Hybrid Harmonic Suppression Method at DC Link of Series-Connected 18-Pulse Rectifier
Abstract
:Featured Application
Abstract
1. Introduction
2. The Proposed Rectifier with Harmonic Injection Circuit
2.1. Phase-Shifting Transformer Design
2.2. Operating Modes Analyse
3. Injection Transformer Turned Ratio Calculation
4. Capacity of the Proposed Harmonic Reduction Circuit
5. Simulation and Experiment Validation
- The turns ratio of the main transformer meets that N:N11:N12:N21:N31:N32 = :0.742:0.395:1:0.742:0.395.
- The injection transformer turns ratio meets that N7:N8 = 0.0118.
- The RMS of the power supply is 220 V, and the frequency is 50 Hz.
6. Conclusions
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Data Availability Statement
Conflicts of Interest
References
- Meng, F.G.; Yang, S.Y.; Yang, W. Summary of Multi-pulse Rectifier. Electron. Power Autom. Equip. 2012, 32, 9–22. [Google Scholar]
- Du, Q.; Gao, L.; Li, Q.; Liu, W.; Yin, X.; Meng, F. Harmonic Reduction Methods at DC Link of Series-Connected Multi-Pulse Rectifiers: A Review. IEEE Trans. Power Electron. 2022, 37, 3143–3160. [Google Scholar] [CrossRef]
- Zhang, P.; Chen, Q.; Mao, L. A type 18-pulse isolation transformer. J. Nanjing Univ. Aeronaut. Astronaut. 2014, 46, 129–136. [Google Scholar]
- Young, C.M.; Wu, S.F.; Yeh, W.S.; Yeh, C.W. A DC-Side Current Injection Method for Improving AC Line Condition Applied in the 18-Pulse Converter System. IEEE Trans. Power Electron. 2014, 29, 99–109. [Google Scholar] [CrossRef]
- Nguyen, T.H.; Lee, D.C.; Kim, C.K. A Series-Connected Topology of a Diode Rectifier and a Voltage-Source Converter for an HVDC Transmission System. IEEE Trans. Power Electron. 2014, 29, 1579–1584. [Google Scholar] [CrossRef]
- Yuan, D.S.; Wang, S.H.; Zhang, H.J.; Tao, X.; Zhu, J.G.; Guo, Y.G. The Harmonic Suppression Characteristic Analysis of a Phase-Shifting Reactor in Rectifier System. IEEE Trans. Magn. 2015, 51, 1–4. [Google Scholar] [CrossRef]
- Singh, B.; Bhuvaneswari, G.; Garg, V. An Improved Power-Quality 30-Pulse AC–DC for Varying Loads. IEEE Trans. Power Deliv. 2007, 22, 1179–1187. [Google Scholar] [CrossRef]
- Guimaraes, C.; Olivier, G.; April, G.E. High Current AC/DC Power Converters using T-connected Transformers. In Proceedings of the 1995 Canadian Conference on Electrical and Computer Engineering, Montreal, QC, Canada, 5–8 September 1995. [Google Scholar]
- Daniel, M.Z.; Paul, I.N.; Tao, J.; Joseph, S.M. An Improved Topology for Multipulse AC/DC Converters Within HVDC and VFD Systems: Operation in Degraded Modes. IEEE Trans. Ind. Electron. 2018, 65, 3646–3656. [Google Scholar]
- Lyubov, R.; Anton, G.; Anton, M. Installed Power of Transformers for Equivalent Multiphase Rectification Circuits. In Proceedings of the 2019 International Conference on Electrotechnical Complexes and Systems, Ufa, Russia, 21–25 October 2019. [Google Scholar]
- Wang, T.J.; Fang, F.; Jiang, X.Y.; Wang, K.Y.; Yang, L. Performance and Design Analysis on Round-Shaped Transformers Applied in Rectifier Systems. IEEE Trans. Ind. Electron. 2017, 64, 948–955. [Google Scholar] [CrossRef]
- Meng, F.G.; Qing, X.D.; Wang, L.; Gao, L.; Man, Z.C. A Series-Connected 24-Pulse Rectifier Using Passive Voltage Harmonic Injection Method at DC-Link. IEEE Trans. Power Electron. 2019, 34, 8503–8512. [Google Scholar] [CrossRef]
- Liu, Y.H.; Arrillaga, J.; Watson, N.R. A new high-pulse voltage-sourced converter for HVDC transmission. IEEE Trans. Power Deliv. 2003, 18, 1388–1393. [Google Scholar] [CrossRef]
- Bai, S.; Lukic, S.M. New Method to Achieve AC Harmonic Elimination and Energy Storage Integration for 12-Pulse Diode Rectifiers. IEEE Trans. Ind. Electron. 2013, 60, 2547–2554. [Google Scholar] [CrossRef]
- Chivite-Zabalza, F.J.; Forsyth, A.J.; Araujo-Vargas, I. 36-pulse hybrid ripple injection for high-performance aerospace rectifiers. IEEE Trans. Ind. Appl. 2009, 45, 992–999. [Google Scholar] [CrossRef]
- Li, Q.H.; Meng, F.G.; Gao, L.; Zhang, H.Q.; Du, Q.X. A 30-Pulse Rectifier Using Passive Voltage Harmonic Injection Method at DC Link. IEEE Trans. Ind. Electron. 2020, 67, 9273–9291. [Google Scholar] [CrossRef]
Voltage | Level | Voltage | Level |
---|---|---|---|
u1 | u7 | ||
u2 | u8 | ||
u3 | u9 | ||
u4 | u10 | ||
u5 | u11 | ||
u6 | u12 |
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations. |
© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
Li, Q.; Yin, X.; Meng, F.; He, X.; Wang, G.; Guo, C. Hybrid Harmonic Suppression Method at DC Link of Series-Connected 18-Pulse Rectifier. Appl. Sci. 2022, 12, 5544. https://doi.org/10.3390/app12115544
Li Q, Yin X, Meng F, He X, Wang G, Guo C. Hybrid Harmonic Suppression Method at DC Link of Series-Connected 18-Pulse Rectifier. Applied Sciences. 2022; 12(11):5544. https://doi.org/10.3390/app12115544
Chicago/Turabian StyleLi, Quanhui, Xinyu Yin, Fangang Meng, Xiao He, Gaojie Wang, and Changxing Guo. 2022. "Hybrid Harmonic Suppression Method at DC Link of Series-Connected 18-Pulse Rectifier" Applied Sciences 12, no. 11: 5544. https://doi.org/10.3390/app12115544
APA StyleLi, Q., Yin, X., Meng, F., He, X., Wang, G., & Guo, C. (2022). Hybrid Harmonic Suppression Method at DC Link of Series-Connected 18-Pulse Rectifier. Applied Sciences, 12(11), 5544. https://doi.org/10.3390/app12115544