Next Article in Journal
Automatic Stem Mapping by Merging Several Terrestrial Laser Scans at the Feature and Decision Levels
Previous Article in Journal
Temperature Grid Sensor for the Measurement of Spatial Temperature Distributions at Object Surfaces
 
 
Article

Critical Evaluation of Acetylthiocholine Iodide and Acetylthiocholine Chloride as Substrates for Amperometric Biosensors Based on Acetylcholinesterase

National Institute of Research and Development for Biological Sciences, Bioanalysis Center, 296 Splaiul Independentei, Bucharest 060031, Romania
*
Author to whom correspondence should be addressed.
Sensors 2013, 13(2), 1603-1613; https://doi.org/10.3390/s130201603
Received: 30 November 2012 / Revised: 15 January 2013 / Accepted: 22 January 2013 / Published: 25 January 2013
(This article belongs to the Section Biosensors)
Numerous amperometric biosensors have been developed for the fast analysis of neurotoxic insecticides based on inhibition of cholinesterase (AChE). The analytical signal is quantified by the oxidation of the thiocholine that is produced enzymatically by the hydrolysis of the acetylthiocholine pseudosubstrate. The pseudosubstrate is a cation and it is associated with chloride or iodide as corresponding anion to form a salt. The iodide salt is cheaper, but it is electrochemically active and consequently more difficult to use in electrochemical analytical devices. We investigate the possibility of using acetylthiocholine iodide as pseudosubstrate for amperometric detection. Our investigation demonstrates that operational conditions for any amperometric biosensor that use acetylthiocholine iodide must be thoroughly optimized to avoid false analytical signals or a reduced sensitivity. The working overpotential determined for different screen-printed electrodes was: carbon-nanotubes (360 mV), platinum (560 mV), gold (370 mV, based on a catalytic effect of iodide) or cobalt phthalocyanine (110 mV, but with a significant reduced sensitivity in the presence of iodide anions). View Full-Text
Keywords: acetylthiocholine iodide; acetylthiocholine chloride; amperometry; acetylcholinesterase acetylthiocholine iodide; acetylthiocholine chloride; amperometry; acetylcholinesterase
Show Figures

MDPI and ACS Style

Bucur, M.-P.; Bucur, B.; Radu, G.-L. Critical Evaluation of Acetylthiocholine Iodide and Acetylthiocholine Chloride as Substrates for Amperometric Biosensors Based on Acetylcholinesterase. Sensors 2013, 13, 1603-1613. https://doi.org/10.3390/s130201603

AMA Style

Bucur M-P, Bucur B, Radu G-L. Critical Evaluation of Acetylthiocholine Iodide and Acetylthiocholine Chloride as Substrates for Amperometric Biosensors Based on Acetylcholinesterase. Sensors. 2013; 13(2):1603-1613. https://doi.org/10.3390/s130201603

Chicago/Turabian Style

Bucur, Madalina-Petruta, Bogdan Bucur, and Gabriel-Lucian Radu. 2013. "Critical Evaluation of Acetylthiocholine Iodide and Acetylthiocholine Chloride as Substrates for Amperometric Biosensors Based on Acetylcholinesterase" Sensors 13, no. 2: 1603-1613. https://doi.org/10.3390/s130201603

Find Other Styles

Article Access Map by Country/Region

1
Only visits after 24 November 2015 are recorded.
Back to TopTop