Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Article Types

Countries / Regions

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Search Results (240)

Search Parameters:
Keywords = print head

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
20 pages, 3402 KB  
Article
Real-Time Monitoring of 3D Printing Process by Endoscopic Vision System Integrated in Printer Head
by Martin Kondrat, Anastasiia Nazim, Kamil Zidek, Jan Pitel, Peter Lazorík and Michal Duhancik
Appl. Sci. 2025, 15(17), 9286; https://doi.org/10.3390/app15179286 - 24 Aug 2025
Viewed by 252
Abstract
This study investigates the real-time monitoring of 3D printing using an endoscopic camera system integrated directly into the print head. The embedded endoscope enables continuous observation of the area surrounding the extruder, facilitating real-time inspection of the currently printed layers. A convolutional neural [...] Read more.
This study investigates the real-time monitoring of 3D printing using an endoscopic camera system integrated directly into the print head. The embedded endoscope enables continuous observation of the area surrounding the extruder, facilitating real-time inspection of the currently printed layers. A convolutional neural network (CNN) is employed to analyse captured images in the direction of print progression, enabling the detection of common defects such as stringing, layer shifting, and inadequate first-layer adhesion. The primary innovation of this work lies in its capacity for online quality assessment and immediate classification of print integrity within predefined thresholds. This system allows for the prompt termination of printing in the case of critical faults or dynamic adjustment of printing parameters in response to minor anomalies. The proposed solution offers a novel pathway for optimising additive manufacturing through real-time feedback on layer formation. Full article
(This article belongs to the Special Issue Real-Time Detection in Additive Manufacturing)
Show Figures

Figure 1

27 pages, 2733 KB  
Article
A Cost-Effective 3D-Printed Conductive Phantom for EEG Sensing System Validation: Development, Performance Evaluation, and Comparison with State-of-the-Art Technologies
by Peter Akor, Godwin Enemali, Usman Muhammad, Jane Crowley, Marc Desmulliez and Hadi Larijani
Sensors 2025, 25(16), 4974; https://doi.org/10.3390/s25164974 - 11 Aug 2025
Viewed by 387
Abstract
This paper presents the development and validation of a cost-effective 3D-printed conductive phantom for EEG sensing system validation that achieves 85% cost reduction (£48.10 vs. £300–£500) and 48-hour fabrication time while providing consistent electrical properties suitable for standardized [...] Read more.
This paper presents the development and validation of a cost-effective 3D-printed conductive phantom for EEG sensing system validation that achieves 85% cost reduction (£48.10 vs. £300–£500) and 48-hour fabrication time while providing consistent electrical properties suitable for standardized electrode testing. The phantom was fabricated using conductive PLA filament in a two-component design with a conductive upper section and a non-conductive base for structural support. Comprehensive validation employed three complementary approaches: DC resistance measurements (821–1502 Ω), complex impedance spectroscopy at 100 Hz across anatomical regions (3.01–6.4 kΩ with capacitive behavior), and 8-channel EEG system testing (5–11 kΩ impedance range). The electrical characterization revealed spatial heterogeneity and consistent electrical properties suitable for comparative electrode evaluation and EEG sensing system validation applications. To establish context, we analyzed six existing phantom technologies including commercial injection-molded phantoms, saline solutions, hydrogels, silicone models, textile-based alternatives, and multi-material implementations. This analysis identifies critical accessibility barriers in current technologies, particularly cost constraints (£5000–20,000 tooling) and extended production timelines that limit widespread adoption. The validated 3D-printed phantom addresses these limitations while providing appropriate electrical properties for standardized EEG electrode testing. The demonstrated compatibility with clinical EEG acquisition systems establishes the phantom’s suitability for electrode performance evaluation and multi-channel system validation as a standardized testing platform, ultimately contributing to democratized access to EEG sensing system validation capabilities for broader research communities. Full article
Show Figures

Figure 1

23 pages, 3081 KB  
Article
Physico-Mechanical Properties of 3D-Printed Filament Materials for Mouthguard Manufacturing
by Maciej Trzaskowski, Gen Tanabe, Hiroshi Churei, Toshiaki Ueno, Michał Ziętala, Bartłomiej Wysocki, Judyta Sienkiewicz, Agata Szczesio-Włodarczyk, Jerzy Sokołowski, Ewa Czochrowska, Małgorzata Zadurska, Elżbieta Mierzwińska-Nastalska, Jolanta Kostrzewa-Janicka and Katarzyna Mańka-Malara
Polymers 2025, 17(16), 2190; https://doi.org/10.3390/polym17162190 - 10 Aug 2025
Viewed by 455
Abstract
Mouthguards are recommended for all sports that may cause injuries to the head and oral cavity. Custom mouthguards, made conventionally in the thermoforming process from ethylene vinyl acetate (EVA), face challenges with thinning at the incisor area during the process. In contrast, additive [...] Read more.
Mouthguards are recommended for all sports that may cause injuries to the head and oral cavity. Custom mouthguards, made conventionally in the thermoforming process from ethylene vinyl acetate (EVA), face challenges with thinning at the incisor area during the process. In contrast, additive manufacturing (AM) processes enable the precise reproduction of the dimensions specified in a computer-aided design (CAD) model. The potential use of filament extrusion materials in the fabrication of custom mouthguards has not yet been explored in comparative studies. Our research aimed to compare five commercially available filaments for the material extrusion (MEX) also known as fused deposition modelling (FDM) of custom mouthguards using a desktop 3D printer. Samples made using Copper 3D PLActive, Spectrum Medical ABS, Braskem Bio EVA, DSM Arnitel ID 2045, and NinjaFlex were compared to EVA Erkoflex, which served as a control sample. The samples underwent tests for ultimate tensile strength (UTS), split Hopkinson pressure bar (SHPB) performance, drop-ball impact, abrasion resistance, absorption, and solubility. The results showed that Copper 3D PLActive and Spectrum Medical ABS had the highest tensile strength. DSM Arnitel ID 2045 had the highest dynamic property performance, measured with the SHPB and drop-ball tests. On the other hand, NinjaFlex exhibited the lowest abrasion resistance and the highest absorption and solubility. DSM Arnitel ID 2045’s absorption and solubility levels were comparable to those of EVA, but had significantly lower abrasion resistance. Ultimately, DSM Arnitel ID 2045 is recommended as the best filament for 3D-printing mouthguards. The properties of this biocompatible material ensure high-impact energy absorption while maintaining low fluid sorption and solubility, supporting its safe intra-oral application for mouthguard fabrication. However, its low abrasion resistance indicated that mouthguards made from this material may need to be replaced more frequently. Full article
(This article belongs to the Special Issue Polymers Composites for Dental Applications, 2nd Edition)
Show Figures

Figure 1

12 pages, 589 KB  
Article
Radial Head Prosthesis with Interconnected Porosity Showing Low Bone Resorption Around the Stem
by Valeria Vismara, Enrico Guerra, Riccardo Accetta, Carlo Cardile, Emanuele Boero, Alberto Aliprandi, Marco Porta, Carlo Zaolino, Alessandro Marinelli, Carlo Cazzaniga and Paolo Arrigoni
J. Clin. Med. 2025, 14(15), 5439; https://doi.org/10.3390/jcm14155439 - 1 Aug 2025
Viewed by 315
Abstract
Background/Objectives: Radial head arthroplasty is a commonly preferred treatment for complex, unreconstructable radial head fractures. Recent studies have raised the question of whether factors such as bone resorption may be related to failure. This observational, retrospective, multicenter, spontaneous, and non-profit study aims [...] Read more.
Background/Objectives: Radial head arthroplasty is a commonly preferred treatment for complex, unreconstructable radial head fractures. Recent studies have raised the question of whether factors such as bone resorption may be related to failure. This observational, retrospective, multicenter, spontaneous, and non-profit study aims to assess radiological outcomes, focusing on bone resorption around the stem, for radial head replacement using a modular, cementless radial head prosthesis with interconnected porosity. Methods: A series of 42 cases was available for review. Patients underwent radial head arthroplasty using a three-dimensional-printed radial head prosthesis. Patients were eligible for inclusion if they had undergone at least one follow-up between 6 and 15 months post-operatively. A scoring system to detect bone resorption was developed and administered by two independent evaluators. Results: Forty-two patients (14 males, 28 females), with an average age of 59 ± 11 years (range: 39–80 years), were analyzed with a minimum of six months’ and a maximum of 32 months’ follow-up. At follow-up, 50 radiological evaluations were collected, with 29 showing ≤3 mm and 12 showing 3–6 mm resorption around the stem. The average resorption was 3.5 mm ± 2.3. No correlation was found between the extent of resorption and the time of follow-up. The developed scoring system allowed for a high level of correlation between the evaluators’ measurements of bone resorption. Conclusions: Radial head prosthesis with interconnected porosity provided a low stem resorption rate for patients after a radial head fracture at short-to-mid-term follow-up after the definition of a reliable and easy-to-use radiological-based classification approach. (Level of Evidence: Level IV). Full article
(This article belongs to the Special Issue Trends and Prospects in Shoulder and Elbow Surgery)
Show Figures

Figure 1

30 pages, 4515 KB  
Article
Implant-Supported Oral Rehabilitation in Head and Neck Cancer Patients: A 20-Year Single-Center Study (2005–2024)
by Manuel Tousidonis, Santiago Ochandiano, Carlos Navarro-Cuellar, Carlos Navarro-Vila, Javier López de Atalaya, Cristina Maza, Ana María Lopez Lopez, Ignacio Navarro-Cuellar, Alba García Sevilla, Gema Arenas de Frutos, Raul Antunez-Conde, Paloma Planells del Pozo and Jose Ignacio Salmeron
J. Clin. Med. 2025, 14(15), 5435; https://doi.org/10.3390/jcm14155435 - 1 Aug 2025
Viewed by 523
Abstract
Background/Objectives: Oral cancer resection often leads to maxillofacial defects and dentition loss, compromising patients’ quality of life. Implant-supported prosthetic rehabilitation offers a reliable solution to restore function, though factors such as bone reconstruction, radiotherapy, and timing of implant placement (immediate vs. delayed) may [...] Read more.
Background/Objectives: Oral cancer resection often leads to maxillofacial defects and dentition loss, compromising patients’ quality of life. Implant-supported prosthetic rehabilitation offers a reliable solution to restore function, though factors such as bone reconstruction, radiotherapy, and timing of implant placement (immediate vs. delayed) may influence outcomes. This study aimed to evaluate long-term implant survival and rehabilitation timelines in oncologic patients, comparing two cohorts (2005–2014 and 2015–2024) to assess the impact of evolving clinical practices. Methods: A retrospective cohort study was conducted at Hospital General Universitario Gregorio Marañón (Madrid, Spain), including 304 patients who underwent ablative oral cancer surgery and subsequent implant-based rehabilitation between 2005 and 2024. Data on demographics, oncologic treatment, reconstruction, implant timing, and prosthetic rehabilitation were collected. Outcomes were compared using Kaplan–Meier analysis and appropriate statistical tests between the 2005–2014 (n = 122) and 2015–2024 (n = 182) cohorts. Results: A total of 2341 Ticare Implants® were placed, supporting 281 prostheses. Implant placement during primary surgery increased from 41% to 71% (p < 0.001). The median time from surgery to prosthesis significantly decreased from 24 to 15 months (p < 0.001). Five-year implant survival was 95% in the early cohort versus 97% in the later cohort. Implant survival was comparable between irradiated and non-irradiated patients (~94–96%). Fixed prostheses became more frequent (92% vs. 79%, p = 0.002). Conclusions: Implant-supported rehabilitation in oncologic patients is highly feasible and durable, with improved timelines and functional outcomes associated with early implant placement and modern digital planning strategies. Full article
(This article belongs to the Special Issue Research Progress in Osseointegrated Oral Implants)
Show Figures

Figure 1

19 pages, 3117 KB  
Article
Feasibility and Accuracy of a Dual-Function AR-Guided System for PSI Positioning and Osteotomy Execution in Pelvic Tumour Surgery: A Cadaveric Study
by Tanya Fernández-Fernández, Javier Orozco-Martínez, Carla de Gregorio-Bermejo, Elena Aguilera-Jiménez, Amaia Iribar-Zabala, Lydia Mediavilla-Santos, Javier Pascau, Mónica García-Sevilla, Rubén Pérez-Mañanes and José Antonio Calvo-Haro
Bioengineering 2025, 12(8), 810; https://doi.org/10.3390/bioengineering12080810 - 28 Jul 2025
Viewed by 402
Abstract
Objectives: Pelvic tumor resections demand high surgical precision to ensure clear margins while preserving function. Although patient-specific instruments (PSIs) improve osteotomy accuracy, positioning errors remain a limitation. This study evaluates the feasibility, accuracy, and usability of a novel dual-function augmented reality (AR) [...] Read more.
Objectives: Pelvic tumor resections demand high surgical precision to ensure clear margins while preserving function. Although patient-specific instruments (PSIs) improve osteotomy accuracy, positioning errors remain a limitation. This study evaluates the feasibility, accuracy, and usability of a novel dual-function augmented reality (AR) system for intraoperative guidance in PSI positioning and osteotomy execution using a head-mounted display (HMD). The system provides dual-function support by assisting both PSI placement and osteotomy execution. Methods: Ten fresh-frozen cadaveric hemipelves underwent AR-assisted internal hemipelvectomy, using customized 3D-printed PSIs and a new in-house AR software integrated into an HMD. Angular and translational deviations between planned and executed osteotomies were measured using postoperative CT analysis. Absolute angular errors were computed from plane normals; translational deviation was assessed as maximum error at the osteotomy corner point in both sagittal (pitch) and coronal (roll) planes. A Wilcoxon signed-rank test and Bland–Altman plots were used to assess intra-workflow cumulative error. Results: The mean absolute angular deviation was 5.11 ± 1.43°, with 86.66% of osteotomies within acceptable thresholds. Maximum pitch and roll deviations were 4.53 ± 1.32 mm and 2.79 ± 0.72 mm, respectively, with 93.33% and 100% of osteotomies meeting translational accuracy criteria. Wilcoxon analysis showed significantly lower angular error when comparing final executed planes to intermediate AR-displayed planes (p < 0.05), supporting improved PSI positioning accuracy with AR guidance. Surgeons rated the system highly (mean satisfaction ≥ 4.0) for usability and clinical utility. Conclusions: This cadaveric study confirms the feasibility and precision of an HMD-based AR system for PSI-guided pelvic osteotomies. The system demonstrated strong accuracy and high surgeon acceptance, highlighting its potential for clinical adoption in complex oncologic procedures. Full article
Show Figures

Figure 1

17 pages, 4176 KB  
Article
Drag Reduction and Efficiency Enhancement in Wide-Range Electric Submersible Centrifugal Pumps via Bio-Inspired Non-Smooth Surfaces: A Combined Numerical and Experimental Study
by Tao Fu, Songbo Wei, Yang Gao and Bairu Shi
Appl. Sci. 2025, 15(14), 7989; https://doi.org/10.3390/app15147989 - 17 Jul 2025
Viewed by 309
Abstract
Wide-range electric submersible centrifugal pumps (ESPs) are critical for offshore oilfields but suffer from narrow high-efficiency ranges and frictional losses under dynamic reservoir conditions. This study introduces bio-inspired dimple-type non-smooth surfaces on impeller blades to enhance hydraulic performance. A combined numerical-experimental approach was [...] Read more.
Wide-range electric submersible centrifugal pumps (ESPs) are critical for offshore oilfields but suffer from narrow high-efficiency ranges and frictional losses under dynamic reservoir conditions. This study introduces bio-inspired dimple-type non-smooth surfaces on impeller blades to enhance hydraulic performance. A combined numerical-experimental approach was employed: a 3D CFD model with the k-ω turbulence model analyzed oil–water flow (1:9 ratio) to identify optimal dimple placement, while parametric studies tested diameters (0.6–1.2 mm). Experimental validation used 3D-printed prototypes. Results revealed that dimples on the pressure surface trailing edge reduced boundary layer separation, achieving a 12.98% head gain and 8.55% efficiency improvement at 150 m3/d in simulations, with experimental tests showing an 11.5% head increase and 4.6% efficiency gain at 130 m3/d. The optimal dimple diameter (0.9 mm, 2% of blade chord) balanced performance and manufacturability, demonstrating that bio-inspired surfaces improve ESP efficiency. This work provides practical guidelines for deploying drag reduction technologies in petroleum engineering, with a future focus on wear resistance in abrasive flows. Full article
Show Figures

Figure 1

14 pages, 3909 KB  
Article
Demonstrating In Situ Formation of Globular Microstructure for Thixotropic Printing of EN AW-4043 Aluminum Alloy
by Silvia Marola and Maurizio Vedani
Metals 2025, 15(7), 804; https://doi.org/10.3390/met15070804 - 17 Jul 2025
Viewed by 370
Abstract
This study explores the feasibility of generating a globular microstructure in situ during the thixotropic 3D printing of the EN AW-4043 alloy, starting from a conventional cold-rolled wire. Thermodynamic simulations using Thermo-Calc software were first conducted to identify the semi-solid processing window of [...] Read more.
This study explores the feasibility of generating a globular microstructure in situ during the thixotropic 3D printing of the EN AW-4043 alloy, starting from a conventional cold-rolled wire. Thermodynamic simulations using Thermo-Calc software were first conducted to identify the semi-solid processing window of the alloy, based on the evolution of liquid and solid fractions as a function of temperature. Guided by these results, thermal treatments were performed on cold-rolled wires to promote the formation of a globular microstructure. A laboratory-scale printing head prototype was then designed and built to test continuous heating and deposition conditions representative of a thixotropic additive manufacturing process. The results showed that a globular microstructure could be achieved in the cold-rolled EN AW-4043 wires by heating them at 590 °C for 5 min in a static muffle furnace. A similar effect was observed when continuously heating the wire while it flowed through the heated printing head. Preliminary deposition tests confirmed the viability of this approach and demonstrated that thixotropic 3D printing of EN AW-4043 alloy is achievable without the need for pre-globular feedstock. Full article
(This article belongs to the Section Additive Manufacturing)
Show Figures

Graphical abstract

17 pages, 2879 KB  
Article
The Impact of Integrating 3D-Printed Phantom Heads of Newborns with Cleft Lip and Palate into an Undergraduate Orthodontic Curriculum: A Comparison of Learning Outcomes and Student Perception
by Sarah Bühling, Jakob Stuhlfelder, Hedi Xandt, Sara Eslami, Lukas Benedikt Seifert, Robert Sader, Stefan Kopp, Nicolas Plein and Babak Sayahpour
Dent. J. 2025, 13(7), 323; https://doi.org/10.3390/dj13070323 - 16 Jul 2025
Viewed by 393
Abstract
Background/Objectives: This prospective intervention study examined the learning effect of using 3D-printed phantom heads with cleft lip and palate (CLP) and upper jaw models with CLP and maxillary plates during a lecture for dental students in their fourth year at J. W. [...] Read more.
Background/Objectives: This prospective intervention study examined the learning effect of using 3D-printed phantom heads with cleft lip and palate (CLP) and upper jaw models with CLP and maxillary plates during a lecture for dental students in their fourth year at J. W. Goethe Frankfurt University. The primary aim was to evaluate the impact of 3D-printed models on students’ satisfaction levels along with their understanding and knowledge in dental education. Methods: Six life-sized phantom heads with removable mandibles (three with unilateral and three with bilateral CLP) were designed using ZBrush software (Pixologic Inc., Los Angeles, CA, USA) based on MRI images and printed with an Asiga Pro 4K 3D printer (Asiga, Sydney, Australia). Two groups of students (n = 81) participated in this study: the control (CTR) group (n = 39) attended a standard lecture on cleft lip and palate, while the intervention (INT) group (n = 42) participated in a hands-on seminar with the same theoretical content, supplemented by 3D-printed models. Before and after the session, students completed self-assessment questionnaires and a multiple-choice test to evaluate knowledge improvement. Data analysis was conducted using the chi-square test for individual questions and the Wilcoxon rank test for knowledge gain, with the significance level set at 0.05. Results: The study demonstrated a significant knowledge increase in both groups following the lecture (p < 0.001). Similarly, there were significant differences in students’ self-assessments before and after the session (p < 0.001). The knowledge gain in the INT group regarding the anatomical features of unilateral cleft lip and palate was significantly higher compared to that in the CTR group (p < 0.05). Conclusions: The results of this study demonstrate the measurable added value of using 3D-printed models in dental education, particularly in enhancing students’ understanding of the anatomy of cleft lip and palate. Full article
(This article belongs to the Special Issue Dental Education: Innovation and Challenge)
Show Figures

Figure 1

15 pages, 1954 KB  
Article
3D-Printed Helmet for Electromagnetic Articulograph Applied in the Study of Oral Physiology
by Franco Marinelli, Francisco Andrés Escobar Jara, Camila Venegas-Ocampo, Josefa Alarcón, Giannina Álvarez, Gloria Cifuentes-Suazo, Marcela Jarpa-Parra, Pablo Navarro, Gladys Morales and Ramón Fuentes Fernández
Appl. Sci. 2025, 15(14), 7913; https://doi.org/10.3390/app15147913 - 16 Jul 2025
Viewed by 408
Abstract
Electromagnetic articulography is a technique developed for recording three-dimensional movements. It is based on magnetic induction, where small currents are induced in miniature receiver coils acting as motion sensors by means of electromagnetic fields generated by transmitter coils. This technology has been applied [...] Read more.
Electromagnetic articulography is a technique developed for recording three-dimensional movements. It is based on magnetic induction, where small currents are induced in miniature receiver coils acting as motion sensors by means of electromagnetic fields generated by transmitter coils. This technology has been applied in dental research to record mandibular movements during mastication, Posselt’s envelope of motion, and micromovements of dental prostheses. The AG501 electromagnetic articulograph (Carstens Medizinelektronik GmbH, Bovenden, Germany) provides a Head Correction (HC) procedure to eliminate head movement, which requires the reference sensors to be firmly attached to the subject’s head. If the sensors shift during the recordings, it becomes necessary to reposition them and repeat the head correction procedure. The aim of this study was to develop a 3D-printed helmet to securely fix the reference sensors to the head of a subject in the context of performing a series of recordings involving the mastication of 36 foods and the execution of Posselt’s envelope of motion. The number of HCs required was recorded for a group using the helmet and for a control group in which the sensors were attached to the subject’s head using tissue adhesive. A total of 29 recordings were conducted with and without the helmet. Without the helmet 44 HCs were required; on the other hand, with the helmet 36 HCs were required. On average, 1.5 HCs were required per session without the helmet and 1.2 HCs with the helmet, showing a non-significant difference (p < 0.05). A reduction in the number of HCs required per session was observed. However, more than one HC was still needed to complete a session. This could be addressed in future research by designing a series of helmets that adapt to different head sizes. Full article
(This article belongs to the Special Issue 3D Printed Materials Dentistry II)
Show Figures

Figure 1

15 pages, 4269 KB  
Article
Accuracy Assessment of 3D-Printed Surgical Guides for Palatal Miniscrew Placement: A Retrospective Study
by Angela Mirea Bellocchio, Elia Ciancio, Serena Barbera, Domenico Aiello, Marco Portelli, Angela Militi and Riccardo Nucera
Appl. Sci. 2025, 15(14), 7836; https://doi.org/10.3390/app15147836 - 13 Jul 2025
Viewed by 490
Abstract
Background: The aim of this retrospective study was to conduct an in vivo evaluation of the accuracy of surgical guides obtained via 3D printing technology that were used to transfer the 3D software-planned position and axis during palatal miniscrew placement. Methods: Twenty-four Caucasian [...] Read more.
Background: The aim of this retrospective study was to conduct an in vivo evaluation of the accuracy of surgical guides obtained via 3D printing technology that were used to transfer the 3D software-planned position and axis during palatal miniscrew placement. Methods: Twenty-four Caucasian subjects with permanent dentition underwent a CBCT examination to plan palatal skeletal anchorage using two miniscrews in the anterior palatal arch. A specific software function capable of identifying and displaying all CBCT scans passing through the planned miniscrew axis was used to identify the scan showing the maximum discrepancy between the planned and final miniscrew placement. The maximum insertion angle discrepancy and the maximum linear difference between the head and tip of the miniscrew were measured on the overlaid 3D STL models of the planned miniscrew position at CBCT with the final clinical position of the miniscrew. Results: Descriptive and inferential statistics were performed. On average, there was a discrepancy between the planned insertion axis and the final insertion axis of 2.95° (SD ± 1.13°), with a 10 mm miniscrew length. Conclusion: Three-dimensional I.-printed surgical guides for palatal miniscrew placement show a mean deviation of 2.95° from the planned position, indicating good but improvable accuracy in placement. Full article
Show Figures

Figure 1

37 pages, 438 KB  
Review
Three-Dimensionally Printed Splints in Dentistry: A Comprehensive Review
by Luka Šimunović, Samir Čimić and Senka Meštrović
Dent. J. 2025, 13(7), 312; https://doi.org/10.3390/dj13070312 - 10 Jul 2025
Viewed by 1257
Abstract
Three-dimensional (3D) printing has emerged as a transformative technology in dental splint fabrication, offering significant advancements in customization, production speed, material efficiency, and patient comfort. This comprehensive review synthesizes the current literature on the clinical use, benefits, limitations, and future directions of 3D-printed [...] Read more.
Three-dimensional (3D) printing has emerged as a transformative technology in dental splint fabrication, offering significant advancements in customization, production speed, material efficiency, and patient comfort. This comprehensive review synthesizes the current literature on the clinical use, benefits, limitations, and future directions of 3D-printed dental splints across various disciplines, including prosthodontics, orthodontics, oral surgery, and restorative dentistry. Key 3D printing technologies such as stereolithography (SLA), digital light processing (DLP), and material jetting are discussed, along with the properties of contemporary photopolymer resins used in splint fabrication. Evidence indicates that while 3D-printed splints generally meet ISO standards for flexural strength and wear resistance, their mechanical properties are often 15–30% lower than those of heat-cured PMMA in head-to-head tests (flexural strength range 50–100 MPa vs. PMMA 100–130 MPa), and study-to-study variability is high. Some reports even show significantly reduced hardness and fatigue resistance in certain resins, underscoring material-specific heterogeneity. Clinical applications reviewed include occlusal stabilization for bruxism and temporomandibular disorders, surgical wafers for orthognathic procedures, orthodontic retainers, and endodontic guides. While current limitations include material aging, post-processing complexity, and variability in long-term outcomes, ongoing innovations—such as flexible resins, multi-material printing, and AI-driven design—hold promise for broader adoption. The review concludes with evidence-based clinical recommendations and identifies critical research gaps, particularly regarding long-term durability, pediatric applications, and quality control standards. This review supports the growing role of 3D printing as an efficient and versatile tool for delivering high-quality splint therapy in modern dental practice. Full article
(This article belongs to the Special Issue Digital Dentures: 2nd Edition)
16 pages, 2092 KB  
Article
Augmented Reality-Assisted Placement of Surgical Guides and Osteotomy Execution for Pelvic Tumour Resections: A Pre-Clinical Feasibility Study Using 3D-Printed Models
by Tanya Fernández-Fernández, Javier Orozco-Martínez, Amaia Iribar-Zabala, Elena Aguilera Jiménez, Carla de Gregorio-Bermejo, Lydia Mediavilla-Santos, Javier Pascau, Mónica García-Sevilla, Rubén Pérez-Mañanes and Jose Antonio Calvo-Haro
Cancers 2025, 17(13), 2260; https://doi.org/10.3390/cancers17132260 - 7 Jul 2025
Viewed by 459
Abstract
Objectives: This pre-clinical feasibility study evaluates the accuracy of a novel augmented reality-based (AR-based) guidance technology using head-mounted displays (HMDs) for the placement of patient-specific instruments (PSIs)—also referred to as surgical guides—and osteotomy performance in pelvic tumour resections. The goal is to [...] Read more.
Objectives: This pre-clinical feasibility study evaluates the accuracy of a novel augmented reality-based (AR-based) guidance technology using head-mounted displays (HMDs) for the placement of patient-specific instruments (PSIs)—also referred to as surgical guides—and osteotomy performance in pelvic tumour resections. The goal is to improve PSI placement accuracy and osteotomy execution while assessing user perception and workflow efficiency. Methods: The study was conducted on ten 3D-printed pelvic phantoms derived from CT scans of cadaveric specimens. Custom PSIs were designed and printed to guide osteotomies at the supraacetabular, symphysial, and ischial regions. An AR application was developed for the HoloLens 2 HMD to display PSI location and cutting planes. The workflow included manual supraacetabular PSI placement, AR-guided placement of the other PSIs and osteotomy execution. Postoperative CT scans were analysed to measure angular and distance errors in PSI placement and osteotomies. Task times and user feedback were also recorded. Results: The mean angular deviation for PSI placement was 2.20°, with a mean distance error of 1.19 mm (95% CI: 0.86 to 1.52 mm). Osteotomies showed an overall mean angular deviation of 3.73° compared to planned cuts, all within the predefined threshold of less than 5°. AR-assisted guidance added less than two minutes per procedure. User feedback highlighted the intuitive interface and high usability, especially for visualising cutting planes. Conclusions: Integrating AR through HMDs is a feasible and accurate method for enhancing PSI placement and osteotomy performance in pelvic tumour resections. The system provides reliable guidance even in cases of PSI failure and adds minimal time to the surgical workflow while significantly improving accuracy. Further validation in cadaveric models is needed to ensure its clinical applicability. Full article
(This article belongs to the Special Issue Clinical Treatment of Osteosarcoma)
Show Figures

Figure 1

28 pages, 25499 KB  
Article
A Combined CFD, Theoretical, and Experimental Approach for Improved Hydrodynamic Performance of a Clam Dredge System
by Rui You and Nathan H. Kennedy
J. Mar. Sci. Eng. 2025, 13(7), 1305; https://doi.org/10.3390/jmse13071305 - 4 Jul 2025
Viewed by 836
Abstract
This paper addresses the need for an integrated approach to develop an improved clam dredge system. Current designs often rely on empirical methods, resulting in a disconnect between theoretical models, computational simulations, and experimental validation. To bridge this gap, the study integrates computational [...] Read more.
This paper addresses the need for an integrated approach to develop an improved clam dredge system. Current designs often rely on empirical methods, resulting in a disconnect between theoretical models, computational simulations, and experimental validation. To bridge this gap, the study integrates computational fluid dynamics (CFD), experimental tests, and analytical methods to develop a clam dredge system. Firstly, the paper introduces an analytical tool that facilitates decision making by evaluating pump parameters, and to determine the operating point for various hose and nozzle parameters. This guides the parameter selection of pump, hose and jets for maximum performance. Secondly, CFD is utilized to analyze flow behavior, enabling the design of internal nozzle geometries that minimize head losses and maximize the scouring effect. A full-scale experimental measurement was conducted to validate computational results. Furthermore, a replica manifold is constructed using 3D printing and tested, demonstrating improvements in jet speed with both original and new nozzle designs. Analytical results indicate that increasing hose length reduces BHP, flow rate, and jet velocity, while increasing hose or jet diameter boosts BHP and flow but reduces jet speed due to pressure drops. Switching pumps reduced power consumption by 10.5% with minimal speed loss. The CFD analysis optimized nozzle design, reducing jet loss and enhancing efficiency. The proposed slit nozzle design reduces the loss coefficient by 85.24% in small-scale runs and by 83% in full-scale runs compared to the original circular jet design. The experiments confirmed the pressure differences between the CFD and experimental tests are within 10%, and demonstrated that rectangular jets increase speed by 9% and seafloor force by 19%. This paper improved the hydrodynamic design of the clam dredge system, and provides a framework for future dredge system designs. Full article
(This article belongs to the Section Ocean Engineering)
Show Figures

Figure 1

32 pages, 5542 KB  
Article
Biodegradable Meets Functional: Dual-Nozzle Printing of Eco-Conscious Parklets with Wood-Filled PLA
by Tomasz Jaróg, Mateusz Góra, Michał Góra, Marcin Maroszek, Krzysztof Hodor, Katarzyna Hodor, Marek Hebda and Magdalena Szechyńska-Hebda
Materials 2025, 18(13), 2951; https://doi.org/10.3390/ma18132951 - 22 Jun 2025
Viewed by 637
Abstract
In the face of accelerating urbanization and the growing demand for environmentally responsible materials and designs, this study presents the development and implementation of a modular parklet demonstrator fabricated using dual-material 3D printing. The structure integrates polylactic acid (PLA) and wood-filled PLA (wood/PLA), [...] Read more.
In the face of accelerating urbanization and the growing demand for environmentally responsible materials and designs, this study presents the development and implementation of a modular parklet demonstrator fabricated using dual-material 3D printing. The structure integrates polylactic acid (PLA) and wood-filled PLA (wood/PLA), combining the mechanical robustness of pure PLA in the core with the tactile and aesthetic appeal of wood-based biocomposite on the surface. The newly developed dual-nozzle 3D printing approach enabled precise spatial control over material distribution, optimizing both structural integrity and sustainability. A comprehensive evaluation was conducted for developed filaments and printed materials, including optical microscopy, coupled thermogravimetry analysis and Fourier Transform Infrared Spectroscopy (TG/FTIR), differential scanning calorimetry (DSC), and chemical and mechanical resistance testing. Results revealed distinct thermal behaviors and degradation pathways between filaments and printed parts composed of PLA and PLA/wood. The biocomposite exhibited slightly increased sensitivity to aggressive chemical environments and mechanical wear, dual-material prints maintained high thermal stability and interlayer adhesion. The 3D-printed demonstrator bench and stools were successfully deployed in public spaces as a functional urban intervention. This work demonstrates the feasibility and advantages of using biocomposite materials and dual-head 3D printing for the rapid, local, and sustainable fabrication of small-scale urban infrastructure. Full article
Show Figures

Figure 1

Back to TopTop