Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (16)

Search Parameters:
Keywords = Pontiac fever

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
14 pages, 1134 KiB  
Article
Development of Polymerase Chain Reaction–High-Resolution Melt Assay for Waterborne Pathogens Legionella pneumophila, Vibrio parahaemolyticus, and Camplobacter jejuni
by Shannon M. Carr and Kelly M. Elkins
Microorganisms 2024, 12(7), 1366; https://doi.org/10.3390/microorganisms12071366 - 3 Jul 2024
Viewed by 1437
Abstract
Legionella pneumophila is the waterborne pathogen primarily responsible for causing both Pontiac Fever and Legionnaire’s Disease in humans. L. pneumophila is transmitted via aerosolized water droplets. The purpose of this study was to design and test primers to allow for rapid polymerase chain [...] Read more.
Legionella pneumophila is the waterborne pathogen primarily responsible for causing both Pontiac Fever and Legionnaire’s Disease in humans. L. pneumophila is transmitted via aerosolized water droplets. The purpose of this study was to design and test primers to allow for rapid polymerase chain reaction (PCR) melt detection and identification of this infectious agent in cases of clinical or emergency response detection. New PCR primers were designed for this species of bacteria; the primer set was purchased from IDT and the target bacterial DNA was purchased from ATCC. The L. pneumophila primers targeted the macrophage infectivity potentiator gene (mip), which inhibits macrophage phagocytosis. The primers were tested for specificity, repeatability, and sensitivity using PCR–high-resolution melt (HRM) assays. The primer set was found to be specific to the designated bacteria and did not amplify the other twenty-one species from the panel. The L. pneumophila assay was able to be multiplexed. The duplex assay consists of primers for L. pneumophila and Vibrio parahaemolyticus, which are both waterborne pathogens. The triplex assay consists of primers for L. pneumophila, V. parahaemolyticus, and Campylobacter jejuni. The unique melting temperature for the L. pneumophila primer assay is 82.84 ± 0.19 °C, the C. jejuni assay is 78.10 ± 0.58 °C, and the V. parahaemolyticus assay is 86.74 ± 0.65 °C. Full article
(This article belongs to the Special Issue Advances in Research on Waterborne Pathogens)
Show Figures

Figure 1

15 pages, 802 KiB  
Article
Legionella pneumophila Presence in Dental Unit Waterlines: A Cultural and Molecular Investigation in the West Bank, Palestine
by Ashraf R. Zayed, Mutasem Burghal, Suha Butmeh, Ascel Samba-Louaka, Michael Steinert and Dina M. Bitar
Trop. Med. Infect. Dis. 2023, 8(11), 490; https://doi.org/10.3390/tropicalmed8110490 - 30 Oct 2023
Cited by 1 | Viewed by 3100
Abstract
A Legionella pneumophila bacterium is ubiquitous in water distribution systems, including dental unit waterlines (DUWLs). Legionellosis is atypical pneumonia, including Legionnaires’ disease (LD) and the less acute form of Pontiac fever. Legionellosis occurs as a result of inhalation/aspiration of aerosolized Legionella-contaminated water [...] Read more.
A Legionella pneumophila bacterium is ubiquitous in water distribution systems, including dental unit waterlines (DUWLs). Legionellosis is atypical pneumonia, including Legionnaires’ disease (LD) and the less acute form of Pontiac fever. Legionellosis occurs as a result of inhalation/aspiration of aerosolized Legionella-contaminated water by susceptible patients, health workers, and dentists. In this study, we undertook to determine the prevalence of Legionella in water and biofilm samples from Tap and DUWLs collected from five sites of dental clinics and faculties across the West Bank. Water samples were tested for physical and chemical parameters. The study samples included 185 samples, 89 (48%) water samples, and 96 (52%) biofilm swabs, which were analyzed by cultivation-dependent analysis (CDA) and by the cultivation-independent technique (CIA). Also, partial sequencing of the 16S rRNA gene for fifteen L. pneumophila isolates was performed for quality assurance and identification. L. pneumophila was isolated from 28 (15%) of 185 samples using CDA and was detected in 142 (77%) of 185 samples using CIA. The abundance of culturable L. pneumophila was low in DUWL of the sampling sites (range: 27–115 CFU/Liter). PCR was 5× more sensitive than the culture technique. L. pneumophila Sg 1 was detected in (75%) of the isolates, while (25%) isolates were L. pneumophila Sg 2–14. All fifteen sequenced Legionella isolates were identified as L. pneumophila ≥ 94.5%. The analysis of phylogenetic tree showed that L. pneumophila branch clearly identified and distinguished from other branches. These results show that DUWLs of the examined dental clinics and faculties are contaminated with L. pneumophila. This finding reveals a serious potential health risk for infection of immunocompromised patients and dentists’ post-exposure. Full article
(This article belongs to the Special Issue Clinically Relevant Bacterial Infections)
Show Figures

Figure 1

16 pages, 2546 KiB  
Article
Legionellosis-Associated Hospitalization in Spain from 2002 to 2021
by Enrique Gea-Izquierdo, Ruth Gil-Prieto, Valentín Hernández-Barrera, Gil Rodríguez-Caravaca and Ángel Gil-de-Miguel
Microorganisms 2023, 11(7), 1693; https://doi.org/10.3390/microorganisms11071693 - 29 Jun 2023
Cited by 5 | Viewed by 2246
Abstract
Legionellosis is a respiratory disease of bacterial and environmental origin that usually presents two distinct clinical entities, “Legionnaires’ disease” (LD) and “Pontiac fever”. LD is an important cause of hospital-acquired pneumonia (HAP). The objective of this study is to describe the epidemiology of [...] Read more.
Legionellosis is a respiratory disease of bacterial and environmental origin that usually presents two distinct clinical entities, “Legionnaires’ disease” (LD) and “Pontiac fever”. LD is an important cause of hospital-acquired pneumonia (HAP). The objective of this study is to describe the epidemiology of legionellosis-associated hospitalization (L-AH) in Spain from 2002 to 2021 and the burden of hospitalization due to legionellosis. Discharge reports from the Minimum Basic Data Set (MBDS) were used to retrospectively analyze hospital discharge data with a diagnosis of legionellosis, based on the ICD-9-CM and ICD-10-CM diagnosis codes, from 2002 to 2021. 21,300 L-AH occurred throughout the year during 2002–2021. The incidence of hospitalization associated per 100,000 inhabitants by month showed a similar trend for the 2002–2011, 2012–2021, and 2002–2021 periods. In Spain, during 2002–2021, the hospitalization rate (HR) in the autonomous communities ranged from 4.57 (2002–2011) to 0.24 (2012–2021) cases per 100,000 inhabitants. The HR of legionellosis in Spain has substantially increased across the 2002–2021 period, and the estimate is consistent with available European data. It is considered that in-depth epidemiological surveillance studies of legionellosis and improvements in the prevention and control of the disease are required in Spain. Full article
Show Figures

Figure 1

14 pages, 9877 KiB  
Article
A Pilot Study for Legionella pneumophila Volatilome Characterization Using a Gas Sensor Array and GC/MS Techniques
by Rosamaria Capuano, Antonella Mansi, Emilia Paba, Anna Maria Marcelloni, Alessandra Chiominto, Anna Rita Proietto, Andrea Gordiani, Alexandro Catini, Roberto Paolesse, Giovanna Tranfo and Corrado Di Natale
Sensors 2023, 23(3), 1401; https://doi.org/10.3390/s23031401 - 26 Jan 2023
Cited by 7 | Viewed by 2826
Abstract
Legionellosis is a generic term describing the pneumonic (Legionnaires’ disease, LD) and non-pneumonic (Pontiac fever, PF) forms of infection with bacteria belonging to the genus Legionella. Currently, the techniques used to detect Legionella spp. in water samples have certain limitations and drawbacks, [...] Read more.
Legionellosis is a generic term describing the pneumonic (Legionnaires’ disease, LD) and non-pneumonic (Pontiac fever, PF) forms of infection with bacteria belonging to the genus Legionella. Currently, the techniques used to detect Legionella spp. in water samples have certain limitations and drawbacks, and thus, there is a need to identify new tools to carry out low-cost and rapid analysis. In this regard, several studies demonstrated that a volatolomics approach rapidly detects and discriminates different species of microorganisms via their volatile signature. In this paper, the volatile organic compounds (VOCs) pattern emitted in vitro by Legionella pneumophila cultures is characterized and compared to those produced by other Legionella species and by Pseudomonas aeruginosa, using a gas sensor array and gas chromatograph mass spectrometer (GC-MS). Bacterial cultures were measured at the 3rd and 7th day after the incubation. Sensor array data analyzed via the K-nearest neighbours (k-NN) algorithm showed a sensitivity to Legionella pneumophila identification at around 89%. On the other hand, GC-MS identified a bouquet of VOCs, mainly alcohols and ketones, that enable the differentiation of Legionella pneumophila in respect to other waterborne microorganisms. Full article
Show Figures

Figure 1

32 pages, 865 KiB  
Review
Concept about the Virulence Factor of Legionella
by Jin-Lei Yang, Danyang Li and Xiao-Yong Zhan
Microorganisms 2023, 11(1), 74; https://doi.org/10.3390/microorganisms11010074 - 27 Dec 2022
Cited by 14 | Viewed by 8885
Abstract
Pathogenic species of Legionella can infect human alveolar macrophages through Legionella-containing aerosols to cause a disease called Legionellosis, which has two forms: a flu-like Pontiac fever and severe pneumonia named Legionnaires’ disease (LD). Legionella is an opportunistic pathogen that frequently presents in [...] Read more.
Pathogenic species of Legionella can infect human alveolar macrophages through Legionella-containing aerosols to cause a disease called Legionellosis, which has two forms: a flu-like Pontiac fever and severe pneumonia named Legionnaires’ disease (LD). Legionella is an opportunistic pathogen that frequently presents in aquatic environments as a biofilm or protozoa parasite. Long-term interaction and extensive co-evolution with various genera of amoebae render Legionellae pathogenic to infect humans and also generate virulence differentiation and heterogeneity. Conventionally, the proteins involved in initiating replication processes and human macrophage infections have been regarded as virulence factors and linked to pathogenicity. However, because some of the virulence factors are associated with the infection of protozoa and macrophages, it would be more accurate to classify them as survival factors rather than virulence factors. Given that the molecular basis of virulence variations among non-pathogenic, pathogenic, and highly pathogenic Legionella has not yet been elaborated from the perspective of virulence factors, a comprehensive explanation of how Legionella infects its natural hosts, protozoans, and accidental hosts, humans is essential to show a novel concept regarding the virulence factor of Legionella. In this review, we overviewed the pathogenic development of Legionella from protozoa, the function of conventional virulence factors in the infections of protozoa and macrophages, the host’s innate immune system, and factors involved in regulating the host immune response, before discussing a probably new definition for the virulence factors of Legionella. Full article
(This article belongs to the Special Issue Intracellular Bacteria: From Basic Research to Clinics 2.0)
Show Figures

Figure 1

12 pages, 2082 KiB  
Article
The Effect Citrox BCL on Legionella pneumophila Mechanisms of Biofilm Formation, Oxidative Stress and Virulence
by Eugenia Butucel, Igori Balta, David McCleery, Cosmin Alin Popescu, Tiberiu Iancu, Ioan Pet, Adela Marcu, Nicolae-Marinel Horablaga, Lavinia Stef and Nicolae Corcionivoschi
Antioxidants 2022, 11(11), 2186; https://doi.org/10.3390/antiox11112186 - 4 Nov 2022
Cited by 5 | Viewed by 2529
Abstract
Legionella pneumophila is responsible for causing Legionnaires’ disease and Pontiac fever, also known as legionellosis. The aim of this study was to investigate the mechanistic effect of a mixture of natural antimicrobials (Citrox BCL) in preventing L. pneumophila biofilm formation and reducing its [...] Read more.
Legionella pneumophila is responsible for causing Legionnaires’ disease and Pontiac fever, also known as legionellosis. The aim of this study was to investigate the mechanistic effect of a mixture of natural antimicrobials (Citrox BCL) in preventing L. pneumophila biofilm formation and reducing its in vitro virulence. The minimum inhibitory concentrations were detected at 0.06%, and the MBC was established at 0.125%. Based on the growth curve profile, the sub-inhibitory concentration of 0.02% was further used to study the mechanistic implications in the absence of a cytotoxic effect on A549 cells. At 24 h post-infection, Citrox BCL reduced (p = 0.005) the intracellular growth of L. pneumophila when the A549 cells or the bacteria were pre-treated with 0.02% Citrox BCL. This result was replicated when Citrox BCL was added during the 24 h infection assay leading to a reduction in intracellular growth (p = 0.003). Herein we show that at the sub-inhibitory concentration of 0.02%, Citrox CBL lowers the ROS levels in infected A549 cells and causes a 45% reduction in L. pneumophila EPS production, a reduction associated with the decline in biofilm formation. Overall, our results corroborate the low c-di-GMP production with the decrease in biofilm formation and low EPS levels. The low EPS levels seemed to be caused by the downregulation of the tatB and tatC gene expressions. Moreover, inhibition of pvcA and pvcB gene expressions, leading to lower siderophore levels, suggests that Citrox BCL reduces the ability of L. pneumophila to sequester iron and reduce biofilm formation through iron starvation. Full article
Show Figures

Figure 1

18 pages, 2097 KiB  
Review
Legionella pneumophila: The Journey from the Environment to the Blood
by Valeria Iliadi, Jeni Staykova, Sergios Iliadis, Ina Konstantinidou, Polina Sivykh, Gioulia Romanidou, Daniil F. Vardikov, Dimitrios Cassimos and Theocharis G. Konstantinidis
J. Clin. Med. 2022, 11(20), 6126; https://doi.org/10.3390/jcm11206126 - 18 Oct 2022
Cited by 27 | Viewed by 9013
Abstract
An outbreak of a potentially fatal form of pneumonia in 1976 and in the annual convention of the American Legion was the first time that Legionella spp. was identified. Thereafter, the term Legionnaires’ disease (LD) was established. The infection in humans is transmitted [...] Read more.
An outbreak of a potentially fatal form of pneumonia in 1976 and in the annual convention of the American Legion was the first time that Legionella spp. was identified. Thereafter, the term Legionnaires’ disease (LD) was established. The infection in humans is transmitted by the inhalation of aerosols that contain the microorganisms that belong to the Legionellaceae family and the genus Legionella. The genus Legionella contains genetically heterogeneous species and serogroups. The Legionella pneumophila serogroup 1 (Lp1) is the most often detected strain in outbreaks of LD. The pathogenesis of LD infection initiates with the attachment of the bacterial cells to the host cells, and subsequent intracellular replication. Following invasion, Legionella spp. activates its virulence mechanisms: generation of specific compartments of Legionella-containing vacuole (LCV), and expression of genes that encode a type IV secretion system (T4SS) for the translocation of proteins. The ability of L. pneumophila to transmigrate across the lung’s epithelium barrier leads to bacteremia, spread, and invasion of many organs with subsequent manifestations, complications, and septic shock. The clinical manifestations of LD depend on the bacterial load in the aerosol, the virulence factors, and the immune status of the patient. The infection has two distinct forms: the non- pneumatic form or Pontiac fever, which is a milder febrile flu-like illness, and LD, a more severe form, which includes pneumonia. In addition, the extrapulmonary involvement of LD can include heart, brain, abdomen, and joints. Full article
Show Figures

Figure 1

16 pages, 21231 KiB  
Article
Rutile-TiO2/PtO2 Glass Coatings Disinfects Aquatic Legionella pneumophila via Morphology Change and Endotoxin Degradation under LED Irradiation
by Ryosuke Matsuura, Arisa Kawamura, Yasunobu Matsumoto, Takashi Fukushima, Kazuhiro Fujimoto, Heihachiro Ochiai, Junichi Somei and Yoko Aida
Catalysts 2022, 12(8), 856; https://doi.org/10.3390/catal12080856 - 3 Aug 2022
Cited by 8 | Viewed by 3407
Abstract
Legionella pneumophila (L. pneumophila) is the causative agent of Legionnaires’ disease and Pontiac fever, collectively known as legionellosis. L. pneumophila infection occurs through inhalation of contaminated aerosols from water systems in workplaces and institutions. The development of disinfectants that can eliminate [...] Read more.
Legionella pneumophila (L. pneumophila) is the causative agent of Legionnaires’ disease and Pontiac fever, collectively known as legionellosis. L. pneumophila infection occurs through inhalation of contaminated aerosols from water systems in workplaces and institutions. The development of disinfectants that can eliminate L. pneumophila in such water systems without evacuating people is needed to prevent the spread of L. pneumophila. Photocatalysts are attractive disinfectants that do not harm human health. In particular, the TiO2 photocatalyst kills L. pneumophila under various conditions, but its mode of action is unknown. Here, we confirmed the high performance of TiO2 photocatalyst containing PtO2 via the degradation of methylene blue (half-value period: 19.2 min) and bactericidal activity against Escherichia coli (half-value period: 15.1 min) in water. Using transmission electron microscopy, we demonstrate that the disinfection of L. pneumophila (half-value period: 6.7 min) by TiO2 photocatalyst in water is accompanied by remarkable cellular membrane and internal damage to L. pneumophila. Assays with limulus amebocyte lysate and silver staining showed the release of endotoxin from L. pneumophila due to membrane damage and photocatalytic degradation of this endotoxin. This is the first study to demonstrate the disinfection mechanisms of TiO2 photocatalyst, namely, via morphological changes and membrane damage of L. pneumophila. Our results suggest that TiO2 photocatalyst might be effective in controlling the spread of L. pneumophila. Full article
(This article belongs to the Special Issue Innovative Functional Materials in Photocatalysis)
Show Figures

Figure 1

13 pages, 2175 KiB  
Article
Development of a Novel Peptide Nucleic Acid Probe for the Detection of Legionella spp. in Water Samples
by Montserrat Nácher-Vázquez, Ana Barbosa, Inês Armelim, Andreia Sofia Azevedo, Gonçalo Nieto Almeida, Cristina Pizarro, Nuno Filipe Azevedo, Carina Almeida and Laura Cerqueira
Microorganisms 2022, 10(7), 1409; https://doi.org/10.3390/microorganisms10071409 - 13 Jul 2022
Cited by 5 | Viewed by 3133
Abstract
Legionella are opportunistic intracellular pathogens that are found throughout the environment. The Legionella contamination of water systems represents a serious social problem that can lead to severe diseases, which can manifest as both Pontiac fever and Legionnaires’ disease (LD) infections. Fluorescence in situ [...] Read more.
Legionella are opportunistic intracellular pathogens that are found throughout the environment. The Legionella contamination of water systems represents a serious social problem that can lead to severe diseases, which can manifest as both Pontiac fever and Legionnaires’ disease (LD) infections. Fluorescence in situ hybridization using nucleic acid mimic probes (NAM-FISH) is a powerful and versatile technique for bacterial detection. By optimizing a peptide nucleic acid (PNA) sequence based on fluorescently selective binding to specific bacterial rRNA sequences, we established a new PNA-FISH method that has been successfully designed for the specific detection of the genus Legionella. The LEG22 PNA probe has shown great theoretical performance, presenting 99.9% specificity and 96.9% sensitivity. We also demonstrated that the PNA-FISH approach presents a good signal-to-noise ratio when applied in artificially contaminated water samples directly on filtration membranes or after cells elution. For water samples with higher turbidity (from cooling tower water systems), there is still the need for further method optimization in order to detect cellular contents and to overcome interferents’ autofluorescence, which hinders probe signal visualization. Nevertheless, this work shows that the PNA-FISH approach could be a promising alternative for the rapid (3–4 h) and accurate detection of Legionella. Full article
Show Figures

Figure 1

19 pages, 3260 KiB  
Article
Decreasing Pasteurization Treatment Efficiency against Amoeba-Grown Legionella pneumophila—Recognized Public Health Risk Factor
by Maša Knežević, Dobrica Rončević, Darija Vukić Lušić, Mirna Mihelčić, Rok Kogoj, Darja Keše, Marin Glad, Arijana Cenov, Mateja Ožanič, Daniela Glažar Ivče and Marina Šantić
Int. J. Environ. Res. Public Health 2022, 19(3), 1099; https://doi.org/10.3390/ijerph19031099 - 19 Jan 2022
Cited by 3 | Viewed by 2908
Abstract
Legionellae are gram-negative bacteria most commonly found in freshwater ecosystems and purpose-built water systems. In humans, the bacterium causes Legionnaires’ disease (LD) or a Pontiac fever. In this study, the different waters (drinking water, pool water, cooling towers) in which Legionella pneumophila has [...] Read more.
Legionellae are gram-negative bacteria most commonly found in freshwater ecosystems and purpose-built water systems. In humans, the bacterium causes Legionnaires’ disease (LD) or a Pontiac fever. In this study, the different waters (drinking water, pool water, cooling towers) in which Legionella pneumophila has been isolated were studied to assess the possible risk of bacterial spreading in the population. The influence of physical and chemical parameters, and interactions with Acanthamoeba castellanii on L. pneumophila, were analyzed by Heterotrophic Plate Count, the Colony-forming units (CFU) methods, transmission electron microscopy (TEM), and Sequence-Based Typing (SBT) analysis. During the study period (2013–2019), a total of 1932 water samples were analyzed, with the average annual rate of Legionella-positive water samples of 8.9%, showing an increasing trend. The largest proportion of Legionella-positive samples was found in cooling towers and rehabilitation centers (33.9% and 33.3%, respectively). Among the isolates, L. pneumophila SGs 2–14 was the most commonly identified strain (76%). The survival of Legionella was enhanced in the samples with higher pH values, while higher electrical conductivity, nitrate, and free residual chlorine concentration significantly reduced the survival of Legionella. Our results show that growth in amoeba does not affect the allelic profile, phenotype, and morphology of the bacterium but environmental L. pneumophila becomes more resistant to pasteurization treatment. Full article
Show Figures

Figure 1

11 pages, 883 KiB  
Systematic Review
Severe Pneumonia in Neonates Associated with Legionella pneumophila: Case Report and Review of the Literature
by Alba Perez Ortiz, Camilla Hahn, Thomas Schaible, Neysan Rafat and Bettina Lange
Pathogens 2021, 10(8), 1031; https://doi.org/10.3390/pathogens10081031 - 15 Aug 2021
Cited by 16 | Viewed by 4538
Abstract
The causative agent of legionellosis is the Gram-negative intracellular bacteria Legionella spp. Its clinical presentation varies from a mild febrile illness called Pontiac fever to the severe and possible fatal pneumonia, Legionnaires’ disease. Immunocompromised patients, in particular, are affected. Only a small number [...] Read more.
The causative agent of legionellosis is the Gram-negative intracellular bacteria Legionella spp. Its clinical presentation varies from a mild febrile illness called Pontiac fever to the severe and possible fatal pneumonia, Legionnaires’ disease. Immunocompromised patients, in particular, are affected. Only a small number of infected neonates are described in the literature. Most of them have been associated with water birth or the use of air humidifiers. In the last five years, a growing number of cases have been reported in Germany by the national institute of disease surveillance and prevention (Robert-Koch Institute). Here, we describe a fatal case report of pulmonary legionellosis with acute respiratory distress syndrome (ARDS), sepsis, associated cutaneous manifestation, and extracorporeal membrane oxygenation in a full-term neonate. Moreover, we present a review of the literature discussing the epidemiology, risk factors, clinical features, diagnostics, treatment options, and prevention for this rare condition in neonates. Full article
(This article belongs to the Special Issue Respiratory Tract Infections in Children)
Show Figures

Figure 1

17 pages, 555 KiB  
Review
Legionellosis Caused by Non-Legionella pneumophila Species, with a Focus on Legionella longbeachae
by Stephen T. Chambers, Sandy Slow, Amy Scott-Thomas and David R. Murdoch
Microorganisms 2021, 9(2), 291; https://doi.org/10.3390/microorganisms9020291 - 31 Jan 2021
Cited by 51 | Viewed by 7828
Abstract
Although known as causes of community-acquired pneumonia and Pontiac fever, the global burden of infection caused by Legionella species other than Legionella pneumophila is under-recognised. Non-L. pneumophila legionellae have a worldwide distribution, although common testing strategies for legionellosis favour detection of L. [...] Read more.
Although known as causes of community-acquired pneumonia and Pontiac fever, the global burden of infection caused by Legionella species other than Legionella pneumophila is under-recognised. Non-L. pneumophila legionellae have a worldwide distribution, although common testing strategies for legionellosis favour detection of L. pneumophila over other Legionella species, leading to an inherent diagnostic bias and under-detection of cases. When systematically tested for in Australia and New Zealand, L. longbeachae was shown to be a leading cause of community-acquired pneumonia. Exposure to potting soils and compost is a particular risk for infection from L. longbeachae, and L. longbeachae may be better adapted to soil and composting plant material than other Legionella species. It is possible that the high rate of L. longbeachae reported in Australia and New Zealand is related to the composition of commercial potting soils which, unlike European products, contain pine bark and sawdust. Genetic studies have demonstrated that the Legionella genomes are highly plastic, with areas of the chromosome showing high levels of recombination as well as horizontal gene transfer both within and between species via plasmids. This, combined with various secretion systems and extensive effector repertoires that enable the bacterium to hijack host cell functions and resources, is instrumental in shaping its pathogenesis, survival and growth. Prevention of legionellosis is hampered by surveillance systems that are compromised by ascertainment bias, which limits commitment to an effective public health response. Current prevention strategies in Australia and New Zealand are directed at individual gardeners who use potting soils and compost. This consists of advice to avoid aerosols generated by the use of potting soils and use masks and gloves, but there is little evidence that this is effective. There is a need to better understand the epidemiology of L. longbeachae and other Legionella species in order to develop effective treatment and preventative strategies globally. Full article
Show Figures

Figure 1

16 pages, 817 KiB  
Review
European Surveillance of Legionnaires' Disease
by Birgitta de Jong and Lara Payne Hallström
Curr. Issues Mol. Biol. 2021, 42(1), 81-96; https://doi.org/10.21775/cimb.042.081 - 7 Dec 2020
Cited by 14 | Viewed by 1452
Abstract
Legionnaires' disease and Pontiac fever are both diseases with important public health implications and require prompt and thorough responses to outbreaks for future prevention. Effective methods for defining, diagnosing, reporting and responding to legionellosis outbreaks ideally should be standardized across countries. Therefore, the [...] Read more.
Legionnaires' disease and Pontiac fever are both diseases with important public health implications and require prompt and thorough responses to outbreaks for future prevention. Effective methods for defining, diagnosing, reporting and responding to legionellosis outbreaks ideally should be standardized across countries. Therefore, the European Union surveillance methods for countering Legionnaires' disease is a useful model especially for travel-associated Legionnaires' disease (TALD) cases which are on the rise. Multi-country surveillance in the EU and European Economic Area (EEA) has evolved since the first organizational efforts in the 1980's to the currently responsible, European Legionnaires' Disease Surveillance Network (ELDSNet). This chapter outlines the practices of the EU surveillance of Legionnaires' disease including their schemata, definitions, responsibilities of participating members, methods and the results of the data collected since the program's inception. Lastly, improvements must still be made as the incidence of Legionnaires' disease in the EU is likely underestimated due to underreporting and/or underdiagnosis. Nearly 70% of cases are reported from only four countries, France, Germany, Italy and Spain, which represent 50% of the EU population. Full article
23 pages, 487 KiB  
Review
Legionella pneumophila and Protozoan Hosts: Implications for the Control of Hospital and Potable Water Systems
by Muhammad Atif Nisar, Kirstin E. Ross, Melissa H. Brown, Richard Bentham and Harriet Whiley
Pathogens 2020, 9(4), 286; https://doi.org/10.3390/pathogens9040286 - 15 Apr 2020
Cited by 40 | Viewed by 5888
Abstract
Legionella pneumophila is an opportunistic waterborne pathogen of public health concern. It is the causative agent of Legionnaires’ disease (LD) and Pontiac fever and is ubiquitous in manufactured water systems, where protozoan hosts and complex microbial communities provide protection from disinfection procedures. This [...] Read more.
Legionella pneumophila is an opportunistic waterborne pathogen of public health concern. It is the causative agent of Legionnaires’ disease (LD) and Pontiac fever and is ubiquitous in manufactured water systems, where protozoan hosts and complex microbial communities provide protection from disinfection procedures. This review collates the literature describing interactions between L. pneumophila and protozoan hosts in hospital and municipal potable water distribution systems. The effectiveness of currently available water disinfection protocols to control L. pneumophila and its protozoan hosts is explored. The studies identified in this systematic literature review demonstrated the failure of common disinfection procedures to achieve long term elimination of L. pneumophila and protozoan hosts from potable water. It has been demonstrated that protozoan hosts facilitate the intracellular replication and packaging of viable L. pneumophila in infectious vesicles; whereas, cyst-forming protozoans provide protection from prolonged environmental stress. Disinfection procedures and protozoan hosts also facilitate biogenesis of viable but non-culturable (VBNC) L. pneumophila which have been shown to be highly resistant to many water disinfection protocols. In conclusion, a better understanding of L. pneumophila-protozoan interactions and the structure of complex microbial biofilms is required for the improved management of L. pneumophila and the prevention of LD. Full article
(This article belongs to the Special Issue Legionella Contamination in Water Environment)
Show Figures

Figure 1

18 pages, 2832 KiB  
Article
An Advanced Risk Modeling Method to Estimate Legionellosis Risks Within a Diverse Population
by Mark H. Weir, Alexis L. Mraz and Jade Mitchell
Water 2020, 12(1), 43; https://doi.org/10.3390/w12010043 - 20 Dec 2019
Cited by 11 | Viewed by 4761
Abstract
Quantitative microbial risk assessment (QMRA) is a computational science leveraged to optimize infectious disease controls at both population and individual levels. Often, diverse populations will have different health risks based on a population’s susceptibility or outcome severity due to heterogeneity within the host. [...] Read more.
Quantitative microbial risk assessment (QMRA) is a computational science leveraged to optimize infectious disease controls at both population and individual levels. Often, diverse populations will have different health risks based on a population’s susceptibility or outcome severity due to heterogeneity within the host. Unfortunately, due to a host homogeneity assumption in the microbial dose-response models’ derivation, the current QMRA method of modeling exposure volume heterogeneity is not an accurate method for pathogens such as Legionella pneumophila. Therefore, a new method to model within-group heterogeneity is needed. The method developed in this research uses USA national incidence rates from the Centers for Disease Control and Prevention (CDC) to calculate proxies for the morbidity ratio that are descriptive of the within-group variability. From these proxies, an example QMRA model is developed to demonstrate their use. This method makes the QMRA results more representative of clinical outcomes and increases population-specific precision. Further, the risks estimated demonstrate a significant difference between demographic groups known to have heterogeneous health outcomes after infection. The method both improves fidelity to the real health impacts resulting from L. pneumophila infection and allows for the estimation of severe disability-adjusted life years (DALYs) for Legionnaires’ disease, moderate DALYs for Pontiac fever, and post-acute DALYs for sequela after recovering from Legionnaires’ disease. Full article
(This article belongs to the Section Water Quality and Contamination)
Show Figures

Figure 1

Back to TopTop