Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (19)

Search Parameters:
Keywords = telescopic crown

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
18 pages, 2810 KB  
Case Report
Maxillary Resection Prosthesis Retained by Telescopic Crowns and a Rotational Latching Mechanism: A Case Report
by Panagiota Chatzidou, Savvas Kamalakidis, John Fanourgiakis, Mathildi Tsekou and Olga Naka
Surgeries 2026, 7(2), 62; https://doi.org/10.3390/surgeries7020062 - 24 May 2026
Viewed by 539
Abstract
Context: Prosthetic rehabilitation of acquired maxillary defects with Maxillary Resection Prostheses (MRPs) remains biomechanically challenging, particularly in partially edentulous patients, where conventional clasp-retained designs often yield suboptimal retention, stability, and functional outcomes. Research Gap: The integration of telescopic crown systems with semi-precision attachments [...] Read more.
Context: Prosthetic rehabilitation of acquired maxillary defects with Maxillary Resection Prostheses (MRPs) remains biomechanically challenging, particularly in partially edentulous patients, where conventional clasp-retained designs often yield suboptimal retention, stability, and functional outcomes. Research Gap: The integration of telescopic crown systems with semi-precision attachments incorporating a rotational latching mechanism has not been previously described as a unified approach to optimise load distribution and prosthesis stability in maxillary defect rehabilitation. Objective: To describe and clinically evaluate a novel prosthetic design combining telescopic crowns and a semi-precision rotational latching attachment to enhance retention, stability, and functional performance of MRPs. Methodology: A 31-year-old patient with a unilateral maxillary defect following partial maxillectomy presented with an unstable interim prosthesis and impaired speech and mastication. A definitive MRP was designed using telescopic crowns on the remaining dentition to establish a controlled path of insertion and improved axial load transfer. A semi-precision attachment with a key–keyway rotational latching mechanism was incorporated into the secondary framework to engage specific undercuts while minimising lateral forces on abutment teeth. A provisional prosthesis was used for 3 months to evaluate base extension, phonetics, and functional parameters before fabrication of the definitive prosthesis. Results: Serial follow-up at 1, 3, and 6 months demonstrate consistent prosthesis stability, precise seating, and favourable retention. Marked improvements were observed in speech intelligibility, masticatory efficiency, and patient-reported comfort. Conclusions: This combined prosthetic strategy represents a novel and biomechanically optimised approach for the rehabilitation of partially edentulous maxillary defects, with promising clinical and functional outcomes. Full article
(This article belongs to the Section Oral and Maxillofacial Surgery)
Show Figures

Figure 1

11 pages, 1450 KB  
Article
Post and Core for Telescopic Crown-Retained Dentures—An In Vitro Comparison of Different Materials Using Chewing Simulation
by Jonas Adrian Helmut Vogler, Milan Rachold, Bernd Wöstmann, Peter Rehmann and Kay-Arne Walther
Dent. J. 2026, 14(4), 233; https://doi.org/10.3390/dj14040233 - 14 Apr 2026
Viewed by 1100
Abstract
Objectives: Due to extra-axial forces, post and core (PC) treatment has the worst survival probability in abutment teeth for telescopic crown-retained dentures (TCDs). The reason for this is a mismatch regarding the mechanical properties between PC material and dentin or a poor accuracy [...] Read more.
Objectives: Due to extra-axial forces, post and core (PC) treatment has the worst survival probability in abutment teeth for telescopic crown-retained dentures (TCDs). The reason for this is a mismatch regarding the mechanical properties between PC material and dentin or a poor accuracy of fit of PC, resulting in tooth fracture or decementation. However, the inclusion of severely damaged endodontically treated teeth needing PC is often mandatory in order to achieve a stable situation for TCD. Thus, an advancement of PC treatment for TCD is of high clinical interest. Recently it has become possible to fabricate customized PC with favourable mechanical properties by using CAD/CAM technology. Methods: Thus, the aim of this investigation was to compare the performance of these PC types (CAD/CAM PC) to customized cast PC (CPC) and prefabricated fibre-reinforced PC (PFPC) in a TCD set-up using a chewing simulator. Results: The investigation group with CAD/CAM PC showed neither tooth fracture nor decementation, in contrast to the CPC and PFPC groups, in which both types of failure were recorded. Thus, CAD/CAM PC showed significantly better performance than CPC and PFPC. Conclusions: Within the limitations, CAD/CAM PCs are therefore recommendable for PC treatment with TCD. Full article
(This article belongs to the Section Digital Technologies)
Show Figures

Graphical abstract

18 pages, 13809 KB  
Case Report
Restorations with Zirconia Fixed Bridges over One-Piece Zirconia Implants and PEEK Telescopic Crowns: A Mini-Review and Case Report
by Haseeb H. Al Dary, Layla A. Abu-Naba’a, Hussein H. Helal and Mahmoud M. Hasasna
Prosthesis 2025, 7(6), 145; https://doi.org/10.3390/prosthesis7060145 - 10 Nov 2025
Viewed by 2401
Abstract
Ceramic dental implants, particularly one-piece zirconia, offer a biocompatible and aesthetic alternative to titanium, with high strength and improved oral hygiene. By eliminating the implant–abutment micro-gap, they reduce bacterial accumulation because of their low plaque affinity and enhance stability. However, challenges remain, including [...] Read more.
Ceramic dental implants, particularly one-piece zirconia, offer a biocompatible and aesthetic alternative to titanium, with high strength and improved oral hygiene. By eliminating the implant–abutment micro-gap, they reduce bacterial accumulation because of their low plaque affinity and enhance stability. However, challenges remain, including alignment precision, limited retrievability, and sensitivity to mechanical stress. Misalignment can affect occlusal and functional outcomes, and zirconia’s rigidity complicates crown removal and modification. This case report explores the use of PEEK (polyether ether ketone) primary telescopic crowns to overcome these limitations, improving force distribution, enabling minor adjustments, and enhancing prosthetic retrievability in full-mouth zirconia restorations. A 62-year-old male patient seeking a fixed solution to replace removable dentures received 16 one-piece zirconia implants (eight per jaw). PEEK telescopic crowns were used over implant abutment copings, finalized with aesthetic zirconia bridges. The report details surgical and prosthetic procedures, along with a brief literature review on zirconia implants and PEEK applications. PEEK integration in telescopic prosthetic designs marks a notable advancement in prosthodontics. Its shock-absorbing, biocompatible, and stress-modulating properties make it valuable for implant-supported and hybrid restorations. As digital workflows advance, PEEK-based telescopic restorations may increasingly replace traditional metal-based solutions, improving long-term clinical outcomes. Further clinical research on a larger sample is needed. Full article
(This article belongs to the Special Issue Advancements in Zirconia Dental Restorations)
Show Figures

Figure 1

13 pages, 4227 KB  
Article
Wear Measurements in Cylindrical Telescopic Crowns Using an Active Piezoresistive Cantilever with an Integrated Gold Microsphere Probe
by Tomasz Dąbrowa, Dominik Badura, Bartosz Pruchnik, Władysław Kopczyński, Ivo W. Rangelow, Edward Kijak and Teodor Gotszalk
Materials 2025, 18(19), 4624; https://doi.org/10.3390/ma18194624 - 7 Oct 2025
Viewed by 1228
Abstract
In this paper, we report a novel application of atomic force microscopy (AFM) for measurement of wear of prosthetic materials. In contrast to previously employed methods, we introduce AFM-based wear induction. In this way, we utilize AFM as both measurement technique and the [...] Read more.
In this paper, we report a novel application of atomic force microscopy (AFM) for measurement of wear of prosthetic materials. In contrast to previously employed methods, we introduce AFM-based wear induction. In this way, we utilize AFM as both measurement technique and the mean for surface wear. We describe the methodology along with the metrological advantages of the approach regarding the supreme resolution of volume measurement (down to 1 μm3). We investigate wear between prosthetic gold alloy (Degulor M) and FGP polymeric material from Bredent in nanoscale. For that purpose, we modify active piezoresistive cantilever, replacing the original tip with Degulor M microsphere. We elaborate on the process of modification and present how the mass volume and topology of the tip is controlled throughout the process. Wear process was performed in reciprocal motion over the length of 5 μm in 35,000 repetitions to mimic the actual conditions occurring in human mouth cavity. We present how this method, by focusing on a small area of investigated materials, leads to shortening the overall time of wear measurements from tong term observations down to several minutes. AFM-measured data present consistent relation between wear energy and wear volume. Exemplary results seem to confirm durability of the FGP-Degulor M mechanical contact and occurring strengthening of the mechanical contact with roughening of the polymeric surface. Full article
Show Figures

Figure 1

15 pages, 5462 KB  
Article
Contemporary Magnetic Removable Partial Denture Utilizing a Novel Ultra-Thin Magnetic Attachment System
by Adityakrisna Yoshi Putra Wigianto, Yuichi Ishida, Kohei Kamoi, Takaharu Goto, Kazumitsu Sekine, Megumi Watanabe and Tetsuo Ichikawa
Dent. J. 2025, 13(7), 278; https://doi.org/10.3390/dj13070278 - 20 Jun 2025
Viewed by 2831
Abstract
Background/Objectives: Recently, a novel magnetic attachment system was introduced to improve performance. Using the same technology, a new ultra-thin magnetic attachment (UTMA) was possible to produce. This study aimed to evaluate the feasibility of a magnet-retained telescopic partial denture (MTPD) utilizing the new [...] Read more.
Background/Objectives: Recently, a novel magnetic attachment system was introduced to improve performance. Using the same technology, a new ultra-thin magnetic attachment (UTMA) was possible to produce. This study aimed to evaluate the feasibility of a magnet-retained telescopic partial denture (MTPD) utilizing the new UTMA. Methods: This in vitro study was performed using a titanium master model representing prepared lower first-premolar and second-molar abutment teeth. The inner crowns (ICs) (h: 4 mm, 4° taper) and four-unit MTPDs were fabricated via computer-aided design/computer-aided manufacturing (CAD/CAM) using zirconia. A Ø4 mm UTMA system (magnet assembly and keeper thickness: 0.6 mm and 0.4 mm, respectively) was cemented into the MTPD and the ICs using dual-cure resin cement. A load of 100 N was applied along with 10,000 insertion–removal cycles. The MTPD retentive force was measured before and after every set of 1000 cycles. Stability tests and surface morphology evaluations were conducted before and after cycling. A paired t-test (α = 0.05) was used to observe statistical differences. Results: The average retentive force of the MTPD was 6.86 ± 0.63 N and did not change significantly (p > 0.05) following the load cycles (6.66 ± 0.79 N). The MTPD demonstrated adequate stability under the occlusal load. Minimal deformations were observed on the magnet assemblies, keepers, ICs, and MTPD surfaces after the load tests. Conclusions: Considering the limitations of this study, an MTPD utilizing novel UTMAs fabricated through a digital workflow demonstrated adequate retentive force, stability, and durability for clinical use. Full article
(This article belongs to the Special Issue Digital Dentures: 2nd Edition)
Show Figures

Figure 1

8 pages, 441 KB  
Article
Post and Core Treatment to Refit Telescopic Crown-Retained Dentures after Abutment Tooth Fracture: An Evaluation of Therapy by Retrospective Survival Analysis
by Jonas Adrian Helmut Vogler, William Abrahamian, Sarah Marie Reich, Bernd Wöstmann and Peter Rehmann
Dent. J. 2024, 12(7), 224; https://doi.org/10.3390/dj12070224 - 19 Jul 2024
Cited by 1 | Viewed by 4078
Abstract
Telescopic crown-retained dentures (TCDs) are one of the most common types of prosthetic restorations for partially edentulous patients; however, post and core (PC) treatment shows the worst survival probability if the tooth is used as an abutment for the TCD. Due to extra [...] Read more.
Telescopic crown-retained dentures (TCDs) are one of the most common types of prosthetic restorations for partially edentulous patients; however, post and core (PC) treatment shows the worst survival probability if the tooth is used as an abutment for the TCD. Due to extra axial forces, abutment tooth fracture is a common cause of failure for TCDs; thus, PC treatment is often needed to refit the existing telescopic crown (TC). However, there are no clinical survival data on whether the PC treatment was used to refit the TC after abutment tooth fracture (PC2) or the PC was already fitted at the time of TCD treatment (PC1). A total of 246 patients with 399 PC treatments were retrospectively evaluated for follow-ups up to 17.33 years. The files were analysed for PC1 and PC2. Furthermore, the influence of the jaw, type of tooth, luting material, PC material, bone attachment, therapist and cause of failure was recorded. For statistical analysis, Kaplan–Meier and Cox regression analyses were conducted. PC2 showed highly significant lower survival probabilities than PC1 (p < 0.001). Moreover, the bone attachment and the age of the patient at the time of fitting the PC crown had an influence on the survival (p < 0.001). Therefore, PC2 should be carefully discussed with the patient and PC1 should be favoured in endodontically treated abutment teeth for TCDs. Full article
Show Figures

Graphical abstract

15 pages, 2529 KB  
Article
Implant-Supported Overdentures: Current Status and Preclinical Testing of a Novel Attachment System
by Frank Wendler, Lisa Diehl, Pejman Shayanfard and Matthias Karl
J. Clin. Med. 2023, 12(3), 1012; https://doi.org/10.3390/jcm12031012 - 28 Jan 2023
Cited by 10 | Viewed by 5623
Abstract
Numerous attachment systems exist for implant-supported overdentures, with each having specific limitations in terms of retention, cost, wear, maintenance and cleanability. A retrospective analysis of patients restored with implant-supported overdentures using bars, telescopic crowns and Locator-type attachments was performed and the patients were [...] Read more.
Numerous attachment systems exist for implant-supported overdentures, with each having specific limitations in terms of retention, cost, wear, maintenance and cleanability. A retrospective analysis of patients restored with implant-supported overdentures using bars, telescopic crowns and Locator-type attachments was performed and the patients were interviewed. An in vitro strain gauge study compared telescopic crowns, Locator-type attachments and a novel flexible attachment system employing a shape memory alloy (NiTi) with respect to peri-implant strain development during insertion, loading and removal of an overdenture. A significantly lower number of attachment-related complications was observed in bars as compared to telescopic crowns (p = 0.00007) and Locator-type attachments (p = 0.00000), respectively. Greater overall patient satisfaction was noted in bar-retained restorations while Locator-type attachments led to lower levels of satisfaction regarding prosthesis retention. In vitro, telescopic crowns caused maximum strain development during prosthesis insertion and loading, while during removal this was observed in Locators with white retentive inserts. NiTi attachments caused significantly lower strain development during insertion as compared to telescopic crowns (p = 0.027). During loading, NiTi attachments caused significantly lower strain development than Locators with blue retentive inserts (p = 0.039). During removal, NiTi attachments caused significantly less strain development as compared to Locators with white retentive inserts (p = 0.027). Positional discrepancies between male and female attachment parts affected the retention and reaction force between both components, which may be minimized by using the novel NiTi attachment system. This may be beneficial in terms of component wear and implant loading. Full article
Show Figures

Figure 1

17 pages, 7343 KB  
Article
Dual-Manipulator Optimal Design for Apple Robotic Harvesting
by Zicong Xiong, Qingchun Feng, Tao Li, Feng Xie, Cheng Liu, Le Liu, Xin Guo and Chunjiang Zhao
Agronomy 2022, 12(12), 3128; https://doi.org/10.3390/agronomy12123128 - 9 Dec 2022
Cited by 29 | Viewed by 5344
Abstract
In order to ensure canopy area coverage with the most compact mechanical configuration possible, this paper proposes a configuration optimization design method of dual-manipulator to meet the research and development needs of an apple-efficient harvesting robot using the typical tree shape of a [...] Read more.
In order to ensure canopy area coverage with the most compact mechanical configuration possible, this paper proposes a configuration optimization design method of dual-manipulator to meet the research and development needs of an apple-efficient harvesting robot using the typical tree shape of a “high spindle” in China as the object. A Cartesian coordinate dual-manipulator with two groups of vertically synchronous operations and a three-degree range of motion based on the features of the spatial distribution of fruits under a typical canopy of dwarf and close planting was designed. Two-stage telescoping components that can be driven by both gas and electricity are employed to ensure the picking robotic arm’s quick response and accessibility to the tree crown. Based on the quantitative description of the working space and configuration parameters of the dual-manipulator, a multi-objective optimization model of the major configuration parameters is constructed. A comprehensive evaluation method of the dual-manipulator configuration based on the CRITIC–TOPSIS combined method is proposed. The optimal solutions of the lengths and elevations of upper and lower telescopic parts of the dual-manipulator and the distance from the mounting base of the outer frame of the dual-manipulator to the center of the tree trunk are determined, which are 1119.3 mm and 39.4°, 898.7 mm and 26°, 755.3 mm, respectively. The interaction between the configuration parameters of the dual-manipulator and its working area is then simulated and examined in order to verify the rationality of the optimum configuration settings. The results show that the optimal configuration of the dual-manipulator can fully cover the target working space, and the redundancy rate is 16.62%. The results of this study can be utilized to advance robotic fruit-picking research and development. Full article
(This article belongs to the Special Issue Agricultural Unmanned Systems: Empowering Agriculture with Automation)
Show Figures

Figure 1

13 pages, 578 KB  
Article
Non-Precious Metal Alloy Double Crown-Retained Removable Partial Dentures: A Cross-Sectional In Vivo Investigation
by Malin Strasding, Samir Abou-Ayash, Thomas Laziok, Sam Doerken, Ralf-Joachim Kohal and Sebastian Berthold Maximilian Patzelt
Materials 2022, 15(17), 6137; https://doi.org/10.3390/ma15176137 - 4 Sep 2022
Cited by 6 | Viewed by 3090
Abstract
(1) Background: An alternative material to precious metal alloys are non-precious metal alloys. The material properties of these are different and, therefore, their clinical, biological and mechanical behaviors may also differ. Hence, the purpose of this in vivo investigation was to analyze the [...] Read more.
(1) Background: An alternative material to precious metal alloys are non-precious metal alloys. The material properties of these are different and, therefore, their clinical, biological and mechanical behaviors may also differ. Hence, the purpose of this in vivo investigation was to analyze the clinical and patient-reported outcomes of patients restored with non-precious metal alloy double crown-retained removable partial dentures (NP-D-RPDs). (2) Methods: Partially edentulous patients were restored with non-precious metal alloy partially veneered NP-D-RPDs. Survival rates, success rates, failures and patient-reported outcomes were investigated and statistically evaluated. (3) Results: A total of 61 patients (65.6 ± 10.8 years) were included and clinically and radiographically examined. The mean follow-up time was 25.2 ± 16.5 months. In total, 82 NP-D-RPDs and 268 abutment teeth were examined. The overall survival rate of the NP-D-RPDs was 100% after a mean follow-up time of 2.1 years. The overall success rate was 68.3%. The overall satisfaction with the NP-D-RPDs was 94.3%. (4) Conclusions: Non-precious metal alloy partially veneered NP-D-RPDs seem to be an efficient alternative to precious metal alloy RPDs with excellent patient-reported outcomes. Full article
(This article belongs to the Section Metals and Alloys)
Show Figures

Figure 1

13 pages, 2911 KB  
Article
Comparative Stress Analysis of Polyetherketoneketone (PEKK) Telescopic Crowns Supported by Different Primary Crown Materials
by João Paulo Mendes Tribst, Amanda Maria de Oliveira Dal Piva, Azeem Ul Yaqin Syed, Mohammed Alrabiah, Khulud A. Al-Aali, Fahim Vohra and Tariq Abduljabbar
Appl. Sci. 2022, 12(7), 3446; https://doi.org/10.3390/app12073446 - 28 Mar 2022
Cited by 7 | Viewed by 3845
Abstract
The present study aimed to investigate the stress distribution of secondary telescopic crowns made of polyetherketoneketone (PEKK) combined with different primary crown (PC) materials (Zirconia, CoCr, Titanium, and PEKK) using finite element analysis. The geometric model was composed of bone tissue, periodontal ligament, [...] Read more.
The present study aimed to investigate the stress distribution of secondary telescopic crowns made of polyetherketoneketone (PEKK) combined with different primary crown (PC) materials (Zirconia, CoCr, Titanium, and PEKK) using finite element analysis. The geometric model was composed of bone tissue, periodontal ligament, root dentin, cement layer, primary crown, and secondary telescopic crown (SC). A total of four models were evaluated in which the secondary crowns were simulated in PEKK. The models were designed in CAD software and exported to the computer aided engineering software for the statistic structural analysis simulation. The materials were considered isotropic, with linear behavior and elastic properties. The model was fixed in the bone base and the load was applied at the occlusal surface of the crowns with 600 N. The results were required in von-Mises stress for the primary crown, secondary crown, cement layer, and Equivalent Strain to the periodontal ligament and bone tissue. Results show that the material influenced the stress distribution. The higher the PC elastic modulus, the higher the stress magnitude on the SC and cement layer. In the present study, the use of milled high-density polymer for primary crown presented a promising biomechanical behavior as an alternative material for double-crown design. Full article
Show Figures

Figure 1

9 pages, 6000 KB  
Case Report
Digitally Fabricated Dentures for Full Mouth Rehabilitation with Zirconia, Polyetheretherketone and Selective Laser Melted Ti-6Al-4V Material
by Wei-Ting Lee and Yung-Chung Chen
Int. J. Environ. Res. Public Health 2022, 19(5), 3021; https://doi.org/10.3390/ijerph19053021 - 4 Mar 2022
Cited by 6 | Viewed by 4626
Abstract
CAD/CAM technologies have been embedded into the fabrication of removable partial denture (RPD). Various materials such as zirconia and polyetheretherketone (PEEK) are developed for subtractive manufacturing. As for additive manufacturing, dental professionals have begun to use selective laser melting (SLM) techniques for fabricating [...] Read more.
CAD/CAM technologies have been embedded into the fabrication of removable partial denture (RPD). Various materials such as zirconia and polyetheretherketone (PEEK) are developed for subtractive manufacturing. As for additive manufacturing, dental professionals have begun to use selective laser melting (SLM) techniques for fabricating metallic RPD frameworks. This report demonstrates a case rehabilitated with a maxillary telescopic crown-retained combining PEEK and zirconia material denture and a mandibular Kennedy Class I RPD fabricated with SLM techniques. First, a conventional impression was performed and the master cast was mounted with a centric relation record. Digital models were obtained using tabletop scanners and then the telescopic primary zirconia crowns were designed and milled. After transferring the intraoral distribution of primary crowns using pick-up impression, secondary PEEK crowns and framework were designed, milled, and veneered with composite resin. Mandibular framework was designed and constructed using SLM technique with Ti-6Al-4V. Definitive prostheses for both jaws were finished and delivered. Delivered prostheses functioned well for a one-year period. The was patient satisfied with the improvements in chewing function and esthetics. Both substrative and additive manufacturing techniques are suitable for framework fabrication. Further investigation is needed for improving the mechanical performance and long-term prognosis of digitally made prostheses. Full article
(This article belongs to the Special Issue Digital Dentistry, Implantology and Maxillo-Facial Diseases)
Show Figures

Figure 1

10 pages, 552 KB  
Article
Survival of Fiber-Reinforced Composite Resin Post-Restored vs. Cast Post-and-Core-Restored Teeth: A Retrospective Clinical Study
by Oskar Bunz, Darja Iwantschenko, Sabrina Tulka, Claudia Barthel-Zimmer and Andree Piwowarczyk
Oral 2021, 1(4), 340-349; https://doi.org/10.3390/oral1040034 - 14 Dec 2021
Cited by 1 | Viewed by 8329
Abstract
Objective: The question of whether classic cast post-and-core (CPC) or fiber-reinforced composite resin posts (FRCP) are the best clinical decision has still not been fully solved. Materials and Methods: One hundred and sixty-two teeth were restored with FRCP, and 162 CPC restored teeth [...] Read more.
Objective: The question of whether classic cast post-and-core (CPC) or fiber-reinforced composite resin posts (FRCP) are the best clinical decision has still not been fully solved. Materials and Methods: One hundred and sixty-two teeth were restored with FRCP, and 162 CPC restored teeth were included in this study with a matched-pair design. In a primary analysis, the survival rates after one year (primary endpoint) were compared. The additional analysis included an evaluation of tooth- and construction-specific variables and an illustration of the survival up to 60 months via Kaplan-Meier curves. Results: FRCP showed lower failure risk considering the definitive prosthetic restoration and tooth type compared to CPC restored teeth. In total, 17 failures were observed in the FRCP group and 35 failures in the CPC group. A 60-month survival rate of 79.3% for FRCP and 64.5% for CPC was observed. Teeth serving as abutments for telescopic dentures were more likely to be affected by failure compared to teeth restored with single crowns. Conclusion: Within the limitations of this study, the FRCP showed a lower failure risk compared to the CPC, considering the definitive prosthetic restoration and tooth type within the observation period. Full article
Show Figures

Figure 1

19 pages, 879 KB  
Review
Parameters Affecting the Retention Force of CAD/CAM Telescopic Crowns: A Focused Review of In Vitro Studies
by Abdullah Kamel, Amr Badr, Gehan Fekry and James Tsoi
J. Clin. Med. 2021, 10(19), 4429; https://doi.org/10.3390/jcm10194429 - 27 Sep 2021
Cited by 15 | Viewed by 4647
Abstract
Telescopic systems constructed using computer aided design and computer aided manufacture (CAD/CAM) can overcome many drawbacks associated with conventionally constructed ones. Since retention is considered the most important function of these retainers, this scoping review aimed to discuss and summarize the parameters that [...] Read more.
Telescopic systems constructed using computer aided design and computer aided manufacture (CAD/CAM) can overcome many drawbacks associated with conventionally constructed ones. Since retention is considered the most important function of these retainers, this scoping review aimed to discuss and summarize the parameters that affect this function in CAD/CAM-manufactured telescopic crowns and to compare their retention force values with the recommended retention force. An electronic search was done in Pubmed and Google Scholar databases using different keyword combinations to find the related articles. Seventeen articles that follow the eligibility criteria for this review were selected and analyzed for detection of each of the tested parameters and their effect on retention force. The parameters tested in these articles were divided into parameters related to design, manufacturing, material type, and test condition. Regardless of the effect of these parameters, the retention force values recorded in most of the selected studies laid within or were higher than the recommended retention force (2.5–10 N), which indicated the need to design and set the combination of materials of telescopic systems according to oral biomechanics. Full article
(This article belongs to the Section Dentistry, Oral Surgery and Oral Medicine)
Show Figures

Figure 1

16 pages, 2698 KB  
Article
Assessment of Force Retention between Milled Metallic and Ceramic Telescopic Crowns with Different Taper Angles Used for Oral Rehabilitation
by Caroline Adela Ingrid Fischer, Doina Lucia Ghergic, Diana Maria Vranceanu, Stefan Alexandru Ilas, Raluca Monica Comaneanu, Florin Baciu and Cosmin Mihai Cotrut
Materials 2020, 13(21), 4814; https://doi.org/10.3390/ma13214814 - 28 Oct 2020
Cited by 10 | Viewed by 4118
Abstract
The present study assessed the retention forces corresponding to different telescopic systems used in removable prosthetic dentures. The telescopic systems were represented by Co–Cr alloy or zirconia-based primary crowns and Co–Cr secondary crowns. All crowns were manufactured using computer-aided design/computer-aided manufacturing technology (CAD/CAM). [...] Read more.
The present study assessed the retention forces corresponding to different telescopic systems used in removable prosthetic dentures. The telescopic systems were represented by Co–Cr alloy or zirconia-based primary crowns and Co–Cr secondary crowns. All crowns were manufactured using computer-aided design/computer-aided manufacturing technology (CAD/CAM). Two types of reference abutment teeth (upper canine and first upper molar) were selected in order to obtain the telescopic crowns and two taper angles—of 0° and 2°—were used for the design of the crowns. A number of 120 samples of telescopic crowns were obtained and subjected to mechanical tests, following a specific protocol, on a mechanical testing equipment. The retention of the telescopic systems was evaluated for different sets of cycles (up to 360), represented by movements that simulate the intraoral insertion and disinsertion of the telescopic systems. The present study highlights that the telescopic systems in which the primary crown is made of zirconia ceramics presents more advantages than those made of Co–Cr. All telescopic systems studied, highlighted that by modifying the taper angle from 0° to 2°, the retention forces have decreased, irrespective of the materials used for the fabrication of the primary crown, suggesting that by using a taper angle of 0°, which is known to be ideal, more efficient, and reliable prosthesis can be developed. Thus, even though the ceramic–metallic telescopic system exhibited the highest retention, all telescopic crowns evaluated registered values between 2–7 N, indicating that they are suitable for clinical use. Full article
(This article belongs to the Special Issue Dental Biomaterials 2020)
Show Figures

Graphical abstract

13 pages, 3203 KB  
Article
Retention Force of Removable Partial Dentures with CAD-CAM-Fabricated Telescopic Crowns
by Christin Arnold, Ramona Schweyen, Arne Boeckler and Jeremias Hey
Materials 2020, 13(14), 3228; https://doi.org/10.3390/ma13143228 - 20 Jul 2020
Cited by 13 | Viewed by 5474
Abstract
The aim of this study was to compare the retention forces after artificial aging of telescopic crowns fabricated either by a conventional lost-wax technique or by computer-aided design/computer-aided manufacturing (CAD-CAM) technology. Two types of telescopic crowns (0°) were fabricated conventionally using high-noble (group [...] Read more.
The aim of this study was to compare the retention forces after artificial aging of telescopic crowns fabricated either by a conventional lost-wax technique or by computer-aided design/computer-aided manufacturing (CAD-CAM) technology. Two types of telescopic crowns (0°) were fabricated conventionally using high-noble (group A) and non-precious metal (group B). CAD-CAM fabricated telescopic crowns (0°) were made of non-precious metal (group C). Retention forces were assessed before and after artificial aging and after axial and non-axial loading. Initially [I.] and after artificial aging [IV.], specimens of group C (I. 16.2 N; IV. 13.6 N) exhibited the highest retention forces. The retention forces in groups B (I. 12.5 N; IV. 4.6 N) and A (I. 9.6 N; IV. 2.9 N) were found to be lower than those of group C. The retention force differences between the groups were statistically significant (p < 0.001) at all measurement times [I. vs. IV.]. Different fabricated telescopic crowns with approximately identical designs and materials exhibited different retention forces and different long-term retentive behavior. An optimized CAD-CAM process with individually defined design parameters ensured telescopic crowns with a better fit. These findings might influence prospective clinical decision-making. Full article
Show Figures

Figure 1

Back to TopTop