Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (29)

Search Parameters:
Keywords = magnetic tip fabrication

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
16 pages, 25399 KB  
Article
Coaxially Printed Electroablation Catheter for Magnetically Actuated Navigation and Localized Tissue Ablation
by Xiaonan Sun, Tong Wu, Fuqian Chen, Qingyu Yu, Binbin Zhang, Lelun Jiang and Yuanxi Zhang
Actuators 2026, 15(6), 289; https://doi.org/10.3390/act15060289 - 26 May 2026
Viewed by 478
Abstract
Magnetically actuated catheters have attracted increasing attention for minimally invasive interventions because they enable remote, non-contact steering in confined and tortuous anatomical environments. However, integrating magnetic actuation, electroablation capability, and high structural compliance into a single soft catheter remains challenging. Here, we present [...] Read more.
Magnetically actuated catheters have attracted increasing attention for minimally invasive interventions because they enable remote, non-contact steering in confined and tortuous anatomical environments. However, integrating magnetic actuation, electroablation capability, and high structural compliance into a single soft catheter remains challenging. Here, we present a coaxially printed magnetically actuated electroablation catheter (MEC). The MEC is fabricated via a coaxial 3D printing process, combining a highly flexible PDMS outer sheath with a continuously deformable eutectic gallium–indium (eGaIn) conductive core, followed by the distal assembly of a magnetic ring and a copper electrode. This structural design preserves intrinsic mechanical flexibility while maintaining stable electrical conductivity under bending deformation. To achieve active catheter steering, an eight-axis electromagnetic actuation system was developed to generate controllable magnetic fields for tip deflection and guidance. The MEC exhibited effective navigation and manipulation in maze traversal and selective navigation within a 3D-printed vascular model. Furthermore, ex vivo porcine liver and in vivo rat liver electroablation experiments verified that the MEC could be magnetically navigated to designated sites for localized electroablation. This work provides a new strategy for precise, minimally invasive ablation of target tissues in confined and difficult-to-access anatomical environments. Full article
(This article belongs to the Section Actuators for Medical Instruments)
Show Figures

Figure 1

23 pages, 6239 KB  
Article
Multifunctional PVDF/BaFe12O19 Composite Membranes: Filler-Controlled β-Phase Evolution, Thermal Behavior, Optical, Dielectric, and Magnetic Properties
by Alina Rabadanova, Abdulatip Shuaibov, Asiyat Magomedova, Nariman Alikhanov, Shikhgasan Ramazanov, Akhmed Amirov, Dinara Sobola, Samer Daradkeh, Tomáš Trčka, Kamaludin Abdulvakhidov, Arseniy Khrustalev and Farid Orudzhev
J. Compos. Sci. 2026, 10(5), 273; https://doi.org/10.3390/jcs10050273 - 19 May 2026
Viewed by 2048
Abstract
Multifunctional polymer–ferrite composites based on poly(vinylidene fluoride) (PVDF) and magnetic fillers are of increasing interest for applications requiring coupled electrical, dielectric, and magnetic responses. However, the relationship between magnetic filler concentration, PVDF phase composition, and the resulting multifunctional properties remains insufficiently understood. In [...] Read more.
Multifunctional polymer–ferrite composites based on poly(vinylidene fluoride) (PVDF) and magnetic fillers are of increasing interest for applications requiring coupled electrical, dielectric, and magnetic responses. However, the relationship between magnetic filler concentration, PVDF phase composition, and the resulting multifunctional properties remains insufficiently understood. In this work, PVDF/BaFe12O19 (PVDF/BaF) composite membranes containing 2–20 wt.% BaF were fabricated using a combined non-solvent and thermally induced phase-inversion (NIPS–TIPS) method. Structural evolution was analyzed by X-ray diffraction and quantitative FTIR spectroscopy, thermal behavior by differential scanning calorimetry, optical properties by diffuse reflectance spectroscopy, dielectric response in the frequency range 103–106 Hz, and magnetic characteristics by vibrating sample magnetometry. At moderate filler concentrations (2–10 wt.%), BaFe12O19 nanoparticles acted as effective β-phase nucleating centers, leading to electroactive phase fractions of 97.7–99.9% and a maximum β-phase content of 86.7% for PVDF/BaF10. At higher loadings (15–20 wt.%), particle agglomeration and restricted chain mobility promoted a transition toward α-phase-dominated crystallization. Thermal analysis indicated competing nucleation and confined crystallization processes, while optical and dielectric measurements revealed nonmonotonic changes associated with interfacial interactions and Maxwell–Wagner–Sillars polarization. Magnetic measurements showed a linear increase in saturation magnetization with filler concentration and a nonmonotonic coercivity dependence with a pronounced change near the critical agglomeration concentration. These results demonstrate that the multifunctional response of PVDF/BaFe12O19 membranes is governed by the interplay between β-phase nucleation, interfacial polarization, and magnetic particle interactions, with approximately 10 wt.% ferrite providing the most balanced electrical, dielectric, and magnetic characteristics. Full article
(This article belongs to the Section Polymer Composites)
Show Figures

Figure 1

16 pages, 5393 KB  
Article
High-Efficiency Fiber Edge Coupling for Silicon Nitride Integrated Photonics
by Sergey S. Avdeev, Aleksandr S. Baburin, Evgeniy V. Sergeev, Alexei B. Kramarenko, Arseniy V. Belyaev, Danil V. Kushnev, Kirill A. Buzaverov, Ilya A. Stepanov, Vladimir V. Echeistov, Ales S. Loginov, Sergey V. Bukatin, Ali Sh. Amiraslanov, Evgeniy S. Lotkov, Dmitriy A. Baklykov and Ilya A. Rodionov
Micromachines 2025, 16(12), 1401; https://doi.org/10.3390/mi16121401 - 12 Dec 2025
Cited by 5 | Viewed by 2631
Abstract
Photonic integrated circuits play a crucial role in almost every aspect of modern life, such as data storage, telecommunications, medical diagnostics, green energy, autonomous driving, agriculture, and high-performance computing. To fully harness their benefits, an efficient coupling mechanism is required to successfully launch [...] Read more.
Photonic integrated circuits play a crucial role in almost every aspect of modern life, such as data storage, telecommunications, medical diagnostics, green energy, autonomous driving, agriculture, and high-performance computing. To fully harness their benefits, an efficient coupling mechanism is required to successfully launch light into on-chip waveguides from fibers. This study introduces low-loss coupling strategies and their implementation for silicon nitride integrated photonics. Here we present an overview of coupling technologies, optimized designs, and a fabrication technique for inverse tapers, which enable effective coupling for both transverse-magnetic and transverse-electric modes. We measured the coupling losses of 0.15 dB for UHNA-7 fiber at 1550 nm per facet for single-mode 220 × 1200 nm waveguides. We also designed, fabricated, and experimentally characterized a multi-tip taper, yielding 1.5 dB per facet at 1550 nm with broadband stability over 1500–1600 nm. We believe that our approach is universal and can be used both for individual fiber and fiber arrays coupling and for subsequent assembly of fiber with a chip, ensuring minimal losses. Full article
(This article belongs to the Section A1: Optical MEMS and Photonic Microsystems)
Show Figures

Figure 1

25 pages, 9780 KB  
Article
Efficiency Optimization of PMSM-Type Elevator Machine: An Industrial Comparison
by Mucahit Soyaslan, Osman Eldogan, Ahmet Fenercioglu, Yusuf Avsar, Nurdogan Ceylan and Muhammed Salih Sarıkaya
Machines 2025, 13(3), 173; https://doi.org/10.3390/machines13030173 - 21 Feb 2025
Cited by 1 | Viewed by 4365
Abstract
This study presents the design, modeling, and prototyping of an external rotor permanent magnet synchronous motor (ER-PMSM) specifically for elevator traction systems. The external rotor design aims to surpass the efficiency of conventional inner rotor gearless elevator traction motors. A commercially available 4 [...] Read more.
This study presents the design, modeling, and prototyping of an external rotor permanent magnet synchronous motor (ER-PMSM) specifically for elevator traction systems. The external rotor design aims to surpass the efficiency of conventional inner rotor gearless elevator traction motors. A commercially available 4 kW inner rotor permanent magnet synchronous motor (IR-PMSM) was selected for comparative analysis. Critical parameters, including stator tooth tip thickness, slot tip radius, slot height, stator yoke height, stator tooth thickness, and the number of turns per phase, were optimized to enhance efficiency. The artificial bee colony (ABC) algorithm was utilized for the first time to determine the optimal configuration of an external rotor PMSM. The prototype was fabricated and subjected to rigorous testing using a dedicated electrical motor test setup. Comparative results demonstrated a significant improvement in efficiency for the ER-PMSM over the IR-PMSM, with the efficiency increasing from 72.5% to 84.67% at nominal operating conditions. Full article
Show Figures

Figure 1

25 pages, 3366 KB  
Review
An Overview of the R&D of Flywheel Energy Storage Technologies in China
by Xingjian Dai, Xiaoting Ma, Dongxu Hu, Jibing Duan and Haisheng Chen
Energies 2024, 17(22), 5531; https://doi.org/10.3390/en17225531 - 5 Nov 2024
Cited by 12 | Viewed by 8068
Abstract
The literature written in Chinese mainly and in English with a small amount is reviewed to obtain the overall status of flywheel energy storage technologies in China. The theoretical exploration of flywheel energy storage (FES) started in the 1980s in China. The experimental [...] Read more.
The literature written in Chinese mainly and in English with a small amount is reviewed to obtain the overall status of flywheel energy storage technologies in China. The theoretical exploration of flywheel energy storage (FES) started in the 1980s in China. The experimental FES system and its components, such as the flywheel, motor/generator, bearing, and power electronic devices, were researched around thirty years ago. About twenty organizations devote themselves to the R&D of FES technology, which is developing from theoretical and laboratory research to the stage of engineering demonstration and commercial application. After the research and accumulation in the past 30 years, the initial FES products were developed by some companies around 10 years ago. Today, the overall technical level of China’s flywheel energy storage is no longer lagging behind that of Western advanced countries that started FES R&D in the 1970s. The reported maximum tip speed of the new 2D woven fabric composite flywheel arrived at 900 m/s in the spin test. A steel alloy flywheel with an energy storage capacity of 125 kWh and a composite flywheel with an energy storage capacity of 10 kWh have been successfully developed. Permanent magnet (PM) motors with power of 250–1000 kW were designed, manufactured, and tested in many FES assemblies. The lower loss is carried out through innovative stator and rotor configuration, optimizing magnetic flux and winding arrangement for harmonic magnetic field suppression. Permanent magnetic bearings with high load ability up to 50–100 kN were developed both for a 1000 kW/16.7 kWh flywheel used for the drilling practice application in hybrid power of an oil well drilling rig and for 630 kW/125 kWh flywheels used in the 22 MW flywheel array applied to the flywheel and thermal power joint frequency modulation demonstration project. It is expected that the FES demonstration application power stations with a total cumulative capacity of 300 MW will be built in the next five years. Full article
(This article belongs to the Special Issue Flywheel Energy Storage Systems and Applications Ⅱ)
Show Figures

Figure 1

12 pages, 2217 KB  
Article
Characterization of a 3D Printed Endovascular Magnetic Catheter
by Mohammad Hasan Dad Ansari, Xuan Thao Ha, Mouloud Ourak, Gianni Borghesan, Veronica Iacovacci, Emmanuel Vander Poorten and Arianna Menciassi
Actuators 2023, 12(11), 409; https://doi.org/10.3390/act12110409 - 1 Nov 2023
Cited by 7 | Viewed by 4086
Abstract
Minimally invasive endovascular procedures rely heavily on catheter devices. However, traditional catheters lack active steering requiring considerable skill on the surgeon’s part to accurately position the tip. While catheter tips could be made steerable using tendon-driven and Pneumatic Artificial Muscle (PAM) approaches, remote [...] Read more.
Minimally invasive endovascular procedures rely heavily on catheter devices. However, traditional catheters lack active steering requiring considerable skill on the surgeon’s part to accurately position the tip. While catheter tips could be made steerable using tendon-driven and Pneumatic Artificial Muscle (PAM) approaches, remote magnetic actuation is uniquely suited for this task due to its safety, controllability, and intrinsic miniaturization capabilities. Soft composite magnetic materials feature embedding distributed magnetic microparticles compared with attaching discrete permanent magnets proving beneficial in steerability and control. This work demonstrates the fabrication of a soft hollow magnetic tip that can be attached to a catheter to make the assembly steerable. The catheter tip is extensively characterized in terms of bending hysteresis, bending force, and dynamic response. The catheter showed average hysteresis between 5% and 10% and bending forces up to 0.8 N. It also showed a good dynamic response by changing its bending angle in <200 ms under a step response. Full article
(This article belongs to the Special Issue Soft Actuators for Medical Robotics)
Show Figures

Figure 1

43 pages, 5028 KB  
Review
A Review of the Current State of Magnetic Force Microscopy to Unravel the Magnetic Properties of Nanomaterials Applied in Biological Systems and Future Directions for Quantum Technologies
by Robert Winkler, Miguel Ciria, Margaret Ahmad, Harald Plank and Carlos Marcuello
Nanomaterials 2023, 13(18), 2585; https://doi.org/10.3390/nano13182585 - 18 Sep 2023
Cited by 80 | Viewed by 10385
Abstract
Magnetism plays a pivotal role in many biological systems. However, the intensity of the magnetic forces exerted between magnetic bodies is usually low, which demands the development of ultra-sensitivity tools for proper sensing. In this framework, magnetic force microscopy (MFM) offers excellent lateral [...] Read more.
Magnetism plays a pivotal role in many biological systems. However, the intensity of the magnetic forces exerted between magnetic bodies is usually low, which demands the development of ultra-sensitivity tools for proper sensing. In this framework, magnetic force microscopy (MFM) offers excellent lateral resolution and the possibility of conducting single-molecule studies like other single-probe microscopy (SPM) techniques. This comprehensive review attempts to describe the paramount importance of magnetic forces for biological applications by highlighting MFM’s main advantages but also intrinsic limitations. While the working principles are described in depth, the article also focuses on novel micro- and nanofabrication procedures for MFM tips, which enhance the magnetic response signal of tested biomaterials compared to commercial nanoprobes. This work also depicts some relevant examples where MFM can quantitatively assess the magnetic performance of nanomaterials involved in biological systems, including magnetotactic bacteria, cryptochrome flavoproteins, and magnetic nanoparticles that can interact with animal tissues. Additionally, the most promising perspectives in this field are highlighted to make the reader aware of upcoming challenges when aiming toward quantum technologies. Full article
Show Figures

Figure 1

17 pages, 6715 KB  
Article
Additive Manufacturing of Co3Fe Nano-Probes for Magnetic Force Microscopy
by Robert Winkler, Michele Brugger-Hatzl, Lukas Matthias Seewald, David Kuhness, Sven Barth, Thomas Mairhofer, Gerald Kothleitner and Harald Plank
Nanomaterials 2023, 13(7), 1217; https://doi.org/10.3390/nano13071217 - 29 Mar 2023
Cited by 19 | Viewed by 5718
Abstract
Magnetic force microscopy (MFM) is a powerful extension of atomic force microscopy (AFM), which mostly uses nano-probes with functional coatings for studying magnetic surface features. Although well established, additional layers inherently increase apex radii, which reduce lateral resolution and also contain the risk [...] Read more.
Magnetic force microscopy (MFM) is a powerful extension of atomic force microscopy (AFM), which mostly uses nano-probes with functional coatings for studying magnetic surface features. Although well established, additional layers inherently increase apex radii, which reduce lateral resolution and also contain the risk of delamination, rendering such nano-probes doubtful or even useless. To overcome these limitations, we now introduce the additive direct-write fabrication of magnetic nano-cones via focused electron beam-induced deposition (FEBID) using an HCo3Fe(CO)12 precursor. The study first identifies a proper 3D design, confines the most relevant process parameters by means of primary electron energy and beam currents, and evaluates post-growth procedures as well. That way, highly crystalline nano-tips with minimal surface contamination and apex radii in the sub-15 nm regime are fabricated and benchmarked against commercial products. The results not only reveal a very high performance during MFM operation but in particular demonstrate virtually loss-free behavior after almost 8 h of continuous operation, thanks to the all-metal character. Even after more than 12 months of storage in ambient conditions, no performance loss is observed, which underlines the high overall performance of the here-introduced FEBID-based Co3Fe MFM nano-probes. Full article
(This article belongs to the Special Issue Preparation and Application of Nanowires: 2nd Edition)
Show Figures

Graphical abstract

11 pages, 3414 KB  
Article
All Fiber Vector Magnetometer Based on Nitrogen-Vacancy Center
by Man Zhao, Qijing Lin, Qingzhi Meng, Wenjun Shan, Liangquan Zhu, Yao Chen, Tao Liu, Libo Zhao and Zhuangde Jiang
Nanomaterials 2023, 13(5), 949; https://doi.org/10.3390/nano13050949 - 6 Mar 2023
Cited by 20 | Viewed by 8245
Abstract
Magnetometers based on nitrogen-vacancy (NV) centers in diamonds have promising applications in fields of living systems biology, condensed matter physics, and industry. This paper proposes a portable and flexible all-fiber NV center vector magnetometer by using fibers to substitute all conventional spatial optical [...] Read more.
Magnetometers based on nitrogen-vacancy (NV) centers in diamonds have promising applications in fields of living systems biology, condensed matter physics, and industry. This paper proposes a portable and flexible all-fiber NV center vector magnetometer by using fibers to substitute all conventional spatial optical elements, realizing laser excitation and fluorescence collection of micro-diamond with multi-mode fibers simultaneously and efficiently. An optical model is established to investigate multi-mode fiber interrogation of micro-diamond to estimate the optical performance of NV center system. A new analysis method is proposed to extract the magnitude and direction of the magnetic field, combining the morphology of the micro-diamond, thus realizing μm-scale vector magnetic field detection at the tip of the fiber probe. Experimental testing shows our fabricated magnetometer has a sensitivity of 0.73 nT/Hz1/2, demonstrating its feasibility and performance in comparison with conventional confocal NV center magnetometers. This research presents a robust and compact magnetic endoscopy and remote-magnetic measurement approach, which will substantially promote the practical application of magnetometers based on NV centers. Full article
Show Figures

Figure 1

12 pages, 2583 KB  
Article
A Piezoelectric Heterostructure Scavenging Mechanical Energy from Human Foot Strikes
by Wei He
Micromachines 2022, 13(8), 1353; https://doi.org/10.3390/mi13081353 - 20 Aug 2022
Cited by 9 | Viewed by 2856
Abstract
This paper presents a piezoelectric heterostructure for extracting mechanical energy from human foot strikes based on the impact of a moving block on the tips of the piezoelectric unimorph cantilevers. The use of the magnetic springs allows low-frequency and high-amplitude movements of the [...] Read more.
This paper presents a piezoelectric heterostructure for extracting mechanical energy from human foot strikes based on the impact of a moving block on the tips of the piezoelectric unimorph cantilevers. The use of the magnetic springs allows low-frequency and high-amplitude movements of the device. The piezoelectric unimorph cantilevers deform under a human foot strike on the pedal, and the piezoelectric elements in d31-mode produce output voltages. An analysis was conducted, and the working principle was stated. A prototype was fabricated to validate the feasibility of the proposed design. The experimental results show that the generated RMS voltage increases with human walking (running) speed. At the walking speed of 6 km/h, an average power of 36.26 μW is produced across a matching resistive load of 4 MΩ with an initial separating distance of 9 mm. Improvements of the device are possible, allowing an increase in the average power by increasing the number of piezoelectric unimorph cantilevers and using the piezoelectric materials with higher piezoelectric constants. Full article
Show Figures

Figure 1

14 pages, 8171 KB  
Article
Piezoelectric Energy Harvesting from Low-Frequency Vibrations Based on Magnetic Plucking and Indirect Impacts
by Michele Rosso, Alessandro Nastro, Marco Baù, Marco Ferrari, Vittorio Ferrari, Alberto Corigliano and Raffaele Ardito
Sensors 2022, 22(15), 5911; https://doi.org/10.3390/s22155911 - 8 Aug 2022
Cited by 27 | Viewed by 6959
Abstract
This work proposes a mono-axial piezoelectric energy harvester based on the innovative combination of magnetic plucking and indirect impacts, e.g., impacts happening on the package of the harvester. The harvester exploits a permanent magnet placed on a non-magnetic mass, free to move within [...] Read more.
This work proposes a mono-axial piezoelectric energy harvester based on the innovative combination of magnetic plucking and indirect impacts, e.g., impacts happening on the package of the harvester. The harvester exploits a permanent magnet placed on a non-magnetic mass, free to move within a predefined bounded region located in front of a piezoelectric bimorph cantilever equipped with a magnet as the tip mass. When the harvester is subjected to a low-frequency external acceleration, the moving mass induces an abrupt deflection and release of the cantilever by means of magnetic coupling, followed by impacts of the same mass against the harvester package. The combined effect of magnetic plucking and indirect impacts induces a frequency up-conversion. A prototype has been designed, fabricated, fastened to the wrist of a person by means of a wristband, and experimentally tested for different motion levels. By setting the magnets in a repulsive configuration, after 50 s of consecutive impacts induced by shaking, an energy of 253.41 μJ has been stored: this value is seven times higher compared to the case of harvester subjected to indirect impacts only, i.e., without magnetic coupling. This confirms that the combination of magnetic plucking and indirect impacts triggers the effective scavenging of electrical energy even from low-frequency non-periodical mechanical movements, such as human motion, while preserving the reliability of piezoelectric components. Full article
(This article belongs to the Special Issue Opportunities and Challenges in Energy Harvesting and Smart Sensors)
Show Figures

Figure 1

11 pages, 1970 KB  
Article
A Self-Assembly of Single Layer of Co Nanorods to Reveal the Magnetostatic Interaction Mechanism
by Hongyu Du, Min Zhang, Ke Yang, Baohe Li and Zhenhui Ma
Nanomaterials 2022, 12(14), 2499; https://doi.org/10.3390/nano12142499 - 21 Jul 2022
Cited by 4 | Viewed by 2365
Abstract
In this work, we report a self-assembly method to fabricate a single layer of Co nanorods to study their magnetostatic interaction behavior. The Co nanorods with cambered and flat tips were synthesized by using a solvothermal route and an alcohol–thermal method, respectively. Both [...] Read more.
In this work, we report a self-assembly method to fabricate a single layer of Co nanorods to study their magnetostatic interaction behavior. The Co nanorods with cambered and flat tips were synthesized by using a solvothermal route and an alcohol–thermal method, respectively. Both of them represent hard magnetic features. Co nanorods with cambered tips have an average diameter of 10 nm and length of 100 nm with coercivity of 6.4 kOe, and flat-tip nanorods with a 30 nm diameter and 100 nm length exhibit a coercivity of 4.9 kOe. They are further assembled on the surface of water in assistance of surfactants. The results demonstrate that the assembly type is dependent on the magnetic induction lines direction. For Co nanorods with flat tips, most of magnetic induction lines are parallel to the length direction, leading to an assembly that is tip to tip. For Co nanorods with cambered tips, they are prone to holding together side by side for their random magnetic induction lines. Under an applied field, the Co nanorods with flat tips can be further aligned into a single layer of Co nanorods. Our work gives a possible mechanism for the magnetic interaction of Co nanorods and provides a method to study their magnetic behavior. Full article
Show Figures

Graphical abstract

12 pages, 4447 KB  
Article
A Self-Flux-Biased NanoSQUID with Four NbN-TiN-NbN Nanobridge Josephson Junctions
by M. I. Faley and R. E. Dunin-Borkowski
Electronics 2022, 11(11), 1704; https://doi.org/10.3390/electronics11111704 - 27 May 2022
Cited by 5 | Viewed by 3244
Abstract
We report the development of a planar 4-Josephson-junction nanoscale superconducting quantum interference device (nanoSQUID) that is self-biased for optimal sensitivity without the application of a magnetic flux of Φ0/4. The nanoSQUID contains novel NbN-TiN-NbN nanobridge Josephson junctions (nJJs) with NbN current [...] Read more.
We report the development of a planar 4-Josephson-junction nanoscale superconducting quantum interference device (nanoSQUID) that is self-biased for optimal sensitivity without the application of a magnetic flux of Φ0/4. The nanoSQUID contains novel NbN-TiN-NbN nanobridge Josephson junctions (nJJs) with NbN current leads and electrodes of the nanoSQUID body connected by TiN nanobridges. The optimal superconducting transition temperature of ~4.8 K, superconducting coherence length of ~100 nm, and corrosion resistance of the TiN films ensure the hysteresis-free, reproducible, and long-term stability of nJJ and nanoSQUID operation at 4.2 K, while the corrosion-resistant NbN has a relatively high superconducting transition temperature of ~15 K and a correspondingly large energy gap. FIB patterning of the TiN films and nanoscale sculpturing of the tip area of the nanoSQUID’s cantilevers are performed using amorphous Al films as sacrificial layers due to their high chemical reactivity to alkalis. A cantilever is realized with a distance between the nanoSQUID and the substrate corner of ~300 nm. The nJJs and nanoSQUID are characterized using Quantum Design measurement systems at 4.2 K. The technology is expected to be of interest for the fabrication of durable nanoSQUID sensors for low temperature magnetic microscopy, as well as for the realization of more complex circuits for superconducting nanobridge electronics. Full article
(This article belongs to the Special Issue Nanofabrication of Superconducting Circuits)
Show Figures

Figure 1

14 pages, 8229 KB  
Article
Improving Energy Harvesting from Bridge Vibration Excited by Moving Vehicles with a Bi-Stable Harvester
by Zhiyong Zhou, Haiwei Zhang, Weiyang Qin, Pei Zhu and Wenfeng Du
Materials 2022, 15(6), 2237; https://doi.org/10.3390/ma15062237 - 17 Mar 2022
Cited by 6 | Viewed by 3536
Abstract
To monitor the health status of the bridge, many sensors are needed to be mounted on it. Converting bridge vibration energy to electrical energy is considered as a potential solution to the problem of providing reliable electric power to these sensors. The objective [...] Read more.
To monitor the health status of the bridge, many sensors are needed to be mounted on it. Converting bridge vibration energy to electrical energy is considered as a potential solution to the problem of providing reliable electric power to these sensors. The objective of this work is to present an operable strategy for improving the electric energy output of a piezoelectric energy harvester installed on a bridge by introducing bi-stable characteristics. A bi-stable harvester is proposed. By adjusting the tip and fixed magnets, different types of potential energy can be generated, and then the harvester can exhibit the linear, mono-stable and bi-stable characteristics. In the bi-stable state, the harvester triggers snap-through motions easily and generates large outputs. The corresponding prototype was fabricated, and the experiment was carried out to validate the advantage of the bi-stable energy harvester. The experiment results show that the bi-stable energy harvester outperforms the classical linear harvester over the whole range of vehicle speed. As the vehicle speed exceeds a critical one, the snap-through motion will happen, which is beneficial to enhancing the electricity output. This conceptual design may provide guidance for promoting the performance of bridge energy harvesting. Full article
(This article belongs to the Topic Electromaterials for Environment & Energy)
Show Figures

Figure 1

9 pages, 17092 KB  
Communication
A Wearable Breath Sensor Based on Fiber-Tip Microcantilever
by Cong Zhao, Dan Liu, Zhihao Cai, Bin Du, Mengqiang Zou, Shuo Tang, Bozhe Li, Cong Xiong, Peng Ji, Lichao Zhang, Yuan Gong, Gaixia Xu, Changrui Liao and Yiping Wang
Biosensors 2022, 12(3), 168; https://doi.org/10.3390/bios12030168 - 7 Mar 2022
Cited by 40 | Viewed by 6547
Abstract
Respiration rate is an essential vital sign that requires monitoring under various conditions, including in strong electromagnetic environments such as in magnetic resonance imaging systems. To provide an electromagnetically-immune breath-sensing system, we propose an all-fiber-optic wearable breath sensor based on a fiber-tip microcantilever. [...] Read more.
Respiration rate is an essential vital sign that requires monitoring under various conditions, including in strong electromagnetic environments such as in magnetic resonance imaging systems. To provide an electromagnetically-immune breath-sensing system, we propose an all-fiber-optic wearable breath sensor based on a fiber-tip microcantilever. The microcantilever was fabricated on a fiber-tip by two-photon polymerization microfabrication based on femtosecond laser, so that a micro Fabry–Pérot (FP) interferometer was formed between the microcantilever and the end-face of the fiber. The cavity length of the micro FP interferometer was reduced as a result of the bending of the microcantilever induced by breath airflow. The signal of breath rate was rebuilt by detecting power variations of the FP interferometer reflected light and applying dynamic thresholds. The breath sensor achieved a high sensitivity of 0.8 nm/(m/s) by detecting the reflection spectrum upon applied flow velocities from 0.53 to 5.31 m/s. This sensor was also shown to have excellent thermal stability as its cross-sensitivity of airflow with respect to the temperature response was only 0.095 (m/s)/°C. When mounted inside a wearable surgical mask, the sensor demonstrated the capability to detect various breath patterns, including normal, fast, random, and deep breaths. We anticipate the proposed wearable breath sensor could be a useful and reliable tool for respiration rate monitoring. Full article
(This article belongs to the Collection Wearable Biosensors for Healthcare Applications)
Show Figures

Figure 1

Back to TopTop