Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (55)

Search Parameters:
Keywords = portable ultrasound system

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
20 pages, 3318 KB  
Review
Review of Linear-Array-Transducer-Based Volumetric Ultrasound Imaging Techniques and Their Biomedical Applications
by Ninjbadgar Tsedendamba, Yuon Song, Eun-Yeong Park and Jeesu Kim
Bioengineering 2025, 12(9), 906; https://doi.org/10.3390/bioengineering12090906 - 23 Aug 2025
Viewed by 274
Abstract
Ultrasound imaging is one of the most widespread biomedical imaging techniques thanks to its advantages such as being non-invasive, portable, non-ionizing, and cost-effective. Ultrasound imaging generally provides two-dimensional cross-sectional images, but the quality and interpretative ability vary based on the experience of the [...] Read more.
Ultrasound imaging is one of the most widespread biomedical imaging techniques thanks to its advantages such as being non-invasive, portable, non-ionizing, and cost-effective. Ultrasound imaging generally provides two-dimensional cross-sectional images, but the quality and interpretative ability vary based on the experience of the examiner, leading to a lack of objectivity and accuracy. To address these issues, there is a growing demand for three-dimensional ultrasound imaging. Among the various types of transducers used to obtain three-dimensional ultrasound images, this paper focuses on the most standardized probe, the linear array transducer, and provides an overview of the system implementations, imaging results, and applications of volumetric ultrasound imaging from the perspective of scanning methods. Through this comprehensive review, future researchers will gain insights into the advantages and disadvantages of various approaches to three-dimensional imaging systems using linear arrays, providing direction and applicability for system configuration and application. Full article
Show Figures

Figure 1

14 pages, 2579 KB  
Article
Prediction of Subcutaneous Fat Thickness (SFT) in Pantaneiro Lambs: A Model Based on Adipometer and Body Measurements for Android Application
by Adrielly Lais Alves da Silva, Marcus Vinicius Porto dos Santos, Marcelo Corrêa da Silva, Hélio Almeida Ricardo, Marcio Rodrigues de Souza, Núbia Michelle Vieira da Silva and Fernando Miranda de Vargas Junior
AgriEngineering 2025, 7(8), 251; https://doi.org/10.3390/agriengineering7080251 - 7 Aug 2025
Viewed by 685
Abstract
The increasing adoption of digital technologies in the agriculture sector has significantly contributed to optimizing on-farm routines, especially in data-driven decision-making. This study aimed to develop an application to determine the slaughter point of lambs by predicting subcutaneous fat thickness (SFT) using pre-slaughter [...] Read more.
The increasing adoption of digital technologies in the agriculture sector has significantly contributed to optimizing on-farm routines, especially in data-driven decision-making. This study aimed to develop an application to determine the slaughter point of lambs by predicting subcutaneous fat thickness (SFT) using pre-slaughter parameters such as body weight (BW), body condition score (BCS), and skinfold measurements at the brisket (BST), lumbar (LST), and tail base (TST), obtained using an adipometer. A total of 45 Pantaneiros lambs were evaluated, finished in feedlot, and slaughtered at different body weights. Each pre-slaughter weight class showed a distinct carcass pattern when all parameters were included in the model. Exploratory analysis revealed statistical significance for all variables (p < 0.001). BW and LST were selected to construct the predictive equation (R2 = 55.44%). The regression equations were integrated into the developed application, allowing for in-field estimation of SFT based on simple measurements. Compared to conventional techniques such as ultrasound or visual scoring, this tool offers advantages in portability, objectivity, and immediate decision-making support. In conclusion, combining accessible technologies (e.g., adipometer) with traditional variables (e.g., body weight), represents an effective alternative for production systems aimed at optimizing and enhancing the value of lamb carcasses. Full article
Show Figures

Graphical abstract

14 pages, 1227 KB  
Article
Reliability and Inter-Device Agreement Between a Portable Handheld Ultrasound Scanner and a Conventional Ultrasound System for Assessing the Thickness of the Rectus Femoris and Vastus Intermedius
by Carlante Emerson, Hyun K. Kim, Brian A. Irving and Efthymios Papadopoulos
J. Funct. Morphol. Kinesiol. 2025, 10(3), 299; https://doi.org/10.3390/jfmk10030299 - 1 Aug 2025
Viewed by 311
Abstract
Background: Ultrasound (U/S) can be used to evaluate skeletal muscle characteristics in clinical and sports settings. Handheld U/S devices have recently emerged as a cheaper and portable alternative to conventional U/S systems. However, further research is warranted on their reliability. We assessed [...] Read more.
Background: Ultrasound (U/S) can be used to evaluate skeletal muscle characteristics in clinical and sports settings. Handheld U/S devices have recently emerged as a cheaper and portable alternative to conventional U/S systems. However, further research is warranted on their reliability. We assessed the reliability and inter-device agreement between a handheld U/S device (Clarius L15 HD3) and a more conventional U/S system (GE LOGIQ e) for measuring the thickness of the rectus femoris (RF) and vastus intermedius (VI). Methods: Cross-sectional images of the RF and VI muscles were obtained in 20 participants by two assessors, and on two separate occasions by one of those assessors, using the Clarius L15 HD3 and GE LOGIQ e devices. RF and VI thickness measurements were obtained to determine the intra-rater reliability, inter-rater reliability, and inter-device agreement. Results: All intraclass correlation coefficients (ICCs) were above 0.9 for intra-rater reliability (range: 0.94 to 0.97), inter-rater reliability (ICC: 0.97), and inter-device agreement (ICC: 0.98) when comparing the two devices in assessing RF and VI thickness. For the RF, the Bland–Altman plot revealed a mean difference of 0.06 ± 0.07 cm, with limits of agreement ranging from 0.21 to −0.09, whereas for the VI, the Bland–Altman plot showed a mean difference of 0.07 ± 0.10 cm, with limits of agreement ranging from 0.27 to −0.13. Conclusions: The handheld Clarius L15 HD3 was reliable and demonstrated high agreement with the more conventional GE LOGIQ e for assessing the thickness of the RF and VI in young, healthy adults. Full article
(This article belongs to the Section Kinesiology and Biomechanics)
Show Figures

Figure 1

40 pages, 6280 KB  
Review
Ultrasound in the Food Industry: Mechanisms and Applications for Non-Invasive Texture and Quality Analysis
by Nama Yaa Akyea Prempeh, Xorlali Nunekpeku, Arul Murugesan and Huanhuan Li
Foods 2025, 14(12), 2057; https://doi.org/10.3390/foods14122057 - 11 Jun 2025
Cited by 2 | Viewed by 2956
Abstract
Ultrasound technology has emerged as a transformative tool in modern food science, offering non-destructive, real-time assessment and enhancement of food quality attributes. This review systematically explores the fundamental mechanisms by which ultrasound interacts with food matrices, including mechanical effects such as acoustic cavitation, [...] Read more.
Ultrasound technology has emerged as a transformative tool in modern food science, offering non-destructive, real-time assessment and enhancement of food quality attributes. This review systematically explores the fundamental mechanisms by which ultrasound interacts with food matrices, including mechanical effects such as acoustic cavitation, localized shear forces, and microstreaming, as well as thermal and acoustic attenuation phenomena. Applications of ultrasound in food texture evaluation are discussed across multiple sectors, with particular emphasis on its role in assessing moisture distribution, fat content, structural integrity, and microstructural alterations in meat, dairy, fruits, and vegetables. The versatility of ultrasound—spanning low-intensity quality assessments to high-intensity processing interventions—makes it an invaluable technology for both quality control and product innovation. Moreover, emerging innovations such as ultrasound-assisted extraction, non-thermal pasteurization, and real-time quality monitoring are highlighted, demonstrating the synergy between ultrasound and advanced technologies like AI-driven data interpretation and portable, handheld sensing devices. Despite these advances, challenges related to technical limitations in heterogeneous food systems, high initial investment costs, scalability, and the absence of standardized protocols remain critical barriers to widespread adoption. The future directions emphasize the integration of ultrasound with multi-modal approaches, the development of miniaturized and cost-effective equipment, and the establishment of global regulatory standards to facilitate its broader application. Overall, ultrasound is positioned as a key enabler for sustainable, efficient, and non-invasive quality assurance across the global food industry. Full article
(This article belongs to the Section Food Engineering and Technology)
Show Figures

Figure 1

13 pages, 1502 KB  
Article
ASFmeter: A Portable A-Mode Ultrasound Device for Abdominal Subcutaneous Fat Thickness Measurement
by Hongyang Zhao, Ran Liu, Guangfei Li, Zhou Zhang, Yanxin Wang, Man Ji, Lin Yang and Dongmei Hao
Bioengineering 2025, 12(6), 567; https://doi.org/10.3390/bioengineering12060567 - 26 May 2025
Viewed by 660
Abstract
Background: Obesity is a global health concern linked to an elevated risk of chronic diseases. Abdominal subcutaneous fat (ASF) thickness serves as a key indicator for obesity assessment; however, existing measurement methods often lack simplicity and accessibility. Methods: We developed the ASFmeter, a [...] Read more.
Background: Obesity is a global health concern linked to an elevated risk of chronic diseases. Abdominal subcutaneous fat (ASF) thickness serves as a key indicator for obesity assessment; however, existing measurement methods often lack simplicity and accessibility. Methods: We developed the ASFmeter, a portable, low-cost A-mode ultrasound device designed for rapid ASF thickness measurement. Forty participants underwent ASF thickness assessment using both the ASFmeter and a conventional B-mode ultrasound system, demonstrating strong agreement (R2 = 0.94, SEE = 1.72 mm). Statistical analyses evaluated correlations between ASF thickness and body weight, abdominal circumference, and body mass index (BMI). Results: the ASFmeter exhibited high consistency with B-mode ultrasound measurements, confirming its accuracy. Significant variations in ASF thickness were observed across BMI groups, supporting its utility as a reliable obesity indicator. Conclusions: the ASFmeter offers a user-friendly, portable, and cost-effective solution for ASF measurement, facilitating personal health monitoring and obesity-related risk assessment. This innovation holds promise for widespread application in home-based health management. Full article
(This article belongs to the Section Biomedical Engineering and Biomaterials)
Show Figures

Figure 1

17 pages, 2467 KB  
Article
Quantitative Ultrasound Texture Analysis of Breast Tumors: A Comparison of a Cart-Based and a Wireless Ultrasound Scanner
by David Alberico, Lakshmanan Sannachi, Maria Lourdes Anzola Pena, Joyce Yip, Laurentius O. Osapoetra, Schontal Halstead, Daniel DiCenzo, Sonal Gandhi, Frances Wright, Michael Oelze and Gregory J. Czarnota
J. Imaging 2025, 11(5), 146; https://doi.org/10.3390/jimaging11050146 - 6 May 2025
Viewed by 899
Abstract
Previous work has demonstrated quantitative ultrasound (QUS) analysis techniques for extracting features and texture features from ultrasound radiofrequency data which can be used to distinguish between benign and malignant breast masses. It is desirable that there be good agreement between estimates of such [...] Read more.
Previous work has demonstrated quantitative ultrasound (QUS) analysis techniques for extracting features and texture features from ultrasound radiofrequency data which can be used to distinguish between benign and malignant breast masses. It is desirable that there be good agreement between estimates of such features acquired using different ultrasound devices. Handheld ultrasound imaging systems are of particular interest as they are compact, relatively inexpensive, and highly portable. This study investigated the agreement between QUS parameters and texture features estimated from clinical ultrasound images of breast tumors acquired using two different ultrasound scanners: a traditional cart-based system and a wireless handheld ultrasound system. The 28 patients who participated were divided into two groups (benign and malignant). The reference phantom technique was used to produce functional estimates of the normalized power spectra and backscatter coefficient for each image. Root mean square differences of feature estimates were calculated for each cohort to quantify the level of feature variation attributable to tissue heterogeneity and differences in system imaging parameters. Cross-system statistical testing using the Mann–Whitney U test was performed on benign and malignant patient cohorts to assess the level of feature estimate agreement between systems, and the Bland–Altman method was employed to assess feature sets for systematic bias introduced by differences in imaging method. The range of p-values was 1.03 × 10−4 to 0.827 for the benign cohort and 3.03 × 10−10 to 0.958 for the malignant cohort. For both cohorts, all five of the primary QUS features (MBF, SS, SI, ASD, AAC) were found to be in agreement at the 5% confidence level. A total of 13 of the 20 QUS texture features (65%) were determined to exhibit statistically significant differences in the sample medians of estimates between systems at the 5% confidence level, with the remaining 7 texture features being in agreement. The results showed a comparable magnitude of feature variation between tissue heterogeneity and system effects, as well as a moderate level of statistical agreement between feature sets. Full article
(This article belongs to the Section Medical Imaging)
Show Figures

Figure 1

15 pages, 3015 KB  
Article
Noise Reduction in LED-Based Photoacoustic Imaging
by Takahiro Kono, Kazuma Hashimoto, Keisuke Fukuda, Uma Maheswari Rajagopalan, Kae Nakamura and Jun Yamada
Photonics 2025, 12(4), 398; https://doi.org/10.3390/photonics12040398 - 18 Apr 2025
Viewed by 512
Abstract
Photoacoustic tomography (PAT), also known as optoacoustic tomography, has been emerging as a biomedical imaging modality that can provide cross-sectional or three-dimensional (3D) visualization of biological tissues such as blood vessels and lymphatic vessels in vivo at high resolution. The principle behind the [...] Read more.
Photoacoustic tomography (PAT), also known as optoacoustic tomography, has been emerging as a biomedical imaging modality that can provide cross-sectional or three-dimensional (3D) visualization of biological tissues such as blood vessels and lymphatic vessels in vivo at high resolution. The principle behind the visualization involves the light being absorbed by the tissues which results in the generation of ultrasound. Depending on the strength of ultrasound and its decay rate, it could be used to visualize the absorber location. In general, pulsed lasers such as the Q-switched Nd-YAG and OPO lasers that provide high-energy widths in the range of a few nanoseconds operating at low repetition rates are commonly used as a light source in photoacoustic imaging. However, such lasers are expensive and occupy ample space. Therefore, PAT systems that use LED as the source instead of lasers, which have the advantage of being obtainable at low cost and portable, are gaining attention. However, LED light sources have significantly low energy, and the photoacoustic signals generated have a low signal-to-noise ratio (SNR). Therefore, in LED-based systems, one way to strengthen the signal and improve the SNR is to significantly increase the repetition rate of LED pulses and use signal processing, which can be achieved using a high-power LED along M-sequence signal decoding. M-sequence signal decoding is effective, especially under high repetition rates, thus improving the SNR. However, power supplies for high-power LEDs have a circuit jitter, resulting in random temporal fluctuations in the emitted light. Such jitters, in turn, would affect the M-sequence-based signal decoding. Therefore, we propose a new decoding algorithm which compensates for LED jitter in the M-sequence signal processing. We show that the proposed new signal processing method can significantly improve the SNR of the photoacoustic signals. Full article
(This article belongs to the Special Issue Emerging Trends in Biomedical Optical Imaging)
Show Figures

Figure 1

15 pages, 2246 KB  
Article
Cost-Effective Photoacoustic Imaging Using High-Power Light-Emitting Diodes Driven by an Avalanche Oscillator
by Alberto Prud’homme and Frederic Nabki
Sensors 2025, 25(6), 1643; https://doi.org/10.3390/s25061643 - 7 Mar 2025
Cited by 2 | Viewed by 1225
Abstract
Photoacoustic imaging (PAI) is an emerging modality that merges optical and ultrasound imaging to provide high-resolution and functional insights into biological tissues. This technique leverages the photoacoustic effect, where tissue absorbs pulsed laser light, generating acoustic waves that are captured to reconstruct images. [...] Read more.
Photoacoustic imaging (PAI) is an emerging modality that merges optical and ultrasound imaging to provide high-resolution and functional insights into biological tissues. This technique leverages the photoacoustic effect, where tissue absorbs pulsed laser light, generating acoustic waves that are captured to reconstruct images. While lasers have traditionally been the light source for PAI, their high cost and complexity drive interest towards alternative sources like light-emitting diodes (LEDs). This study evaluates the feasibility of using an avalanche oscillator to drive high-power LEDs in a basic photoacoustic imaging system. An avalanche oscillator, utilizing semiconductor avalanche breakdown to produce high-voltage pulses, powers LEDs to generate short, high-intensity light pulses. The system incorporates an LED array, an ultrasonic transducer, and an amplifier for signal detection. Key findings include the successful generation of short light pulses with sufficient intensity to excite materials and the system’s capability to produce detectable photoacoustic signals in both air and water environments. While LEDs demonstrate cost-effectiveness and portability advantages, challenges such as lower power and broader spectral bandwidth compared to lasers are noted. The results affirm that LED-based photoacoustic systems, though currently less advanced than laser-based systems, present a promising direction for affordable and portable imaging technologies. Full article
(This article belongs to the Special Issue Photonics for Advanced Spectroscopy and Sensing)
Show Figures

Figure 1

12 pages, 1901 KB  
Article
Advancing Near-Infrared Probes for Enhanced Breast Cancer Assessment
by Mohammad Pouriayevali, Ryley McWilliams, Avner Bachar, Parmveer Atwal, Ramani Ramaseshan and Farid Golnaraghi
Sensors 2025, 25(3), 983; https://doi.org/10.3390/s25030983 - 6 Feb 2025
Cited by 1 | Viewed by 1418
Abstract
Breast cancer remains a leading cause of cancer-related deaths among women, emphasizing the critical need for early detection and monitoring techniques. Conventional imaging modalities such as mammography, MRI, and ultrasound have face sensitivity, specificity, cost, and patient comfort limitations. This study introduces a [...] Read more.
Breast cancer remains a leading cause of cancer-related deaths among women, emphasizing the critical need for early detection and monitoring techniques. Conventional imaging modalities such as mammography, MRI, and ultrasound have face sensitivity, specificity, cost, and patient comfort limitations. This study introduces a handheld Near-Infrared Diffuse Optical Tomography (NIR DOT) probe for breast cancer imaging. The NIRscan probe utilizes multi-wavelength light-emitting diodes (LEDs) and a linear charge-coupled device (CCD) sensor to acquire real-time optical data, reconstructing cross-sectional images of breast tissue based on scattering and absorption coefficients. With wavelengths optimized for the differential optical properties of tissue components, the probe enables functional imaging, distinguishing between healthy and malignant tissues. Clinical evaluations have demonstrated its potential for precise tumor localization and monitoring therapeutic responses, achieving a sensitivity of 94.7% and specificity of 84.2%. By incorporating machine learning algorithms and a modified diffusion equation (MDE), the system enhances the accuracy and speed of image reconstruction, supporting rapid, non-invasive diagnostics. This development represents a significant step forward in portable, cost-effective solutions for breast cancer detection, with potential applications in low-resource settings and diverse clinical environments. Full article
(This article belongs to the Special Issue Advanced Sensors for Detection of Cancer Biomarkers and Virus)
Show Figures

Figure 1

17 pages, 4755 KB  
Article
Comparison of Immersion and Portable Ultrasonic Housing to Quantify the Adhesive Bond Thickness and Sizing of Foreign Objects
by Nathaniel J. Blackman, Benjamin M. Blandford and David A. Jack
Materials 2024, 17(20), 5111; https://doi.org/10.3390/ma17205111 - 19 Oct 2024
Viewed by 1056
Abstract
High-performance materials, such as carbon fiber laminates, are costly to manufacture and are often used in demanding environments requiring the use of high-resolution non-destructive testing (NDT) methods to confirm the integrity of the parts. One NDT method that has shown promise for qualifying [...] Read more.
High-performance materials, such as carbon fiber laminates, are costly to manufacture and are often used in demanding environments requiring the use of high-resolution non-destructive testing (NDT) methods to confirm the integrity of the parts. One NDT method that has shown promise for qualifying carbon fiber laminates is the use of immersion ultrasound with spherically focused probes. However, many parts may not be submersible in an immersion tank due to size or material constraints. These parts must be scanned with contact transducers with inferior resolutions or with expensive and messy systems such as bubblers. This research presents the use of a novel housing system that allows for the use of focused immersion transducers in an out-of-tank portable ultrasonic scanning application. This work presents a comparison between scans taken using a custom high-resolution immersion system and scans taken using the presented housing. There are a wide variety of potential inspection applications for this novel system, and the present work focused on two specific applications: the quantification of the spatially varying adhesive thickness in bonded carbon fiber laminates and the quantification of foreign object inclusions in carbon fiber laminates. The results presented show that scans using the portable housing are comparable in quality to scans performed using an immersion system. Specifically, both inspection approaches had an average error of 0.04 mm when quantifying the adhesive thickness of a bonded composite, and for the foreign object detection, the error in quantifying the dimensions of the embedded foreign object was 0.1 mm and 0.2 mm for the immersion system and the portable inspection system, respectively. The demonstration was performed in a laboratory setting, but a discussion is provided for the necessary improvements needed to extend the system for use in field applications. Full article
(This article belongs to the Special Issue Non-Destructive Testing (NDT) of Advanced Composites and Structures)
Show Figures

Figure 1

23 pages, 11804 KB  
Article
Therapeutic Exercise Recognition Using a Single UWB Radar with AI-Driven Feature Fusion and ML Techniques in a Real Environment
by Shahzad Hussain, Hafeez Ur Rehman Siddiqui, Adil Ali Saleem, Muhammad Amjad Raza, Josep Alemany Iturriaga, Alvaro Velarde-Sotres and Isabel De la Torre Díez
Sensors 2024, 24(17), 5533; https://doi.org/10.3390/s24175533 - 27 Aug 2024
Cited by 1 | Viewed by 1573
Abstract
Physiotherapy plays a crucial role in the rehabilitation of damaged or defective organs due to injuries or illnesses, often requiring long-term supervision by a physiotherapist in clinical settings or at home. AI-based support systems have been developed to enhance the precision and effectiveness [...] Read more.
Physiotherapy plays a crucial role in the rehabilitation of damaged or defective organs due to injuries or illnesses, often requiring long-term supervision by a physiotherapist in clinical settings or at home. AI-based support systems have been developed to enhance the precision and effectiveness of physiotherapy, particularly during the COVID-19 pandemic. These systems, which include game-based or tele-rehabilitation monitoring using camera-based optical systems like Vicon and Microsoft Kinect, face challenges such as privacy concerns, occlusion, and sensitivity to environmental light. Non-optical sensor alternatives, such as Inertial Movement Units (IMUs), Wi-Fi, ultrasound sensors, and ultrawide band (UWB) radar, have emerged to address these issues. Although IMUs are portable and cost-effective, they suffer from disadvantages like drift over time, limited range, and susceptibility to magnetic interference. In this study, a single UWB radar was utilized to recognize five therapeutic exercises related to the upper limb, performed by 34 male volunteers in a real environment. A novel feature fusion approach was developed to extract distinguishing features for these exercises. Various machine learning methods were applied, with the EnsembleRRGraBoost ensemble method achieving the highest recognition accuracy of 99.45%. The performance of the EnsembleRRGraBoost model was further validated using five-fold cross-validation, maintaining its high accuracy. Full article
Show Figures

Figure 1

14 pages, 4051 KB  
Article
Validation of an Artificial Intelligence-Based Ultrasound Imaging System for Quantifying Muscle Architecture Parameters of the Rectus Femoris in Disease-Related Malnutrition (DRM)
by Sergio García-Herreros, Juan Jose López Gómez, Angela Cebria, Olatz Izaola, Pablo Salvador Coloma, Sara Nozal, Jesús Cano, David Primo, Eduardo Jorge Godoy and Daniel de Luis
Nutrients 2024, 16(12), 1806; https://doi.org/10.3390/nu16121806 - 8 Jun 2024
Cited by 9 | Viewed by 2294
Abstract
(1) Background: The aim was to validate an AI-based system compared to the classic method of reading ultrasound images of the rectus femur (RF) muscle in a real cohort of patients with disease-related malnutrition. (2) Methods: One hundred adult patients with DRM aged [...] Read more.
(1) Background: The aim was to validate an AI-based system compared to the classic method of reading ultrasound images of the rectus femur (RF) muscle in a real cohort of patients with disease-related malnutrition. (2) Methods: One hundred adult patients with DRM aged 18 to 85 years were enrolled. The risk of DRM was assessed by the Global Leadership Initiative on Malnutrition (GLIM). The variation, reproducibility, and reliability of measurements for the RF subcutaneous fat thickness (SFT), muscle thickness (MT), and cross-sectional area (CSA), were measured conventionally with the incorporated tools of a portable ultrasound imaging device (method A) and compared with the automated quantification of the ultrasound imaging system (method B). (3) Results: Measurements obtained using method A (i.e., conventionally) and method B (i.e., raw images analyzed by AI), showed similar values with no significant differences in absolute values and coefficients of variation, 58.39–57.68% for SFT, 30.50–28.36% for MT, and 36.50–36.91% for CSA, respectively. The Intraclass Correlation Coefficient (ICC) for reliability and consistency analysis between methods A and B showed correlations of 0.912 and 95% CI [0.872–0.940] for SFT, 0.960 and 95% CI [0.941–0.973] for MT, and 0.995 and 95% CI [0.993–0.997] for CSA; the Bland–Altman Analysis shows that the spread of points is quite uniform around the bias lines with no evidence of strong bias for any variable. (4) Conclusions: The study demonstrated the consistency and reliability of this new automatic system based on machine learning and AI for the quantification of ultrasound imaging of the muscle architecture parameters of the rectus femoris muscle compared with the conventional method of measurement. Full article
(This article belongs to the Special Issue Morphofunctional Nutritional Assessment in Clinical Practice)
Show Figures

Figure 1

18 pages, 10855 KB  
Article
Nondestructive Inspection and Quantification of Select Interface Defects in Honeycomb Sandwich Panels
by Mahsa Khademi, Daniel P. Pulipati and David A. Jack
Materials 2024, 17(11), 2772; https://doi.org/10.3390/ma17112772 - 6 Jun 2024
Cited by 1 | Viewed by 1494
Abstract
Honeycomb sandwich panels are utilized in many industrial applications due to their high bending resistance relative to their weight. Defects between the core and the facesheet compromise their integrity and efficiency due to the inability to transfer loads. The material system studied in [...] Read more.
Honeycomb sandwich panels are utilized in many industrial applications due to their high bending resistance relative to their weight. Defects between the core and the facesheet compromise their integrity and efficiency due to the inability to transfer loads. The material system studied in the present paper is a unidirectional carbon fiber composite facesheet with a honeycomb core with a variety of defects at the interface between the two material systems. Current nondestructive techniques focus on defect detectability, whereas the presented method uses high-frequency ultrasound testing (UT) to detect and quantify the defect geometry and defect type. Testing is performed using two approaches, a laboratory scale immersion tank and a novel portable UT system, both of which utilize only single-side access to the part. Coupons are presented with defects spanning from 5 to 40 mm in diameter, whereas defects in the range of 15–25 mm and smaller are considered below the detectability limits of existing inspection methods. Defect types studied include missing adhesive, unintentional foreign objects that occur during the manufacturing process, damaged core, and removed core sections. An algorithm is presented to quantify the defect perimeter. The provided results demonstrate successful defect detection, with an average defect diameter error of 0.6 mm across all coupons studied in the immersion system and 1.1 mm for the portable system. The best accuracy comes from the missing adhesive coupons, with an average error of 0.3 mm. Conversely, the worst results come from the missing or damaged honeycomb coupons, with an error average of 0.7 mm, well below the standard detectability levels of 15–25 mm. Full article
Show Figures

Figure 1

14 pages, 1754 KB  
Article
A New Quantitative Tool for the Ultrasonographic Assessment of Tendons: A Reliability and Validity Study on the Patellar Tendon
by Isabel Albarova-Corral, José Segovia-Burillo, Miguel Malo-Urriés, Izarbe Ríos-Asín, Jesús Asín, Jorge Castillo-Mateo, Zeus Gracia-Tabuenca and Mario Morales-Hernández
Diagnostics 2024, 14(11), 1067; https://doi.org/10.3390/diagnostics14111067 - 21 May 2024
Cited by 4 | Viewed by 2101
Abstract
Ultrasound is widely used for tendon assessment due to its safety, affordability, and portability, but its subjective nature poses challenges. This study aimed to develop a new quantitative analysis tool based on artificial intelligence to identify statistical patterns of healthy and pathological tendons. [...] Read more.
Ultrasound is widely used for tendon assessment due to its safety, affordability, and portability, but its subjective nature poses challenges. This study aimed to develop a new quantitative analysis tool based on artificial intelligence to identify statistical patterns of healthy and pathological tendons. Furthermore, we aimed to validate this new tool by comparing it to experts’ subjective assessments. A pilot database including healthy controls and patients with patellar tendinopathy was constructed, involving 14 participants with asymptomatic (n = 7) and symptomatic (n = 7) patellar tendons. Ultrasonographic images were assessed twice, utilizing both the new quantitative tool and the subjective scoring method applied by an expert across five regions of interest. The database contained 61 variables per image. The robustness of the clinical and quantitative assessments was tested via reliability analyses. Lastly, the prediction accuracy of the quantitative features was tested via cross-validated generalized linear mixed-effects logistic regressions. These analyses showed high reliability for quantitative variables related to “Bone” and “Quality”, with ICCs above 0.75. The ICCs for “Edges” and “Thickness” varied but mostly exceeded 0.75. The results of this study show that certain quantitative variables are capable of predicting an expert’s subjective assessment with generally high cross-validated AUC scores. A new quantitative tool for the ultrasonographic assessment of the tendon was designed. This system is shown to be a reliable and valid method for evaluating the patellar tendon structure. Full article
Show Figures

Figure 1

15 pages, 6289 KB  
Article
Automated Foreign Object Detection for Carbon Fiber Laminates Using High-Resolution Ultrasound Testing
by Rifat Ara Nargis, Daniel P. Pulipati and David A. Jack
Materials 2024, 17(10), 2381; https://doi.org/10.3390/ma17102381 - 16 May 2024
Cited by 5 | Viewed by 1663
Abstract
Carbon fiber laminates have become popular in the manufacturing industry for their many desirable properties, like good vibration damping, high strength-to-weight ratio, toughness, high dimensional stability, and low coefficient of thermal expansion. During the manufacturing process, undesirable foreign objects, such as peel-ply strips, [...] Read more.
Carbon fiber laminates have become popular in the manufacturing industry for their many desirable properties, like good vibration damping, high strength-to-weight ratio, toughness, high dimensional stability, and low coefficient of thermal expansion. During the manufacturing process, undesirable foreign objects, such as peel-ply strips, gloving material, and Kapton film, can be introduced into the part which can lead to a localized weakness. These manufacturing defects can function as stress concentration points and oftentimes cause a premature catastrophic failure. In this study, a method using high-resolution pulse-echo ultrasound testing is employed for the detection and quantification of the dimensions of foreign object debris (FOD) embedded within carbon fiber laminates. This research presents a method to create high-resolution C-scans using an out of immersion tank portable housing ultrasound scanning system, with similar capabilities to that of a full immersion system. From the full-waveform dataset, we extract the FOD depth and planar dimensions with an automatic edge detection technique. Results from several carbon fiber laminates are investigated with embedded foreign objects that are often considered undetectable. Results are presented for FOD identification for two different shapes: circles with diameters ranging from 7.62 mm to 12.7 mm, and 3-4-5 triangles with hypotenuses ranging from 7.6 mm to 12.7 mm. CT imaging is used to confirm proper FOD placement and that the FOD was not damaged or altered during manufacturing. Of importance for the ultrasound inspection results, in every single case studied, the FOD is detected, the layer depth is properly identified, and the typical error is less than 1.5 mm for the primary dimension. Full article
(This article belongs to the Special Issue Non-Destructive Testing (NDT) of Advanced Composites and Structures)
Show Figures

Figure 1

Back to TopTop