Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (17)

Search Parameters:
Keywords = laminated glazing

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
28 pages, 7005 KB  
Article
The Development and Performance of a Novel Switchable Shading Device
by Etienne Magri, Vincent Buhagiar and Mauro Overend
Buildings 2026, 16(8), 1519; https://doi.org/10.3390/buildings16081519 - 13 Apr 2026
Viewed by 460
Abstract
Existing buildings with large glazing ratios within subtropical Mediterranean climates face substantial challenges for thermal and visual control of their indoor environment. Previous research by the same authors has already identified the potential of incorporating both solar–PDLC (polymer-dispersed liquid crystal) and SPD (suspended [...] Read more.
Existing buildings with large glazing ratios within subtropical Mediterranean climates face substantial challenges for thermal and visual control of their indoor environment. Previous research by the same authors has already identified the potential of incorporating both solar–PDLC (polymer-dispersed liquid crystal) and SPD (suspended particle device) switchable films within facades exposed to high solar insolation to provide a wide dynamic range of visual transparencies. This paper identifies a novel application for switchable laminates within a dynamic external shading device that permits the casting of a shadow on demand onto existing fenestration. This study compares the degree of glare within an enclosed space attained by a conventional opaque overhang over a window to that achieved with glass shading overhangs incorporating two types of switchable films. Using a scale model in a field test setting, indoor illumination and glare measurements are investigated under different states of switchable films and compared to those provided by conventional static glazing, with and without ordinary external overhangs under identical field test conditions. Results show that switchable overhangs in their transparent/bleached state can allow the ingress of daylight without creating excessive glare, whereas in their translucent/tinted state, switchable shades can deliver a level of glare protection similar to that provided by an opaque shading overhang. Full article
(This article belongs to the Special Issue Daylighting and Environmental Interactions in Building Design)
Show Figures

Figure 1

25 pages, 5641 KB  
Article
Comparative Thermal Performance and Return on Investment of Glazing Configurations in Building Envelopes: The Case of the Plataforma Gubernamental Norte in Quito, Ecuador
by Patricio Simbaña-Escobar, Santiago Mena-Hernández, Evelyn Chérrez Córdova and Natalia Alvarado-Arias
Buildings 2025, 15(19), 3522; https://doi.org/10.3390/buildings15193522 - 30 Sep 2025
Cited by 2 | Viewed by 1498
Abstract
Glazed façades play a decisive role in building energy performance, particularly in high-radiation equatorial climates. This study examines the thermal behavior and economic feasibility of three glazing systems—10 mm monolithic clear glass, laminated solar-control glass, and selective double glazing—applied to the Plataforma Gubernamental [...] Read more.
Glazed façades play a decisive role in building energy performance, particularly in high-radiation equatorial climates. This study examines the thermal behavior and economic feasibility of three glazing systems—10 mm monolithic clear glass, laminated solar-control glass, and selective double glazing—applied to the Plataforma Gubernamental Norte, the largest institutional building in Ecuador. Dynamic simulations using DesignBuilder with the EnergyPlus engine assessed solar gains, HVAC demand, and operative temperatures, complemented by a sensitivity analysis of SHGC, U-value, and Tvis. Results indicate that selective double glazing reduced annual HVAC consumption by 78.21% (110.6 MWh), while laminated glazing achieved a 55.40% reduction. SHGC and U-value emerged as the most influential parameters, whereas Tvis had no impact on energy loads. Despite strong technical performance, the economic analysis revealed payback periods exceeding 235 years under Ecuador’s subsidized tariff (USD 0.10/kWh), compared to the 18–25 years commonly observed in Europe. This highlights the “efficiency paradox”: advanced glazing solutions deliver significant energy savings but remain financially unfeasible in subsidy-driven contexts. The findings underscore the need for policy reforms to better align façade design strategies with energy resilience, an issue particularly relevant after Ecuador’s 2024 electricity crisis and ongoing debates on subsidy elimination. Full article
Show Figures

Figure 1

23 pages, 2810 KB  
Article
Engineering Analysis and Design Method for Blast-Resistant Laminated Glass Composite Systems
by Ahmed Elkilani, Hani Salim and Ahmed Elbelbisi
J. Compos. Sci. 2025, 9(9), 466; https://doi.org/10.3390/jcs9090466 - 1 Sep 2025
Cited by 1 | Viewed by 2015
Abstract
Laminated glass (LG) composite systems are increasingly being utilized in architectural and security applications due to their enhanced strength and safety features. Understanding the structural response of LG systems is crucial for optimizing their performance under blast loads. This paper presents a comprehensive [...] Read more.
Laminated glass (LG) composite systems are increasingly being utilized in architectural and security applications due to their enhanced strength and safety features. Understanding the structural response of LG systems is crucial for optimizing their performance under blast loads. This paper presents a comprehensive study of an analytical model for predicting the static and dynamic resistance functions of various LG systems used in blast-resistant designs to advance engineering analysis and design methods. The proposed analytical model integrates the strain-rate-dependent interlayer behavior with the glass dynamic increase factors to generate a physically consistent post-fracture membrane resistance, offering a unified framework for deriving the static and dynamic resistance functions directly applicable to single-degree-of-freedom (SDOF) analyses across different LG layups. The developed models were validated statistically using full-scale water chamber results and dynamically against experimental blast field data and the results from shock tube testing. We validated the model’s accuracy for various LG layup configurations, including variations in the glass and interlayer sizes, types, and thicknesses. The established dynamic resistance model was developed by incorporating a strain-rate-dependent interlayer material model. The energy absorption of LG panels, influenced by factors like interlayer thickness and type, is critical for blast design, as it determines the panels’ ability to withstand and dissipate energy, thereby reducing the transmitted forces and deformations to a building’s structure. The dynamic model closely matched the dynamic deflection time histories, with a maximum difference of 6% for all the blast experiments. The static resistance validations across the various LG configurations consistently demonstrated reliable prediction results. The energy absorption comparisons between the analytical and quasi-static LG panel responses ranged from 1% to 17%. These advancements provide higher-fidelity SDOF predictions and clear guidance for selecting the interlayer type and thickness to optimize energy absorption. This will result in enhanced blast resistance and contribute to more effective blast mitigation in glazing system design. Full article
Show Figures

Figure 1

28 pages, 5782 KB  
Article
Design of a Shipping Container-Based Home: Structural, Thermal, and Acoustic Conditioning
by Javier Pinilla-Melo, Jose Ramón Aira-Zunzunegui, Giuseppe La Ferla, Daniel de la Prida and María Ángeles Navacerrada
Buildings 2025, 15(17), 3127; https://doi.org/10.3390/buildings15173127 - 1 Sep 2025
Cited by 3 | Viewed by 7929
Abstract
The construction of buildings using shipping containers (SCs) is a way to extend their useful life. They are constructed by modifying the structure, thermal, and acoustic conditioning by improving the envelope and creating openings for lighting and ventilation purposes. This study explores the [...] Read more.
The construction of buildings using shipping containers (SCs) is a way to extend their useful life. They are constructed by modifying the structure, thermal, and acoustic conditioning by improving the envelope and creating openings for lighting and ventilation purposes. This study explores the architectural adaptation of SCs to sustainable residential housing, focusing on structural, thermal, and acoustic performance. The project centers on a case study in Madrid, Spain, transforming four containers into a semi-detached, multilevel dwelling. The design emphasizes modular coordination, spatial flexibility, and structural reinforcement. The retrofit process includes the integration of thermal insulation systems in the ventilated façades and sandwich roof panels to counteract steel’s high thermal conductivity, enhancing energy efficiency. The acoustic performance of the container-based dwelling was assessed through in situ measurements of façade airborne sound insulation and floor impact noisedemonstrating compliance with building code requirements by means of laminated glazing, sealed joints, and floating floors. This represents a novel contribution, given the scarcity of experimental acoustic data for residential buildings made from shipping containers. Results confirm that despite the structure’s low surface mass, appropriate design strategies can achieve the required sound insulation levels, supporting the viability of this lightweight modular construction system. Structural calculations verify the building’s load-bearing capacity post-modification. Overall, the findings support container architecture as a viable and eco-efficient alternative to conventional construction, while highlighting critical design considerations such as thermal performance, sound attenuation, and load redistribution. The results offer valuable data for designers working with container-based systems and contribute to a strategic methodology for the sustainable refurbishment of modular housing. Full article
Show Figures

Figure 1

39 pages, 9517 KB  
Article
Multidimensional Evaluation Framework and Classification Strategy for Low-Carbon Technologies in Office Buildings
by Hongjiang Liu, Yuan Song, Yawei Du, Tao Feng and Zhihou Yang
Buildings 2025, 15(15), 2689; https://doi.org/10.3390/buildings15152689 - 30 Jul 2025
Cited by 1 | Viewed by 1528
Abstract
The global climate crisis has driven unprecedented agreements among nations on carbon mitigation. With China’s commitment to carbon peaking and carbon neutrality targets, the building sector has emerged as a critical focus for emission reduction, particularly because office buildings account for over 30% [...] Read more.
The global climate crisis has driven unprecedented agreements among nations on carbon mitigation. With China’s commitment to carbon peaking and carbon neutrality targets, the building sector has emerged as a critical focus for emission reduction, particularly because office buildings account for over 30% of building energy consumption. However, a systematic and regionally adaptive low-carbon technology evaluation framework is lacking. To address this gap, this study develops a multidimensional decision-making system to quantify and rank low-carbon technologies for office buildings in Beijing. The method includes four core components: (1) establishing three archetypal models—low-rise (H ≤ 24 m), mid-rise (24 m < H ≤ 50 m), and high-rise (50 m < H ≤ 100 m) office buildings—based on 99 office buildings in Beijing; (2) classifying 19 key technologies into three clusters—Envelope Structure Optimization, Equipment Efficiency Enhancement, and Renewable Energy Utilization—using bibliometric analysis and policy norm screening; (3) developing a four-dimensional evaluation framework encompassing Carbon Reduction Degree (CRD), Economic Viability Degree (EVD), Technical Applicability Degree (TAD), and Carbon Intensity Degree (CID); and (4) conducting a comprehensive quantitative evaluation using the AHP-entropy-TOPSIS algorithm. The results indicate distinct priority patterns across the building types: low-rise buildings prioritize roof-mounted photovoltaic (PV) systems, LED lighting, and thermal-break aluminum frames with low-E double-glazed laminated glass. Mid- and high-rise buildings emphasize integrated PV-LED-T8 lighting solutions and optimized building envelope structures. Ranking analysis further highlights LED lighting, T8 high-efficiency fluorescent lamps, and rooftop PV systems as the top-recommended technologies for Beijing. Additionally, four policy recommendations are proposed to facilitate the large-scale implementation of the program. This study presents a holistic technical integration strategy that simultaneously enhances the technological performance, economic viability, and carbon reduction outcomes of architectural design and renovation. It also establishes a replicable decision-support framework for decarbonizing office and public buildings in cities, thereby supporting China’s “dual carbon” goals and contributing to global carbon mitigation efforts in the building sector. Full article
Show Figures

Figure 1

20 pages, 5297 KB  
Article
The Validation and Discussion of a Comparative Method Based on Experiment to Determine the Effective Thickness of Composite Glass
by Dake Cao, Xiaogen Liu, Zhe Yang, Jiawei Huang, Ming Xu and Detian Wan
Buildings 2025, 15(14), 2542; https://doi.org/10.3390/buildings15142542 - 19 Jul 2025
Viewed by 1143
Abstract
This study introduces and validates a comparative experiment-based method for determining the effective thickness of composite glass, including polymeric laminated glass (with polyvinyl butyral (PVB) and SentryGlas® (SGP) interlayers) and vacuum glazing. This method employs comparative four-point bending tests, defining effective thickness [...] Read more.
This study introduces and validates a comparative experiment-based method for determining the effective thickness of composite glass, including polymeric laminated glass (with polyvinyl butyral (PVB) and SentryGlas® (SGP) interlayers) and vacuum glazing. This method employs comparative four-point bending tests, defining effective thickness by equating the bending stress of a composite specimen to that of a reference monolithic glass specimen under identical loading and boundary conditions. Specimens with varying configurations (glass thicknesses of 5 mm, 6 mm and 8 mm) were tested using non-destructive four-point bending tests under a multi-stage loading protocol (100 N–1000 N). Strain rosettes measured maximum strains at each loading stage to calculate bending stress. Analysis of the bending stress state revealed that vacuum glazing and SGP laminated glass exhibit superior load-bearing capacity compared to PVB laminated glass. The proposed method successfully determined the effective thickness for both laminated glass and vacuum glazing. Furthermore, results demonstrate that employing a 12 mm monolithic reference glass provides the highest accuracy for effective thickness determination. Theoretical bending stress calculations using the effective thickness derived from the 12 mm reference glass showed less than 10% deviation from experimental values. Conversely, compared to established standards and empirical formulas, the proposed method offers superior accuracy, particularly for vacuum glazing. Additionally, the mechanical properties of the viscoelastic interlayers (PVB and SGP) were investigated through static tensile tests and dynamic thermomechanical analysis (DMA). Distinct tensile behaviors and differing time-dependent shear transfer capacities between the two interlayer materials are found out. Key factors influencing the reliability of the method are also discussed and analyzed. This study provides a universally practical and applicable solution for accurate and effective thickness estimation in composite glass design. Full article
(This article belongs to the Section Building Materials, and Repair & Renovation)
Show Figures

Figure 1

14 pages, 4005 KB  
Article
Characterization of the TCO Layer on a Glass Surface for PV IInd and IIIrd Generation Applications
by Paweł Kwaśnicki, Anna Gronba-Chyła, Agnieszka Generowicz, Józef Ciuła, Agnieszka Makara and Zygmunt Kowalski
Energies 2024, 17(13), 3122; https://doi.org/10.3390/en17133122 - 25 Jun 2024
Cited by 11 | Viewed by 3538
Abstract
In the dynamic field of photovoltaic technology, the pursuit of efficiency and sustainability has led to continuous novelty, shaping the landscape of solar energy solutions. One of the key elements affecting the efficiency of photovoltaic cells of IInd and IIIrd generation [...] Read more.
In the dynamic field of photovoltaic technology, the pursuit of efficiency and sustainability has led to continuous novelty, shaping the landscape of solar energy solutions. One of the key elements affecting the efficiency of photovoltaic cells of IInd and IIIrd generation is the presence of transparent conductive oxide (TCO) layers, which are key elements impacting the efficiency and durability of solar panels, especially for DSSC, CdTe, CIGS (copper indium gallium diselenide) or organic, perovskite and quantum dots. TCO with low electrical resistance, high mobility, and high transmittance in the VIS–NIR region is particularly important in DSSC, CIGS, and CdTe solar cells, working as a window and electron transporting layer. This layer must form an ohmic contact with the adjacent layers, typically the buffer layer (such as CdS or ZnS), to ensure efficient charge collection Furthermore it ensures protection against oxidation and moisture, which is especially important when transporting the active cell structure to further process steps such as lamination, which ensures the final seal. Transparent conductive oxide layers, which typically consist of materials such as indium tin oxide (ITO) or alternatives such as fluorine-doped tin oxide (FTO), serve dual purposes in photovoltaic applications. Primarily located as the topmost layer of solar cells, TCOs play a key role in transmitting sunlight while facilitating the efficient collection and transport of generated electrical charges. This complex balance between transparency and conductivity highlights the strategic importance of TCO layers in maximizing the performance and durability of photovoltaic systems. As the global demand for clean energy increases and the photovoltaic industry rapidly develops, understanding the differential contribution of TCO layers becomes particularly important in the context of using PV modules as building-integrated elements (BIPV). The use of transparent or semi-transparent modules allows the use of building glazing, including windows and skylights. In addition, considering the dominant position of the Asian market in the production of cells and modules based on silicon, the European market is intensifying work aimed at finding a competitive PV technology. In this context, thin-film, organic modules may prove competitive. For this purpose, in this work, we focused on the electrical parameters of two different thicknesses of a transparent FTO layer. First, the influence of the FTO layer thickness on the transmittance over a wide range was verified. Next, the chemical composition was determined, and key electrical parameters, including carrier mobility, resistivity, and the Hall coefficient, were determined. Full article
(This article belongs to the Section A2: Solar Energy and Photovoltaic Systems)
Show Figures

Figure 1

26 pages, 10643 KB  
Article
The Influence of Strain Rate Behavior on Laminated Glass Interlayer Types for Cured and Uncured Polymers
by Ahmed Elkilani, Hesham EL-Emam, Alaa Elsisi, Ahmed Elbelbisi and Hani Salim
Polymers 2024, 16(6), 730; https://doi.org/10.3390/polym16060730 - 7 Mar 2024
Cited by 22 | Viewed by 5557
Abstract
Recent explosions and impact events have highlighted the exposure of civil structures, prompting the need for resilient new constructions and retrofitting of existing ones. Laminated glass panels, particularly in glazed facades, are increasingly used to enhance blast resistance. However, the understanding of glass [...] Read more.
Recent explosions and impact events have highlighted the exposure of civil structures, prompting the need for resilient new constructions and retrofitting of existing ones. Laminated glass panels, particularly in glazed facades, are increasingly used to enhance blast resistance. However, the understanding of glass fragments and their interaction with the interlayer is still incomplete. This paper investigates experimentally the quasi-static and dynamic responses of cured and uncured polymers for seven different materials—two different products of polyvinyl butyral (PVB), two ethylene vinyl acetate products (EVA), one product of thermoplastic polyurethane (TPU), and two SentryGlas products (SG)—that were tested between 21 and 32 °C (69.8 and 89.6 °F), which is the recommended room temperature. In these experiments, the responses of PVB, EVA, TPU, and SG were evaluated under a quasi-static strain rate of 0.033 s−1 and compared to the results under a relatively higher strain rate of 2 s−1. Moreover, the high strain rate loading of the materials was accomplished using a drop-weight testing appliance to evaluate the engineering stress–strain response under strain rates between 20 and 50 s−1. The results demonstrated that with strain rates of 20 s−1, PVB behaved like a material with viscoelastic characteristics, but at 45 s−1 strain rates, PVB became a non-elastic material. SG, on the other hand, offered both a high stiffness and a high level of transparency, making it a very good alternative to PVB in structural applications. In contrast, after the maximum stress point, the response to the failure of the seven materials differed significantly. The tests provided ample information for evaluating alternative approaches to modeling these different materials in blast events. Full article
(This article belongs to the Section Polymer Processing and Engineering)
Show Figures

Figure 1

23 pages, 5585 KB  
Article
Application of Composite Bars in Wooden, Full-Scale, Innovative Engineering Products—Experimental and Numerical Study
by Agnieszka Wdowiak-Postulak, Grzegorz Świt and Ilona Dziedzic-Jagocka
Materials 2024, 17(3), 730; https://doi.org/10.3390/ma17030730 - 3 Feb 2024
Cited by 22 | Viewed by 2903
Abstract
The commercialization of modular timber products as cost-effective and lightweight components has resulted in innovative engineering products, e.g., glued laminated timber, laminated veneer lumber, I-beams, cross-laminated timber and solid timber joined with wedge joints. With the passage of time, timber structures can deteriorate, [...] Read more.
The commercialization of modular timber products as cost-effective and lightweight components has resulted in innovative engineering products, e.g., glued laminated timber, laminated veneer lumber, I-beams, cross-laminated timber and solid timber joined with wedge joints. With the passage of time, timber structures can deteriorate, or new structural elements are required to increase the stiffness or load-bearing capacity in newly built structures, e.g., lintels over large-scale glazing or garages, or to reduce cross-sectional dimensions or save costly timber material while still achieving low weight. It is in such cases that repair or correct reinforcement is required. In this experimental and numerical study, the static performance of flexural timber beams reinforced with prestressed basalt BFRP, glass GFRP and hybrid glass–basalt fiber bars is shown. The experimental tests resulted in an increase in the load-carrying capacity of BFRP (44%), GFRP (33%) and hybrid bars (43%) and an increase in the stiffness of BFRP (28%), GFRP (24%) and hybrid bars (25%). In addition to this, glued laminated timber beams reinforced with prestressed basalt rods subjected to biological degradation, 7 years of weathering and prolonged exposure to various environmental conditions were examined, and an increase in the load-bearing capacity of 27% and an increase in stiffness of 28% were obtained. In addition, full-size laminated timber beams reinforced with prestressed basalt bars were investigated in the field as an exploratory test under fire conditions at elevated temperatures, and the effect of the physical–mechanical properties during the fire was examined via an analysis of these properties after the fire. In addition, a satisfactory correlation of the numerical simulations with the experimental studies was obtained. The differences were between 1.1% and 5.5%. The concordance was due to the fact that, in this study, the Young, Poisson and shear moduli were determined for all quality classes of sawn timber. Only a significant difference resulted in the numerical analysis for the beams exposed to fire under fire conditions. The experimental, theoretical and numerical analyses in this research were exploratory and will be expanded as directions for future research. Full article
(This article belongs to the Special Issue Testing of Materials and Elements in Civil Engineering (3rd Edition))
Show Figures

Figure 1

23 pages, 4787 KB  
Review
Ultraviolet Radiation Transmission in Buildings’ Fenestration: Part I, Detection Methods and Approaches Using Spectrophotometer and Radiometer
by Damilola Adeniyi Onatayo, Ravi Shankar Srinivasan and Bipin Shah
Buildings 2023, 13(7), 1670; https://doi.org/10.3390/buildings13071670 - 29 Jun 2023
Cited by 10 | Viewed by 9119
Abstract
Fenestration, comprising windows and other openings in a building, influences occupant health and well-being while also enhancing energy efficiency through optimized design and placement. Selecting glazing materials that block or filter harmful UV radiation is crucial, as is having reliable methods to measure [...] Read more.
Fenestration, comprising windows and other openings in a building, influences occupant health and well-being while also enhancing energy efficiency through optimized design and placement. Selecting glazing materials that block or filter harmful UV radiation is crucial, as is having reliable methods to measure their UV transmission. This research paper, which comprises Part I of II, conducts an exhaustive analysis of the predominant methodologies and associated challenges inherent in assessing ultraviolet (UV) radiation transmission and deterioration status in fenestration, with particular emphasis on the usage of spectrophotometers and radiometers. It details the economic and operational challenges associated with these instruments and the limitations they pose in terms of sample size and the impact of glazing material degradation over time. Additionally, the paper provides a comparative analysis of UV radiation transmission characteristics across different glazing configurations such as green or yellow patterned glass, laminate glass, clear glass treated with UV protection film, and float glass. The review identifies laminated glass material as offering the best protection. Although spectrophotometers and radiometers offer high levels of accuracy in transmission data detection, their adoption is hindered by considerable financial and operational challenges. The paper underscores the need for developing alternative methodologies that are economically viable, operationally less complex, and are capable of overcoming the limitations of the traditional methods of detection, which will facilitate optimal fenestration configurations for UV protection and energy efficiency in buildings. The proposed Part II paper will explore UV imaging, image processing, and computer vision techniques as potential alternative approaches. Full article
(This article belongs to the Section Building Energy, Physics, Environment, and Systems)
Show Figures

Figure 1

22 pages, 8819 KB  
Article
Effect of Interlayer Materials on Fire Performance of Laminated Glass Used in High-Rise Building: Cone Calorimeter Testing
by Md Kamrul Hassan, Md Rayhan Hasnat, Kai Png Loh, Md Delwar Hossain, Payam Rahnamayiezekavat, Grahame Douglas and Swapan Saha
Fire 2023, 6(3), 84; https://doi.org/10.3390/fire6030084 - 22 Feb 2023
Cited by 16 | Viewed by 6949
Abstract
Laminated glass is prominently used nowadays as building construction material in the façade and architectural glazing of high-rise buildings. On the other hand, the fire safety of the high-rise building with laminated glass is also receiving more attention from the fire safety regulatory [...] Read more.
Laminated glass is prominently used nowadays as building construction material in the façade and architectural glazing of high-rise buildings. On the other hand, the fire safety of the high-rise building with laminated glass is also receiving more attention from the fire safety regulatory authorities and researchers due to recent fire incidents. Different interlayer polymeric materials are used in modern laminated glass to prevent the breakage of the glass façade, which can also increase the fire risk through a lower ignition time, and higher heat release and smoke production. Therefore, further research is required to understand the fire behaviour of laminated glass. In this study, the fire performance of the laminated glass has been investigated using cone calorimeter testing and the effect of different parameters such as glass thickness (6, 10, 12 mm), interlayer materials (PVB, SGP and EVA) and heat flux (25, 50 and 75 kW/m2) on the fire behaviour of laminated glass has been studied. It is found that the glass thickness, interlayer material and heat flux can significantly influence the reaction-to-fire properties such as peak heat release rate (pHRR), total heat release, time to ignition, and smoke production of laminated glass. In addition, total smoke production (TSP) is also very high for PVB (3.146 m2) and SGP (3.898 m2) laminated glass compared to EVA (0.401 m2) laminated glass and it is affected by these parameters. Finally, a simplified equation is developed to predict the pHRR of laminated glass by correlating the mass loss and external heat flux. Full article
Show Figures

Figure 1

17 pages, 4673 KB  
Article
Sound Insulation of Façade Element with Triple IGU
by Raimondas Bliūdžius, Kęstutis Miškinis, Vincent Buhagiar and Karolis Banionis
Buildings 2022, 12(8), 1239; https://doi.org/10.3390/buildings12081239 - 14 Aug 2022
Cited by 8 | Viewed by 3683
Abstract
Sound insulation design for structural glazed façade is an important task in environmental noise control, as increased continuously repeated noise is a significant factor impacting on people’s well-being and is associated with a negative impact on their health. For façades, in addition to [...] Read more.
Sound insulation design for structural glazed façade is an important task in environmental noise control, as increased continuously repeated noise is a significant factor impacting on people’s well-being and is associated with a negative impact on their health. For façades, in addition to sound insulation, requirements for safe use and high energy efficiency are also usually raised, which partly determine the composition of the glazing: triple insulating glass unit (IGU) with inner safety laminated glass sheet. Therefore, the aim of the research was to investigate the structural sealed façade structure with triple IGU and to determine the effect of the thickness of ordinary and laminated glasses, their position in the IGU, the thickness of the gas cavities, and the mass of the structural frame on the sound insulation level of structural glazing. Experimental measurements of the sound insulation index of the investigated façade elements with IGU of various constructions were performed in an acoustic reverberation chamber according to standard procedures. The result of the study indicated that the use of the second laminated glass in a triple IGU is inefficient, the highest sound insulation indicators are achieved by increasing the thicknesses of the external glass sheet and the gas cavity; increasing the mass of the frame also has only little effect on the sound insulation of the structural glazing. Full article
(This article belongs to the Section Building Energy, Physics, Environment, and Systems)
Show Figures

Figure 1

16 pages, 4433 KB  
Article
PVB/ATO Nanocomposites for Glass Coating Applications: Effects of Nanoparticles on the PVB Matrix
by Silvia Pizzanelli, Claudia Forte, Simona Bronco, Tommaso Guazzini, Chiara Serraglini and Lucia Calucci
Coatings 2019, 9(4), 247; https://doi.org/10.3390/coatings9040247 - 12 Apr 2019
Cited by 13 | Viewed by 6611
Abstract
Films made of poly(vinyl butyral) (PVB) and antimony-doped tin oxide (ATO) nanoparticles (NPs), both uncoated and surface-modified with an alkoxysilane, were prepared by solution casting at filler volume fractions ranging from 0.08% to 4.5%. The films were characterized by standard techniques including transmission [...] Read more.
Films made of poly(vinyl butyral) (PVB) and antimony-doped tin oxide (ATO) nanoparticles (NPs), both uncoated and surface-modified with an alkoxysilane, were prepared by solution casting at filler volume fractions ranging from 0.08% to 4.5%. The films were characterized by standard techniques including transmission electron microscopy, thermogravimetric analysis and differential scanning calorimetry (DSC). In the polymeric matrix, the primary NPs (diameter ~10 nm) aggregate exhibiting different morphologies depending on the presence of the surface coating. Coated ATO NPs form spherical particles (with a diameter of 300–500 nm), whereas more elongated fractal structures (with a thickness of ~250 nm and length of tens of micrometers) are formed by uncoated NPs. The fraction of the polymer interacting with the NPs is always negligible. In agreement with this finding, DSC data did not reveal any rigid interface and 1H time domain nuclear magnetic resonance (NMR) and fast field-cycling NMR did not show significant differences in polymer dynamics among the different samples. The ultraviolet-visible-near infrared (UV-Vis-NIR) transmittance of the films decreased compared to pure PVB, especially in the NIR range. The solar direct transmittance and the light transmittance were extracted from the spectra according to CEN EN 410/2011 in order to test the performance of our films as plastic layers in laminated glass for glazing. Full article
Show Figures

Figure 1

24 pages, 7798 KB  
Article
Numerical Analysis and 1D/2D Sensitivity Study for Monolithic and Laminated Structural Glass Elements under Thermal Exposure
by Marcin Kozłowski, Chiara Bedon and Dániel Honfi
Materials 2018, 11(8), 1447; https://doi.org/10.3390/ma11081447 - 16 Aug 2018
Cited by 22 | Viewed by 6654
Abstract
Glass is largely used in architectural and engineering applications (i.e., buildings and vehicles) as a structural material, especially in the form of laminated glass (LG) sections. To achieve adequate and controlled safety levels in these applications, the well-known temperature-dependent behavior of viscoelastic interlayers [...] Read more.
Glass is largely used in architectural and engineering applications (i.e., buildings and vehicles) as a structural material, especially in the form of laminated glass (LG) sections. To achieve adequate and controlled safety levels in these applications, the well-known temperature-dependent behavior of viscoelastic interlayers for LG sections should be properly accounted for during the design process. Furthermore, the materials’ thermomechanical degradation with increases of temperature could severely affect the load-bearing performance of glass assemblies. In this context, uncoupled thermomechanical finite element (FE) numerical models could represent a robust tool and support for design engineers. Key input parameters and possible limits of the FE method, however, should be properly calibrated and assessed, so as to enable reliable estimations for the real behavior of glazing systems. In this paper, FE simulations are proposed for monolithic (MG) and LG specimens under radiant heating, based on one-dimensional (1D) and two-dimensional (2D) models. A special attention is focused on thermal effects, being representative of the first step for conventional uncoupled, thermomechanical analyses. Based on experimental results available in the literature, FE parametric studies are discussed, giving evidence of limits and issues due to several modeling assumptions. In particular, careful consideration is paid for various thermal material properties (conductivity, specific heat) and thermal boundaries (conductivity, emissivity), but also for other influencing parameters like the geometrical features of samples (thickness tolerances, cross-sectional properties, etc.), the composition of LG sections (interlayer type, thickness), the loading pattern (heat transfer distribution) and the presence of additional mechanical restraints (i.e., supports of different materials). Comparative FE results are hence critically discussed, highlighting the major effects of such influencing parameters. Full article
(This article belongs to the Special Issue Selected Papers from the 3rd International E-Conference on Materials)
Show Figures

Figure 1

20 pages, 9887 KB  
Review
Thermochromic Oxide-Based Thin Films and Nanoparticle Composites for Energy-Efficient Glazings
by Claes G. Granqvist and Gunnar A. Niklasson
Buildings 2017, 7(1), 3; https://doi.org/10.3390/buildings7010003 - 29 Dec 2016
Cited by 40 | Viewed by 10486
Abstract
Today’s advances in materials science and technology can lead to better buildings with improved energy efficiency and indoor conditions. Particular attention should be directed towards windows and glass facades—jointly known as “glazings”—since current practices often lead to huge energy expenditures related to excessive [...] Read more.
Today’s advances in materials science and technology can lead to better buildings with improved energy efficiency and indoor conditions. Particular attention should be directed towards windows and glass facades—jointly known as “glazings”—since current practices often lead to huge energy expenditures related to excessive inflow or outflow of energy which need to be balanced by energy-intensive cooling or heating. This review article outlines recent progress in thermochromics, i.e., it deals with materials whose optical properties are strongly dependent on temperature. In particular, we discuss oxide-based thin surface coatings (thin films) and nanoparticle composites which can be deposited onto glass and are able to regulate the throughput of solar energy while the luminous (visible) properties remain more or less unaltered. Another implementation embodies lamination materials incorporating thermochromic (TC) nanoparticles. The thin films and nanocomposites are based on vanadium dioxide (VO2), which is able to change its properties within a narrow temperature range in the vicinity of room temperature and either reflects or absorbs infrared light at elevated temperatures, whereas the reflectance or absorptance is much smaller at lower temperatures. The review outlines the state of the art for these thin films and nanocomposites with particular attention to recent developments that have taken place in laboratories worldwide. Specifically, we first set the scene by discussing environmental challenges and their relationship with TC glazings. Then enters VO2 and we present its key properties in thin-film form and as nanoparticles. The next part of the article gives perspectives on the manufacturing of these films and particles. We point out that the properties of pure VO2 may not be fully adequate for buildings and we elaborate how additives, antireflection layers, nanostructuring and protective over-coatings can be employed to yield improved performance and durability that make TC glazings of considerable interest for building-related applications. Finally, we briefly describe recent developments towards TC light scattering and draw some final conclusions. Full article
(This article belongs to the Special Issue Building Refurbishment and Energy Performance)
Show Figures

Figure 1

Back to TopTop