Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (14)

Search Parameters:
Keywords = pelvic ring 3

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
11 pages, 2118 KB  
Article
Transiliac–Transsacral Screw Provides Good Outcomes for Stabilizing Unstable Fragility Fracture of the Pelvis: A Retrospective Case Series
by Ping-Ying Yu, Kai-Cheng Lin, Yih-Wen Tarng and Chien-Jen Hsu
Life 2026, 16(1), 102; https://doi.org/10.3390/life16010102 - 11 Jan 2026
Viewed by 223
Abstract
(1) Background: Fragility fractures of the pelvis (FFP) in elderly patients pose significant clinical challenges due to osteoporosis and associated morbidity. Transiliac–transsacral (TITS) screw fixation offers biomechanical advantages for stabilizing unstable posterior pelvic ring injuries, yet clinical outcomes remain underreported. We aim to [...] Read more.
(1) Background: Fragility fractures of the pelvis (FFP) in elderly patients pose significant clinical challenges due to osteoporosis and associated morbidity. Transiliac–transsacral (TITS) screw fixation offers biomechanical advantages for stabilizing unstable posterior pelvic ring injuries, yet clinical outcomes remain underreported. We aim to report radiographic and clinical outcomes of TITS fixation for posterior pelvic ring injuries in FFP. (2) Methods: We conducted a retrospective review of 22 elderly female patients (mean age 79.0 ± 7.9 years) who underwent TITS screw fixation for unstable posterior pelvic ring fragility fractures between 2019 and 2024. Perioperative, radiographic, and functional outcomes were analyzed. (3) Results: Median operative time was 74 min (IQR 55–90 min), with minimal blood loss (median 5 mL). No intraoperative neurovascular injuries occurred. Median hospital stay was 7 days (IQR 5–10 days). At a mean follow-up of 6 months, 81.8% of patients maintained excellent or good reduction. Screw loosening was observed in 18.2% of cases, with only one (4.5%) requiring revision. Median VAS scores (range 0–10) decreased significantly from 5 preoperatively to 2 at discharge (p < 0.001). By discharge, 59.1% of patients were able to ambulate with assistance. (4) Conclusion: TITS screw fixation is a safe and feasible option for stabilizing unstable FFP in elderly, osteoporotic patients. It provides reliable mechanical stability, promotes early mobilization, and is associated with a short hospital stay and low complication rates. Full article
(This article belongs to the Special Issue Reconstruction of Bone Defects)
Show Figures

Figure 1

12 pages, 3813 KB  
Article
Bilateral Iliosacral and Transsacral Screws Are Biomechanically Favorable and Reduce the Risk for Fracture Progression in Fragility Fractures of the Pelvis—A Finite Element Analysis
by Moritz F. Lodde, Matthias Klimek, Elmar Herbst, Christian Peez, Oliver Riesenbeck, Michael J. Raschke and Steffen Roßlenbroich
Bioengineering 2025, 12(1), 27; https://doi.org/10.3390/bioengineering12010027 - 1 Jan 2025
Cited by 2 | Viewed by 1686
Abstract
(1) Background: The incidence of fragility fractures of the pelvis (FFP) has increased significantly over the past decades. Unilateral non-displaced fractures, defined as FFP II, are the most common type of fracture. When conservative treatment fails, surgical treatment is indicated. We hypothesize that [...] Read more.
(1) Background: The incidence of fragility fractures of the pelvis (FFP) has increased significantly over the past decades. Unilateral non-displaced fractures, defined as FFP II, are the most common type of fracture. When conservative treatment fails, surgical treatment is indicated. We hypothesize that the use of bilateral SI screws (BSIs) or a transsacral screw (TSI) is superior compared to a unilateral screw (USI) because of a significant reduction in the risk of adjacent fractures and a reduction in fracture progression. (2) Methods: A finite element model of a female pelvic ring was constructed. The ligaments were simulated as tension springs. The load was applied through the sacrum with the pelvis fixed to both acetabula. An FFP IIc was simulated and fixed with either a USI or BSI or TSI. The models were analyzed for a quantitative statement of stress and fracture dislocation. (3) Results: The BSI and TSI resulted in less dislocation compared to the USI. The stress distribution on both sides of the sacrum was favorable in the BSI and TSI groups. The BSI resulted in a higher rotational stability compared to the TSI. (4) Conclusions: The use of either a BSI or TSI for fixation of unilateral FFP is biomechanically favorable compared to the use of a USI. In addition, the use of a BSI or TSI reduces the stress on the contralateral uninjured side of the sacrum. This may reduce the risk of an adjacent fracture or fracture progression. Full article
(This article belongs to the Special Issue Spine Biomechanics)
Show Figures

Figure 1

14 pages, 3474 KB  
Article
Lumbopelvic Stabilization with Two Methods of Triangular Osteosynthesis: A Biomechanical Study
by Niklas Grüneweller, Julia Leunig, Ivan Zderic, Boyko Gueorguiev, Christian Colcuc, Dirk Wähnert and Thomas Vordemvenne
J. Clin. Med. 2024, 13(16), 4744; https://doi.org/10.3390/jcm13164744 - 13 Aug 2024
Cited by 2 | Viewed by 2698
Abstract
(1) Background: Pelvic fractures, and particularly instabilities of the dorsal pelvic ring, are becoming increasingly prevalent, particularly in orthogeriatric patients. Spino-pelvic triangular osteosynthesis is an effective approach to achieve sufficient stabilization in vertically unstable fractures. This study compares two types of osteosynthesis: [...] Read more.
(1) Background: Pelvic fractures, and particularly instabilities of the dorsal pelvic ring, are becoming increasingly prevalent, particularly in orthogeriatric patients. Spino-pelvic triangular osteosynthesis is an effective approach to achieve sufficient stabilization in vertically unstable fractures. This study compares two types of osteosynthesis: the conventional one and a novel instrumentation where the iliosacral screw is placed through a fenestrated iliac screw. (2) Methods: Sixteen artificial osteoporotic L5+pelvis models with an unstable sacral fracture have been instrumented with either an iliac screw connected with a rod to a L5 pedicle screw and an iliosacral screw (TF) or a fenestrated ilium screw connected with a rod to a L5 pedicle screw and an iliosacral screw passing through the fenestra of the iliac screw (TFS). Biomechanical testing was performed using cyclic loading until failure. (3) Results: Both configurations yielded comparable results with regard to initial stiffness, implant loosening, and cycles to failure. The TFS exhibited markedly higher values for cycles to failure and markedly lower values for loosening. However, due to the characteristics of the artificial bone model, these findings were not significant. (4) Conclusions: The novel triangular fixation systems demonstrated comparable results to the standard triangular osteosynthesis configuration. Full article
Show Figures

Figure 1

10 pages, 529 KB  
Article
Long-Term Follow-Up after Iliosacral Screw Fixation of Unstable Pelvic Ring Fractures
by Josef Stolberg-Stolberg, Moritz F. Lodde, Dominik Seiß, Jeanette Köppe, René Hartensuer, Michael J. Raschke and Oliver Riesenbeck
J. Clin. Med. 2024, 13(4), 1070; https://doi.org/10.3390/jcm13041070 - 14 Feb 2024
Cited by 5 | Viewed by 2164
Abstract
(1) Background: High-energy injuries of the pelvic ring are rare. The wide application of iliosacral screw fixation of the posterior pelvic ring is relatively new. The aim of the present study was to evaluate the long-term quality of life. (2) Methods: All patients [...] Read more.
(1) Background: High-energy injuries of the pelvic ring are rare. The wide application of iliosacral screw fixation of the posterior pelvic ring is relatively new. The aim of the present study was to evaluate the long-term quality of life. (2) Methods: All patients treated with an iliosacral screw for a posterior pelvic ring stabilization after high-energy trauma at a level 1 trauma center between 2005 and 2015 were included. Pelvic ring injuries were classified according to the Tile classification adapted by AO/ASIF. The clinical evaluation included the patient-oriented questionnaires surveys of the Majeed Score, Iowa Pelvic Score (IPS), Work Ability Index (WAI), SF-36, EQ5D-5L. (3) Results: A total of 84 patients were included with a median follow-up of 130.1 months (IQR 95.0–162.0 months). The median ISS was 22.5 (IQR 16.0–29.0), mean Majeed Score 83.32 (SD ± 19.26), IPS 77.88 (SD ± 13.96), WAI 32.71 (SD ± 11.31), SF-36 PF 71.25 (SD ± 29.61) and EQ5D-5L 0.83 (SD ± 0.21). There was a notably difference between uni- and bilateral pelvic fractures (p = 0.033) as well as a correlation with the ISS (p = 0.043) with inferior functional outcome measured by IPS. (4) Conclusions: Long-term follow-up of iliosacral screw fixation of unstable pelvic ring fractures showed a good quality of life and functional outcome with equal EQ5D-5L results and inferior SF-36 physical functioning compared to the German population. Full article
(This article belongs to the Special Issue Clinical Treatment and Management of Orthopedic Trauma)
Show Figures

Figure 1

12 pages, 9256 KB  
Article
Stabilization of Traumatic Iliosacral Instability Using Innovative Implants: A Biomechanical Comparison
by Niklas Grüneweller, Julia Leunig, Ivan Zderic, Boyko Gueorguiev, Dirk Wähnert and Thomas Vordemvenne
J. Clin. Med. 2024, 13(1), 194; https://doi.org/10.3390/jcm13010194 - 29 Dec 2023
Cited by 3 | Viewed by 1659
Abstract
(1) Background: Demographic changes over the past decade have had a significant impact on pelvic ring fractures. They have increased dramatically in the orthogeriatric population. Surgeons are faced with implant fixation issues in the treatment of these fragility fractures. This study compares two [...] Read more.
(1) Background: Demographic changes over the past decade have had a significant impact on pelvic ring fractures. They have increased dramatically in the orthogeriatric population. Surgeons are faced with implant fixation issues in the treatment of these fragility fractures. This study compares two innovative implants for stabilizing the iliosacral joint in a biomechanical setting. (2) Methods: An iliosacral screw with a preassembled plate allowing the placement of an additional short, angular stable screw in the ilium and a triangular fixation system consisting of a fenestrated ilium screw and an iliosacral screw quasi-statically inserted through the “fenestra” were instrumented in osteoporotic artificial bone models with a simulated Denis zone 1 fracture. Biomechanical testing was performed on a servo-hydraulic testing machine using increasing, synchronous axial and torsional sinusoidal cyclic loading to failure. (3) Results: The SI-Plate and TriFix showed comparable stiffness values. The values for fracture gap angle and screw tip cutout were significantly lower for the TriFix compared to the SI-Plate. In addition, the number of cycles to failure was significantly higher for the TriFix. (4) Conclusions: Implant anchorage and primary stability can be improved in iliosacral instability using the triangular stabilization system. Full article
(This article belongs to the Special Issue Advances in Trauma and Orthopedic Surgery)
Show Figures

Figure 1

9 pages, 1619 KB  
Article
Bony Sacral Volume after Sacro-Iliac Screw Fixation of Pelvic Fractures Is Dependent on Reduction of the Anterior Pelvic Ring
by Florian Baumann, Stefano Pagano, Volker Alt and Viola Freigang
J. Clin. Med. 2023, 12(12), 4169; https://doi.org/10.3390/jcm12124169 - 20 Jun 2023
Cited by 2 | Viewed by 1582
Abstract
Pelvic ring injuries are uncommon but serious injuries. Percutaneous sacro-iliac screw fixation (SSF) is the standard treatment for posterior stabilization of pelvic fractures. Compression forces of the SSF might cause deformity of the sacrum and the pelvic ring. The aim of this radio-volumetric [...] Read more.
Pelvic ring injuries are uncommon but serious injuries. Percutaneous sacro-iliac screw fixation (SSF) is the standard treatment for posterior stabilization of pelvic fractures. Compression forces of the SSF might cause deformity of the sacrum and the pelvic ring. The aim of this radio-volumetric study is to evaluate the morphometry of the sacrum and pelvic ring in SSF for posterior pelvic fractures. (1) Methods: We conducted a radio-volumetric study measuring the bony sacral volume before and after SSF for a pelvic fracture based on a three-dimensional reconstruction of the pre- and postoperative computed tomography scan of 19 patients with a C-type pelvic fracture. In addition to the bony sacral volume, we assessed the pelvic deformity and the load bearing axis. We compared the results of patients without anterior stabilization (Group A) to patients who had additional ORIF of the anterior pelvic ring. (2) Results: Median age of the patients was 41.2 years (±17.8). All patients received percutaneous SSF with partially threaded 7.3 mm screws. The sacral volume decreased from 202.9 to 194.3 cm3 in group A (non-operative treatment anterior, n = 10) and an increase of sacral volume from 229.8 to 250.4 cm3 in group B (anterior ORIF; n = 9). Evaluation of the pelvic deformity also reflected this trend by a decrease of the ipsilateral load-bearing angle in group A (37.0° to 36.4°) and an increase of this angle in group B (36.3 to 39.9°). (3) Conclusions: Bony sacral volume and pelvic deformity after sacro-iliac screw fixation in pelvic fractures depend on treatment of the anterior pelvic ring. Reduction and fixation of the anterior fracture shows an increase of the bony sacral volume and the load bearing angle leading to a closer to normal reconstruction of the pelvic anatomy. Full article
Show Figures

Figure 1

8 pages, 1264 KB  
Review
Pelvic Malunion: A Systematic Review, Dichotomy of Definitions and Treatment
by Sasha Stine, Austen Washington, Ramesh Kumar Sen, Kerellos Nasr and Rahul Vaidya
Medicina 2022, 58(8), 1098; https://doi.org/10.3390/medicina58081098 - 14 Aug 2022
Cited by 10 | Viewed by 3529
Abstract
Background and Objectives: Pelvic nonunion and malunion have been documented as rare complications in pelvic fractures and literature describing these topics is severely limited. Articles dedicated solely to pelvic malunion are nearly nonexistent. We conducted a literature search with the goal of [...] Read more.
Background and Objectives: Pelvic nonunion and malunion have been documented as rare complications in pelvic fractures and literature describing these topics is severely limited. Articles dedicated solely to pelvic malunion are nearly nonexistent. We conducted a literature search with the goal of providing a summary of the definition, causes, treatment strategies, and outcomes of pelvic malunion correction. Materials and Methods: An initial review of the literature was performed using the PubMed, ScienceDirect, and Cochrane Database of Systematic Reviews databases. Search terms used were “malunion” AND “pelvic” OR “pelvis”. Duplicate articles, non-English language articles without translations available and non-human subject studies were excluded. Results: Eleven original publications were found describing experiences with pelvic malunion. Seven of the articles were exclusively dedicated to the topic of pelvic fracture malunion, and only two reported on a series of patients treated for malunion with variably staged procedures. Most reports define pelvic pain as the main indication for surgical correction, along with gait disturbance, standing or sitting imbalance, and urinary or sexual dysfunction. Radiographically, vertical displacement of one to two centimeters and rotation of the hemipelvis of fifteen degrees or more have been described in defining malunion. No treatment algorithms exist, and each patient is treated with a unique work-up and operative plan due to the complexity of the problem. Only one series reported a patient satisfaction rate of 75% following malunion treatment. Conclusions: Pelvic malunion is a rare complication of pelvic ring injury and is seldom discussed in the literature. We found two small case series reporting exclusively on malunion treatment and complications. While some of the combination studies made the distinction in the diagnosis of malunion and nonunion, they rarely differentiated the treatment outcomes between the two categories. This paper describes pelvic malunion and highlights the need for more research into surgical outcomes of treatment specifically regarding functionality, patient satisfaction, and recurrence of preoperative symptoms. Full article
(This article belongs to the Special Issue Malunion of Fractures of the Lower Extremity)
Show Figures

Figure 1

11 pages, 16016 KB  
Article
Sacroiliac Screw Placement with Ease: CT-Guided Pelvic Fracture Osteosynthesis in the Elderly
by Hannah Kress, Roman Klein, Tim Pohlemann and Christoph Georg Wölfl
Medicina 2022, 58(6), 809; https://doi.org/10.3390/medicina58060809 - 15 Jun 2022
Cited by 5 | Viewed by 3075
Abstract
Background and Objectives: The number of geriatric patients presenting with fragility fractures of the pelvis is increasing due to ageing Western societies. There are nonoperative and several operative treatment approaches. Many of which cause prolonged hospitalisation, so patients become bedridden and lose [...] Read more.
Background and Objectives: The number of geriatric patients presenting with fragility fractures of the pelvis is increasing due to ageing Western societies. There are nonoperative and several operative treatment approaches. Many of which cause prolonged hospitalisation, so patients become bedridden and lose mobility and independence. This retrospective study evaluates the postoperative outcome of a computed tomography-guided (CT-guided) minimally invasive approach of sacroiliac screw osteosynthesis. The particular focus is to demonstrate its ease of use, feasibility with the equipment of virtually every hospital and beneficial outcomes to the patients. Materials and Methods: 28 patients (3 men, 25 women, age 80.5 ± 6.54 years) with fragility fractures of the pelvis types II-IV presenting between August 2015 and September 2021 were retrospectively reviewed. The operation was performed using the CT of the radiology department for intraoperative visualization of screw placement. Patients only received screw osteosynthesis of the posterior pelvic ring and cannulated screws underwent cement augmentation. Outcomes measured included demographic data, fracture type, postoperative parameters and complications encountered. The quality of life (QoL) was assessed using the German version of the EQ-5D-3L. Results: The average operation time was 32.4 ± 9.6 min for the unilateral and 50.7 ± 17.4 for the bilateral procedure. There was no significant difference between surgeons operating (p = 0.12). The postoperative CT scans were used to evaluate the outcome and showed only one case of penetration (by 1 mm) of the ventral cortex, which did not require operative revision. No case of major complication was reported. Following surgery, patients were discharged after a median of 4 days (Interquartile range 3–7.5). 53.4% of the patients were discharged home or to rehabilitation. The average score on the visual analogue scale of the EQ-5D-3L evaluating the overall wellbeing was 55.6 (Interquartile range (IQR) 0–60). Conclusions: This study shows that the operative method is safe to use in daily practice, is readily available and causes few complications. It permits immediate postoperative mobilization and adequate pain control. Independence and good quality of life are preserved. Full article
(This article belongs to the Special Issue Treatment of Spine and Pelvic Fractures in Patients with Osteoporosis)
Show Figures

Figure 1

12 pages, 29695 KB  
Article
Does Cement Augmentation of the Sacroiliac Screw Lead to Superior Biomechanical Results for Fixation of the Posterior Pelvic Ring? A Biomechanical Study
by Moritz F. Lodde, J. Christoph Katthagen, Clemens O. Schopper, Ivan Zderic, R. Geoff Richards, Boyko Gueorguiev, Michael J. Raschke and René Hartensuer
Medicina 2021, 57(12), 1368; https://doi.org/10.3390/medicina57121368 - 16 Dec 2021
Cited by 15 | Viewed by 5438
Abstract
Background and Objectives: The stability of the pelvic ring mainly depends on the integrity of its posterior part. Percutaneous sacroiliac (SI) screws are widely implanted as standard of care treatment. The main risk factors for their fixation failure are related to vertical [...] Read more.
Background and Objectives: The stability of the pelvic ring mainly depends on the integrity of its posterior part. Percutaneous sacroiliac (SI) screws are widely implanted as standard of care treatment. The main risk factors for their fixation failure are related to vertical shear or transforaminal sacral fractures. The aim of this study was to compare the biomechanical performance of fixations using one (Group 1) or two (Group 2) standard SI screws versus one SI screw with bone cement augmentation (Group 3). Materials and Methods: Unstable fractures of the pelvic ring (AO/OTA 61-C1.3, FFP IIc) were simulated in 21 artificial pelvises by means of vertical osteotomies in the ipsilateral anterior and posterior pelvic ring. A supra-acetabular external fixator was applied to address the anterior fracture. All specimens were tested under progressively increasing cyclic loading until failure, with monitoring by means of motion tracking. Fracture site displacement and cycles to failure were evaluated. Results: Fracture displacement after 500 cycles was lowest in Group 3 (0.76 cm [0.30] (median [interquartile range, IQR])) followed by Group 1 (1.42 cm, [0.21]) and Group 2 (1.42 cm [1.66]), with significant differences between Groups 1 and 3, p = 0.04. Fracture displacement after 1000 cycles was significantly lower in Group 3 (1.15 cm [0.37]) compared to both Group 1 (2.19 cm [2.39]) and Group 2 (2.23 cm [3.65]), p ≤ 0.04. Cycles to failure (Group 1: 3930 ± 890 (mean ± standard deviation), Group 2: 3676 ± 348, Group 3: 3764 ± 645) did not differ significantly between the groups, p = 0.79. Conclusions: In our biomechanical setup cement augmentation of one SI screw resulted in significantly less displacement compared to the use of one or two SI screws. However, the number of cycles to failure was not significantly different between the groups. Cement augmentation of one SI screw seems to be a useful treatment option for posterior pelvic ring fixation, especially in osteoporotic bone. Full article
(This article belongs to the Special Issue Treatment of Spine and Pelvic Fractures in Patients with Osteoporosis)
Show Figures

Figure 1

14 pages, 2886 KB  
Article
Are Sarcopenia and Myosteatosis in Elderly Patients with Pelvic Ring Injury Related to Mortality, Physical Functioning and Quality of Life?
by Hester Banierink, Julia J. C. Bombach, Kaj ten Duis, Frank F. A. IJpma, Erik Heineman, Sven H. van Helden, Robert J. Nijveldt, Alain R. Viddeleer and Inge H. F. Reininga
J. Clin. Med. 2021, 10(21), 4874; https://doi.org/10.3390/jcm10214874 - 22 Oct 2021
Cited by 3 | Viewed by 2496
Abstract
The purpose of this study was to evaluate the prevalence of sarcopenia and/or myosteatosis in elderly patients with pelvic ring injuries and their influence on mortality, patient-perceived physical functioning and quality of life (QoL). A multicenter retrospective cohort study was conducted including elderly [...] Read more.
The purpose of this study was to evaluate the prevalence of sarcopenia and/or myosteatosis in elderly patients with pelvic ring injuries and their influence on mortality, patient-perceived physical functioning and quality of life (QoL). A multicenter retrospective cohort study was conducted including elderly patients aged ≥ 65 treated for a pelvic ring injury. Cross-sectional computed tomography (CT) muscle measurements were obtained to determine the presence of sarcopenia and/or myosteatosis. Kaplan–Meier analysis was used for survival analysis, and Cox proportional hazards regression analysis was used to determine risk factors for mortality. Patient-reported outcome measures for physical functioning (SMFA) and QoL (EQ-5D) were used. Multivariable linear regression analyses were used to determine the effect of sarcopenia and myosteatosis on patient-perceived physical functioning and QoL. Data to determine sarcopenia and myosteatosis were available for 199 patients, with a mean follow-up of 2.4 ± 2.2 years: 66 patients (33%) were diagnosed with sarcopenia and 65 (32%) with myosteatosis, while 30 of them (15%) had both. Mortality rates in patients at 1 and 3 years without sarcopenia and myosteatosis were 13% and 21%, compared to 11% and 36% in patients with sarcopenia, 17% and 31% in patients with myosteatosis and 27% and 43% in patients with both. Higher age at the time of injury and a higher Charlson Comorbidity Index (CCI) were independent risk factors for mortality. Patient-reported mental and emotional problems were significantly increased in patients with sarcopenia. Full article
(This article belongs to the Collection Pelvic Instability: Currents Insights)
Show Figures

Figure 1

15 pages, 1697 KB  
Review
Does 3D-Assisted Operative Treatment of Pelvic Ring Injuries Improve Patient Outcome?—A Systematic Review of the Literature
by Hester Banierink, Anne M. L. Meesters, Kaj ten Duis, Job N. Doornberg, Mostafa El Moumni, Erik Heineman, Inge H. F. Reininga and Frank F. A. IJpma
J. Pers. Med. 2021, 11(9), 930; https://doi.org/10.3390/jpm11090930 - 18 Sep 2021
Cited by 13 | Viewed by 3113
Abstract
Background: There has been an exponential growth in the use of advanced technologies for three-dimensional (3D) virtual pre- and intra-operative planning of pelvic ring injury surgery but potential benefits remain unclear. The purpose of this study was to evaluate differences in intra- and [...] Read more.
Background: There has been an exponential growth in the use of advanced technologies for three-dimensional (3D) virtual pre- and intra-operative planning of pelvic ring injury surgery but potential benefits remain unclear. The purpose of this study was to evaluate differences in intra- and post-operative results between 3D and conventional (2D) surgery. Methods: A systematic review was performed including published studies between 1 January 2010 and 22 May 2020 on all available 3D techniques in pelvic ring injury surgery. Studies were assessed for their methodological quality according to the Modified McMaster Critical Review form. Differences in operation time, blood loss, fluoroscopy time, screw malposition rate, fracture reduction and functional outcome between 3D-assisted and conventional (2D) pelvic injury treatment were evaluated and a best-evidence synthesis was performed. Results: Eighteen studies fulfilled the inclusion criteria, evaluating a total of 988 patients. Overall quality was moderate. Regarding intra-operative results of 3D-assisted versus conventional surgery: The weighted mean operation time per screw was 43 min versus 52 min; for overall operation time 126 min versus 141 min; blood loss 275 ± 197 mL versus 549 ± 404 mL; fluoroscopy time 74 s versus 125 s and fluoroscopy frequency 29 ± 4 versus 63 ± 3. In terms of post-operative outcomes of 3D-assisted versus conventional surgery: weighted mean screw malposition rate was 8% versus 18%; quality of fracture reduction measured by the total excellent/good rate by Matta was 86% versus 82% and Majeed excellent/good rate 88% versus 83%. Conclusion: The 3D-assisted surgery technologies seem to have a positive effect on operation time, blood loss, fluoroscopy dose, time and frequency as well as accuracy of screw placement. No improvement in clinical outcome in terms of fracture reduction and functional outcome has been established so far. Due to a wide range of methodological quality and heterogeneity between the included studies, results should be interpreted with caution. Full article
Show Figures

Figure 1

7 pages, 549 KB  
Article
Cross-Cultural Adaptation and Psychometric Properties of the Lithuanian Version of the Majeed Pelvic Score
by Giedrius Petryla, Rokas Bobina, Sigitas Ryliškis, Valentinas Uvarovas, Jaunius Kurtinaitis, Tomas Sveikata, Giedrius Kvederas and Igoris Šatkauskas
Medicina 2021, 57(5), 417; https://doi.org/10.3390/medicina57050417 - 25 Apr 2021
Cited by 2 | Viewed by 2379
Abstract
Background and Objectives: There are no valid patient-based pelvic ring function assessment tools in Lithuania. The most widely used instrument is the Majeed Pelvic Score (MPS), which is proven to be an effective tool for assessing pelvic function after pelvic injuries. The [...] Read more.
Background and Objectives: There are no valid patient-based pelvic ring function assessment tools in Lithuania. The most widely used instrument is the Majeed Pelvic Score (MPS), which is proven to be an effective tool for assessing pelvic function after pelvic injuries. The aims of our study were: (1) the translation and cross-cultural adaptation of the MPS for the Lithuanian-speaking population, (2) to test the psychometric properties of the Lithuanian version of the MPS (MPS-LT) at follow-up two-time points after pelvic fractures. Materials and Methods: The MPS was translated and culturally adapted. Psychometric properties of the MPS-LT were determined in one patient group (n = 40) at two time-points during follow-up examination from 1.5 to 3 months (mean 2 months) and from 11 to 20 months (mean 12 months). Results: At the mean time of 2 months after trauma, Cronbach’s α of the MPS-LT was 0.65. Correlation of the MPS-LT with the Iowa Pelvic Score (IPS) was r = 0.84 (p < 0.001), and with the Lithuanian SF-36, PCS was r = 0.53 (p < 0.001). At the mean time follow-up of 12 months, Cronbach’s α was 0.86, correlation with the IPS was r = 0.92 (p < 0.001), and with the Lithuanian SF-36, PCS – r = 0.82 (p < 0.001). At the 2-month follow-up, neither floor nor ceiling effects were reached, but at 12 months, 27.5% of patients reached the ceiling effect, while none reached the floor effect. The effect size of the MPS-LT was 1.66. Conclusions: The MPS-LT has limited ability to measure functional outcomes at 2 months after pelvic fracture. In contrast, at the 12-month follow-up examination, the MPS-LT had a good ability to assess pelvic function, and it was sensitive to health changes. The MPS-LT can be used as a pelvic function assessment tool after pelvic fractures for the Lithuanian-speaking population. Full article
(This article belongs to the Section Surgery)
Show Figures

Figure 1

9 pages, 560 KB  
Article
Comparison of One-Year Functional Outcomes and Quality of Life between Posterior Pelvic Ring Fixation and Combined Anterior-Posterior Pelvic Ring Fixation after Lateral Compression (B2 Type) Pelvic Fracture
by Giedrius Petryla, Valentinas Uvarovas, Rokas Bobina, Jaunius Kurtinaitis, Roma Puronaitė, Giedrius Kvederas and Igoris Šatkauskas
Medicina 2021, 57(3), 204; https://doi.org/10.3390/medicina57030204 - 26 Feb 2021
Cited by 20 | Viewed by 2796
Abstract
Background and Objectives: The treatment algorithm of lateral compression B2 type pelvic fractures are still under debate. Some authors advocate conservative treatment, while others recommend surgical approach. The clear indications for isolated anterior or posterior ring fixation or combined anterior-posterior pelvic ring [...] Read more.
Background and Objectives: The treatment algorithm of lateral compression B2 type pelvic fractures are still under debate. Some authors advocate conservative treatment, while others recommend surgical approach. The clear indications for isolated anterior or posterior ring fixation or combined anterior-posterior pelvic ring fixation of B2 type fractures remain unclear. The aim of this study was to compare the functional outcomes and quality of life after isolated posterior pelvic ring fixation and combined anterior-posterior pelvic ring fixation for the treatment of B2 pelvic fractures. Materials and Methods: Patients aged 18 to 65 years with B2 type pelvic fracture hospitalized in a single trauma centre over a period of 3 years were included in the research. Based on the attending surgeon’s preference, patients were treated with isolated posterior or combined anterior-posterior pelvic fixation. The quality of life and pelvic function were assessed using SF-36 and Majeed questionnaires, respectively. Patients filled in the questionnaires twice: during the first hospitalization (concerning their pre-trauma state—timepoint I) and one-year after the injury (timepoint II). Results: A cohort of 32 patients with B2 type pelvic fracture was enrolled in the analysis: 23 (72%) were female and 9 (28%) were male. The mean age was 35.3 ± 11.9 years. In this cohort 13 (41%) patients underwent isolated posterior pelvic ring fixation (group I) and 19 (59%) patients underwent combined anterior-posterior pelvic ring fixation (group II). No statistically significant differences were observed between the groups in both timepoints concerning Majeed, SF-36 PCS and MCS scores. However, in both groups Majeed and SF-36 PCS scores were statistically significantly lower one year after pelvic fracture compared with pre-trauma state, while SF-36 MCS scores did not differ. Conclusions: No differences were found in quality of life and functional outcomes between isolated posterior pelvic ring fixation and combined anterior-posterior fixation for the treatment of B2 type pelvic fractures. Full article
(This article belongs to the Section Surgery)
Show Figures

Figure 1

11 pages, 1474 KB  
Article
Isolated Pubic Ramus Fractures Are Serious Adverse Events for Elderly Persons: An Observational Study on 138 Patients with Fragility Fractures of the Pelvis Type I (FFP Type I)
by Pol Maria Rommens, Johannes Christof Hopf, Michiel Herteleer, Benjamin Devlieger, Alexander Hofmann and Daniel Wagner
J. Clin. Med. 2020, 9(8), 2498; https://doi.org/10.3390/jcm9082498 - 3 Aug 2020
Cited by 34 | Viewed by 6664
Abstract
Background: Fractures of the pubic ramus without involvement of the posterior pelvic ring represent a minority of fragility fractures of the pelvis (FFP). The natural history of patients suffering this FFP Type I has not been described so far. Material and methods: All [...] Read more.
Background: Fractures of the pubic ramus without involvement of the posterior pelvic ring represent a minority of fragility fractures of the pelvis (FFP). The natural history of patients suffering this FFP Type I has not been described so far. Material and methods: All patients, who were admitted with isolated pubic ramus fractures between 2007 and mid-2018, have been reviewed. Epidemiologic data, comorbidities, in-hospital complications, and one-year mortality were recorded. Of all surviving patients, living condition before the fracture and at follow-up was noted. Mobility was scored with the Parker Mobility Score, quality of life with the European Quality of Life 5 Dimensions 3 Level (EQ-5D-3L), subjective sensation of pain with the Numeric Rating Scale (NRS). Results: A consecutive series of 138 patients was included in the study. There were 117 women (84.8%) and 21 men (15.2%). Mean age was 80.6 years (SD 8.6 years). 89.1% of patients presented with comorbidities, 81.2% of them had cardiovascular diseases. Five patients (4%) died during hospital-stay. Median in-hospital stay was eight days (2–45 days). There were in-hospital complications in 16.5%, urinary tract infections, and pneumonia being the most frequent. One-year mortality was 16.7%. Reference values for the normal population of the same age are 5.9% for men and 4.0% for women. One-year mortality rate was 22.2% in the patient group of 80 years or above and 8.8% in the patient group below the age of 80. The rate of surviving patients living at home with or without assistance dropped from 80.5% to 65.3%. The median EQ-5D-Index Value was 0.62 (0.04–1; IQR 0.5–0.78). Reference value for the normal population is 0.78. Average PMS was 4 and NRS 3. Within a two-year period, additional fragility fractures occurred in 21.2% and antiresorptive medication was taken by only 45.2% of patients. Conclusion. Pubic ramus fractures without involvement of the posterior pelvis (FFP Type I) are serious adverse events for elderly persons. During follow-up, there is an excess mortality, a loss of independence, a restricted mobility, and a decreased quality of life. Pubic ramus fractures are indicators for the need to optimize the patient’s general condition. Full article
Show Figures

Figure 1

Back to TopTop