Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (43)

Search Parameters:
Keywords = ICNIRP limits

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
32 pages, 2477 KB  
Review
Research Progress on High-Frequency Electromagnetic Environments in the Internet of Vehicles
by Jiakun Li, Mai Lu and Shirun Wang
Electronics 2026, 15(15), 3418; https://doi.org/10.3390/electronics15153418 - 2 Aug 2026
Viewed by 135
Abstract
With the increasing demand for clean energy and low-carbon transportation, next-generation vehicles integrating high-frequency electronic systems have become more complex, raising concerns about in-vehicle electromagnetic exposure. This paper reviews high-frequency devices operating in the 30 kHz–300 GHz range and systematically analyzes the spatial [...] Read more.
With the increasing demand for clean energy and low-carbon transportation, next-generation vehicles integrating high-frequency electronic systems have become more complex, raising concerns about in-vehicle electromagnetic exposure. This paper reviews high-frequency devices operating in the 30 kHz–300 GHz range and systematically analyzes the spatial distribution and key frequency characteristics of electromagnetic sources in vehicles. The results show that, even under worst-case conditions, electromagnetic exposure levels for occupants remain well below the safety limits defined by ICNIRP. For example, in a worst-case 5.9 GHz V2V communication scenario, the driver’s head SAR10g reaches 0.981 W/kg (9.81% of the ICNIRP occupational limit), while the whole-body SAR is only 0.008728 W/kg with negligible temperature rise. Other systems, including 5G-V2X, automotive radar, and mobile phones, also produce exposure levels far below safety thresholds. These findings suggest that RF exposure levels for vehicle occupants remain low relative to current guideline limits under the assessed scenarios. However, key challenges remain, including limited studies on multi-source exposure, insufficient data on vulnerable populations, simplified simulation conditions, lack of standardized validation methods, and inadequate assessment of emerging technologies. This work provides a quantitative basis for future safety standards and highlights critical research directions. Full article
Show Figures

Figure 1

13 pages, 1275 KB  
Article
Continuous Monitoring of Magnetic Fields in AC/DC Electric Rail Systems: A Comparative Analysis of Light and Heavy Rail Passenger Exposure
by Liran Shmuel Raz-Steinkrycer, Stelian Gelberg, Ehud Neeman and Boris A. Portnov
Sustainability 2026, 18(12), 6227; https://doi.org/10.3390/su18126227 - 17 Jun 2026
Cited by 1 | Viewed by 271
Abstract
Electrification of public transit is central to sustainable urban development, yet it introduces passenger exposure to extremely low-frequency magnetic fields (ELF-MFs), which the International Agency for Research on Cancer (IARC) classifies as possibly carcinogenic to humans (Group 2B). This study presents a systematic [...] Read more.
Electrification of public transit is central to sustainable urban development, yet it introduces passenger exposure to extremely low-frequency magnetic fields (ELF-MFs), which the International Agency for Research on Cancer (IARC) classifies as possibly carcinogenic to humans (Group 2B). This study presents a systematic cross-platform comparison of ELF-MF exposure in direct current (DC) light rail and alternating current (AC) heavy rail systems operating under a single national regulatory framework. A total of 9100 continuous measurements were collected across 28 trips on the Tel Aviv Red Line light rail transit (1500 V DC) and the Israel Railways Tel Aviv–Binyamina corridor (25 kV, 50 Hz AC) during 23–26 November 2025, using calibrated Tenmars TM-192D gaussmeters. Mean passenger seat magnetic flux density was 0.226 ± 0.147 µT (2.26 ± 1.47 mG) for the DC system and 0.900 ± 0.606 µT (9.00 ± 6.06 mG) for the AC system. The difference was highly significant (Welch’s t = −73.06, p < 0.001). DC light rail exposure remained consistently below Israel’s precautionary 0.4 µT (4 mG) threshold for continuous public exposure, whereas AC heavy rail mean levels exceeded this threshold in every monitored trip while remaining far below ICNIRP general public reference levels. These findings highlight a “Green Dilemma” in sustainable transport policy: the environmental benefits of rail electrification must be balanced with prudent electromagnetic exposure management in jurisdictions applying strict precautionary limits. Full article
(This article belongs to the Section Sustainable Transportation)
Show Figures

Figure 1

21 pages, 3403 KB  
Article
Workers’ Exposure Due to Private 5G Networks
by Blaž Valič, David Plets, Gunter Vermeeren, Christos Apostolidis and Peter Gajšek
Telecom 2026, 7(3), 63; https://doi.org/10.3390/telecom7030063 - 1 Jun 2026
Viewed by 703
Abstract
Private 5G mobile networks are emerging as a platform for wireless connectivity in professional applications across smart industrial sectors such as automated warehousing, logistics, autonomous vehicle deployments in campus environments, mining, and material processing, among others. It is expected that most Machine-to-Machine (M2M) [...] Read more.
Private 5G mobile networks are emerging as a platform for wireless connectivity in professional applications across smart industrial sectors such as automated warehousing, logistics, autonomous vehicle deployments in campus environments, mining, and material processing, among others. It is expected that most Machine-to-Machine (M2M) and Industrial Internet of Things (IIoT) communication links will increasingly rely on wireless solutions, as the flexibility they offer provides clear advantages over hard-wired network installations. To gain insight into workers’ exposure to radiofrequency electromagnetic fields (RF EMF) emitted by 5G private mobile networks, an analysis was conducted based on measured and calculated RF EMF levels from various 5G private networks in real-world scenarios across different smart industrial sectors and R&D platforms in three countries. Several exposure scenarios were evaluated, including production facilities, logistics operations, office environments, and research sites. The installations included different configurations: private standalone and non-standalone 5G networks operating at 3.5 GHz and 26 GHz, as well as public networks with private slicing. The results clearly demonstrated that exposure levels in all investigated scenarios were well below existing exposure limits. In a typical indoor industrial environment where pico 5G base stations are deployed, the measured exposure was found to be no greater than 0.006% of the Directive 2013/35/EU action value and 0.03% of the ICNIRP guideline limits for the general public. Full article
Show Figures

Figure 1

18 pages, 8189 KB  
Article
Electromagnetic Exposure Assessment of 5G Mobile Phones: SAR and Thermal Distribution in a Multi-Layer Human Head Model
by Dengpeng Chen and Bingtao Zhang
Sensors 2026, 26(5), 1468; https://doi.org/10.3390/s26051468 - 26 Feb 2026
Cited by 1 | Viewed by 1015
Abstract
The rapid deployment of 5G technology has raised public concern regarding the potential health effects of electromagnetic radiation from mobile devices. This study systematically evaluates the specific absorption rate (SAR) and temperature distribution in a multi-layer spherical head model exposed to near-field radiation [...] Read more.
The rapid deployment of 5G technology has raised public concern regarding the potential health effects of electromagnetic radiation from mobile devices. This study systematically evaluates the specific absorption rate (SAR) and temperature distribution in a multi-layer spherical head model exposed to near-field radiation from a 5G mobile phone antenna. A planar inverted-F antenna (PIFA) covering the 3.5 GHz band was integrated into a smartphone model, and simulations were performed in COMSOL Multiphysics 6.3 under input powers of 21 dBm and 24 dBm at varying antenna–head distances. The results show that the peak SAR in the brain layer remained at 0.034 W/kg and 0.065 W/kg for the two power levels, both well below the International Commission on Non-Ionizing Radiation Protection (ICNIRP) safety limit of 2 W/kg. The highest SAR occurred in the scalp layer, decreasing gradually through the skull and brain tissues. After 30 min of exposure, the maximum brain temperature reached only 37.223 °C, far lower than the thermal damage threshold. Increasing the antenna–head distance from 5 mm to 30 mm reduced SAR by up to 50.2%, while temperature variations remained negligible (≤0.18%). These findings demonstrate that under typical usage conditions, 5G mobile phone radiation complies with international safety standards and poses no significant thermal risk, thereby contributing to a deeper understanding of bio-electromagnetic interactions and supporting ongoing wireless-communication safety assessments. Full article
(This article belongs to the Section Communications)
Show Figures

Figure 1

26 pages, 6104 KB  
Article
Electromagnetic Exposure from RF Antennas on Subway Station Attendant: A Thermal Analysis
by Jin Li, Qianqian Zhang and Mai Lu
Sensors 2026, 26(2), 709; https://doi.org/10.3390/s26020709 - 21 Jan 2026
Cited by 1 | Viewed by 808
Abstract
With the rapid development of wireless communication systems, the electromagnetic environment in subway stations has become increasingly complex, raising concerns about the long-term safety of station attendants who are chronically exposed to radiofrequency (RF) fields. At present, multiphysics analyses specifically addressing RF antenna [...] Read more.
With the rapid development of wireless communication systems, the electromagnetic environment in subway stations has become increasingly complex, raising concerns about the long-term safety of station attendants who are chronically exposed to radiofrequency (RF) fields. At present, multiphysics analyses specifically addressing RF antenna exposure scenarios for subway attendants remain limited. To assess occupational electromagnetic exposure risks, this paper establishes a comprehensive electromagnetic–thermal coupling simulation model incorporating RF antennas, station-platform structures, and a realistic human model with organs including the brain, heart, and liver. Using the finite-element software COMSOL Multiphysics (v.6.3), numerical simulations are performed to calculate the specific absorption rate (SAR) in the trunk and major organs of the subway station attendant at RF antennas frequencies of 900 MHz, 2600 MHz, and 3500 MHz, as well as the temperature rise distribution of the human trunk and important tissues and organs under different initial temperatures of the environment. The results show that among the three frequencies, the maximum SAR of 5.55 × 104 W/kg occurs in the trunk at 3500 MHz. Tissue temperatures reach thermal steady state after 30 min of exposure, with the maximum temperature rises occurring in the brain at an ambient temperature of 18 °C and an operating frequency of 900 MHz, reaching 0.2123 °C. Across all simulated scenarios, both SAR values and temperature rises remain significantly below the occupational exposure limits established by the International Commission on Non-Ionizing Radiation Protection (ICNIRP). These findings indicate that RF radiation generated by antennas in the subway station environment poses low health risks to female station attendants of similar physical characteristics to the Ella model. This study provides a scientific reference for the occupational RF protection of subway personnel and contributes data for the development of electromagnetic exposure standards in rail transit systems. Full article
(This article belongs to the Section Physical Sensors)
Show Figures

Figure 1

23 pages, 14833 KB  
Article
Assessment of Electromagnetic Exposure Levels for Humans from Electric Vehicle DC Charging Stations
by Shaowen Dong and Mai Lu
Sensors 2025, 25(18), 5735; https://doi.org/10.3390/s25185735 - 14 Sep 2025
Cited by 4 | Viewed by 6719
Abstract
The potential health risks of DC charging piles to human health were investigated by quantifying the internal electromagnetic exposure level. In this study, the transformer in the DC/DC circuit of a DC charging pile was selected as the radiation source, and two realistic [...] Read more.
The potential health risks of DC charging piles to human health were investigated by quantifying the internal electromagnetic exposure level. In this study, the transformer in the DC/DC circuit of a DC charging pile was selected as the radiation source, and two realistic human models (adult and child) were used as exposure subjects. A simulation model, including the vehicle body, charging pile, and transformer, was established using COMSOL(COMSOL Multiphysics 6.2) Multiphysics software to calculate the magnetic induction intensity (B-field) and electric field intensity (E-field) in various organs at distances of 0.1 m, 0.3 m, and 0.6 m from the charging pile. The results show that at 0.1 m, the peak B-field (1.91 µT) and E-field (447 mV/m) in the adult body were 1.91% and 2.07% of the ICNIRP occupational exposure limits, respectively, and 7.07% and 4.14% of the public exposure limits. For the child model, the peak electromagnetic exposure levels (2.31 µT and 259 mV/m) were only 8.56% and 2.40% of the public limits. Further evaluation of exposure levels for in-vehicle occupants during charging showed that the peak B-field and E-field for an adult driver and a child in the front passenger seat were 0.0225 × 10−2 µT, 0.0237 × 10−2 µT, 5.81 mV/m, and 5.82 mV/m, respectively, far below the ICNIRP public limits. Additionally, analyses at multiple frequency bands (85 kHz, 90 kHz, and 95 kHz) under a typical scenario (adult at 0.1 m from the charging pile) revealed that the B-field in the human body decreased with increasing frequency, while the E-field showed minimal variation due to shielding effects. All electromagnetic exposure levels were below both ICNIRP public and occupational limits, indicating the broad applicability of the results. Under normal operating conditions of DC charging piles, the electromagnetic exposure from the DC/DC transformer fully complies with safety standards and poses no threat to human health. This study provides a scientific basis for alleviating public concerns about the health risks of electromagnetic radiation from DC charging piles for electric vehicles. Full article
(This article belongs to the Section Vehicular Sensing)
Show Figures

Figure 1

19 pages, 2476 KB  
Article
Magnetic Field Analysis of Unconventional High Surge Impedance Loading (HSIL) Transmission Lines with Different Subconductor Configurations: Numerical Comparisons and Performance Evaluation
by Easir Arafat, Babak Porkar and Mona Ghassemi
Magnetism 2025, 5(3), 20; https://doi.org/10.3390/magnetism5030020 - 5 Sep 2025
Cited by 1 | Viewed by 2140
Abstract
High-voltage transmission lines are the backbone of modern power systems, facilitating the delivery of electricity from diverse generation sources, including conventional power plants and renewable energy systems, to consumers. As the electricity demand grows, the expansion of transmission infrastructure becomes essential to connecting [...] Read more.
High-voltage transmission lines are the backbone of modern power systems, facilitating the delivery of electricity from diverse generation sources, including conventional power plants and renewable energy systems, to consumers. As the electricity demand grows, the expansion of transmission infrastructure becomes essential to connecting new consumers with power suppliers. However, traditional transmission lines require significant right-of-way, posing challenges related to land use and environmental impact, as well as limited loadability. To address this issue, compact unconventional High Surge Impedance Loading (HSIL) transmission lines offer a viable solution by reducing right-of-way requirements while enhancing line natural power, mainly leading to less voltage drop. Before the implementation of the new unconventional HSIL lines, it is crucial to assess key parameters, such as magnetic field distribution under the lines, to ensure compliance with environmental and safety standards. This paper presents a numerical analysis of the magnetic field characteristics of compact unconventional HSIL transmission lines with different subconductor configurations. The results show that the proposed HSIL designs can reduce the magnetic field at ground level by up to 71.74% compared to a conventional 500 kV line near the center, as well as by up to 74% at the right-of-way edge, while maintaining magnetic field levels well below the limits set by ICNIRP and state-specific regulations. This study evaluates the magnetic field distribution within the right-of-way, providing insights into the electromagnetic performance and potential implications for transmission line design. Full article
Show Figures

Figure 1

19 pages, 4435 KB  
Article
Investigation of Electromagnetic Radiation Levels at DVB-T Transmission Points Operated by the Greek Public Broadcasting Service
by Konstantinos Zarkadas and George Dimitrakopoulos
Electronics 2025, 14(17), 3519; https://doi.org/10.3390/electronics14173519 - 3 Sep 2025
Viewed by 1198
Abstract
The increase in the popularity of digital terrestrial television broadcasting and the expansion of Greece’s network infrastructure have raised concerns about the possible harmful effects of exposure to long-term radio frequency electromagnetic fields (RF-EMFs) on sensitive groups. This study presents measurements of RF-EMFs [...] Read more.
The increase in the popularity of digital terrestrial television broadcasting and the expansion of Greece’s network infrastructure have raised concerns about the possible harmful effects of exposure to long-term radio frequency electromagnetic fields (RF-EMFs) on sensitive groups. This study presents measurements of RF-EMFs generated in three locations of digital terrestrial television broadcast stations of the national public broadcasting company of Greece. The measurements and calculations of the radio frequency (RF) electric-field strength and RF electromagnetic field (EMF) power density were carried out in the near-field and far-field regions of the antenna of a digital television broadcasting station. In these three locations, the results of real measurements were compared to reports by the Greek Atomic Energy Commission (EEAE) and the limit levels of International Commission on Non-Ionizing Radiation Protection (ICNIRP). Full article
Show Figures

Figure 1

20 pages, 4838 KB  
Article
Assessment of RF Electromagnetic Exposure to Car Driver from Monopole Array Antennas in V2V Communications Considering Thermal Characteristics
by Shirun Wang and Mai Lu
Sensors 2025, 25(10), 3247; https://doi.org/10.3390/s25103247 - 21 May 2025
Cited by 2 | Viewed by 1867
Abstract
Vehicles are rapidly evolving into objects of intelligent interconnection. Vehicle-to-Vehicle (V2V) communications enable the interconnection between vehicles, while also leading to new electromagnetic exposure scenarios. This paper integrates a monopole array antenna into a shark-fin antenna on the car roof for V2V communications [...] Read more.
Vehicles are rapidly evolving into objects of intelligent interconnection. Vehicle-to-Vehicle (V2V) communications enable the interconnection between vehicles, while also leading to new electromagnetic exposure scenarios. This paper integrates a monopole array antenna into a shark-fin antenna on the car roof for V2V communications and evaluates the specific absorption rate (SAR) and temperature rise of a human body in a smart mobility communication scenario operating at 5.9 GHz. The V2V antenna is modeled and placed on a 3D vehicle model using COMSOL Multiphysics (v.6.2) to numerically estimate the SAR in the head and body regions of the human body model (adult male) inside the vehicle. Both the localized and whole-body 30 min average SAR are lower than the International Commission on Non-Ionizing Radiation Protection (ICNIRP) occupational restrictions for electromagnetic field exposure from 100 kHz to 6 GHz, being equal in the worst-case scenario to 0.981 W/kg (for the head), which is 9.81% of the ICNIRP limit (10 W/kg), and 0.008728 W/kg (for the whole-body average), which is 2.18% of the ICNIRP limit (0.4 W/kg). The 30 min average human core temperature rise is 0.055 °C, which is 5.5% of the ICNIRP limit. This indicates that, in typical automotive scenarios, the electromagnetic exposure from a monopole array antenna for V2V communications does not pose threat to the human body. This study provides knowledge related to emerging exposure scenarios in intelligent mobility communication, which is beneficial for evaluating possible health impacts and designing public health management policies. Full article
(This article belongs to the Section Vehicular Sensing)
Show Figures

Figure 1

13 pages, 2219 KB  
Article
Worker Safety in High-Field NMR Spectroscopy Laboratories: Challenges and Risk Assessment
by Alessandra Flori, Giuseppe Acri, Maria Antonietta D’Avanzo, Massimo Mattozzi and Valentina Hartwig
Environments 2025, 12(4), 113; https://doi.org/10.3390/environments12040113 - 8 Apr 2025
Cited by 2 | Viewed by 3605
Abstract
Magnetic Resonance (MR) technology is extensively used in academic and industrial research laboratories and represents one of the most significant methodologies in clinical radiology. Although MR does not use ionizing radiation, it cannot be considered risk-free due to the strong static magnetic fields [...] Read more.
Magnetic Resonance (MR) technology is extensively used in academic and industrial research laboratories and represents one of the most significant methodologies in clinical radiology. Although MR does not use ionizing radiation, it cannot be considered risk-free due to the strong static magnetic fields and time-varying electromagnetic fields employed in the technology. To mitigate risks for MR operators, the European Community and ICNIRP have established safety limits based on the existing literature, primarily related to diagnostic MR. However, the literature on occupational exposure in non-clinical nuclear magnetic resonance (NMR) spectroscopy is limited. Due to their specificity, non-medical NMR environments present unique challenges from the point of view of operator exposure. NMR spectrometers are characterized by extremely high static magnetic fields, reaching up to 28 T in commercial systems; moreover, routine activities performed near the magnet, where field gradients are highest, increase operator exposure. Such environments are not typically perceived as hazardous and are frequented by various types of personnel, often without specific training. This study aims to highlight the critical issues in managing a preclinical MR laboratory equipped with a high-field NMR spectrometer, discussing operator safety challenges and presenting risk assessment data. Full article
Show Figures

Figure 1

20 pages, 8921 KB  
Article
A Survey of IEEE 802.11ax WLAN Temporal Duty Cycle for the Assessment of RF Electromagnetic Exposure
by Yizhen Yang, Günter Vermeeren, Leen Verloock, Mònica Guxens and Wout Joseph
Appl. Sci. 2025, 15(5), 2858; https://doi.org/10.3390/app15052858 - 6 Mar 2025
Cited by 2 | Viewed by 4683
Abstract
The increasing deployment of IEEE 802.11ax (Wi-Fi 6) networks necessitates an accurate assessment of radiofrequency electromagnetic field (RF-EMF) exposure under realistic usage scenarios. This study investigates the duty cycle (DC) and corresponding exposure levels of Wi-Fi 6 in controlled laboratory conditions, focusing on [...] Read more.
The increasing deployment of IEEE 802.11ax (Wi-Fi 6) networks necessitates an accurate assessment of radiofrequency electromagnetic field (RF-EMF) exposure under realistic usage scenarios. This study investigates the duty cycle (DC) and corresponding exposure levels of Wi-Fi 6 in controlled laboratory conditions, focusing on bandwidth variations, multi-user scenarios, and application types. DC measurements reveal significant variability across internet services, with FTP upload exhibiting the highest mean DC (94.3%) under 20 MHz bandwidth, while YouTube 4K video streaming showed bursts with a maximum DC of 89.2%. Under poor radio conditions, DC increased by up to 5× for certain applications, emphasizing the influence of degraded signal-to-noise ratio (SNR) on retransmissions and modulation. Weighted exposure results indicate a reduction in average electric-field strength by up to 10× when incorporating DC, with maximum weighted exposure at 4.2 V/m (6.9% of ICNIRP limits) during multi-user scenarios. These findings highlight the critical role of realistic DC assessments in refining exposure evaluations, ensuring regulatory compliance, and advancing the understanding of Wi-Fi 6’s EMF exposure implications. Full article
(This article belongs to the Special Issue Electromagnetic Radiation and Human Environment)
Show Figures

Figure 1

17 pages, 2091 KB  
Article
The Assessment of the Influence of Low-Frequency Electromagnetic Fields Originated from the Power Infrastructure on Humans’ Health
by Leszek Sławomir Litzbarski, Marek Olesz, Grzegorz Redlarski, Piotr Mateusz Tojza, Arkadiusz Żak, Emanuel Gifuni, Zuzanna Cieślikowska and Mieszko Czapliński
Appl. Sci. 2024, 14(21), 9668; https://doi.org/10.3390/app14219668 - 23 Oct 2024
Cited by 6 | Viewed by 4995
Abstract
The objective of this study is to assess the impact of low-frequency electromagnetic fields (LF EMFs) generated by power infrastructure on the nearby environment. Measurements of electric (E) and magnetic (H) field intensities were conducted around high-voltage power lines, [...] Read more.
The objective of this study is to assess the impact of low-frequency electromagnetic fields (LF EMFs) generated by power infrastructure on the nearby environment. Measurements of electric (E) and magnetic (H) field intensities were conducted around high-voltage power lines, transformer stations and facilities related to them. Numerical simulations were also performed to model the distribution of the field values around real buildings in close proximity to power delivery systems. Given the ongoing scientific debate regarding the effects of EMFs on living organisms, the current analysis was based on the existing standards—particularly ICNIRP 2010 guidelines, which set the maximum allowable E and magnetic induction (B) values at 5 kV/m and 200 μT, respectively. Stricter national regulations were also examined, such as Poland’s 1 kV/m E limit in residential areas and Belgium’s 10 μT limit for B. The results showed that while most cases complied with ICNIRP 2010 standards, certain stricter local regulations were exceeded. Specifically, 9 of 14 cases exceeded Poland’s E limits, and 8 failed to meet Belgium’s B requirements. Only in one place—a warehouse near 110 kV power lines (in a critical case)—the ICNIRP limit B was exceeded. These findings underscore the variability in regulatory standards and highlight the need for localized assessments of EMF exposure. Full article
Show Figures

Figure 1

15 pages, 4222 KB  
Article
Array of Active Shielding Coils for Magnetic Field Mitigation in Automotive Wireless Power Transfer Systems
by Silvano Cruciani, Tommaso Campi, Francesca Maradei and Mauro Feliziani
Energies 2024, 17(17), 4233; https://doi.org/10.3390/en17174233 - 24 Aug 2024
Cited by 5 | Viewed by 3260
Abstract
This paper deals with the mitigation of magnetic field levels produced by a wireless power transfer (WPT) system to recharge the battery of an electric vehicle (EV). In this work, an array of active coils surrounding the WPT coils is proposed as a [...] Read more.
This paper deals with the mitigation of magnetic field levels produced by a wireless power transfer (WPT) system to recharge the battery of an electric vehicle (EV). In this work, an array of active coils surrounding the WPT coils is proposed as a mitigation technique. The theory and new methodological aspects are the focus of the paper. Magnetic field levels in the environment are calculated numerically without and with the presence of an array of active coils in a stationary WPT system for automotive applications. By the proposed mitigation method, the field levels beside the vehicle are significantly reduced and comply with the reference levels (RLs) of the ICNIRP 2010 guidelines for human exposure to electromagnetic fields and the magnetic flux density limits proposed by ISO 14117 for electromagnetic interference (EMI) in cardiac implantable electronic devices (CIEDs). Full article
Show Figures

Figure 1

18 pages, 4733 KB  
Article
High Frequency Electromagnetic Field Exposure in Paediatric and Female Patients with Implanted Cardiac Pacemaker
by Frederika Bacova, Mariana Benova, Zuzana Psenakova, Milan Smetana, Miroslav Pacek and Jan Ochodnicky
Appl. Sci. 2024, 14(16), 7198; https://doi.org/10.3390/app14167198 - 15 Aug 2024
Cited by 3 | Viewed by 2037
Abstract
This article investigates the effects of electromagnetic field (EMF) from mobile phones on human tissues and implanted medical devices. The intensity of the electric field (E) is evaluated based on simulations and measurements of various exposure scenarios. An area of interest is the [...] Read more.
This article investigates the effects of electromagnetic field (EMF) from mobile phones on human tissues and implanted medical devices. The intensity of the electric field (E) is evaluated based on simulations and measurements of various exposure scenarios. An area of interest is the case of a person with an implanted device (heart pacemaker) who may be affected by this exposure. Due to the rapid development of communication technologies and the growing awareness of the potential health risks of radio frequency (RF) EMF, the International Commission on Non-Ionizing Radiation Protection (ICNIRP) has established exposure limits within the European Union. Our study models and analyses EMF values in human tissues in an ideal environment, in a situation where a person uses a mobile phone in the DCS (Digital Cellular System) band, including the case of a person with an implanted pacemaker. Pilot simulations were verified by experimental measurements. Based on them, specific human models with the best matching results were selected for modelling other possible interactions of exogenous EMF and cardiac pacemaker in the same situations and locations. Full article
Show Figures

Figure 1

18 pages, 10601 KB  
Article
A Compact Wearable Textile Antenna for NB-IoT and ISM Band Patient Tracking Applications
by Deepti Sharma, Rakesh N. Tiwari, Sachin Kumar, Satyendra Sharma and Ladislau Matekovits
Sensors 2024, 24(15), 5077; https://doi.org/10.3390/s24155077 - 5 Aug 2024
Cited by 35 | Viewed by 5503
Abstract
This paper proposes a novel multi-band textile monopole antenna for patient tracking applications. The designed antenna has compact footprints (0.13λ02) and works in the narrow band-internet of things (NB-IoT) 1.8 GHz, radio frequency identification (RFID), and industrial, scientific, and [...] Read more.
This paper proposes a novel multi-band textile monopole antenna for patient tracking applications. The designed antenna has compact footprints (0.13λ02) and works in the narrow band-internet of things (NB-IoT) 1.8 GHz, radio frequency identification (RFID), and industrial, scientific, and medical (ISM) 2.45 GHz and 5.8 GHz bands. The impedance bandwidths and gain of the antenna at 1.8 GHz, 2.45 GHz, and 5.8 GHz are 310 MHz, 960 MHz, and 1140 MHz; 3.7 dBi, 5.3 dBi, and 9.6 dBi, respectively. Also, the antenna’s behavior is checked on different body parts of the human body in various bending scenarios. As per the evaluated link budget, the designed antenna can easily communicate up to 100 m of distance. The specific absorption rate values of the designed antenna are also within acceptable limits as per the (FCC/ICNIRP) standards at the reported frequency bands. Unlike traditional rigid antennas, the proposed textile antenna is non-intrusive, enhancing user safety and comfort. The denim material makes it comfortable for extended wear, reducing the risk of skin irritation. It can also withstand regular wear and tear, including stretching and bending. The presented denim-based antenna can be seamlessly integrated into clothing and accessories, making it less obtrusive and more aesthetically pleasing. Full article
(This article belongs to the Section Biomedical Sensors)
Show Figures

Figure 1

Back to TopTop