Reviewer 1:
Reviewer 2: Anonymous
Sensors 2023, 23(9), 4340; https://doi.org/10.3390/s23094340
Submission received: 20 February 2023 / Revised: 19 April 2023 / Accepted: 25 April 2023 / Published: 27 April 2023
(This article belongs to the Special Issue Wearable Biomedical Devices and Sensors)

Round 1

Reviewer 1 Report

This paper applied IMU data to match EMG signals. The idea is novel, but the applicability of the algorithm was not clearly introduced. It is suggested to modify from the following aspects:

1. It was suggested to add the position diagram of the IMU sensors.

2. As Section 2.1, Why not use the same sampling rate to obtain two kinds of data for interpolation?

3. What signals were filtered in Section 2.2?

4. There are no specific parameters about the database, including sample size or the number of experimentalists. 

5. In the third part, the single IMU signal has been able to better identify gait, so why the EMG signal was superimposed? If there was improvement, specific indicators should be added for comparison.

6. Line 233 of the third part, the data set used in the experiment did not contain EMG signals, so what’s significance of the experiment?

7. In the conclusion part, no specific parameter index was given to verify the advantages of the proposed algorithm and no comparison was made with other algorithms.

The engineering significance of this paper was not clear either, so it was suggested to clarify the engineering significance.

Author Response

Dear Reviewer,

Annexed is the letter answering your queries.

Kind regards,
Rafael Aguiar

Author Response File: Author Response.pdf

Reviewer 2 Report

The manuscript provides protocol of stride detection pipeline (sMaSDP) for surface EMG segmentation. This article is important from a theoretical point of view for professionals who work with the patients with gait disorders. Nevertheless, it is necessary to make a few comments, the work on which, in my opinion, will help improve the quality of your manuscript.

1.    Could you comment equations 1 and 2?

2.    You should give a link on Figure 6 in the text of your manuscript.

3.    It remains unclear the aim of EEG recording (p.4 line 122).

Author Response

Dear Reviewer,

Annexed I am submitting a letter answering your queries.

Kind regards,
Rafael Aguiar

Author Response File: Author Response.pdf

Round 2

Reviewer 1 Report

  • The content of the article should be revised as appropriate.