Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (26)

Search Parameters:
Keywords = in vivo dielectric properties

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
16 pages, 5574 KiB  
Article
Skin Hydration Monitoring Using a Microwave Sensor: Design, Fabrication, and In Vivo Analysis
by Shabbir Chowdhury, Amir Ebrahimi, Kamran Ghorbani and Francisco Tovar-Lopez
Sensors 2025, 25(11), 3445; https://doi.org/10.3390/s25113445 - 30 May 2025
Viewed by 858
Abstract
This article introduces a microwave sensor tailored for skin hydration monitoring. The design enables wireless operation by separating the sensing component from the reader, making it ideal for wearable devices like wristbands. The sensor consists of a semi-lumped LC resonator coupled to [...] Read more.
This article introduces a microwave sensor tailored for skin hydration monitoring. The design enables wireless operation by separating the sensing component from the reader, making it ideal for wearable devices like wristbands. The sensor consists of a semi-lumped LC resonator coupled to an inductive coil reader, where the capacitive part of the sensing tag is in contact with the skin. The variations in the skin hydration level alter the dielectric properties of the skin, which, in turn, modify the resonances of the LC resonator. Experimental in vivo measurements confirmed the sensor’s ability to distinguish between four hydration conditions: wet skin, skin treated with moisturizer, untreated dry skin, and skin treated with Vaseline, by measuring the resonance frequencies of the sensor. Measurement of the input reflection coefficient (S11) using a vector network analyzer (VNA) revealed distinct reflection poles and zeros for each condition, demonstrating the sensor’s effectiveness in detecting skin hydration levels. The sensing principle was analyzed using an equivalent circuit model and validated through measurements of a fabricated sensor prototype. The results confirm in vivo skin hydration monitoring by detecting frequency shifts in the reflection response within the 50–200 MHz range. The measurements and data analysis show less than 0.037% error in transmission zero (fz) together with less than 1.5% error in transmission pole (fp) while being used to detect skin hydration status on individual human subjects. The simplicity of the detection method, focusing on key frequency shifts, underscores the sensor’s potential as a practical and cost-effective solution for non-invasive skin hydration monitoring. This advancement holds significant potential for skincare and biomedical applications, enabling detection without complex signal processing. Full article
(This article belongs to the Section Wearables)
Show Figures

Figure 1

17 pages, 5905 KiB  
Article
An Improved Cole–Cole Model for Characterizing In Vivo Dielectric Properties of Lung Tissue at Different Tide Volumes: An Animal Study
by Yangchun Qin, Liang Zhang, Tixin Han, Yifan Liu, Xuechao Liu, Feng Fu, Hang Wang, Shuoyao Qu, Zhanqi Zhao, Lin Yang and Meng Dai
Bioengineering 2025, 12(5), 445; https://doi.org/10.3390/bioengineering12050445 - 24 Apr 2025
Viewed by 533
Abstract
Objective: The air content within the lungs directly influences the dielectric properties of lung tissue; however, previous studies were conducted under ex vivo conditions and without quantitatively controlling air volume. This study aims to develop an improved model using in vivo measurements to [...] Read more.
Objective: The air content within the lungs directly influences the dielectric properties of lung tissue; however, previous studies were conducted under ex vivo conditions and without quantitatively controlling air volume. This study aims to develop an improved model using in vivo measurements to accurately characterize the dielectric properties of rabbit lung tissue across various tidal volumes. Methods: In this study, six sets of different tidal volumes (30, 40, 50, 60, 70, 80 mL) were set in the frequency band of 100 MHz~1 GHz to analyze the trend of the dielectric properties, and the dielectric parameters were systematically constructed under the conditions of different tidal volumes. Results: It was found that the conductivity and permittivity of rabbit lung tissue showed a decreasing trend with increasing tidal volume in the measuring frequency band. The traditional Cole–Cole model has limitations in simulating the dielectric properties of in vivo lung tissues. Therefore, by refining and optimizing the model, this study successfully reduced the average error between the measured data and the model fitting to less than 5%. Conclusions: This study lays the groundwork for investigating the relationship between total air volume within the lungs and their dielectric properties in vivo. Full article
(This article belongs to the Section Biomedical Engineering and Biomaterials)
Show Figures

Figure 1

14 pages, 2897 KiB  
Article
New Concept of Colonoscopy Assisted by a Microwave-Based Accessory Device: First Clinical Experience
by Oswaldo Ortiz, Oriol Sendino, Silvia Rivadulla, Alejandra Garrido, Luz María Neira, Josep Sanahuja, Pilar Sesé, Marta Guardiola and Glòria Fernández-Esparrach
Cancers 2025, 17(7), 1073; https://doi.org/10.3390/cancers17071073 - 22 Mar 2025
Cited by 1 | Viewed by 692
Abstract
Background/Objectives: Colonoscopies have some limitations that result in a miss rate detection of polyps. Microwave imaging has been demonstrated to detect colorectal polyps based on their dielectric properties in synthetic phantoms, ex vivo tissues and in vivo animal models. This study aims [...] Read more.
Background/Objectives: Colonoscopies have some limitations that result in a miss rate detection of polyps. Microwave imaging has been demonstrated to detect colorectal polyps based on their dielectric properties in synthetic phantoms, ex vivo tissues and in vivo animal models. This study aims to evaluate, for the first time, the feasibility, safety and performance of microwave-based colonoscopy for diagnosis of polyps in real-time explorations in humans. Methods: This was a single-center, prospective, observational study. Patients referred for diagnostic colonoscopy were explored with a device with microwave antennas which was attached to the tip of a standard colonoscope. The primary outcomes were rate of cecal intubation, adverse events, mural injuries and performance metrics for the detection of polyps. Secondary outcomes were the following: patients’ subjective feedback, procedural time and perception of difficulty according to the endoscopist. Results: Fifteen patients were enrolled. Cecal intubation rate was 100%, with a mean time of 12.7 ± 4.9 min (range 4–22). Use of the device did not affect the endoscopic image, and polypectomy was successfully performed in all cases. In on scale from zero (not difficult) to four (very difficult), the maneuverability during the insertion was considered ≤2 in the 86.7% (13/15) of colonoscopies. Only 16 incidents were reported in 14 patients: 11 (67%) superficial hematomas, 2 minor rectal bleedings, 1 anal fissure, 1 rhinorrhea and 1 headache. Most of the patients (94%) reported no discomfort or minimal discomfort before discharge (Gloucester score 1 and 2, respectively). In the six patients with 23 polyps used for the performance analysis, the sensitivity and specificity were 86.9% and 72.0%, respectively. Conclusions: microwave-based colonoscopy is safe and feasible and has the potential to detect polyps in real colonoscopies. Full article
(This article belongs to the Section Methods and Technologies Development)
Show Figures

Figure 1

14 pages, 5030 KiB  
Article
Reconstruction of the Permittivity of Ex Vivo Animal Tissues in the Frequency Range 1–20 GHz Using a Water-Based Dielectric Model
by Flavia Liporace, Gianluca Ciarleglio, Maria Gabriella Santonicola and Marta Cavagnaro
Sensors 2024, 24(16), 5338; https://doi.org/10.3390/s24165338 - 18 Aug 2024
Viewed by 1306
Abstract
Several medical techniques are based on the application of electromagnetic fields (EMFs) on the human body with therapeutic and/or diagnostic aims. The response of human tissues to the applied EMF is mediated by the tissues’ dielectric properties, which must therefore be characterized at [...] Read more.
Several medical techniques are based on the application of electromagnetic fields (EMFs) on the human body with therapeutic and/or diagnostic aims. The response of human tissues to the applied EMF is mediated by the tissues’ dielectric properties, which must therefore be characterized at the frequencies of the considered technique. Due to the heterogeneity and complexity of biological tissues, it is necessary to know their properties in vivo for the specific condition of interest. Traditional techniques for the dielectric characterization of biological tissues are invasive and, as such, not adoptable for this aim. Accordingly, alternative sensors and/or sensing methods are needed. Recently, a new wideband spectroscopy technique was proposed, based on quantities derived from the Magnetic Resonance (MRI) signal. Among these quantities, the water content was proposed to evaluate the dielectric properties at frequencies around a few GHz. This work verifies the possibility of deriving tissues’ dielectric properties in the frequency range of 1–20 GHz based on knowledge of the water content. The water content was retrieved through a dehydration procedure for five different ex vivo tissues. The achieved results were compared with references from the literature. Full article
(This article belongs to the Section Biomedical Sensors)
Show Figures

Figure 1

14 pages, 2380 KiB  
Article
Determining of Ablation Zone in Ex Vivo Bovine Liver Using Time-Shift Measurements
by Mohamed Lamhamdi, Ali Esmaeili, Kiyan Layes, Zakaria El Maaroufi, Georg Rose, Andreas Brensing and Bernd Schweizer
Cancers 2023, 15(21), 5230; https://doi.org/10.3390/cancers15215230 - 31 Oct 2023
Cited by 5 | Viewed by 1890
Abstract
This study presents a measurement principle for determining the size of the ablation zone in MWA, which could ultimately form an alternative to more expensive monitoring approaches like CT. The measurement method is based on a microwave transmission measurement. A MWA is performed [...] Read more.
This study presents a measurement principle for determining the size of the ablation zone in MWA, which could ultimately form an alternative to more expensive monitoring approaches like CT. The measurement method is based on a microwave transmission measurement. A MWA is performed experimentally on ex vivo bovine liver to determine the ablation zone. This setup uses a custom slot applicator performing the MWA at an operating frequency of 2.45 GHz and a custom bowtie antenna measuring the waves transmitted from the applicator. Furthermore, a custom measurement probe is used to determine the dielectric properties. A time-shift analysis is used to determine the radial extent of the ablation zone. Several measurements are carried out with a power of 50 W for 10 min to show the reproducibility. The results show that this method can provide reproducible outcomes to determine the ablation zone with a maximum error of 4.11%. Full article
(This article belongs to the Special Issue Local Ablation Therapy in Liver Cancer)
Show Figures

Figure 1

27 pages, 18187 KiB  
Article
Histology-Validated Dielectric Characterisation of Lung Carcinoma Tissue for Microwave Thermal Ablation Applications
by Laura Farina, Giuseppe Ruvio, Ramadan Shatwan, Aliaa Shalaby, Martin O’Halloran, Alexandra White, Alan Soo, David Breen, Aoife Lowery and Anne Marie Quinn
Cancers 2023, 15(14), 3738; https://doi.org/10.3390/cancers15143738 - 23 Jul 2023
Cited by 11 | Viewed by 1967
Abstract
Microwave thermal ablation is a promising emerging treatment for early-stage lung cancer. Applicator design optimisation and treatment planning rely on accurate knowledge of dielectric tissue properties. Limited dielectric data are available in the literature for human lung tissue and pulmonary tumours. In this [...] Read more.
Microwave thermal ablation is a promising emerging treatment for early-stage lung cancer. Applicator design optimisation and treatment planning rely on accurate knowledge of dielectric tissue properties. Limited dielectric data are available in the literature for human lung tissue and pulmonary tumours. In this work, neoplastic and non-neoplastic lung dielectric properties are characterised and correlated with gross and histological morphology. Fifty-six surgical specimens were obtained from twelve patients undergoing lung resection for lung cancer in University Hospital of Galway, Ireland. Dielectric spectroscopy in the microwave frequency range (500 MHz–8.5 GHz) was performed on the ex vivo lung specimens with the open-ended coaxial probe technique (in the Department of Pathology). Dielectric data were analysed and correlated with the tissue histology. The dielectric properties of twelve lung tumours (67% non-small cell carcinoma (NSCC)) and uninvolved lung parenchyma were obtained. The values obtained from the neoplastic lung specimens (relative permittivity: 52.0 ± 5.4, effective conductivity: 1.9 ± 0.2 S/m, at 2.45 GHz) were on average twice the value of the non-neoplastic lung specimens (relative permittivity: 28.3 ± 6.7, effective conductivity: 1.0 ± 0.3 S/m, at 2.45 GHz). Dense fibrosis was comparable with tumour tissue (relative permittivity 49.3 ± 4.6, effective conductivity: 1.8 ± 0.1 S/m, at 2.45 GHz). Full article
Show Figures

Figure 1

32 pages, 1443 KiB  
Article
Erythrocyte Membrane Biophysical Changes Mediated by Pooled Immunoglobulin G and Hematin: Electrokinetic and Lipid Peroxidation Studies
by Virjinia Doltchinkova, Meglena Kitanova, Rumen Nikolov, Angelina Stoyanova-Ivanova, Ognyan Petkov, Yoana Dikova and Victoria Vitkova
Membranes 2023, 13(3), 281; https://doi.org/10.3390/membranes13030281 - 27 Feb 2023
Cited by 1 | Viewed by 2288
Abstract
Pooled Immunoglobulin G (IgG), hematin and the membrane-disruptive amphipathic peptide melittin have received attention as powerful biomacromolecules for biomedical and pharmacology applications. Their action on surface properties, oxidation status and epifluorescence properties measured in vitro provide useful information about the functional activity of [...] Read more.
Pooled Immunoglobulin G (IgG), hematin and the membrane-disruptive amphipathic peptide melittin have received attention as powerful biomacromolecules for biomedical and pharmacology applications. Their action on surface properties, oxidation status and epifluorescence properties measured in vitro provide useful information about the functional activity of upper biomacromolecules in erythrocytes in vivo. The hemolysis of erythrocyte membranes, as well as changes in hematocrit and the morphology of erythrocytes, was investigated here via fluorescence microscopy using FITC-concanavalin A binding to cells. The effect of melittin on the membrane capacitance and resistance of model lipid bilayers was probed via electrochemical impedance spectroscopy. Lipid bilayer capacitance was higher in the presence of 0.10 g/L melittin compared to that in the control, which is likely related to bilayer thinning and alterations of the dielectric permittivity of melittin-treated membranes. The biomolecule interactions with red blood cells were probed in physiological media in which the surface of erythrocyte membranes was negatively charged. Surface parameters of erythrocytes are reported upon IgG/hematin and IgG/melittin treatment. Pooled IgG in the presence of melittin, preincubated IgG/hematin preparations promoted a significant decrease in the electrokinetic potential of erythrocytes (Rh-positive). A malondialdehyde (MDA) assay revealed a high rate of lipid peroxidation in erythrocytes treated with IgG/hematin or IgG/melittin preparations. This finding might be a result of pooled IgG interactions with the hematin molecule and the subsequent conformational changes in the protein molecule altering the electrokinetic properties of the erythrocyte membrane related to the Rh group type of erythrocytes. The pooled IgG and hematin are reported to have important consequences for the biophysical understanding of the immunopathological mechanisms of inflammatory, autoimmune and antibody-mediated pathological processes. Full article
(This article belongs to the Special Issue Biological Membrane and Bioactive Compounds Interactions)
Show Figures

Figure 1

20 pages, 5250 KiB  
Article
Physio-Chemical and Biological Characterization of Novel HPC (Hydroxypropylcellulose):HAP (Hydroxyapatite):PLA (Poly Lactic Acid) Electrospun Nanofibers as Implantable Material for Bone Regenerative Application
by S. Mary Stella, T. M. Sridhar, R. Ramprasath, Jolius Gimbun and U. Vijayalakshmi
Polymers 2023, 15(1), 155; https://doi.org/10.3390/polym15010155 - 29 Dec 2022
Cited by 15 | Viewed by 3267
Abstract
The research on extracellular matrix (ECM) is new and developing area that covers cell proliferation and differentiation and ensures improved cell viability for different biomedical applications. Extracellular matrix not only maintains biological functions but also exhibits properties such as tuned or natural material [...] Read more.
The research on extracellular matrix (ECM) is new and developing area that covers cell proliferation and differentiation and ensures improved cell viability for different biomedical applications. Extracellular matrix not only maintains biological functions but also exhibits properties such as tuned or natural material degradation within a given time period, active cell binding and cellular uptake for tissue engineering applications. The principal objective of this study is classified into two categories. The first phase is optimization of various electrospinning parameters with different concentrations of HAP-HPC/PLA(hydroxyapatite-hydroxypropylcellulose/poly lactic acid). The second phase is in vitro biological evaluation of the optimized mat using MTT (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide) assay for bone regeneration applications. Conductivity and dielectric constant were optimized for the production of thin fiber and bead free nanofibrous mat. With this optimization, the mechanical strength of all compositions was found to be enhanced, of which the ratio of 70:30 hit a maximum of 9.53 MPa (megapascal). Cytotoxicity analysis was completed for all the compositions on MG63 cell lines for various durations and showed maximum cell viability on 70:30 composition for more than 48 hrs. Hence, this investigation concludes that the optimized nanofibrous mat can be deployed as an ideal material for bone regenerative applications. In vivo study confirms the HAP-HPC-PLA sample shows more cells and bone formation at 8 weeks than 4 weeks. Full article
(This article belongs to the Special Issue Biomaterials for Tissue Engineering and Regeneration)
Show Figures

Graphical abstract

13 pages, 2983 KiB  
Article
MiWEndo: Evaluation of a Microwave Colonoscopy Algorithm for Early Colorectal Cancer Detection in Ex Vivo Human Colon Models
by Marta Guardiola, Walid Dghoughi, Roberto Sont, Alejandra Garrido, Sergi Marcoval, Luz María Neira, Ignasi Belda and Glòria Fernández-Esparrach
Sensors 2022, 22(13), 4902; https://doi.org/10.3390/s22134902 - 29 Jun 2022
Cited by 6 | Viewed by 2684
Abstract
This study assesses the efficacy of detecting colorectal cancer precursors or polyps in an ex vivo human colon model with a microwave colonoscopy algorithm. Nowadays, 22% of polyps go undetected with conventional colonoscopy, and the risk of cancer after a negative colonoscopy can [...] Read more.
This study assesses the efficacy of detecting colorectal cancer precursors or polyps in an ex vivo human colon model with a microwave colonoscopy algorithm. Nowadays, 22% of polyps go undetected with conventional colonoscopy, and the risk of cancer after a negative colonoscopy can be up to 7.9%. We developed a microwave colonoscopy device that consists of a cylindrical ring-shaped switchable microwave antenna array that can be attached to the tip of a conventional colonoscope as an accessory. The accessory is connected to an external unit that allows successive measurements of the colon and processes the measurements with a microwave imaging algorithm. An acoustic signal is generated when a polyp is detected. Fifteen ex vivo freshly excised human colons with cancer (n = 12) or polyps (n = 3) were examined with the microwave-assisted colonoscopy system simulating a real colonoscopy exploration. After the experiment, the dielectric properties of the specimens were measured with a coaxial probe and the samples underwent a pathology analysis. The results show that all the neoplasms were detected with a sensitivity of 100% and specificity of 87.4%. Full article
Show Figures

Figure 1

13 pages, 2967 KiB  
Article
Controlled Measurement Setup for Ultra-Wideband Dielectric Modeling of Muscle Tissue in 20–45 °C Temperature Range
by Gertjan Maenhout, Tomislav Markovic and Bart Nauwelaers
Sensors 2021, 21(22), 7644; https://doi.org/10.3390/s21227644 - 17 Nov 2021
Cited by 3 | Viewed by 2834
Abstract
In order to design electromagnetic applicators for diagnostic and therapeutic applications, an adequate dielectric tissue model is required. In addition, tissue temperature will heavily influence the dielectric properties and the dielectric model should, thus, be extended to incorporate this temperature dependence. Thus, this [...] Read more.
In order to design electromagnetic applicators for diagnostic and therapeutic applications, an adequate dielectric tissue model is required. In addition, tissue temperature will heavily influence the dielectric properties and the dielectric model should, thus, be extended to incorporate this temperature dependence. Thus, this work has a dual purpose. Given the influence of temperature, dehydration, and probe-to-tissue contact pressure on dielectric measurements, this work will initially present the first setup to actively control and monitor the temperature of the sample, the dehydration rate of the investigated sample, and the applied probe-to-tissue contact pressure. Secondly, this work measured the dielectric properties of porcine muscle in the 0.5–40 GHz frequency range for temperatures from 20 °C to 45 °C. Following measurements, a single-pole Cole–Cole model is presented, in which the five Cole–Cole parameters (ϵ, σs, Δϵ, τ, and α) are given by a first order polynomial as function of tissue temperature. The dielectric model closely agrees with the limited dielectric models known in literature for muscle tissue at 37 °C, which makes it suited for the design of in vivo applicators. Furthermore, the dielectric data at 41–45 °C is of great importance for the design of hyperthermia applicators. Full article
Show Figures

Figure 1

13 pages, 3470 KiB  
Article
Application of Machine Learning to Predict Dielectric Properties of In Vivo Biological Tissue
by Branislav Gerazov, Daphne Anne Caligari Conti, Laura Farina, Lourdes Farrugia, Charles V. Sammut, Pierre Schembri Wismayer and Raquel C. Conceição
Sensors 2021, 21(20), 6935; https://doi.org/10.3390/s21206935 - 19 Oct 2021
Cited by 5 | Viewed by 2787
Abstract
In this paper we revisited a database with measurements of the dielectric properties of rat muscles. Measurements were performed both in vivo and ex vivo; the latter were performed in tissues with varying levels of hydration. Dielectric property measurements were performed with an [...] Read more.
In this paper we revisited a database with measurements of the dielectric properties of rat muscles. Measurements were performed both in vivo and ex vivo; the latter were performed in tissues with varying levels of hydration. Dielectric property measurements were performed with an open-ended coaxial probe between the frequencies of 500 MHz and 50 GHz at a room temperature of 25 °C. In vivo dielectric properties are more valuable for creating realistic electromagnetic models of biological tissue, but these are more difficult to measure and scarcer in the literature. In this paper, we used machine learning models to predict the in vivo dielectric properties of rat muscle from ex vivo dielectric property measurements for varying levels of hydration. We observed promising results that suggest that our model can make a fair estimation of in vivo properties from ex vivo properties. Full article
Show Figures

Graphical abstract

18 pages, 27576 KiB  
Article
Experimental Validation of a Microwave System for Brain Stroke 3-D Imaging
by David O. Rodriguez-Duarte, Jorge A. Tobon Vasquez, Rosa Scapaticci, Giovanna Turvani, Marta Cavagnaro, Mario R. Casu, Lorenzo Crocco and Francesca Vipiana
Diagnostics 2021, 11(7), 1232; https://doi.org/10.3390/diagnostics11071232 - 8 Jul 2021
Cited by 46 | Viewed by 4726
Abstract
This paper experimentally validates the capability of a microwave prototype device to localize hemorrhages and ischemias within the brain as well as proposes an innovative calibration technique based on the measured data. In the reported experiments, a 3-D human-like head phantom is considered, [...] Read more.
This paper experimentally validates the capability of a microwave prototype device to localize hemorrhages and ischemias within the brain as well as proposes an innovative calibration technique based on the measured data. In the reported experiments, a 3-D human-like head phantom is considered, where the brain is represented either with a homogeneous liquid mimicking brain dielectric properties or with ex vivo calf brains. The microwave imaging (MWI) system works at 1 GHz, and it is realized with a low-complexity architecture formed by an array of twenty-four printed monopole antennas. Each antenna is embedded into the “brick” of a semi-flexible dielectric matching medium, and it is positioned conformal to the head upper part. The imaging algorithm exploits a differential approach and provides 3-D images of the brain region. It employs the singular value decomposition of the discretized scattering operator obtained via accurate numerical models. The MWI system analysis shows promising reconstruction results and extends the device validation. Full article
(This article belongs to the Special Issue Electromagnetic Imaging for a Novel Generation of Medical Devices)
Show Figures

Figure 1

19 pages, 4356 KiB  
Article
Towards Accurate Microwave Characterization of Tissues: Sensing Depth Analysis of Open-Ended Coaxial Probes with Ex Vivo Rat Breast and Skin Tissues
by Cemanur Aydinalp, Sulayman Joof and Tuba Yilmaz
Diagnostics 2021, 11(2), 338; https://doi.org/10.3390/diagnostics11020338 - 18 Feb 2021
Cited by 9 | Viewed by 4170
Abstract
Dielectric properties of biological materials are commonly characterized with open-ended coaxial probes due to the broadband and non-destructive measurement capabilities. Recently, potential diagnostics applications of the technique have been investigated. Although the technique can successfully classify the tissues with different dielectric properties, the [...] Read more.
Dielectric properties of biological materials are commonly characterized with open-ended coaxial probes due to the broadband and non-destructive measurement capabilities. Recently, potential diagnostics applications of the technique have been investigated. Although the technique can successfully classify the tissues with different dielectric properties, the classification accuracy can be improved for tissues with similar dielectric properties. Increase in classification accuracy can be achieved by addressing the error sources. One well-known error source contributing to low measurement accuracy is tissue heterogeneity. To mitigate this error source, there is a need define the probe sensing depth. Such knowledge can enable application-specific probe selection or design. The sensing depth can also be used as an input to the classification algorithms which can potentially improve the tissue classification accuracy. Towards this goal, this work investigates the sensing depth of a commercially available 2.2 mm aperture diameter probe with double-layered configurations using ex vivo rat breast and skin tissues. It was concluded that the dielectric property contrast between the heterogeneous tissue components has an effect on the sensing depth. Also, a membrane layer (between 0.4–0.8 mm thickness) on the rat wet skin tissue and breast tissue will potentially affect the dielectric property measurement results by 52% to 84%. Full article
(This article belongs to the Special Issue Electromagnetic Imaging for a Novel Generation of Medical Devices)
Show Figures

Figure 1

16 pages, 5285 KiB  
Article
Experimental Validation on Tissue-Mimicking Phantoms of Millimeter-Wave Imaging for Breast Cancer Detection
by Simona Di Meo, Giulia Matrone and Marco Pasian
Appl. Sci. 2021, 11(1), 432; https://doi.org/10.3390/app11010432 - 4 Jan 2021
Cited by 32 | Viewed by 3868
Abstract
Breast cancer is one of the leading causes of cancer death among women; to decrease the death rate for this disease, early detection plays a key role. Recently, microwave imaging systems have been proposed as an alternative to the current techniques, but they [...] Read more.
Breast cancer is one of the leading causes of cancer death among women; to decrease the death rate for this disease, early detection plays a key role. Recently, microwave imaging systems have been proposed as an alternative to the current techniques, but they suffer from poor resolution due to the low frequencies involved. In this paper, for the first time, an innovative millimeter-wave imaging system for early-stage breast cancer detection is proposed and experimentally verified on different breast phantoms. This has the potential to achieve superior resolution for breasts with a high volumetric percentage of adipose tissue, and the merit to overcome the common misconception that millimeter-waves cannot achieve useful penetration depths for biological applications. Three phantoms were prepared according to the dielectric properties of human breast ex vivo tissues in the frequency range [0.5–50] GHz. Two cylindrical inclusions made by water and gelatin or agar, mimicking dielectric properties of neoplastic tissues, were embedded in the phantom at different depths up to 3 cm. Two double ridge waveguides, with mono-modal frequency band equal to [18–40] GHz, were used to synthetize a linear array of 24 elements in 28 positions, acquiring signals with a Vector Network Analyzer. The images were reconstructed by applying the Delay and Sum algorithm to calibrated data. The feasibility of a new imaging system with a central working frequency of about 30 GHz is experimentally demonstrated for the first time, and a target detection capability up to 3 cm within the phantom is shown. The presented results pave the way for a possible use of millimeter-waves to image non-superficial neoplasms in the breast. Full article
Show Figures

Graphical abstract

15 pages, 4514 KiB  
Article
A Pilot Study of the Impact of Microwave Ablation on the Dielectric Properties of Breast Tissue
by Luz Maria Neira, R. Owen Mays, James F. Sawicki, Amanda Schulman, Josephine Harter, Lee G. Wilke, Nader Behdad, Barry D. Van Veen and Susan C. Hagness
Sensors 2020, 20(19), 5698; https://doi.org/10.3390/s20195698 - 6 Oct 2020
Cited by 9 | Viewed by 3518
Abstract
Percutaneous microwave ablation (MWA) is a promising technology for patients with breast cancer, as it may help treat individuals who have less aggressive cancers or do not respond to targeted therapies in the neoadjuvant or pre-surgical setting. In this study, we investigate changes [...] Read more.
Percutaneous microwave ablation (MWA) is a promising technology for patients with breast cancer, as it may help treat individuals who have less aggressive cancers or do not respond to targeted therapies in the neoadjuvant or pre-surgical setting. In this study, we investigate changes to the microwave dielectric properties of breast tissue that are induced by MWA. While similar changes have been characterized for relatively homogeneous tissues, such as liver, those prior results are not directly translatable to breast tissue because of the extreme tissue heterogeneity present in the breast. This study was motivated, in part by the expectation that the changes in the dielectric properties of the microwave antenna’s operation environment will be impacted by tissue composition of the ablation target, which includes not only the tumor, but also its margins. Accordingly, this target comprises a heterogeneous mix of malignant, healthy glandular, and adipose tissue. Therefore, knowledge of MWA impact on breast dielectric properties is essential for the successful development of MWA systems for breast cancer. We performed ablations in 14 human ex-vivo prophylactic mastectomy specimens from surgeries that were conducted at the UW Hospital and monitored the temperature in the vicinity of the MWA antenna during ablation. After ablation we measured the dielectric properties of the tissue and analyzed the tissue samples to determine both the tissue composition and the extent of damage due to the ablation. We observed that MWA induced cell damage across all tissue compositions, and found that the microwave frequency-dependent relative permittivity and conductivity of damaged tissue are lower than those of healthy tissue, especially for tissue with high fibroglandular content. The results provide information for future developments on breast MWA systems. Full article
Show Figures

Figure 1

Back to TopTop