Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

remove_circle_outline
remove_circle_outline

Search Results (239)

Search Parameters:
Keywords = fire-resistant systems

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
22 pages, 5839 KiB  
Article
Fire Safety of Curtain Walling: Evidence-Based Critical Review and New Test Configuration Proposal for EN 1364-4
by Arritokieta Eizaguirre-Iribar, Raya Stoyanova Trifonova, Peter Ens and Xabier Olano-Azkune
Fire 2025, 8(8), 311; https://doi.org/10.3390/fire8080311 - 6 Aug 2025
Abstract
This article focuses on the fire safety risks associated with conventional glass–aluminum façades—with a particular focus on stick and unitized curtain walling systems—providing an overview of possible fire spread mechanisms, considering the role of the curtain wall in maintaining compartmentation at the spandrel [...] Read more.
This article focuses on the fire safety risks associated with conventional glass–aluminum façades—with a particular focus on stick and unitized curtain walling systems—providing an overview of possible fire spread mechanisms, considering the role of the curtain wall in maintaining compartmentation at the spandrel zone. First, it analyzes some of the relevant requirements of different European building regulations. Then, it provides a test evidence-based critical analysis of the gaps and loopholes in the relevant fire resistance standard for partial curtain wall configurations (EN 1364-4), where the evaluation of the propagation within the façade system is not necessarily considered in the fire-resistant spandrel zone. Finally, it presents a proposal for addressing these gaps in the form of a theoretical concept for a new test configuration and additional assessment criteria. This is followed by an initial experimental analysis of the concept. The standard testing campaign showed that temperature rise in mullions can exceed 180 °C after 30 min if limiting measures are not considered in the façade design. However, this can be only detected if framing is in the non-exposed area of the sample, being part of the evaluation surface. Meanwhile, differences are detected between the results from standard and new assessment criteria in the new configuration proposed, including a more rapid temperature rise for framing elements (207 K in a second level mullion at minute 90) than for the common non-exposed assessment surface of the sample (172 K at the same time) in cases where cavities are not protected. Accordingly, the proposed configuration successfully detected vertical temperature transfer within mullions, which can remain undetected in standard EN 1364-4 tests, highlighting the potential for fire spread even in EI120-rated assemblies. Full article
Show Figures

Figure 1

19 pages, 2633 KiB  
Article
Influence of Mullite and Halloysite Reinforcement on the Ablation Properties of an Epoxy Composite
by Robert Szczepaniak, Michał Piątkiewicz, Dominik Gryc, Paweł Przybyłek, Grzegorz Woroniak and Joanna Piotrowska-Woroniak
Materials 2025, 18(15), 3530; https://doi.org/10.3390/ma18153530 - 28 Jul 2025
Viewed by 280
Abstract
This paper explores the impact of applying a powder additive in the form of halloysite and mullite on the thermal protection properties of a composite. The authors used CES R70 epoxy resin with CES H72 hardener, modified by varying the amount of powder [...] Read more.
This paper explores the impact of applying a powder additive in the form of halloysite and mullite on the thermal protection properties of a composite. The authors used CES R70 epoxy resin with CES H72 hardener, modified by varying the amount of powder additive. The composite samples were exposed to a mixture of combustible gases at a temperature of approximately 1000 °C. The primary parameters analyzed during this study were the temperature on the rear surface of the sample and the ablative mass loss of the tested material. The temperature increase on the rear surface of the sample, which was exposed to the hot stream of flammable gases, was measured for 120 s. Another key parameter considered in the data analysis was the ablative mass loss. The charred layer of the sample played a crucial role in this process, as it helped block oxygen diffusion from the boundary layer of the original material. This charred layer absorbed thermal energy until it reached a temperature at which it either oxidized or was mechanically removed due to the erosive effects of the heating factor. The incorporation of mullite reduced the rear surface temperature from 58.9 °C to 49.2 °C, and for halloysite, it was reduced the rear surface temperature to 49.8 °C. The ablative weight loss dropped from 57% to 18.9% for mullite and to 39.9% for halloysite. The speed of mass ablation was reduced from 77.9 mg/s to 25.2 mg/s (mullite) and 52.4 mg/s (halloysite), while the layer thickness loss decreased from 7.4 mm to 2.8 mm (mullite) and 4.4 mm (halloysite). This research is innovative in its use of halloysite and mullite as functional additives to enhance the ablative resistance of polymer composites under extreme thermal conditions. This novel approach not only contributes to a deeper understanding of composite behavior at high temperatures but also opens up new avenues for the development of advanced thermal protection systems. Potential applications of these materials include aerospace structures, fire-resistant components, and protective coatings in environments exposed to intense heat and flame. Full article
(This article belongs to the Section Advanced Composites)
Show Figures

Figure 1

31 pages, 11979 KiB  
Article
Fire-Induced Collapse Analysis of Warehouse Structures Using FDS and Thermomechanical Modeling
by Fatih Yesevi Okur
Buildings 2025, 15(15), 2635; https://doi.org/10.3390/buildings15152635 - 25 Jul 2025
Viewed by 330
Abstract
This study investigates the fire dynamics and structural response of steel-framed warehouse racking systems under various fire scenarios, emphasizing the critical importance of fire safety measures in mitigating structural damage. Through advanced computational simulations (Fire Dynamics Simulator) and thermomechanical analysis, this research reveals [...] Read more.
This study investigates the fire dynamics and structural response of steel-framed warehouse racking systems under various fire scenarios, emphasizing the critical importance of fire safety measures in mitigating structural damage. Through advanced computational simulations (Fire Dynamics Simulator) and thermomechanical analysis, this research reveals that fire intensity and progression are highly influenced by the ignition point and the stored material types, with maximum recorded temperatures reaching 720 °C and 970 °C in different scenarios. The results highlight the localization of significant strain and drift ratios in structural elements near the ignition zone, underscoring their vulnerability. This study demonstrates the rapid loss of load-bearing capacity in steel elements at elevated temperatures, leading to severe deformations and increased collapse risks. Key findings emphasize the necessity of strategically positioned sprinkler systems and the integration of passive fire protection measures, such as fire-resistant coatings, to enhance structural resilience. Performance-based fire design approaches, aligning with FEMA-356 criteria, offer realistic frameworks for improving the fire safety of warehouse structures. Full article
(This article belongs to the Section Building Structures)
Show Figures

Figure 1

17 pages, 1956 KiB  
Article
Effect of Bio-Based Flame Retardants in Sustainable Epoxy Systems for the Development of Composite Materials
by Patricia Ares-Elejoste, Rubén Seoane-Rivero, Inaki Gandarias, Jesus Ballestero and Ane Libe Alonso-Amondarain
Polymers 2025, 17(15), 2001; https://doi.org/10.3390/polym17152001 - 22 Jul 2025
Viewed by 404
Abstract
The composite materials industry is increasingly seeking sustainable alternatives to mitigate the environmental impact of end-of-life materials. As a result, many sectors are transitioning toward bio-based or partially bio-based matrices (e.g., epoxy resins) to preserve material properties while improving sustainability. The transportation sector, [...] Read more.
The composite materials industry is increasingly seeking sustainable alternatives to mitigate the environmental impact of end-of-life materials. As a result, many sectors are transitioning toward bio-based or partially bio-based matrices (e.g., epoxy resins) to preserve material properties while improving sustainability. The transportation sector, in particular, demands materials that meet stringent mechanical and fire resistance standards. In this study, various epoxy systems with bio-based and/or recyclable content were investigated, along with renewable additives designed to enhance fire resistance through their functional groups and chemical structure. The research focused on developing formulations compatible with Sheet Moulding Compound (SMC) technology, which is widely used in transportation applications. Through extensive testing, materials with high bio-based content were successfully developed, exhibiting competitive mechanical properties and compliance with key fire safety requirements of the railway sector, as per the EN 45545-2 standard. Full article
(This article belongs to the Section Polymer Composites and Nanocomposites)
Show Figures

Graphical abstract

17 pages, 2256 KiB  
Article
Performance Analysis of Different Borehole Heat Exchanger Configurations: A Case Study in NW Italy
by Jessica Maria Chicco, Nicolò Giordano, Cesare Comina and Giuseppe Mandrone
Smart Cities 2025, 8(4), 121; https://doi.org/10.3390/smartcities8040121 - 21 Jul 2025
Viewed by 330
Abstract
The central role of heating and cooling in energy transition has been recognised in recent years, especially with geopolitical developments since February 2022 which demand an acceleration in deploying local energy sources to increase the resilience of the energy sector. Geothermal energy is [...] Read more.
The central role of heating and cooling in energy transition has been recognised in recent years, especially with geopolitical developments since February 2022 which demand an acceleration in deploying local energy sources to increase the resilience of the energy sector. Geothermal energy is a promising and vital option to optimize heating and cooling systems, promoting sustainability of urban environments. To this end, a proper design is of paramount importance to guarantee the energy performance of the whole system. This work deals with the optimization of the technical and geometrical characteristics of borehole heat exchangers (BHEs) as part of a shallow geothermal plant that is assumed to be integrated in an already operating gas-fired DH grid. Thermal performances of three different configurations were analysed according to the geological information that revealed an aquifer at −36 m overlying a poorly permeable marly succession. Numerical simulations validated the geological, hydrogeological, and thermo-physical models by back-analysing the experimental results of a thermal response test (TRT) on a pilot 150 m deep BHE. Five-year simulations were then performed to compare 150 m and 36 m polyethylene 2U, and 36 m steel coaxial BHEs. The coaxial configuration shows the best performance both in terms of specific power (74.51 W/m) and borehole thermal resistance (0.02 mK/W). Outcomes of the study confirm that coupling the best geological and technical parameters ensure the best energy performance and economic sustainability. Full article
(This article belongs to the Special Issue Energy Strategies of Smart Cities)
Show Figures

Figure 1

18 pages, 6310 KiB  
Article
Physico-Mechanical Properties and Decay Susceptibility of Clay Bricks After the Addition of Volcanic Ash from La Palma (Canary Islands, Spain)
by María López Gómez and Giuseppe Cultrone
Sustainability 2025, 17(14), 6545; https://doi.org/10.3390/su17146545 - 17 Jul 2025
Viewed by 262
Abstract
During a volcanic eruption, a large volume of pyroclastic material can be deposited on the roads and roofs of the urban areas near volcanoes. The use of volcanic ash as an additive for the manufacture of bricks provides a solution to the disposal [...] Read more.
During a volcanic eruption, a large volume of pyroclastic material can be deposited on the roads and roofs of the urban areas near volcanoes. The use of volcanic ash as an additive for the manufacture of bricks provides a solution to the disposal of part of this natural residue and reduces the depletion of a non-renewable natural resource, clayey soil, which brings some environmental and economic advantages. The pore system, compactness, uniaxial compression strength, thermal conductivity, color and durability of bricks without and with the addition of volcanic ash were evaluated through hydric tests, mercury intrusion porosimetry, ultrasound, uniaxial compression tests, IR thermography, spectrophotometry and salt crystallization tests. The purpose of this research is to determine the feasibility of adding 10, 20 and 30% by weight of volcanic ash from La Palma (Canary Islands, Spain) in two grain sizes to produce bricks fired at 800, 950 and 1100 °C. The novelty of this study is to use two sizes of volcanic ash and fire the samples at 1100 °C, which is close to the liquidus temperature of basaltic magmas and allows a high degree of interaction between the volcanic ash and the brick matrix. The addition of fine volcanic ash was found to decrease the porosity of the bricks, although the use of high percentages of coarse volcanic ash resulted in bricks with almost the same porosity as the control samples. The volcanic ash acted as a filler, reducing the number of small pores in the bricks. The presence of vesicles in the volcanic ash reduced the compressive strength and the compactness of the bricks with additives. This reduction was more evident in bricks manufactured with 30% of coarse volcanic ash and fired at 800 and 950 °C, although they still reached the minimum resistance required for their use in construction. No significant differences in thermal conductivity were noticed between the bricks with and without volcanic ash additives, which is crucial in terms of energy savings and the construction of sustainable buildings. At 1100 °C the volcanic ash changed in color from black to red. As a result, the additive blended in better with the matrix of bricks fired at 1100 °C than in those fired at 800 and 950 °C. The bricks with and without volcanic ash and fired at 1100 °C remained intact after the salt crystallization tests. Less salt crystallized in the bricks with volcanic ash and fired at 800 and 950 °C than in the samples without additives, although their low compressive strength made them susceptible to decay. Full article
(This article belongs to the Special Issue Innovating the Circular Future: Pathways to Sustainable Growth)
Show Figures

Figure 1

17 pages, 432 KiB  
Article
Internal Validation of a Machine Learning-Based CDSS for Antimicrobial Stewardship
by Ari Frenkel, Alicia Rendon, Carlos Chavez-Lencinas, Juan Carlos Gomez De la Torre, Jen MacDermott, Collen Gross, Stephanie Allman, Sheri Lundblad, Ivanna Zavala, Dave Gross, Jessica Siegel, Soojung Choi and Miguel Hueda-Zavaleta
Life 2025, 15(7), 1123; https://doi.org/10.3390/life15071123 - 17 Jul 2025
Viewed by 405
Abstract
Background: Antimicrobial stewardship programs (ASPs) are essential in combating antimicrobial resistance (AMR); however, limited resources hinder their implementation. Arkstone, a biotechnology company, developed a machine learning (ML)-driven clinical decision support system (CDSS) to guide antimicrobial prescribing. While AI (artificial intelligence) applications are increasingly [...] Read more.
Background: Antimicrobial stewardship programs (ASPs) are essential in combating antimicrobial resistance (AMR); however, limited resources hinder their implementation. Arkstone, a biotechnology company, developed a machine learning (ML)-driven clinical decision support system (CDSS) to guide antimicrobial prescribing. While AI (artificial intelligence) applications are increasingly used, each model must be carefully validated. Methods: Three components of the ML system were assessed: (1) A prospective observational study tested its ability to distinguish trained from novel data using various validation techniques and BioFire molecular panel inputs. (2) An anonymous retrospective analysis of internal infectious disease lab results evaluated the recognition of novel versus trained complex datasets. (3) A prospective observational validation study reviewed clinical recommendations against standard guidelines by independent clinicians. Results: The system achieved 100% accuracy (F1 = 1) in identifying 111 unique novel data points across 1110 tests over nine training sessions. It correctly identified all 519 fully trained and 644 novel complex datasets. Among 644 clinician-trained reports, there were no major discrepancies in recommendations, with only 100 showing minor differences. Conclusions: This novel ML system demonstrated high accuracy in distinguishing trained from novel data and produced recommendations consistent with clinical guidelines. These results support its value in strengthening CDSS and ASP efforts. Full article
(This article belongs to the Section Medical Research)
Show Figures

Figure 1

29 pages, 13314 KiB  
Article
Development of Unfired Clay Bricks with Alumina Waste from Liquid Nitrogen Production: A Sustainable Alternative for Construction Materials
by Noppadol Sangiamsak, Nopanom Kaewhanam, Meesakthana Puapitthayathorn, Seksan Numsong, Kowit Suwannahong, Sukanya Hongthong, Torpong Kreetachat, Sompop Sanongraj and Surachai Wongcharee
Sustainability 2025, 17(14), 6424; https://doi.org/10.3390/su17146424 - 14 Jul 2025
Viewed by 417
Abstract
A major breakthrough in environmentally friendly building materials is the development of sustainable unfired clay bricks including alumina waste produced during liquid nitrogen generation. Though used extensively, conventional fired clay bricks require energy-intensive manufacturing techniques that produce significant amounts of CO2 and [...] Read more.
A major breakthrough in environmentally friendly building materials is the development of sustainable unfired clay bricks including alumina waste produced during liquid nitrogen generation. Though used extensively, conventional fired clay bricks require energy-intensive manufacturing techniques that produce significant amounts of CO2 and aggravate environmental damage. By removing the need for high-temperature firing and allowing for the valorization of industrial byproducts including alumina waste and lateritic soil, unfired clay bricks offer a reasonable low-carbon alternative. High silica and alumina contents define the alumina waste, which shows pozzolanic reactivity, thus improving the physicomechanical performance of the bricks. With alumina waste substituting 0–8.57% of the cement content, seven different formulations showed improvements in compressive strength, reduced water absorption, and optimal thermal conductivity. Especially, the mechanical performance was much enhanced with alumina waste inclusion up to 30%, without sacrificing thermal insulation capacity or moisture resistance. Further supporting the environmental and financial sustainability of the suggested brick compositions is the economic viability of using industrial waste and regionally derived soils. A comparative analysis of the conventional fired bricks shows that the unfired substitutes have a much lower environmental impact and show better mechanical properties, including greater compressive strength and modulus of rupture. These results support the more general goals of circular economy systems and low-carbon urban development by highlighting the feasibility of including alumina waste and lateritic soil into sustainable building materials. Using such waste-derived inputs in building fits world initiatives to lower resource consumption, lower greenhouse gas emissions, and build strong infrastructure systems. Full article
(This article belongs to the Special Issue Solid Waste Management and Sustainable Environmental Remediation)
Show Figures

Figure 1

26 pages, 2217 KiB  
Review
A Scientific Review of Recycling Practices and Challenges for Autoclaved Aerated Concrete in Sustainable Construction
by Shuxi (Hiro) Wang, Guomin Zhang, Chamila Gunasekara, David Law, Yongtao Tan and Weihan Sun
Buildings 2025, 15(14), 2453; https://doi.org/10.3390/buildings15142453 - 12 Jul 2025
Viewed by 542
Abstract
Autoclaved Aerated Concrete (AAC) is a lightweight, thermally insulating, and fire-resistant building material that has become prominent in sustainable construction due to its reduced production energy demands and minimal environmental impact. As an increasing number of AAC-based structures reach end-of-life, the effective recycling [...] Read more.
Autoclaved Aerated Concrete (AAC) is a lightweight, thermally insulating, and fire-resistant building material that has become prominent in sustainable construction due to its reduced production energy demands and minimal environmental impact. As an increasing number of AAC-based structures reach end-of-life, the effective recycling and reuse of AAC waste present both challenges and opportunities within the context of sustainable building practices and circular economy frameworks. This study presents a scientometric review of AAC recycling research published between 2014 and 2024, using the Web of Science database and bibliometric tools such as CiteSpace. Key trends, techniques, and knowledge gaps in AAC recycling are identified, highlighting issues such as high energy consumption, limited practical implementation, and the absence of standardized recovery protocols. The study also outlines emerging research pathways, including detailed material characterization, development of recycling standards, innovative reuse techniques, hybrid material systems, and the integration of recycled AAC in new construction. These insights provide a foundation for advancing sustainable building material strategies and inform policy and practice in construction waste management. Full article
(This article belongs to the Topic Sustainable Building Development and Promotion)
Show Figures

Figure 1

30 pages, 10507 KiB  
Article
Thermal Properties of Geopolymer Concretes with Lightweight Aggregates
by Agnieszka Przybek, Paulina Romańska, Kinga Korniejenko, Krzysztof Krajniak, Maria Hebdowska-Krupa and Michał Łach
Materials 2025, 18(13), 3150; https://doi.org/10.3390/ma18133150 - 3 Jul 2025
Cited by 1 | Viewed by 541
Abstract
Despite the availability of various materials for chimney applications, ongoing research seeks alternatives with improved thermal and chemical resistance. Geopolymers are a promising solution, exhibiting exceptional resistance to high temperatures, fire, and aggressive chemicals. This study investigates fly ash-based lightweight geopolymer concretes that [...] Read more.
Despite the availability of various materials for chimney applications, ongoing research seeks alternatives with improved thermal and chemical resistance. Geopolymers are a promising solution, exhibiting exceptional resistance to high temperatures, fire, and aggressive chemicals. This study investigates fly ash-based lightweight geopolymer concretes that incorporate expanded clay aggregate (E.C.A.), perlite (P), and foamed geopolymer aggregate (F.G.A.). The composites were designed to ensure a density below 1200 kg/m3, reducing overall weight while maintaining necessary performance. Aggregate content ranged from 60 to 75 wt.%. Physical (density, thickness, water absorption), mechanical (flexural and compressive strength), and thermal (conductivity, resistance) properties were evaluated. F.G.A. 60 achieved a 76.8% reduction in thermal conductivity (0.1708 vs. 0.7366 W/(m·K)) and a 140.4% increase in thermal resistance (0.1642 vs. 0.0683). The F.G.A./E.C.A./P 60 mixture showed the highest compressive strength (18.069 MPa), reaching 52.7% of the reference concrete’s strength, with a 32.3% lower density (1173.3 vs. 1735.0 kg/m3). Water absorption ranged from 4.9% (REF.) to 7.3% (F.G.A. 60). All samples, except F.G.A. 70 and F.G.A. 75, endured heating up to 800 °C. The F.G.A./E.C.A./P 60 composite demonstrated well-balanced performance: low thermal conductivity (0.2052 W/(m·K)), thermal resistance up to 1000 °C, flexural strength of 4.386 MPa, and compressive strength of 18.069 MPa. The results confirm that well-designed geopolymer lightweight concretes are suitable for chimney and flue pipe linings operating between 500 and 1000 °C and exposed to acidic condensates and aggressive chemicals. This study marks the initial phase of a broader project on geopolymer-based prefabricated chimney systems. Full article
(This article belongs to the Special Issue Advances in Function Geopolymer Materials—Second Edition)
Show Figures

Figure 1

50 pages, 8944 KiB  
Review
Fire-Resistant Coatings: Advances in Flame-Retardant Technologies, Sustainable Approaches, and Industrial Implementation
by Rutu Patel, Mayankkumar L. Chaudhary, Yashkumar N. Patel, Kinal Chaudhari and Ram K. Gupta
Polymers 2025, 17(13), 1814; https://doi.org/10.3390/polym17131814 - 29 Jun 2025
Viewed by 1534
Abstract
Fire-resistant coatings have emerged as crucial materials for reducing fire hazards in various industries, including construction, textiles, electronics, and aerospace. This review provides a comprehensive account of recent advances in fire-resistant coatings, emphasizing environmentally friendly and high-performance systems. Beginning with a classification of [...] Read more.
Fire-resistant coatings have emerged as crucial materials for reducing fire hazards in various industries, including construction, textiles, electronics, and aerospace. This review provides a comprehensive account of recent advances in fire-resistant coatings, emphasizing environmentally friendly and high-performance systems. Beginning with a classification of traditional halogenated and non-halogenated flame retardants (FRs), this article progresses to cover nitrogen-, phosphorus-, and hybrid-based systems. The synthesis methods, structure–property relationships, and fire suppression mechanisms are critically discussed. A particular focus is placed on bio-based and waterborne formulations that align with green chemistry principles, such as tannic acid (TA), phytic acid (PA), lignin, and deep eutectic solvents (DESs). Furthermore, the integration of nanomaterials and smart functionalities into fire-resistant coatings has demonstrated promising improvements in thermal stability, char formation, and smoke suppression. Applications in real-world contexts, ranging from wood and textiles to electronics and automotive interiors, highlight the commercial relevance of these developments. This review also addresses current challenges such as long-term durability, environmental impacts, and the standardization of performance testing. Ultimately, this article offers a roadmap for developing safer, sustainable, and multifunctional fire-resistant coatings for future materials engineering. Full article
(This article belongs to the Special Issue Flame-Retardant Polymer Composites II)
Show Figures

Figure 1

15 pages, 2040 KiB  
Article
Research on the Flame-Retardant Performance of Antioxidant Gel Foam in Preventing Spontaneous Coal Combustion
by Hu Wen, Ziqi Wang and Maoxia Liu
Fire 2025, 8(7), 247; https://doi.org/10.3390/fire8070247 - 26 Jun 2025
Viewed by 328
Abstract
Antioxidant gel foams are promising materials for coal mine fire prevention due to their unique physicochemical properties. To address the limitations of conventional suppression methods under high-temperature conditions, this study investigates a newly developed antioxidant gel foam and its mechanism in inhibiting coal [...] Read more.
Antioxidant gel foams are promising materials for coal mine fire prevention due to their unique physicochemical properties. To address the limitations of conventional suppression methods under high-temperature conditions, this study investigates a newly developed antioxidant gel foam and its mechanism in inhibiting coal spontaneous combustion. A novel antioxidant gel foam was formulated by incorporating TBHQ and modified montmorillonite into a sodium alginate-based gel system. This formulation enhances the thermal stability, water retention, and free radical scavenging capacity of the gel. This study uniquely combines multi-scale experimental methods to evaluate the performance of this material in coal fire suppression. Multi-scale experiments, including FTIR, leakage air testing, programmed temperature rise, and small-scale fire extinction, were conducted to evaluate its performance. Experimental results indicate that the antioxidant gel foam exhibits excellent thermal stability in the temperature range of 200–500 °C. Its relatively high decomposition temperature enables it to effectively resist structural damage in high-temperature environments. During thermal decomposition, the gel releases only a small amount of gas, while maintaining the integrity of its internal micro-porous structure. This characteristic significantly delays the kinetics of coal oxidation reactions. Further research revealed that the spontaneous combustion ignition temperature of coal samples treated with the gel was significantly higher, and the oxygen consumption rate during spontaneous combustion was significantly reduced, indicating that the gel not only effectively suppressed the acceleration of the combustion reaction but also significantly reduced the release of harmful gases such as HCl. Scanning electron microscope analysis confirmed that the gel maintained a good physical structure under high temperatures, forming an effective oxygen barrier, which further enhanced the suppression of coal spontaneous combustion. These findings provide important theoretical and practical guidance for the application of antioxidant gel foams in coal mine fire prevention and control, confirming that this material has great potential in coal mine fire safety, offering a new technological approach to improve coal mine safety. Full article
(This article belongs to the Special Issue Fire Prevention and Flame Retardant Materials)
Show Figures

Figure 1

18 pages, 4967 KiB  
Article
Effect of Pre-Damage on the Behavior of Axially and Eccentrically Compressed Concrete Cylinders Confined with PBO-FRCM
by Maciej Pazdan, Tomasz Trapko and Michał Musiał
Materials 2025, 18(12), 2881; https://doi.org/10.3390/ma18122881 - 18 Jun 2025
Viewed by 284
Abstract
In the case of strengthening building structures, the process usually involves elements that have a certain loading history and are typically subjected to loading during the strengthening process. In scientific research, on the other hand, strengthening is usually applied to elements that are [...] Read more.
In the case of strengthening building structures, the process usually involves elements that have a certain loading history and are typically subjected to loading during the strengthening process. In scientific research, on the other hand, strengthening is usually applied to elements that are not representative of real structures. This article presents a study of the effect of pre-damage on the behavior of eccentrically compressed concrete cylinders confined with PBO-FRCM (fabric-reinforced cementitious matrix with PBO fibers) composite. Concrete confinement introduces a favorable triaxial stress state, which leads to an increase in the compressive strength of concrete. FRCM systems are an alternative to FRP (fiber-reinforced polymer) composites. Replacing the polymer matrix with a mineral matrix primarily improves the fire resistance of the strengthening system. The elements were made of concrete with a compressive strength of about 40 MPa, which is typical for current reinforced concrete columns. Pre-damage was induced by loading the test elements to 80% of the average compressive strength and then fully unloading. The elements were then strengthened with three layers of PBO-FRCM composite and subjected to axial or eccentric compression with force applied at two different eccentricities. In addition to electric strain gauges, a digital image correlation system was used for measurements, to identify the initiation of PBO mesh overlap delamination. This study analyzed the elements in terms of load-bearing capacity, deformability, ductility, and failure mechanisms. In general, there was no negative effect of pre-damage on the behavior of the tested elements. Full article
(This article belongs to the Special Issue Strengthening, Repair, and Retrofit of Reinforced Concrete)
Show Figures

Figure 1

18 pages, 4962 KiB  
Article
Durability Assessment of Eco-Friendly Intumescent Coatings Based on Cork and Waste Glass Fillers for Naval Fire Safety
by Elpida Piperopoulos, Giuseppe Scionti, Mario Atria, Luigi Calabrese, Antonino Valenza and Edoardo Proverbio
Polymers 2025, 17(12), 1659; https://doi.org/10.3390/polym17121659 - 15 Jun 2025
Viewed by 481
Abstract
This research assessed novel, eco-friendly intumescent coatings utilizing cork and recycled glass as sustainable alternatives to synthetic fire retardants, aiming to reduce environmental impact while maintaining robust fire performance. Coatings underwent up to 600 h of UV light exposure for durability assessment, followed [...] Read more.
This research assessed novel, eco-friendly intumescent coatings utilizing cork and recycled glass as sustainable alternatives to synthetic fire retardants, aiming to reduce environmental impact while maintaining robust fire performance. Coatings underwent up to 600 h of UV light exposure for durability assessment, followed by chemo-physical characterization. Fire exposure tests evaluated in-situ char formation and foaming. All functionalized coatings exhibited suitable intumescent behavior, forming protective char layers even after extensive UV aging. Microscopic analysis showed good additive integration, while FTIR spectroscopy revealed UV-induced chemical changes. Fire resistance tests confirmed the superior performance of functionalized coatings over the commercial reference. The AP-IC system demonstrated the best intumescence, achieving significantly lower maximum temperatures (e.g., 167.3 °C for AP-IC-600) and heating rates. Crucially, the sustainable RG-IC and CK-IC batches showed promising intumescent properties, even improving with UV exposure. Notably, the foamed cross-sectional area of the aged RG-IC samples doubled compared to their unaged counterparts, reaching a maximum temperature of 166.9 °C. These findings highlight the potential of eco-friendly hybrid coatings to enhance fire safety, particularly in critical sectors like naval engineering, aligning with circular economy principles and the growing demand for sustainable, high-performance materials. Full article
(This article belongs to the Special Issue Recent Advances in Flame-Retardant Polymeric Materials)
Show Figures

Figure 1

30 pages, 5560 KiB  
Review
Post-Earthquake Fires (PEFs) in the Built Environment: A Systematic and Thematic Review of Structural Risk, Urban Impact, and Resilience Strategies
by Fatma Kürüm Varolgüneş and Sadık Varolgüneş
Fire 2025, 8(6), 233; https://doi.org/10.3390/fire8060233 - 13 Jun 2025
Viewed by 733
Abstract
Post-earthquake fires (PEFs) represent a complex, cascading hazard in which seismic damage creates ignition conditions that can overwhelm urban infrastructure and severely compromise structural integrity. Despite growing scholarly attention, the literature on PEFs remains fragmented across disciplines, lacking a consolidated understanding of structural [...] Read more.
Post-earthquake fires (PEFs) represent a complex, cascading hazard in which seismic damage creates ignition conditions that can overwhelm urban infrastructure and severely compromise structural integrity. Despite growing scholarly attention, the literature on PEFs remains fragmented across disciplines, lacking a consolidated understanding of structural vulnerabilities, urban-scale impacts, and response strategies. This study presents a systematic and thematic synthesis of 54 peer-reviewed articles, identified through a PRISMA-guided screening of 151 publications from the Web of Science Core Collection. By combining bibliometric mapping with thematic clustering, the review categorizes research into key methodological domains, including finite element modeling, experimental testing, probabilistic risk analysis, multi-hazard frameworks, urban simulation, and policy approaches. The findings reveal a dominant focus on structural fire resistance, particularly of seismically damaged concrete and steel systems, while highlighting emerging trends in sensor-based fire detection, AI integration, and urban resilience planning. However, critical research gaps persist in multi-hazard modeling, firefighting under partial collapse, behavioral responses, and the integration of spatial, infrastructural, and institutional factors. This study proposes an interdisciplinary research agenda that connects engineering, urban design, and disaster governance to inform adaptive, smart-city-based strategies for mitigating fire risks in seismic zones. This work contributes a comprehensive roadmap for advancing post-earthquake fire resilience in the built environment. Full article
Show Figures

Figure 1

Back to TopTop