Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

remove_circle_outline
remove_circle_outline
remove_circle_outline

Search Results (157)

Search Parameters:
Keywords = external thermal insulation systems

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
27 pages, 1091 KiB  
Review
Advances in Thermoregulating Textiles: Materials, Mechanisms, and Applications
by Kuok Ho Daniel Tang
Textiles 2025, 5(2), 22; https://doi.org/10.3390/textiles5020022 - 11 Jun 2025
Viewed by 1648
Abstract
Advancements in thermoregulating textiles have been propelled by innovations in nanotechnology, composite materials, and smart fiber engineering. This article reviews recent scholarly papers on experimental passive and active thermoregulating textiles to present the latest advancements in these fabrics, their mechanisms of thermoregulation, and [...] Read more.
Advancements in thermoregulating textiles have been propelled by innovations in nanotechnology, composite materials, and smart fiber engineering. This article reviews recent scholarly papers on experimental passive and active thermoregulating textiles to present the latest advancements in these fabrics, their mechanisms of thermoregulation, and their feasibility for use. The review underscores that phase-change materials enhanced with graphene, boron nitride, and carbon nanofibers offer superior thermal conductivity, phase stability, and flexibility, making them ideal for wearable applications. Shape-stabilized phase-change materials and aerogel-infused fibers have shown promising results in outdoor, industrial, and emergency settings due to their durability and high insulation efficiency. Radiative cooling textiles, engineered with hierarchical nanostructures and Janus wettability, demonstrate passive temperature regulation through selective solar reflection and infrared emission, achieving substantial cooling effects without external energy input. Thermo-responsive, shape-memory materials, and moisture-sensitive polymers enable dynamic insulation and actuation. Liquid-cooling garments and thermoelectric hybrids deliver precise temperature control but face challenges in portability and power consumption. While thermoregulating textiles show promise, the main challenges include achieving scalable manufacturing, ensuring material flexibility, and integrating multiple functions without sacrificing comfort. Future research should focus on hybrid systems combining passive and active mechanisms, user-centric wearability studies, and cost-effective fabrication methods. These innovations hold significant potential for applications in extreme environments, athletic wear, military uniforms, and smart clothing, contributing to energy efficiency, health, and comfort in a warming climate. Full article
Show Figures

Figure 1

25 pages, 1874 KiB  
Article
Performance Optimization of Building Envelope Through BIM and Multi-Criteria Analysis
by Stefano Cascone, Valeria Anastasi and Rosa Caponetto
Sustainability 2025, 17(12), 5294; https://doi.org/10.3390/su17125294 - 8 Jun 2025
Viewed by 620
Abstract
In response to the growing demand for sustainable and performance-driven building design, this study proposes an integrated digital methodology that combines Building Information Modeling (BIM), parametric scripting, and multi-criteria decision-making (MCDM) to optimize external wall assemblies. The approach leverages Autodesk Revit and Dynamo [...] Read more.
In response to the growing demand for sustainable and performance-driven building design, this study proposes an integrated digital methodology that combines Building Information Modeling (BIM), parametric scripting, and multi-criteria decision-making (MCDM) to optimize external wall assemblies. The approach leverages Autodesk Revit and Dynamo to automate the parametrization of insulation thickness while ensuring compliance with regulatory thresholds for thermal transmittance and surface mass. Acoustic performance is estimated using ECHO software, and a Weighted Sum Model (WSM) is applied to evaluate and rank configurations based on four criteria: economic cost, Global Warming Potential (GWP), embodied energy, and acoustic insulation. A case study involving 24 wall assemblies—generated from eight base stratigraphies and three insulation materials—demonstrates the method’s ability to balance environmental impact, occupant comfort, and construction feasibility. The results indicate that natural and bio-based materials, such as rammed earth and cork, offer the best overall performance, while conventional systems remain competitive in terms of cost. The proposed workflow reduces design time, increases transparency, and supports informed decision-making during early design stages. This research contributes to the digitalization of sustainability assessment in architecture by promoting integrative, replicable, and regulation-aligned practices for low-impact building envelopes. Full article
Show Figures

Figure 1

16 pages, 7389 KiB  
Technical Note
Design and Implementation of a Low-Cost Controlled-Environment Growth Chamber for Vegetative Propagation of Mother Plants
by Jacqueline Guerrero-Sánchez, Carlos Alberto Olvera-Olvera, Luis Octavio Solis-Sánchez, Ma. Del Rosario Martínez-Blanco, Manuel de Jesús López-Martínez, Celina Lizeth Castañeda-Miranda, Genaro Martin Soto-Zarazúa and Germán Díaz-Flórez
AgriEngineering 2025, 7(6), 177; https://doi.org/10.3390/agriengineering7060177 - 6 Jun 2025
Viewed by 982
Abstract
This Technical Note presents the design and implementation of a low-cost modular growth chamber developed to keep mother plants under controlled environmental conditions for vegetative propagation. The system was conceived as an accessible alternative to expensive commercial equipment, offering reproducibility and adaptability for [...] Read more.
This Technical Note presents the design and implementation of a low-cost modular growth chamber developed to keep mother plants under controlled environmental conditions for vegetative propagation. The system was conceived as an accessible alternative to expensive commercial equipment, offering reproducibility and adaptability for small-scale and research-based cultivation. The proposed chamber integrates thermal insulation, LED lighting, forced ventilation through the implementation of extractors, a recirculating irrigation system with double filtration, and a sensor-based environmental monitoring platform operated via an Arduino UNO microcontroller. The design features a removable tray that serves as a support for the mother plant, an observation window covered by a movable dark acrylic that prevents the passage of external light, and a vertical structure that facilitates optimal space utilization and ergonomic access. Functionality was conducted using a Stevia rebaudiana Bertoni mother plant maintained for 30 days under monitored conditions. Environmental parameters—temperature, relative humidity, and illuminance—were recorded continuously. The plant showed vegetative development through new shoot emergence and the growth in height of the plant, and despite a loss in foliage expansion, it confirmed the chamber’s capacity to support sustained growth. Although no statistical replication or control group was included in this preliminary evaluation, the system demonstrates technical feasibility and practical utility. This chamber provides a replicable platform for future experimentation and propagation studies. Complete technical specifications, schematics, and component lists are provided to enable replication and further development by other researchers. The growth chamber design aligns with the goals of open-source agricultural innovation and supports knowledge transfer in controlled-environment plant propagation technologies. Full article
Show Figures

Figure 1

50 pages, 4165 KiB  
Review
Sustainable Insulation Technologies for Low-Carbon Buildings: From Past to Present
by Pinar Mert Cuce
Sustainability 2025, 17(11), 5176; https://doi.org/10.3390/su17115176 - 4 Jun 2025
Viewed by 1088
Abstract
Building facade insulation technologies have evolved from primitive thermal barriers to high-performance, multifunctional systems that enhance energy efficiency and indoor comfort. Historical insulation methods, such as thick masonry walls and timber-based construction, have gradually been replaced by advanced materials and innovative facade designs. [...] Read more.
Building facade insulation technologies have evolved from primitive thermal barriers to high-performance, multifunctional systems that enhance energy efficiency and indoor comfort. Historical insulation methods, such as thick masonry walls and timber-based construction, have gradually been replaced by advanced materials and innovative facade designs. Studies indicate that a significant proportion of a building’s heat loss occurs through its external walls and windows, highlighting the need for effective insulation strategies. The development of double-skin facades (D-SFSs), adaptive facades (AFs), and green facades has enabled substantial reductions in heating and cooling energy demands. Materials such as vacuum insulation panels (VIPs), aerogels, and phase change materials (PCMs) have demonstrated superior thermal resistance, contributing to improved thermal regulation and reduced carbon emissions. Green facades offer additional benefits by lowering surface temperatures and mitigating urban heat island effects, while D-SF configurations can reduce cooling loads by over 20% in warm climates. Despite these advancements, challenges remain regarding the initial investment costs, durability, and material sustainability. The future of facade insulation technologies is expected to focus on bio-based and recyclable insulation materials, enhanced thermal performance, and climate-responsive facade designs. This study provides a comprehensive review of historical and modern facade insulation technologies, examining their impact on energy efficiency, sustainability, and future trends in architectural design. Full article
Show Figures

Figure 1

30 pages, 9217 KiB  
Article
Navigating Energy Efficiency and Mould Risk in Australian Low-Rise Homes: A Comparative Analysis of Nine External Wall Systems in Southeast Australia
by Liqun Guan, Mark Dewsbury, Louise Wallis and Hartwig Kuenzel
Energies 2025, 18(11), 2843; https://doi.org/10.3390/en18112843 - 29 May 2025
Viewed by 875
Abstract
As energy-efficient buildings become central to climate change mitigation, the opportunity for interior and interstitial moisture accumulation and mould growth can increase. This study investigated the potential simulation-based mould growth risks associated with the current generation of insulated low-rise timber framed external wall [...] Read more.
As energy-efficient buildings become central to climate change mitigation, the opportunity for interior and interstitial moisture accumulation and mould growth can increase. This study investigated the potential simulation-based mould growth risks associated with the current generation of insulated low-rise timber framed external wall systems within southeastern Australia. More than 8000 hygrothermal and bio-hygrothermal simulations were completed to evaluate seasonal moisture patterns and calculate mould growth potential for nine typical external wall systems. Results reveal that the combination of increased thermal insulation and air-tightness measures between the 2010 and 2022 specified building envelope energy efficiency regulations further increased predicted Mould Index values, particularly in cool-temperate climates. This was in part due to insufficient moisture management requirements, like an air space between the cladding and the weather resistive layer and/or the low-water vapour permeability of exterior weather resistive pliable membranes. By contrast, warmer temperate climates and drier cool-temperate climates exhibit consistently lower calculated Mould Index values. Despite the 2022 requirement for a greater water vapour-permeance of exterior pliable membranes, the external walls systems explored in this research had a higher calculated Mould Index than the 2010 regulatory compliant external wall systems. Lower air change rates significantly increased calculated interstitial mould growth risk, while the use of interior vapour control membranes proved effective in its mitigation for most external wall systems. The addition of ventilated cavity in combination with either or both an interior vapour control membrane and a highly vapour-permeable exterior pliable membranes further reduced risk. The findings underscore the need for tailored, climate-responsive design interventions to minimise surface and interstitial mould growth risk and building durability, whilst achieving high performance external wall systems. Full article
Show Figures

Figure 1

35 pages, 16910 KiB  
Article
A Simplified Model Validation for the Energy Assessment of Opaque Adaptive Façades with Variable Thermal Resistance
by Ismael Palacios Mackay, Laura Marín-Restrepo and Alexis Pérez-Fargallo
Energies 2025, 18(11), 2682; https://doi.org/10.3390/en18112682 - 22 May 2025
Viewed by 670
Abstract
Adaptive façades, also known as climate-adaptive building shells (CABSs), could make a significant contribution towards reducing the energy consumption of buildings and their environmental impacts. There is extensive research on glazed adaptive façades, mainly due to the available technology for glass materials. The [...] Read more.
Adaptive façades, also known as climate-adaptive building shells (CABSs), could make a significant contribution towards reducing the energy consumption of buildings and their environmental impacts. There is extensive research on glazed adaptive façades, mainly due to the available technology for glass materials. The technological development of opaque adaptive façades has focused on variable-thermal-resistance envelopes, and the simulation of this type of façade is a challenging task that has not been thoroughly studied. The aim of this study was to configure and validate a simplified office model that could be used for simulating an adaptive façade with variable thermal resistance via adaptive insulation thickness in its opaque part. Software-to-software model comparison based on the results of an EnergyPlus Building Energy Simulation Test 900 (BesTest 900)-validated model was used. Cooling and heating annual energy demand (kWh), peak cooling and heating (kW), and maximum, minimum, and average annual hourly zone temperature variables were compared for both the Adaptive and non-adaptive validated model. An Adaptive EnergyPlus model based on the BesTest 900 model, which uses the EnergyPlus SurfaceControl:MovableInsulation class list, was successfully validated and could be used for studying office buildings with a variable-thermal-resistance adaptive façade wall configuration, equivalent to a heavyweight mass wall construction with an External Insulation Finishing System (EIFS). An example of the Adaptive model in the Denver location is included in this paper. Annual savings of up to 26% in total energy demand (heating + cooling) was achieved and could reach up to 54% when electro-chromic (EC) glass commanded by a rule-based algorithm was added to the glazed part of the variable-thermal-resistance adaptive façade. Full article
(This article belongs to the Special Issue Advanced Building Materials for Energy Saving—2nd Edition)
Show Figures

Figure 1

25 pages, 7715 KiB  
Article
Thermal Performance Evaluation of a Retrofitted Building with Adaptive Composite Energy-Saving Facade Systems
by Nurlan Zhangabay, Arukhan Oner, Murat Rakhimov, Timur Tursunkululy and Uliya Abdikerova
Energies 2025, 18(6), 1402; https://doi.org/10.3390/en18061402 - 12 Mar 2025
Cited by 5 | Viewed by 919
Abstract
A possible way to solve the problem of energy saving in construction is to introduce energy-efficient buildings at the design stage and, in particular, during retrofit. Therefore, the purpose of this study is to conduct a theoretical analysis of thermal resistance and energy [...] Read more.
A possible way to solve the problem of energy saving in construction is to introduce energy-efficient buildings at the design stage and, in particular, during retrofit. Therefore, the purpose of this study is to conduct a theoretical analysis of thermal resistance and energy loads on a building in cold climatic conditions. The study of these values was carried out in the ANSYS software package and the Maple computer algebra system, respectively. This study examines four types of structures: the existing facade of a building constructed in 1966, a traditional ventilated facade, and two designs featuring alternating insulation layers with enclosed air channels and with or without heat-reflecting screens in the insulation layer. The results of this study show that the new design incorporating heat-reflecting screens in the insulation layer is 1.15 times more energy-efficient in terms of thermal resistance than the proposed design without such screens. The effectiveness of the proposed new design with heat-reflecting screens in the insulation layer is also confirmed through an analysis of the thermal protection of the building, where the auxiliary indicators, specific characteristics, and complex values of energy efficiency and energy load of the building show greater efficiencies of 1.6, 1.03, and 1.05 times, respectively, compared to the other studied structures. The comprehensive research results presented in this study indicate that the use of energy-efficient wall structures for the retrofit of external enclosures can significantly improve the thermal performance of buildings. It was also determined that the use of such wall structures can significantly enhance the building’s overall energy efficiency rating. The findings of this study highlight that the proposed solutions can contribute to significant energy savings in buildings, while the newly developed structures can serve as valuable additions to the existing catalog of energy-efficient external wall designs. Full article
(This article belongs to the Section G: Energy and Buildings)
Show Figures

Figure 1

25 pages, 9363 KiB  
Article
Globalization and Architecture: Urban Homogenization and Challenges for Unprotected Heritage. The Case of Postmodern Buildings with Complex Geometric Shapes in the Ensanche of San Sebastián
by María Senderos, Maialen Sagarna, Juan Pedro Otaduy and Fernando Mora
Buildings 2025, 15(3), 497; https://doi.org/10.3390/buildings15030497 - 5 Feb 2025
Cited by 3 | Viewed by 2945
Abstract
Globalization has profoundly impacted architecture by promoting urban homogenization, where global styles and materials overshadow local character. This shift prioritizes standardized functionality and energy efficiency over cultural identity, erasing regional architectural distinctiveness. In historical urban centers, globalization-driven interventions—such as ventilated facades or external [...] Read more.
Globalization has profoundly impacted architecture by promoting urban homogenization, where global styles and materials overshadow local character. This shift prioritizes standardized functionality and energy efficiency over cultural identity, erasing regional architectural distinctiveness. In historical urban centers, globalization-driven interventions—such as ventilated facades or external thermal insulation systems (ETISs)—often simplify original compositions and alter building materiality, texture, and color. The Ensanche of San Sebastián serves as a case study highlighting this issue. Despite its architectural richness, which includes neoclassical and modernist buildings primarily constructed with sandstone from the Igeldo quarry, unprotected buildings are at risk of unsympathetic renovations. Such changes can distort the identity of what is considered “everyday heritage”, encompassing the residential buildings and public spaces that shape the collective memory of cities. This study presents a replicable methodology for assessing the vulnerability of buildings to facade interventions. By utilizing tools like digital twins, point cloud modeling, and typological analysis, the research establishes criteria for interventions aimed at preserving architectural values. It emphasizes the importance of collaborative efforts with urban planning authorities and public awareness campaigns to safeguard heritage. Ultimately, protecting architectural identity requires balancing the goals of energy efficiency with cultural preservation. This approach ensures that urban landscapes maintain their historical and social significance amidst globalization pressures. Full article
(This article belongs to the Special Issue Selected Papers from the REHABEND 2024 Congress)
Show Figures

Figure 1

14 pages, 9128 KiB  
Article
Determining Moisture Condition of External Thermal Insulation Composite System (ETICS) of an Existing Building
by Paweł Krause, Iwona Pokorska-Silva and Łukasz Kosobucki
Materials 2025, 18(3), 614; https://doi.org/10.3390/ma18030614 - 29 Jan 2025
Viewed by 932
Abstract
ETICS is a popular external wall insulation system, which is not without possible defects and damages. A frequent cause, direct or indirect, of damage to buildings is the impact of water (moisture). This article presents, among others, the results of tests of the [...] Read more.
ETICS is a popular external wall insulation system, which is not without possible defects and damages. A frequent cause, direct or indirect, of damage to buildings is the impact of water (moisture). This article presents, among others, the results of tests of the moisture content of ETICS layers, the water absorption and capillary absorption of the render by means of the Karsten tube method, numerical thermo-moisture simulations, and tests of interlayer adhesion, in sample residential buildings. Mass moisture content testing of the wall substrate showed acceptable moisture levels (1–4%m) within masonry walls made of silicate blocks, as well as locally elevated moisture levels (4–8%m) in the case of reinforced concrete walls. Moisture testing of the insulation samples showed a predominantly dry condition, and testing of the reinforcement layer showed an acceptable level of moisture. Severe moisture was found in the sample taken in the ground-floor zone at the interface between mineral wool and EPS-P insulation underneath the reinforced layer. Capillary water absorption tests helped classify silicone render as an impermeable and surface hydrophobic coating. Tests of the water absorption of the facade plaster showed that the value declared by the manufacturer (<0.5 kg/m2) was mostly met (not in the ground-floor zone). The simulation calculations gave information that there was no continuous increase in condensation during the assumed analysis time (the influence of interstitial condensation on the observed anomalies was excluded). The tests carried out indicated the occurrence of numerous errors in the implementation of insulation works affecting the moisture content and durability of external partitions. Full article
(This article belongs to the Section Construction and Building Materials)
Show Figures

Figure 1

14 pages, 5152 KiB  
Article
Fire Performance Comparison of Expanded Polystyrene External Thermal Insulation Composites Systems and Expandable Graphite-Modified Surface Covers at Different Scales
by Mingwei Tang, Serge Bourbigot, Thomas Rogaume, Tsilla Bensabath, Benjamin Batiot and Virginie Drean
Fire 2025, 8(2), 45; https://doi.org/10.3390/fire8020045 - 25 Jan 2025
Viewed by 1294
Abstract
Numerous fire disasters have involved thermoplastic expanded polystyrene (EPS) external thermal insulation composite systems (ETICS) on building façades. This study evaluates the flame-retardant efficiency of expandable graphite (EG)-blended EPS ETICS across different scales: micro-scale thermogravimetric (TG) analysis, small-scale bench tests, and large-scale LEPIR [...] Read more.
Numerous fire disasters have involved thermoplastic expanded polystyrene (EPS) external thermal insulation composite systems (ETICS) on building façades. This study evaluates the flame-retardant efficiency of expandable graphite (EG)-blended EPS ETICS across different scales: micro-scale thermogravimetric (TG) analysis, small-scale bench tests, and large-scale LEPIR 2 tests. TG analysis confirmed EG’s primary role as a physical intumescent, with no significant chemical interactions detected. While EG effectively reduced heat penetration in both small-scale and large-scale fire tests, challenges arose from char layer detachment and oxidation at elevated temperatures (exceeding 540 °C). Despite these limitations, the EG-treated façade exhibited significantly lower peak temperatures compared to the untreated control in the large-scale LEPIR 2 test, with a measured temperature difference of approximately 470 °C. These findings demonstrate the potential of EG to enhance the fire safety of EPS ETICS. The small-scale test bench proved effective for preliminary material screening, providing valuable insights into ignition resistance and flame-retardant properties before proceeding to more resource-intensive large-scale evaluations. Full article
(This article belongs to the Special Issue Fire Prevention and Flame Retardant Materials)
Show Figures

Figure 1

11 pages, 3987 KiB  
Article
A Rectangular Spiral Inward–Outward Alternating-Flow Polymer Thermal Collector for a Solar Water Heating System—A Preliminary Investigation in the Climate of Seri Iskandar, Malaysia
by Taib Iskandar Mohamad and Mohammad Danish Shareeman Mohd Shaifudeen
Appl. Sci. 2024, 14(23), 11045; https://doi.org/10.3390/app142311045 - 27 Nov 2024
Cited by 1 | Viewed by 1153
Abstract
A flat-plate unglazed solar water heater (SWH) with a polymer thermal absorber was developed and experimented with. Polymer thermal absorbers could be a viable alternative to metal thermal absorbers for SWH systems. The performance of this polymer SWH system was measured based on [...] Read more.
A flat-plate unglazed solar water heater (SWH) with a polymer thermal absorber was developed and experimented with. Polymer thermal absorbers could be a viable alternative to metal thermal absorbers for SWH systems. The performance of this polymer SWH system was measured based on inlet and outlet water temperature, water flow rate, ambient air temperature and solar irradiance. The polymer thermal absorbers were hollow Polyvinyl Chloride (PVC) tubes with a 20 mm external diameter and 3 mm thickness and were painted black to enhance radiation absorption. The pipes are arranged in a rectangular spiral inward–outward alternating-flow (RSioaf) pattern. The collector pipes were placed in a 1 m × 1 m enclosure with bottom insulation and a reflective surface for maximized radiation absorption. Water circulated through a closed loop with an uninsulated 16 L storage tank, driven by a pump and controlled by two valves to maintain a mass flow rate of 0.0031 to 0.0034 kg·s−1. The test was conducted under a partially clouded sky from 9 a.m. to 5 p.m., with solar irradiance between 105 and 1003 W·m−2 and an ambient air temperature of 27–36 °C. This SWH system produced outlet hot water at 65 °C by midday and maintained the storage temperature at 63 °C until the end of the test period. Photothermal energy conversion was recorded, showing a maximum value of 23%. Results indicate that a flat-plate solar water heater with a polymer thermal absorber in an RSioaf design can be an effective alternative to an SWH with a metal thermal absorber. Its performance can be improved with glazing and optimized tube sizing. Full article
(This article belongs to the Special Issue Advanced Solar Energy Materials: Methods and Applications)
Show Figures

Figure 1

13 pages, 1570 KiB  
Article
Assessment of the Aging State for Transformer Oil-Barrier Insulation by Raman Spectroscopy and Optimized Support Vector Machine
by Deliang Liu, Biao Lu, Wenping Wu, Wei Zhou, Wansu Liu, Yiye Sun, Shilong Wu, Guolong Shi and Leiming Yuan
Sensors 2024, 24(23), 7485; https://doi.org/10.3390/s24237485 - 24 Nov 2024
Viewed by 1649
Abstract
Accurate assessment of the aging state of transformer oil-barrier insulation is crucial for ensuring the safe and reliable operation of power systems. This study presents the development of indoor accelerated thermal aging experiments to simulate the degradation of oil-immersed barrier insulation within transformers. [...] Read more.
Accurate assessment of the aging state of transformer oil-barrier insulation is crucial for ensuring the safe and reliable operation of power systems. This study presents the development of indoor accelerated thermal aging experiments to simulate the degradation of oil-immersed barrier insulation within transformers. A series of samples reflecting various aging states was obtained and categorized into six distinct groups. Raman spectroscopy analytical technology was employed to characterize the information indicative of different aging states of the oil-immersed barrier insulation. The raw Raman spectra were processed using asymmetric reweighted penalty least squares to correct baseline shifts, Savitzky–Golay (S-G) smoothing to eliminate fluctuation noise, and principal component analysis (PCA) to reduce data dimensionality by extracting principal components. A support vector machine (SVM) classifier was developed to discriminate between the Raman spectra and category labels. The SVM parameters were optimized using grid search, particle swarm optimization (PSO), and genetic algorithm (GA), yielding the optimal parameters (C and gamma). Notably, the grid search method demonstrated high efficiency in identifying the best combination of SVM parameters (c and g). Comparative analyses with varying numbers of principal components in SVM classifiers revealed that incorporating an optimal subset of PCA features achieved the highest classification accuracy of 94.44% for external validation samples, with only eight samples being misclassified into adjacent categories. This study offers technical support and a theoretical foundation for the effective assessment of the aging state of oil-barrier type insulation in transformers, contributing to the advancement of condition monitoring and maintenance strategies in power systems. Full article
(This article belongs to the Section Physical Sensors)
Show Figures

Figure 1

14 pages, 8788 KiB  
Article
A Case Study of 3D Scanning Techniques in Civil Engineering Using the Terrestrial Laser Scanning Technique
by Artur Piekarczuk, Aleksandra Mazurek, Jacek Szer and Iwona Szer
Buildings 2024, 14(12), 3703; https://doi.org/10.3390/buildings14123703 - 21 Nov 2024
Cited by 3 | Viewed by 2538
Abstract
This paper reviews the measurement challenges associated with 3D scanning techniques in civil engineering, exploring the practical aspects of scanning buildings and complex surfaces through various case studies. The paper details the conventional use of Terrestrial Laser Scanning (TLS) for reconstructing the technical [...] Read more.
This paper reviews the measurement challenges associated with 3D scanning techniques in civil engineering, exploring the practical aspects of scanning buildings and complex surfaces through various case studies. The paper details the conventional use of Terrestrial Laser Scanning (TLS) for reconstructing the technical documentation of a hall. Then it describes an unconventional application of this technique for measuring an External Thermal Insulation Composite System (ETICS) wall, aimed at detecting microdeformations caused by environmental factors controlled within a climatic chamber. Subsequently, the measurements of the insulated wall were repeated using a metrological grade laser scanner. The numerical data were analysed with inspection engineering methods. The deformation maps and displacements of selected reference points were compared. This approach yielded qualitative and quantitative results. The qualitative results, i.e., the distribution of deformations in the form of a map, turned out to be consistent. However, quantitative results show a significant discrepancy in extreme cases of up to 70%. Full article
(This article belongs to the Section Construction Management, and Computers & Digitization)
Show Figures

Figure 1

25 pages, 7729 KiB  
Article
A Fast-Calibrated Computational Fluid Dynamic Model for Timber–Concrete Composite Ventilated Façades
by Sofia Pastori, Mohammed-Sadegh Salehi, Stefan Radl and Enrico Sergio Mazzucchelli
Buildings 2024, 14(11), 3567; https://doi.org/10.3390/buildings14113567 - 9 Nov 2024
Viewed by 1047
Abstract
Timber–concrete composite (TCC) systems join the positive aspects of engineered wood products (good seismftaic behaviour, low thermal conductivity, environmental sustainability, good behaviour under fire if appropriately designed) with those of concrete (high thermal inertia, durability, excellent fire resistance). TCC facades are typically composed [...] Read more.
Timber–concrete composite (TCC) systems join the positive aspects of engineered wood products (good seismftaic behaviour, low thermal conductivity, environmental sustainability, good behaviour under fire if appropriately designed) with those of concrete (high thermal inertia, durability, excellent fire resistance). TCC facades are typically composed of an internal insulated timber-frame wall and an external concrete slab, separated by a ventilated air cavity. However, there is very limited knowledge concerning the performance of TCC facades, especially concerning their thermal behaviour. The present paper deals with the development and optimization of a 2D Computational Fluid Dynamic (CFD) model for the analysis of TCC ventilated façades’ thermal behaviour. The model is calibrated and validated against experimental data collected during the annual monitoring of a real TCC ventilated envelope in the north of Italy. Also, a new solver algorithm is developed to significantly speed up the simulation (i.e., 45 times faster simulation at an error below 3.5 °C compared to a typical CFD solver). The final model can be used for the time-efficient analysis (simulation time of approximately 23 min for a full day in real-time) and the optimization of the thermal performance of TCC ventilated facades, as well as other ventilated facades with external massive cladding. Our simulation strategy partially avoids the expensive and time-consuming construction of mock-ups, or the use of comparably slow (conventional) CFD solvers that are less suitable for optimization studies. Full article
(This article belongs to the Special Issue Thermal Fluid Flow and Heat Transfer in Buildings)
Show Figures

Figure 1

21 pages, 3075 KiB  
Article
Façade Retrofit Strategies for Energy Efficiency Improvement Considering the Hot Climatic Conditions of Saudi Arabia
by Wesam Rababa and Omar S. Asfour
Appl. Sci. 2024, 14(21), 10003; https://doi.org/10.3390/app142110003 - 1 Nov 2024
Cited by 4 | Viewed by 2325
Abstract
Saudi Arabia faces significant challenges in managing the rising energy consumption in buildings driven largely by its hot climatic conditions. As a result, retrofitting building facades to enhance energy efficiency has become a critical strategy. This study assesses the effectiveness of various façade [...] Read more.
Saudi Arabia faces significant challenges in managing the rising energy consumption in buildings driven largely by its hot climatic conditions. As a result, retrofitting building facades to enhance energy efficiency has become a critical strategy. This study assesses the effectiveness of various façade retrofit strategies in reducing cooling electricity consumption using a real-time case study in Dhahran, Saudi Arabia. The strategies explored include external wall upgrades, window replacements, and installation of shading devices. Each strategy was evaluated individually, considering the reduction in heat gains, cooling load, and payback period as key performance indicators. To further maximize energy efficiency, these strategies were also analyzed in combination using the genetic algorithm optimization method, yielding 224 possible facade configurations. The optimal solution included the use of an External Thermal Insulation Composite System (ETCIS) in walls, louvers in windows, and low-emissivity coating with Argon gas-filled glazing, achieving a cooling energy reduction of approximately 16% and a payback period of 14.8 years. This study provides several recommendations for improving the efficiency of retrofitting building façades in hot climatic conditions. Full article
Show Figures

Figure 1

Back to TopTop