Article

Using Triangular Gate Voltage Pulses to Evaluate Hysteresis and Charge Trapping Effects in GaN on Si HEMTs

Solid State Electronics Technology (SET) Laboratory, Department of Engineering, University of Palermo, 90127 Palermo, Italy
*
Author to whom correspondence should be addressed.
Electronics 2025, 14(10), 1991; https://doi.org/10.3390/electronics14101991
Submission received: 16 April 2025 / Revised: 7 May 2025 / Accepted: 12 May 2025 / Published: 13 May 2025

Abstract

:
Charge carrier traps due to crystal defects in GaN on Si HEMT devices are responsible for dynamic performance degradation, long-term reliability limitations, and peculiar failure modes. The behavior of traps depends on many variables including heterostructure quality, the specific device structure, and operating conditions. To study the short time dynamics of charge trapping and release on the threshold voltage shift and hysteresis of commercial normally off GaN HEMTs we use triangular 0–5 V gate voltage pulses in the μs to ms duration range. Measurements are performed for single pulses by varying pulse duration and for a train of a few pulses by varying their number. The results indicate that hysteresis and related threshold voltage shift occur after repeated pulses, suggesting an accumulation of trapped charges. However, for a triangular wave hysteresis vanishes, meaning that a dynamic balance between charge trapping and release is established in the device. This can be considered as a positive indicator of device robustness and reliability. The same method, used to measure the gate threshold voltage shift and dynamic RON after a 30 min off-state DC stress at VDS = 55 V with a floating gate, highlights an appreciable performance degradation of the device.

1. Introduction

In recent years, gallium nitride (GaN)-based high-electron-mobility transistors (HEMTs) [1] have emerged as a key technology in power electronics and RF communications due to GaN’s unique combination of physical properties, such as a wide bandgap (3.4 eV), high electron saturation velocity, and excellent thermal conductivity. These attributes make GaN HEMTs particularly suited for high-temperature, high-voltage applications, including high-power switching converters where they offer low power losses and fast switching speeds.
Due to the lack of suitable substrates and to exploit the advantages given by integration, GaN is grown on (111) Si, whose orientation is the closest to the hexagonal wurtzite crystal structure of GaN [2]. Moreover, Si is much cheaper than other substrate materials such as sapphire or SiC. The different lattice constant of Si as compared to GaN gives quite a big lattice mismatch of 17% [2]. For this reason, a buffer layer is needed to reduce crystal defects formation, as an example an AlN nucleation layer followed by an AlN/GaN superlattice is often adopted among several possible solutions [3]. Whatever the solution used for the buffer layer, crystal defects are formed at different locations in the heterostructure. They act as traps for charge carriers, as shown schematically in Figure 1 for a normally off p-GaN gate HEMT [4], and are responsible for degrading device performance and limiting long-term reliability.
Charge trapping occurs when carriers, such as electrons or holes, are captured by defect states at free surfaces, interfaces, or within the semiconductor layers themselves [5]. These trapping states can be due to structural defects, contamination during fabrication, or created from electrical and thermal stress during device operation [6]. Trapped electrons under the gate, both in the barrier (due to the small leakage gate current) and in the GaN buffer layer underneath the two-dimensional electron gas (2DEG) channel (due to channel depletion in the OFF state), can shift the threshold voltage (VTH) of the GaN HEMT. This shift can manifest itself as a hysteresis in the drain current vs. gate voltage relationship, as measured by using a triangular gate voltage pulse where VGS is first swept forward (rising) and then backward (falling) [7]. In a switching operation, hysteresis refers to a variation in the threshold voltage among switching cycles.
Understanding charge trapping and release dynamic mechanisms is critical for ensuring long-term reliability and performance stability. Moreover, failure modes of GaN HEMT devices during accelerated lifetime tests [8,9] are determined by traps [10] in contrast to standard power Si MOSFETs that are almost ideal. This study investigates hysteresis and threshold voltage shifts in GaN HEMTs by applying single and multiple triangular gate voltage pulses with a duration ranging from 1 µs to 10 ms to pristine devices, and to devices that undergo an extended time DC off-state stress test. The results indicate that for single pulses the VTH shifts with associated hysteresis depend on pulse duration i.e., VGS sweeping rate, whilst for a few pulse trains the VTH shifts change with pulse number and hysteresis occurs after the first few repeated pulses, suggesting an accumulation of trapped charges. However, for extended time operation, i.e., with a triangular wave, hysteresis vanishes because a dynamic balance between charge trapping and release is reached. The presented results give useful insights into the short timescale dynamic and steady-state behavior of VTH shift and hysteresis during a soft switching operation.

2. Materials and Methods

The circuit used for the measurements, shown in Figure 2, use a commercial normally off power GaN HEMT device produced by ST (SGT120R65AL, 650 V, VTH = 1.8 V typ., DC RON = 75 mΩ typ., 15 A) operated in switching mode with a resistive load. The nominal switched drain current is set by choosing appropriate values for VDD and RD. For practical convenience, the circuit is implemented on a breadboard, ensuring the wire connections are as short as possible to minimize parasitic effects. A photo of the experimental setup for the measurements is shown in Figure 3.
The voltages across the gate and drain resistors, whose value is accurately measured in advance, are acquired by a four channels digital oscilloscope (Tektronix MSO54) through 1X accurately compensated probes. The triangular gate 0–5 V voltage pulses, with a duration ranging from 1 µs to 10 ms, are obtained through an arbitrary waveform generator (Tektronix AFG 31000 series or a Digilent analog discovery 2 multi-function programmable board). Relevant voltages together with the drain current ID = (VDD − VDS)/RD and the dynamic RON = VDS/ID waveforms are shown in Figure 4 for a single triangular pulse of 10 µs duration. A triangular gate voltage pulse drives the device under a soft switching operation, as evidenced by the lack of drain current oscillations during the falling edge. It is worth noticing the non-specular shape of the rising and falling edges of ID, a signature of the presence of charge trapping effects.
Polypropylene low-ESR capacitors (30 µF together with 10 µF and 3 µF) are connected in parallel between the power supply (LABPS23023 variable 0–60 V/0–6 A) voltage and ground for frequency compensation of its output impedance. This is necessary because, as shown in Figure 5 for nominal 24 V, we observe a drop in the output voltage of the power supply during device fast switching to the on state, where current sourcing is required. This occurs because during the response to a step current load, analog power supplies exhibit higher resistance than in DC because negative feedback is mostly ineffective, limiting the speed at which the current can change during fast switching events [11]. Figure 5 shows that with the shunt low-ESR capacitors the power supply voltage drop disappears almost completely.
The 330 Ω gate resistor is used to limit the current required to the gate driver, in our case the analog output WaveGen of the analog discovery 2 board, which has a recommended output current of 10 mA at ± 5 V and a maximum absolute rating of 50 mA at ± 5.8 V. The value of this resistor is chosen to achieve a good trade-off between the gate charge/discharge peak current required to the driver and the fast switching time of the GaN HEMT in response to a rectangular gate voltage. We check in advance that even for a rectangular pulse duration of 1 μs the drain current can reach its regime value [12]. This has also been double-checked using an LTspice XVII software simulation of the circuit using the spice model of the device provided by the manufacturer.
As we are interested in measuring small voltages in the hundreds of mV range, such as the VDS during the on state of the device, and so the oscilloscope is set to high-resolution mode, exploiting the maximum available bit dept (16 bits). Furthermore, to reduce noise, the bandwidth is limited for all four channels of the oscilloscope.
Before each measurement, the gate and drain terminals of the device are shorted to ground for two minutes to release any trapped charge leftover from the previous measurement and re-establish pristine condition, avoiding the presence of any form of ‘memory effect’.
The HEMT under test has a typical threshold voltage of 1.8 V and a maximum VGS of 7 V, hence, to drive it deeply into the ohmic region the gate is driven by triangular 0–5 V voltage pulses of different duration. These are single pulses, a train of a few pulses, and a triangular wave, aiming at monitoring hysteresis and VTH shift evolution from short to extended time intervals. The method allows for a detailed investigation of the dynamics of charge trapping and release and its influence on the threshold voltage shift. The same method is used to assess threshold voltage shifts after DC stressing the device in the off state for 30 min.
The plot of ID vs. VGS shows the possible presence of hysteresis, and the threshold voltage shift ∆VTH is determined as the difference in VGS values corresponding to ID = 10 mA during the rising and falling edges of the drain current. The values of ∆VTH and its sign give an indication of how the device accumulates or releases trapped charges under the gate heterojunction from material defects or interfaces between semiconductor layers.
To further study the initial transient behavior of the device a train of a few triangular VGS pulses is used. This allows us to examine how the device responds to repeated pulses, and if and how hysteresis evolves with pulse number and charge accumulation. Moreover, important information can be drawn by comparing the response to a pulse train with the one to a single triangular pulse of duration equal to the pulse train. Finally, to complete the study a triangular VGS waveform is also applied to evaluate long time dynamic steady-state hysteresis behavior.
As part of the device robustness evaluation, VTH and RON are also evaluated after prolonged DC off-state stress tests to assess the possible presence of residual surface and interface traps in the drain access region and the device’s ability to maintain operational performance after prolonged time electrical stress.

3. Results and Discussion

In actual devices, crystal defects and traps spatial distribution are not uniform and can change among devices. This can give different results for the actual numbers of hysteresis and threshold voltage shift. However, our measurements on several SGT120R65AL devices confirm that the general trend is well reproduced. For this reason and for consistency, the reported results are for the same single device. The voltage measurement errors can be assumed to be 5%, but for better clarity they are not indicated in the graphs.
The ID vs. VGS for the rising edge of single triangular pulses of increasing duration and for a nominal drain current of ID =100 mA is reported in Figure 6. A reduction in threshold voltage VTH is observed for longer pulse durations, suggesting the occurrence of reduced charge trapping (or increased charge release) under the gate of the GaN HEMT device.
In GaN HEMTs, charges can be trapped in defects introducing localized deep states within the bandgap of the semiconductor materials, in the bulk, or at the interface between different layers (e.g., the p-GaN/AlGaN barrier). When longer pulses are applied, the vertical electric field under the gate is applied for a longer time and this may help the release of trapped electrons in the p-GaN/AlGaN barrier originating from the very small gate leakage current flowing. Hence, the vertical electric field screening is reduced, and for the same channel conductivity, i.e., drain current, a smaller VGS is required. The corresponding simultaneous increase in the large signal dynamic transconductance gm is also indicative of a reduced dynamic current collapse, as shown in Figure 6.
The threshold voltage shift ∆VTH = VGS_UP − VGS_DOWN as a function of pulse duration is reported in Figure 7 for the case ID = 350 mA. The interesting feature highlighted by the graph is that the shift is negative and quite big for 1 µs pulse duration and then for longer pulses it becomes positive (apart from the 100 µs point) and much smaller. It can be said that ∆VTH is positive or negative depending on the pulse duration.
This behavior can be linked to a higher concentration of trapped electrons under the gate for shorter pulses that more effectively screen the gate voltage during the falling edge, in agreement with the rising edge seen in ID vs. VGS in Figure 6. In fact, for the same applied VGS a negative variation in VTH results in a higher ID (which could damage the device), while a positive variation decreases the drain current, increasing conduction resistance and negatively impacting switching times.
To further study the dynamics of VTH variations the response of the device to a train of a few triangular pulses is measured. First, a train of four triangular voltage pulses with a pulse duration of 250 µs is applied, hence a train duration of 1 ms, and the circuit parameters are set for ID = 350 mA. The analysis of ID vs. VGS for each triangular pulse reveals that hysteresis does not occur right after the first pulse but becomes evident starting from the third pulse and becomes bigger for the fourth pulse, as shown in Figure 8.
This behavior can be explained for multiple pulses by the fact that during each on to off transition electrons in the channel are pushed towards the GaN buffer layer where they become trapped by bulk traps. When the device is driven back to the on-state by the next pulse of the train, these trapped electrons act as a “back gate” with negative bias, decreasing population in the 2DEG channel as compared to its equilibrium concentration and causing the VTH shift under the gate [13,14,15]. Bulk traps in the GaN buffer layer can be assumed to be distributed in the whole device active area; hence, the “back gate” is extended in the gate-to-drain region as well, and this leads also to dynamic RON and gm change [16].
If the response to a single triangular pulse of duration equal to the one of the four pulses train (i.e., 1 ms) is evaluated, the hysteresis in VGS is almost negligible, as shown in Figure 9. This highlights how the application of a pulse train influences charge trapping in the buffer layer under the channel through a cumulative effect.
The slow electric field-assisted charge release dynamics are a key factor in explaining this behavior. If charge release mechanisms are slower than the pulse frequency, trapped charges accumulate over time, altering the internal electric field of the device and inducing hysteresis. This suggests that the device accumulates trapped charges across multiple switching cycles, and beyond a certain threshold hysteresis becomes evident. The absence of hysteresis during the first pulse of the train could indicate that the trapping process is associated with slow activation mechanisms or the progressive saturation of specific trapping states [17].
A further test, conducted by applying a train of 10 triangular VGS pulses with a pulse duration of 100 µs, again for a train duration of 1 ms, suggests a progressive accumulation of trapped charges with pulse number. This is shown in Figure 10, where the hysteresis in VGS is reported for the fifth and tenth pulse.
The results show no significant hysteresis after the first few pulses, but as the pulse number progresses, particularly for the tenth pulse (the last one), a notable increase in hysteresis is observed, indicating substantial trapped electrons accumulation in the GaN buffer layer under the channel. It is important to note that the hysteresis at the tenth pulse (∆VTH = −1.42 V) is greater than that at the fourth pulse in the four-pulse train (∆VTH = −0.69 V). This confirms that hysteresis increases for a pulse train with a higher number of pulses.
Subsequently, a train of 10 longer triangular pulses with a pulse duration of 200 µs, for a train total duration of 2 ms, is applied and the device exhibits a similar trend, as reported in Figure 11. This suggests that the hysteresis phenomenon is primarily related to the progressive trapping of charges rather than just the pulse train period.
To investigate the release dynamics of trapped electrons in the buffer and barrier layer under the gate in the off-state we perform an additional test by driving the device with a train of 10 pulses, each with a period of 100 µs, followed by an off-state time interval of 100 µs and then a single 100 µs probe pulse.
As we can see from Figure 12, where the hysteresis of the tenth pulse and the one of the probe pulse are reported, the significant hysteresis of the tenth pulse has almost completely vanished after an off time of 100 µs, as measured by the probe pulse. Therefore, the 100 µs off time interval is sufficient to allow for the complete release of trapped electrons from the traps in the buffer and barrier layers under the gate.
For a shorter off-state time interval of 10 µs, hysteresis is observed for both the tenth pulse of the train and the probe pulse after the off-state time, as shown in Figure 13. This indicates that 10 µs is not a sufficient time interval for complete release and that residual trapped charges are still present under the gate. For the operating conditions under which the test is carried out, we can say that the average release time of trapped charges under the gate is at most 100 µs.
It is also interesting to note from Figure 13b that the hysteresis for the probe pulse has a positive shift in the threshold voltage, even though for all the preceding pulses of the train the shift is always negative. The explanation for this behavior can be as follows. The contribution to VTH or VGS shift can be twofold: (i) electrons trapped in the barrier under the gate giving a positive shift because of their screening bias effect for the positive VGS and (ii) electrons trapped in the GaN buffer layer under the channel giving a positive shift of VGS because they act as a back gate with negative bias. For an off time interval of 10 µs the release of trapped electrons under the gate is incomplete and it continues during the application of the probe pulse itself, resulting in the falling edge of the probe pulse experiencing a lower concentration of trapped electrons in respect to its rising edge, hence, the lower VTH and VGS for the same drain current.
A triangular wave driving the gate voltage can give an indication of hysteresis behavior at much longer times that we refer to as dynamic steady-state. In this case, the device behavior is monitored after a time interval of 1, 10, and 30 min from the application of the triangular wave gate voltage with pulse duration 1 ms, 100 µs, and 10 µs, corresponding to a repetition frequency, respectively, of 100 Hz, 1 kHz, and 10 kHz. The result shown in Figure 14 is for the measurement taken after 1 min with 100 µs pulse duration and nominal ID = 350 mA.
The primary observed result is that after 1 min there is no hysteresis and no significant threshold voltage shift. In fact, a difference smaller than 100 mV in VTH can be considered negligible as compared to a VTH = 1.4 V exhibited by the device in the specific operating conditions. In our case, this gives rising and falling edges of ID vs VGS very close one to each other. This behavior suggests that the device reaches a dynamic equilibrium between charge trapping and release both in the barrier layers under the gate and in the buffer layer under the channel, stabilizing the threshold voltage and limiting significant drain current variation over time.
Another relevant observation concerns the maximum ID of 340 mA achieved, which is smaller than the nominal 350 mA value expected. Moreover, the slope of the ID vs. VGS rising and falling edge, which is indicative of the large signal dynamic transconductance gm, is less steep, i.e., the gm is reduced compared to the slope of the hysteresis graphs obtained with equivalent single pulses. Both of these results can be considered as a small dynamic current collapse attributed to trapped charges in the barrier layers under the gate and in the GaN buffer layer under the channel.
An important observation is that the VTH value of 1.5 V from Figure 14 is higher than the VTH value of the first (single) pulse from Figure 8a, that is 1.23 V. In fact, the triangular wave is applied for a longer time interval, such as 1 min or more, and dynamic equilibrium between trapped and released charge carriers is reached, gradually eliminating the hysteresis. The increased VTH value to 1.5 V is because the internal electric field due to trapped charges counteracts the external one due to the applied VGS. The VTH for a single pulse is lower because the device has not yet reached dynamic equilibrium in the trapping and release processes under the gate. This long-term dynamic steady-state equilibrium behavior can be interpreted as a positive indicator of device reliability.
In other words, when the device reaches this dynamic steady-state the traps in the semiconductor layers under the gate are either fully occupied by electrons or a balance in the trapping and release processes at each cycle is reached.
To further study the reliability of the device off-state, stress tests are carried out with a drain voltage of 55 V applied to the device for 1 min, 10 min, and 30 min, with the gate either short-circuited to ground or left floating. The small off-state leakage drain current flowing is supposed to promote charge trapping at the surface or interface traps of the p-GaN/AlGaN barrier in the gate-to-drain region [18]. This gives an increase in VTH and RON and a decrease in gm, indicating a degraded channel conduction due to trapped charges in the drain access region [14]. These off-state stress tests are non-destructive and repeatable with no creation of permanent defects, for example, those caused by the inverse piezoelectric effect at very high VDS when applied even for relatively short times [19,20,21]. Immediately after each stress test the device is probed with a single 10 µs triangular pulse to measure VTH and RON.
In the configuration with the gate short-circuited, negligible variations were observed for the stressed device compared to the pristine device. In fact, with the grounded gate the electric field at the drain side of the gate is zero. On the contrary, with the gate left floating the horizontal electric field generated by VDS is the maximum and can induce charge trapping in the barrier region between the gate and drain. In this case, 1 min and 10 min off-state stress durations give no appreciable difference with a pristine device. On the contrary, after 30 min the stressed device exhibits an appreciable performance degradation, as shown in Figure 15.
Comparing Figure 15a,b, an increase in the VTH from 1.2 V to about 1.5 V is evident for the stressed device, together with a decrease in the transconductance gm that is the slope of the ID vs. VGS relationship. Moreover, hysteresis shows up for both pristine and stressed devices. For this kind of stress test, traps at different locations in the device contribute to the observed behavior. The RON reported in Figure 15c for the stressed device increases by about 25% compared to the one for the pristine device, suggesting a degraded channel current conduction efficiency or/and an increased drain side access resistance due to the trapped charges in the barrier layers and interfaces in the gate to drain region [22,23]. This effect may be even stronger for larger off-state VDS voltages because of the increased electric field.
A longer switching delay in the off-to-on transition, as indicated by the blue trace being fully inside the red one in Figure 15c, is also evident. This implies that the stressed device requires more time to reach full conduction in response to the same applied gate voltage. This delay is likely associated with increased input and output capacitance due to the internal electric potential distribution that is modified by the charges trapped in the gate-to-drain access region.

4. Conclusions

This study demonstrates that charge trapping under the gate of GaN HEMT devices is a dynamic phenomenon that evolves over time and, for switching operations, through multiple switching cycles. By using triangular voltage gate pulses, hysteresis of ID vs. VGS appears only after a few repeated triangular gate pulses and the device reaches dynamic equilibrium between the trapping and release of charge carriers under the gate after 1 min of prolonged switching operation. Our results with trains of 4 or 10 triangular pulses indicate that hysteresis builds up through a progressive accumulation of trapped charges, influenced by semiconductor layers and interfaces quality and by the switching cycle duration. The results of the off-state stress test with a floating gate show that charge trapping in the drain access region takes place, leading to significant RON degradation, together with an increase in VTH and a decrease in gm. In summary, reliability and performance stability of GaN on Si HEMT devices for high-frequency and power applications can be improved by a reduction in defects and traps concentration. The absence of hysteresis after prolonged operation with triangular wave gate voltage suggests that the GaN HEMT device under study can achieve long-term operational stability, reducing the risk of threshold voltage instability which could compromise the efficiency and precision of circuits and systems utilizing these devices, such as high-power switching converters.

Author Contributions

Conceptualization, P.C., F.V., and A.S.; methodology, P.C., F.V., and A.S.; software, F.V. and A.S.; investigation, P.C., F.V., and A.S.; writing—original draft preparation, P.C., F.V., and A.S.; writing—review and editing, P.C., F.V., and A.S.; supervision, P.C. All authors have read and agreed to the published version of the manuscript.

Funding

F. Vella and A. Sirchia acknowledge funding in the framework of the European Project “GaN4AP: GaN for Advanced Power Applications” under grant agreement No. PRJ-1035–CUP B73C21001310003. Work was carried out in the framework of the European Project “GaN4AP: Gallium Nitride for Advanced Power Applications”.

Data Availability Statement

The original contributions presented in the study are included in the article. Further inquiries can be directed to the corresponding author.

Acknowledgments

The authors acknowledge G. Artale and A. Sferlazza for providing some of the instrumentation used for the measurements and N. Campagna for the realization of the surface mount to through hole adapter boards.

Conflicts of Interest

The authors declare no conflicts of interest.

Abbreviations

The following abbreviations are used in this manuscript:
HEMTHigh-Electron-Mobility Transistor
2DEGTwo-Dimensional Electron Gas
VGS_UPRising Edge Threshold Voltage
VGS_DOWNFalling Edge Threshold Voltage
RONDynamic Conduction Resistance
gmDynamic Transconductance
VTHThreshold Voltage
∆VTHThreshold Voltage Shift

References

  1. Meneghini, M.; De Santi, C.; Abid, I.; Buffolo, M.; Cioni, M.; Khadar, R.A.; Nela, L.; Zagni, N.; Chini, A.; Medjdoub, F.; et al. GaN-based power devices: Physics, reliability, and perspectives. J. Appl. Phys. 2021, 130, 181101. [Google Scholar] [CrossRef]
  2. Scholz, F.; Bockowski, M.; Grzanka, E. GaN-Based Materials: Substrates, Metalorganic Vapor-Phase Epitaxy, and Quantum Well Properties. In Nitride Semiconductor Technology; Roccaforte, F., Leszczynski, M., Eds.; Wiley-VCH: Weinheim, Germany, 2020; pp. 41–98. [Google Scholar]
  3. Zhang, B.; Liu, Y. A review of GaN-based optoelectronic devices on silicon substrate. Chin. Sci. Bull. 2014, 59, 1251–1275. [Google Scholar] [CrossRef]
  4. Roccaforte, F.; Greco, G.; Fiorenza, P.; Iucolano, F. An Overview of Normally-Off GaN-Based High Electron Mobility Transistors. Materials 2019, 12, 1599. [Google Scholar] [CrossRef] [PubMed]
  5. Trew, R.; Green, D.; Shealy, J. AlGaN/GaN HFET reliability. IEEE Microw. Mag. 2009, 10, 116–127. [Google Scholar] [CrossRef]
  6. Meneghesso, G.; Meneghini, M.; Bisi, D.; Zanoni, E. Trapping phenomena in AlGaN/GaN HEMTs: A study based on pulsed and transient measurements. Semicond. Sci. Technol. 2013, 28, 074021-1–074021-8. [Google Scholar] [CrossRef]
  7. Faqir, M.; Verzellesi, G.; Fantini, F.; Meneghesso, G.; Zanoni, E. Characterization and analysis of trap-related effects in AlGaN–GaN HEMTs. Microelectron. Reliab. 2007, 47, 1639–1642. [Google Scholar] [CrossRef]
  8. Meneghini, M.; Tajalli, A.; Moens, P.; Banerjee, A.; Zanoni, E.; Meneghesso, G. Trapping phenomena and degradation mechanisms in GaN-based power HEMTs. Mater. Sci. Semicond. Process. 2018, 78, 118–126. [Google Scholar] [CrossRef]
  9. Rauf, F.; Tayyab, M.F.; Mouhoubi, S.; Heldwein, M.L.; Curatola, G. Investigation of the long-term dynamic RDS(on) variation and dynamic high temperature operating life test robustness of Schottky gate and ohmic gate GaN HEMT with comparable stress conditions. Microelectron. Reliab. 2025, 168, 115708. [Google Scholar] [CrossRef]
  10. Nautiyal, P.; Pande, P.; Kundu, V.S.; Moghadam, H.A. Trap-assisted degradation mechanisms in E-mode p-GaN power HEMT: A review. Microelectr. Reliab. 2022, 139, 114800. [Google Scholar] [CrossRef]
  11. Understanding Power Impedance Supply for Optimum Decoupling, Appl. Note 3. Available online: https://calex.com/pdf/3power_impedance.pdf (accessed on 15 April 2025).
  12. Cusumano, P.; Sirchia, A.; Vella, F. Evaluation of dynamic ON resistance and trapping effects in GaN on Si HEMTs using rectangular gate voltage pulses. Electronics, 2025; submitted. [Google Scholar]
  13. Tapajna, M.; Jimenez, J.L.; Kuball, M. On the discrimination between bulk and surface traps in AlGaN/GaN HEMTs from trapping characteristics. Phys. Status Solidi A 2012, 209, 386–389. [Google Scholar] [CrossRef]
  14. Zhang, W.; Liu, X.; Fu, L.; Zhang, J.; Zhao, S.; Hao, Y. Investigation of threshold voltage shift and gate leakage mechanisms in normally off AlN/Al0.05Ga0.95N HEMTs on Si substrate. AIP Adv. 2020, 10, 115015. [Google Scholar] [CrossRef]
  15. Pengfei, D.; Shaowei, W.; Hongliang, L. Research on the Reliability of Threshold Voltage Based on GaN High-Electron-Mobility Transistors. Micromachines 2024, 15, 321. [Google Scholar] [CrossRef]
  16. Tapajna, M.; Koller, C. Reliability Issues in GaN Electronic Devices. In Nitride Semiconductor Technology; Roccaforte, F., Leszczynski, M., Eds.; Wiley-VCH: Weinheim, Germany, 2020; pp. 199–241. [Google Scholar]
  17. Joh, J.; del Alamo, J.A. A Current-Transient Methodology for Trap Analysis for GaN High Electron Mobility Transistors. IEEE Trans. Electron Dev. 2011, 58, 132–140. [Google Scholar] [CrossRef]
  18. Tapajna, M.; Simms, R.J.T.; Pei, Y.; Kuball, M. Integrated optical and electrical analysis: Identifying location and properties of traps in AlGaN/GaN HEMTs during electrical stress. IEEE Electron Device Lett. 2010, 31, 662–664. [Google Scholar] [CrossRef]
  19. Yao, Z.; Zhu, H.; Li, Y.; Xie, N.; Sun, Y.; Zhang, Y.; Liu, X.; Zhang, Z. Investigation of trap characteristics under the inverse piezoelectric effect in AlGaN/GaN HEMT devices at room temperature and low temperature. Semicond. Sci. Technol. 2023, 38, 055008. [Google Scholar] [CrossRef]
  20. Bisi, D.; Meneghini, M.; De Santi, C.; Chini, A.; Dammann, M.; Bruckner, P.; Mikulla, M.; Meneghesso, G.; Zanoni, E. Deep-level characterization in GaN HEMTs-Part I: Advantages and limitations of drain current transient measurements. IEEE Trans. Electron Devices 2013, 60, 3166–3175. [Google Scholar] [CrossRef]
  21. Meneghini, M.; Rossetto, I.; De Santi, C.; Rampazzo, F.; Tajalli, A.; Barbato, A.; Ruzzarin, M.; Borga, M.; Canato, E.; Zanoni, E.; et al. Reliability and failure analysis in power GaN-HEMTs: An overview. In Proceedings of the IEEE International Reliability Physics Symposium (IRPS) 2017, Monterey, CA, USA, 2–6 April 2017. [Google Scholar] [CrossRef]
  22. Canato, E.; Meneghini, M.; De Santi, C.; Masin, F.; Stockman, A.; Moens, P.; Zanoni, E.; Meneghesso, G. OFF-state trapping phenomena in GaN HEMTs: Interplay between gate trapping, acceptor ionization and positive charge redistribution. Microelectron. Reliab. 2020, 114, 113841. [Google Scholar] [CrossRef]
  23. Nardo, A.; De Santi, C.; Koller, C.; Ostermaier, C.; Daumiller, I.; Meneghesso, G.; Zanoni, E.; Meneghini, M. Positive and negative charge trapping GaN HEMTs: Interplay between thermal emission and transport-limited processes. Microelectron. Reliab. 2021, 126, 114255. [Google Scholar] [CrossRef]
Figure 1. Schematic representation of surface and bulk traps in a normally off p-GaN HEMT affecting threshold voltage VTH, dynamic RON and transconductance gm.
Figure 1. Schematic representation of surface and bulk traps in a normally off p-GaN HEMT affecting threshold voltage VTH, dynamic RON and transconductance gm.
Electronics 14 01991 g001
Figure 2. Circuit schematic used for measurements.
Figure 2. Circuit schematic used for measurements.
Electronics 14 01991 g002
Figure 3. Experimental setup used for measurements. (1) LABPS23023 power supply, (2) Digilent analog discovery 2 multi-function programmable board, (3) Tektronix MSO54 digital oscilloscope, (4) breadboard with the measurement circuit and probes, and (5) PC with Waveforms 2 software program to generate triangular pulses.
Figure 3. Experimental setup used for measurements. (1) LABPS23023 power supply, (2) Digilent analog discovery 2 multi-function programmable board, (3) Tektronix MSO54 digital oscilloscope, (4) breadboard with the measurement circuit and probes, and (5) PC with Waveforms 2 software program to generate triangular pulses.
Electronics 14 01991 g003
Figure 4. Waveforms of oscilloscope voltages (from top to bottom VDS, VGEN, VGS, and VDD), drain current ID, and RON corresponding to a triangular voltage pulse of 10 µs duration. The horizontal time scale is 1 μs/div.
Figure 4. Waveforms of oscilloscope voltages (from top to bottom VDS, VGEN, VGS, and VDD), drain current ID, and RON corresponding to a triangular voltage pulse of 10 µs duration. The horizontal time scale is 1 μs/div.
Electronics 14 01991 g004
Figure 5. Power supply voltage drops during the on current drain conduction with and without compensating low-ESR polypropylene capacitors.
Figure 5. Power supply voltage drops during the on current drain conduction with and without compensating low-ESR polypropylene capacitors.
Electronics 14 01991 g005
Figure 6. ID (nominal 100 mA) rising edge vs. VGS for single triangular pulses of increasing duration.
Figure 6. ID (nominal 100 mA) rising edge vs. VGS for single triangular pulses of increasing duration.
Electronics 14 01991 g006
Figure 7. Threshold voltage shift ∆VTH between rising and falling edges for a single triangular pulse as a function of pulse duration.
Figure 7. Threshold voltage shift ∆VTH between rising and falling edges for a single triangular pulse as a function of pulse duration.
Electronics 14 01991 g007
Figure 8. Response to a train of 4 pulses of 250 μs duration each (a) VGS_UP and VGS_DOWN, (b) ∆VTH, and (c) hysteresis of ID vs. VGS of the fourth pulse.
Figure 8. Response to a train of 4 pulses of 250 μs duration each (a) VGS_UP and VGS_DOWN, (b) ∆VTH, and (c) hysteresis of ID vs. VGS of the fourth pulse.
Electronics 14 01991 g008
Figure 9. Hysteresis of ID vs. VGS for a single pulse with a 1 ms duration.
Figure 9. Hysteresis of ID vs. VGS for a single pulse with a 1 ms duration.
Electronics 14 01991 g009
Figure 10. Response to a train of 10 pulses of 100 μs duration each (a) VGS_UP and VGS_DOWN, (b) ∆VTH, and (c) hysteresis of ID vs. VGS of the 10th pulse.
Figure 10. Response to a train of 10 pulses of 100 μs duration each (a) VGS_UP and VGS_DOWN, (b) ∆VTH, and (c) hysteresis of ID vs. VGS of the 10th pulse.
Electronics 14 01991 g010
Figure 11. Response to a train of 10 pulses of 200 μs duration each (a) VGS_UP and VGS_DOWN, (b) ∆VTH, and (c) hysteresis of ID vs. VGS of the 10th pulse.
Figure 11. Response to a train of 10 pulses of 200 μs duration each (a) VGS_UP and VGS_DOWN, (b) ∆VTH, and (c) hysteresis of ID vs. VGS of the 10th pulse.
Electronics 14 01991 g011
Figure 12. Hysteresis of ID vs. VGS for a train of ten pulses, each with a period of 100 µs, followed by an off-state time of 100 µs and then a single 100 µs probe pulse (a) of the tenth pulse, and (b) of the probe pulse after 100 µs off-state time.
Figure 12. Hysteresis of ID vs. VGS for a train of ten pulses, each with a period of 100 µs, followed by an off-state time of 100 µs and then a single 100 µs probe pulse (a) of the tenth pulse, and (b) of the probe pulse after 100 µs off-state time.
Electronics 14 01991 g012
Figure 13. Hysteresis of ID vs. VGS for a train of ten pulses, each with a period of 100 µs, followed by an off-state time of 10 µs and then a single 100 µs probe pulse (a) of the tenth pulse, and (b) of the probe pulse after 10 µs off-state time.
Figure 13. Hysteresis of ID vs. VGS for a train of ten pulses, each with a period of 100 µs, followed by an off-state time of 10 µs and then a single 100 µs probe pulse (a) of the tenth pulse, and (b) of the probe pulse after 10 µs off-state time.
Electronics 14 01991 g013
Figure 14. Hysteresis in response to a triangular waveform gate voltage with 100 µs pulse period and nominal ID = 350 mA 1 min after the application of the driving voltage.
Figure 14. Hysteresis in response to a triangular waveform gate voltage with 100 µs pulse period and nominal ID = 350 mA 1 min after the application of the driving voltage.
Electronics 14 01991 g014
Figure 15. (a) Hysteresis of ID vs. VGS for a single pulse with a 10 µs duration before stress, (b) hysteresis of ID vs. VGS for a single pulse with a 10 µs duration of the same device after 30 min of off-state stress, (c) RON of the same device before (pristine) and after 30 min of off-state stress at 55 V, using a 10 µs triangular pulse and ID = 350 mA.
Figure 15. (a) Hysteresis of ID vs. VGS for a single pulse with a 10 µs duration before stress, (b) hysteresis of ID vs. VGS for a single pulse with a 10 µs duration of the same device after 30 min of off-state stress, (c) RON of the same device before (pristine) and after 30 min of off-state stress at 55 V, using a 10 µs triangular pulse and ID = 350 mA.
Electronics 14 01991 g015
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Cusumano, P.; Vella, F.; Sirchia, A. Using Triangular Gate Voltage Pulses to Evaluate Hysteresis and Charge Trapping Effects in GaN on Si HEMTs. Electronics 2025, 14, 1991. https://doi.org/10.3390/electronics14101991

AMA Style

Cusumano P, Vella F, Sirchia A. Using Triangular Gate Voltage Pulses to Evaluate Hysteresis and Charge Trapping Effects in GaN on Si HEMTs. Electronics. 2025; 14(10):1991. https://doi.org/10.3390/electronics14101991

Chicago/Turabian Style

Cusumano, Pasquale, Flavio Vella, and Alessandro Sirchia. 2025. "Using Triangular Gate Voltage Pulses to Evaluate Hysteresis and Charge Trapping Effects in GaN on Si HEMTs" Electronics 14, no. 10: 1991. https://doi.org/10.3390/electronics14101991

APA Style

Cusumano, P., Vella, F., & Sirchia, A. (2025). Using Triangular Gate Voltage Pulses to Evaluate Hysteresis and Charge Trapping Effects in GaN on Si HEMTs. Electronics, 14(10), 1991. https://doi.org/10.3390/electronics14101991

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop