Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (34)

Search Parameters:
Keywords = lateral-torsional buckling

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
26 pages, 5946 KiB  
Article
Flexural Strength of Cold-Formed Steel Unstiffened and Edge-Stiffened Hexagonal Perforated Channel Sections
by G. Beulah Gnana Ananthi, Dinesh Lakshmanan Chandramohan, Dhananjoy Mandal and Asraf Uzzaman
Buildings 2025, 15(15), 2679; https://doi.org/10.3390/buildings15152679 - 29 Jul 2025
Viewed by 205
Abstract
Cold-formed steel (CFS) channel beams are increasingly used as primary structural elements in modern construction due to their lightweight and high-strength characteristics. To accommodate building services, these members often feature perforations—typically circular and unstiffened—produced by punching. Recent studies indicate that adding edge stiffeners, [...] Read more.
Cold-formed steel (CFS) channel beams are increasingly used as primary structural elements in modern construction due to their lightweight and high-strength characteristics. To accommodate building services, these members often feature perforations—typically circular and unstiffened—produced by punching. Recent studies indicate that adding edge stiffeners, particularly around circular web openings, can improve flexural strength. Extending this idea, attention has shifted to hexagonal web perforations; however, limited research exists on the bending performance of hexagonal cold-formed steel channel beams (HCFSBs). This study presents a detailed nonlinear finite element (FE) analysis to evaluate and compare the flexural behaviour of HCFSBs with unstiffened (HUH) and edge-stiffened (HEH) hexagonal openings. The FE models were validated against experimental results and expanded to include a comprehensive parametric study with 810 simulations. Results show that HEH beams achieve, on average, a 10% increase in moment capacity compared to HUH beams. However, when evaluated using current Direct Strength Method (DSM) provisions, moment capacities were underestimated by up to 47%, particularly in cases governed by lateral–torsional or distortional buckling. A reliability analysis confirmed that the proposed design equations yield accurate and dependable strength predictions. Full article
(This article belongs to the Special Issue Cold-Formed Steel Structures)
Show Figures

Figure 1

18 pages, 1933 KiB  
Article
LTBWTB: A Mathematica Software to Evaluate the Lateral-Torsional Buckling Load of Web-Tapered Mono-Symmetric I-Section Beams
by Tolga Yılmaz
Appl. Sci. 2025, 15(13), 7572; https://doi.org/10.3390/app15137572 - 6 Jul 2025
Viewed by 319
Abstract
Web-tapered beams with I-sections, which are aesthetic and structurally efficient, have been widely used in steel structures. Web-tapered I-section beams bent about the strong axis may undergo out-of-plane buckling through lateral deflection and twisting. This primary stability failure mode in slender beams is [...] Read more.
Web-tapered beams with I-sections, which are aesthetic and structurally efficient, have been widely used in steel structures. Web-tapered I-section beams bent about the strong axis may undergo out-of-plane buckling through lateral deflection and twisting. This primary stability failure mode in slender beams is known as lateral-torsional buckling (LTB). Unlike prismatic I-beams, the complex mode shape of web-tapered I-section beams makes it challenging or even impossible to derive a closed-form expression for the LTB load under certain transverse loading conditions. Therefore, the LTB assessment of web-tapered I-section beams is primarily performed using finite element analysis (FEA). However, this method involves multiple steps, requires specialized expertise, and demands significant computational resources, making it impractical in certain cases. This study proposes an analytical approach based on the Ritz method to evaluate the LTB of simply supported web-tapered beams with doubly or mono-symmetric I-sections. The proposed analytical method accounts for web tapering, I-section mono-symmetry, types and positions of transverse loads, and beam slenderness. The method was implemented in Mathematica to allow the rapid evaluation of the LTB capacity of web-tapered I-beams. The study validates the LTB loads computed using the developed Mathematica package against results from shell-based FEA. An excellent agreement was observed between the analytically and numerically calculated LTB loads. Full article
Show Figures

Figure 1

23 pages, 5213 KiB  
Article
Fire Test on Insulated Steel Beams with Fire-Protection Coating and Fiber Cement Board
by Weihua Wang, Tao Zhu, Xian Gao, Jingjie Yang, Xilong Chen and Weiyong Wang
Buildings 2025, 15(12), 2121; https://doi.org/10.3390/buildings15122121 - 18 Jun 2025
Viewed by 305
Abstract
Fire safety design for steel beams is crucial in the construction of steel structures. However, there remains a significant gap in the fire resistance testing of insulated steel beams. This study focuses on full-scale experimental research examining the fire resistance performance of steel [...] Read more.
Fire safety design for steel beams is crucial in the construction of steel structures. However, there remains a significant gap in the fire resistance testing of insulated steel beams. This study focuses on full-scale experimental research examining the fire resistance performance of steel beams with varying fire protection methods, cross-sectional dimensions, and heating curves. During the tests, the furnace temperature, specimen temperature, and deflection at mid-span were measured. The test results indicated that specimens mainly failed in lateral–torsional buckling. Additionally, a markedly non-uniform temperature distribution was observed across the cross-section, and the predictions made by GB 51249-2017 were found to be unsafe. The use of fiber cement board for fire protection may be ineffective, as it tends to become brittle at elevated temperatures, making it susceptible to breakage and detachment when the beams begin to bend. Furthermore, due to potential creep deformation, specimens subjected to longer heating durations exhibited lower critical temperatures compared to those with shorter heating durations. Finally, the design method outlined in BS EN 1993-1-2 and ANSI/AISC 360-22 was evaluated against the test results, indicating an accurate prediction of these methods for specimens with shorter heating durations, but an unconservative prediction for specimens with longer heating durations due to ignorance of creep deformation. Full article
(This article belongs to the Section Building Structures)
Show Figures

Figure 1

21 pages, 6685 KiB  
Article
Lateral-Torsional Buckling Behavior of Low-Carbon H-Shape Bolted Composite Beams
by Kojo Kumah Darkwah, Linfeng Lu, Bingyou Liu, Zhengzhong Huang and Hanlin Hao
Buildings 2025, 15(5), 688; https://doi.org/10.3390/buildings15050688 - 22 Feb 2025
Viewed by 544
Abstract
The construction industry faces increasing pressure to reduce energy consumption and carbon emissions. Promoting sustainable practices, such as using hot-rolled H-shapes and minimizing welding, can address these challenges. This study introduces low-carbon H-shape bolted composite beams (HBCBs) as a sustainable alternative. Experimental and [...] Read more.
The construction industry faces increasing pressure to reduce energy consumption and carbon emissions. Promoting sustainable practices, such as using hot-rolled H-shapes and minimizing welding, can address these challenges. This study introduces low-carbon H-shape bolted composite beams (HBCBs) as a sustainable alternative. Experimental and numerical investigations into the lateral-torsional buckling behavior of HBCBs demonstrated that high-strength bolts significantly enhance structural stability and capacity. A reliable simulation method was developed and validated based on experimental results. The study reveals that bolt spacing exceeding 1/15 of the beam span has negligible effects on load-bearing capacity, and HBCB performance reaches approximately 95% of plug-welded counterparts. Despite this, longitudinal slip reduction remains challenging, warranting further research to optimize performance. Full article
(This article belongs to the Special Issue Advanced Studies on Steel Structures)
Show Figures

Figure 1

25 pages, 7513 KiB  
Article
Lateral–Torsional Buckling of Externally Prestressed I-Section Steel Beams Subjected to Fire
by Abdellah Mahieddine, Noureddine Ziane, Giuseppe Ruta, Rachid Zahi, Mohamed Zidi and Sid Ahmed Meftah
CivilEng 2024, 5(4), 1110-1134; https://doi.org/10.3390/civileng5040054 - 29 Nov 2024
Viewed by 1164
Abstract
We develop a new analytical and numerical approach, based on existing models, to describe the onset of lateral–torsional buckling (LTB) for simply supported thin-walled steel members. The profiles have uniform I cross-sections with variable lengths of the flanges, to describe also H cross-sections, [...] Read more.
We develop a new analytical and numerical approach, based on existing models, to describe the onset of lateral–torsional buckling (LTB) for simply supported thin-walled steel members. The profiles have uniform I cross-sections with variable lengths of the flanges, to describe also H cross-sections, they are prestressed by external tendons, and they are subjected to fire and various loadings. Our approach manages to update the value of the prestressing force, accounting for thermal and loads; the critical multipliers result from an eigenvalue problem obtained applying Galërkin’s approach to a system of nonlinear equilibrium equations. Our results are compared to buckling, steady state, and transient state analyses of a Finite Element Method (FEM) simulation, in which an original expression for an equivalent thermal expansion coefficient for the beam–tendon system that accounts for both mechanical and thermal strains is introduced. Our aim is to find estimates for the critical conditions with no geometric imperfections and accounting for the decay of material properties due to fire, thus providing limit values useful for conservative design. This approach can surpass others in the literature and in the existing technical norms. Full article
(This article belongs to the Special Issue "Stability of Structures", in Memory of Prof. Marcello Pignataro)
Show Figures

Figure 1

22 pages, 20139 KiB  
Article
Investigation on Flexural Behavior of Galvanized Cold-Formed Steel Beams Exposed to Fire with Different Stiffener Configurations
by Varun Sabu Sam, Garry Wegara K Marak, Anand Nammalvar, Diana Andrushia, Beulah Gnana Ananthi Gurupatham and Krishanu Roy
Fire 2024, 7(9), 318; https://doi.org/10.3390/fire7090318 - 13 Sep 2024
Cited by 12 | Viewed by 1515
Abstract
Cold-formed steel (CFS) sections, increasingly favored in the construction industry due to their numerous advantages over hot-rolled steel, have received limited attention in research concerning the flexural behavior of galvanized iron (GI)-based CFS at elevated temperatures. Understanding how these materials and structures behave [...] Read more.
Cold-formed steel (CFS) sections, increasingly favored in the construction industry due to their numerous advantages over hot-rolled steel, have received limited attention in research concerning the flexural behavior of galvanized iron (GI)-based CFS at elevated temperatures. Understanding how these materials and structures behave under elevated temperatures is crucial for fire safety. The authors have performed experimental studies previously on GI-based CFS under elevated temperatures. In that study, CFS sections made of GI of grade E350 of 1.5 m long and 2 mm thickness were used. Built-up beam sections were tested under two-point loading after heating to 60 and 90 min durations and subsequently cooling them down using air and water. This study aims to uncover the influence of different stiffener configurations on the load carrying capacity of sections under elevated temperature parametrically. With the experimental study results from previous studies as a reference, authors used FEM analysis to comprehensively study the behavior of GI-based CFS sections under fire. Vertical, horizontal, and not providing a stiffener were the configurations selected to study the beams parametrically. Parametric analysis confirmed that different stiffener configurations did not alter the predominant failure mode, which remained distortional buckling across all specimens. Beams with vertical stiffeners demonstrated superior performance compared to those with horizontal stiffeners in parametric analysis. Lateral–torsional buckling was observed in the reference specimen, lacking stiffeners due to inadequate restraint at the supports. Full article
Show Figures

Figure 1

29 pages, 11922 KiB  
Article
Using Machine Learning Algorithms to Develop a Predictive Model for Computing the Maximum Deflection of Horizontally Curved Steel I-Beams
by Elvis Ababu, George Markou and Sarah Skorpen
Computation 2024, 12(8), 151; https://doi.org/10.3390/computation12080151 - 24 Jul 2024
Viewed by 1394
Abstract
Horizontally curved steel I-beams exhibit a complicated mechanical response as they experience a combination of bending, shear, and torsion, which varies based on the geometry of the beam at hand. The behaviour of these beams is therefore quite difficult to predict, as they [...] Read more.
Horizontally curved steel I-beams exhibit a complicated mechanical response as they experience a combination of bending, shear, and torsion, which varies based on the geometry of the beam at hand. The behaviour of these beams is therefore quite difficult to predict, as they can fail due to either flexure, shear, torsion, lateral torsional buckling, or a combination of these types of failure. This therefore necessitates the usage of complicated nonlinear analyses in order to accurately model their behaviour. Currently, little guidance is provided by international design standards in consideration of the serviceability limit states of horizontally curved steel I-beams. In this research, an experimentally validated dataset was created and was used to train numerous machine learning (ML) algorithms for predicting the midspan deflection at failure as well as the failure load of numerous horizontally curved steel I-beams. According to the experimental and numerical investigation, the deep artificial neural network model was found to be the most accurate when used to predict the validation dataset, where a mean absolute error of 6.4 mm (16.20%) was observed. This accuracy far surpassed that of Castigliano’s second theorem, where the mean absolute error was found to be equal to 49.84 mm (126%). The deep artificial neural network was also capable of estimating the failure load with a mean absolute error of 30.43 kN (22.42%). This predictive model, which is the first of its kind in the international literature, can be used by professional engineers for the design of curved steel I-beams since it is currently the most accurate model ever developed. Full article
(This article belongs to the Special Issue Computational Methods in Structural Engineering)
Show Figures

Figure 1

26 pages, 5898 KiB  
Article
Evaluation of the Influence of Bolt Fastener Spacing on the Elastic Critical Load from the Lateral-Torsional Buckling Condition of Built-Up Bending Members
by Rafał Piotrowski and Andrzej Szychowski
Materials 2024, 17(14), 3392; https://doi.org/10.3390/ma17143392 - 9 Jul 2024
Viewed by 952
Abstract
In an experimental study of two-branched beams bent transversely about the major stiffness axis, the elastic critical load from the lateral-torsional buckling condition was determined. The tests were conducted on simply supported two-branch beam models with a built-up section consisting of two cold-formed [...] Read more.
In an experimental study of two-branched beams bent transversely about the major stiffness axis, the elastic critical load from the lateral-torsional buckling condition was determined. The tests were conducted on simply supported two-branch beam models with a built-up section consisting of two cold-formed channel members (2C) bolted back-to-back. The bolts were located at the mid-height of the built-up cross-section. Five groups of members differing in longitudinal bolt spacing were examined. The models were gravitationally loaded (using ballast) at the centre of the beam span. This approach eliminated the undesirable effect of the lateral support of the beam, e.g., by the actuator head. The critical load, measured by the concentrated transverse force (Pz,cr), was determined using the modified Southwell method. It has been experimentally shown that, in built-up beams, there is an influence of bolt spacing on the elastic critical load from the lateral-torsional buckling condition. The lowest critical load capacity and the most non-linear behaviour of the built-up member were observed in beams bolted with only three bolts (at the supports and in the middle of the span). However, the experimental results obtained in this study show that increasing the number of bolts above a certain level (in the case of the tested models, it was seven bolts) does not result in a further increase in the critical load, which is a surprising result. The obtained values were 15 to 23% lower than the critical load determined numerically by the finite element method (LTBeamN) for an analogous element with a uniform I-section. Full article
Show Figures

Figure 1

23 pages, 5807 KiB  
Article
Experimental Investigation and Design of Novel Hollow Flange Beams under Bending
by Jingya Xue, Shiliang Ma, Xiaomiao Chen, Qing Wu, Yifan Wang, Yunqing Wang, Muhammad Akbar and Ning Yang
Buildings 2024, 14(5), 1413; https://doi.org/10.3390/buildings14051413 - 14 May 2024
Cited by 2 | Viewed by 1279
Abstract
In this paper, a new type of assembling rivet-fastened rectangular hollow flange beams (ARHFBs) is proposed. The cross-section of the ARHFB consists of two U-shaped and C-shaped components connected by self-locking rivets to form two rectangular hollow flanges. To study the performance and [...] Read more.
In this paper, a new type of assembling rivet-fastened rectangular hollow flange beams (ARHFBs) is proposed. The cross-section of the ARHFB consists of two U-shaped and C-shaped components connected by self-locking rivets to form two rectangular hollow flanges. To study the performance and strength of the ARHFB as a flexural member, eight four-point bending tests and more than 40 simulation studies were carried out. The details, results, and comparison of the four-point bending tests, especially the characteristics of the test bench and the lateral support, are presented in this paper. ARHFB sections with varied rivet spacing, web depth, and flange width were experimentally studied. Additionally, a parametric study of ARHFB was conducted using finite element models verified by test results. The influence of span on the loading capacity of ARHFB was discussed. ARHFB can be used in large-span buildings. A more economical ARHFB component selection method was given. The depth of the flange, the strength of the web, and the thickness of the web are important parameters of ARHFB. The loading capacity obtained from the test was compared with the predicted values of the design formulas in the American Iron and Steel Institute (AISI) and the Chinese design standard for cold-rolled steel (GB50018). The calculation and verification of ARHFB flange buckling and lateral torsional buckling were also considered. It is recommended that GB50018 be used to predict the flexural capacity of ARHFBs. Full article
(This article belongs to the Section Building Structures)
Show Figures

Figure 1

23 pages, 7751 KiB  
Article
Global Buckling Resistance of Cold-Formed Steel Beams with Omega-Shaped Sections
by Rita Peres, José Carvalho, Jean Antonio Emerick, Luís Macedo, José Luiz Rangel Paes and José Miguel Castro
Appl. Sci. 2024, 14(9), 3857; https://doi.org/10.3390/app14093857 - 30 Apr 2024
Cited by 1 | Viewed by 1650
Abstract
The absence of analytical expressions in current codes for evaluating the critical moment for lateral–torsional buckling of cold-formed beams with omega-shaped sections presents a fundamental challenge when assessing their resistance to global buckling. In response to this challenge, a comparative study was conducted [...] Read more.
The absence of analytical expressions in current codes for evaluating the critical moment for lateral–torsional buckling of cold-formed beams with omega-shaped sections presents a fundamental challenge when assessing their resistance to global buckling. In response to this challenge, a comparative study was conducted to explore various approaches for calculating the critical moment. This involved both analytical and numerical analyses, using different methods available in codes and computational tools. The analytical analysis followed the Effective Width Method, employing the expression proposed in ENV 1993-1-1:1992, which is commonly used for evaluating the critical lateral–torsional moment of hot-rolled profiles. Numerical analyses were then performed using the ABAQUS v6.13, GBTUL v2.0, and CUFSM v5.05 software packages. The ABAQUS model, validated with results obtained from an experimental campaign, serves as the reference model. Upon assessing the bending moment resistances according to European, Brazilian, and American standards, consistency was found among these standards. However, it became evident that using the analytical expression proposed for hot-rolled profiles is inadequate for evaluating the critical lateral–torsional moment of CFS omega-shaped profiles. Conversely, the agreement between the ABAQUS, GBTUL, and CUFSM results suggests their utility as reliable tools for estimating the elastic critical lateral–torsional buckling moment. Full article
(This article belongs to the Special Issue Steel Structural Stability in Civil Engineering)
Show Figures

Figure 1

25 pages, 9755 KiB  
Article
Rotational Stiffening Performance of Roof Folded Plates in Torsion Tests and the Stiffening Effect of Roof Folded Plates on the Lateral Buckling of H Beams in Steel Structures
by Yuki Yoshino and Yoshihiro Kimura
Buildings 2024, 14(4), 1158; https://doi.org/10.3390/buildings14041158 - 19 Apr 2024
Cited by 4 | Viewed by 1654
Abstract
Non-structural members, such as roofs and ceilings, become affixed to main beams that are known as structural members. When such main beams experience bending or compressive forces that lead to lateral buckling, non-structural members may act to restrain the resulting lateral buckling deformation. [...] Read more.
Non-structural members, such as roofs and ceilings, become affixed to main beams that are known as structural members. When such main beams experience bending or compressive forces that lead to lateral buckling, non-structural members may act to restrain the resulting lateral buckling deformation. Nevertheless, neither Japanese nor European guidelines advocate for the utilization of non-structural members as lateral buckling stiffeners for beams. Additionally, local buckling ensues near the bolt apertures in the beam–roof folded plate connection due to the torsional deformation induced by the lateral buckling of the H beam, thereby reducing the rotational stiffness of the roof folded plate to a percentage of its ideal stiffness. This paper conducts torsional experiments on roof folded plates, and with various connection methods between these plates and the beams, to comprehend the deformation mechanism of roof folded plates and the relationship between their rotational stiffness and the torsional moment. Then, the relationship between the demand values against restraining the lateral buckling of the main beam and the experimentally determined bearing capacity of the roof folded plate is elucidated. Results indicate the efficacy of utilizing the roof folded plate as a continuous brace. The lateral buckling design capacity of H beams that are continuously stiffened by roof folded plates is elucidated via application of a connection method that ensures joint stiffness between the roof folded plate and the beam while using Japanese and European design codes. Full article
Show Figures

Figure 1

21 pages, 13187 KiB  
Article
An Experimental Study on the Seismic Performance of a Replaceable Steel Link System Acting as a Structural Fuse
by Kyong Min Ro, Min Sook Kim and Young Hak Lee
Appl. Sci. 2024, 14(6), 2358; https://doi.org/10.3390/app14062358 - 11 Mar 2024
Viewed by 1404
Abstract
This study investigated the seismic performance of reinforced concrete columns retrofitted with Replaceable Steel Links (RSLs), focusing on the effects of varying sliding slot lengths and torsional loads. The RSL system, known for its simple construction and effective seismic performance, was analyzed to [...] Read more.
This study investigated the seismic performance of reinforced concrete columns retrofitted with Replaceable Steel Links (RSLs), focusing on the effects of varying sliding slot lengths and torsional loads. The RSL system, known for its simple construction and effective seismic performance, was analyzed to assess the feasibility of substituting damaged steel links post-earthquake, using the system as a structural fuse. The experimental results highlighted the role of sliding slot lengths in delaying the initiation of shear cracks, especially under eccentric lateral loads. The RSL system exhibited notable torsional resistance, showing only a 10% decrease in maximum load capacity, even with a two-fold increase in the eccentric distance. Furthermore, with an increase in sliding slot length, the difference in cumulative energy dissipation attributable to augmented eccentric distances reached approximately 50%, indicating a notable impact of sliding slot length on the system’s ability to resist torsion. Consequently, it is recommended that the length of the sliding slot be based on the specific seismic design objectives when employing the RSL system as a structural fuse. The post-experiment inspection revealed no deformation in the steel plates, and the buckled steel links could be effortlessly replaced by loosening the high-tensile bolts in the slots. These findings demonstrate the RSL system’s efficiency as a structural fuse. Full article
Show Figures

Figure 1

20 pages, 5758 KiB  
Article
Theoretical Study Regarding the General Stability of Upper Chords of Truss Bridges as Beams on Continuous or Discrete Elastic Supports
by Ionuţ-Radu Răcănel
Infrastructures 2024, 9(3), 56; https://doi.org/10.3390/infrastructures9030056 - 10 Mar 2024
Cited by 3 | Viewed by 2655
Abstract
New or in-service truss bridges, with or without upper bracing systems, may display instability phenomena such as general lateral torsional buckling of the upper chord. The buckling of structural elements, particularly in the case of steel bridges, can be associated with the risk [...] Read more.
New or in-service truss bridges, with or without upper bracing systems, may display instability phenomena such as general lateral torsional buckling of the upper chord. The buckling of structural elements, particularly in the case of steel bridges, can be associated with the risk of collapse or temporary/permanent withdrawal from service. Such incidents have occurred in the case of several bridges in different countries: the collapse of the Dee bridge with truss girders in 1847 in Cheshire, England; the collapse of the semi-parabolic truss girder bridge near Ljubičevo over the Morava River in Serbia in 1892; the collapse of the Dysart bridge in Cambria County, Pennsylvania in 2007; the collapse of the Chauras bridge in Uttarakhand, India in 2012; and the collapse of a bridge in Nova Scotia, Canada (2020), and such examples may continue. Buckling poses a significant danger as it often occurs at lower load values compared to those considered during the design phase. Additionally, this phenomenon can manifest suddenly, without prior warning, rendering intervention for its prevention impossible or futile. In contemporary times, most research and design calculation software offer the capability to establish preliminary values for buckling loads, even for highly intricate structures. This is typically achieved through linear eigenvalue buckling analyses, often followed by significantly more complex large displacement nonlinear analyses. However, interpreting the results for complex bridge structures can be challenging, and their accuracy is difficult to ascertain. Consequently, this paper aims to introduce an original method for a more straightforward estimation of the buckling load of the upper chord in steel truss bridges. This method utilizes the theory of beams on discrete elastic supports. The buckling load of the upper chord was determined using both the finite element method and the proposed methodology, yielding highly consistent results. Full article
(This article belongs to the Topic Advances on Structural Engineering, 2nd Volume)
Show Figures

Figure 1

21 pages, 925 KiB  
Article
Numerical Evaluation of Lateral Torsional Buckling of PFRP Channel Beams under Pure Bending
by Elahe Zeinali, Ali Nazari and Hossein Showkati
Sustainability 2024, 16(1), 303; https://doi.org/10.3390/su16010303 - 28 Dec 2023
Cited by 1 | Viewed by 1318
Abstract
The use of pultruded fiber reinforced polymers (PFRPs) in strengthening and sustainable design of bridges and other structures exposed to corrosion and resistance reduction factors is growing rapidly. However, a comprehensive understanding of the structural behavior of these materials under various loading conditions [...] Read more.
The use of pultruded fiber reinforced polymers (PFRPs) in strengthening and sustainable design of bridges and other structures exposed to corrosion and resistance reduction factors is growing rapidly. However, a comprehensive understanding of the structural behavior of these materials under various loading conditions is crucial to unlock their full potential and promote their wider use in diverse structural and industrial applications. Pultrusion profiles can be also used as beams in bridges. One important aspect of the structural behavior of PFRPs is their buckling behavior, particularly in thin-walled open cross sections. Lateral torsional buckling is a probable instability mode for beams with thin-walled open cross sections that are not laterally restrained along their span. Therefore, research on the buckling behavior of PFRP members is essential. In this study, the analytical responses of channel-shaped PFRP beams in bridges under pure bending are calculated using an equation in the Eurocode 3 regulation. The buckling behavior of these beams is then investigated through numerical modeling using the finite element package Abaqus. A total of 75 specimens of PFRP channel profiles with different thicknesses in various spans and lateral restraint conditions are studied for their lateral-torsional buckling behavior. This study uniquely explores the behavior of PFRP beams with lateral restraints, a novel aspect in the field of lateral-torsional buckling research of PFRP beams. The results show that the analytical equation used for these beams needs to be modified to more accurately estimate the buckling loads of FRP beams under the conditions studied in this paper. Full article
Show Figures

Figure 1

3 pages, 1070 KiB  
Proceeding Paper
Comparison of Two Novel Heat-Treated Beam Section and Self-Centering Pinned Connection with Friction Damper Steel Beam–Column Connections
by Arash Akbari Hamed, Mahsa Saeidzadeh and Mohammad Reza Chenaghlou
Eng. Proc. 2023, 53(1), 12; https://doi.org/10.3390/IOCBD2023-15195 - 24 Oct 2023
Cited by 1 | Viewed by 710
Abstract
This study presents a comparative analysis of the structural performance of two innovative steel beam–column connections, namely a self-centering pinned connection with friction damper (SC-PC-FD) and a heat-treated beam section (HBS). The findings indicate that the SC-PC-FD connection exhibits stable, flag-shaped behavior, while [...] Read more.
This study presents a comparative analysis of the structural performance of two innovative steel beam–column connections, namely a self-centering pinned connection with friction damper (SC-PC-FD) and a heat-treated beam section (HBS). The findings indicate that the SC-PC-FD connection exhibits stable, flag-shaped behavior, while the HBS connection can withstand applied loadings up to a rotation of 6% without any occurrence of lateral–torsional buckling. Upon comparison of these connections, it is evident that the SC-PC-FD connection can eliminate residual drifts and provide higher ductility up to a rotation of 7%, while maintaining the main members within the elastic range. Full article
(This article belongs to the Proceedings of The 1st International Online Conference on Buildings)
Show Figures

Figure 1

Back to TopTop