Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (55)

Search Parameters:
Keywords = pedicle screw accuracy

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
10 pages, 997 KiB  
Article
Does Malpositioning of Pedicle Screws Affect Biomechanical Stability in a Novel Quasistatic Test Setup?
by Stefan Schleifenbaum, Florian Metzner, Janine Schultze, Sascha Kurz, Christoph-Eckhard Heyde and Philipp Pieroh
Bioengineering 2025, 12(7), 781; https://doi.org/10.3390/bioengineering12070781 - 18 Jul 2025
Viewed by 403
Abstract
Pedicle screw fixation is a common spinal surgery technique, but concerns remain about stability when screws are malpositioned. Traditional in vitro pull-out tests assess anchorage but lack physiological accuracy. This study examined the stability of correctly placed and intentionally malpositioned pedicle screws on [...] Read more.
Pedicle screw fixation is a common spinal surgery technique, but concerns remain about stability when screws are malpositioned. Traditional in vitro pull-out tests assess anchorage but lack physiological accuracy. This study examined the stability of correctly placed and intentionally malpositioned pedicle screws on forty vertebrae from five cadavers. Optimal screw paths were planned via CT scans and applied using 3D-printed guides. Four malposition types—medial, lateral, superior, and superior-lateral—were created by shifting the original trajectory. A custom setup applied three consecutive cycles of tensile and compressive load from 50 N to 200 N. Screw inclination under load was measured with a 3D optical system. The results showed increasing screw inclination with higher forces, reaching about 1° at 50 N and 2° at 100 N, similar in both load directions. Significant differences in inclination were only found at 100 N tensile load, where malpositioned screws showed a lower inclination. Overall, malpositioning had no major effect on screw loosening. These findings suggest that minor deviations in screw placement do not significantly compromise mechanical stability. Clinically, the main concern with malpositioning lies in the potential for injury to nearby structures rather than reduced screw fixation strength. Full article
(This article belongs to the Special Issue Spine Biomechanics)
Show Figures

Figure 1

9 pages, 1077 KiB  
Article
Concave Side of Proximal Thoracic Zone Vulnerable to Pedicle Screw Perforation in Adolescent Idiopathic Scoliosis Surgery: Comparative Analysis of Pre- and Intraoperative Computed Tomography Navigation
by Tomohiro Yamada, Yu Yamato, Tomohiko Hasegawa, Go Yoshida, Tomohiro Banno, Hideyuki Arima, Shin Oe, Koichiro Ide, Kenta Kurosu and Yukihiro Matsuyama
J. Clin. Med. 2025, 14(13), 4729; https://doi.org/10.3390/jcm14134729 - 3 Jul 2025
Viewed by 389
Abstract
Background: The aim of this study was to assess pedicle screw (PS) accuracy and identify perforation patterns using computed tomography (CT) navigation in adolescent idiopathic scoliosis (AIS) surgery. Methods: A total of 107 AIS patients were retrospectively reviewed. Preoperative CT navigation was used [...] Read more.
Background: The aim of this study was to assess pedicle screw (PS) accuracy and identify perforation patterns using computed tomography (CT) navigation in adolescent idiopathic scoliosis (AIS) surgery. Methods: A total of 107 AIS patients were retrospectively reviewed. Preoperative CT navigation was used in 48 patients (853 screws), and intraoperative CT with a second 3D scan was used in 59 patients (1059 screws). Postoperative CT images were analyzed using the Rampersaud grading system. Results: Overall PS accuracy (grade A + B) was significantly higher in the intraoperative CT group than the preoperative group (97% vs. 95%, p = 0.008). In Lenke type 1 cases, accuracy was also higher in the intraoperative group (97.8% vs. 95.1%, p = 0.014). Grade D perforations were most frequent on the concave side of the proximal thoracic (PT) zone in both groups. Ten screws were re-inserted during surgery in the intraoperative group based on findings from the second 3D scan. Conclusions: The concave PT zone is a common site for PS misplacement. Intraoperative CT navigation with a second 3D scan enhances PS accuracy compared with preoperative CT navigation. Full article
(This article belongs to the Section Orthopedics)
Show Figures

Figure 1

11 pages, 1902 KiB  
Communication
Innovative Pedicle Screw Insertion with Mixed Reality Technology Improves Insertion Accuracy in Spinal Surgery
by Shintaro Obata, Akira Shinohara, Daigo Arimura, Shunsuke Katsumi, Hiroki Wakiya and Mitsuru Saito
Sensors 2025, 25(13), 3939; https://doi.org/10.3390/s25133939 - 24 Jun 2025
Viewed by 1283
Abstract
The accuracy of pedicle screw insertion in pediatric scoliosis correction surgery using augmented reality technology in combination with a conventional navigation system was evaluated, and its usefulness was verified. A retrospective study of patients who underwent mixed reality technology-assisted posterior scoliosis correction and [...] Read more.
The accuracy of pedicle screw insertion in pediatric scoliosis correction surgery using augmented reality technology in combination with a conventional navigation system was evaluated, and its usefulness was verified. A retrospective study of patients who underwent mixed reality technology-assisted posterior scoliosis correction and fixation was conducted. In total, 361 pedicle screws inserted with a mixed reality technology-assisted navigation system were analyzed; 25 pedicle screws (6.9%) showed Rao Classification Grade 1 deviation, whereas 0.83% showed Rao Classification Grade 2.3 deviation, which is a clinical deviation. In terms of the relationship between the rotation of the vertebral body and the deviation of the pedicle screw, the pedicle screw tended to deviate more easily when it was necessary to insert the pedicle screw in a more strongly oblique position due to the rotation of the vertebral body. The results suggest that the pedicle screw insertion accuracy with augmented reality technology may be superior to that with conventional navigation alone in scoliosis correction and fusion surgery for scoliosis in children. This system is expected to become a standard support tool for spine surgery and will contribute to improving the success rate of surgery and reducing the burden on the surgeon. Full article
(This article belongs to the Section Biomedical Sensors)
Show Figures

Figure 1

30 pages, 8572 KiB  
Article
Robotic-Guided Spine Surgery: Implementation of a System in Routine Clinical Practice—An Update
by Mirza Pojskić, Miriam Bopp, Omar Alwakaa, Christopher Nimsky and Benjamin Saß
J. Clin. Med. 2025, 14(13), 4463; https://doi.org/10.3390/jcm14134463 - 23 Jun 2025
Viewed by 693
Abstract
Objective: The aim of this study is to present the initiation of robotic-guided (RG) spine surgery into routine clinical care at a single center with the use of intraoperative CT (iCT) automatic registration-based navigation. The workflow included iCT with automatic registration, fusion with [...] Read more.
Objective: The aim of this study is to present the initiation of robotic-guided (RG) spine surgery into routine clinical care at a single center with the use of intraoperative CT (iCT) automatic registration-based navigation. The workflow included iCT with automatic registration, fusion with preoperative imaging, verification of preplanned screw trajectories, RG introduction of K-wires, and the insertion of pedicle screws (PSs), followed by a control iCT scan. Methods: All patients who underwent RG implantation of pedicle screws using the Cirq® robotic arm (BrainLab, Munich, Germany) in the thoracolumbar spine at our department were included in the study. The accuracy of the pedicles screws was assessed using the Gertzbein–Robbins scale (GRS). Results: In total, 108 patients (60 female, mean age 68.7 ± 11.4 years) in 109 surgeries underwent RG PS placement. Indications included degenerative spinal disorders (n = 30 patients), spondylodiscitis (n = 24), tumor (n = 33), and fracture (n = 22), with a mean follow-up period of 7.7 ± 9 months. Thirty-seven cases (33.9%) were performed percutaneously, and all others were performed openly. Thirty-three operations were performed on the thoracic spine, forty-four on the lumbar and lumbosacral spine, thirty on the thoracolumbar, one on the cervicothoracic spine, and one on the thoracolumbosacral spine. The screws were inserted using a fluoroscopic (first 12 operations) or navigated technique (latter operations). The mean operation time was 228.8 ± 106 min, and the mean robotic time was 31.5 ± 18.4 min. The mean time per K-wire was 5.35 ± 3.98 min. The operation time was lower in the percutaneous group, while the robot time did not differ between the two groups. Robot time and the time per K-wire improved over time. Out of 688 screws, 592 were GRS A screws (86.1%), 54 B (7.8%), 22 C (3.2%), 12 D (1.7%), and 8 E (1.2%). Seven screws were revised intraoperatively, and after revision, all were GRS A. E screws were either revised or removed. In the case of D screws, screws located at the end of the construct were revised, while so-called in-out-in screws in the middle of the construct were not revised. Conclusions: Brainlab’s Cirq® Robotic Alignment Module feature enables placement of pedicle screws in the thoracolumbar spine with high accuracy. A learning curve is shown through improvements in robotic time and time per K-wire. Full article
(This article belongs to the Special Issue Spine Surgery: Clinical Advances and Future Directions)
Show Figures

Figure 1

11 pages, 1079 KiB  
Technical Note
Visuohaptic Feedback in Robotic-Assisted Spine Surgery for Pedicle Screw Placement
by Giuseppe Loggia, Fedan Avrumova and Darren R. Lebl
J. Clin. Med. 2025, 14(11), 3804; https://doi.org/10.3390/jcm14113804 - 29 May 2025
Viewed by 651
Abstract
Introduction: Robotic-assisted (RA) spine surgery enhances pedicle screw placement accuracy through real-time navigation and trajectory guidance. However, the absence of traditional direct haptic feedback by freehand instrumentation remains a concern for some, particularly in minimally invasive (MIS) procedures where direct visual confirmation [...] Read more.
Introduction: Robotic-assisted (RA) spine surgery enhances pedicle screw placement accuracy through real-time navigation and trajectory guidance. However, the absence of traditional direct haptic feedback by freehand instrumentation remains a concern for some, particularly in minimally invasive (MIS) procedures where direct visual confirmation is limited. During RA spine surgery, navigation systems display three-dimensional data, but factors such as registration errors, intraoperative motion, and anatomical variability may compromise accuracy. This technical note describes a visuohaptic intraoperative phenomenon observed during RA spine surgery, its underlying mechanical principles, and its utility. During pedicle screw insertion with a slow-speed automated drill in RA spine procedures, a subtle and rhythmic variation in resistance has been observed both visually on the navigation interface and haptically through the handheld drill. This intraoperative pattern is referred to in this report as a cyclical insertional torque (CIT) pattern and has been noted across multiple cases. The CIT pattern is hypothesized to result from localized stick–slip dynamics, where alternating phases of resistance and release at the bone–screw interface generate periodic torque fluctuations. The pattern is most pronounced at low insertion speeds and diminishes with increasing drill velocity. CIT is a newly described intraoperative observation that may provide visuohaptic feedback during pedicle screw insertion in RA spine surgery. Through slow-speed automated drilling, CIT offers a cue for bone engagement, which could support intraoperative awareness in scenarios where tactile feedback is reduced or visual confirmation is indirect. While CIT may enhance surgeon confidence during screw advancement, its clinical relevance, reproducibility, and impact on placement accuracy have yet to be validated. Full article
(This article belongs to the Special Issue Advances in Spine Surgery: Best Practices and Future Directions)
Show Figures

Figure 1

22 pages, 589 KiB  
Systematic Review
Current Trends and Future Directions in Lumbar Spine Surgery: A Review of Emerging Techniques and Evolving Management Paradigms
by Gianluca Galieri, Vittorio Orlando, Roberto Altieri, Manlio Barbarisi, Alessandro Olivi, Giovanni Sabatino and Giuseppe La Rocca
J. Clin. Med. 2025, 14(10), 3390; https://doi.org/10.3390/jcm14103390 - 13 May 2025
Cited by 1 | Viewed by 1580
Abstract
Background/Objectives: Lumbar spine surgery has undergone significant technological transformation in recent years, driven by the goals of minimizing invasiveness, improving precision, and enhancing clinical outcomes. Emerging tools—including robotics, augmented reality, computer-assisted navigation, and artificial intelligence—have complemented the evolution of minimally invasive surgical [...] Read more.
Background/Objectives: Lumbar spine surgery has undergone significant technological transformation in recent years, driven by the goals of minimizing invasiveness, improving precision, and enhancing clinical outcomes. Emerging tools—including robotics, augmented reality, computer-assisted navigation, and artificial intelligence—have complemented the evolution of minimally invasive surgical (MIS) approaches, such as endoscopic and lateral interbody fusions. Methods: This systematic review evaluates the literature from February 2020 to February 2025 on technological and procedural innovations in LSS. Eligible studies focused on degenerative lumbar pathologies, advanced surgical technologies, and reported clinical or perioperative outcomes. Randomized controlled trials, comparative studies, meta-analyses, and large case series were included. Results: A total of 32 studies met the inclusion criteria. Robotic-assisted surgery demonstrated high accuracy in pedicle screw placement (~92–94%) and reduced intraoperative blood loss and radiation exposure, although long-term clinical outcomes were comparable to conventional techniques. Intraoperative navigation improved instrumentation precision, while AR enhanced ergonomic workflow and reduced surgeon distraction. AI tools showed promise in surgical planning, guidance, and outcome prediction but lacked definitive evidence of clinical superiority. MIS techniques—including endoscopic discectomy and MIS-TLIF—offered reduced blood loss, shorter hospital stays, and faster recovery, with equivalent pain relief, fusion rates, and complication profiles compared to open procedures. Lateral and oblique approaches (XLIF/OLIF) further optimized alignment and indirect decompression, with favorable perioperative metrics. Conclusions: Recent innovations in lumbar spine surgery have enhanced technical precision and perioperative efficiency without compromising patient outcomes. While short-term benefits are clear, long-term clinical advantages and cost-effectiveness require further investigation. Integration of robotics, navigation, AI, and MIS into spine surgery reflects an ongoing shift toward personalized, data-driven, and less invasive care. Full article
(This article belongs to the Special Issue New Perspectives in Lumbar Spine Surgery: Treatment and Management)
Show Figures

Figure 1

15 pages, 2703 KiB  
Systematic Review
Accuracy and Safety Between Robot-Assisted and Conventional Freehand Fluoroscope-Assisted Placement of Pedicle Screws in Thoracolumbar Spine: Meta-Analysis
by Alberto Morello, Stefano Colonna, Enrico Lo Bue, Giulia Chiari, Giada Mai, Alessandro Pesaresi, Diego Garbossa and Fabio Cofano
Medicina 2025, 61(4), 690; https://doi.org/10.3390/medicina61040690 - 9 Apr 2025
Viewed by 1106
Abstract
Background and Objectives: Robotic-assisted surgery (RS) has progressively emerged as a promising technology in modern thoracolumbar spinal surgery, offering the potential to enhance accuracy and improve clinical outcomes. To date, the benefits of robot-assisted techniques in thoracolumbar spinal surgery remain controversial. The [...] Read more.
Background and Objectives: Robotic-assisted surgery (RS) has progressively emerged as a promising technology in modern thoracolumbar spinal surgery, offering the potential to enhance accuracy and improve clinical outcomes. To date, the benefits of robot-assisted techniques in thoracolumbar spinal surgery remain controversial. The objective of this study was to assess the efficacy and safety of RS compared to fluoroscopy-assisted surgery (FS) in spinal fusion procedures. Materials and Methods: In accordance with the PRISMA guidelines, a systematic review and meta-analysis was conducted, using REVMAN V5.3 software. The review protocol was registered in the Prospective Register of Systematic Reviews (PROSPERO) website with the following registration number: CRD42024567193. Results: Eighteen studies were included in the meta-analysis with a total of 1566 patients examined. The results demonstrated a worse accuracy in FS in cases with major violations of the peduncular cortex (D–E grades, according to Gertzbein’s classification) [(odds ratio (OR) 0.47, 95%-CI 0.28 to 0.80, I2 0%]. In addition, a lower complication rate was shown in the RS group compared to the FS group, specifically regarding the need for surgical revision due to screw mispositioning (OR 0.28-CI 0.17 to 0.48, I2 98%). Conclusions: Advantages of robot-assisted techniques were demonstrated in terms of postoperative complications, revision surgery rates, and the accuracy of screw placement. While RS represents a valuable and promising technological advancement in thoracolumbar spinal surgery, future studies are needed to further explore its advantages in thoracolumbar spinal surgery and to identify which spinal surgical approach has greater advantages when using the robot. Full article
(This article belongs to the Special Issue Spinal Neurosurgery: Current Treatment and Future Options)
Show Figures

Graphical abstract

10 pages, 3278 KiB  
Article
Augmented Reality in Scoliosis Correction Surgery: Efficiency and Accuracy in Pedicle Screw Instrumentation
by Chia-Ning Chang, Chi-Ruei Li, Sian-Siang Liao, Chiung-Chyi Shen, Kai-Yuan Chen, Chung-Hsin Lee and Meng-Yin Yang
Medicina 2025, 61(4), 576; https://doi.org/10.3390/medicina61040576 - 24 Mar 2025
Cited by 1 | Viewed by 677
Abstract
Background and Objectives: Recent advancements in spinal navigation methodologies, particularly augmented reality (AR) techniques, have significantly enhanced the precision of spinal instrumentation procedures. This study aimed to evaluate the efficacy of AR-assisted navigation in spinal instrumentation surgery for thoracolumbar scoliosis. Materials and [...] Read more.
Background and Objectives: Recent advancements in spinal navigation methodologies, particularly augmented reality (AR) techniques, have significantly enhanced the precision of spinal instrumentation procedures. This study aimed to evaluate the efficacy of AR-assisted navigation in spinal instrumentation surgery for thoracolumbar scoliosis. Materials and Methods: This retrospective observational study included 10 patients with thoracolumbar scoliosis who met specific inclusion criteria and were recruited at a single medical center. Two neurosurgeons and one neuroradiologist used the Gertzbein–Robbins scale (GRS) for radiological evaluation. Preoperative and postoperative Cobb angles were measured to assess the correction of scoliosis. Overall, 257 screws were placed using the AR-assisted navigation system during thoracic and lumbar spinal deformity surgeries. Results: Among the 257 screws, 197 were placed in the thoracic spine and 60 in the lumbar spine, achieving an overall instrumentation accuracy of 98%. The preoperative Cobb angle of 69.5 ± 22.2° significantly improved to 10.1 ± 4.1° postoperatively. Regarding first-attempt screw placement accuracy, 97.4% of the screws in the thoracic spine (graded as GRS A or B) and 100% in the lumbar spine were placed with precision. Five grade C thoracic screws were identified, one of which required re-instrumentation. Conclusions: The AR navigation technique substantially improved the precision of spinal deformity surgery, with a high screw placement accuracy rate and significant scoliosis correction. The benefits of reduced attention diversion and an intuitive surgical experience suggest that AR technology could significantly improve spinal surgery practices and training programs, indicating potential for broader applicability in the future. Full article
(This article belongs to the Special Issue New Frontiers in Spine Surgery and Spine Disorders)
Show Figures

Figure 1

11 pages, 2197 KiB  
Article
3D Digital Anatomical Models Based on Computed Tomographic Morphometric Analysis of C1 and C2 for Surgical Navigation
by Wongthawat Liawrungrueang, Watcharaporn Cholamjiak and Peem Sarasombath
J. Clin. Med. 2025, 14(1), 243; https://doi.org/10.3390/jcm14010243 - 3 Jan 2025
Viewed by 982
Abstract
Background/Objectives: Injuries involving the Atlas (C1) and Axis (C2) vertebrae of the cervical spine present significant clinical challenges due to their complex anatomy and potential for severe neurological impairment. Traditional imaging methods often lack the detailed visualization required for precise surgical planning. This [...] Read more.
Background/Objectives: Injuries involving the Atlas (C1) and Axis (C2) vertebrae of the cervical spine present significant clinical challenges due to their complex anatomy and potential for severe neurological impairment. Traditional imaging methods often lack the detailed visualization required for precise surgical planning. This study aimed to develop high-resolution 3D models of the C1 and C2 vertebrae to perform a comprehensive morphometric analysis, identify gender differences, and assess bilateral symmetry to enhance surgical accuracy. Methods: A retrospective analysis was conducted using CT scans from 500 patients aged 18 and older from a single-center hospital. Three-dimensional models were generated using InVesalius 3.1 and visualized with Meshmixer. Morphometric measurements included screw placement angles, lamina length and height, bicortical diameters, and pedicle widths. Statistical analyses were conducted using SPSS, with the Student’s t-test applied for gender and bilateral comparisons. Results: Significant gender differences were found in certain measurements, such as pedicle width (4.85 ± 0.90 mm in males vs. 4.60 ± 0.85 mm in females, p = 0.048) and C2 lamina height (12.90 ± 1.40 mm in males vs. 12.40 ± 1.25 mm in females, p = 0.033). Most measurements exhibited bilateral symmetry, supporting their applicability across genders. These results align with previous studies and highlight the importance of tailored surgical approaches. Conclusions: Three-dimensional models of the C1 and C2 provide comprehensive morphometric data that enhance preoperative planning and surgical precision. Integrating these models into clinical practice can reduce intraoperative risks and improve patient outcomes in cervical spine surgeries. Full article
(This article belongs to the Special Issue Challenges in Spinal Deformity)
Show Figures

Figure 1

19 pages, 17076 KiB  
Article
Enhancing the Accuracy of Pedicle Screw Placement Using 3D-Printed Screw-Guiding Techniques in the Lumbosacral Region for Small Breed Dogs: A Cadaveric Study
by Jin-Yeong Kim, Ho-Hyun Kwak, Heung-Myong Woo and Junhyung Kim
Animals 2025, 15(1), 14; https://doi.org/10.3390/ani15010014 - 25 Dec 2024
Cited by 2 | Viewed by 1332
Abstract
A 3D-printed guide is an effective method for accurately placing pedicle screws in dog vertebrae. While a conventional drill guide allows precise pilot hole formation, it can lead to potential screw wobbling during insertion. In this study, we applied a technique that assists [...] Read more.
A 3D-printed guide is an effective method for accurately placing pedicle screws in dog vertebrae. While a conventional drill guide allows precise pilot hole formation, it can lead to potential screw wobbling during insertion. In this study, we applied a technique that assists with both drilling and screw insertion, and we compared the accuracy of screw placement using this approach with that achieved by the conventional drill guide. The screws were divided into three groups: Group A (drill guide), Group B (cannulated guide), and Group C (screw guide). The accuracy of screw placement was assessed by comparing preoperative and postoperative CT images. Group A exhibited the largest angular deviation. Group C exhibited significantly smaller deviations in entry point, exit point, angle α, and angular deviation than Group A. In Group B, only the exit-point deviation was significantly smaller than that in Group A. Furthermore, the angular deviation in Group C was significantly smaller than that in Group B. In conclusion, 3D-printed screw-guiding techniques improved the accuracy of pedicle screw placement, with screw guides outperforming cannulated guides, making them a viable option for small breed dogs. Full article
(This article belongs to the Section Veterinary Clinical Studies)
Show Figures

Figure 1

11 pages, 2953 KiB  
Article
Evaluation of Pedicle Screw Position on Computerized Tomography Using Three-Dimensional Reconstruction Software
by Jiwon Park, Jin S. Yeom, Yeonho Kim, Yoonjoong Hwang, Namkug Kim and Sang-Min Park
Medicina 2024, 60(12), 2040; https://doi.org/10.3390/medicina60122040 - 11 Dec 2024
Viewed by 1239
Abstract
Background and Objectives: Recent advances in intraoperative navigation systems have improved the accuracy of pedicle screw placement in spine surgery. However, many hospitals have limited access to these advanced technologies due to resource constraints. In such settings, postoperative computed tomography (CT) evaluation [...] Read more.
Background and Objectives: Recent advances in intraoperative navigation systems have improved the accuracy of pedicle screw placement in spine surgery. However, many hospitals have limited access to these advanced technologies due to resource constraints. In such settings, postoperative computed tomography (CT) evaluation remains crucial for assessing screw placement and related potential complications. Metal artifacts in CT scans often compromise the diagnostic accuracy. This study aimed to develop and validate three-dimensional (3-D) reconstruction software to enhance screw localization accuracy and facilitate its practical clinical application. Materials and Methods: This study included two phases: 3-D software development utilizing specific threshold values of Hounsfield units for titanium screws followed by internal validation. For validation, fifty pedicle screws were inserted into porcine lumbar vertebrae with random violation (superior, inferior, medial, or lateral). Three fellowship-trained surgeons evaluated screw positions using both conventional CT bone window settings and the developed software. Additional clinical validation involving 386 pedicle screws from cervical to lumbar spine was performed by two surgeons. Results: The software demonstrated significantly higher specificity (83% vs. 63%) and positive predictive value (96% vs. 91%) compared to conventional CT bone window settings, while maintaining 100% sensitivity and negative predictive value. Interobserver reliability was excellent for both methods (0.961 for bone window vs. 0.990 for software). In clinical validation, the software showed superior intraobserver (0.83 vs. 0.74) and interobserver reliability (0.855 vs. 0.513) compared to picture archiving and communication system (PACS) workstation evaluation. Conclusions: The developed software provides improved accuracy and reliability in pedicle screw position evaluation through distinct screw outline visualization and metal artifact reduction. Its equipment-independent nature and cost-effectiveness make it particularly valuable for clinical implementation. Full article
(This article belongs to the Section Orthopedics)
Show Figures

Figure 1

16 pages, 3473 KiB  
Article
Development and Validation of Deep Learning Preoperative Planning Software for Automatic Lumbosacral Screw Selection Using Computed Tomography
by Baodong Wang, Congying Zou, Xingyu Liu, Dong Liu, Yiling Zhang and Lei Zang
Bioengineering 2024, 11(11), 1094; https://doi.org/10.3390/bioengineering11111094 - 30 Oct 2024
Cited by 2 | Viewed by 1472
Abstract
Achieving precise pedicle screw placement in posterior lumbar interbody fusion (PLIF) is essential but difficult due to the intricacies of manual preoperative planning with CT scans. We analyzed CT data from 316 PLIF patients, using Mimics software for manual planning by two surgeons. [...] Read more.
Achieving precise pedicle screw placement in posterior lumbar interbody fusion (PLIF) is essential but difficult due to the intricacies of manual preoperative planning with CT scans. We analyzed CT data from 316 PLIF patients, using Mimics software for manual planning by two surgeons. A deep learning model was trained on 228 patients and validated on 88 patients, assessing planning efficiency and accuracy. Automatic planning successfully segmented and placed screws in all 316 cases, significantly outperforming manual planning in speed. The Dice coefficient for segmentation accuracy was 0.95. The difference in mean pedicle transverse angle (PTA) and pedicle sagittal angle (PSA) for automatic planning screws compared to manual planning screws was 1.63 ± 0.83° and 1.39 ± 1.03°, respectively, and these differences were either statistically comparable or not significantly different compared to the variability of manual planning screws. The average Dice coefficient of implanted screws was 0.63 ± 0.08, and the consistency between automatic screws and manual reference screws was higher than that of internal screws (Dice 0.62 ± 0.09). Compared with manual screws, automatic screws were shorter (46.58 ± 3.09 mm) and thinner (6.24 ± 0.35 mm), and the difference was statistically significant. In qualitative validation, 97.7% of the automatic planning screws were rated Gertzbein–Robbins (GR) Class A and 97.3% of the automatic planning screws were rated Badu Class 0. Deep learning software automates lumbosacral pedicle screw planning, enhancing surgical efficiency and accuracy. Full article
(This article belongs to the Special Issue AI and Big Data Research in Biomedical Engineering)
Show Figures

Graphical abstract

12 pages, 3010 KiB  
Article
Overcoming the Learning Curve in Robot-Assisted Spinal Surgery—How Does It Compare to O-Arm Navigation?
by Pirateb Paramasivam Meenakshi Sundaram, Mun Chun Lai, Arun-Kumar Kaliya-Perumal and Jacob Yoong-Leong Oh
Surgeries 2024, 5(4), 896-907; https://doi.org/10.3390/surgeries5040072 - 30 Sep 2024
Cited by 2 | Viewed by 1976
Abstract
Background: Robotic systems have the potential to significantly enhance the accuracy and outcomes of spinal surgery. Adopting this new technology requires an examination of its learning curve and influencing factors. This study analyzes the learning curve associated with using the Mazor X Stealth [...] Read more.
Background: Robotic systems have the potential to significantly enhance the accuracy and outcomes of spinal surgery. Adopting this new technology requires an examination of its learning curve and influencing factors. This study analyzes the learning curve associated with using the Mazor X Stealth Edition system for pedicle screw placement and performs a matched-pair analysis to compare operative durations between robot-assisted and navigation-based surgeries, evaluating the efficiency of the robotic system. Methods: We collected retrospective operative data from patients who underwent robot-assisted pedicle screw placements between December 2020 and June 2024 and conducted a cumulative sum (CuSUM) analysis to assess the learning curve, focusing on the robotic system’s setup duration. Additionally, we compared a group of patients who underwent robot-assisted pedicle screw placements with a pair-matched group who underwent O-arm-based navigation-assisted pedicle screw placements. Results: There was a notable decrease in the robotic setup duration, with a significant shift in trend observed after the first 20 cases. While the initial setup time was 24 minutes, it reduced to 17 minutes in later cases, reflecting a marked improvement in efficiency as the surgeon gained more experience with the robot. Conclusion: Our findings indicate there were no added difficulties using the robotic system compared to the navigation system. Moreover, the learning curve for the robotic system can be quickly surmounted, and it offers clear advantages over previous systems, making it a valuable tool for pedicle screw application. Full article
Show Figures

Graphical abstract

11 pages, 277 KiB  
Review
Augmenting Reality in Spinal Surgery: A Narrative Review of Augmented Reality Applications in Pedicle Screw Instrumentation
by Sheng-Xian Xiao, Wen-Tien Wu, Tzai-Chiu Yu, Ing-Ho Chen and Kuang-Ting Yeh
Medicina 2024, 60(9), 1485; https://doi.org/10.3390/medicina60091485 - 12 Sep 2024
Cited by 9 | Viewed by 1997
Abstract
Background and Objectives: The advent of augmented reality (AR) in spinal surgery represents a key technological evolution, enhancing precision and safety in procedures such as pedicle screw instrumentation. This review assesses the current applications, benefits, and challenges of AR technology in spinal [...] Read more.
Background and Objectives: The advent of augmented reality (AR) in spinal surgery represents a key technological evolution, enhancing precision and safety in procedures such as pedicle screw instrumentation. This review assesses the current applications, benefits, and challenges of AR technology in spinal surgery, focusing on its effects on surgical accuracy and patient outcomes. Materials and Methods: A comprehensive review of the literature published between January 2023 and December 2024 was conducted, focusing on AR and navigational technologies in spinal surgery. Key outcomes such as accuracy, efficiency, and complications were emphasized. Results: Thirteen studies were included, highlighting substantial improvements in surgical accuracy, efficiency, and safety with AR and navigational systems. AR technology was found to significantly reduce the learning curve for spinal surgeons, improve procedural efficiency, and potentially reduce surgical complications. The challenges identified include high system costs, the complexity of training requirements, the integration with existing workflows, and limited clinical evidence. Conclusions: AR technology holds promise for advancements in spinal surgery, particularly in improving the accuracy and safety of pedicle screw instrumentation. Despite existing challenges such as cost, training needs, and regulatory hurdles, AR has the potential to transform spinal surgical practices. Ongoing research, technological refinements, and the development of implementation strategies are essential to fully leverage AR’s capabilities in enhancing patient care. Full article
(This article belongs to the Section Surgery)
11 pages, 6575 KiB  
Article
High Accuracy of Three-Dimensional Navigated Kirschner-Wire-Less Single-Step Pedicle Screw System (SSPSS) in Lumbar Fusions: Comparison of Intraoperatively Planned versus Final Screw Position
by Mateusz Bielecki, Blake I. Boadi, Yizhou Xie, Chibuikem A. Ikwuegbuenyi, Minaam Farooq, Jessica Berger, Alan Hernández-Hernández, Ibrahim Hussain and Roger Härtl
Brain Sci. 2024, 14(9), 873; https://doi.org/10.3390/brainsci14090873 - 29 Aug 2024
Viewed by 1715
Abstract
(1) Background: Our team has previously introduced the Single-Step Pedicle Screw System (SSPSS), which eliminates the need for K-wires, as a safe and effective method for percutaneous minimally invasive spine (MIS) pedicle screw placement. Despite this, there are ongoing concerns about the reliability [...] Read more.
(1) Background: Our team has previously introduced the Single-Step Pedicle Screw System (SSPSS), which eliminates the need for K-wires, as a safe and effective method for percutaneous minimally invasive spine (MIS) pedicle screw placement. Despite this, there are ongoing concerns about the reliability and accuracy of screw placement in MIS procedures without traditional tools like K-wires and Jamshidi needles. To address these concerns, we evaluated the accuracy of the SSPSS workflow by comparing the planned intraoperative screw trajectories with the final screw positions. Traditionally, screw placement accuracy has been assessed by grading the final screw position using postoperative CT scans. (2) Methods: We conducted a retrospective review of patients who underwent lumbar interbody fusion, using intraoperative 3D navigation for screw placement. The planned screw trajectories were saved in the navigation system during each procedure, and postoperative CT scans were used to evaluate the implanted screws. Accuracy was assessed by comparing the Gertzbein and Robbins classification scores of the planned trajectories and the final screw positions. Accuracy was defined as a final screw position matching the classification of the planned trajectory. (3) Results: Out of 206 screws, 196 (95%) were accurately placed, with no recorded complications. (4) Conclusions: The SSPSS workflow, even without K-wires and other traditional instruments, facilitates accurate and reliable pedicle screw placement. Full article
(This article belongs to the Special Issue Advanced Clinical Technologies in Treating Neurosurgical Diseases)
Show Figures

Figure 1

Back to TopTop