Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (7)

Search Parameters:
Keywords = micro-synchrophasors

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
22 pages, 2109 KB  
Article
Dynamic Characterization of an Industrial Electrical Network Using MicroPMU Data
by Julio Cesar Ramírez Acero, Ricardo Isaza-Ruget and Javier Rosero-García
Appl. Sci. 2026, 16(3), 1267; https://doi.org/10.3390/app16031267 - 27 Jan 2026
Cited by 1 | Viewed by 416
Abstract
The growing penetration of power electronics and nonlinear loads in industrial electrical networks has increased the dynamic complexity of these systems, exceeding the analysis capabilities of traditional approaches based on quasi-stationary models. In this context, this paper presents a methodology for the dynamic [...] Read more.
The growing penetration of power electronics and nonlinear loads in industrial electrical networks has increased the dynamic complexity of these systems, exceeding the analysis capabilities of traditional approaches based on quasi-stationary models. In this context, this paper presents a methodology for the dynamic characterization of an industrial electrical network based on high-resolution synchrophasor measurements obtained using a microPMU. The proposed approach is based on the identification of a linear dynamic model in state space using subspace techniques based on real data recorded during a short-duration transient event. The results show that the identified model is capable of adequately capturing local underdamped dynamics and reproducing the temporal response observed in the measurements. This evidences the presence of dynamic modes associated with the interaction between the network and power electronics-based devices. Similarly, the stability analysis of the identified model demonstrates its consistency and robust gains in temporal variations within the analysis window. Overall, the results confirm that the combination of microPMU and data-based modeling techniques is an effective tool for improving dynamic observability and understanding the transient behavior of industrial power grids, complementing classical analysis and simulation methods. Full article
(This article belongs to the Special Issue Research on and Application of Power Systems)
Show Figures

Figure 1

19 pages, 8178 KB  
Article
SpectralNet-Enabled Root Cause Analysis of Frequency Anomalies in Solar Grids Using μPMU
by Arnabi Modak, Maitreyee Dey, Preeti Patel and Soumya Prakash Rana
Energies 2026, 19(1), 268; https://doi.org/10.3390/en19010268 - 4 Jan 2026
Viewed by 695
Abstract
The rapid integration of solar power into distribution grids has intensified challenges related to frequency instability caused by fluctuating renewable generation. These unexpected frequency variations are difficult to capture using traditional or supervised methods because they emerge from nonlinear, rapidly changing inverter grid [...] Read more.
The rapid integration of solar power into distribution grids has intensified challenges related to frequency instability caused by fluctuating renewable generation. These unexpected frequency variations are difficult to capture using traditional or supervised methods because they emerge from nonlinear, rapidly changing inverter grid interactions and often lack labelled examples. To address this, the present work introduces a unique, frequency-centric framework for unsupervised detection and root cause analysis of grid anomalies using high-resolution micro-Phasor Measurement Unit (μPMU) data. Unlike previous studies that focus primarily on voltage phasors or rely on predefined event labels, this work employs SpectralNet, a deep spectral clustering approach, integrated with autoencoder-based feature learning to model the nonlinear interactions between frequency, ROCOF, voltage, and current. These methods are particularly effective for unexpected frequency variations because they learn intrinsic, hidden structures directly from the data and can group abnormal frequency behavior without prior knowledge of event types. The proposed model autonomously identifies distinct root causes such as unbalanced loads, phase-specific faults, and phase imbalances behind hazardous frequency deviations. Experimental validation on a real solar-integrated distribution feeder in the UK demonstrates that the framework achieves superior cluster compactness and interpretability compared to traditional methods like K-Means, GMM, and Fuzzy C-Means. The findings highlight SpectralNet’s capability to uncover subtle, nonlinear patterns in μPMU data, offering an adaptive, data-driven tool for enhancing grid stability and situational awareness in renewable-rich power systems. Full article
Show Figures

Figure 1

25 pages, 7129 KB  
Article
Smart Monitoring of Microgrid-Integrated Renewable-Energy-Powered Electric Vehicle Charging Stations Using Synchrophasor Technology
by Deepa B, Santoshkumar Hampannavar and Swapna Mansani
World Electr. Veh. J. 2024, 15(10), 432; https://doi.org/10.3390/wevj15100432 - 25 Sep 2024
Cited by 4 | Viewed by 2847
Abstract
With the growing concern over climate change and energy security, the Government of India expedited enhancing the share of renewable energy (RE) derived from solar, wind and biomass sources within the energy blend. In this paper, a techno-economic and environmental analysis of a [...] Read more.
With the growing concern over climate change and energy security, the Government of India expedited enhancing the share of renewable energy (RE) derived from solar, wind and biomass sources within the energy blend. In this paper, a techno-economic and environmental analysis of a microgrid-integrated electric vehicle charging stations fueled by renewable energy is proposed for a typical area in the State of Karnataka, South India. The power transaction with the grid and the sell-back price to the national grid were investigated. Carbon emissions were also assessed, and 128,406 CO2 kg/Yr can be saved in the grid-connected mode. Also, in this work, different scenarios such as injecting active power, reactive power, and active and reactive power, and injecting active and absorbing reactive power to the grid are comprehensively assessed. Out of four types, type 3 (inject real and reactive power) provides significant reduction in power losses by up to 80.99%. The synchrophasor-technology-based monitoring method is adopted in order to enhance the microgrid system’s overall performance. The execution times for different cases with distributed generators (DGs) and electric vehicle charging stations (EVCSs) for conventional systems and micro-phasor measurement units (µPMU) were observed to be 19.07 s and 5.64 s, respectively, which is well accepted in the case of online monitoring. Full article
(This article belongs to the Special Issue Electric Vehicles and Smart Grid Interaction)
Show Figures

Figure 1

16 pages, 2959 KB  
Article
Multi-Source Information Fusion Technology and Its Application in Smart Distribution Power System
by Xi He, Heng Dong, Wanli Yang and Wei Li
Sustainability 2023, 15(7), 6170; https://doi.org/10.3390/su15076170 - 3 Apr 2023
Cited by 40 | Viewed by 5516
Abstract
Compared to traditional measurement devices, the micro-synchrophasor measurement unit (D-PMU or μPMU) in the distribution power system has great differences in data acquisition frequency, data format, data dimension, time-stamped information, etc. Hence, it is imperative to research the integration mechanism of heterogeneous data [...] Read more.
Compared to traditional measurement devices, the micro-synchrophasor measurement unit (D-PMU or μPMU) in the distribution power system has great differences in data acquisition frequency, data format, data dimension, time-stamped information, etc. Hence, it is imperative to research the integration mechanism of heterogeneous data from multiple sources. Based on the analysis of the current technology of multi-source information fusion, this paper proposes a novel approach, which considers two aspects: the interoperability of multi-source data and the real-time processing of large-scale streaming data. To solve the problem of data interoperability, we have modified the model of D-PMU data and established a unified information model. Meanwhile, an advanced distributed processing technology has been deployed to solve the problem of real-time processing of streaming data. Based on this approach, a smart distribution power system wide-area measurement and control station can be established, and the correctness and practicality of the proposed method are verified by an on-field project. Full article
Show Figures

Figure 1

18 pages, 7259 KB  
Article
An Islanding Detection Technique for Inverter-Based Distributed Generation in Microgrids
by Mazaher Karimi, Mohammad Farshad, Qiteng Hong, Hannu Laaksonen and Kimmo Kauhaniemi
Energies 2021, 14(1), 130; https://doi.org/10.3390/en14010130 - 29 Dec 2020
Cited by 41 | Viewed by 4657
Abstract
This article proposes a new passive islanding detection technique for inverter-based distributed generation (DG) in microgrids based on local synchrophasor measurements. The proposed method utilizes the voltage and current phasors measured at the DG connection point (point of connection, PoC). In this paper, [...] Read more.
This article proposes a new passive islanding detection technique for inverter-based distributed generation (DG) in microgrids based on local synchrophasor measurements. The proposed method utilizes the voltage and current phasors measured at the DG connection point (point of connection, PoC). In this paper, the rate of change of voltages and the ratio of the voltage and current magnitudes (VoI index) at the PoC are monitored using micro-phasor measurement units. The developed local measurements based decentralized islanding detection technique is based on the VoI index in order to detect any kind of utility grid frequency fluctuations or oscillations and distinguishing them from islanding condition. The simulation studies confirm that the proposed scheme is accurate, robust, fast, and simple to implement for inverter-based DGs. Full article
(This article belongs to the Special Issue Smart Grids and Flexible Energy Systems)
Show Figures

Figure 1

31 pages, 15084 KB  
Article
Islanding Detection Using a Micro-Synchrophasor for Distribution Systems with Distributed Generation
by Karthikeyan Subramanian and Ashok Kumar Loganathan
Energies 2020, 13(19), 5180; https://doi.org/10.3390/en13195180 - 5 Oct 2020
Cited by 21 | Viewed by 3340
Abstract
Distributed Generation (DG) has changed the power generation system to small-scale instead of large-scale generation. The demanding issue with the interconnection of DG is the detection of unintended islanding in a network. Several methods proposed in the literature show drawbacks such as high [...] Read more.
Distributed Generation (DG) has changed the power generation system to small-scale instead of large-scale generation. The demanding issue with the interconnection of DG is the detection of unintended islanding in a network. Several methods proposed in the literature show drawbacks such as high non-detection zones (NDZ) and higher tripping time. In this paper, the IEEE 13 bus distribution network with DGs like wind and solar power plants is integrated at two buses. Islanding is detected by utilizing data from a micro-synchrophasor located at the distribution grid and the DG. The micro-synchrophasor-based unintended islanding detection algorithm is based on parameters such as voltage, rate of change of voltage, frequency, rate of change of frequency, voltage phase angle difference and the rate of change of the voltage phase angle difference between the utility and the islanded grid. The proposed islanding detection algorithm discriminates between islanding and non-islanding conditions and is highly efficient under zero power mismatch conditions. The proposed method has null NDZ and satisfies the IEEE 1547 standard for DG tripping time. The effectiveness of the proposed IDM was verified when there are multiple DGs in the islanded grid. Also, the proposed method does not require additional hardware as it can be incorporated in digital relays with synchrophasor functionality. Full article
Show Figures

Figure 1

21 pages, 3276 KB  
Article
Real-Time Simulation and Hardware-in-the-Loop Testbed for Distribution Synchrophasor Applications
by Matthias Stifter, Jose Cordova, Jawad Kazmi and Reza Arghandeh
Energies 2018, 11(4), 876; https://doi.org/10.3390/en11040876 - 10 Apr 2018
Cited by 19 | Viewed by 9086
Abstract
With the advent of Distribution Phasor Measurement Units (D-PMUs) and Micro-Synchrophasors (Micro-PMUs), the situational awareness in power distribution systems is going to the next level using time-synchronization. However, designing, analyzing, and testing of such accurate measurement devices are still challenging. Due to the [...] Read more.
With the advent of Distribution Phasor Measurement Units (D-PMUs) and Micro-Synchrophasors (Micro-PMUs), the situational awareness in power distribution systems is going to the next level using time-synchronization. However, designing, analyzing, and testing of such accurate measurement devices are still challenging. Due to the lack of available knowledge and sufficient history for synchrophasors’ applications at the power distribution level, the realistic simulation, and validation environments are essential for D-PMU development and deployment. This paper presents a vendor agnostic PMU real-time simulation and hardware-in-the-Loop (PMU-RTS-HIL) testbed, which helps in multiple PMUs validation and studies. The network of real and virtual PMUs was built in a full time-synchronized environment for PMU applications’ validation. The proposed testbed also includes an emulated communication network (CNS) layer to replicate bandwidth, packet loss and collisions conditions inherent to the PMUs data streams’ issues. Experimental results demonstrate the flexibility and scalability of the developed PMU-RTS-HIL testbed by producing large amounts of measurements under typical normal and abnormal distribution grid operation conditions. Full article
(This article belongs to the Special Issue Methods and Concepts for Designing and Validating Smart Grid Systems)
Show Figures

Graphical abstract

Back to TopTop