16 pages, 6084 KiB  
Article
First Design of a Contact Lens for Diagnosis of Dehydration
by Kundan Sivashanmugan, Reece E. Albert and Joseph R. Lakowicz
Biosensors 2025, 15(8), 532; https://doi.org/10.3390/bios15080532 - 14 Aug 2025
Viewed by 266
Abstract
Dehydration is a serious medical problem for elderly patients and young children. The most widely used diagnostics are measurements of sodium ion (Na+) and potassium ion (K+) in blood serum. Dehydration is difficult to diagnose even by trained health [...] Read more.
Dehydration is a serious medical problem for elderly patients and young children. The most widely used diagnostics are measurements of sodium ion (Na+) and potassium ion (K+) in blood serum. Dehydration is difficult to diagnose even by trained health care professionals because the body compensates to maintain the appearance of skin. These measurements required a blood draw because specific tests are generally not available for only Na+ and K+. The blood samples are analyzed by an electrolyte panel (EP) or a basic metabolic panel (BMP). Most hospitals limit EP and BMP to one per day to control costs. More frequent measurements of Na+ and K+ are needed, especially during rehydration. We designed a dehydration contact lens that can provide the Na+ and K+ concentrations as needed or for continuous monitoring. The measurements are obtained from the fluorescent lifetime or wavelength-ratiometric intensities of the Na+- and K+-sensitive fluorophores. The dehydration contact lens does not contain electronic components and are inexpensive to prepare. Full article
(This article belongs to the Special Issue Advanced Fluorescence Biosensors)
Show Figures

Graphical abstract

16 pages, 3297 KiB  
Article
On the Possibility of Fluorescent Capture Immunoassays on a Contact Lens
by Kundan Sivashanmugan, E. Albert Reece and Joseph R. Lakowicz
Biosensors 2025, 15(5), 326; https://doi.org/10.3390/bios15050326 - 20 May 2025
Viewed by 640
Abstract
Blood samples and testing are routine in healthcare. Presently, there is a growing interest in using tear samples in place of blood. Tear samples can be obtained non-invasively and collection does not require the skills of a trained phlebotomist. Red blood cells and [...] Read more.
Blood samples and testing are routine in healthcare. Presently, there is a growing interest in using tear samples in place of blood. Tear samples can be obtained non-invasively and collection does not require the skills of a trained phlebotomist. Red blood cells and other cells are not present in tears, which avoids centrifugation. Importantly, basal tear samples contain most of the biomarkers present in blood. The difficulty is the small volume of basal tears, which is about 7 μL in each eye. Any contact with the eye results in additional reflex tears with a different chemical composition. The small tear samples are collected with capillary tubes and then sent out for amplified assays, such as enzyme-linked immunosorbent assay (ELISA) or polymerase chain reaction (PCR). The results are not available for several days or a week and, therefore, are less useful in an ophthalmology office. We propose the use of a contact lens that contains bound antibodies for fluorescence immunoassays. The lenses could be removed from the patient for point-of-care measurements at the bedside. To prove that this concept is possible, we performed a three-layer protein capture assay that mimics an immunoassay. For convenience, we used lysozyme (Lys), which spontaneously coats silicon hydrogel (SiHG) contact lenses (CL). Anti-lysozyme IgG was the second layer captured, with anti-lysozyme considered to be the target biomarker. The third layer was rhodamine or Alexa Fluor-labeled Ab against the IgG Fc region, considered to be the detection antibody. The multiple protein layers were stable and did not wash off the SiHG lenses. These results strongly suggest the contact lens can be used for capture immunoassays for a wide variety of biomarkers. Full article
Show Figures

Graphical abstract

11 pages, 2946 KiB  
Article
Intraocular Pressure Damping by Corneal Elasticity and Viscosity Modulation Using Silicone Hydrogel Soft Contact Lenses
by Francisco J. Ávila
Optics 2025, 6(2), 18; https://doi.org/10.3390/opt6020018 - 9 May 2025
Viewed by 762
Abstract
The biomechanical and optical properties of the cornea are responsible for its functional response, structural integrity and refractive function. Corneal viscoelasticity is the cornea’s ability to absorb transient increases in intraocular pressure (IOP) and constitutes a biomarker of glaucoma. The use of silicone [...] Read more.
The biomechanical and optical properties of the cornea are responsible for its functional response, structural integrity and refractive function. Corneal viscoelasticity is the cornea’s ability to absorb transient increases in intraocular pressure (IOP) and constitutes a biomarker of glaucoma. The use of silicone hydrogel soft contact lenses (SiH-SCLs) can affect both corneal viscoelasticity and IOP. However, the behavior of the pure elastic and viscous components remains hidden within viscoelastic properties, and their influence and relationship with IOP in the biomechanical changes observed with short-term SiH-SCL use remains unknown. This study investigates the effects of silicone hydrogel soft contact lenses (SiH-SCLs) on corneal elasticity and viscosity and their influence on IOP over different lens wear periods: 10 or 20 consecutive days. Ocular Response Analyzer (ORA) measurements were combined with a biomechanical Standard Linear Solid Model (SLSM) to differentiate and calculate the elastic and viscous components of the cornea. The results showed that after 10 days of lens wear, elasticity and viscosity increased, with a significant reduction in IOP. After 20 days, elasticity and viscosity decreased, with a further reduction in IOP, reflecting a time-dependent effect of SiH-SCLs on corneal biomechanics. The study indicates the potential protective role of corneal viscosity against changes in IOP, which may be used for glaucoma treatment. Full article
(This article belongs to the Section Biomedical Optics)
Show Figures

Figure 1

14 pages, 2108 KiB  
Article
Tear Film Changes and Ocular Symptoms Associated with Soft Contact Lens Wear
by Eduardo Insua Pereira, Madalena Lira and Ana Paula Sampaio
Vision 2025, 9(2), 27; https://doi.org/10.3390/vision9020027 - 1 Apr 2025
Viewed by 1055
Abstract
Discomfort is one of the leading causes associated with contact lens dropout. This study investigated changes in the tear film parameters induced by lens wear and their relationship with ocular symptomology. Thirty-four lens wearers (32.9 ± 9.1 years, 7 men) and thirty-three non-lens [...] Read more.
Discomfort is one of the leading causes associated with contact lens dropout. This study investigated changes in the tear film parameters induced by lens wear and their relationship with ocular symptomology. Thirty-four lens wearers (32.9 ± 9.1 years, 7 men) and thirty-three non-lens wearers (29.4 ± 6.8 years, 12 men) participated in this clinical setting. Subjects were categorised into asymptomatic (n = 11), moderate (n = 15), or severe symptomatic (n = 8). Clinical evaluations were performed in the morning, including blink frequency and completeness, pre-corneal (NIBUT) and pre-lens non-invasive break-up (PL-NIBUT), lipid interference patterns, and tear meniscus height. Contact lens wearers had a higher percentage of incomplete blinks (37% vs. 19%, p < 0.001) and reduced tear meniscus height compared to controls (0.24 ± 0.08 vs. 0.28 ± 0.10 mm, p = 0.014). PL-NIBUT was shorter than NIBUT (7.6 ± 6.2 vs. 10.7 ± 9.3 s. p = 0.002). Significant statistical differences between the groups were found in the PL-NIBUT (p = 0.01) and NIBUT (p = 0.05), with asymptomatic recording higher times than symptomatic. Long-term use of silicone–hydrogel lenses can affect tear stability, production, and adequate distribution through blinking. Ocular symptomology correlates with tear stability parameters in both lens wearers and non-wearers. Full article
Show Figures

Figure 1

18 pages, 3890 KiB  
Article
Polyethylene Glycol Diacrylate Adapted Photopolymerization Material for Contact Lens with Improved Elastic Modulus Properties
by Yamin Chen, Dianyang Li, Yougen Chen and Hui Fang
Materials 2025, 18(4), 827; https://doi.org/10.3390/ma18040827 - 13 Feb 2025
Cited by 1 | Viewed by 1658
Abstract
Four kinds of silicone hydrogel transparent contact lenses (CLs) with different formulations were prepared by the free radical photocuring polymerization. By mixing polyethylene glycol diacrylate (PEGDA) of 1000 Da with ethylene glycol dimethacrylate (EGDMA) and adding other silicone monomers and hydrophilic monomers, the [...] Read more.
Four kinds of silicone hydrogel transparent contact lenses (CLs) with different formulations were prepared by the free radical photocuring polymerization. By mixing polyethylene glycol diacrylate (PEGDA) of 1000 Da with ethylene glycol dimethacrylate (EGDMA) and adding other silicone monomers and hydrophilic monomers, the transparency and flexibility of the material were successfully achieved. By optimizing the weight percentage of each component, the best balance of optical performance can be achieved. The photocuring properties of the materials were characterized by electronic universal test, double-beam UV-visible spectrophotometer, Atomic Force Microscope (AFM), Scanning Electron Microscope (SEM) and Fourier Transform Infrared Spectroscopy (FTIR). The results showed that the addition of higher PEGDA content reduces the elastic modulus, improves curing efficiency, improves equilibrium water content (EWC), and enhances light transmission. Hydrogels containing only high PEGDA but no EGDMA showed similar curing rates, water content, and elastic modulus, but had the worst optical transparency, far inferior to the materials mixed with PEGDA and EGDMA. Additionally, imaging performance of the CLs was further evaluated through simulation analysis using Ansys Zemax OpticStudio2024 software. This research provides a new choice of material consideration to improve the performance and wearing comfort of CLs. Full article
Show Figures

Graphical abstract

9 pages, 19621 KiB  
Article
Analysis of Deposition and Diffusion of Cholesterol in Silicone Hydrogel Contact Lenses Using Confocal Microscopy
by Tomasz Suliński, Natalia Nowak, Jędrzej Szymański and Jacek Pniewski
Vision 2024, 8(3), 55; https://doi.org/10.3390/vision8030055 - 20 Sep 2024
Viewed by 1720
Abstract
In this study, we investigated lipid deposition and diffusion in silicone hydrogel (Si-Hy) contact lenses using confocal microscopy. Different Si-Hy lenses were analyzed to understand the interaction patterns of cholesterol with various lens materials. The results highlight significant differences in the deposition and [...] Read more.
In this study, we investigated lipid deposition and diffusion in silicone hydrogel (Si-Hy) contact lenses using confocal microscopy. Different Si-Hy lenses were analyzed to understand the interaction patterns of cholesterol with various lens materials. The results highlight significant differences in the deposition and diffusion of lipids through the lenses, revealing that some materials, such as comfilcon A, allow lipids to diffuse more freely compared to others, such as samfilcon A, which provides a greater barrier. The study also observed different morphology and movement of lipid agglomerates across the lenses and above it surfaces. These findings contribute to the understanding of lipid–lens interaction, which is important for the development of lenses with improved comfort and functionality. The research highlights the importance of considering lipid interactions in the design and selection of Si-Hy contact lenses to enhance wearer comfort and lens performance. Full article
Show Figures

Figure 1

15 pages, 2581 KiB  
Article
Quantifying the Dynamics of Bacterial Biofilm Formation on the Surface of Soft Contact Lens Materials Using Digital Holographic Tomography to Advance Biofilm Research
by Igor Buzalewicz, Aleksandra Kaczorowska, Wojciech Fijałkowski, Aleksandra Pietrowska, Anna Karolina Matczuk, Halina Podbielska, Alina Wieliczko, Wojciech Witkiewicz and Natalia Jędruchniewicz
Int. J. Mol. Sci. 2024, 25(5), 2653; https://doi.org/10.3390/ijms25052653 - 24 Feb 2024
Cited by 9 | Viewed by 3400
Abstract
The increase in bacterial resistance to antibiotics in recent years demands innovative strategies for the detection and combating of biofilms, which are notoriously resilient. Biofilms, particularly those on contact lenses, can lead to biofilm-related infections (e.g., conjunctivitis and keratitis), posing a significant risk [...] Read more.
The increase in bacterial resistance to antibiotics in recent years demands innovative strategies for the detection and combating of biofilms, which are notoriously resilient. Biofilms, particularly those on contact lenses, can lead to biofilm-related infections (e.g., conjunctivitis and keratitis), posing a significant risk to patients. Non-destructive and non-contact sensing techniques are essential in addressing this threat. Digital holographic tomography emerges as a promising solution. This allows for the 3D reconstruction of the refractive index distribution in biological samples, enabling label-free visualization and the quantitative analysis of biofilms. This tool provides insight into the dynamics of biofilm formation and maturation on the surface of transparent materials. Applying digital holographic tomography for biofilm examination has the potential to advance our ability to combat the antibiotic bacterial resistance crisis. A recent study focused on characterizing biofilm formation and maturation on six soft contact lens materials (three silicone hydrogels, three hydrogels), with a particular emphasis on Staphylococcus epidermis and Pseudomonas aeruginosa, both common culprits in ocular infections. The results revealed species- and time-dependent variations in the refractive indexes and volumes of biofilms, shedding light on cell dynamics, cell death, and contact lens material-related factors. The use of digital holographic tomography enables the quantitative analysis of biofilm dynamics, providing us with a better understanding and characterization of bacterial biofilms. Full article
(This article belongs to the Special Issue Molecular Research of Biofilms in Microbial Infections)
Show Figures

Figure 1

15 pages, 1261 KiB  
Article
Characteristics of Pre-Lens Tear Film Behavior in Eyes Wearing Delefilcon A Silicone Hydrogel Water Gradient Contact Lenses
by Norihiko Yokoi, Yuki Furusawa, Hiroaki Kato, Natsuki Kusada, Chie Sotozono, Petar Eftimov and Georgi As. Georgiev
Diagnostics 2023, 13(24), 3642; https://doi.org/10.3390/diagnostics13243642 - 12 Dec 2023
Cited by 1 | Viewed by 1856
Abstract
The pre-lens tear film (PLTF) over (i) delefilcon A silicone hydrogel water gradient (WG; 33–80% from core to surface) contact lenses (CLs) (SHWG-CLs) and (ii) subjects’ own non-WG soft CLs (SCLs) (SO-SCLs) was studied in 30 eyes of 30 subjects to assess the [...] Read more.
The pre-lens tear film (PLTF) over (i) delefilcon A silicone hydrogel water gradient (WG; 33–80% from core to surface) contact lenses (CLs) (SHWG-CLs) and (ii) subjects’ own non-WG soft CLs (SCLs) (SO-SCLs) was studied in 30 eyes of 30 subjects to assess the hypothesized PLTF stabilization over SHWG-CLs. In both eyes, delefilcon A SHWG-CLs (DAILIES TOTAL1®; Alcon, Fort Worth, TX, USA) or SO-SCLs were worn. After 15 min of wearing each lens, the tear meniscus radius (TMR, mm), lipid-layer interference grade (IG) and spread grade (SG), and non-invasive breakup time (NIBUT, seconds) were evaluated and compared between the SHWG-CLs and the SO-SCLs. The comparison between the SHWG-CL and SO-SCL groups (SHWG-CL and SO-SCL, mean ± SD) revealed that TMRs temporarily decreased and reached a plateau value after 15 min (0.21 ± 0.06; 0.21 ± 0.06) compared to the value prior to CL insertion (0.24 ± 0.08; 0.25 ± 0.08), with no significant difference between the two groups. The NIBUT, IG, and SG values after 15 min of wearing the CLs were (9.7 ± 3.7; 4.7 ± 4.2), (1.0 ± 0.2; 1.8 ± 1.0), and (1.1 ± 0.4; 1.9 ± 1.5), respectively, and all values were significantly better in the SHWG-CL group (p < 0.0001, p = 0.0039, and p < 0.0001, respectively). We found that compared to the SO-SCLs, the maintenance of the PLTF on the SHWG-CLs was supported by the thicker and more stable PLTF. Full article
(This article belongs to the Special Issue Diagnosis, Treatment and Management of Eye Diseases)
Show Figures

Figure 1

12 pages, 1763 KiB  
Article
Evaluation of Celligent® Biomimetic Water Gradient Contact Lens Effects on Ocular Surface and Subjective Symptoms
by Raúl Capote-Puente, José-María Sánchez-González, María Carmen Sánchez-González and María-José Bautista-Llamas
Diagnostics 2023, 13(7), 1258; https://doi.org/10.3390/diagnostics13071258 - 27 Mar 2023
Cited by 9 | Viewed by 2500
Abstract
This study aimed to evaluate the non-invasive and subjective symptoms associated with Lehfilcon A water gradient silicone hydrogel contact lenses with bacterial and lipid resistance technology. A prospective, longitudinal, single-centre, self-controlled study was conducted among silicone hydrogel contact lens wearers. Non-invasive analysis of [...] Read more.
This study aimed to evaluate the non-invasive and subjective symptoms associated with Lehfilcon A water gradient silicone hydrogel contact lenses with bacterial and lipid resistance technology. A prospective, longitudinal, single-centre, self-controlled study was conducted among silicone hydrogel contact lens wearers. Non-invasive analysis of the pre-lens tear film was performed using the Integrated Clinical Platform (ICP) Ocular Surface Analyzer (OSA), and the meibomian glands were evaluated with the Cobra® HD infrared meibographer. After 30 days of contact lens wear, the subjects were re-evaluated to determine the changes in conjunctival redness, subjective dry eye disease, tear meniscus height, lipid pattern, and non-invasive break-up time. Results showed that the lipid layer thickness decreased significantly from 2.05 ± 1.53 to 0.92 ± 1.09 Guillon patterns, and the tear meniscus height decreased from 0.21 ± 0.04 to 0.14 ± 0.03. The mean pre-lens non-invasive break-up time (NIBUT) significantly increased from 15.19 ± 9.54 to 25.31 ± 15.81 s. The standard Patient Evaluation of Eye Disease (SPEED) score also decreased from 7.39 ± 4.39 to 5.53 ± 4.83. The results suggest that Lehfilcon A significantly reduced lipid and aqueous tear film volume but improved break-up time and subjective dry eye symptoms. Full article
Show Figures

Figure 1

13 pages, 1567 KiB  
Article
Comparative Evaluation of Pseudomonas aeruginosa Adhesion to a Poly-(2-Methacryloyloxyethyl Phosphorylcholine)-Modified Silicone Hydrogel Contact Lens
by Valerie Harris, Reed Pifer, Paul Shannon and Monica Crary
Vision 2023, 7(1), 27; https://doi.org/10.3390/vision7010027 - 21 Mar 2023
Cited by 4 | Viewed by 3455
Abstract
Pseudomonas aeruginosa is the most common causative agent associated with microbial keratitis. During contact lens wear, pathogens may be introduced into the ocular environment, which might cause adverse events. Lehfilcon A is a recently developed contact lens with a water gradient surface composed [...] Read more.
Pseudomonas aeruginosa is the most common causative agent associated with microbial keratitis. During contact lens wear, pathogens may be introduced into the ocular environment, which might cause adverse events. Lehfilcon A is a recently developed contact lens with a water gradient surface composed of polymeric 2-methacryloyloxyethyl phosphorylcholine (MPC). MPC is re-ported to impart anti-biofouling properties onto modified substrates. Therefore, in this in vitro experimental study, we tested the capability of lehfilcon A to resist adhesion by P. aeruginosa. Quantitative bacterial adhesion assays using five strains of P. aeruginosa were conducted to compare the adherence properties of lehfilcon A to five currently marketed silicone hydrogel (SiHy) contact lenses (comfilcon A, fanfilcon A, senofilcon A, senofilcon C, and samfilcon A). Compared to lehfilcon A, we observed 26.7 ± 8.8 times (p = 0.0028) more P. aeruginosa binding to comfilcon A, 30.0 ± 10.8 times (p = 0.0038) more binding to fanfilcon A, 18.2 ± 6.2 times (p = 0.0034) more binding to senofilcon A, 13.6 ± 3.9 times (p = 0.0019) more binding to senofilcon C, and 29.5 ± 11.8 times (p = 0.0057) more binding to samfilcon A. These results demonstrate that, for various strains of P. aeruginosa, lehfilcon A reduces bacterial adhesion compared to other contact lens materials. Full article
Show Figures

Figure 1

12 pages, 1702 KiB  
Article
Tear Film Dynamics between Low and High Contact Lens Dry Eye Disease Questionnaire (CLDEQ-8) Score with a Lehfilcon A Silicone Hydrogel Water Gradient Contact Lens: A Non-Invasive Methodology Approach
by Raúl Capote-Puente, María-José Bautista-Llamas and José-María Sánchez-González
Diagnostics 2023, 13(5), 939; https://doi.org/10.3390/diagnostics13050939 - 1 Mar 2023
Cited by 8 | Viewed by 2727
Abstract
The purpose of this study is to evaluate the tear film dynamics between individuals with low and high Contact Lens Dry Eye Disease Questionnaire (CLDEQ-8) scores when wearing Lehfilcon A silicone hydrogel water gradient contact lenses. In this study, we implemented a longitudinal, [...] Read more.
The purpose of this study is to evaluate the tear film dynamics between individuals with low and high Contact Lens Dry Eye Disease Questionnaire (CLDEQ-8) scores when wearing Lehfilcon A silicone hydrogel water gradient contact lenses. In this study, we implemented a longitudinal, single-location, self-comparison investigation. Variables measured included conjunctival redness, lipid layer thickness, tear meniscus height, first and mean non-invasive break-up time, CLDEQ-8, and standard patient evaluation of eye dryness (SPEED). In the second phase, participants were re-evaluated after 30 days of wearing the contact lenses to assess the tear film wearing the lenses. In a longitudinal comparison by group, we found that lipid layer thickness decreased 1.52 ± 1.38 (p < 0.01) and 0.70 ± 1.30 (p = 0.01) Guillon patterns degrees in the low and high CLDEQ-8 group, respectively. MNIBUT increased in 11.93 ± 17.93 (p < 0.01) and 7.06 ± 12.07 (p < 0.01) seconds. Finally, LOT increased in 22.19 ± 27.57 (p < 0.01) and 16.87 ± 25.09 (p < 0.01). In conclusion, this study demonstrates the effectiveness of Lehfilcon A silicone hydrogel water gradient contact lenses in improving tear film stability and reducing subjective dry eye symptoms in individuals with low and high CLDEQ-8 scores. However, it also led to an increase in conjunctival redness and a decrease in tear meniscus height. Full article
Show Figures

Figure 1

11 pages, 3129 KiB  
Article
Evaluation of Serratia marcescens Adherence to Contact Lens Materials
by Reed Pifer, Valerie Harris, Deaja Sanders, Monica Crary and Paul Shannon
Microorganisms 2023, 11(1), 217; https://doi.org/10.3390/microorganisms11010217 - 15 Jan 2023
Cited by 3 | Viewed by 3218
Abstract
Bacterial keratitis is a risk associated with the use of contact lenses for cosmetic purposes or vision correction. In this in vitro experimental study, we examined the ability of the ocular pathogen Serratia marcescens to adhere to monthly or biweekly replacement contact lenses. [...] Read more.
Bacterial keratitis is a risk associated with the use of contact lenses for cosmetic purposes or vision correction. In this in vitro experimental study, we examined the ability of the ocular pathogen Serratia marcescens to adhere to monthly or biweekly replacement contact lenses. We performed quantitative adhesion assays to evaluate the adherence of S. marcescens to seven contact lens materials: comfilcon A, senofilcon A, omafilcon B, fanfilcon A, balafilcon A, senofilcon C, and lehfilcon A. Lehfilcon A is a newly marketed silicon hydrogel contact lens with a surface modification of poly-(2-methacryloyloxyethyl phosphorylcholine) (PMPC). PMPC has previously been demonstrated to be an effective anti-biofouling treatment for numerous surfaces. We observed low S. marcescens adherence to lehfilcon A compared to other materials. We demonstrate the use of the fluorescent dye 5(6)-Carboxytetramethylrhodamine succinimidyl ester to covalently stain live cells prior to material adhesion studies. Full article
(This article belongs to the Section Medical Microbiology)
Show Figures

Figure 1

10 pages, 2679 KiB  
Article
Manufacturing of Soft Contact Lenses Using Reusable and Reliable Cyclic Olefin Copolymer Moulds
by Christopher Musgrave, Lorcan O’Toole, Tianyu Mao, Qing Li, Min Lai and Fengzhou Fang
Polymers 2022, 14(21), 4681; https://doi.org/10.3390/polym14214681 - 2 Nov 2022
Cited by 1 | Viewed by 6176
Abstract
We present experimental evidence of reusable, reliable cyclic olefin copolymer (COC) moulds in soft contact lens manufacturing. The moulds showed high performance surface roughness characteristics despite >20 kW exposure to 365 nm ultraviolet (UV) light from repeated use. Ultra-precision manufacturing techniques were used [...] Read more.
We present experimental evidence of reusable, reliable cyclic olefin copolymer (COC) moulds in soft contact lens manufacturing. The moulds showed high performance surface roughness characteristics despite >20 kW exposure to 365 nm ultraviolet (UV) light from repeated use. Ultra-precision manufacturing techniques were used to fabricate transparent COC mould inserts and to produce soft contact lenses from liquid monomer compositions. Both polymer and silicone hydrogels were fabricated with more than 60 individual uses of the moulds. White light interferometry measured the surface roughness (Sa) of the COC moulds to be almost unchanged before and after repeated use (Sa 16.3 nm before vs. 16.6 nm after). The surface roughness of the prototyped lenses and that of commercially available soft contact lenses were then compared by white light interferometry. The surface roughness of the lenses was also nearly unchanged, despite undergoing more than 60 uses of the COC moulds (lens Sa 24.4 nm before vs. after Sa 26.5 nm). By comparison the roughness of the commercial lenses ranged from 9.3–28.5 nm, including conventional and silicone lenses, indicating that the reusable COC moulds produced competitive surface properties. In summary, COC moulds have potential as reusable and reliable mould inserts in the manufacturing of soft contact lenses, yet maintain high quality optical surfaces even after sustained exposure to UV light. Full article
Show Figures

Figure 1

10 pages, 1017 KiB  
Article
Pre-Lens Tear Meniscus Height, Lipid Layer Pattern and Non-Invasive Break-Up Time Short-Term Changes with a Water Gradient Silicone Hydrogel Contact Lens
by Raúl Capote-Puente, María-José Bautista-Llamas, Caterina Manzoni and José-María Sánchez-González
Life 2022, 12(11), 1710; https://doi.org/10.3390/life12111710 - 26 Oct 2022
Cited by 8 | Viewed by 2782
Abstract
To evaluate pre-lens tear film volume, stability and lipid interferometry patterns with a silicone hydrogel water content contact lens, a novel, noninvasive, ocular-surface-analyzer technology was used. A prospective, longitudinal, single-center, self-control study was performed in daily or monthly replacement silicone hydrogel contact lens [...] Read more.
To evaluate pre-lens tear film volume, stability and lipid interferometry patterns with a silicone hydrogel water content contact lens, a novel, noninvasive, ocular-surface-analyzer technology was used. A prospective, longitudinal, single-center, self-control study was performed in daily or monthly replacement silicone hydrogel contact lens wearers. A tear film analysis was achieved with the Integrated Clinical Platform (ICP) Ocular Surface Analyzer (OSA) from SBM System. The subjects were reassessed, with the contact lens, after 30 min of wearing to quantify the volume, stability and lipid pattern of the short-term pre-lens tear film. Lipid layer thickness decreased from 2.05 ± 1.53 to 1.90 ± 1.73 Guillon patterns (p = 0.23). First pre-lens NIBUT decreased from 5.03 ± 1.04 to 4.63 ± 0.89 s (p = 0.01). Mean pre-lens NIBUT significantly increased from 15.19 ± 9.54 to 21.27 ± 11.97 s (p < 0.01). Lid opening time significantly increased from 26.36 ± 19.72 to 38.58 ± 21.78 s (p < 0.01). The silicone hydrogel contact lens with water gradient technology significantly increased the mean pre-lens NIBUT and lid opening time. Lehfilcon A suggested an improvement in contact lens wearers with tear film instability or decreased subjective symptoms of dry eye disease. Full article
(This article belongs to the Special Issue New Horizons in Vision Science, Optometry and Ocular Surface)
Show Figures

Figure 1

18 pages, 842 KiB  
Article
Influence of Selected Ophthalmic Fluids on the Wettability and Hydration of Hydrogel and Silicone Hydrogel Contact Lenses—In Vitro Study
by Gabriela Chwalik-Pilszyk and Anna Wiśniewska
Materials 2022, 15(3), 930; https://doi.org/10.3390/ma15030930 - 25 Jan 2022
Cited by 15 | Viewed by 4502
Abstract
This study attempts to evaluate the effect of incubation in selected ophthalmic fluids on contact lenses (Etafilcon A, Omafilcon A, Narafilcon A, Senofilcon A). Four research groups differing in the incubation environment were created: (1) initial state, (2) contact lens solution (CLS), (3) [...] Read more.
This study attempts to evaluate the effect of incubation in selected ophthalmic fluids on contact lenses (Etafilcon A, Omafilcon A, Narafilcon A, Senofilcon A). Four research groups differing in the incubation environment were created: (1) initial state, (2) contact lens solution (CLS), (3) contact lens solution and eye drops (ED) and (4) eye drops. Dehydration by gravimetric method and the contact angle (CA) by the sessile drop method were tested. The surface free energy (SFE) was also calculated with the use of several methods: Owens–Wendt, Wu, Neumann, and Neumann–Kwok. The greatest changes in the dehydration profile were observed for contact lenses incubated in ED. The most noticeable changes in CA values were observed for contact lenses incubated in ED, in which it was not possible to settle water drop after incubation. On the basis of SFE analysis, higher values were found for hydrogel contact lenses, e.g., according to the Owens–Wendt method, they ranged from 54.45 ± 6.56 mJ/m2 to 58.09 ± 4.86 mJ/m2, while in the case of silicone-hydrogel contact lenses, they ranged from 32.86 ± 3.47 mJ/m2 to 35.33 ± 6.56 mJ/m2. Incubation in all tested environments decreased the SFE values, but the differences were in most cases statistically insignificant. Calculating the SFE may be a useful method as it can be used to estimate the possibility of bacteria adhering to contact lens surfaces. Full article
(This article belongs to the Special Issue Hydrogels in Biology and Medicine)