Next Article in Journal
Association of Tinnitus with Depression in a Normal Hearing Population
Previous Article in Journal
Epidemiology of Chronic Kidney Disease in Children: A Report from Lithuania
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

The Influence of Antiarrhythmic Device Intervention on Biopsychosocial Functioning and Anxiety in Patients with an Implanted Cardioverter Defibrillator

by
Olimpia Karczewska
1,2,* and
Agnieszka Młynarska
2
1
Department of Anaesthesia and Intensive Nursing Care, Faculty of Health Sciences in Katowice, Medical University of Silesia, 40-635 Katowice, Poland
2
Department of Gerontology and Geriatric Nursing, Faculty of Health Sciences in Katowice, Medical University of Silesia, 40-635 Katowice, Poland
*
Author to whom correspondence should be addressed.
Medicina 2021, 57(2), 113; https://doi.org/10.3390/medicina57020113
Submission received: 10 December 2020 / Revised: 6 January 2021 / Accepted: 22 January 2021 / Published: 27 January 2021

Abstract

Background and objectives: The aim of the study was to assess the impact of cardioverter-defibrillator interventions on the psychosocial functioning of a patient and the occurrence of concerns related to ICD. Materials and Methods: The conducted study was a prospective and observational study that included 158 patients. The study was conducted in two stages: I before ICD implantation and II a follow-up visit six months after the ICD implantation. Standardized questionnaires were used in both stages. Results: In the first six months, a cardioverter-defibrillator discharge occurred in 28 participants, which constituted 17.72% of the study group. The number of ICD discharges positively correlated to insomnia, symptoms of anxiety, symptoms of depression, more discharges, more severe insomnia, anxiety and depression. There was also a negative correlation between the number of discharges and the degree of disease acceptance and in the quality of life domains: somatic, mental, social and environmental. The more discharges, the worse the disease acceptance and assessment of the quality of life. Conclusions: Individuals who experienced discharges assessed their quality of life as worse in all aspects (perception of the quality of life, own health, physical, mental, social and environmental domains), experienced anxiety and depressive disorders more often, were characterized by a worse functioning in a chronic disease, experienced insomnia more often and reported more concerns related to ICD implantation.
Keywords: implantable cardioverter defibrillator; discharge; concerns; quality of life; anxiety implantable cardioverter defibrillator; discharge; concerns; quality of life; anxiety

Share and Cite

MDPI and ACS Style

Karczewska, O.; Młynarska, A. The Influence of Antiarrhythmic Device Intervention on Biopsychosocial Functioning and Anxiety in Patients with an Implanted Cardioverter Defibrillator. Medicina 2021, 57, 113. https://doi.org/10.3390/medicina57020113

AMA Style

Karczewska O, Młynarska A. The Influence of Antiarrhythmic Device Intervention on Biopsychosocial Functioning and Anxiety in Patients with an Implanted Cardioverter Defibrillator. Medicina. 2021; 57(2):113. https://doi.org/10.3390/medicina57020113

Chicago/Turabian Style

Karczewska, Olimpia, and Agnieszka Młynarska. 2021. "The Influence of Antiarrhythmic Device Intervention on Biopsychosocial Functioning and Anxiety in Patients with an Implanted Cardioverter Defibrillator" Medicina 57, no. 2: 113. https://doi.org/10.3390/medicina57020113

APA Style

Karczewska, O., & Młynarska, A. (2021). The Influence of Antiarrhythmic Device Intervention on Biopsychosocial Functioning and Anxiety in Patients with an Implanted Cardioverter Defibrillator. Medicina, 57(2), 113. https://doi.org/10.3390/medicina57020113

Article Metrics

Back to TopTop