Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (11)

Search Parameters:
Keywords = potentiometric surfactant sensor

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
21 pages, 7086 KB  
Article
Rational Design of a Hydrophobic Ion-Pair Sensor for Potentiometric Determination of Cationic Surfactants in Disinfectants: Combined Experimental and DFT Study
by Marija Kraševac Sakač, Maksym Fizer, Hanna Zhukouskaya, Martin Hrubý, Jiří Pánek, Jasmin Suljagić, Dean Marković, Domagoj Drenjančević, Nikola Sakač, Martina Šrajer Gajdošik and Marija Jozanović
Chemosensors 2026, 14(7), 150; https://doi.org/10.3390/chemosensors14070150 - 1 Jul 2026
Viewed by 337
Abstract
Cationic surfactants are widely used in disinfectants, creating a need for rapid and reliable analytical methods for their determination in complex formulations. In this study, a new hydrophobic ion-pair, 1,3-didecyl-2-methylimidazolium tetrakis(perfluorophenyl)borate (DDMIm–TPFPhB), was developed and applied as an ionophore in a potentiometric sensor. [...] Read more.
Cationic surfactants are widely used in disinfectants, creating a need for rapid and reliable analytical methods for their determination in complex formulations. In this study, a new hydrophobic ion-pair, 1,3-didecyl-2-methylimidazolium tetrakis(perfluorophenyl)borate (DDMIm–TPFPhB), was developed and applied as an ionophore in a potentiometric sensor. The ion-pair was incorporated into a PVC membrane and evaluated by direct potentiometric measurements and titrations. The sensor exhibited near-Nernstian responses toward selected cationic surfactants (56.8–59.1 mV per decade), low detection limits (1.4–2.2 × 10−6 M), and stable signal behavior, along with good selectivity and stability over a pH range of 3–9. Application on commercial disinfectant samples showed good agreement with a commercial ion-selective electrode. According to the charge decomposition analysis performed using density functional theory calculations, the number of electrons donated from perfluorotetraphenyl borate to 1,3-didecyl-2-methylimidazolium is 0.25 e. In contrast, the back-donation from the cation to the anion is only 0.05 e, indicating a relatively substantial overall charge transfer of 0.20 e. This pronounced charge transfer, together with dominant dispersion interactions, contributes to enhanced ion-pair stability within the membrane phase, which is reflected in reduced signal drift and improved analytical performance. These findings establish a direct link between molecular-level interactions and sensor behavior, providing a rational basis for the design of potentiometric sensors for real-sample analysis. Full article
(This article belongs to the Special Issue Potentiometric Sensors in Analytical Chemistry)
Show Figures

Figure 1

14 pages, 1019 KB  
Article
A DODTA–TPB-Based Potentiometric Sensor for Anionic Surfactants: A Computational Design and Environmental Application
by Nada Glumac, Lucija Vrban, Robert Vianello, Marija Jozanović, Maksym Fizer, Marija Kraševac Sakač, Raffaele Velotta, Vincenzo Iannotti, Bartolomeo Della Ventura, Matija Cvetnić, Dean Marković and Nikola Sakač
Chemosensors 2025, 13(9), 321; https://doi.org/10.3390/chemosensors13090321 - 1 Sep 2025
Cited by 2 | Viewed by 1842
Abstract
Surfactants are used in various washing applications with potential negative environmental and health impacts. The ion-pair 1,3-dioctadecyl-1H-1,2,3-triazol-3-ium-tetraphenylborate (DODTA–TPB) was used to fabricate the potentiometric sensor for the quantification of anionic surfactants. The computational analysis of the DODTA+–TPB adduct [...] Read more.
Surfactants are used in various washing applications with potential negative environmental and health impacts. The ion-pair 1,3-dioctadecyl-1H-1,2,3-triazol-3-ium-tetraphenylborate (DODTA–TPB) was used to fabricate the potentiometric sensor for the quantification of anionic surfactants. The computational analysis of the DODTA+–TPB adduct reveals a dynamic, thermodynamically favorable interaction driven primarily by hydrophobic C–H∙∙∙π contacts and the flexibility of the C-18 chains, rather than electrostatic or π–π stacking forces. These findings, supported by the MM-PBSA, RDF, and structural analyses, align with broader trends in molecular recognition and provide a foundation for designing advanced ion-pair-based sensors. The sensor showed advanced analytical properties to anionic surfactants with low interfering effects of selected anions. The response of the SDS was investigated in the range from 8.1 × 10−8 M to 1.0 × 10−2 M, with a slope of −59.2 mV and a limit of detection (LOD) of 3.1 × 10−7 M; and DBS was in the range of 8.1 × 10−8 M to 2.5 × 10−3 M with a slope of −57.5 mV and an LOD of 5.9 × 10−7 M. The sensor was tested on potential interfering ions. Potentiometric titrations of technical-grade anionic surfactants had high recovery rates from 100.2 to 100.4%. The recovery test for spiked samples of surface waters was from 94.2 to 96.5%. The sensor was tested on commercial samples containing anionic surfactants, and the results were compared and showed a good agreement with the two-phase titration method. Full article
Show Figures

Figure 1

13 pages, 4596 KB  
Article
Polyaniline-Based Flexible Sensor for pH Monitoring in Oxidizing Environments
by Liam Bignall, Claire Magnenet, Catheline Ramsamy, Sophie Lakard, Simon Vassal and Boris Lakard
Chemosensors 2024, 12(6), 97; https://doi.org/10.3390/chemosensors12060097 - 3 Jun 2024
Cited by 11 | Viewed by 4626
Abstract
Measuring pH in oxidizing solutions is a crucial issue in areas such as aquaculture, water treatment, industrial chemistry, and environmental analysis. For this purpose, a low-cost potentiometric flexible sensor using a polymer film as a pH-sensitive material has been developed in this study. [...] Read more.
Measuring pH in oxidizing solutions is a crucial issue in areas such as aquaculture, water treatment, industrial chemistry, and environmental analysis. For this purpose, a low-cost potentiometric flexible sensor using a polymer film as a pH-sensitive material has been developed in this study. The sensor consists in a polyaniline film electrodeposited from a sulfuric acid solution on a gold electrode previously deposited on a flexible polyimide substrate. The resulting polyaniline-based pH sensors showed an interesting performance detection in aqueous solution, leading to sensitive (73.4 mV per unit pH) and reproducible (standard deviation of 1.75) responses over the entire pH range from 3 to 8. On the contrary, they were inoperative in the presence of oxidizing hypochlorite ions. Thus, other polyaniline films were electrodeposited in the presence of cetyltrimethylammonium bromide or Tritonx100 surfactant in an attempt to improve the sensing performance of the pH sensors in oxidizing solutions. The pH sensors based on polyaniline and Tritonx100 surfactant were then found to be sensitive (62.3 mV per unit pH) and reproducible (standard deviation of 1.52) in aqueous solutions containing hypochlorite ions. All polyaniline films were also characterized by profilometry and electronic microscopy to correlate the physicochemical features with the performance of the sensors. Full article
Show Figures

Figure 1

14 pages, 16673 KB  
Article
Potentiometric Surfactant Sensor with a Pt-Doped Acid-Activated Multi-Walled Carbon Nanotube-Based Ionophore Nanocomposite
by Nada Glumac, Milan Momčilović, Iztok Kramberger, Darko Štraus, Nikola Sakač, Elvira Kovač-Andrić, Bojan Đurin, Marija Kraševac Sakač, Kristina Đambić and Marija Jozanović
Sensors 2024, 24(8), 2388; https://doi.org/10.3390/s24082388 - 9 Apr 2024
Cited by 1 | Viewed by 2331
Abstract
Two new surfactant sensors were developed by synthesizing Pt-doped acid-activated multi-walled carbon nanotubes (Pt@MWCNTs). Two different ionophores using Pt@MWCNTs, a new plasticizer, and (a) cationic surfactant 1,3-dihexadecyl-1H-benzo[d]imidazol-3-ium-DHBI (Pt@MWCNT-DHBI ionophore) and (b) anionic surfactant dodecylbenzenesulfonate-DBS (Pt@MWCNT-DBS ionophore) composites were successfully synthesized and characterized. Both [...] Read more.
Two new surfactant sensors were developed by synthesizing Pt-doped acid-activated multi-walled carbon nanotubes (Pt@MWCNTs). Two different ionophores using Pt@MWCNTs, a new plasticizer, and (a) cationic surfactant 1,3-dihexadecyl-1H-benzo[d]imidazol-3-ium-DHBI (Pt@MWCNT-DHBI ionophore) and (b) anionic surfactant dodecylbenzenesulfonate-DBS (Pt@MWCNT-DBS ionophore) composites were successfully synthesized and characterized. Both surfactant sensors showed a response to anionic surfactants (dodecylsulfate (SDS) and DBS) and cationic surfactants (cetylpyridinium chloride (CPC) and hexadecyltrimethylammonium bromide (CTAB)). The Pt@MWCNT-DBS sensor showed lower sensitivity than expected with the sub-Nernstian response of ≈23 mV/decade of activity for CPC and CTAB and ≈33 mV/decade of activity for SDS and DBS. The Pt@MWCNT-DHBI surfactant sensor had superior response properties, including a Nernstian response to SDS (59.1 mV/decade) and a near-Nernstian response to DBS (57.5 mV/decade), with linear response regions for both anionic surfactants down to ≈2 × 10−6 M. The Pt@MWCNT-DHBI was also useful in critical micellar concentration (CMC) detection. Common anions showed very low interferences with the sensor. The sensor was successfully employed for the potentiometric titration of a technical grade cationic surfactant with good recoveries. The content of cationic surfactants was measured in six samples of complex commercial detergents. The Pt@MWCNT-DHBI surfactant sensor showed good agreement with the ISE surfactant sensor and classical two-phase titration and could be used as an analytical tool in quality control. Full article
(This article belongs to the Special Issue Advances and Applications of Electrochemical Sensors and Biosensors)
Show Figures

Figure 1

12 pages, 1231 KB  
Article
Study of Cationic Surfactants Raw Materials for COVID-19 Disinfecting Formulations by Potentiometric Surfactant Sensor
by Nikola Sakač, Dubravka Madunić-Čačić, Dean Marković and Marija Jozanović
Sensors 2023, 23(4), 2126; https://doi.org/10.3390/s23042126 - 13 Feb 2023
Cited by 4 | Viewed by 3472
Abstract
The behavior of a new 1,3-dioctadecyl-1H-imidazol-3-ium tetraphenylborate (DODI-TPB) surfactant sensor was studied in single and complex mixtures of technical grade QACs—benzalkonium chloride (BAC), N,N-didecyl-N,N-dimethylammonium chloride (DDAC), and N,N-dioctyl-N,N-dimethylammonium chloride (DOAC) usually used in COVID-19 disinfecting [...] Read more.
The behavior of a new 1,3-dioctadecyl-1H-imidazol-3-ium tetraphenylborate (DODI-TPB) surfactant sensor was studied in single and complex mixtures of technical grade QACs—benzalkonium chloride (BAC), N,N-didecyl-N,N-dimethylammonium chloride (DDAC), and N,N-dioctyl-N,N-dimethylammonium chloride (DOAC) usually used in COVID-19 disinfecting agents formulations. The results obtained with the new DODI-TPB sensor were in good agreement with data measured by a 1,3-dihexadecyl−1H-benzo[d]imidazol−3-ium-tetraphenylborate (DMI-TPB) surfactant sensor, as well as two-phase titration used as a reference method. The quantitative titrations of a two-component mixture of the cationic homologs (a) DDAC and DOAC; and (b) BAC and DOAC showed that the new DODI-TPB surfactant sensor can clearly distinguish two separate mixture components in a single potentiometric titration curve with two characteristic inflexion points. The consumption of SDS (used as a titrant) in the end-point 1 (EP 1) corresponded to the content of DDAC (or BAC), whereas the consumption in the end-point 2 (EP 2) corresponded to the total content of both cationic surfactants in the mixture. DOAC content in both mixtures can be calculated from the difference of the titrant used to achieve EP1 and EP2. The addition of nonionic surfactants resulted in the signal change decrease from 333.2 mV (1:0; no nonionic surfactant added) to 243.0 mV (1:10, w/w). The sensor was successfully tested in ten two-component COVID-19 disinfecting formulations. Full article
(This article belongs to the Special Issue Electrochemical Sensors and Applications)
Show Figures

Figure 1

14 pages, 3494 KB  
Article
Potentiometric Surfactant Sensor for Anionic Surfactants Based on 1,3-dioctadecyl-1H-imidazol-3-ium tetraphenylborate
by Nikola Sakač, Dubravka Madunić-Čačić, Dean Marković, Lucija Hok, Robert Vianello, Valerije Vrček, Bojan Šarkanj, Bojan Đurin, Bartolomeo Della Ventura, Raffaele Velotta and Marija Jozanović
Chemosensors 2022, 10(12), 523; https://doi.org/10.3390/chemosensors10120523 - 8 Dec 2022
Cited by 7 | Viewed by 3146
Abstract
As anionic surfactants are used as cleaning agents, they pose an environmental and health threat. A novel potentiometric sensor for anionic surfactants based on the 1,3-dioctadecyl-1H-imidazol-3-ium tetraphenylborate (DODI–TPB) ionophore is presented. The newly developed approach for DODI–TPB synthesis is faster and [...] Read more.
As anionic surfactants are used as cleaning agents, they pose an environmental and health threat. A novel potentiometric sensor for anionic surfactants based on the 1,3-dioctadecyl-1H-imidazol-3-ium tetraphenylborate (DODI–TPB) ionophore is presented. The newly developed approach for DODI–TPB synthesis is faster and simpler than the currently used strategies and follows the green chemistry principles. The DODI–TPB ionophore was characterized by computational and instrumental techniques (NMR, LC–MS, FTIR, elemental analysis) and used to produce a PVC-based DODI–TPB sensor. The sensor showed linear response to dodecylbenzenesulfonate and dodecyl sulfate in concentration ranges of 6.3 × 10−7–3.2 × 10−4 M and 5.9 × 10−7–4.1 × 10−3 M, for DBS and SDS, respectively. The sensor exhibits a Nernstian slope (59.3 mV/decade and 58.3 mV/decade for DBS and SDS, respectively) and low detection limits (7.1 × 10−7 M and 6.8 × 10−7 M for DBS and SDS, respectively). The DODI–TPB sensor was successfully tested on real samples of commercial detergents and the results are in agreement with the referent methods. A computational analysis underlined the importance of long alkyl chains in DODI+ and their C–H∙∙∙π interactions with TPB for the ionophore formation in solution, thereby providing guidelines for the future design of efficient potentiometric sensors. Full article
(This article belongs to the Special Issue Recent Developments in Electrochemical Sensing)
Show Figures

Figure 1

12 pages, 1987 KB  
Article
The 1,3-Dioctadecyl-1H-imidazol-3-ium Based Potentiometric Surfactant Sensor for Detecting Cationic Surfactants in Commercial Products
by Nikola Sakač, Dubravka Madunić-Čačić, Dean Marković, Bartolomeo Della Ventura, Raffaele Velotta, Anita Ptiček Siročić, Brunislav Matasović, Nikolina Sermek, Bojan Đurin, Bojan Šarkanj and Marija Jozanović
Sensors 2022, 22(23), 9141; https://doi.org/10.3390/s22239141 - 25 Nov 2022
Cited by 10 | Viewed by 2324
Abstract
A low-cost and fast potentiometric surfactant sensor for cationic surfactants, based on the new ion-pair 1,3-dioctadecyl-1H-imidazol-3-ium-tetraphenylborate (DODI-TPB), is presented. The new cationic surfactant DODI-Br was synthesized and characterized by NMR, LC-MS, and elemental analysis, and was used for synthesis of the [...] Read more.
A low-cost and fast potentiometric surfactant sensor for cationic surfactants, based on the new ion-pair 1,3-dioctadecyl-1H-imidazol-3-ium-tetraphenylborate (DODI-TPB), is presented. The new cationic surfactant DODI-Br was synthesized and characterized by NMR, LC-MS, and elemental analysis, and was used for synthesis of the DODI-TPB ionophore. The DODI-TPB surfactant sensor was obtained by implementation of the ionophore in PVC. The sensor showed excellent response characteristics with near-Nernstian slopes to the cationic surfactants DMIC, CPC, CTAB, and Hyamine 1622. The highest voltage responses were obtained for DMIC and CPC (58.7 mV/decade of activity). DMIC had the lowest detection limit (0.9 × 10−6 M) and the broadest useful linear concentration range (1.8 × 10−6 to 1.0 × 10−4 M). An interference study showed remarkable stability. Potentiometric titration curves for the titration of cationic surfactants (DMIC, CPC, CTAB, and Hyamine 1622), with DDS and TPB used as titrants, showed sigmoidal curves with well-defined inflexion points and a broad signal change. The standard addition method was successfully applied with recovery rates from 98.9 to 101.2 at two concentrations. The amount of cationic surfactant found in disinfectants and antiseptics was in good agreement with the referent two-phase titration method and the surfactant sensor on the market. This new surfactant sensor represents a low-cost alternative to existing methods for cationic surfactant detection. Full article
(This article belongs to the Section Chemical Sensors)
Show Figures

Graphical abstract

14 pages, 1878 KB  
Article
Potentiometric Surfactant Sensor Based on 1,3-Dihexadecyl-1H-benzo[d]imidazol-3-ium for Anionic Surfactants in Detergents and Household Care Products
by Nikola Sakač, Dubravka Madunić-Čačić, Dean Marković, Lucija Hok, Robert Vianello, Bojan Šarkanj, Bojan Đurin, Krunoslav Hajdek, Božo Smoljan, Stjepan Milardović, Brunislav Matasović and Marija Jozanović
Molecules 2021, 26(12), 3627; https://doi.org/10.3390/molecules26123627 - 14 Jun 2021
Cited by 11 | Viewed by 4150
Abstract
A 1,3-dihexadecyl-1H-benzo[d]imidazol-3-ium-tetraphenylborate (DHBI-TPB) ion-pair implemented in DHBI-TPB surfactant sensor was used for the potentiometric quantification of anionic surfactants in detergents and commercial household care products. The DHBI-TPB ion-pair was characterized by FTIR spectroscopy and computational analysis which revealed a [...] Read more.
A 1,3-dihexadecyl-1H-benzo[d]imidazol-3-ium-tetraphenylborate (DHBI-TPB) ion-pair implemented in DHBI-TPB surfactant sensor was used for the potentiometric quantification of anionic surfactants in detergents and commercial household care products. The DHBI-TPB ion-pair was characterized by FTIR spectroscopy and computational analysis which revealed a crucial contribution of the C–H∙∙∙π contacts for the optimal complex formation. The DHBI-TPB sensor potentiometric response showed excellent analytical properties and Nernstian slope for SDS (60.1 mV/decade) with LOD 3.2 × 10−7 M; and DBS (58.4 mV/decade) with LOD 6.1 × 10−7 M was obtained. The sensor possesses exceptional resistance to different organic and inorganic interferences in broad pH (2–10) range. DMIC used as a titrant demonstrated superior analytical performances for potentiometric titrations of SDS, compared to other tested cationic surfactants (DMIC > CTAB > CPC > Hyamine 1622). The combination of DHBI-TPB sensor and DMIC was successfully employed to perform titrations of the highly soluble alkane sulfonate homologues. Nonionic surfactants (increased concentration and number of EO groups) had a negative impact on anionic surfactant titration curves and a signal change. The DHBI-TPB sensor was effectively employed for the determination of technical grade anionic surfactants presenting the recoveries from 99.5 to 101.3%. The sensor was applied on twelve powered samples as well as liquid-gel and handwashing home care detergents containing anionic surfactants. The obtained results showed good agreement compared to the outcomes measured by ISE surfactant sensor and a two-phase titration method. The developed DHBI-TPB surfactant sensor could be used for quality control in industry and has great potential in environmental monitoring. Full article
(This article belongs to the Special Issue Last Advances in Cosmetics and Personal Care Products Analysis)
Show Figures

Figure 1

12 pages, 1132 KB  
Article
The Influence of Plasticizers on the Response Characteristics of the Surfactant Sensor for Cationic Surfactant Determination in Disinfectants and Antiseptics
by Nikola Sakač, Dubravka Madunić-Čačić, Maja Karnaš, Bojan Đurin, Ivan Kovač and Marija Jozanović
Sensors 2021, 21(10), 3535; https://doi.org/10.3390/s21103535 - 19 May 2021
Cited by 22 | Viewed by 3942
Abstract
Surfactant liquid-membrane type sensors are usually made of a PVC, ionophore and a plasticizer. Plasticizers soften the PVC. Due to their lipophilicity, they influence the ion exchange across the membrane, ionophore solubility, membrane resistance and, consequently, the analytical signal. We used the DMI-TPB [...] Read more.
Surfactant liquid-membrane type sensors are usually made of a PVC, ionophore and a plasticizer. Plasticizers soften the PVC. Due to their lipophilicity, they influence the ion exchange across the membrane, ionophore solubility, membrane resistance and, consequently, the analytical signal. We used the DMI-TPB as an ionophore, six different plasticizers [2-nitrophenyl-octyl-ether (P1), bis(2-ethylhexyl) phthalate (P2), bis(2-ethylhexyl) sebacate (P3), 2-nitrophenyl phenyl ether (P4), dibutyl phthalate (P5) and dibutyl sebacate (P6)] and a PVC to produce ionic surfactant sensors. Sensor formulation with P1 showed the best potentiometric response to four usually used cationic surfactant, with the lowest LOD, 7 × 10−7 M; and potentiometric titration curves with well-defined and sharp inflexion points. The sensor with P6 showed the lowest analytical performances. Surfactant sensor with P1 was selected for quantification of cationic surfactant in model solutions and commercial samples of disinfectants and antiseptics. It showed high accuracy and precision in all determinations, with recovery from 98.2 to 99.6, and good agreement with the results obtained with surfactant sensor used as a referent one, and a standard two-phase titration method. RDS values were lower than 0.5% for all determinations. Full article
(This article belongs to the Section Chemical Sensors)
Show Figures

Figure 1

16 pages, 1658 KB  
Article
Direct Potentiometric Study of Cationic and Nonionic Surfactants in Disinfectants and Personal Care Products by New Surfactant Sensor Based on 1,3-Dihexadecyl−1H-benzo[d]imidazol−3-ium
by Nikola Sakač, Dean Marković, Bojan Šarkanj, Dubravka Madunić-Čačić, Krunoslav Hajdek, Božo Smoljan and Marija Jozanović
Molecules 2021, 26(5), 1366; https://doi.org/10.3390/molecules26051366 - 4 Mar 2021
Cited by 15 | Viewed by 4066
Abstract
A novel, simple, low-cost, and user-friendly potentiometric surfactant sensor based on the new 1,3-dihexadecyl−1H-benzo[d]imidazol−3-ium-tetraphenylborate (DHBI–TPB) ion-pair for the detection of cationic surfactants in personal care products and disinfectants is presented here. The new cationic surfactant DHBI-Br was successfully synthesized [...] Read more.
A novel, simple, low-cost, and user-friendly potentiometric surfactant sensor based on the new 1,3-dihexadecyl−1H-benzo[d]imidazol−3-ium-tetraphenylborate (DHBI–TPB) ion-pair for the detection of cationic surfactants in personal care products and disinfectants is presented here. The new cationic surfactant DHBI-Br was successfully synthesized and characterized by nuclear magnetic resonance (NMR), Fourier transform infrared (FTIR) spectrometry, liquid chromatography–mass spectrometry (LC–MS) and elemental analysis and was further employed for DHBI–TPB ion-pair preparation. The sensor gave excellent response characteristics for CTAB, CPC and Hyamine with a Nernstian slope (57.1 to 59.1 mV/decade) whereas the lowest limit of detection (LOD) value was measured for CTAB (0.3 × 10−6 M). The sensor exhibited a fast dynamic response to dodecyl sulfate (DDS) and TPB. High sensor performances stayed intact regardless of the employment of inorganic and organic cations and in a broad pH range (2−11). Titration of cationic and etoxylated (EO)-nonionic surfactant (NSs) (in Ba2+) mixtures with TPB revealed the first inflexion point for a cationic surfactant and the second for an EO-nonionic surfactant. The increased concentration of EO-nonionic surfactants and the number of EO groups had a negative influence on titration curves and signal change. The sensor was successfully applied for the quantification of technical-grade cationic surfactants and in 12 personal care products and disinfectants. The results showed good agreement with the measurements obtained by a commercial surfactant sensor and by a two-phase titration. A good recovery for the standard addition method (98–102%) was observed. Full article
(This article belongs to the Special Issue Last Advances in Cosmetics and Personal Care Products Analysis)
Show Figures

Figure 1

3 pages, 178 KB  
Proceeding Paper
The Influence of Plasticizers on Determination of Cationic Surfactants in Pharmaceutical Disinfectants by Direct Potentiometric Surfactant Sensor
by Maja Karnaš, Marija Jozanović, Bojan Đurin and Nikola Sakač
Eng. Proc. 2020, 2(1), 44; https://doi.org/10.3390/ecsa-7-08248 - 14 Nov 2020
Cited by 1 | Viewed by 1799
Abstract
Ion selective liquid membrane type membranes are usually made of a PVC, ionophore and a plasticizer. Plasticizers soften the PVC but due to their lipophilicity they influence the ionophore, the ion exchange across the membrane, membrane resistance and consequently the analytical signal. The [...] Read more.
Ion selective liquid membrane type membranes are usually made of a PVC, ionophore and a plasticizer. Plasticizers soften the PVC but due to their lipophilicity they influence the ionophore, the ion exchange across the membrane, membrane resistance and consequently the analytical signal. The aim of the research was to investigate the influence of four different plasticizers, in formulation with the same ionophore, on the analytical properties of the sensor membrane towards two often used cationic surfactants, then select the best membrane formulation and test it on real samples of six pharmaceutical disinfectants containing cationic surfactants. Full article
(This article belongs to the Proceedings of 7th International Electronic Conference on Sensors and Applications)
Show Figures

Figure 1

Back to TopTop