Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (113)

Search Parameters:
Keywords = glazed façade

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
19 pages, 2441 KiB  
Article
Simulation and Statistical Validation Method for Evaluating Daylighting Performance in Hot Climates
by Nivin Sherif, Ahmed Yehia and Walaa S. E. Ismaeel
Urban Sci. 2025, 9(8), 303; https://doi.org/10.3390/urbansci9080303 - 4 Aug 2025
Abstract
This study investigates the influence of façade-design parameters on daylighting performance in hot arid climates, with a particular focus on Egypt. A total of nine façade configurations of a residential building were modeled and simulated using Autodesk Revit and Insight 360, varying three [...] Read more.
This study investigates the influence of façade-design parameters on daylighting performance in hot arid climates, with a particular focus on Egypt. A total of nine façade configurations of a residential building were modeled and simulated using Autodesk Revit and Insight 360, varying three critical variables: glazing type (clear, blue, and dark), Window-to-Wall Ratio (WWR) of 15%, 50%, 75%, and indoor wall finish (light, moderate, dark) colors. These were compared to the Leadership in Energy and Environmental Design (LEED) daylighting quality thresholds. The results revealed that clear glazing paired with high WWR (75%) achieved the highest Spatial Daylight Autonomy (sDA), reaching up to 92% in living spaces. However, this also led to elevated Annual Sunlight Exposure (ASE), with peak values of 53%, exceeding the LEED discomfort threshold of 10%. Blue and dark glazing types successfully reduced ASE to as low as 0–13%, yet often resulted in underlit spaces, especially in private rooms such as bedrooms and bathrooms, with sDA values falling below 20%. A 50% WWR emerged as the optimal balance, providing consistent daylight distribution while maintaining ASE within acceptable limits (≤33%). Similarly, moderate color wall finishes delivered the most balanced lighting performance, enhancing sDA by up to 30% while controlling reflective glare. Statistical analysis using Pearson correlation revealed a strong positive relationship between sDA and ASE (r = 0.84) in highly glazed, clear glass scenarios. Sensitivity analysis further indicated that low WWR configurations of 15% were highly influenced by glazing and finishing types, leading to variability in daylight metrics reaching ±40%. The study concludes that moderate glazing (blue), medium WWR (50%), and moderate color indoor finishes provide the most robust daylighting performance across diverse room types. These findings support an evidence-based approach to façade design, promoting visual comfort, daylight quality, and sustainable building practices. Full article
(This article belongs to the Topic Application of Smart Technologies in Buildings)
Show Figures

Figure 1

23 pages, 5813 KiB  
Article
Integrated Lighting and Solar Shading Strategies for Energy Efficiency, Daylighting and User Comfort in a Library Design Proposal
by Egemen Kaymaz and Banu Manav
Buildings 2025, 15(15), 2669; https://doi.org/10.3390/buildings15152669 - 28 Jul 2025
Viewed by 164
Abstract
This research proposes an integrated lighting and solar shading strategy to improve energy efficiency and user comfort in a retrofit project in a temperate-humid climate. The study examines a future library addition to an existing faculty building in Bursa, featuring highly glazed façades [...] Read more.
This research proposes an integrated lighting and solar shading strategy to improve energy efficiency and user comfort in a retrofit project in a temperate-humid climate. The study examines a future library addition to an existing faculty building in Bursa, featuring highly glazed façades (77% southwest, 81% northeast window-to-wall ratio), an open-plan layout, and situated within an unobstructed low-rise campus environment. Trade-offs between daylight availability, heating, cooling, lighting energy use, and visual and thermal comfort are evaluated through integrated lighting (DIALux Evo), climate-based daylight (CBDM), and energy simulations (DesignBuilder, EnergyPlus, Radiance). Fifteen solar shading configurations—including brise soleil, overhangs, side fins, egg crates, and louvres—are evaluated alongside a daylight-responsive LED lighting system that meets BS EN 12464-1:2021. Compared to the reference case’s unshaded glazing, optimal design significantly improves building performance: a brise soleil with 0.4 m slats at 30° reduces annual primary energy use by 28.3% and operational carbon emissions by 29.1% and maintains thermal comfort per ASHRAE 55:2023 Category II (±0.7 PMV; PPD < 15%). Daylight performance achieves 91.5% UDI and 2.1% aSE, with integrated photovoltaics offsetting 129.7 kWh/m2 of grid energy. This integrated strategy elevates the building’s energy class under national benchmarks while addressing glare and overheating in the original design. Full article
(This article belongs to the Special Issue Lighting in Buildings—2nd Edition)
Show Figures

Figure 1

3 pages, 155 KiB  
Editorial
Phase Change Materials for Building Energy Applications
by Facundo Bre, Antonio Caggiano and Umberto Berardi
Energies 2025, 18(13), 3534; https://doi.org/10.3390/en18133534 - 4 Jul 2025
Viewed by 325
Abstract
This editorial introduces the Special Issue entitled “Phase Change Materials for Building Energy Applications”, which gathers nine original research articles focused on advancing thermal energy storage solutions in the built environment. The selected contributions explore the application of phase change materials (PCMs) across [...] Read more.
This editorial introduces the Special Issue entitled “Phase Change Materials for Building Energy Applications”, which gathers nine original research articles focused on advancing thermal energy storage solutions in the built environment. The selected contributions explore the application of phase change materials (PCMs) across a range of building components and systems, including façades, flooring, glazing, and pavements, aimed at enhancing energy efficiency, reducing peak loads, and improving thermal comfort. This Special Issue highlights both experimental and numerical investigations, ranging from nanomaterial-enhanced PCMs and solid–solid PCM glazing systems to full-scale applications and the modeling of encapsulated PCM geometries. Collectively, these studies reflect the growing potential of PCMs to support sustainable, low-carbon construction and provide new insights into material design, system optimization, and energy resilience. We thank all contributing authors and reviewers for their valuable input and hope that this Special Issue serves as a resource for ongoing innovation in the field. Full article
(This article belongs to the Special Issue Phase Change Materials for Building Energy Applications)
21 pages, 3571 KiB  
Article
An Experimental Study of Wind-Driven Ventilation with Double Skin Facade During Transition Seasons
by Guoqing He, Zhewen Fan, Yuan Meng, Linfeng Yao and Changqing Ye
Energies 2025, 18(13), 3249; https://doi.org/10.3390/en18133249 - 21 Jun 2025
Viewed by 340
Abstract
Double skin facade (DSF) is an energy-efficient solution for glazing facades. However, previous studies have reported inconsistent findings regarding thermal comfort in naturally ventilated DSF buildings. To examine this issue, this study evaluated airflow velocities in naturally ventilated DSF buildings during transition seasons [...] Read more.
Double skin facade (DSF) is an energy-efficient solution for glazing facades. However, previous studies have reported inconsistent findings regarding thermal comfort in naturally ventilated DSF buildings. To examine this issue, this study evaluated airflow velocities in naturally ventilated DSF buildings during transition seasons through a comparative study approach. A full-scale box-type DSF room and a traditional window-wall room were simultaneously monitored in a laboratory building under real climatic conditions, with indoor environmental parameters recorded for 10 days. Airflow sensation surveys complemented the physical measurements to evaluate perceived comfort. The results showed that the DSF room consistently exhibited lower air velocities (≤0.2 m/s) compared to the traditional room, demonstrating minimal response to wind conditions related to its small openings (opening ratio of 4.7%) and increased flow resistance from the dual-layer structure of the DSF. Under unfavorable wind conditions, the DSF room demonstrated higher ventilation rates due to the enhanced stack effect. However, this advantage had a negligible effect on the thermal comfort vote for the indoor temperature range (26 °C to 28 °C). These findings highlight the climate-dependent performance of DSFs: while advantageous for thermal comfort in cooler climates, they may lead to reduced thermal comfort in warm and hot climates due to low indoor airflow velocities. Future work could include the optimization of DSF opening configurations to enhance wind-driven ventilation while maintaining stack ventilation benefits. Full article
(This article belongs to the Special Issue Energy Efficiency and Energy Performance in Buildings—2nd Edition)
Show Figures

Figure 1

27 pages, 7310 KiB  
Article
Energy and Thermal Comfort Performance of Vacuum Glazing-Based Building Envelope Retrofit in Subtropical Climate: A Case Study
by Changyu Qiu, Hongxing Yang and Kaijun Dong
Buildings 2025, 15(12), 2038; https://doi.org/10.3390/buildings15122038 - 13 Jun 2025
Viewed by 826
Abstract
In the context of global warming, building transformation takes on a dual responsibility to be more energy-efficient and sustainable for climate change mitigation and to be more climate-resilient for occupants’ comfort. The building energy retrofitting is an urgent need due to the large [...] Read more.
In the context of global warming, building transformation takes on a dual responsibility to be more energy-efficient and sustainable for climate change mitigation and to be more climate-resilient for occupants’ comfort. The building energy retrofitting is an urgent need due to the large amount of existing building stock. Especially in high-rise and high-density cities under a subtropical climate, like Hong Kong, existing buildings with large glazed façades face the challenges of high energy consumption and overheating risks. An advanced glazing system, namely the vacuum insulating glazing (VIG), shows the potential for effective building envelope retrofitting due to its excellent thermal insulation ability. Yet, its performance for practical applications in the subtropical region has not been investigated. To enhance the energy performance and thermal comfort of existing high-rise buildings, this study proposed a novel retrofitting approach by integrating the VIG into the existing window system as secondary glazing. Field experiments were conducted in a commercial building in Hong Kong to investigate the thermal performance of the VIG retrofit application under real-world conditions. Furthermore, the energy-saving potential and thermal comfort performance of the VIG retrofit were evaluated by building energy simulations. The experimental results indicate that the VIG retrofit can effectively stabilize the fluctuation of the inside glass surface temperature and significantly reduce the heat gain by up to 85.3%. The simulation work shows the significant energy-saving potential of the VIG retrofit in Hong Kong. For the VIG retrofit cases under different scenarios, the energy-saving potential varies from 12.5% to 29.7%. In terms of occupants’ thermal comfort, the VIG retrofit can significantly reduce the overheating risk and improve thermal satisfaction by 9.2%. Due to the thermal comfort improvement, the cooling setpoint could be reset to 1 °C higher without compromising the overall thermal comfort. The average payback period for the VIG application is 5.8 years and 8.6 years for the clear glass retrofit and the coated glass retrofit, respectively. Therefore, the VIG retrofit approach provides a promising solution for building envelope retrofits under subtropical climate conditions. It not only benefits building owners and occupants but also contributes to achieving long-term climate resilience and the carbon neutrality of urban areas. Full article
Show Figures

Figure 1

35 pages, 16910 KiB  
Article
A Simplified Model Validation for the Energy Assessment of Opaque Adaptive Façades with Variable Thermal Resistance
by Ismael Palacios Mackay, Laura Marín-Restrepo and Alexis Pérez-Fargallo
Energies 2025, 18(11), 2682; https://doi.org/10.3390/en18112682 - 22 May 2025
Viewed by 668
Abstract
Adaptive façades, also known as climate-adaptive building shells (CABSs), could make a significant contribution towards reducing the energy consumption of buildings and their environmental impacts. There is extensive research on glazed adaptive façades, mainly due to the available technology for glass materials. The [...] Read more.
Adaptive façades, also known as climate-adaptive building shells (CABSs), could make a significant contribution towards reducing the energy consumption of buildings and their environmental impacts. There is extensive research on glazed adaptive façades, mainly due to the available technology for glass materials. The technological development of opaque adaptive façades has focused on variable-thermal-resistance envelopes, and the simulation of this type of façade is a challenging task that has not been thoroughly studied. The aim of this study was to configure and validate a simplified office model that could be used for simulating an adaptive façade with variable thermal resistance via adaptive insulation thickness in its opaque part. Software-to-software model comparison based on the results of an EnergyPlus Building Energy Simulation Test 900 (BesTest 900)-validated model was used. Cooling and heating annual energy demand (kWh), peak cooling and heating (kW), and maximum, minimum, and average annual hourly zone temperature variables were compared for both the Adaptive and non-adaptive validated model. An Adaptive EnergyPlus model based on the BesTest 900 model, which uses the EnergyPlus SurfaceControl:MovableInsulation class list, was successfully validated and could be used for studying office buildings with a variable-thermal-resistance adaptive façade wall configuration, equivalent to a heavyweight mass wall construction with an External Insulation Finishing System (EIFS). An example of the Adaptive model in the Denver location is included in this paper. Annual savings of up to 26% in total energy demand (heating + cooling) was achieved and could reach up to 54% when electro-chromic (EC) glass commanded by a rule-based algorithm was added to the glazed part of the variable-thermal-resistance adaptive façade. Full article
(This article belongs to the Special Issue Advanced Building Materials for Energy Saving—2nd Edition)
Show Figures

Figure 1

17 pages, 8243 KiB  
Article
Assessment of Shading Systems with Advanced Windows at Restaurants Under Sunny Climates in Spain
by Urtza Uriarte, Olatz Irulegi and Rufino J. Hernández
Buildings 2025, 15(7), 1173; https://doi.org/10.3390/buildings15071173 - 3 Apr 2025
Viewed by 519
Abstract
This study addresses daylighting to enhance the quality of indoor atmospheres, considering building skins. In the hotel industry, lighting accounts for more than 10% of energy consumption. Many highly glazed façades create visual comfort problems, resulting in increased electric lighting consumption. Ninety-four restaurants [...] Read more.
This study addresses daylighting to enhance the quality of indoor atmospheres, considering building skins. In the hotel industry, lighting accounts for more than 10% of energy consumption. Many highly glazed façades create visual comfort problems, resulting in increased electric lighting consumption. Ninety-four restaurants were studied in Spain; almost all cases have a window with outside views, and more than half of the cases have tables adjacent to the outside views. However, it is difficult to balance daylight use, a shading system, and the outside view. A virtual restaurant prototype is built by Rhinoceros to simulate the daylight glare index by Evalglare and daylight autonomy of a highly glazed façade with three different shading systems by Radiance through a screen and an overhang with and without a complex fenestration system. The results show that the screen system reduces the daylight glare index value to imperceptible glare (15%), while the daylight glare index for the overhang with and without a complex fenestration system increases to acceptable glare (21%). However, the daylight autonomy for the screen system is almost half (52%) the daylight autonomy for the overhang systems (95%). Although the daylight glare index for the overhang with a complex fenestration system is slightly higher, the illuminance level and its distribution performance are better without obstructing the outdoor view. Full article
Show Figures

Figure 1

29 pages, 7662 KiB  
Review
Advancements in MEMS Micromirror and Microshutter Arrays for Light Transmission Through a Substrate
by Shilby Baby, Mustaqim Siddi Que Iskhandar, Md Kamrul Hasan, Steffen Liebermann, Jiahao Chen, Hasnain Qasim, Shujie Liu, Eslam Farrag, Dennis Löber, Naureen Ahmed, Guilin Xu and Hartmut Hillmer
Micromachines 2025, 16(1), 103; https://doi.org/10.3390/mi16010103 - 16 Jan 2025
Cited by 3 | Viewed by 1487
Abstract
This paper reviews and compares electrostatically actuated MEMS (micro-electro-mechanical system) arrays for light modulation and light steering in which transmission through the substrate is required. A comprehensive comparison of the technical achievements of micromirror arrays and microshutter arrays is provided. The main focus [...] Read more.
This paper reviews and compares electrostatically actuated MEMS (micro-electro-mechanical system) arrays for light modulation and light steering in which transmission through the substrate is required. A comprehensive comparison of the technical achievements of micromirror arrays and microshutter arrays is provided. The main focus of this paper is MEMS micromirror arrays for smart glass in building windows and façades. This technology utilizes millions of miniaturized and actuatable micromirrors on transparent substrates, enabling use with transmissive substrates such as smart windows for personalized daylight steering, energy saving, and heat management in buildings. For the first time, subfield-addressable MEMS micromirror arrays with an area of nearly 1 m2 are presented. The recent advancements in MEMS smart glass technology for daylight steering are discussed, focusing on aspects like the switching speed, scalability, transmission, lifetime study, and reliability of micromirror arrays. Finally, simulations demonstrating the potential yearly energy savings for investments in MEMS smart glazing are presented, including a comparison to traditional automated external blind systems in a model office room with definite user interactions throughout the year. Additionally, this platform technology with planarized MEMS elements can be used for laser safety goggles to shield pilots, tram, and bus drivers as well as security personal from laser threats, and is also presented in this paper. Full article
Show Figures

Figure 1

25 pages, 13246 KiB  
Article
Optimization of the Dynamic External Shading Control for Railway Stations in China Based on Energy Use Intensity (EUI) of Lighting and HVAC Systems
by Haijun Zhang and Pengcheng Jiang
Buildings 2024, 14(12), 3886; https://doi.org/10.3390/buildings14123886 - 4 Dec 2024
Viewed by 1010
Abstract
Railway stations are normally designed with glazing façades and skylights to achieve aesthetic requirements and facilitate visual permeability, but this design can lead to significant energy consumption. The implementation of dynamic external shading systems together with appropriate control strategies can significantly reduce the [...] Read more.
Railway stations are normally designed with glazing façades and skylights to achieve aesthetic requirements and facilitate visual permeability, but this design can lead to significant energy consumption. The implementation of dynamic external shading systems together with appropriate control strategies can significantly reduce the energy consumption of HVAC systems. This study numerically investigated the lighting and cooling energy consumption of railway stations equipped with external shading systems under various climatic zones, window-to-wall ratios (WWRs), skylight-to-roof ratios (SRRs) and roller-shade performance. The study shows that lighting energy consumption varies most significantly when the shading activation threshold is set between 50 and 200 W/m2. The dynamic shading thresholds are influenced by natural lighting and solar heat gain, with the strategy changing from using natural light to reducing solar gain as the SRR increases. This study also provides the optimal activation thresholds and energy-saving rates for railway station buildings in different climatic zones using external roller shades for different external window scenarios. In Guangzhou, using roller shade A in a railway station under the maximum external window scenario achieves energy savings of 36.41%, while in Shanghai and Beijing, the energy savings are 18.12% and 23.13%, respectively. These results provide guidance for the use of dynamic external shading in railway stations in China and for the achievement of energy-reduction targets in the transport and building industries. Full article
Show Figures

Figure 1

19 pages, 4517 KiB  
Article
Assessment of the Actual and Required Cooling Demand for Buildings with Extensive Transparent Surfaces
by Attila Kostyák, Szabolcs Szekeres and Imre Csáky
Energies 2024, 17(23), 5814; https://doi.org/10.3390/en17235814 - 21 Nov 2024
Viewed by 710
Abstract
Energy consumption in buildings with large, glazed facades rises markedly in the summer, driven by cooling demands that vary with structural characteristics and external climate conditions. This study is unique in examining daily cooling needs in lightweight and heavyweight constructions, utilizing meteorological data [...] Read more.
Energy consumption in buildings with large, glazed facades rises markedly in the summer, driven by cooling demands that vary with structural characteristics and external climate conditions. This study is unique in examining daily cooling needs in lightweight and heavyweight constructions, utilizing meteorological data from 782 summer days in Debrecen, Hungary. Unlike standard approaches, which often overlook localized meteorological variables, this analysis focuses on actual “clear sky” scenarios across distinct summer day types: normal, hot, and torrid. The findings indicate that orientation and construction type significantly affect cooling demands, with east-facing rooms demanding up to 14.2% more cooling in lightweight structures and up to 35.8% in heavyweight structures during peak hours (8 a.m. to 4 p.m.). This study reveals that for west-facing facades, extending use beyond 4 p.m. markedly increases energy loads. Furthermore, the cooling demand peak for heavyweight buildings occurs later in the day, driven by their higher thermal capacity. These insights underscore the importance of aligning HVAC system design with operational schedules and building orientation, offering data-driven strategies to enhance energy efficiency in buildings with diverse thermal and solar exposure profiles. Full article
(This article belongs to the Special Issue Energy Efficiency of the Buildings: 3rd Edition)
Show Figures

Figure 1

21 pages, 3075 KiB  
Article
Façade Retrofit Strategies for Energy Efficiency Improvement Considering the Hot Climatic Conditions of Saudi Arabia
by Wesam Rababa and Omar S. Asfour
Appl. Sci. 2024, 14(21), 10003; https://doi.org/10.3390/app142110003 - 1 Nov 2024
Cited by 4 | Viewed by 2320
Abstract
Saudi Arabia faces significant challenges in managing the rising energy consumption in buildings driven largely by its hot climatic conditions. As a result, retrofitting building facades to enhance energy efficiency has become a critical strategy. This study assesses the effectiveness of various façade [...] Read more.
Saudi Arabia faces significant challenges in managing the rising energy consumption in buildings driven largely by its hot climatic conditions. As a result, retrofitting building facades to enhance energy efficiency has become a critical strategy. This study assesses the effectiveness of various façade retrofit strategies in reducing cooling electricity consumption using a real-time case study in Dhahran, Saudi Arabia. The strategies explored include external wall upgrades, window replacements, and installation of shading devices. Each strategy was evaluated individually, considering the reduction in heat gains, cooling load, and payback period as key performance indicators. To further maximize energy efficiency, these strategies were also analyzed in combination using the genetic algorithm optimization method, yielding 224 possible facade configurations. The optimal solution included the use of an External Thermal Insulation Composite System (ETCIS) in walls, louvers in windows, and low-emissivity coating with Argon gas-filled glazing, achieving a cooling energy reduction of approximately 16% and a payback period of 14.8 years. This study provides several recommendations for improving the efficiency of retrofitting building façades in hot climatic conditions. Full article
Show Figures

Figure 1

15 pages, 3644 KiB  
Article
A Calculation Study on the Escape of Incident Solar Radiation in Buildings with Glazing Facades
by Shunyao Lu, Zhengzhi Wang and Tao Chen
Buildings 2024, 14(11), 3497; https://doi.org/10.3390/buildings14113497 - 31 Oct 2024
Cited by 1 | Viewed by 1004
Abstract
More and more modern buildings are using glass curtain walls as their building envelope. The large area of window leads to a significant increase in solar heat gain, resulting in an increase in the cooling load and energy consumption of the building envelope. [...] Read more.
More and more modern buildings are using glass curtain walls as their building envelope. The large area of window leads to a significant increase in solar heat gain, resulting in an increase in the cooling load and energy consumption of the building envelope. In the calculation of building cooling load, the thermal performance parameter of windows, the solar heat gain coefficient, is used to calculate the solar radiation heat gain of the windows. The window-to-wall ratio of buildings with glazing facades is large, and the phenomenon of escape of incident solar radiation cannot be ignored. In order to calculate the solar radiation escape rate, a dynamic model of solar radiation escape rate incorporating the solar path tracking model is developed in this research, which can achieve big data simulation analysis based on actual meteorological conditions. The model is programmed and simulated using MATLAB R2024a software. Five representative cities from different climate regions in China are selected and the variation rule of solar radiation escape rate are analyzed on three different time scales: day, month, and year. The influence of building orientation was also calculated and analyzed. The numerical calculation results indicate that the escape solar radiation rate varies with the incident angle of solar radiation at different times. It was found that the smaller the solar azimuth angle and solar altitude angle, the smaller the escape rate of solar radiation. The latitude of a city has a significant impact on the solar radiation escape rate. The weighted average of the solar radiation escape rates for each city were calculated for both summer and winter. Regardless of the season, the city’s location, and the orientation of the room, the value of solar radiation escape rate varies from 8.64% to 10.33%, which indicates that the solar radiation escape phenomenon cannot be ignored in glass curtain wall buildings. The results can be used as a reference value of solar radiation escape rate for the correction of actual solar heat gain of buildings in different climate regions. Full article
(This article belongs to the Section Building Energy, Physics, Environment, and Systems)
Show Figures

Figure 1

19 pages, 8192 KiB  
Article
Experimental and Numerical Studies of Heat Transfer Through a Double-Glazed Window with Electric Heating of the Glass Surface
by Hanna Koshlak, Borys Basok, Anatoliy Pavlenko, Svitlana Goncharuk, Borys Davydenko and Jerzy Piotrowski
Sustainability 2024, 16(21), 9374; https://doi.org/10.3390/su16219374 - 29 Oct 2024
Cited by 2 | Viewed by 2057
Abstract
This paper presents experimental and theoretical studies of heat transfer through single- and double-glazed windows with electrical heating of the internal surfaces. Heating is achieved by applying a voltage to the low emissivity coating of the inner glass. A thermophysical model has been [...] Read more.
This paper presents experimental and theoretical studies of heat transfer through single- and double-glazed windows with electrical heating of the internal surfaces. Heating is achieved by applying a voltage to the low emissivity coating of the inner glass. A thermophysical model has been developed to simulate the heat transfer through these units, allowing us to determine their thermal characteristics. Experimental data are used to validate the numerical model. The resulting heat flux and temperature distributions on the external and internal surfaces of electrically heated double-glazed units are analysed. According to the results of experimental and numerical studies, it was found that the adopted electric heating scheme allows 83–85% of the heat to enter the room and 15–17% is removed to the outside. This makes it possible to increase the radiation component of the heat flow from the window to the room and improve the thermal comfort in the room. In general, this article shows that existing industrial windows with low-emissivity glass surface coating can be upgraded with simple and inexpensive modernisation, without compromising the main function of the window—efficient transmission of visible light—and create an additional (backup) heating device that can work effectively together with the existing heating system in the event of a sudden cold snap at low temperatures (below −20 °C), to prevent condensation of water vapour in the windows, and to prevent condensation on the surface of the window facade wall. Formally, a back-up (emergency) heating system is created in the room, which contributes to the energy sustainability of the building and therefore to energy security in general. Full article
(This article belongs to the Section Energy Sustainability)
Show Figures

Figure 1

25 pages, 9379 KiB  
Article
Exploring Built Environment Visual Interactions: A SoftBIM Data-Driven Approach for a Database About the Outdoor View
by Matteo Cavaglià, Alberto Speroni, Juan Diego Blanco Cadena, Andrea Giovanni Mainini and Tiziana Poli
Buildings 2024, 14(11), 3340; https://doi.org/10.3390/buildings14113340 - 22 Oct 2024
Viewed by 1073
Abstract
Windows and glazed facades provide outdoor views, serving as vital sources of visual information that aid navigation and interaction within buildings. These views can trigger psychological and physiological responses, affecting individual well-being. However, optimizing outdoor view quality is challenging due to the complex [...] Read more.
Windows and glazed facades provide outdoor views, serving as vital sources of visual information that aid navigation and interaction within buildings. These views can trigger psychological and physiological responses, affecting individual well-being. However, optimizing outdoor view quality is challenging due to the complex interplay of factors influencing the building’s experience of vision. Managing the complexity of optimizing outdoor view quality within current digital frameworks for building design presents significant challenges. A key issue lies in the ambiguity of certain visual metrics, which are often difficult to translate into explicit descriptors of spatial configurations. Even when such metrics are available, their practical use as guiding tools in the design process is frequently obstructed by complex data interoperability procedures. These procedures are necessary to enable seamless data transfer across the multiple software environments involved in the design process. This study advocates for the softBIM paradigm, which optimizes workflows by embedding visual analysis results into target geometries. Supported by this process, the calculation of a metric to measure the impact of existing and planned visual obstructions on the vision of the targeted landmarks is proposed and analysed. This metric is specifically applied to assess the visual information incoming to the vertical facades of building envelopes, a context of application that denotes criteria of assessment different from the ones usually applied in the most established frameworks for visual analysis (e.g., isovist analysis). SoftBIM enables effective automation strategies to aid the metric computation and the processing of the results to implement seamless export and data implementation. The visual metric is built upon implementing the Ladybug suite and addresses the different limitations in the target-based visibility calculation supported by the tool. Full article
(This article belongs to the Special Issue Energy Consumption and Environmental Comfort in Buildings)
Show Figures

Figure 1

18 pages, 2384 KiB  
Article
Application of PV on Commercial Building Facades: An Investigation into the Impact of Architectural and Structural Features
by Belal Ghaleb, Muhammad Imran Khan and Muhammad Asif
Sustainability 2024, 16(20), 9095; https://doi.org/10.3390/su16209095 - 21 Oct 2024
Cited by 4 | Viewed by 2000
Abstract
The rapid global transition toward renewable energy necessitates innovative solar PV deployment strategies beyond conventional roof installations. In this context, commercial building facades represent an expansive yet underutilized resource for solar energy harvesting in urban areas. However, existing studies on commercial rooftop solar [...] Read more.
The rapid global transition toward renewable energy necessitates innovative solar PV deployment strategies beyond conventional roof installations. In this context, commercial building facades represent an expansive yet underutilized resource for solar energy harvesting in urban areas. However, existing studies on commercial rooftop solar PV predominantly focus on European contexts, neglecting the unique design constraints and performance trade-offs present in regions such as the Middle East. This study addresses this gap by specifically investigating the impact of architectural and structural features on the utilizable facade area for PV deployment in commercial buildings within the hot desert climate of Saudi Arabia. Detailed case studies of twelve representative buildings are conducted, combining architectural drawing analysis, on-site measurements, and stakeholder surveys. The methodology identified sixteen parameters across three categories—facade functionality, orientation suitability, and surrounding obstructions—that impose technical and non-technical restrictions on photovoltaic integration 3D modeling, and irradiance simulations revealed that, on average, just 31% of the total vertical facade area remained suitable for PV systems after accounting for the diverse architectural and contextual limitations. The study considered 698 kWh/m2 of solar irradiance as the minimum threshold for PV integration. Shopping malls displayed the lowest utilizability, with near-zero potential, as extensive opaque construction, brand signage, and shading diminish viability. Offices exhibited the highest utilizability of 36%, owing to glazed facades and unobstructed surroundings. Hotels and hospitals presented intermediate potential. Overall, the average facade utilizability factor across buildings was a mere 16%, highlighting the significant hurdles imposed by contemporary envelope configurations. Orientation unsuitability further eliminated 12% of the initially viable area. Surrounding shading contributed an additional 0.92% loss. The results quantify the sensitivity of facades to aspects such as material choices, geometric complexity, building form, and urban context. While posing challenges, the building facade resource holds immense untapped potential for solar-based urban renewal. The study highlights the need for early architectural integration, facade-specific PV product development, and urban planning interventions to maximize the renewable energy potential of commercial facades as our cities rapidly evolve into smart solar energy landscapes. Full article
Show Figures

Figure 1

Back to TopTop