Article
Effect of Different Surface Treatments as Methods of Improving the Mechanical Properties after Repairs of PMMA for Dentures
by Grzegorz Chladek, Sandra Adeeb, Wojciech Pakieła and Neide Pena Coto
Materials 2024, 17(13), 3254; https://doi.org/10.3390/ma17133254 - 2 Jul 2024
Cited by 2 | Viewed by 1967
Abstract
Denture fractures are a common problem in dental practice, and their repair is considered a first option to restore their functional properties. However, the inter-material resistance may become compromised. Typically, the bond between these materials weakens. Therefore, various surface treatment methods may be [...] Read more.
Denture fractures are a common problem in dental practice, and their repair is considered a first option to restore their functional properties. However, the inter-material resistance may become compromised. Typically, the bond between these materials weakens. Therefore, various surface treatment methods may be considered to enhance their mechanical properties. Poly(methyl methacrylate) (PMMA) heat-polymerized resin (HPR) was used as the repaired material, cold-polymerized material (CPR) for the repairs, and different variants of alumina abrasive blasting (AB), methyl methacrylate (M), ethyl acetate (EA), methylene chloride (CH), and isopropyl alcohol (IA) treatments were applied. Finally, combined surface treatments were chosen and analyzed. Surface morphologies after treatments were observed by scanning electron microscopy and the flexural, shear, and impact strengths were tested. AB and chemical treatment with CH, M, and EA was used to improve all mechanical properties, and further improvement of the properties could be achieved by combining both types of treatments. Varied changes in surface morphologies were observed. Treatment with IA yielded less favorable results due to the low impact strength. The best results were achieved for the combination of AB and CH, but during the application of CH it was necessary to strictly control the exposure time. Full article
(This article belongs to the Special Issue Advances in Biomaterials for Dental Applications)
Show Figures

Figure 1

13 pages, 5992 KB  
Article
A Retrospective Evaluation of 5 Years of Clinical Results of Metal–Ceramic vs. Monolithic Zirconia Superstructures in Maxillary All-on-4TM Concept
by Mustafa Ayna and Søren Jepsen
J. Clin. Med. 2024, 13(2), 557; https://doi.org/10.3390/jcm13020557 - 18 Jan 2024
Cited by 4 | Viewed by 2459
Abstract
The aim of the current study was to present the clinical and radiological outcomes of monolithic zirconia superstructures compared to the metal–ceramic ones in the All-on-4 concept for the prosthetic rehabilitation of the maxillae. A total of 30 patients were subdivided into groups [...] Read more.
The aim of the current study was to present the clinical and radiological outcomes of monolithic zirconia superstructures compared to the metal–ceramic ones in the All-on-4 concept for the prosthetic rehabilitation of the maxillae. A total of 30 patients were subdivided into groups according to their superstructure type (metal–ceramic (n = 15) or monolithic zirconia (n = 15)). All implants were functionally loaded within 24 h after insertion with provisional acrylic superstructures. Prosthetic complications, marginal bone loss, plaque accumulation, probing pocket depth, bleeding on probing, and bite force were documented over a period of 5 years. Marginal bone loss around the implants of the ceramic group remained well over the five years (1.21 ± 0.23 mm). However, marginal bone loss was significantly lower around the implants in the monolithic zirconia group (0.22 ± 0.14 mm) (p < 0.001). Bleeding on probing, plaque accumulation, and probing pocket depth values were correlated with marginal bone loss. Among all evaluated parameters, no differences could be detected in terms of the angulation of the implants. Detachment or chipping was observed in seven cases in the metal–ceramic superstructure group. In all cases, dentures were removed and repaired in the laboratory. In the monolithic zirconia group, chipping was detected after one year in two cases, after two years in four cases, and after five years in one case and could be managed by polishing in situ. Monolithic zirconia superstructures presented superior results regarding the parameters evaluated. Full article
(This article belongs to the Section Dentistry, Oral Surgery and Oral Medicine)
Show Figures

Figure 1

10 pages, 249 KB  
Review
The Impact of Xerostomia on Food Choices—A Review with Clinical Recommendations
by Frauke Müller, Najla Chebib, Sabrina Maniewicz and Laurence Genton
J. Clin. Med. 2023, 12(14), 4592; https://doi.org/10.3390/jcm12144592 - 10 Jul 2023
Cited by 24 | Viewed by 8296
Abstract
Xerostomia and hyposalivation are highly prevalent conditions in old age, particularly among multimorbid elders, and are often attributed to the use of multiple medications. These conditions negatively affect oral functions, such as chewing, swallowing, speech, and taste. Additionally, the lack of lubrication of [...] Read more.
Xerostomia and hyposalivation are highly prevalent conditions in old age, particularly among multimorbid elders, and are often attributed to the use of multiple medications. These conditions negatively affect oral functions, such as chewing, swallowing, speech, and taste. Additionally, the lack of lubrication of the oral mucosa frequently leads to super-infections with candida. Denture retention and comfort may also be compromised. The risk of dental caries and erosion of natural teeth increases since saliva, which is essential for repairing initial lesions in tooth structures, is insufficient. The dry sensation in the mouth also impacts the emotional and social well-being of elderly individuals. Patients experiencing xerostomia often avoid certain foods that are uncomfortable or difficult to consume. However, some foods may alleviate the symptoms or even stimulate salivation. This review discusses the limited available evidence on nutritional advice for patients with xerostomia and aims to provide insight into the patient’s perspective while offering clinical recommendations. Future studies should focus on investigating the nutritional intake of individuals suffering from xerostomia or hyposalivation in order to ensure oral health comfort, prevent malnutrition, and minimize the impact on their quality of life. Full article
18 pages, 8973 KB  
Review
Multiple-Ion Releasing Bioactive Surface Pre-Reacted Glass-Ionomer (S-PRG) Filler: Innovative Technology for Dental Treatment and Care
by Satoshi Imazato, Toshiyuki Nakatsuka, Haruaki Kitagawa, Jun-Ichi Sasaki, Satoshi Yamaguchi, Shuichi Ito, Hiroki Takeuchi, Ryota Nomura and Kazuhiko Nakano
J. Funct. Biomater. 2023, 14(4), 236; https://doi.org/10.3390/jfb14040236 - 21 Apr 2023
Cited by 50 | Viewed by 8639
Abstract
Surface Pre-Reacted Glass-ionomer (S-PRG) filler, which releases strontium (Sr2+), borate (BO33−), fluoride (F), sodium (Na+), silicate (SiO32−), and aluminum (Al3+) ions at high concentrations, is a unique glass filler [...] Read more.
Surface Pre-Reacted Glass-ionomer (S-PRG) filler, which releases strontium (Sr2+), borate (BO33−), fluoride (F), sodium (Na+), silicate (SiO32−), and aluminum (Al3+) ions at high concentrations, is a unique glass filler that are utilized in dentistry. Because of its multiple-ion releasing characteristics, S-PRG filler exhibits several bioactivities such as tooth strengthening, acid neutralization, promotion of mineralization, inhibition of bacteria and fungi, inhibition of matrix metalloproteinases, and enhancement of cell activity. Therefore, S-PRG filler per se and S-PRG filler-containing materials have the potential to be beneficial for various dental treatments and care. Those include restorative treatment, caries prevention/management, vital pulp therapy, endodontic treatment, prevention/treatment of periodontal disease, prevention of denture stomatitis, and perforation repair/root end filling. This review summarizes bioactive functions exhibited by S-PRG filler and its possible contribution to oral health. Full article
(This article belongs to the Special Issue Functional Materials for Dental Restorations)
Show Figures

Figure 1

22 pages, 669 KB  
Systematic Review
Technical Complications of Removable Partial Dentures in the Moderately Reduced Dentition: A Systematic Review
by Marie-Theres Dawid, Ovidiu Moldovan, Heike Rudolph, Katharina Kuhn and Ralph G. Luthardt
Dent. J. 2023, 11(2), 55; https://doi.org/10.3390/dj11020055 - 20 Feb 2023
Cited by 9 | Viewed by 8309
Abstract
The aim of this study was to conduct a systematic literature review with a subsequent meta-analysis on the technical complications and failures of removable partial denture (RPD) therapy in the moderately reduced dentition. A systematic literature search of established medical databases, last updated [...] Read more.
The aim of this study was to conduct a systematic literature review with a subsequent meta-analysis on the technical complications and failures of removable partial denture (RPD) therapy in the moderately reduced dentition. A systematic literature search of established medical databases, last updated 06/2022, was conducted. RCTs and prospective and retrospective studies were included that had information on technical complications and failures of RPDs, at least 15 participants, an observation period of at least two years and a drop-out rate of less than 25%. Publications were selected on the title, abstract and full-text level by at least three of the participating authors. The evidence of the included studies was classified using the GRADE system. The bias risk was determined using the RoB2 tool and the ROBINS-I tool. Of 19,592 initial hits, 43 publications were included. Predominantly, retention of the prosthesis, retention loss of anchor crowns (decementations), fractures/repairs of frameworks, denture teeth, veneering or acrylic bases, and a need for relining were reported depending on prosthesis type and observation time. Focusing on technical complications and failures, only very heterogeneous data were found and publications with the highest quality level according to GRADE were scarce. Whenever possible, data on technical complications and failures should be reported separately when referencing the tooth, the prosthesis and the patient for comparability. Prostheses with differing anchorage types should be analyzed in different groups, as the respective complications and failures differ. A precise description of the kinds of complications and failures, as well as of the resulting follow-up treatment measures, should be given. Full article
Show Figures

Figure 1

12 pages, 1224 KB  
Article
Repair Bond Strength of Conventionally and Digitally Fabricated Denture Base Resins to Auto-Polymerized Acrylic Resin: Surface Treatment Effects In Vitro
by Mohammed M. Gad, Zainab Albazroun, Fatimah Aldajani, Ahmed M. Elakel, Mai El Zayat, Sultan Akhtar, Soban Q. Khan, Saqib Ali and Ahmed M. Rahoma
Materials 2022, 15(24), 9062; https://doi.org/10.3390/ma15249062 - 19 Dec 2022
Cited by 27 | Viewed by 4673
Abstract
Denture base fracture is one of the most annoying problems for both prosthodontists and patients. Denture repair is considered to be an appropriate solution rather than fabricating a new denture. Digital denture fabrication is widely spreading nowadays. However, the repair strength of CAD-CAM [...] Read more.
Denture base fracture is one of the most annoying problems for both prosthodontists and patients. Denture repair is considered to be an appropriate solution rather than fabricating a new denture. Digital denture fabrication is widely spreading nowadays. However, the repair strength of CAD-CAM milled and 3D-printed resins is lacking. This study aimed to evaluate the effect of surface treatment on the shear bond strength (SBS) of conventionally and digitally fabricated denture base resins. One l heat-polymerized (Major base20), two milled (IvoCad, AvaDent), and three 3D-printed (ASIGA, NextDent, FormLabs) denture base resins were used to fabricate 10 × 10 × 3.3 acrylic specimens (N = 180, 30/resin, n = 10). Specimens were divided into three groups according to surface treatment; no treatment (control), monomer application (MMA), or sandblasting (SB) surface treatments were performed. Repair resin was bonded to the resin surface followed by thermocycling (5000 cycles). SBS was tested using a universal testing machine where a load was applied at the resin interface (0.5 mm/min). Data were collected and analyzed using ANOVA and a post hoc Tukey test (α = 0.05). SEM was used for failure type and topography of fractured surfaces analysis. The heat-polymerized and CAD-CAM milled groups showed close SBS values without significance (p > 0.05), while the 3D-printed resin groups showed a significant decrease in SBS (p < 0.0001). SBS increased significantly with monomer application (p < 0.0001) except for the ASIGA and NextDent groups, which showed no significant difference compared to the control groups (p > 0.05). All materials with SB surface treatment showed a significant increase in SBS when compared with the controls and MMA application (p < 0.0001). Adhesive failure type was observed in the control groups, which dramatically changed to cohesive or mixed in groups with surface treatment. The SBS of 3D-printed resin was decreased when compared with the conventional and CAD-CAM milled resin. Regardless of the material type, SB and MMA applications increased the SBS of the repaired resin and SB showed high performance. Full article
(This article belongs to the Special Issue 3D Printed and CAD-CAM Milled Polymer-Based Materials for Dentistry)
Show Figures

Figure 1

15 pages, 1301 KB  
Review
The Use of Acrylate Polymers in Dentistry
by Milena Kostić, Marko Igić, Nikola Gligorijević, Vesna Nikolić, Nenad Stošić and Ljubiša Nikolić
Polymers 2022, 14(21), 4511; https://doi.org/10.3390/polym14214511 - 25 Oct 2022
Cited by 36 | Viewed by 8082
Abstract
The manuscript aimed to review the types of acrylate polymers used in dentistry, as well as their chemical, physical, mechanical, and biological properties. Regarding their consistency and purpose, dental acrylate polymers are divided into hard (brittle), which includes acrylates for the production of [...] Read more.
The manuscript aimed to review the types of acrylate polymers used in dentistry, as well as their chemical, physical, mechanical, and biological properties. Regarding their consistency and purpose, dental acrylate polymers are divided into hard (brittle), which includes acrylates for the production of plate denture bases, obturator prostheses, epitheses and maxillofacial prostheses, their repairs and lining, and soft (flexible), which are used for lining denture bases in special indications. Concerning the composition and method of polymerization initiation, polymers for the production of denture bases are divided into four types: heat-, cold-, light-, and microwave-polymerized. CAD/CAM acrylate dentures are made from factory blocks of dental acrylates and show optimal mechanical and physical properties, undoubtedly better monomer polymerization and thus biocompatibility, and stability of the shape and colour of the base and dentures. Regardless of the number of advantages that these polymers have to offer, they also exhibit certain disadvantages. Technological development enables the enhancement of all acrylate properties to respond better to the demands of the profession. Special attention should be paid to improving the biological characteristics of acrylate polymers, due to reported adverse reactions of patients and dental staff to potentially toxic substances released during their preparation and use. Full article
(This article belongs to the Special Issue Advanced Polymeric Materials for Pharmaceutical Applications III)
Show Figures

Figure 1

9 pages, 4417 KB  
Article
Influence of Incorporating 5% Weight Titanium Oxide Nanoparticles on Flexural Strength, Micro-Hardness, Surface Roughness and Water Sorption of Dental Self-Cured Acrylic Resin
by Rasha M. Abdelraouf, Rania E. Bayoumi and Tamer M. Hamdy
Polymers 2022, 14(18), 3767; https://doi.org/10.3390/polym14183767 - 8 Sep 2022
Cited by 27 | Viewed by 3358
Abstract
Background: Polymethyl methacrylate (PMMA) is used in fabricating acrylic denture bases. Repairing a fractured acrylic denture base can be done by self-cured PMMA, yet this is still a weak point after repair. The aim of this study was to evaluate the effect of [...] Read more.
Background: Polymethyl methacrylate (PMMA) is used in fabricating acrylic denture bases. Repairing a fractured acrylic denture base can be done by self-cured PMMA, yet this is still a weak point after repair. The aim of this study was to evaluate the effect of incorporating 5% weight titanium oxide nanoparticles (TiO2) to self-cured PMMA on flexural strength, surface micro-hardness, roughness, and water sorption. Methods: A total of 160 acrylic–resin specimens were used in this study. They were divided in two main groups; (a) control group, prepared by mixing self-cured PMMA powder to its liquid monomer, (b) treated group, prepared by blending 5% weight TiO2 nanoparticles to self-cured PMMA powder then this blend was mixed with the liquid monomer. Flexure strength, surface micro-hardness, roughness, and water sorption were evaluated. Data were analyzed using independent sample t-tests (p ≤ 0.05). Results: There was a significant increase in the flexural strength of PMMA of the treated group after the addition of TiO2 (137.6 MPa) compared with the control (75.4 MPa) (p ≤ 0.001). No significant difference between the two groups in terms of micro-hardness (p = 0.385) and surface roughness (p = 0.269). Water sorption showed a significant reduction in the treated group (p ≤ 0.001). Conclusions: Addition of 5% weight TiO2 nanoparticles to the self-cured acrylic resin improved its flexural strength and reduced its water-sorption without impairing the surface micro-hardness and roughness. Full article
Show Figures

Figure 1

11 pages, 6802 KB  
Article
Long-Term Prosthetic Aftercare of Mandibular Implant-Supported Overdenture
by Eran Zenziper, Ofir Rosner, Oded Ghelfan, Joseph Nissan, Sigalit Blumer, Gil Ben-Izhack, Hagay Slutzky, Isabelle Meinster, Liat Chaushu and Sarit Naishlos
Appl. Sci. 2022, 12(17), 8673; https://doi.org/10.3390/app12178673 - 29 Aug 2022
Cited by 1 | Viewed by 2341
Abstract
Background: Two of the most popular resilient attachment systems for mandibular implant-supported overdenture (MISOD) are locator and ball attachments. The purpose of the present retrospective cohort study was to assess the long-term prosthetic aftercare and oral hygiene status in edentulous patients rehabilitated with [...] Read more.
Background: Two of the most popular resilient attachment systems for mandibular implant-supported overdenture (MISOD) are locator and ball attachments. The purpose of the present retrospective cohort study was to assess the long-term prosthetic aftercare and oral hygiene status in edentulous patients rehabilitated with MISOD. Materials and Methods: Forty-five consecutive patients were included (22, group A- ball vs. 23, group B- locator attachments). Attachment incorporation into the MISOD was conducted in a direct (chair-side) intraoral technique at the time of denture insertion. Routine follow-up included yearly visits. The number of visits requiring prosthetic aftercare, either during the follow-up or during the additional visit, was recorded. Outcome parameters included—prosthetic aftercare—the number of aftercare (primary outcome parameter) visits, and dental treatment received (pressure sores relief, liner changes due to loss of retention, loss of retention due to debris accumulation, denture repair—secondary outcome parameters); oral hygiene—gingival index (primary outcome parameter). Results: The mean follow-up of the entire study population was 84 ± 21 months, range 39–120 months. Statistical analysis revealed a lower need for prosthetic aftercare interventions in group A (p < 0.001). The mean number of visits dedicated to pressure sores relief (6.09 ± 1.04 vs. 3.03 ± 0.77, p < 0.001) and liner exchange due to loss of retention (5.6 ± 1.03 vs. 2.09 ± 1.04, p < 0.001), were significantly lower in group A. Debris (food/calculus) accumulation inside the attachment was noted only for the locator’s group (p < 0.001). No statistically significant differences between the groups were noted for denture repair (p = 0.318). Oral hygiene also exhibited statistically significant differences in favor of group A (2.3 ± 0.3 vs. 1.03 ± 0.2, p < 0.001). Conclusions: It can be concluded that using ball attachments for MISOD yields less need for aftercare treatments and improved oral hygiene status over the years. Full article
(This article belongs to the Collection State-of-the-Art Dentistry and Oral Health)
Show Figures

Figure 1

10 pages, 2599 KB  
Article
Immediate versus Delayed Attachment Incorporation Impact on Prosthetic Aftercare among Mandibular Implant—Supported Overdenture Wearers
by Eran Zenziper, Ofir Rosner, Oded Ghelfan, Joseph Nissan, Sigalit Blumer, Gil Ben-Izhack, Moshe Davidovich, Liat Chaushu, Adrian Kahn and Sarit Naishlos
J. Clin. Med. 2022, 11(12), 3524; https://doi.org/10.3390/jcm11123524 - 19 Jun 2022
Cited by 1 | Viewed by 2364
Abstract
Background: Substantial effort is dedicated to finding the most favorable parameters that will ensure low aftercare demands among edentulous patients wearing mandibular implant supported overdentures (MISODs). The purpose of this retrospective cohort study was to compare prosthetic aftercare between MISOD patients with a [...] Read more.
Background: Substantial effort is dedicated to finding the most favorable parameters that will ensure low aftercare demands among edentulous patients wearing mandibular implant supported overdentures (MISODs). The purpose of this retrospective cohort study was to compare prosthetic aftercare between MISOD patients with a simultaneous (group A) vs. a three-week settling in period (group B) prior to attachment incorporation. Methods: Forty-five patients enrolled in this study. Two implants per patient were placed using a two-stage implant insertion protocol. Second-stage surgery was performed after three months. All patients received ball attachments using the direct (chairside) incorporation method. Twenty-two patients received their dentures with simultaneous attachment activation and the rest—twenty-three patients—after a three-week settling in period. Patients’ files were scanned for aftercare visits. Outcome parameters included sore spot relief, attachment incorporation, and denture repair. Additionally, gingival index measurements were compared. Confounding factors included age, gender, and implant dimensions. Results: The mean follow-up for the entire cohort was 84 ± 21 months, and the range 39–120 months. The mean number of visits for group A vs. B respectively: pressure sores relieve (3.63 ± 0.84 vs. 3.71 ± 0.61, p = 0.581), liner exchange due to loss of retention (2.09 ± 1.03 vs. 2.31 ± 1.04 p = 0.487), and gingival index (1.3 ± 0.3 vs. 1.03 ± 0.2, p = 0.653) exhibited no statistically significant differences between the tested groups. No statistically significant differences between the groups were also noted for the denture repair aftercare treatments (p = 0.318) and the independent variables including age, gender, and implant length. Conclusions: Prosthetic aftercare in MISOD wearers is similar whether a simultaneous or a three-week settling in period for attachment incorporation is applied. Full article
(This article belongs to the Topic State-of-the-Art Dentistry and Oral Health)
Show Figures

Figure 1

10 pages, 1571 KB  
Article
Implant-Retained Mandibular Overdentures: Patient-Related Outcome Measurements after Seven Years of Function
by Jan D'haese, Carine Matthys, Hamed Sahak, Jos Besseler and Hugo De Bruyn
Dent. J. 2022, 10(5), 88; https://doi.org/10.3390/dj10050088 - 16 May 2022
Cited by 3 | Viewed by 9745
Abstract
Denture wearers often complain about jeopardized function and reduced quality of life due to lack of prosthesis’ retention. Implant-retained mandibular overdentures, on two non-connected implants (2IOD) are well-proven solutions to overcome these issues. We prospectively assessed 69 patients and scrutinized clinical records until [...] Read more.
Denture wearers often complain about jeopardized function and reduced quality of life due to lack of prosthesis’ retention. Implant-retained mandibular overdentures, on two non-connected implants (2IOD) are well-proven solutions to overcome these issues. We prospectively assessed 69 patients and scrutinized clinical records until at least seven years of function. Thirty-six were retained on Locator® Abutments (LA) and thirty-tree on Ball Abutments (BA). Both systems were compared regarding the type, amount, and total cost of required maintenance. One implant was lost, yielding 98.7% survival after seven years. In total, 438 technical issues occurred: 121 (27.35%) in BA and 317 (72.4%) in LA. Out of these, 343 events (78%) were solved chairside: 191 (43.6%) were replacements of retention caps, 113 (25.8%) were minor acrylic repairs, 26 (5.9%) pressure ulcers had to be relieved, and 13 (3%) were related to abutments. LA required 179 insert replacements compared to 12 in the BA group. The overall initial treatment cost was EUR 3850 (base year of the analysis: 2003). The average total maintenance cost in relation to the initial cost for the LA and BA groups was 19.11 (range 0–82.24%) and 18.91% (range 0–113.26%) respectively (p = 0.540). Conclusions: The seven-year maintenance costs for a 2IOD is acceptable when the patient is regularly checked and professionally maintained. Most events are easily solvable chairside, but a few patients required more expensive interventions, regardless of the type of attachment used. Full article
(This article belongs to the Section Dental Implantology)
Show Figures

Figure 1

11 pages, 987 KB  
Article
Association of Dental and Prosthetic Status with Oral Health-Related Quality of Life in Centenarians
by Caroline Sekundo, Eva Langowski, Samuel Kilian, Diana Wolff, Andreas Zenthöfer and Cornelia Frese
Int. J. Environ. Res. Public Health 2021, 18(24), 13219; https://doi.org/10.3390/ijerph182413219 - 15 Dec 2021
Cited by 6 | Viewed by 2932
Abstract
To date, there is little evidence on centenarians’ dental and prosthetic status or their oral-health-related quality of life (OHRQoL). Therefore, the aim of this study was to assess possible associations between sociodemographic and oral health factors, including prosthetic needs in this special age [...] Read more.
To date, there is little evidence on centenarians’ dental and prosthetic status or their oral-health-related quality of life (OHRQoL). Therefore, the aim of this study was to assess possible associations between sociodemographic and oral health factors, including prosthetic needs in this special age group and their potential influence on OHRQoL. Persons born before 1920 were recruited from population registries in south-western Germany. Fifty-five centenarians participated and underwent a comprehensive oral examination. Cognitive capacity was evaluated using the short Mini-Mental State Examination (S-MMSE, max. 21 points). At an S-MMSE > 10, an analysis of OHRQoL by means of the Geriatric Oral Health Assessment Index (max. ADD-GOHAI score 60 points) was performed (n = 43). Bivariate statistics and a linear regression model were used after variable selection to analyze data. Centenarians presented with a mean (SD) of 22 (7.2) missing teeth. Complete (65.5%) or partial dentures (21.8%) in at least one jaw were most common. One-third of the dentures needed repair/replacement; 16% of the centenarians presented with denture sores. In 60% of cases, OHRQoL was rated unsatisfactory (ADD-GOHAI < 57). Trouble biting or chewing resulted in the lowest levels of OHRQoL. Fewer remaining teeth, reduced functional capacity and removable prostheses correlated with an impaired OHRQoL (rs = −0.36, p = 0.01; rs = −0.34, p = 0.01; rs = −0.29, p = 0.03, respectively). After variable selection, the final linear regression model included only the number of missing teeth, the associated ADD-GOHAI score decreasing by 0.3 points per missing tooth. In conclusion, tooth loss and removable prostheses in need of repair or replacement are highly prevalent in centenarians. These factors seem to modulate OHRQoL negatively, assumedly due to impaired chewing function. Larger confirmatory studies are needed to validate these first results. Full article
(This article belongs to the Special Issue Oral Health — Prevention, Diagnostics, Therapy and Quality of Life)
Show Figures

Figure 1

12 pages, 1553 KB  
Article
Dentists’ Working Conditions during the First COVID-19 Pandemic Lockdown: An Online Survey
by Vera Wiesmüller, Emanuel Bruckmoser, Ines Kapferer-Seebacher, Katharina Fink, Sabrina Neururer, Dagmar Schnabl and Johannes Laimer
Healthcare 2021, 9(3), 364; https://doi.org/10.3390/healthcare9030364 - 23 Mar 2021
Cited by 11 | Viewed by 3930
Abstract
The aim of this study was to investigate the operating conditions of dentists in Central Europe during the first coronavirus disease 2019 (COVID-19) lockdown. A survey including 24 questions was emailed to dentists in Austria, Germany, Switzerland and South Tyrol (Italy). Questions regarding [...] Read more.
The aim of this study was to investigate the operating conditions of dentists in Central Europe during the first coronavirus disease 2019 (COVID-19) lockdown. A survey including 24 questions was emailed to dentists in Austria, Germany, Switzerland and South Tyrol (Italy). Questions regarding dentists’ field of work, working hours, treatments performed, personal protective equipment and protocols, and economic consequences were asked. 1731 participants were included. 30.4% of participants worked mainly in Austria, 60.8% in Germany, 6% in Switzerland and 2.1% in South Tyrol. A country-specific analysis for the situation of South Tyrol was not possible due to the low participation; 53.7% of German, 45.5% of Austrian, and 11.7% of Swiss respondents reduced their working hours; 42.8% of Austrian, 41.5% of Swiss, and 17.3% of German participants closed their offices temporarily; 52.2% of respondents provided emergency service including pain management, restorations/temporaries, and denture repairs. A lack of access to FFP2/FFP3 (filtering facepiece) respirators was indicated by 59.4% Austrian, 38.0% German, and 11.7% Swiss dentists (p < 0.001). FFP2/FFP3 respirators were, when available, most frequently used in Austria (86.9%), followed by Switzerland (61.2%) and Germany (56.7%) (p < 0.001). Financial consequences could not be conclusively quantified by 58.6% of the participants. Most respondents in all partaking countries made use of governmental support. A lack of blueprints/guidelines resulted in heterogeneous working conditions. In consideration of a potentially high risk of infection in the dental setting, non-emergency dental treatments were largely suspended in all participating countries. Full article
(This article belongs to the Collection Healthcare in Dentistry)
Show Figures

Figure 1

35 pages, 3461 KB  
Review
Prosthodontic Applications of Polymethyl Methacrylate (PMMA): An Update
by Muhammad Sohail Zafar
Polymers 2020, 12(10), 2299; https://doi.org/10.3390/polym12102299 - 8 Oct 2020
Cited by 551 | Viewed by 48207
Abstract
A wide range of polymers are commonly used for various applications in prosthodontics. Polymethyl methacrylate (PMMA) is commonly used for prosthetic dental applications, including the fabrication of artificial teeth, denture bases, dentures, obturators, orthodontic retainers, temporary or provisional crowns, and for the repair [...] Read more.
A wide range of polymers are commonly used for various applications in prosthodontics. Polymethyl methacrylate (PMMA) is commonly used for prosthetic dental applications, including the fabrication of artificial teeth, denture bases, dentures, obturators, orthodontic retainers, temporary or provisional crowns, and for the repair of dental prostheses. Additional dental applications of PMMA include occlusal splints, printed or milled casts, dies for treatment planning, and the embedding of tooth specimens for research purposes. The unique properties of PMMA, such as its low density, aesthetics, cost-effectiveness, ease of manipulation, and tailorable physical and mechanical properties, make it a suitable and popular biomaterial for these dental applications. To further improve the properties (thermal properties, water sorption, solubility, impact strength, flexural strength) of PMMA, several chemical modifications and mechanical reinforcement techniques using various types of fibers, nanoparticles, and nanotubes have been reported recently. The present article comprehensively reviews various aspects and properties of PMMA biomaterials, mainly for prosthodontic applications. In addition, recent updates and modifications to enhance the physical and mechanical properties of PMMA are also discussed. Full article
(This article belongs to the Special Issue Polymers for Dental Restorative and Oral Tissue Engineering)
Show Figures

Graphical abstract

9 pages, 913 KB  
Article
Influence of Different Repair Acrylic Resin and Thermocycling on the Flexural Strength of Denture Base Resin
by Mohammed AlQahtani and Satheesh B. Haralur
Medicina 2020, 56(2), 50; https://doi.org/10.3390/medicina56020050 - 21 Jan 2020
Cited by 29 | Viewed by 6121
Abstract
Background and Objectives: Fractured acrylic denture base is a common occurrence in clinical practice. The effective denture repair procedure is cost-effective, time conserving, and results in lesser time without denture for the patient. Along with various reinforcements and surface modifications; different acrylic resins [...] Read more.
Background and Objectives: Fractured acrylic denture base is a common occurrence in clinical practice. The effective denture repair procedure is cost-effective, time conserving, and results in lesser time without denture for the patient. Along with various reinforcements and surface modifications; different acrylic resins are investigated in improving the flexural strength of the fractured site. The aim of this study was to evaluate the flexural strength of a polymethyl methacrylate (PMMA) denture base repaired with heat-polymerized (HPA), auto-polymerized (APA) and light-polymerized acrylic (LPA) resins after thermocycling. Materials and Methods: Forty rectangular shaped (50 mm × 25 mm × 3 mm) PMMA specimens were fabricated. Group 1 specimens (n = 10) were kept as controls and the remaining 30 samples were sectioned at the center with a repair site dimension of 3 mm. The samples from three groups (n = 10) were repaired with HPA, APA, and LPA resins, respectively. The specimens were thermocycled for 5000 cycles and subjected to a three-point flexural test. The maximum load required to fracture the specimens was recorded, and further analyzed with ANOVA and the Games-Howell Post hoc test at the significance level p = 0.05. Results: The average maximum load and flexural strength of the control group was 173.60 N and 13.02 Mpa and corresponding values for denture repaired with HPA was 87.36 N and 6.55 Mpa. The corresponding values for APA resin and LPA resins were 62.94 N, 57.51 N, and 4.72 Mpa, 4.06 Mpa, respectively. Conclusions: The PMMA specimens repaired with HPA resins resulted in a significantly higher load to fracture compared to APA resin and LPA resin. Full article
(This article belongs to the Special Issue Oral Health: Economic and Psychological–Behavioral Implications)
Show Figures

Figure 1

Back to TopTop