Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (88)

Search Parameters:
Keywords = tube heater

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
10 pages, 2128 KB  
Proceeding Paper
Artificial Neural Network Model for Predicting the Characteristics of a Solar Vacuum Tube System for Domestic Hot Water Heating
by Mariyana Sestrimska, Nikolay Komitov and Margarita Terziyska
Eng. Proc. 2026, 122(1), 10; https://doi.org/10.3390/engproc2026122010 - 15 Jan 2026
Viewed by 120
Abstract
The use of different energy sources for heating and year-round domestic water heating is driven by the European Union’s increasingly strict environmental and climate requirements. For this reason, consumers are seeking alternatives and show growing interest in implementing installations that utilize solar energy. [...] Read more.
The use of different energy sources for heating and year-round domestic water heating is driven by the European Union’s increasingly strict environmental and climate requirements. For this reason, consumers are seeking alternatives and show growing interest in implementing installations that utilize solar energy. Modern households typically employ at least two different energy sources for this purpose. In practice, these are hybrid installations that, depending on the season, can operate with one, two, or more energy sources. The system examined in this paper is of this type, comprising a pellet boiler, solar vacuum tubes, and electric heaters. Managing such a system is complex, and based on the conducted studies, process optimization can be pursued. This report presents an artificial neural network (ANN) model developed to predict the behavior of a real solar installation for domestic hot water heating during the summer season. This study aims, through the obtained model, to forecast the system’s performance during transitional periods such as autumn and spring, thereby enabling more efficient control. Full article
Show Figures

Figure 1

20 pages, 15128 KB  
Article
Study of the Maximum Pressures in an Evaporator of a Direct Expansion Heat Pump Using R744 Assisted by Solar Energy
by Jéssica C. C. M. Silva, Tiago F. Paulino, Luiz Machado and Willian M. Duarte
Processes 2026, 14(1), 103; https://doi.org/10.3390/pr14010103 - 27 Dec 2025
Viewed by 380
Abstract
Replacing electric water heaters with heat pumps significantly lowers energy consumption and greenhouse gas emissions. Among the refrigerants considered, carbon dioxide (CO2 or R744) has attracted considerable attention from refrigeration specialists. However, the high operating pressures of R744 can exceed safe limits [...] Read more.
Replacing electric water heaters with heat pumps significantly lowers energy consumption and greenhouse gas emissions. Among the refrigerants considered, carbon dioxide (CO2 or R744) has attracted considerable attention from refrigeration specialists. However, the high operating pressures of R744 can exceed safe limits when heat pump components are exposed to intense solar radiation and elevated temperatures. This study develops a mathematical model for the evaporator of a Direct Expansion Solar-Assisted Heat Pump (DX-SAHP) to analyze pressure behavior when the system is inactive but subjected to solar radiation. The model also examines how these pressures affect component integrity, accounting for the mass of R744 trapped inside the evaporator. Meteorological data from Brazil’s four regions, provided by INMET, were used in the simulations. Simulations were conducted using information from five different cities and up to 10 years of climate data. Results show that for a refrigerant mass fraction of 12%, the maximum pressure reached approximately 122 bar, compared to the manufacturer’s specified limit of 132 bar for the evaporator tubes. Full article
(This article belongs to the Special Issue Process Design and Performance Analysis of Heat Pumps)
Show Figures

Figure 1

25 pages, 4000 KB  
Article
Development and Performance of a Vacuum-Based Seawater Desalination System Driven by a Solar Water Heater
by Wichean Singmai, Pichet Janpla, Suparat Jamsawang, Kittiwoot Sutthivirode and Tongchana Thongtip
Thermo 2026, 6(1), 3; https://doi.org/10.3390/thermo6010003 - 26 Dec 2025
Viewed by 351
Abstract
This work proposes the design, construction, and field test of a vacuum seawater desalination system (VSDS) driven by an evacuated tube solar collector (with a total absorption area of 1.86 m2) under tropical climatic condition (Thailand ambient at latitude 13°43′06.0″ N, [...] Read more.
This work proposes the design, construction, and field test of a vacuum seawater desalination system (VSDS) driven by an evacuated tube solar collector (with a total absorption area of 1.86 m2) under tropical climatic condition (Thailand ambient at latitude 13°43′06.0″ N, longitude 100°32′25.4″ E). The VSDS prototype was designed and constructed to be driven by hot water, which is produced by two heat source conditions: (1) an electric heater for laboratory tests and (2) an evacuated tube solar collector for field tests under real climatic conditions. A comparative experimental study to assess the ability to produce fresh water between a conventional dripping/pipe feed column and spray falling film column is proposed in the first part of the discussion. This is to demonstrate the advantage of the spray falling film distillation column. The experimental method is implemented based on the batch system, in which the cycle time (distillation time) considered is 10–20 min so that heat loss via the concentrated seawater blow down is minimized. Later, the field test with solar irradiance under real climatic conditions is demonstrated to assess the freshwater yield and the system performance. The aim is to provide evidence of the proposed vacuum desalination system in real operation. It is found experimentally that the VSDS working with spray falling film provides better performance than the dripping/pipe feed column under the specified working conditions. The spray falling film column can increase the distillated freshwater volume from 1.33 to 2.16 L under identical cycle time and working conditions. The improvement potential is up to 62.4%. The overall thermal efficiency can be increased from 33.7 to 70.8% (improvement of 110.1%). Therefore, the VSDS working with spray falling film is selected for implementing field tests based on real solar irradiance powered by an evacuated tube solar collector. The ability to produce fresh water is assessed, and the overall performance via the average distillation rate and the thermal efficiency (or Gain Output Ratio) is discussed with the real solar irradiance. It is found from the field test with solar time (8.00–16.00) that the VSDS can produce a daily freshwater yield of up to 4.5 L with a thermal efficiency of up to 19%. The freshwater production meets the requirement for international standard drinking water criteria, indicating suitability for household/community use in tropical regions. This work demonstrates the feasibility of VSDS working under real solar irradiance as an alternative technology for sustainable fresh water. Full article
Show Figures

Figure 1

18 pages, 4457 KB  
Article
Experimental Study on the Enhancement of Pool Boiling Heat Transfer Characteristics of Water-Based Nanofluids with Graphene Nanoplatelets on Nichrome Wire
by Srinivasan Venkatraman and Chandrasekaran Selvam
Thermo 2025, 5(4), 48; https://doi.org/10.3390/thermo5040048 - 3 Nov 2025
Viewed by 814
Abstract
The present study aims to experimentally investigate pool boiling heat transfer characteristics, such as critical heat flux (CHF) and boiling heat transfer coefficient (BHTC), of pure distilled water (d-H2O) and functionalised graphene nanoplatelet (f-GnPs)–d-H2O nanofluids using a nichrome (Ni-Cr) [...] Read more.
The present study aims to experimentally investigate pool boiling heat transfer characteristics, such as critical heat flux (CHF) and boiling heat transfer coefficient (BHTC), of pure distilled water (d-H2O) and functionalised graphene nanoplatelet (f-GnPs)–d-H2O nanofluids using a nichrome (Ni-Cr) test wire as the heating element. The distilled water (dH2O) and GnP (5–10 nm and 15 µm, Cheap Tubes, USA) were chosen as the base fluid and nanomaterial, respectively. The GnP was chemically functionalized and dispersed in dH2O using a probe sonicator. The nanofluids were characterized by measuring the zeta potential distribution and pH to ensure stability on day 1 and day 10 following preparation. The results show that the zeta potential values range from −31.6 mV to −30.6 mV, while the pH values range from 7.076 to 7.021 on day 1 and day 10, respectively. The novelty of the present study lies in the use of f-GnPs with a controlled size and stable nanofluid, confirmed through zeta potential and pH analysis, to determine the heat transfer behaviour of a Ni-Cr test wire under pool boiling conditions. The pool boiling heat transfer characteristics, such as CHF and BHTC, were observed using the fabricated pool boiling heat transfer test facility. Initially, the dH2O and f-GnP–dH2O nanofluids were separately placed in a glass container and heated using a pre-heater to reach their saturation point of 100 °C. The electrical energy was gradually increased until it reached the critical point of the Ni-Cr test wire, i.e., the burnout point, at which it became reddish-yellow hot. The CHF and BHTC were predicted from the experimental outputs of voltage and current. The results showed an enhancement of ~15% in the CHF at 0.1 vol% of f-GnPs. The present study offers a method for enhancing two-phase flow characteristics for heat pipe applications. Full article
Show Figures

Figure 1

15 pages, 4162 KB  
Article
Development of a Heating Block as an Aid for the DNA-Based Biosensing of Plant Pathogens
by Bertrand Michael L. Diola, Adrian A. Borja, Paolo Rommel P. Sanchez, Marynold V. Purificacion and Ralph Kristoffer B. Gallegos
Inventions 2025, 10(6), 94; https://doi.org/10.3390/inventions10060094 - 26 Oct 2025
Viewed by 1040
Abstract
Deoxyribonucleic acid (DNA)-based biosensors are rapid, cost-effective, and portable devices for monitoring crop pathogens. However, their on-field operations rely on a laboratory-bound heating block, which controls temperature during sample preparation. This study aimed to develop a field-deployable heating block to assist in the [...] Read more.
Deoxyribonucleic acid (DNA)-based biosensors are rapid, cost-effective, and portable devices for monitoring crop pathogens. However, their on-field operations rely on a laboratory-bound heating block, which controls temperature during sample preparation. This study aimed to develop a field-deployable heating block to assist in the DNA hybridization protocol of DNA-based biosensors. It should maintain 95 °C, 55 °C, and 20 °C for 5, 10, and 5 min, respectively. It had aluminum bars, positive thermal coefficient ceramic heaters, a Peltier thermoelectric module, and DS18B20 thermistors, serving twelve 0.2 mL polymerase chain reaction (PCR) tubes. An Arduino microcontroller employing a proportional–integral–derivative (PID) algorithm with a solid-state relay was utilized. Machine performance for distilled water-filled PCR tubes showed a maximum 10 °C thermal variation. The machine maintained (96.00±0.97) °C, (55.15±2.17) °C, and (17.75±0.71) °C with root mean square errors (RMSEs) of 1.40 °C, 2.18 °C, and 2.36 °C, respectively. The average thermal rates were (0.16±0.11) °C/s, (0.29±0.11) °C/s, and (0.14±0.07) °C/s from ambient to 95 °C, 95 °C to 55 °C, and 55 °C to 20 °C, respectively. Overall, the low standard deviations and RMSEs demonstrate thermostable results and robust temperature control. Full article
Show Figures

Figure 1

19 pages, 4775 KB  
Article
Experimental Study of the Cross-Influence of Frost Morphology and Defrost Strategy on the Performance of Tube-Fin Evaporators of Household Refrigerators
by Luiz P. B. Braun, Rodrigo G. Reis, Carlos A. R. Nascimento, Alexsandro S. Silveira and Christian J. L. Hermes
Thermo 2025, 5(3), 32; https://doi.org/10.3390/thermo5030032 - 2 Sep 2025
Cited by 1 | Viewed by 1506
Abstract
This study is aimed at evaluating the combined influence of running conditions that affect frost morphology and defrost strategies on the thermal-fluid-dynamic performance of tube-fin ‘no-frost’ evaporators. To this end, two purpose-built experimental apparatuses were designed and constructed, one based upon a fully [...] Read more.
This study is aimed at evaluating the combined influence of running conditions that affect frost morphology and defrost strategies on the thermal-fluid-dynamic performance of tube-fin ‘no-frost’ evaporators. To this end, two purpose-built experimental apparatuses were designed and constructed, one based upon a fully instrumented two-door bottom-mount ‘combi’ refrigerator with independent temperature and humidity control in both compartments, and another devised specifically for testing evaporator–heater assemblies under controlled frosting and defrosting cycles. Frost accumulation was studied for different surface temperatures and air humidity levels, revealing that higher humidity and lower surface temperatures led to lower frost density and thermal conductivity. Defrosting operations were analyzed for two different psychrometric conditions using three control strategies: step, ramp and pulse-width modulation (PWM). The ramp strategy yielded the highest defrost efficiency, reaching 36.7% in milder frost conditions, while the step strategy led to lower defrosting times. Such findings support the optimization of evaporator design and defrost strategies to improve energy efficiency in household refrigerating appliances. Full article
(This article belongs to the Special Issue Frosting and Icing)
Show Figures

Figure 1

24 pages, 8411 KB  
Article
Investigations on Solidification and Melting Processes of the Solar Salt Mixture in Evacuated and Non-Evacuated Receiver Tubes
by Valeria Russo, Giuseppe Napoli, Francesco Rovense, Primo Di Ascenzi, Gianremo Giorgi, Luigi Mongibello, Carmine Cancro, Gabriele Ciniglio and Walter Gaggioli
Energies 2025, 18(17), 4492; https://doi.org/10.3390/en18174492 - 23 Aug 2025
Cited by 1 | Viewed by 992
Abstract
Parabolic trough collector (PTC) plants that use solar salt as a heat transfer fluid face operational challenges due to the salt’s relatively high solidification temperature of around 240 °C, which can compromise reliability if solidification occurs within receiver tubes or piping. While electric [...] Read more.
Parabolic trough collector (PTC) plants that use solar salt as a heat transfer fluid face operational challenges due to the salt’s relatively high solidification temperature of around 240 °C, which can compromise reliability if solidification occurs within receiver tubes or piping. While electric tracing cables are typically used to heat piping, they cannot be installed on PTC receivers due to the presence of external glass covers. As an alternative, impedance heating can be employed, applying voltage directly to the steel receivers, which act as resistive heaters. This study presents experimental results on the phase-change behavior of solar salt within receivers, focusing on melting and solidification times. Tests were conducted using two dedicated receivers under vacuum and non-vacuum conditions. Under vacuum, complete melting was achieved at 4.5 V and 1.43 kW in 5.5 h, while solidification from 270 °C took about 4 h, progressing inward from the tube connections. For non-evacuated receivers, 7 V and 3.2 kW were needed for melting in 5.6 h, and solidification at 270 °C was completed in 1.45 h. These outcomes illustrate that non-evacuated tubes require nearly twice the power and have a 2.8-fold increase in heat loss rate, offering quantitative guidance for vacuum loss detection in PTC systems. Full article
(This article belongs to the Section A2: Solar Energy and Photovoltaic Systems)
Show Figures

Figure 1

17 pages, 483 KB  
Article
A New Model to Investigate Effect of Heat Conduction Between Tubes on Overall Performance of a Coil Absorber for Flat-Plate Solar Collectors
by Elena G. Martínez-Morales, Ricardo Romero-Méndez, Francisco G. Pérez-Gutiérrez and Pedro García-Zugasti
Energies 2025, 18(16), 4360; https://doi.org/10.3390/en18164360 - 15 Aug 2025
Viewed by 710
Abstract
Solar heaters are a sustainable solution to lower operating heating costs for diverse applications. Improving the design of these devices promotes the adoption of this technology to reduce the environmental impact of traditional gas water heaters. The present paper studies heat transfer along [...] Read more.
Solar heaters are a sustainable solution to lower operating heating costs for diverse applications. Improving the design of these devices promotes the adoption of this technology to reduce the environmental impact of traditional gas water heaters. The present paper studies heat transfer along the plate-fins of serpentine-type flat-plate solar collectors. The focus of this investigation is the analysis of tube-to-tube thermal conduction through the absorbent plate and its effect on the heat gain of the circulating fluid. The model used here does not consider the adiabatic boundary condition in the plate mid-distance between tubes but applies the prescribed temperatures of the tubes as a boundary condition for the plate-fins. This type of boundary condition allows for heat conduction between rows of tubes. The analysis demonstrates that tube-to-tube heat conduction along the absorber plate has a detrimental effect on the heat gain of the circulating fluid. This effect is responsible for a decrease of up to 10% of the circulating fluid heat gain. This investigation defines the set of parameters that affect the performance of plate solar heaters because of tube-to-tube thermal conduction along the plates, and it helps to choose operation and designs parameters, leading to better design of these devices. Full article
(This article belongs to the Section A2: Solar Energy and Photovoltaic Systems)
Show Figures

Figure 1

17 pages, 4160 KB  
Article
Experimental Investigation on Thermo-Economic Analysis of Direct Contact Membrane Distillation for Sustainable Freshwater Production
by Saleh M. Shalaby, Farid A. Hammad, Hamdy A. Ebeid, Asaad M. Armanuos, Iqbal M. Mujtaba and Tamer A. Gado
Processes 2025, 13(1), 240; https://doi.org/10.3390/pr13010240 - 15 Jan 2025
Cited by 1 | Viewed by 1880
Abstract
Treatment of extremely saline water such as the brine rejected from reverse osmosis water desalination plants, and produced water from shale oil and non-conventional gas extraction, is considered a global problem. Consequently, in this work, hollow fiber membrane distillation (HFMD) is experimentally evaluated [...] Read more.
Treatment of extremely saline water such as the brine rejected from reverse osmosis water desalination plants, and produced water from shale oil and non-conventional gas extraction, is considered a global problem. Consequently, in this work, hollow fiber membrane distillation (HFMD) is experimentally evaluated for desalinating extremely saline water of a salinity ranging from 40,000 to 130,000 ppm. For the purpose of comparison, the HFMD is also tested for desalinating brackish (3000–12,000 ppm) and sea (25,000–40,000 ppm) water. Firstly, the HFMD is tested at two values of feed water temperature (65 and 76 °C) and flow rate (600 and 850 L/h). The experimental results showed that the HFMD productivity significantly increases when the temperature of feed water increases. Increasing the feed water flow rate also has a positive effect on the productivity of HFMD. It is also concluded that the productivity of the HFMD is not significantly affected by increasing the salt concentration when brackish and sea water are used. The productivity also slightly decreases with increasing the salt concentration when extremely saline water is used. The decrement in the productivity reaches 27%, when the salt concentration increases from 40,000 to 130,000 ppm. Based on the conducted economic analysis, the HFMD shows a good potential for desalinating extremely saline water especially when the solar collector is used as a heat source. In this case, the cost per liter of freshwater is reduced by 21.7–23.1% when the evacuated tube solar collectors are used compared to the system using electrical heaters. More reduction in the cost per liter of freshwater is expected when a high capacity solar-powered HFMD plant is installed. Full article
(This article belongs to the Section Sustainable Processes)
Show Figures

Figure 1

11 pages, 3987 KB  
Article
A Rectangular Spiral Inward–Outward Alternating-Flow Polymer Thermal Collector for a Solar Water Heating System—A Preliminary Investigation in the Climate of Seri Iskandar, Malaysia
by Taib Iskandar Mohamad and Mohammad Danish Shareeman Mohd Shaifudeen
Appl. Sci. 2024, 14(23), 11045; https://doi.org/10.3390/app142311045 - 27 Nov 2024
Cited by 1 | Viewed by 1858
Abstract
A flat-plate unglazed solar water heater (SWH) with a polymer thermal absorber was developed and experimented with. Polymer thermal absorbers could be a viable alternative to metal thermal absorbers for SWH systems. The performance of this polymer SWH system was measured based on [...] Read more.
A flat-plate unglazed solar water heater (SWH) with a polymer thermal absorber was developed and experimented with. Polymer thermal absorbers could be a viable alternative to metal thermal absorbers for SWH systems. The performance of this polymer SWH system was measured based on inlet and outlet water temperature, water flow rate, ambient air temperature and solar irradiance. The polymer thermal absorbers were hollow Polyvinyl Chloride (PVC) tubes with a 20 mm external diameter and 3 mm thickness and were painted black to enhance radiation absorption. The pipes are arranged in a rectangular spiral inward–outward alternating-flow (RSioaf) pattern. The collector pipes were placed in a 1 m × 1 m enclosure with bottom insulation and a reflective surface for maximized radiation absorption. Water circulated through a closed loop with an uninsulated 16 L storage tank, driven by a pump and controlled by two valves to maintain a mass flow rate of 0.0031 to 0.0034 kg·s−1. The test was conducted under a partially clouded sky from 9 a.m. to 5 p.m., with solar irradiance between 105 and 1003 W·m−2 and an ambient air temperature of 27–36 °C. This SWH system produced outlet hot water at 65 °C by midday and maintained the storage temperature at 63 °C until the end of the test period. Photothermal energy conversion was recorded, showing a maximum value of 23%. Results indicate that a flat-plate solar water heater with a polymer thermal absorber in an RSioaf design can be an effective alternative to an SWH with a metal thermal absorber. Its performance can be improved with glazing and optimized tube sizing. Full article
(This article belongs to the Special Issue Advanced Solar Energy Materials: Methods and Applications)
Show Figures

Figure 1

41 pages, 21982 KB  
Article
Method for Calculating Heat Transfer in a Heat Accumulator Using a Phase Change Material with Intensification Due to Longitudinal Fins
by Vladimir Lebedev, Andrey Deev and Konstantin Deev
Energies 2024, 17(21), 5281; https://doi.org/10.3390/en17215281 - 24 Oct 2024
Cited by 1 | Viewed by 2076
Abstract
One of the challenges in energy supply for isolated power systems is maintaining a steady balance between generated and consumed energy. The application of energy storage systems and flexible energy sources is the most preferable approach for these systems. Small- and medium-sized nuclear [...] Read more.
One of the challenges in energy supply for isolated power systems is maintaining a steady balance between generated and consumed energy. The application of energy storage systems and flexible energy sources is the most preferable approach for these systems. Small- and medium-sized nuclear power plants are promising, carbon-free options for energy supply to isolated power systems. However, these plants have low maneuverability. To solve this problem, this article discusses the use of a thermal accumulator using a phase change material (solar salt) to heat feedwater. Tubes with longitudinal fins are used to intensify heat transfer in the storage system. This paper presents a method for calculating heat transfer along the entire heat exchange surface of such an accumulator. A series of 2D simulations were conducted to study the solidification process of solar salt around a heat exchange tube at various temperatures on the inner wall surface. The regression dependences of heat transfer on the temperature of the inner surface of the wall and the thickness of the solid PCM layer were determined. Using the presented method and the obtained regression dependencies, we determined the time graphs of the temperature change in the heat transfer fluid at the outlet of the accumulator during discharge. Based on the results presented, it was found that an accumulator with 72.7 tons of solar salt (dimensions: 6 × 3.71 × 2.15 m) can replace a high-pressure heater №1 at a low-power nuclear power plant (50 MW) during 3450 s. Full article
(This article belongs to the Special Issue Review Papers in Energy Storage and Related Applications)
Show Figures

Figure 1

23 pages, 7493 KB  
Article
Heating Industrial Buildings with Heat Pump Air Systems: Is It Always the Most Advantageous Option?
by Marco Noro
Energies 2024, 17(20), 5209; https://doi.org/10.3390/en17205209 - 19 Oct 2024
Viewed by 1869
Abstract
According to extant Italian legislation implementing the Renewable Energy Directive, the mandatory renewable quota for a new building is 60% referring to a single service (e.g., heating during winter) or to multiple services (e.g., heating during winter and air conditioning during summer), depending [...] Read more.
According to extant Italian legislation implementing the Renewable Energy Directive, the mandatory renewable quota for a new building is 60% referring to a single service (e.g., heating during winter) or to multiple services (e.g., heating during winter and air conditioning during summer), depending on which services are actually present. The obligation to satisfy this minimum value often leads heating and ventilation plant designers to provide heat pump systems in industrial buildings, typically air/water or direct expansion type coupled with air terminals (air heaters or ventilation units) or radiant floors. The question is: Is this always the most advantageous option for industrial buildings? A typical industrial building was modeled by Trnsys® in two different climates. Based on the calculated thermal heating loads, the condensing radiant tubes and heat pump coupled with the air heaters systems were analyzed through dynamic simulation, evaluating their performance from an energy, environmental impact, and economic point of view. The analysis carried out revealed that a heat pump system is not always the most advantageous solution depending on the climate, the characteristics of the building (less or more thermal insulation, which corresponds to existing buildings rather than new ones), and the size of the photovoltaics system eventually installed on the roof. Full article
(This article belongs to the Special Issue Performance Analysis of Building Energy Efficiency)
Show Figures

Figure 1

10 pages, 1738 KB  
Article
Post-Forming of Carbon Fibre-Reinforced PEEK Thermoplastic Tubular Structures
by Mengyuan Li, Chris Stokes-Griffin and Paul Compston
J. Compos. Sci. 2024, 8(9), 335; https://doi.org/10.3390/jcs8090335 - 23 Aug 2024
Cited by 3 | Viewed by 2220
Abstract
This paper presents a post-forming technique utilising both induction heating and rotary draw bending (RDB) for carbon fibre-reinforced polyetherentherketone (CF/PEEK) tubular structures. Existing post-forming techniques are unable to form CF/PEEK tubes due to the lack of a suitable mandrel material to provide internal [...] Read more.
This paper presents a post-forming technique utilising both induction heating and rotary draw bending (RDB) for carbon fibre-reinforced polyetherentherketone (CF/PEEK) tubular structures. Existing post-forming techniques are unable to form CF/PEEK tubes due to the lack of a suitable mandrel material to provide internal support to the tube while withstanding high heat from melting the PEEK matrix during forming. This is addressed by using a steel spring mandrel in the tube induction heating process. In this study, four sets of [±60°]4 CF/PEEK tubes were formed using an induction heater-incorporated RDB setup into 45°, 90°, 135°, and 180° bends with a bending ratio of 2. Optical characterisation was performed to analyse tube fibre angle changes. A post-forming fibre angle prediction model previously derived for CF/polyamide 6 tubes was validated for its application in predicting fibre angle changes for CF/PEEK tubes by comparing the prediction with the characterised results. Full article
(This article belongs to the Section Composites Manufacturing and Processing)
Show Figures

Figure 1

10 pages, 1978 KB  
Article
Flow Rate Sensor inside Infusion Tube
by Hsiang-Chen Chui, Ying Xu, Zhiyuan Wang, Xianting Zhang, Rui Li and Kai-Rong Qin
Inventions 2024, 9(4), 89; https://doi.org/10.3390/inventions9040089 - 13 Aug 2024
Cited by 3 | Viewed by 4056
Abstract
Infusion systems are widely used in clinical medicine. Intravenous infusion therapy must be monitored to ensure patient safety. We proposed a compact flow rate sensor device based on the time-of-flight method. This device included one ceramic heater and two infrared sensors. Practical sensor [...] Read more.
Infusion systems are widely used in clinical medicine. Intravenous infusion therapy must be monitored to ensure patient safety. We proposed a compact flow rate sensor device based on the time-of-flight method. This device included one ceramic heater and two infrared sensors. Practical sensor prototypes were fabricated and characterized. The response time was 30 s. The sensor range was estimated to be 33 dB from μL/min to tens of mL/min, covering almost the entire usage range This flow rate sensor can be applied to common infusion tubes. Through the use of a mobile phone app, detailed information can be presented in real time. Full article
Show Figures

Figure 1

24 pages, 7411 KB  
Article
Design, Simulation and Optimization of a Novel Transpired Tubular Solar Air Heater
by Hossain Nemati
Energies 2024, 17(10), 2323; https://doi.org/10.3390/en17102323 - 11 May 2024
Cited by 2 | Viewed by 1669
Abstract
In this paper, a novel tubular solar air heater is introduced. In this air heater, the hot boundary layer is drawn into the absorber tube and can provide thermal energy at moderate temperatures. Several different cases were simulated and a correlation was proposed [...] Read more.
In this paper, a novel tubular solar air heater is introduced. In this air heater, the hot boundary layer is drawn into the absorber tube and can provide thermal energy at moderate temperatures. Several different cases were simulated and a correlation was proposed to predict the collector’s effectiveness as a function Rayleigh number and Reynolds number. An equation was derived to find the effectiveness of this collector. Finally, a real case was studied with non-uniform solar flux distribution, as well as radiation heat loss. Good agreement was found between the results and those derived by the proposed analytical method. For different suction values, the first-law and the second-law efficiencies were calculated. Based on the exergy analysis, exergy destruction in absorption is the dominant factor that is unavoidable in low-temperature collectors. It was shown that there is an optimum suction value at which the second-law efficiency is maximized. At the optimum point, temperature rise can reach 54 K, which is hardly possible with a flat plate collector. Based on the exergy analysis, the relation between tube wall temperature and air outlet temperature in their dimensionless forms at the optimum working condition was derived, and it was shown that effectiveness at the optimum working condition is around 0.5. This means that the air temperature rise shall be half of the temperature difference between collector wall and the ambient temperatures. A high outlet temperature besides the low cost of construction and maintenance are the main advantages of this air heater. With such a high temperature rise, this type of collector can increase the use of solar energy in domestic applications. Full article
(This article belongs to the Topic Advances in Solar Heating and Cooling)
Show Figures

Figure 1

Back to TopTop