Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (23)

Search Parameters:
Keywords = patient-specific 3D-printed osteotomy guides

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
19 pages, 3117 KiB  
Article
Feasibility and Accuracy of a Dual-Function AR-Guided System for PSI Positioning and Osteotomy Execution in Pelvic Tumour Surgery: A Cadaveric Study
by Tanya Fernández-Fernández, Javier Orozco-Martínez, Carla de Gregorio-Bermejo, Elena Aguilera-Jiménez, Amaia Iribar-Zabala, Lydia Mediavilla-Santos, Javier Pascau, Mónica García-Sevilla, Rubén Pérez-Mañanes and José Antonio Calvo-Haro
Bioengineering 2025, 12(8), 810; https://doi.org/10.3390/bioengineering12080810 - 28 Jul 2025
Viewed by 257
Abstract
Objectives: Pelvic tumor resections demand high surgical precision to ensure clear margins while preserving function. Although patient-specific instruments (PSIs) improve osteotomy accuracy, positioning errors remain a limitation. This study evaluates the feasibility, accuracy, and usability of a novel dual-function augmented reality (AR) [...] Read more.
Objectives: Pelvic tumor resections demand high surgical precision to ensure clear margins while preserving function. Although patient-specific instruments (PSIs) improve osteotomy accuracy, positioning errors remain a limitation. This study evaluates the feasibility, accuracy, and usability of a novel dual-function augmented reality (AR) system for intraoperative guidance in PSI positioning and osteotomy execution using a head-mounted display (HMD). The system provides dual-function support by assisting both PSI placement and osteotomy execution. Methods: Ten fresh-frozen cadaveric hemipelves underwent AR-assisted internal hemipelvectomy, using customized 3D-printed PSIs and a new in-house AR software integrated into an HMD. Angular and translational deviations between planned and executed osteotomies were measured using postoperative CT analysis. Absolute angular errors were computed from plane normals; translational deviation was assessed as maximum error at the osteotomy corner point in both sagittal (pitch) and coronal (roll) planes. A Wilcoxon signed-rank test and Bland–Altman plots were used to assess intra-workflow cumulative error. Results: The mean absolute angular deviation was 5.11 ± 1.43°, with 86.66% of osteotomies within acceptable thresholds. Maximum pitch and roll deviations were 4.53 ± 1.32 mm and 2.79 ± 0.72 mm, respectively, with 93.33% and 100% of osteotomies meeting translational accuracy criteria. Wilcoxon analysis showed significantly lower angular error when comparing final executed planes to intermediate AR-displayed planes (p < 0.05), supporting improved PSI positioning accuracy with AR guidance. Surgeons rated the system highly (mean satisfaction ≥ 4.0) for usability and clinical utility. Conclusions: This cadaveric study confirms the feasibility and precision of an HMD-based AR system for PSI-guided pelvic osteotomies. The system demonstrated strong accuracy and high surgeon acceptance, highlighting its potential for clinical adoption in complex oncologic procedures. Full article
Show Figures

Figure 1

16 pages, 2092 KiB  
Article
Augmented Reality-Assisted Placement of Surgical Guides and Osteotomy Execution for Pelvic Tumour Resections: A Pre-Clinical Feasibility Study Using 3D-Printed Models
by Tanya Fernández-Fernández, Javier Orozco-Martínez, Amaia Iribar-Zabala, Elena Aguilera Jiménez, Carla de Gregorio-Bermejo, Lydia Mediavilla-Santos, Javier Pascau, Mónica García-Sevilla, Rubén Pérez-Mañanes and Jose Antonio Calvo-Haro
Cancers 2025, 17(13), 2260; https://doi.org/10.3390/cancers17132260 - 7 Jul 2025
Viewed by 340
Abstract
Objectives: This pre-clinical feasibility study evaluates the accuracy of a novel augmented reality-based (AR-based) guidance technology using head-mounted displays (HMDs) for the placement of patient-specific instruments (PSIs)—also referred to as surgical guides—and osteotomy performance in pelvic tumour resections. The goal is to [...] Read more.
Objectives: This pre-clinical feasibility study evaluates the accuracy of a novel augmented reality-based (AR-based) guidance technology using head-mounted displays (HMDs) for the placement of patient-specific instruments (PSIs)—also referred to as surgical guides—and osteotomy performance in pelvic tumour resections. The goal is to improve PSI placement accuracy and osteotomy execution while assessing user perception and workflow efficiency. Methods: The study was conducted on ten 3D-printed pelvic phantoms derived from CT scans of cadaveric specimens. Custom PSIs were designed and printed to guide osteotomies at the supraacetabular, symphysial, and ischial regions. An AR application was developed for the HoloLens 2 HMD to display PSI location and cutting planes. The workflow included manual supraacetabular PSI placement, AR-guided placement of the other PSIs and osteotomy execution. Postoperative CT scans were analysed to measure angular and distance errors in PSI placement and osteotomies. Task times and user feedback were also recorded. Results: The mean angular deviation for PSI placement was 2.20°, with a mean distance error of 1.19 mm (95% CI: 0.86 to 1.52 mm). Osteotomies showed an overall mean angular deviation of 3.73° compared to planned cuts, all within the predefined threshold of less than 5°. AR-assisted guidance added less than two minutes per procedure. User feedback highlighted the intuitive interface and high usability, especially for visualising cutting planes. Conclusions: Integrating AR through HMDs is a feasible and accurate method for enhancing PSI placement and osteotomy performance in pelvic tumour resections. The system provides reliable guidance even in cases of PSI failure and adds minimal time to the surgical workflow while significantly improving accuracy. Further validation in cadaveric models is needed to ensure its clinical applicability. Full article
(This article belongs to the Special Issue Clinical Treatment of Osteosarcoma)
Show Figures

Figure 1

10 pages, 449 KiB  
Article
Accuracy of Lower Extremity Alignment Correction Using Patient-Specific Cutting Guides and Anatomically Contoured Plates
by Julia Matthias, S Robert Rozbruch, Austin T. Fragomen, Anil S. Ranawat and Taylor J. Reif
J. Pers. Med. 2025, 15(7), 289; https://doi.org/10.3390/jpm15070289 - 4 Jul 2025
Viewed by 339
Abstract
Background/Objectives: Limb malalignment disrupts physiological joint forces and predisposes individuals to the development of osteoarthritis. Surgical interventions such as distal femur or high tibial osteotomy aim to restore mechanical balance on weight-bearing joints, thereby reducing long-term morbidity. Accurate alignment is crucial since [...] Read more.
Background/Objectives: Limb malalignment disrupts physiological joint forces and predisposes individuals to the development of osteoarthritis. Surgical interventions such as distal femur or high tibial osteotomy aim to restore mechanical balance on weight-bearing joints, thereby reducing long-term morbidity. Accurate alignment is crucial since it cannot be adjusted after stabilization with plates and screws. Recent advances in personalized medicine offer the opportunity to tailor surgical corrections to each patient’s unique anatomy and biomechanical profile. This study evaluates the benefits of 3D planning and patient-specific cutting guides over traditional 2D planning with standard implants for alignment correction procedures. Methods: We assessed limb alignment parameters pre- and postoperatively in patients with varus and valgus lower limb malalignment undergoing acute realignment surgery. The cohort included 23 opening-wedge high tibial osteotomies and 28 opening-wedge distal femur osteotomies. We compared the accuracy of postoperative alignment parameters between patients undergoing traditional 2D preoperative X-ray planning and those using 3D reconstructions of CT data. Outcome measures included mechanical axis deviation and tibiofemoral angles. Results: 3D reconstructions of computerized tomography data and patient-specific cutting guides significantly reduced the variation in postoperative limb alignment parameters relative to preoperative goals. In contrast, traditional 2D planning with standard non-custom implants resulted in higher deviations from the targeted alignment. Conclusions: Utilizing 3D CT reconstructions and patient-specific cutting guides enhances the accuracy of postoperative limb realignment compared to traditional 2D X-ray planning with standard non-custom implants. Patient-specific instrumentation and personalized approaches represent a key step toward precision orthopedic surgery, tailoring correction strategies to individual patient anatomy and potentially improving long-term joint health. This improvement may reduce the morbidity associated with lower limb malalignment and delay the onset of osteoarthritis. Level of Evidence: Therapeutic Level III. Full article
(This article belongs to the Special Issue Orthopedic Diseases: Advances in Limb Reconstruction)
Show Figures

Figure 1

14 pages, 2851 KiB  
Article
Guided Frontal Sinus Osteotomy: A Pilot Study of a Digital Protocol for “In-House” Manufacturing Surgical Cutting Guides
by Antonio Romano, Stefania Troise, Raffaele Spinelli, Vincenzo Abbate and Giovanni Dell’Aversana Orabona
J. Clin. Med. 2025, 14(9), 3141; https://doi.org/10.3390/jcm14093141 - 1 May 2025
Viewed by 514
Abstract
Objective: Frontal sinus surgery is still challenging for surgeons; the frontal osteotomy with the preparation of a frontal bone flap to access the sinus is usually hand-crafted by experienced surgeons. The objective of our study is to present a fully digital protocol for [...] Read more.
Objective: Frontal sinus surgery is still challenging for surgeons; the frontal osteotomy with the preparation of a frontal bone flap to access the sinus is usually hand-crafted by experienced surgeons. The objective of our study is to present a fully digital protocol for the manufacturing of “in-house” surgical cutting guides, customized to the patient’s anatomy, to perform precise frontal sinus osteotomy, showing the costs, times, and intraoperative complications reduction. Materials and Methods: A prospective study was conducted on 12 patients with complex pathologies involving the frontal sinus who underwent frontal sinus osteotomy in the Maxillofacial Surgery Unit of the Federico II University of Naples, from January 2021 to April 2025, considering the last surgery in November 2023. The same digital protocol to manufacture the surgical cutting guide was used for all the 12 patients. The first step was to upload the preoperative CT images in DICOM format to the software Mimics Medical to perform a rapid segmentation of the skull region of interest to create a 3D object and to identify the frontal sinus margins and the osteotomy lines. The second step was to realize the surgical cutting guide, incorporating the design of titanium plates to fix onto the skull in order to make a precise osteotomy. The final digital step was to export the cutting guide 3D object in the software “Formlab-Form 3B” to print the model with a specific resin. The model was then used during the surgery to perform the precise frontal osteotomy by piezo surgery. The clinical outcomes, in terms of complications and recurrences, were then recorded. Results: In all the patients, no intraoperative complications occurred; the median follow-up was 31.7 months and at one year of follow-up only one patient experienced a recurrence. The mean operative time was about 4 h, with a frontal osteotomy time of about 23 min. Digital protocol time was about 4 h while printing times were between 2 and 4 h. Conclusions: This “in-house” protocol seems to demonstrate that the use of intraoperative templates for the realization of the frontal sinus osteotomy reduces preoperative and intraoperative costs and times, reducing the risk of intraoperative complications, and also allows less experienced surgeons to perform the procedure safely. Obviously, this study is to be considered a “pilot study”, and other studies with large cohorts of patients will have to confirm these promising results. Full article
(This article belongs to the Special Issue Innovations in Maxillofacial Surgery)
Show Figures

Graphical abstract

16 pages, 6197 KiB  
Case Report
Limb-Sparing Surgery and Stifle Arthrodesis Using Patient-Specific 3D-Printed Guides and Endoprosthesis for Distal Femoral Chondrosarcoma in a Dog: A Case Report
by Enrico Panichi, Marco Tabbì, Gaetano Principato, Valentina Dal Magro, Fabio Valentini, Marco Currenti and Francesco Macrì
Animals 2025, 15(5), 673; https://doi.org/10.3390/ani15050673 - 26 Feb 2025
Viewed by 1506
Abstract
Limb-sparing techniques for appendicular primary bone tumors are still associated with a high rate of complications. Three-dimensional (3D)-printed patient-specific instruments could reduce these complications. The aim of this study is to describe a limb-sparing surgery using 3D-printed patient-specific guides (PSGs) and an endoprosthesis [...] Read more.
Limb-sparing techniques for appendicular primary bone tumors are still associated with a high rate of complications. Three-dimensional (3D)-printed patient-specific instruments could reduce these complications. The aim of this study is to describe a limb-sparing surgery using 3D-printed patient-specific guides (PSGs) and an endoprosthesis (PSE) to treat femoral chondrosarcoma in a dog. An eight-year-old female Golden Retriever presented with persistent lameness of the right hind limb, reluctance to move and difficulty in maintaining a standing position. Palpation of the right femur revealed an approximately 4 cm painful lesion. Cytological analysis of the needle aspiration supported the clinical and radiological suggestion of a cartilaginous bone neoplasm. Computed tomography (CT) scans suggested the presence of an aggressive lesion on the right distal femur. CT scans of the femur and tibia were then reconstructed using a bone tissue algorithm and processed with computer-aided design (CAD) software, which allowed for performing virtual surgical planning (VSP) and the fabrication of both the PSG and the PSE. Anti-inflammatory drugs and monoclonal antibodies were used for pain management while waiting for surgery. Adjuvant chemotherapy was also administered. An ostectomy of the distal third of the femur to completely remove the tumor was performed with the designed PSG, while the bone defect was filled with the designed PSE. Histopathological examination of the osteotomized bone segment confirmed a grade 2 central chondrosarcoma. There was no excessive tumor growth during the 28 days between the CT scans and surgery. Both PSG and PSE fitted perfectly to the bone surfaces. PSG eliminated the need for intraoperative imaging and ensured a faster and more accurate osteotomy. PSE optimized load sharing and eliminated the complications of the commercial endoprosthesis, such as incongruity and the need for manual intraoperative adjustment. Overall, the use of VSP, 3D-printed PSG and PSE significantly reduced surgical time, risk of infection and intra- and postoperative complications. Full article
(This article belongs to the Section Veterinary Clinical Studies)
Show Figures

Figure 1

10 pages, 7325 KiB  
Technical Note
The Panflute Technique: Novel 3D-Printed Patient Specific Instrumentation to Guide Curved Intra-Articular Osteotomies for Tibial Plateau Malunions
by Nick Assink, Cornelia W. Binnekamp, Hugo C. van der Veen, Job N. Doornberg, Frank F. A. IJpma and Peter A. J. Pijpker
J. Clin. Med. 2024, 13(20), 6175; https://doi.org/10.3390/jcm13206175 - 17 Oct 2024
Cited by 1 | Viewed by 1144
Abstract
Background/Objectives: 3D patient-specific corrective osteotomies are optimized for use with oscillating saws, thereby rendering it incapable of executing curved osteotomies. The aim of this technical note is to introduce and evaluate the Panflute technique, which facilitates curved osteotomies with precise depth control [...] Read more.
Background/Objectives: 3D patient-specific corrective osteotomies are optimized for use with oscillating saws, thereby rendering it incapable of executing curved osteotomies. The aim of this technical note is to introduce and evaluate the Panflute technique, which facilitates curved osteotomies with precise depth control for intra-articular corrective osteotomies in posttraumatic tibial plateau malunions. Methods: A 33-year-old male patient with an intra-articular malunion was treated one year after index surgery of a lateral split-depression tibial plateau fracture with the Panflute technique. The guide design allowed for multiple drill trajectories in a curved path, recreating the original fracture lines. Cylindrical drill tubes in the guide were tailored to match bone trajectory length. This resulted in a patient-specific Panflute-like design enabling precise depth control, safeguarding posterior neurovascular structures. Secondly, the recreated fragment was reduced with a reduction guide, applied to the plate in situ, to facilitate reposition using the plate as tool and reference. Results: The procedure went without technical drawbacks or surgical complications. Postoperative assessment showed that repositioning of the osteotomized articular fragment was performed accurately: pre- to postoperative translational corrections were 5.4 to 0.5 mm posterior displacement for AP deformity (x-axis); 2.9 to 1.0 mm lateral to medial reduction (y-axis); and 5.9 to 0.6 mm cranial-caudal correction (z-axis). Clinically, at 3 months, the fracture united, the patient regained full flexion, and valgus defect-laxity resolved. Conclusions: The presented Panflute-osteotomy guide allows for a pre-planned curved osteotomy. Additionally, for every drill trajectory, the depth could be controlled. The proposed method may expand our surgical armamentarium of patient-specific 3D techniques and solutions for complex intra-articular osteotomies. Full article
(This article belongs to the Section Orthopedics)
Show Figures

Figure 1

19 pages, 6533 KiB  
Article
Personalised High Tibial Osteotomy Surgery Is Accurate: An Assessment Using 3D Distance Mapping
by Andrea Varaschin, Harinderjit Singh Gill, Stefano Zaffagnini, Alberto Leardini, Maurizio Ortolani, Fabio Norvillo, Alisdair MacLeod, Giacomo Dal Fabbro, Giorgio Cassiolas, Alberto Grassi and Claudio Belvedere
Appl. Sci. 2024, 14(19), 9033; https://doi.org/10.3390/app14199033 - 6 Oct 2024
Cited by 1 | Viewed by 2559
Abstract
Early-stage knee osteoarthritis is often suitable for treatment with high tibial osteotomy (HTO). This is an effective joint-preserving treatment, resulting in good postoperative outcomes. To overcome the limitations of traditional HTO, the surgical technique and correction accuracy can be enhanced by personalised procedures [...] Read more.
Early-stage knee osteoarthritis is often suitable for treatment with high tibial osteotomy (HTO). This is an effective joint-preserving treatment, resulting in good postoperative outcomes. To overcome the limitations of traditional HTO, the surgical technique and correction accuracy can be enhanced by personalised procedures using three-dimensional digital planning and metal additive manufacturing, The purpose of this clinical trial study was to evaluate the three-dimensional accuracy of a new personalised HTO procedure, using modern imaging techniques, 3D modelling, and distance map analysis (DMA). Twenty-five patients were treated with the personalised HTO procedure. Before surgery and after 6 months, they underwent clinical evaluation scoring, radiographic imaging, and computed-tomography scanning to generate morphological models. Specifically, preoperative tibia models were used to plan the tibia correction and the design and position of the fixation plate. Preoperative, planned, and postoperative models were imported in computer-aided and designing software (Geomagic ControlTM 2014, 3D Systems, Rock Hill, SC, USA) for DMA implementation to assess geometrical differences between model surfaces. A very good reproduction of the planned tibia morphology was achieved postoperatively (average differences between −0.9 mm and 1.4 mm). DMA values associated with fixation-plate deformation were less than 1 mm, similar to those for plate-to-tibia surface-contour matching. Overall, personalised digitally planned HTO utilising three-dimensional printed surgical guides and plates enables accurate planned correction and plate placement. Full article
Show Figures

Figure 1

18 pages, 15761 KiB  
Article
Evaluation of the Dimensional Accuracy of Robot-Guided Laser Osteotomy in Reconstruction with Patient-Specific Implants—An Accuracy Study of Digital High-Tech Procedures
by Bilal Msallem, Lara Veronesi, Michel Beyer, Florian S. Halbeisen, Michaela Maintz, Adrian Franke, Paula Korn, Adrian Dragu and Florian M. Thieringer
J. Clin. Med. 2024, 13(12), 3594; https://doi.org/10.3390/jcm13123594 - 19 Jun 2024
Cited by 5 | Viewed by 1976
Abstract
Background/Objective: With the rapid advancement in surgical technologies, new workflows for mandibular reconstruction are constantly being evaluated. Cutting guides are extensively employed for defining osteotomy planes but are prone to errors during fabrication and positioning. A virtually defined osteotomy plane and drilling [...] Read more.
Background/Objective: With the rapid advancement in surgical technologies, new workflows for mandibular reconstruction are constantly being evaluated. Cutting guides are extensively employed for defining osteotomy planes but are prone to errors during fabrication and positioning. A virtually defined osteotomy plane and drilling holes in robotic surgery minimize potential sources of error and yield highly accurate outcomes. Methods: Ten mandibular replicas were evaluated after cutting-guided saw osteotomy and robot-guided laser osteotomy following reconstruction with patient-specific implants. The descriptive data analysis summarizes the mean, standard deviation (SD), median, minimum, maximum, and root mean square (RMS) values of the surface comparison for 3D printed models regarding trueness and precision. Results: The saw group had a median trueness RMS value of 2.0 mm (SD ± 1.7) and a precision of 1.6 mm (SD ± 1.4). The laser group had a median trueness RMS value of 1.2 mm (SD ± 1.1) and an equal precision of 1.6 mm (SD ± 1.4). These results indicate that robot-guided laser osteotomies have a comparable accuracy to cutting-guided saw osteotomies, even though there was a lack of statistical significance. Conclusions: Despite the limited sample size, this digital high-tech procedure has been shown to be potentially equivalent to the conventional osteotomy method. Robotic surgery and laser osteotomy offers enormous advantages, as they enable the seamless integration of precise virtual preoperative planning and exact execution in the human body, eliminating the need for surgical guides in the future. Full article
(This article belongs to the Special Issue Clinical Advances in Plastic Surgery)
Show Figures

Figure 1

15 pages, 5000 KiB  
Case Report
Patient-Specific 3D-Printed Osteotomy Guides and Titanium Plates for Distal Femoral Deformities in Dogs with Lateral Patellar Luxation
by Enrico Panichi, Fulvio Cappellari, Ekaterina Burkhan, Gaetano Principato, Marco Currenti, Marco Tabbì and Francesco Macrì
Animals 2024, 14(6), 951; https://doi.org/10.3390/ani14060951 - 19 Mar 2024
Cited by 4 | Viewed by 2955
Abstract
The aim of this study was to describe the diagnosis and treatment of grade IV lateral patellar luxation (LPL) in two adult large breed dogs with complex femoral deformities using patient-specific three-dimensionally (3D) printed osteotomy guides and implants. Computed tomography (CT) scans were [...] Read more.
The aim of this study was to describe the diagnosis and treatment of grade IV lateral patellar luxation (LPL) in two adult large breed dogs with complex femoral deformities using patient-specific three-dimensionally (3D) printed osteotomy guides and implants. Computed tomography (CT) scans were obtained for virtual surgical planning (VSP) using computer-aided design (CAD) software, which allowed for 3D reconstruction and manipulation of the femoral deformities, providing a preoperative view of the correction. Of the two patients, one was affected bilaterally and the other unilaterally, but both dogs were from the same litter. Therefore, the healthy femur of the unilaterally affected patient was used as the physiological reference for the virtual surgical correction. Three distal femoral trapezoid osteotomies (DF-TO) followed by reduction and internal fixation with plates were performed using patient-specific 3D-printed osteotomy guides and implants. This type of osteotomy permitted correction of procurvatum in all the femurs to increase knee extension, raise the dog’s lumbar spine and correct the kyphosis. Preoperative, expected and postoperative femoral angles were compared to evaluate the efficacy of virtual surgical planning and the outcome of surgical correction. Radiographic follow-up, passive range of motion and functional recovery were recorded. There were no major complications requiring revision surgery. Significant clinical improvement was observed in both patients. This study suggests that the treatment used represents a viable surgical alternative to restore limb alignment in patients with complex femoral deformities. Full article
Show Figures

Figure 1

14 pages, 2389 KiB  
Case Report
Custom CAD/CAM Peek Implants for Complex Orbitocranial Reconstruction: Our Experience with 15 Patients
by Cristina Cárdenas-Serres, Fernando Almeida-Parra, Anna María Simón-Flors, Patricia de Leyva-Moreno, Álvaro Ranz-Colio, Luis Ley-Urzaiz and Julio Acero-Sanz
J. Clin. Med. 2024, 13(3), 695; https://doi.org/10.3390/jcm13030695 - 25 Jan 2024
Cited by 8 | Viewed by 2105
Abstract
Bone defects within the cranio-orbital complex present unique challenges in terms of surgical planning and reconstruction. This article presents a novel approach using PEEK material and advanced surgical technologies to address these challenges. A retrospective analysis of 15 patients who underwent craniofacial reconstruction [...] Read more.
Bone defects within the cranio-orbital complex present unique challenges in terms of surgical planning and reconstruction. This article presents a novel approach using PEEK material and advanced surgical technologies to address these challenges. A retrospective analysis of 15 patients who underwent craniofacial reconstruction using patient-specific polyetheretherketone (PEEK) implants between 2016 and 2021 was carried out. Comprehensive preoperative planning was performed, utilizing advanced imaging techniques and specialized software for virtual surgical planning. Patient-specific PEEK PSIs were designed and manufactured based on the preoperative plan. Intraoperative navigation was used to guide the surgical procedure, enabling precise osteotomy and optimal implant placement. This article describes the step-by-step process and the tools utilized in each phase. The etiologies were as follows: meningioma in seven cases, benign lesions in five cases, malignant tumors in two cases, and trauma sequelae in one case. In all cases, 3D-printed PEEK implants were utilized to achieve precise reconstruction. No major complications were described. In one case, an implant replacement was needed with successful outcomes. Our study demonstrates the feasibility and effectiveness of using PEEK patient-specific implants for personalized craniofacial reconstruction. The combination of advanced imaging, virtual planning, and CAD-CAM technology contributes to improved surgical outcomes in terms of oncologic margin control, functional restoration, and aesthetic results. Full article
Show Figures

Figure 1

10 pages, 1652 KiB  
Article
Preclinical Application of Augmented Reality in Pediatric Craniofacial Surgery: An Accuracy Study
by Federica Ruggiero, Laura Cercenelli, Nicolas Emiliani, Giovanni Badiali, Mirko Bevini, Mino Zucchelli, Emanuela Marcelli and Achille Tarsitano
J. Clin. Med. 2023, 12(7), 2693; https://doi.org/10.3390/jcm12072693 - 4 Apr 2023
Cited by 16 | Viewed by 3042
Abstract
Background: Augmented reality (AR) allows the overlapping and integration of virtual information with the real environment. The camera of the AR device reads the object and integrates the virtual data. It has been widely applied to medical and surgical sciences in recent years [...] Read more.
Background: Augmented reality (AR) allows the overlapping and integration of virtual information with the real environment. The camera of the AR device reads the object and integrates the virtual data. It has been widely applied to medical and surgical sciences in recent years and has the potential to enhance intraoperative navigation. Materials and methods: In this study, the authors aim to assess the accuracy of AR guidance when using the commercial HoloLens 2 head-mounted display (HMD) in pediatric craniofacial surgery. The Authors selected fronto-orbital remodeling (FOR) as the procedure to test (specifically, frontal osteotomy and nasal osteotomy were considered). Six people (three surgeons and three engineers) were recruited to perform the osteotomies on a 3D printed stereolithographic model under the guidance of AR. By means of calibrated CAD/CAM cutting guides with different grooves, the authors measured the accuracy of the osteotomies that were performed. We tested accuracy levels of ±1.5 mm, ±1 mm, and ±0.5 mm. Results: With the HoloLens 2, the majority of the individuals involved were able to successfully trace the trajectories of the frontal and nasal osteotomies with an accuracy level of ±1.5 mm. Additionally, 80% were able to achieve an accuracy level of ±1 mm when performing a nasal osteotomy, and 52% were able to achieve an accuracy level of ±1 mm when performing a frontal osteotomy, while 61% were able to achieve an accuracy level of ±0.5 mm when performing a nasal osteotomy, and 33% were able to achieve an accuracy level of ±0.5 mm when performing a frontal osteotomy. Conclusions: despite this being an in vitro study, the authors reported encouraging results for the prospective use of AR on actual patients. Full article
(This article belongs to the Section Otolaryngology)
Show Figures

Figure 1

11 pages, 7572 KiB  
Case Report
Virtual Surgical Planning, 3D-Printing and Customized Bone Allograft for Acute Correction of Severe Genu Varum in Children
by Giulia Alessandri, Leonardo Frizziero, Gian Maria Santi, Alfredo Liverani, Dante Dallari, Leonardo Vivarelli, Giovanni Luigi Di Gennaro, Diego Antonioli, Grazia Chiara Menozzi, Alessandro Depaoli, Gino Rocca and Giovanni Trisolino
J. Pers. Med. 2022, 12(12), 2051; https://doi.org/10.3390/jpm12122051 - 12 Dec 2022
Cited by 15 | Viewed by 2498
Abstract
Complex deformities of lower limbs are frequent in children with genetic or metabolic skeletal disorders. Early correction is frequently required, but it is technically difficult and burdened by complications and recurrence. Herein, we described the case of a 7-year-old girl affected by severe [...] Read more.
Complex deformities of lower limbs are frequent in children with genetic or metabolic skeletal disorders. Early correction is frequently required, but it is technically difficult and burdened by complications and recurrence. Herein, we described the case of a 7-year-old girl affected by severe bilateral genu varum due to spondyloepiphyseal dysplasia. The patient was treated by patient-specific osteotomies and customized structural wedge allograft using Virtual Surgical Planning (VSP) and 3D-printed patient-specific instrumentation (PSI). The entire process was performed through an in-hospital 3D-printing Point-of-Care (POC). VSP and 3D-printing applied to pediatric orthopedic surgery may allow personalization of corrective osteotomies and customization of structural allografts by using low-cost in-hospital POC. However, optimal and definitive alignment is rarely achieved in such severe deformities in growing skeleton through a single operation. Full article
Show Figures

Figure 1

12 pages, 3235 KiB  
Article
Accuracy of a Three-Dimensional (3D)-Printed Patient-Specific (PS) Femoral Osteotomy Guide: A Computed Tomography (CT) Study
by Maria Moralidou, Anna Di Laura, Johann Henckel, Harry Hothi and Alister James Hart
Bioengineering 2022, 9(11), 667; https://doi.org/10.3390/bioengineering9110667 - 8 Nov 2022
Cited by 3 | Viewed by 2512
Abstract
Femoral neck osteotomy creates a critical anatomical landmark for surgeons performing primary Total Hip Arthroplasty (THA); it affects the final height and position of the femoral component. Patient Specific Instrumentation (PSI) has been developed to guide the osteotomy. We aimed to assess the [...] Read more.
Femoral neck osteotomy creates a critical anatomical landmark for surgeons performing primary Total Hip Arthroplasty (THA); it affects the final height and position of the femoral component. Patient Specific Instrumentation (PSI) has been developed to guide the osteotomy. We aimed to assess the accuracy of a patient-specific (PS) femoral osteotomy guide in primary THA using three-dimensional (3D) computed tomography (CT) analysis. We included pre- and post-operative CT data of 103 THAs. All patients underwent 3D planning to define the optimal femoral neck osteotomy level. Our primary objective was to quantify the discrepancy between the achieved and planned osteotomy level; our secondary objective was to evaluate the clinical outcome. The median (Interquartile Range—IQR) discrepancy between the achieved and planned osteotomy level was 0.3 mm (−1 mm to 2 mm). We found a strong positive correlation between the planned and achieved osteotomy level (R2 = 0.9, p < 0.001). A satisfactory clinical outcome was recorded. Our findings suggest that surgeons can use 3D-printed PS guides to achieve a femoral neck osteotomy with a high level of accuracy to the plan. Full article
Show Figures

Graphical abstract

16 pages, 2926 KiB  
Systematic Review
Custom-Made Devices Represent a Promising Tool to Increase Correction Accuracy of High Tibial Osteotomy: A Systematic Review of the Literature and Presentation of Pilot Cases with a New 3D-Printed System
by Stefano Zaffagnini, Giacomo Dal Fabbro, Claudio Belvedere, Alberto Leardini, Silvio Caravelli, Gian Andrea Lucidi, Piero Agostinone, Massimiliano Mosca, Maria Pia Neri and Alberto Grassi
J. Clin. Med. 2022, 11(19), 5717; https://doi.org/10.3390/jcm11195717 - 27 Sep 2022
Cited by 12 | Viewed by 3162
Abstract
Background: The accuracy of the coronal alignment corrections using conventional high tibial osteotomy (HTO) falls short, and multiplanar deformities of the tibia require consideration of both the coronal and sagittal planes. Patient-specific instrumentations have been introduced to improve the control of the correction. [...] Read more.
Background: The accuracy of the coronal alignment corrections using conventional high tibial osteotomy (HTO) falls short, and multiplanar deformities of the tibia require consideration of both the coronal and sagittal planes. Patient-specific instrumentations have been introduced to improve the control of the correction. Clear evidence about customized devices for HTO and their correction accuracy lacks. Methods: The databases PUBMED and EMBASE were systematically screened for human and cadaveric studies about the use of customized devices for high tibial osteotomy and their outcomes concerning correction accuracy. Furthermore, a 3D-printed customized system for valgus HTO with three pilot cases at one-year follow-up was presented. Results: 28 studies were included. The most commonly used custom-made devices for HTO were found to be cutting guides. Reported differences between the achieved and targeted correction of hip-knee-ankle angle and the posterior tibial slope were 3° or under. The three pilot cases that underwent personalized HTO with a new 3D-printed device presented satisfactory alignment and clinical outcomes at one-year follow-up. Conclusion: The available patient-specific devices described in the literature, including the one used in the preliminary cases of the current study, showed promising results in increasing the accuracy of correction in HTO procedure. Full article
(This article belongs to the Section Orthopedics)
Show Figures

Figure 1

10 pages, 2648 KiB  
Article
A Two-Step Approach for 3D-Guided Patient-Specific Corrective Limb Osteotomies
by Nick Assink, Anne M. L. Meesters, Kaj ten Duis, Jorrit S. Harbers, Frank F. A. IJpma, Hugo C. van der Veen, Job N. Doornberg, Peter A. J. Pijpker and Joep Kraeima
J. Pers. Med. 2022, 12(9), 1458; https://doi.org/10.3390/jpm12091458 - 6 Sep 2022
Cited by 11 | Viewed by 3878
Abstract
Background: Corrective osteotomy surgery for long bone anomalies can be very challenging since deformation of the bone is often present in three dimensions. We developed a two-step approach for 3D-planned corrective osteotomies which consists of a cutting and reposition guide in combination with [...] Read more.
Background: Corrective osteotomy surgery for long bone anomalies can be very challenging since deformation of the bone is often present in three dimensions. We developed a two-step approach for 3D-planned corrective osteotomies which consists of a cutting and reposition guide in combination with a conventional osteosynthesis plate. This study aimed to assess accuracy of the achieved corrections using this two-step technique. Methods: All patients (≥12 years) treated for post-traumatic malunion with a two-step 3D-planned corrective osteotomy within our center in 2021 were prospectively included. Three-dimensional virtual models of the planned outcome and the clinically achieved outcome were obtained and aligned. Postoperative evaluation of the accuracy of performed corrections was assessed by measuring the preoperative and postoperative alignment error in terms of angulation, rotation and translation. Results: A total of 10 patients were included. All corrective osteotomies were performed according to the predetermined surgical plan without any complications. The preoperative deformities ranged from 7.1 to 27.5° in terms of angulation and 5.3 to 26.1° in terms of rotation. The achieved alignment deviated on average 2.1 ± 1.0 and 3.4 ± 1.6 degrees from the planning for the angulation and rotation, respectively. Conclusions: A two-step approach for 3D-guided patient-specific corrective limb osteotomies is reliable, feasible and accurate. Full article
Show Figures

Figure 1

Back to TopTop