Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (11)

Search Parameters:
Keywords = synthetic contrast-enhanced MRI modeling

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
23 pages, 5892 KB  
Article
Deep Learning-Based Synthetic Contrast-Enhanced Breast MRI for Monitoring Response to Neoadjuvant Therapy
by Suleeporn Sujichantararat, Debosmita Biswas, Anum S. Kazerouni, Edric D. Tsang, Aditi Sathe, Daniel S. Hippe, Vivian Y. Park, Maggie Chung, Jennifer M. Specht, Suzanne M. Dintzis, Habib Rahbar, James H. Holmes, Wei Huang and Savannah C. Partridge
Cancers 2026, 18(11), 1835; https://doi.org/10.3390/cancers18111835 - 4 Jun 2026
Viewed by 771
Abstract
Background/Objectives: Contrast-enhanced (CE) breast MRI is highly sensitive for evaluating breast cancer extent and response to neoadjuvant therapy (NAT) but requires intravenous administration of gadolinium-based contrast agents (GBCA), increasing cost, time, patient discomfort, and health concerns. This study explored the feasibility of [...] Read more.
Background/Objectives: Contrast-enhanced (CE) breast MRI is highly sensitive for evaluating breast cancer extent and response to neoadjuvant therapy (NAT) but requires intravenous administration of gadolinium-based contrast agents (GBCA), increasing cost, time, patient discomfort, and health concerns. This study explored the feasibility of reducing GBCA use in treatment monitoring using a deep learning (DL) model to synthesize CE-MRI from non-contrast MRI. Methods: This IRB-approved retrospective pilot study evaluated women with breast cancer enrolled in an ongoing trial using serial MRI to monitor NAT prior to surgery. A pre-trained DL model was used to synthesize CE-MRI from T1-, T2-, and diffusion-weighted MRI. Changes in tumor volume at early (post-1-cycle NAT) and mid-treatment were measured on synthetic and acquired CE-MRI. Performance for predicting residual cancer burden (RCB) class 0/1 was evaluated using AUC and compared with DeLong’s test. Results: 27 women were included in the study (median age, 47 years [range = 28–75]); 14 (52%) achieved RCB class 0 and six (22%) achieved class 1. Synthetic CE-MRI-derived tumor volumes showed strong correlation with those from acquired CE-MRI at pre-treatment (ρ = 0.92, p < 0.001) and early treatment (ρ = 0.83, p < 0.001), but lower agreement at mid-treatment (ρ = 0.57, p = 0.002). Change in tumor volume on synthetic CE-MRI was numerically similar to acquired CE-MRI for predicting RCB class 0/1 vs. 2/3 at both early (AUC = 0.84 vs. 0.86, p = 0.83) and mid-treatment (AUC = 0.73 vs. 0.75, p = 0.80). Conclusions: Synthetic CE-MRI demonstrates preliminary feasibility as a non-contrast surrogate for predicting favorable outcomes (RCB class 0/1) in this pilot study, but inconsistencies in tumor volume measurement vs. acquired CE-MRI warrant further model refinement and validation. Full article
Show Figures

Figure 1

28 pages, 5701 KB  
Article
Multi-Sequence Guided Generation of Contrast-Enhanced Magnetic Resonance Imaging Using Diffusion Models
by Yue Xu, Xiaokun Zhou, Wei Jiang, Chuanbing Wang, Xiangnan Geng, Da Cao, Wujin Xiao, Bin Liu and Wei Wang
Bioengineering 2026, 13(6), 634; https://doi.org/10.3390/bioengineering13060634 - 28 May 2026
Viewed by 371
Abstract
Objectives: Contrast-enhanced magnetic resonance imaging (CE-MRI) plays an important role in the diagnosis, treatment monitoring, and follow-up of brain tumors. However, the use of gadolinium-based contrast agents (GBCAs) is limited in patients with contraindications, such as severe renal impairment or situations requiring [...] Read more.
Objectives: Contrast-enhanced magnetic resonance imaging (CE-MRI) plays an important role in the diagnosis, treatment monitoring, and follow-up of brain tumors. However, the use of gadolinium-based contrast agents (GBCAs) is limited in patients with contraindications, such as severe renal impairment or situations requiring repeated examinations. This study aimed to develop a diffusion model-based Difference-Aware Guided Control Network (DAGCN) for synthesizing high-quality contrast-enhanced T1-weighted MRI (T1-CE) from non-contrast T1-weighted images in combination with an auxiliary sequence. Methods: Using the BraTS 2021 dataset, we proposed a two-stage generative framework that first localizes lesion-related enhancement cues and then guides image synthesis. In the first stage, a Difference-Aware Fusion and Prediction (DAFP) module was designed to extract complementary information from non-contrast T1-weighted images and an auxiliary sequence (T2-weighted or FLAIR) through dual-branch feature extraction and cross-modal channel attention fusion, followed by prediction of a lesion-related discrepancy map. In the second stage, the predicted discrepancy map was concatenated with the original T1-weighted images and introduced into a ControlNet-guided diffusion model to constrain the reverse denoising process and generate the target T1-CE image. Model performance was evaluated by visual comparison, quantitative metrics including peak signal-to-noise ratio (PSNR), structural similarity index measure (SSIM), visual information fidelity (VIF), and normalized cross-correlation (NCC), as well as blinded radiologist scoring of image quality (IQ), clinical replaceability (IC), contrast enhancement (CE), and lesion conformity (CF). Results: DAGCN generated synthetic T1-CE images with preserved global anatomical structure and faithful local lesion enhancement without the need for contrast agent administration. Compared with baseline methods, DAGCN achieved the highest PSNR and NCC under both T1 + T2 and T1 + FLAIR settings, while showing competitive SSIM and VIF performance. Visual comparison and radiologist-based subjective evaluation further indicated improved lesion-focused enhancement fidelity and reduced false-positive enhancement. Among the two auxiliary sequence settings, the T1 + FLAIR configuration provided more specific lesion localization and cleaner background suppression than the T1 + T2 configuration, particularly by reducing interference from cerebrospinal fluid signals. Conclusions: The proposed DAGCN framework enables the synthesis of clinically informative contrast-enhanced-like MRI from non-contrast multi-sequence inputs and may provide a promising alternative for patients in whom gadolinium administration is contraindicated or should be avoided. In particular, the FLAIR-guided setting showed advantages in lesion specificity, background cleanliness, and overall diagnostic quality. Full article
Show Figures

Figure 1

14 pages, 1620 KB  
Article
Excellent Reproducibility of Synthetic Extracellular Volume Without Blood Extraction Across Different Cardiomyopathies Using Published Regression Models
by Jeong W. Choi, Sylvia Biso, Jonathan Weber, Karli Pipitone, Shibu Philip and Omar K. Khalique
J. Cardiovasc. Dev. Dis. 2026, 13(1), 34; https://doi.org/10.3390/jcdd13010034 - 7 Jan 2026
Cited by 1 | Viewed by 745
Abstract
T1 mapping and extracellular volume (ECV) calculations in cardiac magnetic resonance (CMR) have the potential to identify early fibrosis that is not yet visible using late gadolinium enhancement; however, the need for same-day blood draws due to the temporal variations in hematocrit (Hct) [...] Read more.
T1 mapping and extracellular volume (ECV) calculations in cardiac magnetic resonance (CMR) have the potential to identify early fibrosis that is not yet visible using late gadolinium enhancement; however, the need for same-day blood draws due to the temporal variations in hematocrit (Hct) limits the use of ECV. We aimed to determine the reproducibility of synthetic Hct and ECV using different published models among groups of subjects. Healthy subjects and those with diagnosed cardiac amyloidosis, sarcoidosis, and hypertrophic cardiomyopathy (HCM) scanned using a 1.5T scanner with native and post-contrast T1 maps and same-day Hct were included. Among 148 subjects, there was excellent reproducibility (all ICCs ~0.98) between synthetic and measured ECV across the six formulas, despite only modest reproducibility of synthetic/measured Hct (ICCs 0.52–0.66). The levels of accuracy predicting abnormal measured ECV were consistently excellent among the different synthetic ECV models. The difference in the CMR vendor used to generate models did not seem to affect the results of the comparisons. We conclude that synthetic ECV yielded excellent reproducibility compared with ECV calculated using measured hematocrit, possibly obviating the need for blood extraction in cardiac MRI settings without point-of-care Hct. Full article
(This article belongs to the Section Imaging)
Show Figures

Figure 1

21 pages, 2336 KB  
Article
Machine and Deep Learning on Radiomic Features from Contrast-Enhanced Mammography and Dynamic Contrast-Enhanced Magnetic Resonance Imaging for Breast Cancer Characterization
by Roberta Fusco, Vincenza Granata, Teresa Petrosino, Paolo Vallone, Maria Assunta Daniela Iasevoli, Mauro Mattace Raso, Sergio Venanzio Setola, Davide Pupo, Gerardo Ferrara, Annarita Fanizzi, Raffaella Massafra, Miria Lafranceschina, Daniele La Forgia, Laura Greco, Francesca Romana Ferranti, Valeria De Soccio, Antonello Vidiri, Francesca Botta, Valeria Dominelli, Enrico Cassano, Charlotte Marguerite Lucille Trombadori, Paolo Belli, Giovanna Trecate, Chiara Tenconi, Maria Carmen De Santis, Luca Boldrini and Antonella Petrilloadd Show full author list remove Hide full author list
Bioengineering 2025, 12(9), 952; https://doi.org/10.3390/bioengineering12090952 - 2 Sep 2025
Cited by 5 | Viewed by 2632
Abstract
Objective: The aim of this study was to evaluate the accuracy of machine and deep learning approaches on radiomics features obtained by Dynamic Contrast Enhanced Magnetic Resonance Imaging (DCE-MRI) and contrast enhanced mammography (CEM) in the characterization of breast cancer and in the [...] Read more.
Objective: The aim of this study was to evaluate the accuracy of machine and deep learning approaches on radiomics features obtained by Dynamic Contrast Enhanced Magnetic Resonance Imaging (DCE-MRI) and contrast enhanced mammography (CEM) in the characterization of breast cancer and in the prediction of the tumor molecular profile. Methods: A total of 153 patients with malignant and benign lesions were analyzed and underwent MRI examinations. Considering the histological findings as the ground truth, three different types of findings were used in the analysis: (1) benign versus malignant lesions; (2) G1 + G2 vs. G3 classification; (3) the presence of human epidermal growth factor receptor 2 (HER2+ vs. HER2−). Radiomic features (n = 851) were extracted from manually segmented regions of interest using the PyRadiomics platform, following IBSI-compliant protocols. Highly correlated features were excluded, and the remaining features were standardized using z-score normalization. A feature selection process based on Elastic Net regularization (α = 0.5) was used to reduce dimensionality. Synthetic balancing of the training data was applied using the ROSE method to address class imbalance. Model performance was evaluated using repeated 10-fold cross-validation and AUC-based metrics. Results: Among the 153 patients enrolled in the studies, 113 were malignant lesions. Among the 113 malignant lesions, 32 had high grading (G3) and 66 had the HER2+ receptor. Radiomic features derived from both CEM and DCE-MRI showed strong discriminative performance for malignancy detection, with several features achieving AUCs above 0.80. Gradient Boosting Machine (GBM) achieved the highest accuracy (0.911) and AUC (0.907) in differentiating benign from malignant lesions. For tumor grading, the neural network model attained the best accuracy (0.848), while LASSO yielded the highest sensitivity (0.667) for detecting high-grade tumors. In predicting HER2+ status, the neural network also performed best (AUC = 0.669), with a sensitivity of 0.842. Conclusions: Radiomics-based machine learning models applied to multiparametric CEM and DCE-MRI images offer promising, non-invasive tools for breast cancer characterization. The models effectively distinguished benign from malignant lesions and showed potential in predicting histological grade and HER2 status. These results demonstrate that radiomic features extracted from CEM and DCE-MRI, when analyzed through machine and deep learning models, can support accurate breast cancer characterization. Such models may assist clinicians in early diagnosis, histological grading, and biomarker assessment, potentially enhancing personalized treatment planning and non-invasive decision-making in routine practice. Full article
Show Figures

Figure 1

22 pages, 4943 KB  
Article
Towards MR-Only Radiotherapy in Head and Neck: Generation of Synthetic CT from Zero-TE MRI Using Deep Learning
by Souha Aouadi, Mojtaba Barzegar, Alla Al-Sabahi, Tarraf Torfeh, Satheesh Paloor, Mohamed Riyas, Palmira Caparrotti, Rabih Hammoud and Noora Al-Hammadi
Information 2025, 16(6), 477; https://doi.org/10.3390/info16060477 - 6 Jun 2025
Cited by 2 | Viewed by 4649
Abstract
This study investigates the generation of synthetic CT (sCT) images from zero echo time (ZTE) MRI to support MR-only radiotherapy, which can reduce image registration errors and lower treatment planning costs. Since MRI lacks the electron density data required for accurate dose calculations, [...] Read more.
This study investigates the generation of synthetic CT (sCT) images from zero echo time (ZTE) MRI to support MR-only radiotherapy, which can reduce image registration errors and lower treatment planning costs. Since MRI lacks the electron density data required for accurate dose calculations, generating reliable sCTs is essential. ZTE MRI, offering high bone contrast, was used with two deep learning models: attention deep residual U-Net (ADR-Unet) and derived conditional generative adversarial network (cGAN). Data from 17 head and neck cancer patients were used to train and evaluate the models. ADR-Unet was enhanced with deep residual blocks and attention mechanisms to improve learning and reconstruction quality. Both models were implemented in-house and compared to standard U-Net and Unet++ architectures using image quality metrics, visual inspection, and dosimetric analysis. Volumetric modulated arc therapy (VMAT) planning was performed on both planning CT and generated sCTs. ADR-Unet achieved a mean absolute error of 55.49 HU and a Dice score of 0.86 for bone structures. All the models demonstrated Gamma pass rates above 99.4% and dose deviations within 2–3%, confirming clinical acceptability. These results highlight ADR-Unet and cGAN as promising solutions for accurate sCT generation, enabling effective MR-only radiotherapy. Full article
Show Figures

Figure 1

20 pages, 6501 KB  
Article
A Deep Learning-Based Framework for Highly Accelerated Prostate MR Dispersion Imaging
by Kai Zhao, Kaifeng Pang, Alex LingYu Hung, Haoxin Zheng, Ran Yan and Kyunghyun Sung
Cancers 2024, 16(17), 2983; https://doi.org/10.3390/cancers16172983 - 27 Aug 2024
Cited by 3 | Viewed by 2415
Abstract
Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) measures microvascular perfusion by capturing the temporal changes of an MRI contrast agent in a target tissue, and it provides valuable information for the diagnosis and prognosis of a wide range of tumors. Quantitative DCE-MRI analysis commonly [...] Read more.
Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) measures microvascular perfusion by capturing the temporal changes of an MRI contrast agent in a target tissue, and it provides valuable information for the diagnosis and prognosis of a wide range of tumors. Quantitative DCE-MRI analysis commonly relies on the nonlinear least square (NLLS) fitting of a pharmacokinetic (PK) model to concentration curves. However, the voxel-wise application of such nonlinear curve fitting is highly time-consuming. The arterial input function (AIF) needs to be utilized in quantitative DCE-MRI analysis. and in practice, a population-based arterial AIF is often used in PK modeling. The contribution of intravascular dispersion to the measured signal enhancement is assumed to be negligible. The MR dispersion imaging (MRDI) model was recently proposed to account for intravascular dispersion, enabling more accurate PK modeling. However, the complexity of the MRDI hinders its practical usability and makes quantitative PK modeling even more time-consuming. In this paper, we propose fast MR dispersion imaging (fMRDI) to effectively represent the intravascular dispersion and highly accelerated PK parameter estimation. We also propose a deep learning-based, two-stage framework to accelerate PK parameter estimation. We used a deep neural network (NN) to estimate PK parameters directly from enhancement curves. The estimation from NN was further refined using several steps of NLLS, which is significantly faster than performing NLLS from random initializations. A data synthesis module is proposed to generate synthetic training data for the NN. Two data-processing modules were introduced to improve the model’s stability against noise and variations. Experiments on our in-house clinical prostate MRI dataset demonstrated that our method significantly reduces the processing time, produces a better distinction between normal and clinically significant prostate cancer (csPCa) lesions, and is more robust against noise than conventional DCE-MRI analysis methods. Full article
(This article belongs to the Special Issue MRI in Prostate Cancer)
Show Figures

Figure 1

15 pages, 2594 KB  
Article
Automatic Myocardium Segmentation in Delayed-Enhancement MRI with Pathology-Specific Data Augmentation and Deep Learning Architectures
by Gonzalo E. Mosquera-Rojas, Cylia Ouadah, Azadeh Hadadi, Alain Lalande and Sarah Leclerc
Algorithms 2023, 16(10), 488; https://doi.org/10.3390/a16100488 - 20 Oct 2023
Cited by 7 | Viewed by 3308
Abstract
The extent of myocardial infarction (MI) can be evaluated thanks to delayed enhancement (DE) cardiac MRI. DE MRI is an imaging technique acquired several minutes after the injection of a contrast agent where MI appears with a bright signal. The automatic myocardium segmentation [...] Read more.
The extent of myocardial infarction (MI) can be evaluated thanks to delayed enhancement (DE) cardiac MRI. DE MRI is an imaging technique acquired several minutes after the injection of a contrast agent where MI appears with a bright signal. The automatic myocardium segmentation in DE MRI is quite challenging, especially when MI is present, since these areas usually showcase a heterogeneous aspect in terms of shape and intensity, thus obstructing the myocardium visibility. To overcome this issue, we propose an image processing-based data augmentation algorithm where diverse synthetic cases of MI were created in two different ways: fixed and adaptive. In the first one, the training set is enlarged by a specific factor, whereas in the second, the method receives feedback from the segmentation model during training and performs the augmentation exclusively on complex cases. The method performance was evaluated in single and multi-modality settings. In this latter, information from kinetic images (Cine MRI), which are acquired along DE MRI in the same examination, is also used, and the extracted features from both modalities are fused. The results show that applying the data augmentation in a fixed fashion on a multi-modality setting leads to a more consistent segmentation of the myocardium in DE MRI. The segmentation models, which were all UNet-based architectures, can better relate MI areas with the myocardium, thus increasing its overall robustness to pathology-specific local pattern perturbations. Full article
(This article belongs to the Special Issue Artificial Intelligence for Medical Imaging)
Show Figures

Figure 1

26 pages, 5061 KB  
Article
Synthetic Inflammation Imaging with PatchGAN Deep Learning Networks
by Aniket A. Tolpadi, Johanna Luitjens, Felix G. Gassert, Xiaojuan Li, Thomas M. Link, Sharmila Majumdar and Valentina Pedoia
Bioengineering 2023, 10(5), 516; https://doi.org/10.3390/bioengineering10050516 - 25 Apr 2023
Cited by 8 | Viewed by 3928
Abstract
Background: Gadolinium (Gd)-enhanced Magnetic Resonance Imaging (MRI) is crucial in several applications, including oncology, cardiac imaging, and musculoskeletal inflammatory imaging. One use case is rheumatoid arthritis (RA), a widespread autoimmune condition for which Gd MRI is crucial in imaging synovial joint inflammation, [...] Read more.
Background: Gadolinium (Gd)-enhanced Magnetic Resonance Imaging (MRI) is crucial in several applications, including oncology, cardiac imaging, and musculoskeletal inflammatory imaging. One use case is rheumatoid arthritis (RA), a widespread autoimmune condition for which Gd MRI is crucial in imaging synovial joint inflammation, but Gd administration has well-documented safety concerns. As such, algorithms that could synthetically generate post-contrast peripheral joint MR images from non-contrast MR sequences would have immense clinical utility. Moreover, while such algorithms have been investigated for other anatomies, they are largely unexplored for musculoskeletal applications such as RA, and efforts to understand trained models and improve trust in their predictions have been limited in medical imaging. Methods: A dataset of 27 RA patients was used to train algorithms that synthetically generated post-Gd IDEAL wrist coronal T1-weighted scans from pre-contrast scans. UNets and PatchGANs were trained, leveraging an anomaly-weighted L1 loss and global generative adversarial network (GAN) loss for the PatchGAN. Occlusion and uncertainty maps were also generated to understand model performance. Results: UNet synthetic post-contrast images exhibited stronger normalized root mean square error (nRMSE) than PatchGAN in full volumes and the wrist, but PatchGAN outperformed UNet in synovial joints (UNet nRMSEs: volume = 6.29 ± 0.88, wrist = 4.36 ± 0.60, synovial = 26.18 ± 7.45; PatchGAN nRMSEs: volume = 6.72 ± 0.81, wrist = 6.07 ± 1.22, synovial = 23.14 ± 7.37; n = 7). Occlusion maps showed that synovial joints made substantial contributions to PatchGAN and UNet predictions, while uncertainty maps showed that PatchGAN predictions were more confident within those joints. Conclusions: Both pipelines showed promising performance in synthesizing post-contrast images, but PatchGAN performance was stronger and more confident within synovial joints, where an algorithm like this would have maximal clinical utility. Image synthesis approaches are therefore promising for RA and synthetic inflammatory imaging. Full article
(This article belongs to the Special Issue AI in MRI: Frontiers and Applications)
Show Figures

Graphical abstract

21 pages, 3266 KB  
Article
Glu-Urea-Lys Scaffold Functionalized Superparamagnetic Iron Oxide Nanoparticles Targeting PSMA for In Vivo Molecular MRI of Prostate Cancer
by Wei Zhou, Jiandong Huang, Qingwei Xiao, Shunmin Hu, Shijia Li, Jie Zheng, Zhiyun Du, Jiangling Peng and Huixiong Chen
Pharmaceutics 2022, 14(10), 2051; https://doi.org/10.3390/pharmaceutics14102051 - 26 Sep 2022
Cited by 9 | Viewed by 4025
Abstract
The prostate specific membrane antigen (PSMA), extensively overexpressed on prostate cancer (PCa) cell surface, has been validated as a diagnostic biomarker for PCa. However, insufficient attention has been paid to the development of PSMA-specific probes loaded with small chemical molecules for the in [...] Read more.
The prostate specific membrane antigen (PSMA), extensively overexpressed on prostate cancer (PCa) cell surface, has been validated as a diagnostic biomarker for PCa. However, insufficient attention has been paid to the development of PSMA-specific probes loaded with small chemical molecules for the in vivo molecular imaging of PCa. In this study, we innovatively labelled superparamagnetic iron oxide nanoparticles with a PSMA-targeting Glu-Urea-Lys scaffold. An optimized synthetic route was developed to offer a physiochemically stable probe. The probe demonstrated high binding affinity (0.38 ± 0.08 μg(Fe)/mL) and binding specificity to PSMA expressed on prostate cancer cell surface in vitro. In a xenograft PCa mouse model, significant negative contrast of the implanted prostate cancer xenograft could be specifically observed by MRI 6 h after tail vein injection of the tracer (Fe, 20 mg/kg), exhibiting its potential to exclusively enhance magnetic resonance detection of PCa. Full article
(This article belongs to the Special Issue Nanoparticle-Mediated Diagnosis and Treatment of Human Disease)
Show Figures

Figure 1

17 pages, 6239 KB  
Article
Magnetic Resonance-Based Synthetic Computed Tomography Using Generative Adversarial Networks for Intracranial Tumor Radiotherapy Treatment Planning
by Chun-Chieh Wang, Pei-Huan Wu, Gigin Lin, Yen-Ling Huang, Yu-Chun Lin, Yi-Peng (Eve) Chang and Jun-Cheng Weng
J. Pers. Med. 2022, 12(3), 361; https://doi.org/10.3390/jpm12030361 - 26 Feb 2022
Cited by 16 | Viewed by 4062
Abstract
The purpose of this work is to develop a reliable deep-learning-based method that is capable of synthesizing needed CT from MRI for radiotherapy treatment planning. Simultaneously, we try to enhance the resolution of synthetic CT. We adopted pix2pix with a 3D framework, which [...] Read more.
The purpose of this work is to develop a reliable deep-learning-based method that is capable of synthesizing needed CT from MRI for radiotherapy treatment planning. Simultaneously, we try to enhance the resolution of synthetic CT. We adopted pix2pix with a 3D framework, which is a conditional generative adversarial network, to map the MRI data domain into the CT data domain of our dataset. The original dataset contains paired MRI and CT images of 31 subjects; 26 pairs were used for model training and 5 were used for model validation. To identify the correctness of the synthetic CT of models, all of the synthetic CTs were calculated by the quantized image similarity formulas: cosine angle distance, Euclidean distance, mean square error, peak signal-to-noise ratio, and mean structural similarity. Two radiologists independently evaluated the satisfaction score, including spatial, detail, contrast, noise, and artifacts, for each imaging attribute. The mean (±standard deviation) of the structural similarity indices (CAD, L2 norm, MSE, PSNR, and MSSIM) between five real CT scans and the synthetic CT scans were 0.96 ± 0.015, 76.83 ± 12.06, 0.00118 ± 0.00037, 29.47 ± 1.35, and 0.84 ± 0.036, respectively. For synthetic CT, radiologists rated the results as evincing excellent satisfaction in spatial geometry and noise level, good satisfaction in contrast and artifacts, and fair imaging details. The similarity index and clinical evaluation results between synthetic CT and original CT guarantee the usability of the proposed method. Full article
Show Figures

Figure 1

11 pages, 1029 KB  
Article
External Validation of a Radiomics Model for the Prediction of Complete Response to Neoadjuvant Chemoradiotherapy in Rectal Cancer
by Anaïs Bordron, Emmanuel Rio, Bogdan Badic, Omar Miranda, Olivier Pradier, Mathieu Hatt, Dimitris Visvikis, François Lucia, Ulrike Schick and Vincent Bourbonne
Cancers 2022, 14(4), 1079; https://doi.org/10.3390/cancers14041079 - 21 Feb 2022
Cited by 26 | Viewed by 4088
Abstract
Objective: Our objective was to develop a radiomics model based on magnetic resonance imaging (MRI) and contrast-enhanced computed tomography (CE-CT) to predict pathological complete response (pCR) to neoadjuvant treatment in locally advanced rectal cancer (LARC). Material: All patients treated for a LARC [...] Read more.
Objective: Our objective was to develop a radiomics model based on magnetic resonance imaging (MRI) and contrast-enhanced computed tomography (CE-CT) to predict pathological complete response (pCR) to neoadjuvant treatment in locally advanced rectal cancer (LARC). Material: All patients treated for a LARC with neoadjuvant CRT and subsequent surgery in two separate institutions between 2012 and 2019 were considered. Both pre-CRT pelvic MRI and CE-CT were mandatory for inclusion. The tumor was manually segmented on the T2-weighted and diffusion axial MRI sequences and on CE-CT. In total, 88 radiomic parameters were extracted from each sequence using the Miras© software, with a total of 822 features by patient. The cohort was split into training (Institution 1) and testing (Institution 2) sets. The ComBat and Synthetic Minority Over-sampling Technique (SMOTE) approaches were used to account for inter-institution heterogeneity and imbalanced data, respectively. We selected the most predictive characteristics using Spearman’s rank correlation and the Area Under the ROC Curve (AUC). Five pCR prediction models (clinical, radiomics before and after ComBat, and combined before and after ComBat) were then developed on the training set with a neural network approach and a bootstrap internal validation (n = 1000 replications). A cut-off maximizing the model’s performance was defined on the training set. Each model was then evaluated on the testing set using sensitivity, specificity, balanced accuracy (Bacc) with the predefined cut-off. Results: Out of the 124 included patients, 14 had pCR (11.3%). After ComBat harmonization, the radiomic and the combined models obtained a Bacc of 68.2% and 85.5%, respectively, while the clinical model and the pre-ComBat combined achieved respective Baccs of 60.0% and 75.5%. Conclusions: After correction of inter-site variability and imbalanced data, addition of radiomic features enhances the prediction of pCR after neoadjuvant CRT in LARC. Full article
Show Figures

Figure 1

Back to TopTop