Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (21)

Search Parameters:
Keywords = four-dimensional (4D) flow magnetic resonance

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
13 pages, 2985 KiB  
Review
Four-Dimensional Flow in Fontan Patients: Advanced Haemodynamic Assessment
by Dominik Daniel Gabbert, Anselm Sebastian Uebing and Inga Voges
J. Clin. Med. 2025, 14(11), 3801; https://doi.org/10.3390/jcm14113801 - 29 May 2025
Viewed by 484
Abstract
Staged palliation with the creation of a Fontan circulation is the standard surgical approach in patients with a single ventricle. The Fontan circulation is a complex circuit that is associated with various complications that may present early or later in life and can [...] Read more.
Staged palliation with the creation of a Fontan circulation is the standard surgical approach in patients with a single ventricle. The Fontan circulation is a complex circuit that is associated with various complications that may present early or later in life and can limit life quality and expectancy. In this context, a good understanding of the Fontan physiology is important to improve outcomes for single-ventricle patients. Cardiovascular magnetic resonance (CMR) is recommended for the long-term follow-up of Fontan patients, as it provides functional and haemodynamic information. Four-dimensional (4D) Flow MRI is a time-resolved, three-dimensional, velocity-encoded cardiovascular magnetic resonance technique that is increasingly used in Fontan patients because it not only enables measuring blood flow within a three-dimensional (3D) volume, but also allows for assessing more advanced haemodynamic parameters that may help in understanding the Fontan physiology and pathophysiology. Furthermore, 4D Flow is used for image-based simulations using computational fluid dynamics. In this review, we provide an overview of the use of cardiovascular magnetic resonance flow assessment, with a focus on four-dimensional flow (‘4D Flow’). Full article
Show Figures

Figure 1

17 pages, 2270 KiB  
Article
Four-Dimensional Magnetic Resonance Pulmonary Flow Imaging for Assessing Pulmonary Vasculopathy in Patients with Postcapillary Pulmonary Hypertension
by Jorge Nuche, Inés Ponz, Violeta Sánchez Sánchez, Javier Bóbeda, Ángel Gaitán, Karen López-Linares, María Dolores García-Cosío, Fernando Sarnago Cebada, Javier Sánchez González, Fernando Arribas Ynsaurriaga, Jesús Ruíz-Cabello, Borja Ibáñez and Juan F. Delgado
J. Clin. Med. 2025, 14(3), 929; https://doi.org/10.3390/jcm14030929 - 31 Jan 2025
Cited by 2 | Viewed by 881
Abstract
Background: Noninvasive techniques for diagnosing combined postcapillary pulmonary hypertension (CpcPH) are unavailable. Objective: To assess the diagnostic performance of cardiac magnetic resonance (CMR)-based four-dimensional (4D)-flow analysis in identifying CpcPH. Methods: Prospective observational study of heart failure (HF) patients with suspected [...] Read more.
Background: Noninvasive techniques for diagnosing combined postcapillary pulmonary hypertension (CpcPH) are unavailable. Objective: To assess the diagnostic performance of cardiac magnetic resonance (CMR)-based four-dimensional (4D)-flow analysis in identifying CpcPH. Methods: Prospective observational study of heart failure (HF) patients with suspected pulmonary hypertension (PH) who underwent simultaneous CMR and right heart catheterization. The 4D-flow biomarkers were calculated using an automatic pipeline. A predictive model including 4D-flow biomarkers associated with CpcPH with a p-value < 0.20 was built to determine the diagnostic performance of 4D-flow analysis to identify CpcPH. Results: A total of 46 HF patients (55.4 ± 14 years, 63% male) with confirmed PH (19 [41%] isolated postcapillary PH [IpcPH], 27 [59%] CpcPH) were included. No differences were found in baseline characteristics, echocardiography, or CMR anatomical and functional parameters, except for a higher Doppler-estimated systolic pulmonary pressure and larger pulmonary artery in CpcPH patients. The 4D-flow CMR analysis was performed in 31 patients (67%). The maximal peak velocity (67.1 [62.2–77.5] cm/s—IpcPH vs. 58.2 [45.8–66.0] cm/s—CpcPH; p = 0.021) and maximal helicity (339.9 [290.0–391.8]) cm/s2—IpcPH vs. 226.0 (173.5–343.7) cm/s2—CpcPH; p = 0.026) were significantly lower in patients with CpcPH. A maximal multivariable model including sex, maximal average, and peak velocities, Reynolds number, flow rate, and helicity showed fair diagnostic performance (area under the curve: 0.768 [95%-CI: 0.572–0.963]; sensitivity: 100%; specificity: 55%). Conclusions: In HF patients with PH, 4D-flow-derived maximal peak velocity and maximal helicity were significantly lower in CpcPH patients. A multiparametric model including maximal 4D-flow-derived biomarkers showed good diagnostic performance for identifying CpcPH. Full article
Show Figures

Figure 1

20 pages, 4029 KiB  
Study Protocol
Four-Dimensional Flow MRI for Cardiovascular Evaluation (4DCarE): A Prospective Non-Inferiority Study of a Rapid Cardiac MRI Exam: Study Protocol and Pilot Analysis
by Jiaxing Jason Qin, Mustafa Gok, Alireza Gholipour, Jordan LoPilato, Max Kirkby, Christopher Poole, Paul Smith, Rominder Grover and Stuart M. Grieve
Diagnostics 2024, 14(22), 2590; https://doi.org/10.3390/diagnostics14222590 - 18 Nov 2024
Viewed by 1486
Abstract
Background: Accurate measurements of flow and ventricular volume and function are critical for clinical decision-making in cardiovascular medicine. Cardiac magnetic resonance (CMR) is the current gold standard for ventricular functional evaluation but is relatively expensive and time-consuming, thus limiting the scale of clinical [...] Read more.
Background: Accurate measurements of flow and ventricular volume and function are critical for clinical decision-making in cardiovascular medicine. Cardiac magnetic resonance (CMR) is the current gold standard for ventricular functional evaluation but is relatively expensive and time-consuming, thus limiting the scale of clinical applications. New volumetric acquisition techniques, such as four-dimensional flow (4D-flow) and three-dimensional volumetric cine (3D-cine) MRI, could potentially reduce acquisition time without loss in accuracy; however, this has not been formally tested on a large scale. Methods: 4DCarE (4D-flow MRI for cardiovascular evaluation) is a prospective, multi-centre study designed to test the non-inferiority of a compressed 20 min exam based on volumetric CMR compared with a conventional CMR exam (45–60 min). The compressed exam utilises 4D-flow together with a single breath-hold 3D-cine to provide a rapid, accurate quantitative assessment of the whole heart function. Outcome measures are (i) flow and chamber volume measurements and (ii) overall functional evaluation. Secondary analyses will explore clinical applications of 4D-flow-derived parameters, including wall shear stress, flow kinetic energy quantification, and vortex analysis in large-scale cohorts. A target of 1200 participants will enter the study across three sites. The analysis will be performed at a single core laboratory site. Pilot Results: We present a pilot analysis of 196 participants comparing flow measurements obtained by 4D-flow and conventional 2D phase contrast, which demonstrated moderate–good consistency in ascending aorta and main pulmonary artery flow measurements between the two techniques. Four-dimensional flow underestimated the flow compared with 2D-PC, by approximately 3 mL/beat in both vessels. Conclusions: We present the study protocol of a prospective non-inferiority study of a rapid cardiac MRI exam compared with conventional CMR. The pilot analysis supports the continuation of the study. Study Registration: This study is registered with the Australia and New Zealand Clinical Trials Registry (Registry number ACTRN12622000047796, Universal Trial Number: U1111-1270-6509, registered 17 January 2022—Retrospectively registered). Full article
Show Figures

Figure 1

26 pages, 7939 KiB  
Article
Role of Non-Invasive Hemodynamic Forces through Four-Dimensional-Flow Magnetic Resonance Imaging (4D-Flow MRI) in Evaluating Mitral Regurgitation with Preserved Ejection Fraction: Seeking Novel Biomarkers
by Monisha Ghosh Srabanti, Corey Adams, Lyes Kadem and Julio Garcia
Appl. Sci. 2024, 14(19), 8577; https://doi.org/10.3390/app14198577 - 24 Sep 2024
Viewed by 1735
Abstract
Mitral regurgitation (MR) is the systolic retrograde flow from the left ventricle (LV) to the left atrium. Despite the recognized importance of hemodynamic force (HDF) in cardiology, its exploration in MR has been limited. Therefore, we aimed to explore non-invasively assessed HDF as [...] Read more.
Mitral regurgitation (MR) is the systolic retrograde flow from the left ventricle (LV) to the left atrium. Despite the recognized importance of hemodynamic force (HDF) in cardiology, its exploration in MR has been limited. Therefore, we aimed to explore non-invasively assessed HDF as a novel biomarker for evaluating MR utilizing 4D-flow MRI. The study cohort comprised 15 healthy controls (19–61 years, 53% men) and 26 MR patients with preserved ejection fraction (EF) (33–75 years, trivial–severe, 54% men). The HDF analysis involved the semi-automatic calculation of systolic–diastolic root mean square (RMS), average, and transverse/longitudinal ratio across three directions (S-L: septal–lateral, I-A: inferior–anterior, and B-A: basal–apical) using Segment, v2.2 R6410 (Lund, Sweden, Medviso). A noticeable trend shift emerged in HDF as the MR severity increased (p-value < 0.05). The MR severity demonstrated a noteworthy correlation with systolic RMS B-A, average B-A, diastolic average B-A, systolic average S-L, B-A, and systolic–diastolic ratio (rho = 0.621, 0.457, 0.317, 0.318, 0.555, −0.543, −0.35, respectively; p-value < 0.05). HDF significantly correlated with LV function (end-diastolic volume, end-systolic volume, EF, and mass; p-value < 0.05). Systolic RMS B-A and diastolic RMS S-L emerged as significant predictors of MR (Beta, 95% CI [3.253, 1.204–5.301], [5.413, 0.227–10.6], p-value < 0.05). This study emphasizes HDF as a potential hemodynamic biomarker for evaluating MR. Full article
Show Figures

Figure 1

20 pages, 10264 KiB  
Review
Importance of Cardiovascular Magnetic Resonance Applied to Congenital Heart Diseases in Pediatric Age: A Narrative Review
by Sara Moscatelli, Alice Pozza, Isabella Leo, Jessica Ielapi, Alessandra Scatteia, Sofia Piana, Annachiara Cavaliere, Elena Reffo and Giovanni Di Salvo
Children 2024, 11(7), 878; https://doi.org/10.3390/children11070878 - 19 Jul 2024
Cited by 5 | Viewed by 3202
Abstract
Congenital heart diseases (CHDs) represent a heterogeneous group of congenital defects, with high prevalence worldwide. Non-invasive imaging is essential to guide medical and surgical planning, to follow the patient over time in the evolution of the disease, and to reveal potential complications of [...] Read more.
Congenital heart diseases (CHDs) represent a heterogeneous group of congenital defects, with high prevalence worldwide. Non-invasive imaging is essential to guide medical and surgical planning, to follow the patient over time in the evolution of the disease, and to reveal potential complications of the chosen treatment. The application of cardiac magnetic resonance imaging (CMRI) in this population allows for obtaining detailed information on the defects without the necessity of ionizing radiations. This review emphasizes the central role of CMR in the overall assessment of CHDs, considering also the limitations and challenges of this imaging technique. CMR, with the application of two-dimensional (2D) and tri-dimensional (3D) steady-state free precession (SSFP), permits the obtaining of very detailed and accurate images about the cardiac anatomy, global function, and volumes’ chambers, giving essential information in the intervention planning and optimal awareness of the postoperative anatomy. Nevertheless, CMR supplies tissue characterization, identifying the presence of fat, fibrosis, or oedema in the myocardial tissue. Using a contrast agent for angiography sequences or 2D/four-dimensional (4D) flows offers information about the vascular, valvular blood flow, and, in general, the cardiovascular system hemodynamics. Furthermore, 3D SSFP CMR acquisitions allow the identification of coronary artery abnormalities as an alternative to invasive angiography and cardiovascular computed tomography (CCT). However, CMR requires expertise in CHDs, and it can be contraindicated in patients with non-conditional devices. Furthermore, its relatively longer acquisition time and the necessity of breath-holding may limit its use, particularly in children under eight years old, sometimes requiring anesthesia. The purpose of this review is to elucidate the application of CMR during the pediatric age. Full article
(This article belongs to the Section Pediatric Cardiology)
Show Figures

Figure 1

15 pages, 10190 KiB  
Article
Machine Learning-Based Segmentation of the Thoracic Aorta with Congenital Valve Disease Using MRI
by Elias Sundström and Marco Laudato
Bioengineering 2023, 10(10), 1216; https://doi.org/10.3390/bioengineering10101216 - 18 Oct 2023
Cited by 7 | Viewed by 3080
Abstract
Subjects with bicuspid aortic valves (BAV) are at risk of developing valve dysfunction and need regular clinical imaging surveillance. Management of BAV involves manual and time-consuming segmentation of the aorta for assessing left ventricular function, jet velocity, gradient, shear stress, and valve area [...] Read more.
Subjects with bicuspid aortic valves (BAV) are at risk of developing valve dysfunction and need regular clinical imaging surveillance. Management of BAV involves manual and time-consuming segmentation of the aorta for assessing left ventricular function, jet velocity, gradient, shear stress, and valve area with aortic valve stenosis. This paper aims to employ machine learning-based (ML) segmentation as a potential for improved BAV assessment and reducing manual bias. The focus is on quantifying the relationship between valve morphology and vortical structures, and analyzing how valve morphology influences the aorta’s susceptibility to shear stress that may lead to valve incompetence. The ML-based segmentation that is employed is trained on whole-body Computed Tomography (CT). Magnetic Resonance Imaging (MRI) is acquired from six subjects, three with tricuspid aortic valves (TAV) and three functionally BAV, with right–left leaflet fusion. These are used for segmentation of the cardiovascular system and delineation of four-dimensional phase-contrast magnetic resonance imaging (4D-PCMRI) for quantification of vortical structures and wall shear stress. The ML-based segmentation model exhibits a high Dice score (0.86) for the heart organ, indicating a robust segmentation. However, the Dice score for the thoracic aorta is comparatively poor (0.72). It is found that wall shear stress is predominantly symmetric in TAVs. BAVs exhibit highly asymmetric wall shear stress, with the region opposite the fused coronary leaflets experiencing elevated tangential wall shear stress. This is due to the higher tangential velocity explained by helical flow, proximally of the sinutubal junction of the ascending aorta. ML-based segmentation not only reduces the runtime of assessing the hemodynamic effectiveness, but also identifies the significance of the tangential wall shear stress in addition to the axial wall shear stress that may lead to the progression of valve incompetence in BAVs, which could guide potential adjustments in surgical interventions. Full article
Show Figures

Graphical abstract

11 pages, 5101 KiB  
Article
Four-Dimensional Flow MRI for the Evaluation of Aortic Endovascular Graft: A Pilot Study
by Paolo Righini, Francesco Secchi, Daniela Mazzaccaro, Daniel Giese, Marina Galligani, Dor Avishay, Davide Capra, Caterina Beatrice Monti and Giovanni Nano
Diagnostics 2023, 13(12), 2113; https://doi.org/10.3390/diagnostics13122113 - 19 Jun 2023
Cited by 2 | Viewed by 2623
Abstract
We aimed to explore the feasibility of 4D flow magnetic resonance imaging (MRI) for patients undergoing thoracic aorta endovascular repair (TEVAR). We retrospectively evaluated ten patients (two female), with a mean (±standard deviation) age of 61 ± 20 years, undergoing MRI for a [...] Read more.
We aimed to explore the feasibility of 4D flow magnetic resonance imaging (MRI) for patients undergoing thoracic aorta endovascular repair (TEVAR). We retrospectively evaluated ten patients (two female), with a mean (±standard deviation) age of 61 ± 20 years, undergoing MRI for a follow-up after TEVAR. All 4D flow examinations were performed using a 1.5-T system (MAGNETOM Aera, Siemens Healthcare, Erlangen, Germany). In addition to the standard examination protocol, a 4D flow-sensitive 3D spatial-encoding, time-resolved, phase-contrast prototype sequence was acquired. Among our cases, flow evaluation was feasible in all patients, although we observed some artifacts in 3 out of 10 patients. Three individuals displayed a reduced signal within the vessel lumen where the endograft was placed, while others presented with turbulent or increased flow. An aortic endograft did not necessarily hinder the visualization of blood flow through 4D flow sequences, although the graft could generate flow artifacts in some cases. A 4D Flow MRI may represent the ideal tool to follow up on both healthy subjects deemed to be at an increased risk based on their anatomical characteristics or patients submitted to TEVAR for whom a surveillance protocol with computed tomography angiography would be cumbersome and unjustified. Full article
(This article belongs to the Collection Vascular Diseases Diagnostics)
Show Figures

Figure 1

14 pages, 4356 KiB  
Article
4D-Flow Cardiovascular Magnetic Resonance Sequence for Aortic Assessment: Multi-Vendor and Multi-Magnetic Field Reproducibility in Healthy Volunteers
by Bruna Punzo, Brigida Ranieri, Liberatore Tramontano, Ornella Affinito, Monica Franzese, Eduardo Bossone, Luca Saba, Carlo Cavaliere and Filippo Cademartiri
J. Clin. Med. 2023, 12(8), 2960; https://doi.org/10.3390/jcm12082960 - 19 Apr 2023
Cited by 5 | Viewed by 2651
Abstract
Objectives: Four-dimensional (4D) flow cardiac magnetic resonance (CMR) represents an emerging technique for non-invasive evaluation of the aortic flow. The aim of this study was to investigate a 4D-flow CMR sequence for the assessment of thoracic aorta comparing different vendors and different magnetic [...] Read more.
Objectives: Four-dimensional (4D) flow cardiac magnetic resonance (CMR) represents an emerging technique for non-invasive evaluation of the aortic flow. The aim of this study was to investigate a 4D-flow CMR sequence for the assessment of thoracic aorta comparing different vendors and different magnetic fields of MR scanner in fifteen healthy volunteers. Methods: CMR was performed on three different MRI scanners: one at 1.5 T and two at 3 T. Flow parameters and planar wall shear stress (WSS) were extracted from six transversal planes along the full thoracic aorta by three operators. Inter-vendor comparability as well as scan–rescan, intra- and interobserver reproducibility were examined. Results: A high heterogeneity was found in the comparisons for each operator and for each scanner in the six transversal planes analysis (Friedman rank-sum test; p-value ≤ 0.05). Among all, the most reproducible measures were extracted for the sinotubular junction plane and for the flow parameters. Conclusions: Our results suggest that standardized procedures have to be defined to make more comparable and reproducible 4D-flow parameters and mainly, clinical impactfulness. Further studies on sequences development are needed to validate 4D-flow MRI assessment across vendors and magnetic fields also compared to a missing gold standard. Full article
(This article belongs to the Special Issue Clinical Applications of Cardiovascular Magnetic Resonance Imaging)
Show Figures

Figure 1

12 pages, 643 KiB  
Article
The Importance of Mitral Valve Prolapse Doming Volume in the Assessment of Left Ventricular Stroke Volume with Cardiac MRI
by Rui Li, Hosamadin Assadi, Gareth Matthews, Zia Mehmood, Ciaran Grafton-Clarke, Bahman Kasmai, David Hewson, Richard Greenwood, Hilmar Spohr, Liang Zhong, Xiaodan Zhao, Chris Sawh, Rudolf Duehmke, Vassilios S. Vassiliou, Faye Nelthorpe, David Ashman, John Curtin, Gurung-Koney Yashoda, Rob J. Van der Geest, Samer Alabed, Andrew J. Swift, Marina Hughes and Pankaj Gargadd Show full author list remove Hide full author list
Med. Sci. 2023, 11(1), 13; https://doi.org/10.3390/medsci11010013 - 24 Jan 2023
Cited by 4 | Viewed by 3515
Abstract
There remains a debate whether the ventricular volume within prolapsing mitral valve (MV) leaflets should be included in the left ventricular (LV) end-systolic volume, and therefore factored in LV stroke volume (SV), in cardiac magnetic resonance (CMR) assessments. This study aims to compare [...] Read more.
There remains a debate whether the ventricular volume within prolapsing mitral valve (MV) leaflets should be included in the left ventricular (LV) end-systolic volume, and therefore factored in LV stroke volume (SV), in cardiac magnetic resonance (CMR) assessments. This study aims to compare LV volumes during end-systolic phases, with and without the inclusion of the volume of blood on the left atrial aspect of the atrioventricular groove but still within the MV prolapsing leaflets, against the reference LV SV by four-dimensional flow (4DF). A total of 15 patients with MV prolapse (MVP) were retrospectively enrolled in this study. We compared LV SV with (LV SVMVP) and without (LV SVstandard) MVP left ventricular doming volume, using 4D flow (LV SV4DF) as the reference value. Significant differences were observed when comparing LV SVstandard and LV SVMVP (p < 0.001), and between LV SVstandard and LV SV4DF (p = 0.02). The Intraclass Correlation Coefficient (ICC) test demonstrated good repeatability between LV SVMVP and LV SV4DF (ICC = 0.86, p < 0.001) but only moderate repeatability between LV SVstandard and LV SV4DF (ICC = 0.75, p < 0.01). Calculating LV SV by including the MVP left ventricular doming volume has a higher consistency with LV SV derived from the 4DF assessment. In conclusion, LV SV short-axis cine assessment incorporating MVP dooming volume can significantly improve the precision of LV SV assessment compared to the reference 4DF method. Hence, in cases with bi-leaflet MVP, we recommend factoring in MVP dooming into the left ventricular end-systolic volume to improve the accuracy and precision of quantifying mitral regurgitation. Full article
(This article belongs to the Section Cardiovascular Disease)
Show Figures

Figure 1

16 pages, 1337 KiB  
Review
Imaging and Hemodynamic Characteristics of Vulnerable Carotid Plaques and Artificial Intelligence Applications in Plaque Classification and Segmentation
by Na Han, Yurong Ma, Yan Li, Yu Zheng, Chuang Wu, Tiejun Gan, Min Li, Laiyang Ma and Jing Zhang
Brain Sci. 2023, 13(1), 143; https://doi.org/10.3390/brainsci13010143 - 13 Jan 2023
Cited by 13 | Viewed by 4242
Abstract
Stroke is a massive public health problem. The rupture of vulnerable carotid atherosclerotic plaques is the most common cause of acute ischemic stroke (AIS) across the world. Currently, vessel wall high-resolution magnetic resonance imaging (VW-HRMRI) is the most appropriate and cost-effective imaging technique [...] Read more.
Stroke is a massive public health problem. The rupture of vulnerable carotid atherosclerotic plaques is the most common cause of acute ischemic stroke (AIS) across the world. Currently, vessel wall high-resolution magnetic resonance imaging (VW-HRMRI) is the most appropriate and cost-effective imaging technique to characterize carotid plaque vulnerability and plays an important role in promoting early diagnosis and guiding aggressive clinical therapy to reduce the risk of plaque rupture and AIS. In recent years, great progress has been made in imaging research on vulnerable carotid plaques. This review summarizes developments in the imaging and hemodynamic characteristics of vulnerable carotid plaques on the basis of VW-HRMRI and four-dimensional (4D) flow MRI, and it discusses the relationship between these characteristics and ischemic stroke. In addition, the applications of artificial intelligence in plaque classification and segmentation are reviewed. Full article
(This article belongs to the Topic Diagnosis and Management of Acute Ischemic Stroke)
Show Figures

Figure 1

18 pages, 1829 KiB  
Review
Evaluation of Left Ventricular Function Using Four-Dimensional Flow Cardiovascular Magnetic Resonance: A Systematic Review
by Jiaxing Jason Qin, Ben Indja, Alireza Gholipour, Mustafa Gök and Stuart M. Grieve
J. Cardiovasc. Dev. Dis. 2022, 9(9), 304; https://doi.org/10.3390/jcdd9090304 - 12 Sep 2022
Cited by 7 | Viewed by 2120
Abstract
There is increasing recognition of the value of four-dimensional flow cardiovascular magnetic resonance (4D-flow MRI) as a potential means to detect and measure abnormal flow behaviour that occurs during early left ventricular (LV) dysfunction. We performed a systematic review of current literature on [...] Read more.
There is increasing recognition of the value of four-dimensional flow cardiovascular magnetic resonance (4D-flow MRI) as a potential means to detect and measure abnormal flow behaviour that occurs during early left ventricular (LV) dysfunction. We performed a systematic review of current literature on the role of 4D-flow MRI-derived flow parameters in quantification of LV function with a focus on potential clinical applicability. A comprehensive literature search was performed in March 2022 on available databases. A total of 1186 articles were identified, and 30 articles were included in the final analysis. All the included studies were ranked as “highly clinically applicable”. There was considerable variability in the reporting of methodologies and analyses. All the studies were small-scale feasibility or pilot studies investigating a diverse range of flow parameters. The most common primary topics of investigation were energy-related flow parameters, flow components and vortex analysis which demonstrated potentials for quantifying early diastolic dysfunction, whilst other parameters including haemodynamic forces, residence time distribution and turbulent kinetic energy remain in need of further evaluation. Systematic quantitative comparison of study findings was not possible due to this heterogeneity, therefore limiting the collective power of the studies in evaluating clinical applicability of the flow parameters. To achieve broader clinical application of 4D-flow MRI, larger scale investigations are required, together with standardisation of methodologies and analytical approach. Full article
Show Figures

Figure 1

10 pages, 1673 KiB  
Article
Intracranial Flow Velocity Quantification Using Non-Contrast Four-Dimensional Flow MRI: A Prospective Comparative Study with Transcranial Doppler Ultrasound
by Sam-Yeol Ha, Yeonah Kang, Ho-Joon Lee, Moonjung Hwang, Jiyeon Baik and Seongho Park
Diagnostics 2022, 12(1), 23; https://doi.org/10.3390/diagnostics12010023 - 23 Dec 2021
Cited by 3 | Viewed by 3365
Abstract
Four-dimensional (4D) flow magnetic resonance imaging (MRI) allows three-dimensional velocity encoding to measure blood flow in a single scan, regardless of the intracranial artery direction. We compared blood flow velocity quantification by non-contrast 4D flow MRI and by transcranial Doppler ultrasound (TCD), the [...] Read more.
Four-dimensional (4D) flow magnetic resonance imaging (MRI) allows three-dimensional velocity encoding to measure blood flow in a single scan, regardless of the intracranial artery direction. We compared blood flow velocity quantification by non-contrast 4D flow MRI and by transcranial Doppler ultrasound (TCD), the most widely used modality for measuring velocity. Twenty-two patients underwent both TCD and non-contrast 4D flow MRI. The mean time interval between TCD and non-contrast 4D flow MRI was 0.7 days. Subsegmental velocities were measured bilaterally in the middle cerebral and basilar arteries using TCD and non-contrast 4D flow MRI. Intracranial velocity measurements using TCD and non-contrast 4D flow MRI demonstrated a strong correlation in the bilateral M1, especially at the proximal segment (right r = 0.74, left r = 0.78; all p < 0.001). Mean velocities acquired with 4D flow MRI were approximately 8 to 10% lower than those acquired with TCD according to the location of M1. Intracranial arterial flow measurements estimated using non-contrast 4D flow MRI and TCD showed strong correlation. 4D flow MRI enables simultaneous assessment of vascular morphology and quantitative hemodynamic measurement, providing three-dimensional blood flow visualization. 4D flow MRI is a clinically useful sequence with a promising role in cerebrovascular disease. Full article
(This article belongs to the Special Issue Advanced Cerebrovascular and Craniocervical Imaging)
Show Figures

Figure 1

15 pages, 2351 KiB  
Article
Before and after Endovascular Aortic Repair in the Same Patients with Aortic Dissection: A Cohort Study of Four-Dimensional Phase-Contrast Magnetic Resonance Imaging
by Chien-Wei Chen, Yueh-Fu Fang, Yuan-Hsi Tseng, Min Yi Wong, Yu-Hui Lin, Yin-Chen Hsu, Bor-Shyh Lin and Yao-Kuang Huang
Diagnostics 2021, 11(10), 1912; https://doi.org/10.3390/diagnostics11101912 - 15 Oct 2021
Cited by 1 | Viewed by 2750
Abstract
(1) Background: We used four-dimensional phase-contrast magnetic resonance imaging (4D PC-MRI) to evaluate the impact of an endovascular aortic repair (TEVAR) on aortic dissection. (2) Methods: A total of 10 patients received 4D PC-MRI on a 1.5-T MR both before and after TEVAR. [...] Read more.
(1) Background: We used four-dimensional phase-contrast magnetic resonance imaging (4D PC-MRI) to evaluate the impact of an endovascular aortic repair (TEVAR) on aortic dissection. (2) Methods: A total of 10 patients received 4D PC-MRI on a 1.5-T MR both before and after TEVAR. (3) Results: The aortas were repaired with either a GORE TAG Stent (Gore Medical; n = 7) or Zenith Dissection Endovascular Stent (Cook Medical; n = 3). TEVAR increased the forward flow volume of the true lumen (TL) (at the abdominal aorta, p = 0.047). TEVAR also reduced the regurgitant fraction in the TL at the descending aorta but increased it in the false lumen (FL). After TEVAR, the stroke distance increased in the TL (at descending and abdominal aorta, p = 0.018 and 0.015), indicating more effective blood transport per heartbeat. Post-stenting quantitative flow revealed that the reductions in stroke volume, backward flow volume, and absolute stroke volume were greater when covered stents were used than when bare stents were used in the FL of the descending aorta. Bare stents had a higher backward flow volume than covered stents did. (4) Conclusions: TEVAR increased the stroke volume in the TL and increased the regurgitant fraction in the FL in patients with aortic dissection. Full article
(This article belongs to the Special Issue Advanced Techniques in Body Magnetic Resonance Imaging 2.0)
Show Figures

Figure 1

13 pages, 4841 KiB  
Article
Improving Blood Flow Visualization of Recirculation Regions at Carotid Bulb in 4D Flow MRI Using Semi-Automatic Segmentation with ITK-SNAP
by Minh Tri Ngo, Ui Yun Lee, Hojin Ha, Jinmu Jung, Dong Hwan Lee and Hyo Sung Kwak
Diagnostics 2021, 11(10), 1890; https://doi.org/10.3390/diagnostics11101890 - 13 Oct 2021
Cited by 7 | Viewed by 3200
Abstract
Assessment of carotid bulb hemodynamics using four-dimensional (4D) flow magnetic resonance imaging (MRI) requires accurate segmentation of recirculation regions that is frequently hampered by limited resolution. This study aims to improve the accuracy of 4D flow MRI carotid bulb segmentation and subsequent recirculation [...] Read more.
Assessment of carotid bulb hemodynamics using four-dimensional (4D) flow magnetic resonance imaging (MRI) requires accurate segmentation of recirculation regions that is frequently hampered by limited resolution. This study aims to improve the accuracy of 4D flow MRI carotid bulb segmentation and subsequent recirculation regions analysis. Time-of-flight (TOF) MRI and 4D flow MRI were performed on bilateral carotid artery bifurcations in seven healthy volunteers. TOF-MRI data was segmented into 3D geometry for computational fluid dynamics (CFD) simulations. ITK-SNAP segmentation software was included in the workflow for the semi-automatic generation of 4D flow MRI angiographic data. This study compared the velocities calculated at the carotid bifurcations and the 3D blood flow visualization at the carotid bulbs obtained by 4D flow MRI and CFD. By applying ITK-SNAP segmentation software, an obvious improvement in the 4D flow MRI visualization of the recirculation regions was observed. The 4D flow MRI images of the recirculation flow characteristics of the carotid artery bulbs coincided with the CFD. A reasonable agreement was found in terms of velocity calculated at the carotid bifurcation between CFD and 4D flow MRI. However, the dispersion of velocity data points relative to the local errors of measurement in 4D flow MRI remains. Our proposed strategy showed the feasibility of improving recirculation regions segmentation and the potential for reliable blood flow visualization in 4D flow MRI. However, quantitative analysis of recirculation regions in 4D flow MRI with ITK-SNAP should be enhanced for use in clinical situations. Full article
(This article belongs to the Section Medical Imaging and Theranostics)
Show Figures

Figure 1

13 pages, 4779 KiB  
Article
Comparison of Four-Dimensional Flow Magnetic Resonance Imaging and Particle Image Velocimetry to Quantify Velocity and Turbulence Parameters
by Doohyeon Kim, Jihun Kang, Ehsan Adeeb, Gyu-Han Lee, Dong Hyun Yang and Hojin Ha
Fluids 2021, 6(8), 277; https://doi.org/10.3390/fluids6080277 - 6 Aug 2021
Cited by 7 | Viewed by 3138
Abstract
Although recent advances of four-dimensional (4D) flow magnetic resonance imaging (MRI) has introduced a new way to measure Reynolds stress tensor (RST) in turbulent flows, its measurement accuracy and possible bias have remained to be revealed. The purpose of this study was to [...] Read more.
Although recent advances of four-dimensional (4D) flow magnetic resonance imaging (MRI) has introduced a new way to measure Reynolds stress tensor (RST) in turbulent flows, its measurement accuracy and possible bias have remained to be revealed. The purpose of this study was to compare the turbulent flow measurement of 4D flow MRI and particle image velocimetry (PIV) in terms of velocity and turbulence quantification. Two difference flow rates of 10 and 20 L/min through a 50% stenosis were measured with both PIV and 4D flow MRI. Not only velocity through the stenosis but also the turbulence parameters such as turbulence kinetic energy and turbulence production were quantitatively compared. Results shows that 4D flow MRI velocity measurement well agreed with the that of PIV, showing the linear regression slopes of two methods are 0.94 and 0.89, respectively. Although turbulence mapping of 4D flow MRI was qualitatively agreed with that of PIV, the quantitative comparison shows that the 4D flow MRI overestimates RST showing the linear regression slopes of 1.44 and 1.66, respectively. In this study, we demonstrate that the 4D flow MRI visualize and quantify not only flow velocity and also turbulence tensor. However, further optimization of 4D flow MRI for better accuracy might be remained. Full article
Show Figures

Figure 1

Back to TopTop