Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (22)

Search Parameters:
Keywords = helical computed tomography

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
17 pages, 6946 KiB  
Article
Multi-Detector Helical Computed Tomography, Transrectal Ultrasonography, and Histology of the Sacroiliac Joint: A Comparative Study in Adult Warmblood Horse Cadavers
by Rebecca A. Mathys, Thomas R. Schmitz, Hans Geyer, Nicole Borel, Monika Hilbe, Stefanie Ohlerth and Andrea S. Bischofberger
Animals 2025, 15(13), 1995; https://doi.org/10.3390/ani15131995 - 7 Jul 2025
Viewed by 294
Abstract
This study described, assessed and correlated ultrasonographic, computed tomographic, and histological findings in the sacroiliac joints of adult Warmblood horse cadavers. In total, 25 joints from 15 horses were examined post-mortem using transrectal ultrasonography and helical computed tomography. Findings on computed tomography were [...] Read more.
This study described, assessed and correlated ultrasonographic, computed tomographic, and histological findings in the sacroiliac joints of adult Warmblood horse cadavers. In total, 25 joints from 15 horses were examined post-mortem using transrectal ultrasonography and helical computed tomography. Findings on computed tomography were graded in the caudal joint third (caudally) and for the entire joint as mild, moderate, or severe. In total, 11 joints from nine horses were evaluated histologically. All joints (100%) showed abnormalities on computed tomography, and 92% (23/25) displayed abnormal ultrasonographic findings. The most common ultrasonographic findings were osteophytes (92%), joint effusion (76%), and sacral/iliac bone modeling (76%). Computed tomography revealed osteophytes (92% caudally, 100% overall), sclerosis (72% caudally, 88% overall), subchondral bone lesions (60% caudally, 88% overall), and enthesophytes (60% caudally, 68% overall). The most severe CT findings occurred caudally (44%), whereas 24% occurred cranially,16% in the mid portion of the SIJ, and 16% were multifocally present in the SIJ Histological analysis showed degenerative changes in the cartilage, subchondral bone, and the joint capsule. Horses with more pronounced imaging abnormalities also showed corresponding histological degeneration. Significant correlations were found between computed tomographic findings caudally and in the entire joint (rs = 0.915, p < 0.001, n = 25), and between imaging and histological findings (computed tomography: rs = 0.731, p = 0.011, n = 11; ultrasonography: rs = 0.67, p = 0.024, n = 11). Non-significant correlations were observed between mean ultrasonographic and computed-tomographic grades (rs = 0.35, p = 0.087, n = 25). Findings suggest these structural changes may reflect adaptation to joint loading. Transrectal ultrasonography appears suitable as a first-line diagnostic tool. However, future studies are essential to compare the diagnostic imaging findings of SIJs in asymptomatic and symptomatic horses to elucidate their clinical relevance. Full article
(This article belongs to the Section Equids)
Show Figures

Figure 1

18 pages, 3540 KiB  
Article
A Retrospective Analysis of the First Clinical 5DCT Workflow
by Michael Lauria, Minji Kim, Dylan O’Connell, Yi Lao, Claudia R. Miller, Louise Naumann, Peter Boyle, Ann Raldow, Alan Lee, Ricky R. Savjani, Drew Moghanaki and Daniel A. Low
Cancers 2025, 17(3), 531; https://doi.org/10.3390/cancers17030531 - 5 Feb 2025
Viewed by 880
Abstract
Background/Objectives: 5DCT was first proposed in 2005 as a motion-compensated CT simulation approach for radiotherapy treatment planning to avoid sorting artifacts that arise in 4DCT when patients breathe irregularly. Since March 2019, 5DCT has been clinically implemented for routine use at our institution [...] Read more.
Background/Objectives: 5DCT was first proposed in 2005 as a motion-compensated CT simulation approach for radiotherapy treatment planning to avoid sorting artifacts that arise in 4DCT when patients breathe irregularly. Since March 2019, 5DCT has been clinically implemented for routine use at our institution to leverage this technological advantage. The clinical workflow includes a quality assurance report that describes the output of primary workflow steps. This study reports on the challenges and quality of the clinical 5DCT workflow using these quality assurance reports. Methods: We evaluated all thoracic 5DCT simulation datasets consecutively acquired at our institution between March 2019 and December 2022 for thoracic radiotherapy treatment planning. The 5DCT datasets utilized motion models constructed from 25 fast-helical free-breathing computed tomography (FHFBCTs) with simultaneous respiratory bellows signal monitoring to reconstruct individual, user-specified breathing-phase images (termed 5DCT phase images) for internal target volume contouring. Each 5DCT dataset was accompanied by a structured quality assurance report composed of qualitative and quantitative measures of the breathing pattern, image quality, DIR quality, model fitting accuracy, and a validation process by which the original FHFBCT scans were regenerated with the 5DCT model. Measures of breathing irregularity, image quality, and DIR quality were retrospectively categorized on a grading scale from 1 (regular breathing and accurate registration/modeling) to 4 (irregular breathing and inaccurate registration/modeling). The validation process was graded according to the same scale, and this grade was termed the suitability-for-treatment-planning (STP) grade. We correlated the graded variables to the STP grade. In addition to the quality assurance reports, we reviewed the contour sessions to determine how often 5DCT phase images were used for treatment planning and delivery. Results: There were 169 5DCT simulation datasets available from 156 patients for analysis. The STP was moderately correlated with breathing irregularity, image quality, and DIR quality (Spearman coefficients: 0.26, 0.30, and 0.50, respectively). Multiple linear regression analysis demonstrated that STP was correlated with regular breathing patterns (p = 0.008), image quality (p < 0.001), and better DIR quality (p < 0.001). 5DCT datasets were used for treatment planning in 82% of cases, while in 12% of cases, a backup image process was used. In total, 6% of image datasets were not used for treatment planning due to factors unrelated to the 5DCT workflow quality. Conclusions: The strongest association with STP was with DIR quality grades, as indicated by both Spearman and multiple linear regression analysis, implying that improvements to DIR accuracy and evaluation may be the best route for further improvement to 5DCT. The high rate of 5DCT phase image use for treatment planning showed that the workflow was reliable, and this has encouraged us to continue to develop and improve the workflow steps. Full article
Show Figures

Figure 1

15 pages, 2572 KiB  
Article
Synthetic Amphipathic Helical Peptide L-37pA Ameliorates the Development of Acute Respiratory Distress Syndrome (ARDS) and ARDS-Induced Pulmonary Fibrosis in Mice
by Aleksandr S. Chernov, Georgii B. Telegin, Alexey N. Minakov, Vitaly A. Kazakov, Maksim V. Rodionov, Viktor A. Palikov, Anna A. Kudriaeva and Alexey A. Belogurov
Int. J. Mol. Sci. 2024, 25(15), 8384; https://doi.org/10.3390/ijms25158384 - 1 Aug 2024
Viewed by 1277
Abstract
In this study, we evaluated the ability of the synthetic amphipathic helical peptide (SAHP), L-37pA, which mediates pathogen recognition and innate immune responses, to treat acute respiratory distress syndrome (ARDS) accompanied by diffuse alveolar damage (DAD) and chronic pulmonary fibrosis (PF). For the [...] Read more.
In this study, we evaluated the ability of the synthetic amphipathic helical peptide (SAHP), L-37pA, which mediates pathogen recognition and innate immune responses, to treat acute respiratory distress syndrome (ARDS) accompanied by diffuse alveolar damage (DAD) and chronic pulmonary fibrosis (PF). For the modeling of ARDS/DAD, male ICR mice were used. Intrabronchial instillation (IB) of 200 µL of inflammatory agents was performed by an intravenous catheter 20 G into the left lung lobe only, leaving the right lobe unaffected. Intravenous injections (IVs) of L-37pA, dexamethasone (DEX) and physiological saline (saline) were used as therapies for ARDS/DAD. L37pA inhibited the circulating levels of inflammatory cytokines, such as IL-8, TNFα, IL1α, IL4, IL5, IL6, IL9 and IL10, by 75–95%. In all cases, the computed tomography (CT) data indicate that L-37pA reduced lung density faster to −335 ± 23 Hounsfield units (HU) on day 7 than with DEX and saline, to −105 ± 29 HU and −23 ± 11 HU, respectively. The results of functional tests showed that L-37pA treatment 6 h after ARDS/DAD initiation resulted in a more rapid improvement in the physiological respiratory lung by 30–45% functions compared with the comparison drugs. Our data suggest that synthetic amphipathic helical peptide L-37pA blocked a cytokine storm, inhibited acute and chronic pulmonary inflammation, prevented fibrosis development and improved physiological respiratory lung function in the ARDS/DAD mouse model. We concluded that a therapeutic strategy using SAHPs targeting SR-B receptors is a potential novel effective treatment for inflammation-induced ARDS, DAD and lung fibrosis of various etiologies. Full article
(This article belongs to the Section Molecular Pathology, Diagnostics, and Therapeutics)
Show Figures

Figure 1

13 pages, 1540 KiB  
Article
ADAMTS-13: A Prognostic Biomarker for Portal Vein Thrombosis in Japanese Patients with Liver Cirrhosis
by Junya Suzuki, Tadashi Namisaki, Hiroaki Takya, Kosuke Kaji, Norihisa Nishimura, Akihiko Shibamoto, Shohei Asada, Takahiro Kubo, Satoshi Iwai, Fumimasa Tomooka, Soichi Takeda, Aritoshi Koizumi, Misako Tanaka, Takuya Matsuda, Takashi Inoue, Yuki Fujimoto, Yuki Tsuji, Yukihisa Fujinaga, Shinya Sato, Koh Kitagawa, Hideto Kawaratani, Takemi Akahane, Akira Mitoro, Masanori Matsumoto, Kiyoshi Asada and Hitoshi Yoshijiadd Show full author list remove Hide full author list
Int. J. Mol. Sci. 2024, 25(5), 2678; https://doi.org/10.3390/ijms25052678 - 26 Feb 2024
Cited by 2 | Viewed by 2003
Abstract
Portal vein thrombosis (PVT), one of the most prevalent hepatic vascular conditions in patients with liver cirrhosis (LC), is associated with high mortality rates. An imbalance between a disintegrin-like metalloproteinase with thrombospondin type-1 motifs 13 (ADAMTS-13) enzyme and von Willebrand factor (VWF) is [...] Read more.
Portal vein thrombosis (PVT), one of the most prevalent hepatic vascular conditions in patients with liver cirrhosis (LC), is associated with high mortality rates. An imbalance between a disintegrin-like metalloproteinase with thrombospondin type-1 motifs 13 (ADAMTS-13) enzyme and von Willebrand factor (VWF) is responsible for hypercoagulability, including spontaneous thrombus formation in blood vessels. Herein, we aimed to identify potential prognostic and diagnostic biomarkers in Japanese patients with LC and PVT. In total, 345 patients were divided into two groups: 40 patients who developed PVT (PVT group) and 305 who did not develop PVT (NPVT group). Among the 345 patients with LC, 81% (279/345) were deemed ineligible due to the presence of preventive comorbidities, active or recent malignancies, and organ dysfunction. The remaining 66 patients were divided into two groups: the PVT group (n = 33) and the NPVT group (n = 33). Plasma ADAMTS-13 activity (ADAMTS-13:AC) and the vWF antigen (VWF:Ag) were measured using enzyme-linked immunosorbent assays. Contrast-enhanced, three-dimensional helical computed tomography (CT) was used to detect and characterize PVT. ADAMTS-13:AC was significantly lower in the PVT group than in the NPVT group. No significant differences in plasma vWF:Ag or liver stiffness were observed between the two groups. ADAMTS-13:AC of <18.8 was an independent risk factor for PVT on multivariate analyses (odds ratio: 1.67, 95% confidence interval: 1.21–3.00, p < 0.002). The receiver operating characteristic analysis of ADAMTS-13:AC revealed an area under the curve of 0.913 in PVT detection. Patients with PVT having ADAMTS-13:AC ≥18.8 (n = 17) had higher albumin levels and better prognoses than those with ADAMTS-13:AC <18.8 (n = 16). No significant correlations of ADAMTS-13:AC levels with either fibrin degradation product or D-dimer levels were observed. ADAMTS-13:AC levels could be potential diagnostic and prognostic biomarkers for PVT in Japanese patients with LC. Full article
(This article belongs to the Special Issue Chronic Liver Disease and Hepatocellular Carcinoma)
Show Figures

Figure 1

18 pages, 2410 KiB  
Article
The Smokers Health Multiple ACtions (SMAC-1) Trial: Study Design and Results of the Baseline Round
by Alberto Antonicelli, Piergiorgio Muriana, Giovanni Favaro, Giuseppe Mangiameli, Ezio Lanza, Manuel Profili, Fabrizio Bianchi, Emanuela Fina, Giuseppe Ferrante, Simone Ghislandi, Daniela Pistillo, Giovanna Finocchiaro, Gianluigi Condorelli, Rosalba Lembo, Pierluigi Novellis, Elisa Dieci, Simona De Santis and Giulia Veronesi
Cancers 2024, 16(2), 417; https://doi.org/10.3390/cancers16020417 - 18 Jan 2024
Viewed by 2883
Abstract
Background: Lung cancer screening with low-dose helical computed tomography (LDCT) reduces mortality in high-risk subjects. Cigarette smoking is linked to up to 90% of lung cancer deaths. Even more so, it is a key risk factor for many other cancers and cardiovascular and [...] Read more.
Background: Lung cancer screening with low-dose helical computed tomography (LDCT) reduces mortality in high-risk subjects. Cigarette smoking is linked to up to 90% of lung cancer deaths. Even more so, it is a key risk factor for many other cancers and cardiovascular and pulmonary diseases. The Smokers health Multiple ACtions (SMAC-1) trial aimed to demonstrate the feasibility and effectiveness of an integrated program based on the early detection of smoking-related thoraco-cardiovascular diseases in high-risk subjects, combined with primary prevention. A new multi-component screening design was utilized to strengthen the framework on conventional lung cancer screening programs. We report here the study design and the results from our baseline round, focusing on oncological findings. Methods: High-risk subjects were defined as being >55 years of age and active smokers or formers who had quit within 15 years (>30 pack/y). A PLCOm2012 threshold >2% was chosen. Subject outreach was streamlined through media campaign and general practitioners’ engagement. Eligible subjects, upon written informed consent, underwent a psychology consultation, blood sample collection, self-evaluation questionnaire, spirometry, and LDCT scan. Blood samples were analyzed for pentraxin-3 protein levels, interleukins, microRNA, and circulating tumor cells. Cardiovascular risk assessment and coronary artery calcium (CAC) scoring were performed. Direct and indirect costs were analyzed focusing on the incremental cost-effectiveness ratio per quality-adjusted life years gained in different scenarios. Personalized screening time-intervals were determined using the “Maisonneuve risk re-calculation model”, and a threshold <0.6% was chosen for the biennial round. Results: In total, 3228 subjects were willing to be enrolled. Out of 1654 eligible subjects, 1112 participated. The mean age was 64 years (M/F 62/38%), with a mean PLCOm2012 of 5.6%. Former and active smokers represented 23% and 77% of the subjects, respectively. At least one nodule was identified in 348 subjects. LDCTs showed no clinically significant findings in 762 subjects (69%); thus, they were referred for annual/biennial LDCTs based on the Maisonneuve risk (mean value = 0.44%). Lung nodule active surveillance was indicated for 122 subjects (11%). Forty-four subjects with baseline suspicious nodules underwent a PET-FDG and twenty-seven a CT-guided lung biopsy. Finally, a total of 32 cancers were diagnosed, of which 30 were lung cancers (2.7%) and 2 were extrapulmonary cancers (malignant pleural mesothelioma and thymoma). Finally, 25 subjects underwent lung surgery (2.25%). Importantly, there were zero false positives and two false negatives with CT-guided biopsy, of which the patients were operated on with no stage shift. The final pathology included lung adenocarcinomas (69%), squamous cell carcinomas (10%), and others (21%). Pathological staging showed 14 stage I (47%) and 16 stage II-IV (53%) cancers. Conclusions: LDCTs continue to confirm their efficacy in safely detecting early-stage lung cancer in high-risk subjects, with a negligible risk of false-positive results. Re-calculating the risk of developing lung cancer after baseline LDCTs with the Maisonneuve model allows us to optimize time intervals to subsequent screening. The Smokers health Multiple ACtions (SMAC-1) trial offers solid support for policy assessments by policymakers. We trust that this will help in developing guidelines for the large-scale implementation of lung cancer screening, paving the way for better outcomes for lung cancer patients. Full article
(This article belongs to the Special Issue Diagnosis and Innovative Treatment of Localized Lung Cancer)
Show Figures

Figure 1

15 pages, 3531 KiB  
Article
Patient Dose Estimation in Computed Tomography-Guided Biopsy Procedures
by Evangelia Siomou, Dimitrios K. Filippiadis, Efstathios P. Efstathopoulos, Ioannis Antonakos and George S. Panayiotakis
J. Imaging 2023, 9(12), 267; https://doi.org/10.3390/jimaging9120267 - 30 Nov 2023
Cited by 3 | Viewed by 3917
Abstract
This study establishes typical Diagnostic Reference Levels (DRL) values and assesses patient doses in computed tomography (CT)-guided biopsy procedures. The Effective Dose (ED), Entrance Skin Dose (ESD), and Size-Specific Dose Estimate (SSDE) were calculated using the relevant literature-derived conversion factors. A retrospective analysis [...] Read more.
This study establishes typical Diagnostic Reference Levels (DRL) values and assesses patient doses in computed tomography (CT)-guided biopsy procedures. The Effective Dose (ED), Entrance Skin Dose (ESD), and Size-Specific Dose Estimate (SSDE) were calculated using the relevant literature-derived conversion factors. A retrospective analysis of 226 CT-guided biopsies across five categories (Iliac bone, liver, lung, mediastinum, and para-aortic lymph nodes) was conducted. Typical DRL values were computed as median distributions, following guidelines from the International Commission on Radiological Protection (ICRP) Publication 135. DRLs for helical mode CT acquisitions were set at 9.7 mGy for Iliac bone, 8.9 mGy for liver, 8.8 mGy for lung, 7.9 mGy for mediastinal mass, and 9 mGy for para-aortic lymph nodes biopsies. In contrast, DRLs for biopsy acquisitions were 7.3 mGy, 7.7 mGy, 5.6 mGy, 5.6 mGy, and 7.4 mGy, respectively. Median SSDE values varied from 7.6 mGy to 10 mGy for biopsy acquisitions and from 11.3 mGy to 12.6 mGy for helical scans. Median ED values ranged from 1.6 mSv to 5.7 mSv for biopsy scans and from 3.9 mSv to 9.3 mSv for helical scans. The study highlights the significance of using DRLs for optimizing CT-guided biopsy procedures, revealing notable variations in radiation exposure between helical scans covering entire anatomical regions and localized biopsy acquisitions. Full article
(This article belongs to the Section Medical Imaging)
Show Figures

Figure 1

15 pages, 10190 KiB  
Article
Machine Learning-Based Segmentation of the Thoracic Aorta with Congenital Valve Disease Using MRI
by Elias Sundström and Marco Laudato
Bioengineering 2023, 10(10), 1216; https://doi.org/10.3390/bioengineering10101216 - 18 Oct 2023
Cited by 7 | Viewed by 3068
Abstract
Subjects with bicuspid aortic valves (BAV) are at risk of developing valve dysfunction and need regular clinical imaging surveillance. Management of BAV involves manual and time-consuming segmentation of the aorta for assessing left ventricular function, jet velocity, gradient, shear stress, and valve area [...] Read more.
Subjects with bicuspid aortic valves (BAV) are at risk of developing valve dysfunction and need regular clinical imaging surveillance. Management of BAV involves manual and time-consuming segmentation of the aorta for assessing left ventricular function, jet velocity, gradient, shear stress, and valve area with aortic valve stenosis. This paper aims to employ machine learning-based (ML) segmentation as a potential for improved BAV assessment and reducing manual bias. The focus is on quantifying the relationship between valve morphology and vortical structures, and analyzing how valve morphology influences the aorta’s susceptibility to shear stress that may lead to valve incompetence. The ML-based segmentation that is employed is trained on whole-body Computed Tomography (CT). Magnetic Resonance Imaging (MRI) is acquired from six subjects, three with tricuspid aortic valves (TAV) and three functionally BAV, with right–left leaflet fusion. These are used for segmentation of the cardiovascular system and delineation of four-dimensional phase-contrast magnetic resonance imaging (4D-PCMRI) for quantification of vortical structures and wall shear stress. The ML-based segmentation model exhibits a high Dice score (0.86) for the heart organ, indicating a robust segmentation. However, the Dice score for the thoracic aorta is comparatively poor (0.72). It is found that wall shear stress is predominantly symmetric in TAVs. BAVs exhibit highly asymmetric wall shear stress, with the region opposite the fused coronary leaflets experiencing elevated tangential wall shear stress. This is due to the higher tangential velocity explained by helical flow, proximally of the sinutubal junction of the ascending aorta. ML-based segmentation not only reduces the runtime of assessing the hemodynamic effectiveness, but also identifies the significance of the tangential wall shear stress in addition to the axial wall shear stress that may lead to the progression of valve incompetence in BAVs, which could guide potential adjustments in surgical interventions. Full article
Show Figures

Graphical abstract

12 pages, 3835 KiB  
Article
Optimized Conformal Total Body Irradiation with VMAT Using a Linear-Accelerator-Based Radiosurgery Treatment System in Comparison to the Golden Standard Helical TomoTherapy
by Mümtaz Köksal, Oğuzhan Özkan, Tobias Holderried, Annkristin Heine, Peter Brossart, Ahmed Gawish, Davide Scafa, Gustavo R. Sarria, Christina Leitzen, Leonard C. Schmeel and Thomas Müdder
Cancers 2023, 15(17), 4220; https://doi.org/10.3390/cancers15174220 - 23 Aug 2023
Cited by 5 | Viewed by 2267
Abstract
Modern irradiation techniques for optimized conformal TBI can be realized by Helical Tomotherapy (HT) or Volumetric Modulated Arc Therapy (VMAT), depending on the availability of suitable specialized equipment. In this dosimetric planning study, we compared both modalities and addressed the question of whether [...] Read more.
Modern irradiation techniques for optimized conformal TBI can be realized by Helical Tomotherapy (HT) or Volumetric Modulated Arc Therapy (VMAT), depending on the availability of suitable specialized equipment. In this dosimetric planning study, we compared both modalities and addressed the question of whether VMAT with small field sizes is also suitable as a backup in case of HT equipment malfunctions. For this purpose, we retrospectively used planning computed tomography (CT) data from 10 patients treated with HT with a total dose of 8 Gy (n = 5) or 12 Gy (n = 5) for treatment planning for VMAT with a small field size (36 × 22 cm). The target volume coverage, dose homogeneity at target volume, and dose reduction in organs at risk (OAR) (lungs, kidneys, lenses) were analyzed and compared. One patient was irradiated with both modalities due to a device failure of the HT equipment during the study, which facilitated a comparison in a real clinical setting. The findings indicate that in addition to a higher mean dose to the lenses in the 12 Gy group for VMAT and a better dose homogeneity in the target volume for HT, comparably good and adequate target dose coverage and dose reduction in the other OAR could be achieved for both modalities, with significantly longer treatment times for VMAT. In conclusion, after appropriate optimization of the treatment times, VMAT using linear accelerator radiosurgery technology can be used both as a backup in addition to HT and in clinical routines to perform optimized conformal TBI. Full article
(This article belongs to the Special Issue New Approaches to Hematologic Malignancies Radiation Therapy)
Show Figures

Figure 1

12 pages, 2915 KiB  
Article
Influence of Pitch on Surface Dose Distribution and Image Noise of Computed Tomography Scans
by Kenji Yamada, Yoshiki Kawata, Masafumi Amano, Hidenobu Suzuki, Masahide Tominaga, Motoharu Sasaki, Hikaru Nishiyama, Masafumi Harada and Noboru Niki
Sensors 2023, 23(7), 3472; https://doi.org/10.3390/s23073472 - 26 Mar 2023
Cited by 1 | Viewed by 2343
Abstract
This study evaluated the effect of pitch on 256-slice helical computed tomography (CT) scans. Cylindrical water phantoms (CWP) were measured using axial and helical scans with various pitch values. The surface dose distributions of CWP were measured, and reconstructed images were obtained using [...] Read more.
This study evaluated the effect of pitch on 256-slice helical computed tomography (CT) scans. Cylindrical water phantoms (CWP) were measured using axial and helical scans with various pitch values. The surface dose distributions of CWP were measured, and reconstructed images were obtained using filtered back-projection (FBP) and iterative model reconstruction (IMR). The image noise in each reconstructed image was decomposed into a baseline component and another component that varied along the z-axis. The baseline component of the image noise was highest at the center of the reconstructed image and decreased toward the edges. The normalized 2D power spectra for each pitch were almost identically distributed. Furthermore, the ratios of the 2D power spectra for IMR and FBP at different pitch values were obtained. The magnitudes of the components varying along the z-axis were smallest at the center of the reconstructed image and increased toward the edge. The ratios of the 3D power spectra on the fx axis for IMR and FBP at different pitch values were obtained. The results showed that the effect of the pitch was related to the component that varied along the z-axis. Furthermore, the pitch had a smaller effect on IMR than on FBP. Full article
(This article belongs to the Section Sensing and Imaging)
Show Figures

Figure 1

10 pages, 1709 KiB  
Article
Three-Dimensional Volumetric Analysis of Frontal Ethmoidal Cells and Evaluation of Influential Factors: A Helical Computed Tomography Study
by Ana Lúcia Franco Ricardo, Celso Massahiro Ogawa, João Pedro Perez Gomes, Catharina Simioni De Rosa, Sérgio Lúcio Pereira de Castro Lopes, Paulo Henrique Braz-Silva, Kaan Orhan and Andre Luiz Ferreira Costa
Tomography 2022, 8(6), 2796-2805; https://doi.org/10.3390/tomography8060233 - 24 Nov 2022
Cited by 2 | Viewed by 2573
Abstract
In the present study, we aimed to assess frontal ethmoidal cells by using segmentation 3D software to establish a possible correlation between volume variation and both gender and age, as well as a relationship with Keros classification. Helical computed tomography images were obtained [...] Read more.
In the present study, we aimed to assess frontal ethmoidal cells by using segmentation 3D software to establish a possible correlation between volume variation and both gender and age, as well as a relationship with Keros classification. Helical computed tomography images were obtained from 71 patients for analysis, in which the agger nasi cell, supra agger cell, supra agger frontal cell, supra bulla frontal cell, supraorbital ethmoidal cell, supra bulla cell, and frontal septal cell were identified and segmented to obtain their volume. Significant differences in volume were found for age and gender regarding agger nasi cells (p-value = 0.017), supra agger cells (p-value < 0.001), and frontal septal cells (p-value = 0.049). In the frontal septal cells, an increase of one year in age reduced the volume by 0.309, on average. According to Keros classification, the mean volumes were 10.07 and 25.64, respectively, for types II and III, both being greater than that of type I. Extracting volumetric data by using segmentation software in agger nasi cells, supra agger cells, and frontal septal cells may be useful for obtaining additional information related to age, in addition to possibly contributing to elucidating the anatomical variations in the region and an identification forensic tool. Full article
(This article belongs to the Topic Human Anatomy and Pathophysiology, 2nd Volume)
Show Figures

Figure 1

8 pages, 3461 KiB  
Article
A Novel Magnetic Resonance Imaging-Compatible Titanium Alloy Wire-Reinforced Endotracheal Tube
by Bikei Ryu, Yoshikazu Okada, Nobuko Fujita and Yasuko Nagasaka
Materials 2022, 15(16), 5632; https://doi.org/10.3390/ma15165632 - 16 Aug 2022
Cited by 2 | Viewed by 2761
Abstract
Reinforced endotracheal tubes (ET) are advantageous in preventing tube obstruction and kinking by procedural compression during neurosurgeries. However, the standard reinforced ET contains an embedded stainless steel (SS) helical wire, which produces artifacts and heat during magnetic resonance imaging (MRI). Therefore, MRI is [...] Read more.
Reinforced endotracheal tubes (ET) are advantageous in preventing tube obstruction and kinking by procedural compression during neurosurgeries. However, the standard reinforced ET contains an embedded stainless steel (SS) helical wire, which produces artifacts and heat during magnetic resonance imaging (MRI). Therefore, MRI is not indicated in the presence of a reinforced ET containing SS. To overcome this challenge, we developed an MRI-compatible titanium (Ti) reinforced ET. A newly developed Ti alloy helical wire was inserted in a reinforced ET. Here, we report our first clinical experience with six patients who underwent neurosurgery intubated with this Ti-alloy-reinforced ET. The Ti-alloy-reinforced ET was used in six patients requiring reinforced ET intubation. It was clearly delineated on radiography, and metal artifacts were small on computed tomography. Patients intubated with the Ti-alloy-reinforced ET could safely undergo MRI under sedation. MR images without remarkable susceptibility artifacts were obtained without noted adverse effects. We invented a novel Ti-alloy-reinforced ET. This device allows clinical use during MRI because it is less susceptible to artifacts in high magnetic fields. Full article
Show Figures

Figure 1

18 pages, 5877 KiB  
Article
3D-Printed Double-Helical Biodegradable Iron Suture Anchor: A Rabbit Rotator Cuff Tear Model
by Wen-Chih Liu, Chih-Hau Chang, Chung-Hwan Chen, Chun-Kuan Lu, Chun-Hsien Ma, Shin-I Huang, Wei-Lun Fan, Hsin-Hsin Shen, Pei-I Tsai, Kuo-Yi Yang and Yin-Chih Fu
Materials 2022, 15(8), 2801; https://doi.org/10.3390/ma15082801 - 11 Apr 2022
Cited by 8 | Viewed by 4423 | Correction
Abstract
Suture anchors are extensively used in rotator cuff tear surgery. With the advancement of three-dimensional printing technology, biodegradable metal has been developed for orthopedic applications. This study adopted three-dimensional-printed biodegradable Fe suture anchors with double-helical threads and commercialized non-vented screw-type Ti suture anchors [...] Read more.
Suture anchors are extensively used in rotator cuff tear surgery. With the advancement of three-dimensional printing technology, biodegradable metal has been developed for orthopedic applications. This study adopted three-dimensional-printed biodegradable Fe suture anchors with double-helical threads and commercialized non-vented screw-type Ti suture anchors with a tapered tip in the experimental and control groups, respectively. The in vitro study showed that the Fe and Ti suture anchors exhibited a similar ultimate failure load in 20-pound-per-cubic-foot polyurethane foam blocks and rabbit bone. In static immersion tests, the corrosion rate of Fe suture anchors was 0.049 ± 0.002 mm/year. The in vivo study was performed on New Zealand white rabbits and SAs were employed to reattach the ruptured supraspinatus tendon. The in vivo ultimate failure load of the Fe suture anchors was superior to that of the Ti suture anchors at 6 weeks. Micro-computed tomography showed that the bone volume fraction and bone surface density in the Fe suture anchors group 2 and 6 weeks after surgery were superior, and the histology confirmed that the increased bone volume around the anchor was attributable to mineralized osteocytes. The three-dimensional-printed Fe suture anchors outperformed the currently used Ti suture anchors. Full article
(This article belongs to the Collection 3D Printing in Medicine and Biomedical Engineering)
Show Figures

Figure 1

10 pages, 5601 KiB  
Article
Influence of Different Arm Positions in the Localizer Radiograph(s) on Patient Dose during Exposure-Controlled CT Examinations of the Neck to Pelvis
by Tony M. Svahn, Lovre Peric and Jennifer C. Ast
Tomography 2021, 7(3), 313-322; https://doi.org/10.3390/tomography7030028 - 29 Jul 2021
Cited by 4 | Viewed by 4145
Abstract
Our aim was to examine the impact of different arm positions during imaging of the localizer radiograph(s) on effective dose for exposure-controlled computed tomography (CT) (Siemens/Canon) scans of the neck to pelvis. An anthropomorphic whole-body phantom was scanned from the neck to pelvis [...] Read more.
Our aim was to examine the impact of different arm positions during imaging of the localizer radiograph(s) on effective dose for exposure-controlled computed tomography (CT) (Siemens/Canon) scans of the neck to pelvis. An anthropomorphic whole-body phantom was scanned from the neck to pelvis with the arms positioned in three different ways during the acquisition of the localizer radiograph: (i) above the head, (ii) alongside the trunk, and (iii) along the trunk with the hands placed on the abdomen. In accordance with clinical routines, the arms were not included in the subsequent helical scans. Effective doses were computed to a standard-sized patient (male/female) using a dedicated system-specific Monte Carlo-based software. Effective doses for the Canon CT scanner for the different alternatives (male/female) were (a) 5.3/6.62 mSv, (b) 5.62/7.15 mSv and (c) 5.92/7.44 mSv. For the Siemens CT scanner, effective doses were (a) 4.47/5.59 mSv, (b) 5.4/6.69 mSv and (c) 5.7/6.99 mSv. Arms placed above the head during localizer radiograph imaging in the current CT procedures substantially reduced the total effective dose to the patient. Full article
Show Figures

Figure 1

13 pages, 1809 KiB  
Article
Impact of Morphotype on Image Quality and Diagnostic Performance of Ultra-Low-Dose Chest CT
by Anne-Claire Ortlieb, Aissam Labani, François Severac, Mi-Young Jeung, Catherine Roy and Mickaël Ohana
J. Clin. Med. 2021, 10(15), 3284; https://doi.org/10.3390/jcm10153284 - 26 Jul 2021
Cited by 2 | Viewed by 2664
Abstract
Objectives: The image quality of an Ultra-Low-Dose (ULD) chest CT depends on the patient’s morphotype. We hypothesize that there is a threshold beyond which the diagnostic performance of a ULD chest CT is too degraded. This work assesses the influence of morphotype (Body [...] Read more.
Objectives: The image quality of an Ultra-Low-Dose (ULD) chest CT depends on the patient’s morphotype. We hypothesize that there is a threshold beyond which the diagnostic performance of a ULD chest CT is too degraded. This work assesses the influence of morphotype (Body Mass Index BMI, Maximum Transverse Chest Diameter MTCD and gender) on image quality and the diagnostic performance of a ULD chest CT. Methods: A total of 170 patients from three prior prospective monocentric studies were retrospectively included. Renewal of consent was waived by our IRB. All the patients underwent two consecutive unenhanced chest CT acquisitions with a full dose (120 kV, automated tube current modulation) and a ULD (135 kV, fixed tube current at 10 mA). Image noise, subjective image quality and diagnostic performance for nine predefined lung parenchyma lesions were assessed by two independent readers, and correlations with the patient’s morphotype were sought. Results: The mean BMI was 26.6 ± 5.3; 20.6% of patients had a BMI > 30. There was a statistically significant negative correlation of the BMI with the image quality (ρ = −0.32; IC95% = (−0.468; −0.18)). The per-patient diagnostic performance of ULD was sensitivity, 77%; specificity, 99%; PPV, 94% and NPV, 65%. There was no statistically significant influence of the BMI, the MTCD nor the gender on the per-patient and per-lesion diagnostic performance of a ULD chest CT, apart from a significant negative correlation for the detection of emphysema. Conclusions: Despite a negative correlation between the BMI and the image quality of a ULD chest CT, we did not find a correlation between the BMI and the diagnostic performance of the examination, suggesting a possible use of the ULD protocol in obese patients. Full article
Show Figures

Figure 1

12 pages, 17075 KiB  
Article
Cranial Structure of Varanus komodoensis as Revealed by Computed-Tomographic Imaging
by Sara Pérez, Mario Encinoso, Juan Alberto Corbera, Manuel Morales, Alberto Arencibia, Eligia González-Rodríguez, Soraya Déniz, Carlos Melián, Alejandro Suárez-Bonnet and José Raduan Jaber
Animals 2021, 11(4), 1078; https://doi.org/10.3390/ani11041078 - 9 Apr 2021
Cited by 4 | Viewed by 4086
Abstract
This study aimed to describe the anatomic features of the normal head of the Komodo dragon (Varanus komodoensis) identified by computed tomography. CT images were obtained in two dragons using a helical CT scanner. All sections were displayed with a bone [...] Read more.
This study aimed to describe the anatomic features of the normal head of the Komodo dragon (Varanus komodoensis) identified by computed tomography. CT images were obtained in two dragons using a helical CT scanner. All sections were displayed with a bone and soft tissue windows setting. Head reconstructed, and maximum intensity projection images were obtained to enhance bony structures. After CT imaging, the images were compared with other studies and reptile anatomy textbooks to facilitate the interpretation of the CT images. Anatomic details of the head of the Komodo dragon were identified according to the CT density characteristics of the different organic tissues. This information is intended to be a useful initial anatomic reference in interpreting clinical CT imaging studies of the head and associated structures in live Komodo dragons. Full article
(This article belongs to the Special Issue Advances in Animal Anatomy)
Show Figures

Figure 1

Back to TopTop