Next Article in Journal
Subtypes of the Completely Reversed Flow Waveform in Vertebral Artery Can Help to Differentiate Subclavian Artery Occlusion from Severe Stenosis
Next Article in Special Issue
Factors Associated with Impaired Resistive Reserve Ratio and Microvascular Resistance Reserve
Previous Article in Journal
Increased Epicardial Adipose Tissue (EAT), Left Coronary Artery Plaque Morphology, and Valvular Atherosclerosis as Risks Factors for Sudden Cardiac Death from a Forensic Perspective
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Comparison of Safety of RADial comPRESSion Devices: A Multi-Center Trial of Patent Hemostasis following Percutaneous Coronary Intervention from Conventional Radial Access (RAD-PRESS Trial)

1
Heart and Vascular Center, Semmelweis University, 1122 Budapest, Hungary
2
2nd Department of Internal Medicine and Cardiology Center, University of Szeged, 6720 Szeged, Hungary
3
Department of Cardiology and Cardiac Surgery, University of Debrecen, 4032 Debrecen, Hungary
*
Author to whom correspondence should be addressed.
Diagnostics 2023, 13(1), 143; https://doi.org/10.3390/diagnostics13010143
Submission received: 3 October 2022 / Revised: 20 December 2022 / Accepted: 29 December 2022 / Published: 1 January 2023
(This article belongs to the Special Issue New Techniques in Interventional Cardiology)

Abstract

:
Although radial access is the current gold standard for the implementation of percutaneous coronary interventions (PCI), post-procedural radial compression devices are seldom compared with each other in terms of safety or efficacy. Our group aimed to compare a cost effective and potentially green method to dedicated radial compression devices, with respect to access site complications combined in a device oriented complex endpoint (DOCE), freedom from which served as our primary endpoint. Patients undergoing PCI were randomized to receive either the cost effective or a dedicated device, either of which were removed using patent hemostasis. Twenty-four hours after the procedure, radial artery ultrasonography was performed to evaluate the access site. The primary endpoint was assessed using a non-inferiority framework with a non-inferiority margin of five percentage points, which was considered as the least clinically meaningful difference. The cost-effective technique and the dedicated devices were associated with a comparably low rate of complications (freedom from DOCE: 83.3% vs. 70.8%, absolute risk difference: 12.5%, one-sided 95% confidence interval (CI): 1.11%). Composition of the DOCE (i.e., no complication, hematoma, pseudoaneurysm, and radial artery occlusion) and compression time were also assessed in superiority tests as secondary endpoints. Both the cost-effective technique and the dedicated devices were associated with comparably low rates of complications: p = 0.1289. All radial compression devices performed similarly when considering the time to complete removal of the respective device (120.0 (inter-quartile range: 100.0–142.5) for the vial vs. 120.0 (inter-quartile range: 110.0–180) for the dedicated device arm, with a median difference of [95% CI]: 7.0 [−23.11 to 2.00] min, p = 0.2816). In conclusion, our cost-effective method was found to be non-inferior to the dedicated devices with respect to safety, therefore it is a safe alternative to dedicated radial compression devices, as well as seeming to be similarly effective.

1. Introduction

Radial artery access is recommended as the standard approach for invasive coronary angiography and percutaneous coronary interventions (PCI) in the European Society of Cardiology Guidelines due to its effectiveness and safety compared with femoral access [1]. Complications such as occlusion or (pseudo)aneurysm of the radial artery and hematoma formation at the access site, however, are prevalent complications following transradial procedures. Radial artery occlusion (RAO) was initially found to be occurring in up to 33% of transradial procedures [2], which later decreased substantially according to more recent results [3]. The development of patent hemostasis [4,5] might have had an impact on these favorable changes. RAO remains, however, the most frequent vascular complication following radial access. As many of the suspected predictors of RAO are difficult to be addressed [6,7,8,9], modifiable procedural and post-procedural risk factors such as inadequate anticoagulation and occlusive or prolonged hemostasis should be reduced to further mitigate its incidence [10,11].
A multitude of compression devices have been developed, the two most frequently applied solutions of which are mechanical and pneumatic. The performance of these dedicated devices are seldom compared with each other in terms of safety or efficacy, therefore there is limited evidence to support the use of any single hemostatic method to prevent RAO and other access site complications after percutaneous coronary procedures [12,13].
Our institutions historically utilized a cost effective and potentially green method to compress the radial artery following invasive angiography and PCI: we reuse the glass vial of the intravenous medication heparin, cover it in a sterile gauze and place it above the access site, compress it with an elastic bandage, and then secure it with two clamps (Figure 1). We designed the RAD-PRESS trial to assess the safety of this vial technique compared with two major dedicated industrial solutions.

2. Materials and Methods

The RAD-PRESS trial was designed as a multicenter, prospective, randomized non-inferiority safety trial aiming to assess safety of a cost-effective radial compression device compared with dedicated and widely used competitors in patients undergoing PCI from radial access. Inclusion and exclusion criteria for the study are listed in Table 1. The primary endpoint for the study was freedom from a device oriented complex endpoint (DOCE) comprising radial artery occlusion, formation of a radial artery aneurysm, and bleeding from or hematoma of the access site, all within 24 h after implementing the below detailed patent hemostasis protocol following the index procedure. Secondary endpoints were components of the primary endpoint. Compression time needed to achieve primary hemostasis was also recorded for every subject. All procedures related to the trial were performed after informed consent was obtained from participants. The RAD-PRESS trial was catalogued and authorized by the Hungarian National Institute of Pharmacy and Nutrition under number: OGYÉI/24194/2018.
All elective patients between age 18 and 85, referred to the cardiac catheterization laboratories involved in the trial, were invited to participate in the study unless fulfilling an exclusion criterion (Figure 2). After consent was obtained, radial artery diameter was assessed using vascular ultrasound. Patients with radial artery diameter smaller than 1.8 mm were excluded from the trial (early screen failure) [7]. Diagnostic coronary angiography was then completed using a 6F hydrophilic introducer sheath and 5F diagnostic catheters as required by the anatomical situation, and patients not requiring PCI were also excluded (late screen failure). Late screen failure occurred if an alternative access site or a guiding catheter larger than 6F was required for any reason during the intervention as well (Figure 2). Baseline demographic, clinical and procedural data of the patients were recorded.
Simple randomization to a screw-knob/pneumatic balloon (together: Dedicated) Device or the Vial technique was done after completion of the intervention in a 1:1 ratio between the groups as well as within Dedicated Devices. Compression devices were applied as follows or as detailed in Figure 1 for the Vial group. Compression rate of the screw-knob device used in this trial can be set in 9 steps. By default, we used step 6 for all patients. If bleeding was visible from the puncture site at this setting, compression was increased by 2 steps. For the pneumatic balloon device, the default air volume used for compression was 12 mL. Similar to the screw-knob device, on occasion of visible bleeding from the access site, a further 2 mL of air was added. The increase in compression described above sufficed for the patients in whom the default settings were insufficient with these devices.
All compressive devices were attempted to be removed utilizing a patent hemostasis protocol based on the one used in PROPHET and PROPHET II trials [4,14] as follows (Figure 2). Pulse oximetry was used to guide the release of compression in every 10 min by releasing one step, deflating 2 mL of air, or unwinding two rotations of the wrapping for the screw-knob, pneumatic balloon, and the Vial technique, respectively. The ipsilateral ulnar artery was compressed manually during the first attempt at decompression until plethysmographic signal returned on the pulse oximeter. On occasion of bleeding from the access site as a result of this maneuver, compression was increased again by increasing one step, inflation of 2 mL of air, or rewinding two rotations of the wrapping for the screw-knob, pneumatic balloon, and the Vial technique, respectively. Decompression was reattempted 10 min later. For further decompressions, the above steps were repeated. Time required to completely remove the compression device was set at 120 min, and was recorded for every subject. Radial artery ultrasound was repeated by an investigator blinded to the study groups 24 h after the index procedure to evaluate the access site with respect to the DOCE. Hematoma formation was assessed as well at 24 h based on the EASY hematoma scale [15].
From a statistical aspect, the study was primarily designed using a non-inferiority framework. The null hypothesis was that the rate of the primary endpoint (DOCE) for the heparin Vial group is 5.0 percentage points lower than that in the Dedicated Device group, i.e., the non-inferiority margin was set at 5–percentage points which was considered as the least clinically meaningful difference. The treatment arms were compared using the 1-sided 95% confidence interval (CI) approach.
Though our study was conceived as a non-inferiority analysis, the data were also evaluated for possible superiority. Therefore, the treatment arms were compared using the 2-sided 95% CI approach and a 2 tailed p value less than 0.05 was considered statistically significant. The primary endpoint was analyzed using Fisher’s exact test. As to the secondary endpoints, composition of the DOCE (i.e., no complication, hematoma, pseudoaneurysm, and radial artery occlusion) was assessed by the exact Cochran–Armitage test in order to detect trends in data from 2 × 4 contingency tables, whereas compression times were compared using the exact Mann–Whitney test. All statistical analyses and graphical interpretations of the results were carried out with R version 4.2.1 (R Foundation for Statistical Computing, Vienna, Austria) using the coin 1.4 2, dplyr 1.0.9, epiR 2.0.50, fBasics 3042.89.2, ggplot2 3.3.6, and Hmisc 4.7-0 additional packages. All analyses were done on an intention-to-treat basis.

3. Results

3.1. Clinical Data

The baseline characteristics of the patients are presented in Table 1. There were no significant differences among the groups.

3.2. Efficacy and Safety Data

The primary endpoint was met in the Dedicated Device and the Vial groups similarly (Table 2). Distribution of the components of the DOCE were also comparable between the groups with hematoma formation of EASY Grade 1 and 2 being the most prevalent complication (Table 2).
The median difference in compression time was -7.0 min (median difference [95% CI]: 7.0 [-23.11 to 2.00] min., p = 0.2816). Therefore, the Vial technique was found to be non-inferior to Dedicated Devices with respect to the DOCE, while superiority was not reached (Figure 3).

4. Discussion

In the present study we provide evidence that a cost-effective, and through the recycling glass vials, a potentially green alternative is non-inferior to dedicated radial compression devices in terms of the avoidance of complications of the access site when performing patent hemostasis in patients undergoing percutaneous coronary interventions from a conventional radial access.
A multitude of radial compression devices have been developed by companies around the globe. Safety and efficacy of some of these have been investigated in comparative studies [16,17,18,19], but all of the investigated devices were dedicated to the radial access site. This is the first instance in which a cost-effective heparin vial method, which also satisfies the increasingly more important aspect of environmental awareness, is compared with a dedicated radial compression device.
The primary endpoint was met in a similar number of patients in both the Vial and Dedicated Device groups (Table 2). Furthermore, secondary endpoints, i.e., hematoma formation, pseudoaneurysm, or RAO rates (Table 2) also did not differ among the groups. Our data are in line with previously found complication rates of 5–18% for hematoma [16,17,18,19]. RAO, on the other hand, at a rate of 1% was considerably less prevalent in our cohort than in previous comparative studies, which reported RAO to occur in 2–14% [16,17,18,19]. This result might be attributable to the patent hemostasis protocol utilized by our group during the investigation. Although distal radial access has emerged in recent years as a potentially effective method to reduce access site complication rates including RAO, according to the latest data coming from a large, randomized trial, it does not provide benefit in this regard compared with conventional radial access when hemostasis is adequately managed [20]. This result is in line with our data in the RAD-PRESS trial, in which we utilized a rigorous patent hemostasis protocol and produced an RAO rate of 1.4%. Overall, our data suggests that both approaches utilized in the study achieved safe hemostasis following PCI, the Vial technique being non-inferior to Dedicated Device technique in this regard (Figure 3).
To our knowledge, there are no published data about the treatment effect of heparin vials as compression devices. However, based on our single-center, unpublished registry data, we assumed a primary endpoint frequency of 70.0% and 83.0% in the Dedicated Device and Vial groups, respectively. Thus, the enrollment of 134 patients (67 in each arm) would have provided the study with a statistical power of 80.0% to detect a 5.0% decrease in the rate of the primary endpoint at a 1-sided α level of 0.05. With the observed event rates and final sample size of 144 patients (72 in each group), the study has an a posteriori statistical power of 80.1% to detect the null hypothesis at a 1-sided α level of 0.05.
In conclusion, our data suggest that the cost-effective and green vial technique is similarly safe and potentially similarly effective as dedicated devices in compressing the radial artery following percutaneous coronary interventions from conventional radial access. The environmentally friendly recycling of heparin vials therefore is a viable option for the compression of the radial artery.

5. Limitations

There are a few limitations of the trial discussed herein that need to be addressed. First, a follow-up of only 24 h is not enough to detect all RAOs, as some of these occur later. A longer follow-up of at least 30 days would potentially result in a higher rate of RAO. A further limiting factor is that the Vial technique cannot be undoubtedly standardized, therefore user variability might have had a role in the results of the Vial group. Moreover, as superficial and not just deep hematomas were counted, these might have been over diagnosed in this trial, hence the relatively large number of hematomas in comparison with other, large, randomized trials. The observed rate of other complications combined in the DOCE at 24 h was very low, which mandates caution when interpreting our results despite the study being adequately powered statistically. Larger trials with more power are warranted to fully uncover the rate of complications when using the Vial technique.

Author Contributions

Conceptualization, I.F.E.; methodology, I.F.E.; investigation, B.T.N., I.H., F.N., Z.R., T.S., P.K., G.A.F., F.E.S., D.B., B.M. and I.F.E.; statistical analysis, I.H.; writing—original draft preparation, B.T.N. and I.H.; writing—review and editing, D.B., B.M. and I.F.E.; visualization, B.T.N. and I.H.; supervision, B.M. and I.F.E. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

The study was conducted in accordance with the Declaration of Helsinki and approved by the Hungarian National Institute of Pharmacy and Nutrition under number OGYÉI/24194/2018.

Informed Consent Statement

Informed consent was obtained from all subjects involved in the study.

Data Availability Statement

The data are not publicly available due to constraints from the authority issuing the study authorization.

Acknowledgments

The Authors would like to thank the staff of the catheterization laboratories of all institutions involved, for their dedicated effort in the success of the study published herein.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Neumann, F.J.; Sousa-Uva, M.; Ahlsson, A.; Alfonso, F.; Banning, A.P.; Benedetto, U.; Byrne, R.A.; Collet, J.P.; Falk, V.; Head, S.J.; et al. 2018 ESC/EACTS Guidelines on myocardial revascularization. Eur. Heart J. 2019, 40, 87–165. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  2. Rashid, M.; Kwok, C.S.; Pancholy, S.; Chugh, S.; Kedev, S.A.; Bernat, I.; Ratib, K.; Large, A.; Fraser, D.; Nolan, J.; et al. Radial Artery Occlusion After Transradial Interventions: A Systematic Review and Meta-Analysis. J. Am. Heart Assoc. 2016, 5, e002686. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  3. Bernat, I.; Aminian, A.; Pancholy, S.; Mamas, M.; Gaudino, M.; Nolan, J.; Gilchrist, I.C.; Saito, S.; Hahalis, G.N.; Ziakas, A.; et al. Best Practices for the Prevention of Radial Artery Occlusion After Transradial Diagnostic Angiography and Intervention: An International Consensus Paper. JACC Cardiovasc. Interv. 2019, 12, 2235–2246. [Google Scholar] [CrossRef]
  4. Pancholy, S.; Coppola, J.; Patel, T.; Roke-Thomas, M. Prevention of radial artery occlusion-patent hemostasis evaluation trial (PROPHET study): A randomized comparison of traditional versus patency documented hemostasis after transradial catheterization. Catheter. Cardiovasc. Interv. 2008, 72, 335–340. [Google Scholar] [CrossRef]
  5. Eid-Lidt, G.; Reyes-Carrera, J.; Farjat-Pasos, J.I.; Saenz, A.L.; Bravo, C.A.; Rangel, S.N.; Salido, D.Z.; Vega Servin, N.S.; Soto-López, M.E.; Gaspar, J. Prevention of Radial Artery Occlusion of 3 Hemostatic Methods in Transradial Intervention for Coronary Angiography. JACC Cardiovasc. Interv. 2022, 15, 1022–1029. [Google Scholar] [CrossRef]
  6. Dahm, J.B.; Vogelgesang, D.; Hummel, A.; Staudt, A.; Volzke, H.; Felix, S.B. A randomized trial of 5 vs. 6 French transradial percutaneous coronary interventions. Catheter. Cardiovasc. Interv. 2002, 57, 172–176. [Google Scholar] [CrossRef] [PubMed]
  7. Saito, S.; Ikei, H.; Hosokawa, G.; Tanaka, S. Influence of the ratio between radial artery inner diameter and sheath outer diameter on radial artery flow after transradial coronary intervention. Catheter. Cardiovasc. Interv. 1999, 46, 173–178. [Google Scholar] [CrossRef]
  8. Wu, S.S.; Galani, R.J.; Bahro, A.; Moore, J.A.; Burket, M.W.; Cooper, C.J. 8 french transradial coronary interventions: Clinical outcome and late effects on the radial artery and hand function. J. Invasive Cardiol. 2000, 12, 605–609. [Google Scholar] [PubMed]
  9. Hahalis, G.; Aznaouridis, K.; Tsigkas, G.; Davlouros, P.; Xanthopoulou, I.; Koutsogiannis, N.; Koniari, I.; Leopoulou, M.; Costerousse, O.; Tousoulis, D.; et al. Radial Artery and Ulnar Artery Occlusions Following Coronary Procedures and the Impact of Anticoagulation: ARTEMIS (Radial and Ulnar ARTEry Occlusion Meta-AnalysIS) Systematic Review and Meta-Analysis. J. Am. Heart Assoc. 2017, 6, e005430. [Google Scholar] [CrossRef] [PubMed]
  10. Aminian, A.; Saito, S.; Takahashi, A.; Bernat, I.; Jobe, R.L.; Kajiya, T.; Gilchrist, I.C.; Louvard, Y.; Kiemeneij, F.; Van Royen, N.; et al. Comparison of a new slender 6 Fr sheath with a standard 5 Fr sheath for transradial coronary angiography and intervention: RAP and BEAT (Radial Artery Patency and Bleeding, Efficacy, Adverse evenT), a randomised multicentre trial. EuroIntervention 2017, 13, e549–e556. [Google Scholar] [CrossRef] [PubMed]
  11. Kotowycz, M.A.; Johnston, K.W.; Ivanov, J.; Asif, N.; Almoghairi, A.M.; Choudhury, A.; Nagy, C.D.; Sibbald, M.; Chan, W.; Seidelin, P.H.; et al. Predictors of radial artery size in patients undergoing cardiac catheterization: Insights from the Good Radial Artery Size Prediction (GRASP) study. Can. J. Cardiol. 2014, 30, 211–216. [Google Scholar] [CrossRef] [PubMed]
  12. Fernandez, R.S.; Lee, A. Effects of methods used to achieve hemostasis on radial artery occlusion following percutaneous coronary procedures: A systematic review. JBI Database Syst. Rev. Implement. Rep. 2017, 15, 738–764. [Google Scholar] [CrossRef] [PubMed]
  13. Sanghvi, K.A.; Montgomery, M.; Varghese, V. Effect of hemostatic device on radial artery occlusion: A randomized comparison of compression devices in the radial hemostasis study. Cardiovasc. Revasc. Med. 2018, 19, 934–938. [Google Scholar] [CrossRef] [PubMed]
  14. Pancholy, S.B.; Bernat, I.; Bertrand, O.F.; Patel, T.M. Prevention of Radial Artery Occlusion After Transradial Catheterization: The PROPHET-II Randomized Trial. JACC Cardiovasc. Interv. 2016, 9, 1992–1999. [Google Scholar] [CrossRef] [PubMed]
  15. Bertrand, O.F. Acute forearm muscle swelling post transradial catheterization and compartment syndrome: Prevention is better than treatment! Catheter. Cardiovasc. Interv. 2010, 75, 366–368. [Google Scholar] [CrossRef] [PubMed]
  16. Dai, N.; Xu, D.C.; Hou, L.; Peng, W.H.; Wei, Y.D.; Xu, Y.W.A. comparison of 2 devices for radial artery hemostasis after transradial coronary intervention. J. Cardiovasc. Nurs. 2015, 30, 192–196. [Google Scholar] [CrossRef] [PubMed]
  17. Pancholy, S.B. Impact of two different hemostatic devices on radial artery outcomes after transradial catheterization. J. Invasive Cardiol. 2009, 21, 101–104. [Google Scholar] [PubMed]
  18. Wang, Y.; Tang, J.; Ni, J.; Chen, X.; Zhang, R.A. comparative study of TR Band and a new hemostatic compression device after transradial coronary catheterization. J. Interv. Med. 2018, 1, 221–228. [Google Scholar] [PubMed]
  19. Petroglou, D.; Didagelos, M.; Chalikias, G.; Tziakas, D.; Tsigkas, G.; Hahalis, G.; Koutouzis, M.; Ntatsios, A.; Tsiafoutis, I.; Hamilos, M.; et al. Manual Versus Mechanical Compression of the Radial Artery After Transradial Coronary Angiography: The MEMORY Multicenter Randomized Trial. JACC Cardiovasc. Interv. 2018, 11, 1050–1058. [Google Scholar] [CrossRef] [PubMed]
  20. Aminian, A.; Sgueglia, G.A.; Wiemer, M.; Kefer, J.; Gasparini, G.L.; Ruzsa, Z.; van Leeuwen MA, H.; Ungureanu, C.; Leibundgut, G.; Vandeloo, B.; et al. Distal Versus Conventional Radial Access for Coronary Angiography and Intervention: The DISCO RADIAL Trial. JACC Cardiovasc. Interv. 2022, 15, 1191–1201. [Google Scholar] [CrossRef] [PubMed]
Figure 1. Placement of the vial compression. (a) After completion of the procedure, the surroundings of the access site are cleaned. (b) A sterile gauze is placed above the access site, with the sheath still in place. (c) The reused vial wrapped in sterile gauze is placed above the access site, with its longer axis parallel to the radial artery. (d) The sheath is then removed, (e) while applying sufficient pressure to prevent bleeding. (f,g) An elastic bandage is then wound six times around the vial, (h) after which it is cut above the access site. (i) After the loose end of the elastic bandage is secured, the compression is functional.
Figure 1. Placement of the vial compression. (a) After completion of the procedure, the surroundings of the access site are cleaned. (b) A sterile gauze is placed above the access site, with the sheath still in place. (c) The reused vial wrapped in sterile gauze is placed above the access site, with its longer axis parallel to the radial artery. (d) The sheath is then removed, (e) while applying sufficient pressure to prevent bleeding. (f,g) An elastic bandage is then wound six times around the vial, (h) after which it is cut above the access site. (i) After the loose end of the elastic bandage is secured, the compression is functional.
Diagnostics 13 00143 g001
Figure 2. Summary of the study protocol.
Figure 2. Summary of the study protocol.
Diagnostics 13 00143 g002
Figure 3. The Vial technique is non-inferior compared with Dedicated Device with respect to DOCE.
Figure 3. The Vial technique is non-inferior compared with Dedicated Device with respect to DOCE.
Diagnostics 13 00143 g003
Table 1. Baseline Demographic, Clinical, and Procedural Characteristics.
Table 1. Baseline Demographic, Clinical, and Procedural Characteristics.
VariableDedicated Device
(n = 72)
Vial
(n = 72)
Age
Median (IQR) (years)
66.5 (58.0–74.3)65.5 (57.8–70.3)
Female31 (43.1%)24 (33.3%)
Hypertension62 (86.1%)65 (90.3%)
Diabetes mellitus23 (31.9%)31 (43.1%)
Hyperlipoproteinemia59 (81.9%)52 (72.2%)
Peripheral arterial disease7 (9.7%)4 (5.6%)
Impaired renal function 115 (20.8%)11 (15.3%)
Acute coronary syndrome22 (30.6%)13 (18.1%)
Right radial artery60 (83.3%)63 (87.5%)
Radial artery diameter
Median (IQR) (mm)
2.5 (2.1–2.8)2.55 (2.1–3.0)
IQR—inter-quartile range; 1—GFR <60 mL/min.
Table 2. Results.
Table 2. Results.
Outcome MeasureDedicated Device
(n = 72)
Vial
(n = 72)
p Value
(Two-Sided)
Primary endpoint
Freedom from DOCE51 (70.8%)60 (83.3%)0.11
Secondary endpoints68 (94.4%)69 (95.8%)1.0
Distribution of outcomes
No complication51 (70.8%)60 (83.3%)
Hematoma20 (27.8%)11 (15.3%)0.13
Pseudoaneurysm1 (1.4%)0 (0.0%)
Radial artery occlusion0 (0.0%)1 (1.4%)
Compression time (min)120.0 (110.0–180)120.0 (100.0–142.5)0.28
DOCE—device oriented complex endpoint.
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Nemeth, B.T.; Hizoh, I.; Nowotta, F.; Ruzsa, Z.; Szuk, T.; Kulyassa, P.; Fulop, G.A.; Szablics, F.E.; Becker, D.; Merkely, B.; et al. Comparison of Safety of RADial comPRESSion Devices: A Multi-Center Trial of Patent Hemostasis following Percutaneous Coronary Intervention from Conventional Radial Access (RAD-PRESS Trial). Diagnostics 2023, 13, 143. https://doi.org/10.3390/diagnostics13010143

AMA Style

Nemeth BT, Hizoh I, Nowotta F, Ruzsa Z, Szuk T, Kulyassa P, Fulop GA, Szablics FE, Becker D, Merkely B, et al. Comparison of Safety of RADial comPRESSion Devices: A Multi-Center Trial of Patent Hemostasis following Percutaneous Coronary Intervention from Conventional Radial Access (RAD-PRESS Trial). Diagnostics. 2023; 13(1):143. https://doi.org/10.3390/diagnostics13010143

Chicago/Turabian Style

Nemeth, Balazs T., Istvan Hizoh, Fanni Nowotta, Zoltan Ruzsa, Tibor Szuk, Peter Kulyassa, Gabor A. Fulop, Fanni E. Szablics, David Becker, Bela Merkely, and et al. 2023. "Comparison of Safety of RADial comPRESSion Devices: A Multi-Center Trial of Patent Hemostasis following Percutaneous Coronary Intervention from Conventional Radial Access (RAD-PRESS Trial)" Diagnostics 13, no. 1: 143. https://doi.org/10.3390/diagnostics13010143

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop