Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (25)

Search Parameters:
Keywords = balloon valvuloplasty

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
26 pages, 2260 KiB  
Review
Transcatheter Aortic Valve Implantation in Cardiogenic Shock: Current Evidence, Clinical Challenges, and Future Directions
by Grigoris V. Karamasis, Christos Kourek, Dimitrios Alexopoulos and John Parissis
J. Clin. Med. 2025, 14(15), 5398; https://doi.org/10.3390/jcm14155398 (registering DOI) - 31 Jul 2025
Abstract
Cardiogenic shock (CS) in the setting of severe aortic stenosis (AS) presents a critical and high-risk scenario with limited therapeutic options and poor prognosis. Transcatheter aortic valve implantation (TAVI), initially reserved for inoperable or high-risk surgical candidates, is increasingly being considered in patients [...] Read more.
Cardiogenic shock (CS) in the setting of severe aortic stenosis (AS) presents a critical and high-risk scenario with limited therapeutic options and poor prognosis. Transcatheter aortic valve implantation (TAVI), initially reserved for inoperable or high-risk surgical candidates, is increasingly being considered in patients with CS due to improvements in device technology, operator experience, and supportive care. This review synthesizes current evidence from large registries, observational studies, and meta-analyses that support the feasibility, safety, and potential survival benefit of urgent or emergent TAVI in selected CS patients. Procedural success is high, and early intervention appears to confer improved short-term and mid-term outcomes compared to balloon aortic valvuloplasty or medical therapy alone. Critical factors influencing prognosis include lactate levels, left ventricular ejection fraction, renal function, and timing of intervention. The absence of formal guidelines, logistical constraints, and ethical concerns complicate decision-making in this unstable population. A multidisciplinary Heart Team/Shock Team approach is essential to identify appropriate candidates, manage procedural risk, and guide post-intervention care. Further studies and the development of TAVI-specific risk models in CS are anticipated to refine patient selection and therapeutic strategies. TAVI may represent a transformative option for stabilizing hemodynamics and improving outcomes in this otherwise high-mortality group. Full article
(This article belongs to the Special Issue Aortic Valve Implantation: Recent Advances and Future Prospects)
Show Figures

Figure 1

13 pages, 1345 KiB  
Article
Performance of the Mammoth Balloon Catheter in Patients with Severe Aortic Valve Stenosis Undergoing Percutaneous Treatment
by Silvia Moscardelli, Rodolfo Caminiti, Carolina Montonati, Fabrizio Ceresa, Giuseppe De Blasio, Giampiero Vizzari, Dario Pellegrini, Mariano Pellicano, Giulio Guagliumi, Francesco Patanè, Maurizio Tespili, Antonio Micari and Alfonso Ielasi
J. Clin. Med. 2024, 13(19), 5986; https://doi.org/10.3390/jcm13195986 - 8 Oct 2024
Cited by 1 | Viewed by 1791
Abstract
Background: Balloon aortic valvuloplasty (BAV) is currently used as pre-treatment for patients undergoing trans-catheter aortic valve replacement (TAVR) as well as a stand-alone option for subjects with significant contraindications to TAVR. Mammoth is a newly available non-compliant balloon catheter (BC) included in [...] Read more.
Background: Balloon aortic valvuloplasty (BAV) is currently used as pre-treatment for patients undergoing trans-catheter aortic valve replacement (TAVR) as well as a stand-alone option for subjects with significant contraindications to TAVR. Mammoth is a newly available non-compliant balloon catheter (BC) included in the balloon-expandable Myval THV system (Meril Life Sciences Pvt. Ltd., India). As limited data on the performance of this BC are available, we here report the results following its use for BAV as pre-dilatation during TAVR or as a stand-alone procedure. Methods: A retrospective, single-center cohort analysis was performed on patients with severe aortic valve stenosis (AS) treated with the Mammoth BC at IRCCS Ospedale Galeazzi Sant’Ambrogio, Milan, Italy. The primary endpoint was technical success defined as successful Mammoth BC advancement across the AS followed by its full and homogeneous inflation without major complications such as aortic root/left ventricular outflow tract injury and/or stroke. Results: A total of 121 patients were treated by BAV with Mammoth BC during the study period. Among these, 105 patients underwent BAV pre-dilatation before TAVR while 16 patients underwent a stand-alone BAV procedure. Mammoth BC was delivered and successfully inflated at the target site in all of the 121 cases without BC-related complications (100% technical success). However, in the BAV “stand-alone group”, three patients required two different balloon sizes while in nine patients multiple rounds (two to three) of balloon inflation were needed to significantly lower the transvalvular gradient. No cases of aortic root injury or massive aortic regurgitation due to Mammoth BC-related aortic leaflet injury were reported while one major stroke occurred late after TAVR. No intra-procedural deaths occurred nor bleeding (BARC 3-4) or major vascular complication. Conclusions: Mammoth BC use in patients with severe AS proved safe and effective, either before TAVR or as a stand-alone procedure, expanding the range of available tools for structural operators. Full article
(This article belongs to the Section Cardiology)
Show Figures

Figure 1

10 pages, 633 KiB  
Article
Influence of Right Atrial Pressure on the Prognosis of Patients with Rheumatic Mitral Stenosis Undergoing Percutaneous Mitral Balloon Valvuloplasty
by Daniella Cian Nazzetta, Larissa Christine Gomes de Sousa, Vitor Emer Egypto Rosa, Fernanda Castiglioni Tessari, Carlos M. Campos, Maria Antonieta Albanez Medeiros Lopes, Carlos Viana Poyares Jardim, Luís Gustavo Mapa, Layara Fernanda Vicente Pereira Lipari, Mariana Pezzute Lopes, João Ricardo Cordeiro Fernandes, Antonio de Santis, Lucas José Neves Tachotti Pires, Roney Orismar Sampaio and Flávio Tarasoutchi
Diagnostics 2024, 14(18), 2079; https://doi.org/10.3390/diagnostics14182079 - 19 Sep 2024
Viewed by 1114
Abstract
Background: Pulmonary hypertension (PH) often complicates mitral stenosis (MS). The prognostic impact of pulmonary vascular resistance (PVR) in MS patients remains unclear. Previous study has demonstrated the prognostic impact of right atrial pressure (RAP) in patients with primary PH. We aim to determine [...] Read more.
Background: Pulmonary hypertension (PH) often complicates mitral stenosis (MS). The prognostic impact of pulmonary vascular resistance (PVR) in MS patients remains unclear. Previous study has demonstrated the prognostic impact of right atrial pressure (RAP) in patients with primary PH. We aim to determine the prognostic impact of PVR and RAP in patients with rheumatic MS undergoing percutaneous mitral balloon valvuloplasty (PMBV). Methods: A total of 58 patients with symptomatic severe rheumatic MS who underwent PMBV between 2016 and 2020 were included. Patients were divided into two groups: PVR ≤ 2WU (N = 26) and PVR > 2WU (N = 32). The composite endpoint included death, reintervention or persistent NYHA functional class III-IV during follow-up. Results: The median age was 50 (42–60) years, with 82.8% being female. Median pulmonary artery systolic pressure (PASP) was 42 (35–50.5) mmHg. Patients with PVR ≤ 2WU had lower PASP on both echocardiogram and catheterization. The PMBV success rate was 75.9%. Multivariate analysis, adjusted for PVR, showed RAP as the only independent predictor of the composite endpoint (HR:1.507, 95% CI:1.015–2.237, p = 0.042). The optimal RAP cutoff was 9.5 mmHg (HR:3.481, 95% CI:1.041–11.641; p = 0.043). Conclusions: RAP was an independent predictor of adverse outcomes in patients with rheumatic MS undergoing PMBV, while PVR did not show prognostic significance. These findings suggest that the prognostic value of PVR may be lower than expected. Full article
(This article belongs to the Special Issue Rheumatic Diseases: Diagnosis and Management)
Show Figures

Figure 1

13 pages, 1209 KiB  
Article
Self-Reported Management of Incidentally Detected Heart Murmurs in Puppies: A Survey among Veterinarians
by Marie D. B. van Staveren, Esther Muis and Viktor Szatmári
Animals 2024, 14(12), 1821; https://doi.org/10.3390/ani14121821 - 19 Jun 2024
Viewed by 1291
Abstract
Background: Heart murmurs in puppies can be innocent or pathologic; the latter is almost always related to a congenital heart disease. Differentiating between these murmurs can be challenging for practicing veterinarians, but this differentiation is essential to ensure the best prognosis for puppies [...] Read more.
Background: Heart murmurs in puppies can be innocent or pathologic; the latter is almost always related to a congenital heart disease. Differentiating between these murmurs can be challenging for practicing veterinarians, but this differentiation is essential to ensure the best prognosis for puppies having a congenital heart disease. Our study aimed to reveal how veterinarians manage puppies with a heart murmur. Methods: A web-based questionnaire was sent to Dutch and Belgian veterinary practices. Results: Data from 452 respondents were analyzed. Though 88% of the respondents find detecting a heart murmur easy, only 9% find differentiating innocent murmurs from pathologic murmurs in puppies easy. Of the respondents, only 80% recommend immediate additional examination when detecting a loud heart murmur during the first veterinary health check at 6 weeks of age. Most of the respondents are aware that normal growth and the absence of clinical signs do not exclude severe congenital heart disease. Of the respondents, 31% were uncertain whether early surgical intervention could lead to improved outcomes. Conclusions: Veterinarians are aware of the importance of echocardiography for puppies with a loud heart murmur, and recognize their limitations when differentiating an innocent from a pathological heart murmur in a puppy. Full article
(This article belongs to the Section Companion Animals)
Show Figures

Figure 1

14 pages, 10162 KiB  
Article
Instant Detection of Cerebral Blood Flow Changes in Infants with Congenital Heart Disease during Transcatheter Interventions
by Martin Leth-Olsen, Gaute Døhlen, Hans Torp and Siri Ann Nyrnes
J. Clin. Med. 2024, 13(11), 3115; https://doi.org/10.3390/jcm13113115 - 26 May 2024
Viewed by 1222
Abstract
Background: Transcatheter interventions are increasingly used in children with congenital heart disease. However, these interventions can affect cardiac output and cerebral circulation. In this pilot study, we aimed to investigate the use of NeoDoppler, a continuous transfontanellar cerebral Doppler monitoring system, to [...] Read more.
Background: Transcatheter interventions are increasingly used in children with congenital heart disease. However, these interventions can affect cardiac output and cerebral circulation. In this pilot study, we aimed to investigate the use of NeoDoppler, a continuous transfontanellar cerebral Doppler monitoring system, to evaluate the impact of transcatheter interventions on cerebral circulation. Methods: Nineteen participants under one year of age (mean age 3.5 months) undergoing transcatheter cardiac interventions were prospectively included. Transfontanellar cerebral Doppler monitoring with the NeoDoppler system was initiated after intubation and continued until the end of the procedure. Results: Instant detection of changes in cerebral blood flow were observed across a spectrum of transcatheter interventions. Balloon aortic valvuloplasty demonstrated temporary cessation of cerebral blood flow during balloon inflation. Increase in cerebral diastolic blood flow velocity and decreased pulsatility were observed during patent ductus arteriosus occlusion. Changes in cerebral blood flow patterns were detected in two patients who encountered complications during their transcatheter interventions. There was no significant change in Doppler parameters before and after the interventions for the entire patient group. High quality recordings were achieved in 87.3% of the monitoring period. Conclusions: Continuous transfontanellar cerebral Doppler is feasible in monitoring cerebral hemodynamic trends and shows instantaneous changes associated with interventions and complications. It could become a useful monitoring tool during transcatheter interventions in infants. Full article
Show Figures

Figure 1

14 pages, 4094 KiB  
Article
Balloon Valvuloplasty in Congenital Critical Aortic Valve Stenosis in Neonates and Infants: A Rescue Procedure for the Left Ventricle
by Jochen Pfeifer, Axel Rentzsch, Martin Poryo and Hashim Abdul-Khaliq
J. Cardiovasc. Dev. Dis. 2024, 11(5), 156; https://doi.org/10.3390/jcdd11050156 - 18 May 2024
Cited by 2 | Viewed by 2187
Abstract
Congenital critical aortic valve stenosis (CAVS) is a life-threatening disease requiring urgent treatment. First-line therapy is still controversial. The aim of our study was (1) to analyze retrospectively the patients of our institution who underwent balloon aortic valvuloplasty (BAV) due to CAVS and [...] Read more.
Congenital critical aortic valve stenosis (CAVS) is a life-threatening disease requiring urgent treatment. First-line therapy is still controversial. The aim of our study was (1) to analyze retrospectively the patients of our institution who underwent balloon aortic valvuloplasty (BAV) due to CAVS and (2) describe the techniques for improved feasibility of intervention using microcatheters and retrieval loops. Twelve patients underwent 23 BAVs: 1 BAV was performed in 3 patients, 2 BAVs were performed in 7 patients, and 3 BAVs were performed in 2 patients. The peak trans-valvular pressure gradient (Δp) and left ventricular shortening fraction (LVSF) improved significantly in the first two interventions. In the first BAV, Δp decreased from 73.7 ± 34.5 mmHg to 39.8 ± 11.9 mmHg (p = 0.003), and the LVSF improved from 22.3 ± 13.5% to 31.6 ± 10.2% (p = 0.001). In the second BAV, Δp decreased from 73.2 ± 33.3 mmHg to 35.0 ± 20.2 mmHg (p < 0.001), and the LVSF increased from 26.7 ± 9.6% to 33.3 ± 7.4% (p = 0.004). Cardiac surgery during the neonatal period was avoided for all children. The median time to valve surgery was 5.75 years. Few complications occurred, namely mild-to-moderate aortic regurgitation, one remediable air embolism, and one intimal injury to the ascending aorta. We conclude that BAV is a successful emergency treatment for CAVS, resulting in left ventricular relief, clinical stabilization, and a time gain until cardiac surgery. Full article
(This article belongs to the Special Issue Heart Diseases in Children)
Show Figures

Graphical abstract

12 pages, 766 KiB  
Review
Aortic Valve Stenosis and Cancer: Problems of Management
by Gloria Santangelo, Silvia Moscardelli, Lucia Barbieri, Andrea Faggiano, Stefano Carugo and Pompilio Faggiano
J. Clin. Med. 2023, 12(18), 5804; https://doi.org/10.3390/jcm12185804 - 6 Sep 2023
Cited by 6 | Viewed by 2346
Abstract
Aortic valve stenosis and malignancy frequently coexist and share the same risk factors as atherosclerotic disease. Data reporting the prognosis of patients with severe aortic stenosis and cancer are limited. Tailoring the correct and optimal care for cancer patients with severe aortic stenosis [...] Read more.
Aortic valve stenosis and malignancy frequently coexist and share the same risk factors as atherosclerotic disease. Data reporting the prognosis of patients with severe aortic stenosis and cancer are limited. Tailoring the correct and optimal care for cancer patients with severe aortic stenosis is complex. Cancer patients may be further disadvantaged by aortic stenosis if it interferes with their treatment by increasing the risk associated with oncologic surgery and compounding the risks associated with cardiotoxicity and heart failure (HF). Surgical valve replacement, transcatheter valve implantation, balloon valvuloplasty, and medical therapy are possible treatments for aortic valve stenosis, but when malignancy is present, the choice between these options must take into account the stage of cancer and associated treatment, expected outcome, and comorbidities. Physical examination and Doppler echocardiography are critical in the diagnosis and evaluation of aortic stenosis. The current review considers the available data on the association between aortic stenosis and cancer and the therapeutic options. Full article
(This article belongs to the Special Issue Valvular Heart Disease: From Basic to Clinical Advances)
Show Figures

Figure 1

8 pages, 1961 KiB  
Case Report
Intracoronary Pacing during “Chimney Technique” in Transcatheter Aortic Valve-in-Valve Implantation: An Alternative Temporary Rapid Ventricular Stimulation?
by Alessandro Cafaro, Francesco Rizzo, Dionigi Fischetti, Luca Quarta, Marco Mussardo, Alessandro Mandurino-Mirizzi, Antonio Tondo, Marco Matteo Ciccone, Fortunato Iacovelli and Giuseppe Colonna
J. Cardiovasc. Dev. Dis. 2023, 10(8), 341; https://doi.org/10.3390/jcdd10080341 - 8 Aug 2023
Viewed by 1903
Abstract
Temporary rapid ventricular pacing (TRVP) is required during transcatheter aortic valve implantation (TAVI) in order to reduce cardiac output and to facilitate balloon aortic valvuloplasty, prosthesis deployment, and post-deployment balloon dilation. The two most frequently used TRVP techniques are right endocardial (RE)-TRVP and [...] Read more.
Temporary rapid ventricular pacing (TRVP) is required during transcatheter aortic valve implantation (TAVI) in order to reduce cardiac output and to facilitate balloon aortic valvuloplasty, prosthesis deployment, and post-deployment balloon dilation. The two most frequently used TRVP techniques are right endocardial (RE)-TRVP and retrograde left endocardial temporary rapid ventricular pacing (RLE)-TRVP. The first one could be responsible for cardiac tamponade, one of the most serious procedural complications during TAVI, while the second one could often be unsuccessful. Intracoronary (IC)-TRVP through a coronary guidewire has been described as a safe and efficient procedure that could avoid such complications. We describe two clinical cases in which IC-TRVP has been effectively used during valve-in-valve TAVI with coronary protection via the “chimney technique”, after unsuccessful RLE-TRVP. Full article
(This article belongs to the Special Issue Aortic Stenosis: Diagnosis, Treatment and Management)
Show Figures

Figure 1

11 pages, 429 KiB  
Article
Long-Term Postnatal Follow-Up in Monochorionic TTTS Twin Pregnancies Treated with Fetoscopic Laser Surgery and Complicated by Right Ventricular Outflow Tract Anomalies
by Stefano Faiola, Maria Mandalari, Chiara Coco, Daniela Casati, Arianna Laoreti, Savina Mannarino, Carla Corti, Dario Consonni, Irene Cetin and Mariano Lanna
J. Clin. Med. 2023, 12(14), 4734; https://doi.org/10.3390/jcm12144734 - 17 Jul 2023
Cited by 1 | Viewed by 1777
Abstract
Right ventricular outflow tract anomalies (RVOTAs), such as pulmonary stenosis (PS), pulmonary atresia (PA), and pulmonary insufficiency (PI), are typical cardiac anomalies in monochorionic twins, and they are complicated by twin-to-twin transfusion syndrome (TTTS). The aim of this study was to conduct a [...] Read more.
Right ventricular outflow tract anomalies (RVOTAs), such as pulmonary stenosis (PS), pulmonary atresia (PA), and pulmonary insufficiency (PI), are typical cardiac anomalies in monochorionic twins, and they are complicated by twin-to-twin transfusion syndrome (TTTS). The aim of this study was to conduct a long-term postnatal cardiological evaluation of prenatal RVOTAs in monochorionic diamniotic twin pregnancies complicated by TTTS and treated with fetoscopic laser surgery (FLS) and to analyze possible prenatal predictors of congenital heart disease (CHD). Prenatal RVOTAs were retrospectively retrieved from all TTTS cases treated with FLS in our unit between 2009 and 2019. Twenty-eight prenatal cases of RVOTAs (16 PI, 10 PS, 2 PA) were observed out of 335 cases of TTTS. Four cases did not reach the postnatal period. CHD was present in 17 of the remaining 24 cases (70.8%), with 10 being severe (58.8%; 10/17); nine cases of PS required balloon valvuloplasty, and one case required biventricular non-compaction cardiomyopathy. The risk of major CHD increased with prenatal evidence of PS and decreased with the gestational age at the time of TTTS and with the prenatal normalization of blood flow across the pulmonary valve. Despite treatment with FLS, the majority of monochorionic diamniotic twin pregnancies complicated by TTTS with prenatal RVOTAs had CHD at long-term follow-up. Full article
(This article belongs to the Special Issue Clinical Diagnosis and Management of Pregnancy Complications)
Show Figures

Graphical abstract

31 pages, 28195 KiB  
Review
Balloon Dilatation in the Management of Congenital Obstructive Lesions of the Heart: Review of Author’s Experiences and Observations—Part II
by P. Syamasundar Rao
J. Cardiovasc. Dev. Dis. 2023, 10(7), 288; https://doi.org/10.3390/jcdd10070288 - 6 Jul 2023
Cited by 2 | Viewed by 1801
Abstract
While investigating the outcomes of balloon dilatation procedures in patients with congenital obstructive lesions of the heart, several parallel observations were made. The purpose of this review is to present these observations/phenomena/innovations related to balloon dilatation of pulmonary stenosis (PS), aortic stenosis (AS), [...] Read more.
While investigating the outcomes of balloon dilatation procedures in patients with congenital obstructive lesions of the heart, several parallel observations were made. The purpose of this review is to present these observations/phenomena/innovations related to balloon dilatation of pulmonary stenosis (PS), aortic stenosis (AS), and aortic coarctation (AC). In subjects who had balloon pulmonary valvuloplasty (BPV), development of infundibular obstruction, electrocardiographic (ECG) changes, changes in right ventricular filling, role of balloon/annulus ratios on the results of BPV, and double balloon vs. single balloon BPV will be reviewed. In patients who had balloon aortic valvuloplasty (BAV), causes of aortic insufficiency and trans-umbilical venous approach for BAV are tackled. In children who had balloon angioplasty (BA) of AC, aortic remodeling and biophysical response after BA of AC are discussed. Full article
Show Figures

Figure 1

10 pages, 1972 KiB  
Article
Acute Changes in Right Ventricular Function in Pediatric Patients with Pulmonary Valve Stenosis Undergoing Percutaneous Valvuloplasty: A Speckle-Tracking Study
by Domenico Sirico, Giulia Spigariol, Heba Talat Mahmoud, Alessia Basso, Elena Cuppini, Martina Avesani, Jolanda Sabatino, Biagio Castaldi and Giovanni Di Salvo
J. Clin. Med. 2023, 12(13), 4344; https://doi.org/10.3390/jcm12134344 - 28 Jun 2023
Cited by 3 | Viewed by 1508
Abstract
Introduction: Pulmonary valve stenosis determines multiple effects on the right ventricular dimension and function. Percutaneous balloon valvuloplasty is the treatment of choice in severe pulmonary valve stenosis in patients of all ages. However, little is known regarding right ventricular function immediate changes after [...] Read more.
Introduction: Pulmonary valve stenosis determines multiple effects on the right ventricular dimension and function. Percutaneous balloon valvuloplasty is the treatment of choice in severe pulmonary valve stenosis in patients of all ages. However, little is known regarding right ventricular function immediate changes after percutaneous balloon dilation. Pediatric patients with isolated pulmonary valve stenosis represent a pure clinical model of chronic RV pressure overload not affected by other confounders or comorbidities. Aim of the study: This study seeks to explore right ventricle (RV) mechanics in pediatric patients early after percutaneous balloon pulmonary valvuloplasty (BPV) for valvar pulmonary stenosis (PS). Materials and Methods: Forty-three pediatric patients (19 males), mean age 3.2 ± 4.9 years old, with severe pulmonary valve stenosis and indication for percutaneous balloon valvuloplasty were recruited. All patients underwent standard transthoracic echocardiography (TTE), and speckle-tracking echocardiography (STE) with an analysis of right ventricle free-wall longitudinal strain (RVFWLS) one day before and one day after the procedure. For each patient, we collected invasive parameters during the interventional procedure before and after BPV. Results: After the procedure, there was an immediate significant reduction in both peak-to-peak transpulmonary gradient (peak-to-peak PG) and ratio between the right ventricle and aortic systolic pressure (RV/AoP) with a drop of ∆29.3 ± 14.67 mmHg and ∆0.43 ± 0.03, respectively. Post-procedural echocardiography showed peak and mean transvalvar pressure gradient drop (∆50 ± 32.23 and ∆31 ± 17.97, respectively). The degree of pulmonary valve regurgitation was mild in 8% of patients before the procedure, affecting 29% of our patients post-BPV (p = 0.007). The analysis of right ventricular mechanics showed a significant improvement of fractional area change (FAC) immediately after BPV (40.11% vs. 44.42%, p = 0.01). On the other hand, right ventricular longitudinal systolic function parameters, TAPSE and global RVFWLS, did not improve significantly after intervention. The segmental analysis of the RVFWLS showed a significant regional increase in the myocardial deformation of the apical segments. Conclusions: Percutaneous BPV represents an efficient and safe procedure to relieve severe pulmonary valve stenosis. The analysis of the right ventricular function on echocardiography demonstrated an immediate global systolic function improvement, while longitudinal systolic function was persistently impaired 24 h after intervention, possibly due to the necessity of a longer recovery time. Full article
(This article belongs to the Special Issue Management of Pediatric Congenital Heart Disease)
Show Figures

Figure 1

10 pages, 1739 KiB  
Case Report
Contrast-Associated Acute Kidney Injury Requiring Continuous Renal Replacement Therapy in A Neonate with Aortic Stenosis—A Case Report
by Catalin Cirstoveanu, Carmina Georgescu, Nicolae Ruxandra, Mihaela Bizubac, Eliza Cinteza, Corina Maria Vasile, Cristina Filip and Irina Margarint
Pediatr. Rep. 2023, 15(2), 323-332; https://doi.org/10.3390/pediatric15020028 - 22 May 2023
Cited by 2 | Viewed by 3337
Abstract
Background: Acute kidney injury occurs commonly in the Neonatal Intensive Care Unit and is associated with increased mortality and morbidity. We report a case of a neonate with congenital heart disease who developed acute kidney injury after cardiac surgery, administration of iodinated contrast [...] Read more.
Background: Acute kidney injury occurs commonly in the Neonatal Intensive Care Unit and is associated with increased mortality and morbidity. We report a case of a neonate with congenital heart disease who developed acute kidney injury after cardiac surgery, administration of iodinated contrast media for cardiac catheterization, and a combination of nephrotoxic drugs. Case report: A term neonate without a prenatal diagnosis of congenital heart disease and with a good postnatal transition was transferred at 13 days of life to the MS Curie Emergency Hospital for Children, Newborn Intensive Care Unit, from a regional hospital where he was admitted at 10 days of life with severe general status, respiratory distress, cyanosis, and arterial hypotension. The cardiac ultrasound detected critical aortic valve stenosis, hypoplastic descending aorta, acute heart failure, and pulmonary hypertension. The patient was intubated and mechanically ventilated and received antibiotherapy (meropenem, vancomycin, and colistin), inotropic and vasoactive support (epinephrine, norepinephrine, dopamine, and milrinone), and diuretic support (furosemide, aminophylline, and ethacrynic acid). A balloon aortic valvuloplasty was performed several hours after admission, but after two days the patient required reintervention by open heart surgery due to relapsing severe aortic stenosis. He developed oligo-anuria, generalized edema, and altered renal function tests on the second postoperative and fourth day post-contrast media administration. Continuous renal replacement therapy was initiated for 75 h, leading to almost instant improvement in blood pressure, then diuresis and creatinine levels. The patient required long-term treatment for heart, respiratory, and liver failure. He was discharged at almost four months of age with normal renal function tests, blood pressure, and good urine output without diuretic support. The literature review indicates that contrast-associated acute kidney injury (CA-AKI) requiring continuous renal replacement therapy is rare. Conclusions: Our current case proves that iodinated contrast media administration in a neonate with concomitant insults, such as cardiac surgery for a specific pathology, aortic stenosis, coarctation, arch stenosis, arterial hypotension, and administration of nephrotoxic drugs, may lead to severe kidney injury. Full article
Show Figures

Figure 1

12 pages, 1027 KiB  
Article
The Positive Impact of Early Frailty Levels on Mortality in Elderly Patients with Severe Aortic Stenosis Undergoing Transcatheter/Surgical Aortic Valve Replacement
by Annamaria Mazzone, Serena Del Turco, Giuseppe Trianni, Paola Quadrelli, Marco Marotta, Luca Bastiani, Tommaso Gasbarri, Andreina D’Agostino, Massimiliano Mariani, Giuseppina Basta, Ilenia Foffa, Silverio Sbrana, Cristina Vassalle, Marcello Ravani, Marco Solinas and Sergio Berti
J. Cardiovasc. Dev. Dis. 2023, 10(5), 212; https://doi.org/10.3390/jcdd10050212 - 13 May 2023
Cited by 4 | Viewed by 2116
Abstract
Background: Frailty is highly common in older patients (pts) undergoing transcatheter aortic valve replacement (TAVR), and it is associated with poor outcomes. The selection of patients who can benefit from this procedure is necessary and challenging. The aim of the present study is [...] Read more.
Background: Frailty is highly common in older patients (pts) undergoing transcatheter aortic valve replacement (TAVR), and it is associated with poor outcomes. The selection of patients who can benefit from this procedure is necessary and challenging. The aim of the present study is to evaluate outcomes in older severe aortic valve stenosis (AS) pts, selected by a multidisciplinary approach for surgical, clinical, and geriatric risk and referred to treatment, according to frailty levels. Methods: A total of 109 pts (83 ± 5 years; females, 68%) with AS were classified by Fried’s score in pre-frail, early frail, and frail and underwent surgical aortic valve replacement SAVR/TAVR, balloon aortic valvuloplasty, or medical therapy. We evaluated geriatric, clinical, and surgical features and detected periprocedural complications. The outcome was all-cause mortality. Results: Increasing frailty was associated with the worst clinical, surgical, geriatric conditions. By using Kaplan–Meier analysis, the survival rate was higher in pre-frail and TAVR groups (p < 0.001) (median follow-up = 20 months). By using the Cox regression model, frailty (p = 0.004), heart failure (p = 0.007), EF% (p = 0.043), albumin (p = 0.018) were associated with all-cause mortality. Conclusions: According to tailored frailty management, elderly AS pts with early frailty levels seem to be the most suitable candidates for TAVR/SAVR for positive outcomes because advanced frailty would make each treatment futile or palliative. Full article
(This article belongs to the Special Issue Transcatheter Aortic Valve Implantation (TAVI) II)
Show Figures

Figure 1

10 pages, 394 KiB  
Article
Long-Term Results of Serial Exercise Testing and Echocardiography Examinations in Patients with Pulmonary Stenosis
by Chia-Hsin Yang, Li-Yun Teng, Ming-Wei Lai, Ken-Pen Weng, Sen-Wei Tsai and Ko-Long Lin
J. Cardiovasc. Dev. Dis. 2023, 10(1), 31; https://doi.org/10.3390/jcdd10010031 - 16 Jan 2023
Viewed by 2723
Abstract
Pulmonary stenosis (PS) affects cardiopulmonary function and exercise performance. Cardiopulmonary exercise testing (CPET) together with transthoracic echocardiography (TTE) can measure exercise performance, PS progression, and treatment effects. We assessed exercise capacity in PS patients using these methods. We enrolled 28 PS patients aged [...] Read more.
Pulmonary stenosis (PS) affects cardiopulmonary function and exercise performance. Cardiopulmonary exercise testing (CPET) together with transthoracic echocardiography (TTE) can measure exercise performance, PS progression, and treatment effects. We assessed exercise capacity in PS patients using these methods. We enrolled 28 PS patients aged 6–35 years who received surgery, balloon pulmonary valvuloplasty, and follow-up care. The control population was selected by a 1:1 matching on age, sex, and body mass index. Baseline and follow-up peak pulmonary artery pulse wave velocity (PAV) were compared using TTE. Initial CPET revealed no significant differences in anaerobic metabolic equivalent (MET), peak oxygen consumption (VO2), and heart rate recovery between the two groups, nor were significant differences in pulmonary function identified. Within the PS group, there were no significant differences in MET, peak VO2, and heart rate recovery between the baseline and final CPET. Similarly, no significant differences were observed between the baseline and final PAV. The exercise capacity of patients with properly managed PS was comparable to that of healthy individuals. However, during the follow-up, declining trends in pulmonary function, aerobic metabolism, and peak exercise load capacity were observed among adolescents with PS. This study provides long-term data suggesting that PS patients should be encouraged to perform physical activity. Regular reevaluation should also be encouraged to limit performance deterioration. Full article
(This article belongs to the Special Issue Sports Cardiology: From Diagnosis to Clinical Management)
Show Figures

Figure 1

7 pages, 3103 KiB  
Case Report
Abnormalities of External Jugular Veins in Bulldogs with Pulmonary Valve Stenosis
by Marta Croce, Tommaso Vezzosi, Federica Marchesotti, Valentina Patata, Martina Bini, Giuseppe Lacava, Luigi Venco and Oriol Domenech
Vet. Sci. 2022, 9(7), 359; https://doi.org/10.3390/vetsci9070359 - 15 Jul 2022
Cited by 2 | Viewed by 2820
Abstract
Two French bulldogs and one English bulldog affected by pulmonary valve stenosis and referred for pulmonary balloon valvuloplasty were diagnosed with different abnormalities of the external jugular veins. The diagnosis included unilateral absence of the right external jugular vein and bilateral hypoplasia of [...] Read more.
Two French bulldogs and one English bulldog affected by pulmonary valve stenosis and referred for pulmonary balloon valvuloplasty were diagnosed with different abnormalities of the external jugular veins. The diagnosis included unilateral absence of the right external jugular vein and bilateral hypoplasia of the external jugular veins, associated with persistent left cranial vena cava. Vascular ultrasound and computed tomography were used for the diagnosis. Jugular vein anomalies can affect decision-making regarding the central venous catheterization needed to perform procedures such as pulmonary balloon valvuloplasty or central catheter placement. Based on the results of the present case series, anomalies of external jugular veins should be considered in French and English bulldogs when the external jugular veins cannot be palpated or when echocardiography shows coronary sinus dilation. Vascular ultrasound or computed tomography may help identify jugular venous anomalies and should be considered in the preoperative evaluation of bulldogs that need to undergo interventional procedures requiring transjugular catheterization. Full article
(This article belongs to the Special Issue Advances in Right Heart Diseases in Veterinary Science)
Show Figures

Figure 1

Back to TopTop