-freedom (2-DOF) system, accounting for inherent structural damping disturbances, and then is extended to a MDOF system via an effective mass ratio. The accuracy of the semi-analytical solution is validated by comparing the numerical solution. Finally, numerical analyses on a viscoelastically damped building and a base-isolated building with optimally designed VE TIDs under historical earthquakes are performed. The numerical results validate the target-based improvement capability of the VE TID with a modest mass ratio in avoiding large strokes or deformation of existing dampers and isolators, and further reducing the specific mode vibration. Full article
(This article belongs to the Section Control Systems)
Show Figures

Figure 1

25 pages, 4994 KB  
Article
Dynamic Slope Stability Assessment Under Blast-Induced Ground Vibrations in Open-Pit Mines: A Pseudo-Static Limit Equilibrium Approach
by Sami Ullah, Gaofeng Ren, Yongxiang Ge, Muhammad Burhan Memon, Eric Munene Kinyua and Theoneste Ndayiragije
Sustainability 2025, 17(14), 6642; https://doi.org/10.3390/su17146642 - 21 Jul 2025
Viewed by 1015
Abstract
Blasting is one of the most widely used and cost-effective techniques for rock excavation and fragmentation in open-pit mining, particularly for large-scale operations. However, repeated or poorly controlled blasting can generate excessive ground vibrations that threaten slope stability by causing structural damage, fracturing [...] Read more.
Blasting is one of the most widely used and cost-effective techniques for rock excavation and fragmentation in open-pit mining, particularly for large-scale operations. However, repeated or poorly controlled blasting can generate excessive ground vibrations that threaten slope stability by causing structural damage, fracturing of the rock mass, and potential failure. Evaluating the effects of blast-induced vibrations is essential to ensure safe and sustainable mining operations. This study investigates the impact of blasting-induced vibrations on slope stability at the Saindak Copper-Gold Open-Pit Mine in Pakistan. A comprehensive dataset was compiled, including field-monitored ground vibration measurements—specifically peak particle velocity (PPV) and key blast design parameters such as spacing (S), burden (B), stemming length (SL), maximum charge per delay (MCPD), and distance from the blast point (D). Geomechanical properties of slope-forming rock units were validated through laboratory testing. Slope stability was analyzed using pseudo-static limit equilibrium methods (LEMs) based on the Mohr–Coulomb failure criterion, employing four approaches: Fellenius, Janbu, Bishop, and Spencer. Pearson and Spearman correlation analyses quantified the influence of blasting parameters on slope behavior, and sensitivity analysis determined the cumulative distribution of slope failure and dynamic response under increasing seismic loads. FoS values were calculated for both east and west pit slopes under static and dynamic conditions. Among all methods, Spencer consistently yielded the highest FoS values. Under static conditions, FoS was 1.502 for the east slope and 1.254 for the west. Under dynamic loading, FoS declined to 1.308 and 1.102, reductions of 12.9% and 11.3%, respectively, as calculated using the Spencer method. The east slope exhibited greater stability due to its gentler angle. Correlation analysis revealed that burden had a significant negative impact (r = −0.81) on stability. Sensitivity analysis showed that stability deteriorates notably when PPV exceeds 10.9 mm/s. Although daily blasting did not critically compromise stability, the west slope showed greater vulnerability, underscoring the need for stricter control of blasting energy to mitigate vibration-induced instability and promote long-term operational sustainability. Full article
Show Figures

Graphical abstract

27 pages, 1555 KB  
Review
State-of-the-Art Review of Structural Vibration Control: Overview and Research Gaps
by Neethu B. Dharmajan and Mohammad AlHamaydeh
Appl. Sci. 2025, 15(14), 7966; https://doi.org/10.3390/app15147966 - 17 Jul 2025
Cited by 1 | Viewed by 1649
Abstract
This paper comprehensively reviews structural vibration control systems for earthquake mitigation in civil engineering structures. Structural vibration control is vital for enhancing the resilience and safety of infrastructure subjected to seismic activity. This study examines various control strategies, including passive, active, and hybrid [...] Read more.
This paper comprehensively reviews structural vibration control systems for earthquake mitigation in civil engineering structures. Structural vibration control is vital for enhancing the resilience and safety of infrastructure subjected to seismic activity. This study examines various control strategies, including passive, active, and hybrid methods, with a focus on the advantages of semi-active systems, which offer a balance of energy efficiency and adaptive capabilities. Semi-active devices, such as magnetorheological dampers, are highlighted for their ability to offer adaptive control without the high energy demands of fully active systems. The review discusses challenges like time delays, sensor placement, and model uncertainties that can impact the practical implementation of these systems. Experimental studies and real-world applications demonstrate the effectiveness of semi-active systems in reducing seismic responses. This paper emphasizes the need for further research into optimizing control algorithms and addressing practical challenges to enhance the reliability and robustness of these systems. It concludes that semi-active control systems are a promising solution for enhancing structural resilience in earthquake-prone areas, offering a practical alternative that strikes a balance between performance and energy requirements. Full article
(This article belongs to the Special Issue Vibration Monitoring and Control of the Built Environment)
Show Figures

Figure 1

26 pages, 5716 KB  
Article
Study on Vibration Control Systems for Spherical Water Tanks Under Earthquake Loads
by Jingshun Zuo, Jingchao Guan, Wei Zhao, Keisuke Minagawa and Xilu Zhao
Vibration 2025, 8(3), 41; https://doi.org/10.3390/vibration8030041 - 11 Jul 2025
Viewed by 621
Abstract
Ensuring the safety of large spherical water storage tanks in seismic environments is critical. Therefore, this study proposed a vibration control device applicable to general spherical water tanks. By utilizing the upper interior space of a spherical tank, a novel tuned mass damper [...] Read more.
Ensuring the safety of large spherical water storage tanks in seismic environments is critical. Therefore, this study proposed a vibration control device applicable to general spherical water tanks. By utilizing the upper interior space of a spherical tank, a novel tuned mass damper (TMD) system composed of a mass block and four elastic springs was proposed. To enable practical implementation, the vibration control mechanism and tuning principle of the proposed TMD were examined. Subsequently, an experimental setup, including the spherical water tank and the TMD, was developed. Subsequently, shaking experiments were conducted using two types of spherical tanks with different leg stiffness values under various seismic waves and excitation directions. Shaking tests using actual El Centro NS and Taft NW earthquake waves demonstrated vibration reduction effects of 34.87% and 43.38%, respectively. Additional shaking experiments were conducted under challenging conditions, where the natural frequency of the spherical tank was adjusted to align closely with the dominant frequency of the earthquake waves, yielding vibration reduction effects of 18.74% and 22.42%, respectively. To investigate the influence of the excitation direction on the vibration control performance, shaking tests were conducted at 15-degree intervals. These experiments confirmed that an average vibration reduction of more than 15% was achieved, thereby verifying the validity and practicality of the proposed TMD vibration control system for spherical water tanks. Full article
Show Figures

Figure 1

29 pages, 4726 KB  
Article
Adaptive Pendulum-Tuned Mass Damper Based on Adjustable-Length Cable for Skyscraper Vibration Control
by Krzysztof Twardoch, Kacper Górski, Rafał Kwiatkowski, Kamil Jaśkielewicz and Bogumił Chiliński
Sustainability 2025, 17(14), 6301; https://doi.org/10.3390/su17146301 - 9 Jul 2025
Viewed by 1155
Abstract
The dynamic control of vibrations in skyscrapers is a critical consideration in sustainable building design, particularly in response to environmental excitations such as wind impact or seismic activity. Effective vibration neutralisation plays a crucial role in providing the safety of high-rise buildings. This [...] Read more.
The dynamic control of vibrations in skyscrapers is a critical consideration in sustainable building design, particularly in response to environmental excitations such as wind impact or seismic activity. Effective vibration neutralisation plays a crucial role in providing the safety of high-rise buildings. This research introduces an innovative concept for an active vibration damper that operates based on fluid dynamic transport to adaptively alter a skyscraper’s natural frequency, thereby counteracting resonant vibrations. A distinctive feature of this system is an adjustable-length cable mechanism, allowing for the dynamic modification of the pendulum’s effective length in real time. The structure, based on cable length adjustment, enables the PTMD to precisely tune its natural frequency to variable excitation conditions, thereby improving damping during transient or resonance phenomena of the building’s dynamic behaviour. A comprehensive mathematical model based on Lagrangian mechanics outlines the governing equations for this system, capturing the interactions between pendulum motion, fluid flow, and the damping forces necessary to maintain stability. Simulation analyses examine the role of initial excitation frequency and variable damping coefficients, revealing critical insights into optimal damper performance under varied structural conditions. The findings indicate that the proposed pendulum damper effectively mitigates resonance risks, paving the way for sustainable skyscraper design through enhanced structural adaptability and resilience. This adaptive PTMD, featuring an adjustable-length cable, provides a solution for creating safe and energy-efficient skyscraper designs, aligning with sustainable architectural practices and advancing future trends in vibration management technology. The study presented in this article supports the development of modern skyscraper design, with a focus on dynamic vibration control for sustainability and structural safety. It combines advanced numerical modelling, data-driven control algorithms, and experimental validation. From a sustainability perspective, the proposed PTMD system reduces the need for oversized structural components by providing adaptive, efficient damping, thereby lowering material consumption and embedded carbon. Through dynamically retuning structural stiffness and mass, the proposed PTMD enhances resilience and energy efficiency in skyscrapers, lowers lifetime energy use associated with passive damping devices, and enhances occupant comfort. This aligns with global sustainability objectives and new-generation building standards. Full article
Show Figures

Figure 1

22 pages, 12919 KB  
Article
Vibration Control of Deepwater Offshore Platform Using Viscous Dampers Under Wind, Wave, and Earthquake
by Kaien Jiang, Huiyang Li, Guoer Lv, Lizhong Wang, Lilin Wang and Huafeng Yu
J. Mar. Sci. Eng. 2025, 13(7), 1197; https://doi.org/10.3390/jmse13071197 - 20 Jun 2025
Viewed by 658
Abstract
This study investigates the use of viscous dampers (VDs) to reduce the vibration of a deepwater offshore platform under joint wind, wave, and earthquake action. A finite element model was established based on the Opensees software (version 3.7.1), incorporating soil–structure interaction simulated by [...] Read more.
This study investigates the use of viscous dampers (VDs) to reduce the vibration of a deepwater offshore platform under joint wind, wave, and earthquake action. A finite element model was established based on the Opensees software (version 3.7.1), incorporating soil–structure interaction simulated by the nonlinear Winkler springs and simulating hydrodynamic loads via the Morison equation. Turbulent wind fields were generated using the von Kármán spectrum, and irregular wave profiles were synthesized from the JONSWAP spectrum. The 1995 Kobe earthquake record served as seismic input. The time-history dynamic response for the deepwater offshore platform was evaluated under two critical scenarios: isolated seismic excitation and the joint action of wind, wave, and seismic loading. The results demonstrate that VDs configured diagonally at each structural level effectively suppress platform vibrations under both isolated seismic and wind–wave–earthquake conditions. Under seismic excitation, the VD system reduced maximum deck acceleration, velocity, displacement, and base shear force by 9.95%, 22.33%, 14%, and 31.08%, respectively. For combined environmental loads, the configuration achieved 15.87%, 21.48%, 13.51%, and 34.31% reductions in peak deck acceleration, velocity, displacement, and base shear force, respectively. Moreover, VD parameter analysis confirms that increased damping coefficients enhance control effectiveness. Full article
(This article belongs to the Section Ocean Engineering)
Show Figures

Figure 1

15 pages, 5426 KB  
Article
Mechanical Performance Enhancement of Self-Decoupling Magnetorheological Damper Enabled by Double-Graded High-Performance Magnetorheological Fluid
by Fei Guo, Hanbo Cui, Xiaojun Huang, Chengbin Du, Zongyun Mo and Xiaoguo Lin
Appl. Sci. 2025, 15(11), 6305; https://doi.org/10.3390/app15116305 - 4 Jun 2025
Cited by 1 | Viewed by 644
Abstract
Conventional magnetorheological fluids (MRFs) exhibit a constrained shear strength that restricts their deployment in high-performance damping systems. This study introduces a dual-axis innovation strategy combining material science and device physics to fundamentally redefine MRF capabilities. We develop a hierarchical particle architecture through the [...] Read more.
Conventional magnetorheological fluids (MRFs) exhibit a constrained shear strength that restricts their deployment in high-performance damping systems. This study introduces a dual-axis innovation strategy combining material science and device physics to fundamentally redefine MRF capabilities. We develop a hierarchical particle architecture through the controlled integration of micro/nano-sized carbonyl iron particles (CIPs), enhanced by polyethylene glycol/oleic acid surface engineering to optimize magnetic chain formation and interfacial bonding. The engineered MRF demonstrates a shear yield strength of 99.6 kPa at 0.757 T, surpassing conventional single-component MRFs by a significant margin. Integrated with a self-decoupling damper that isolates magnetic flux from mechanical motion, this synergistic design achieves exceptional force modulation: damping forces scale from 281.5 kN (5 mm stroke) to 300 kN (60 mm stroke), with current-regulated adjustability factors reaching 3.34. The system exhibits substantial improvements in both maximum damping force (93.9 kN enhancement) and energy dissipation efficiency compared to standard MRF dampers. Through co-optimization of the particle architecture and magnetic circuit design, this work establishes new performance benchmarks for smart fluid technology. The achieved force capacity and dynamic response characteristics directly address critical challenges in seismic engineering and industrial vibration control, where extreme load-bearing requirements demand simultaneous high strength and tunable damping capabilities. Full article
Show Figures

Figure 1

21 pages, 5964 KB  
Article
Research on Loosening Identification of High-Strength Bolts Based on Relaxor Piezoelectric Sensor
by Ruisheng Feng, Chao Wu, Youjia Zhang, Zijian Pan and Haiming Liu
Buildings 2025, 15(11), 1867; https://doi.org/10.3390/buildings15111867 - 28 May 2025
Viewed by 419
Abstract
Bridges play a key and controlling role in transportation systems. Steel bridges are favored for their high strength, good seismic performance, and convenient construction. As important node connectors of steel bridges, high-strength bolts are extremely susceptible to damage such as corrosion and loosening. [...] Read more.
Bridges play a key and controlling role in transportation systems. Steel bridges are favored for their high strength, good seismic performance, and convenient construction. As important node connectors of steel bridges, high-strength bolts are extremely susceptible to damage such as corrosion and loosening. Therefore, accurate identification of bolt loosening is crucial. First, a new type of adhesive piezoelectric sensor is designed and prepared using PMN-PT piezoelectric single-crystal materials. The PMN-PT sensor and polyvinylidene fluoride (PVDF) sensor are subjected to steel plate fixed frequency load and swept frequency load tests to test the performance of the two sensors. Then, a steel plate component connected by high-strength bolts is designed. By applying exciter square wave load to the structure, the vibration response characteristics of the structure are analyzed to identify the loosening of the bolts. In addition, a piezoelectric smart washer sensor is designed to make up for the shortcomings of the adhesive piezoelectric sensor, and the effectiveness of the piezoelectric smart washer sensor is verified. Finally, a bolt loosening index is proposed to quantitatively evaluate the looseness of the bolt. The results show that the sensitivity of the PMN-PT sensor is 21 times that of the PVDF sensor. Compared with the peak stress change, the natural frequency change is used to identify the bolt loosening more effectively. Piezoelectric smart washer sensor and bolt loosening indicator can be used for bolt loosening identification. Full article
(This article belongs to the Special Issue Research in Structural Control and Monitoring)
Show Figures

Figure 1

Back to TopTop