Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (27)

Search Parameters:
Keywords = esophageal catheter

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
16 pages, 3858 KiB  
Article
Feasibility and Safety of Endoscopic Balloon-Assisted Laser Treatment (EBLT) for Gastroesophageal Reflux Disease: Functional, Structural, and Gene Expression Analysis in Preclinical Model
by Boram Cha, Hyejin Kim, Van Gia Truong, Sun-Ju Oh, Seok Jeong and Hyun Wook Kang
Photonics 2025, 12(5), 421; https://doi.org/10.3390/photonics12050421 - 28 Apr 2025
Viewed by 512
Abstract
Gastroesophageal reflux disease (GERD) is a prevalent disorder caused by lower esophageal sphincter (LES) dysfunction, often requiring long-term treatment. This study assessed the feasibility of endoscopic balloon-assisted laser treatment (EBLT) using a porcine GERD model. One week after GERD induction, EBLT was performed [...] Read more.
Gastroesophageal reflux disease (GERD) is a prevalent disorder caused by lower esophageal sphincter (LES) dysfunction, often requiring long-term treatment. This study assessed the feasibility of endoscopic balloon-assisted laser treatment (EBLT) using a porcine GERD model. One week after GERD induction, EBLT was performed on three animals, while one served as a control. A 980 nm continuous-wave laser was delivered at 30 W for 90 s (energy = 2700 J and power density = 2.17 W/cm2) in a circumferential, non-contact manner using a balloon-assisted catheter. Real-time mucosal temperature monitoring was achieved using a fiber Bragg grating (FBG) sensor integrated with the balloon, maintaining temperatures below 40 °C. Endoscopic ultrasound and manometry were used to evaluate LES thickness and pressure before and after treatment. After a 12-week observation period, esophageal tissues were harvested for histological and gene expression analysis. Compared to the control, the treated group showed an increase in LES thickness (3.6 ± 0.2 mm vs. 1.5 mm) and relative LES pressure changes (2.9 ± 1.6 vs. 0.6). Upregulation of fibrosis- and hypertrophy-related genes suggested structural remodeling of the LES. No adverse effects or mucosal injury were observed. These findings support EBLT as a promising and minimally invasive strategy for GERD treatment. Full article
Show Figures

Figure 1

12 pages, 1143 KiB  
Article
Continuous Epidural Versus Non-Epidural Pain Management After Minimally Invasive Esophagectomy: A Real-Life, High-Case-Load Center Experience
by Sebastian Boehler, Markus Huber, Patrick Y. Wuethrich, Christian M. Beilstein, Stefano M. Arigoni, Marc A. Furrer, Yves Borbély and Dominique Engel
J. Clin. Med. 2024, 13(24), 7669; https://doi.org/10.3390/jcm13247669 - 16 Dec 2024
Cited by 2 | Viewed by 952
Abstract
Background/Objectives: Esophagectomy is a key component of esophageal cancer treatment, with minimally invasive esophagectomy (MIE) increasingly replacing open esophagectomy (OE). Effective postoperative pain management can be achieved through various analgesic modalities. This study compares the efficacy of thoracic epidural anesthesia (TEA) with [...] Read more.
Background/Objectives: Esophagectomy is a key component of esophageal cancer treatment, with minimally invasive esophagectomy (MIE) increasingly replacing open esophagectomy (OE). Effective postoperative pain management can be achieved through various analgesic modalities. This study compares the efficacy of thoracic epidural anesthesia (TEA) with non-TEA methods in managing postoperative pain following MIE. Methods: A retrospective review was conducted on 110 patients who underwent MIE between 2018 and 2023. 1. TEA vs. 2. intravenous patient-controlled analgesia (PCA) alone vs. 3. transversus abdominis plane (TAP) catheter with PCA vs. 4. single-shot TAP block with paravertebral catheter (PVB) in combination with PCA were compared. The primary outcome was postoperative pain within the first 72 h, assessed using the numeric rating scale. Secondary outcomes included postoperative surgical complications (Clavien–Dindo classification (CDC)), patient satisfaction, and duration of induction and emergence, among others. Results: The incidence of an NRS > 3 during movement was 47.1%, 51%, 60.1%, and 48.3% for TEA, PCA alone, TAP + PCA, and PVB + PCA, respectively. For pain at rest, the rates were 8.3%, 4.3%, 11.2%, and 5%, respectively. High surgical complication rates were observed across all groups (CDC IIIa-V 31.6% overall), with patient satisfaction similarly high, regardless of the analgesic modality used (85% satisfied or very satisfied). No differences in the other secondary outcomes were observed. Conclusions: PVB combined with PCA offered analgesic efficacy and patient satisfaction comparable to TEA in managing postoperative pain following MIE. Full article
(This article belongs to the Section Anesthesiology)
Show Figures

Figure 1

13 pages, 3410 KiB  
Article
Comparative Analysis of Real-World Clinical Outcomes of a Novel Pulsed Field Ablation System for Pulmonary Vein Isolation: The Prospective CIRCLE-PVI Study
by Lyuboslav Katov, Yannick Teumer, Carlo Bothner, Wolfgang Rottbauer and Karolina Weinmann-Emhardt
J. Clin. Med. 2024, 13(23), 7040; https://doi.org/10.3390/jcm13237040 - 21 Nov 2024
Cited by 2 | Viewed by 2275
Abstract
Background: Pulsed field ablation (PFA) represents a novel non-thermal approach for treating atrial fibrillation (AF) through pulmonary vein isolation (PVI). By utilizing irreversible electroporation, PFA creates lesions with minimal impact on adjacent tissues. This study investigates the procedural outcomes and safety of a [...] Read more.
Background: Pulsed field ablation (PFA) represents a novel non-thermal approach for treating atrial fibrillation (AF) through pulmonary vein isolation (PVI). By utilizing irreversible electroporation, PFA creates lesions with minimal impact on adjacent tissues. This study investigates the procedural outcomes and safety of a novel circular PFA catheter in comparison to an established PFA system in a real-world clinical setting. Methods: This prospective, single-center study enrolled 125 consecutive patients with symptomatic paroxysmal or persistent AF undergoing first-time PVI with PFA at Ulm University Heart Center. Twenty-five patients underwent PFA PVI using a novel PFA system (PulseSelectTM, Medtronic, Dublin, Ireland) which incorporates a new circular catheter design and additional features such as ECG-triggered energy application and phrenic nerve capture testing. In comparison, 100 patients were treated using the established PFA system (FarapulseTM, Boston Scientific, Marlborough, MA, USA). Results: Acute PVI was achieved in 100% of the patients. Procedure duration, total left atrial (LA) time and fluoroscopy time remained comparable between both groups. The total number of energy deliveries was higher with the novel circular PFA catheter (34.0 vs. 32.0; p < 0.001). No procedure-related complications, including pericardial tamponade, phrenic nerve injury, atrial-esophageal fistula, vascular complications, embolisms, malignant cardiac arrhythmias, or coronary spasms were observed. Conclusions: The novel and the established PFA systems demonstrated comparable results in terms of procedure duration, fluoroscopy time, and LA time. In the hands of experienced operators, the novel circular PFA system enables an effective, consistent, and safe approach to successful PFA PVI. Full article
Show Figures

Figure 1

10 pages, 857 KiB  
Article
Sedation and Endoscopy-Assisted High-Resolution Manometry (SEA-HRM) in Patients Who Previously Failed Standard Esophageal Manometry
by Daniel L. Cohen, Eyal Avivi, Sergei Vosko, Vered Richter, Haim Shirin and Anton Bermont
Diagnostics 2024, 14(19), 2232; https://doi.org/10.3390/diagnostics14192232 - 6 Oct 2024
Cited by 2 | Viewed by 1710
Abstract
Objectives: Esophageal high-resolution manometry (HRM) is the gold standard for diagnosing esophageal motility disorders, but it may be poorly tolerated and unsuccessful. We sought to evaluate a protocol for sedation and endoscopy-assisted (SEA) HRM in patients who previously failed standard HRM and assess [...] Read more.
Objectives: Esophageal high-resolution manometry (HRM) is the gold standard for diagnosing esophageal motility disorders, but it may be poorly tolerated and unsuccessful. We sought to evaluate a protocol for sedation and endoscopy-assisted (SEA) HRM in patients who previously failed standard HRM and assess patient perspectives towards it. Methods: Adult patients who previously failed HRM were prospectively enrolled. Under propofol sedation, an upper endoscopy was performed during which the HRM catheter was advanced under endoscopic visualization. If the catheter did not reach the stomach on its own, the endoscope itself or a snare was used to help it traverse the esophagogastric junction (EGJ). Results: Thirty patients participated (mean age 67.8, 70% female). The technical success of SEA-HRM was 100%. Twenty-two (73.3%) were diagnosed with a motility disorder including thirteen (43.3%) with achalasia. Eighteen (60%) had previously failed HRM due to discomfort/intolerance, while twelve (40%) failed due to catheter coiling in the esophagus. Subjects in the coiling group were more likely to need endoscopic assistance to traverse the EGJ (91.7% vs. 27.7%, p = 0.001) and have a motility disorder (100.0% vs. 55.6%, p = 0.010), including achalasia (75.0% vs. 22.2%, p = 0.004), compared to the discomfort/intolerance group. All patients preferred SEA-HRM and rated it higher than standard HRM (9.5 ± 1.3 vs. 1.9 ± 2.1, p = <0.001, on a scale of 1–10). Conclusions: SEA-HRM is a highly successful and well-tolerated option in patients who previously failed standard HRM. This should be the recommended approach in cases of failed HRM rather than secondary tests of esophageal motility. Full article
(This article belongs to the Special Issue Gastrointestinal Motility Disorders: Diagnosis and Management)
Show Figures

Figure 1

22 pages, 330 KiB  
Review
Pulsed Field Energy in Atrial Fibrillation Ablation: From Physical Principles to Clinical Applications
by Nicola Pierucci, Marco Valerio Mariani, Domenico Laviola, Giacomo Silvetti, Pietro Cipollone, Antonio Vernile, Sara Trivigno, Vincenzo Mirco La Fazia, Agostino Piro, Fabio Miraldi, Carmine Dario Vizza and Carlo Lavalle
J. Clin. Med. 2024, 13(10), 2980; https://doi.org/10.3390/jcm13102980 - 18 May 2024
Cited by 10 | Viewed by 4503
Abstract
Atrial fibrillation, representing the most prevalent sustained cardiac arrhythmia, significantly impacts stroke risk and cardiovascular mortality. Historically managed with antiarrhythmic drugs with limited efficacy, and more recently, catheter ablation, the interventional approach field is still evolving with technological advances. This review highlights pulsed [...] Read more.
Atrial fibrillation, representing the most prevalent sustained cardiac arrhythmia, significantly impacts stroke risk and cardiovascular mortality. Historically managed with antiarrhythmic drugs with limited efficacy, and more recently, catheter ablation, the interventional approach field is still evolving with technological advances. This review highlights pulsed field ablation (PFA), a revolutionary technique gaining prominence in interventional electrophysiology because of its efficacy and safety. PFA employs non-thermal electric fields to create irreversible electroporation, disrupting cell membranes selectively within myocardial tissue, thus preventing the non-selective damage associated with traditional thermal ablation methods like radiofrequency or cryoablation. Clinical studies have consistently shown PFA’s ability to achieve pulmonary vein isolation—a cornerstone of AF treatment—rapidly and with minimal complications. Notably, PFA reduces procedure times and has shown a lower incidence of esophageal and phrenic nerve damage, two common concerns with thermal techniques. Emerging from oncological applications, the principles of electroporation provide a unique tissue-selective ablation method that minimizes collateral damage. This review synthesizes findings from foundational animal studies through to recent clinical trials, such as the MANIFEST-PF and ADVENT trials, demonstrating PFA’s effectiveness and safety. Future perspectives point towards expanding indications and refinement of techniques that promise to improve AF management outcomes further. PFA represents a paradigm shift in AF ablation, offering a safer, faster, and equally effective alternative to conventional methods. This synthesis of its development and clinical application outlines its potential to become the new standard in AF treatment protocols. Full article
(This article belongs to the Special Issue Advances in Cardiac Electrophysiology and Pacing: Part II)
9 pages, 1896 KiB  
Article
Assessment of Esophageal Shifts during Catheter Ablation of Atrial Fibrillation Using Intracardiac Ultrasound Integrated with 3-Dimensional Electroanatomical Mapping System
by Andrej Pernat, Mark Zavrtanik, Antonio Gianluca Robles, Silvio Romano, Luigi Sciarra and Bor Antolič
J. Cardiovasc. Dev. Dis. 2024, 11(4), 110; https://doi.org/10.3390/jcdd11040110 - 31 Mar 2024
Viewed by 1635
Abstract
Purpose: Atrioesophageal fistula is one of the most feared complications of radiofrequency catheter ablation (RFCA) of atrial fibrillation (AF) as it is associated with high mortality. Determining the esophagus location during RFCA might reduce the risk of esophageal injury. The present study aims [...] Read more.
Purpose: Atrioesophageal fistula is one of the most feared complications of radiofrequency catheter ablation (RFCA) of atrial fibrillation (AF) as it is associated with high mortality. Determining the esophagus location during RFCA might reduce the risk of esophageal injury. The present study aims to evaluate the feasibility of using intracardiac echocardiography integrated into a 3-dimensional electroanatomical mapping system (ICE/3D EAM) for the assessment of esophageal position and shifts in response to ablation. Methods: We prospectively enrolled 20 patients that underwent RFCA of AF under conscious analgosedation. The virtual anatomy of the left atrium, the pulmonary vein (PV) ostia, and the esophagus was created with ICE/3D EAM. The esophageal positions were obtained at the beginning of the procedure and then after left and right PV isolation (PVI). Esophageal shifts were measured offline after the procedure using the tools available in the 3D EAM system. Results: Most esophagi moved away from the ablated PV ostia. After the left PVI, the median of the shifts was 2.8 mm (IQR 1.0–6.3). In 25% of patients, the esophagus shifted by >5.0 mm (max. 13.4 mm). After right PVI, the median of shifts was 2.0 mm (IQR 0.7–4.9). In 10% of patients, the esophageal shift was >5.0 mm (max. 7.8 mm). Conclusions: ICE/3D EAM enables the intraprocedural visualization of baseline esophageal position and its shifts after PVI. The shifts are variable, but they tend to be small and directed away from the ablation site. Repeated intraprocedural visualization of the esophagus may be needed to reduce the risk of esophageal injury. Full article
Show Figures

Figure 1

18 pages, 3012 KiB  
Article
Left Atrial Posterior Wall Isolation with Pulsed Field Ablation in Persistent Atrial Fibrillation
by Melanie A. Gunawardene, Gerrit Frommeyer, Christian Ellermann, Mario Jularic, Patrick Leitz, Jens Hartmann, Philipp Sebastian Lange, Omar Anwar, Benjamin Rath, Rahin Wahedi, Lars Eckardt and Stephan Willems
J. Clin. Med. 2023, 12(19), 6304; https://doi.org/10.3390/jcm12196304 - 29 Sep 2023
Cited by 30 | Viewed by 4229
Abstract
Background: Left atrial posterior wall isolation (LAPWI) may improve rhythm control in addition to pulmonary vein isolation (PVI) in persistent atrial fibrillation (persAF) patients undergoing catheter ablation (CA). However, LAPWI may be challenging when using thermal energy sources. Objective: This study aimed to [...] Read more.
Background: Left atrial posterior wall isolation (LAPWI) may improve rhythm control in addition to pulmonary vein isolation (PVI) in persistent atrial fibrillation (persAF) patients undergoing catheter ablation (CA). However, LAPWI may be challenging when using thermal energy sources. Objective: This study aimed to investigate the efficacy and safety of LAPWI performed by non-thermal pulsed field ablation (PFA) in CA for persAF. Methods: Consecutive persAF patients from two German centers were prospectively enrolled. There were two study cohorts: (1) the LAPWI cohort, which included PFA-guided (re-)PVI with LAPWI for first-time and/or repeat ablation procedures; and (2) a comparative persAF cohort with a PFA PVI-only approach without LAPWI for first-time ablation within the same timeframe. Patients were followed up by routine Holter ECGs. Results: In total, 79 persistent AF patients were included in the study: 59/79 patients were enrolled in the LAPWI cohort, including 16/59 index (27%) and 43/59 repeat ablation procedures (73%). Sixteen patients (16/79; 21%) were in the PVI-only cohort without LAPWI. Of the patients treated with LAPWI, procedure time and fluoroscopy time was 91 ± 30 min and 15 ± 7 min, respectively. The acute PVI rate was 100% in all first-time ablation patients (32 patients (16 PVI only, 16 PVI plus LAPWI), 196/196 PVs). Of the 43 re-do patients in the LAPWI cohort, re-PVI was necessary in 33% (14/43) of patients (27 PVs; 1.9 PV per-patient); in 67% (29/43), all PVs were isolated, and antral ablation of the PV ostia was performed in 48% (14/29). LAPWI was performed successfully in all 59 (100%) patients of the LAPWI cohort. Two minor complications occurred. No esophageal lesion was detected in the LAPWI cohort (n = 33/59 (56%) patients underwent endoscopy). After 354 ± 197 days of follow-up, freedom from atrial arrhythmias was 79.3% (95-CI: 62–95%) in the complete LAPWI cohort (n = 14/59 (24%) on AAD: class Ic n = 9, class III n = 5). There was no difference regarding acute procedural and clinical outcome compared to the PVI-only cohort. Conclusion: LAPWI guided by PFA is feasible and safe in patients undergoing CA for persAF and shows favorable outcomes. In the context of durable PVI, PFA-guided LAPWI may be an effective adjunctive treatment option. Full article
(This article belongs to the Special Issue New Ablation Techniques for Atrial Fibrillation)
Show Figures

Graphical abstract

25 pages, 4847 KiB  
Article
Development and Evaluation of a Flexible PVDF-Based Balloon Sensor for Detecting Mechanical Forces at Key Esophageal Nodes in Esophageal Motility Disorders
by Peng Ran, Minchuan Li, Kunlin Zhang, Daming Sun, Yingbing Lai, Wei Liu, Ying Zhong and Zhangyong Li
Biosensors 2023, 13(8), 791; https://doi.org/10.3390/bios13080791 - 4 Aug 2023
Cited by 3 | Viewed by 1779
Abstract
Prevailing methods for esophageal motility assessments, such as perfusion manometry and probe-based function imaging, frequently overlook the intricate stress fields acting on the liquid-filled balloons at the forefront of the probing device within the esophageal lumen. To bridge this knowledge gap, we innovatively [...] Read more.
Prevailing methods for esophageal motility assessments, such as perfusion manometry and probe-based function imaging, frequently overlook the intricate stress fields acting on the liquid-filled balloons at the forefront of the probing device within the esophageal lumen. To bridge this knowledge gap, we innovatively devised an infusible flexible balloon catheter, equipped with a quartet of PVDF piezoelectric sensors. This design, working in concert with a bespoke local key-node analytical algorithm and a sensor array state analysis model, seeks to shed new light on the dynamic mechanical characteristics at pivotal esophageal locales. To further this endeavor, we pioneered a singular closed balloon system and a complementary signal acquisition and processing system that employs a homogeneously distributed PVDF piezoelectric sensor array for the real-time monitoring of dynamic mechanical nuances in the esophageal segment. An advanced analytical model was established to scrutinize the coupled physical fields under varying degrees of balloon inflation, thereby facilitating a thorough dynamic stress examination of local esophageal nodes. Our rigorous execution of static, dynamic, and simulated swallowing experiments robustly substantiated the viability of our design, the logical coherence of our esophageal key-point stress analytical algorithm, and the potential clinical utility of a flexible esophageal key-node stress detection balloon probe outfitted with a PVDF array. This study offers a fresh lens through which esophageal motility testing can be viewed and improved upon. Full article
(This article belongs to the Special Issue Emerging Point-of-Care Biosensors and Their Applications)
Show Figures

Figure 1

12 pages, 4644 KiB  
Article
Comparative Evaluations on Real-Time Monitoring of Temperature Sensors during Endoscopic Laser Application
by Minh Duc Ta, Van Gia Truong, Seonghee Lim, Byeong-Il Lee and Hyun Wook Kang
Sensors 2023, 23(13), 6069; https://doi.org/10.3390/s23136069 - 30 Jun 2023
Cited by 5 | Viewed by 2038
Abstract
Temperature sensors, such as Fiber Bragg Grating (FBG) and thermocouple (TC), have been widely used for monitoring the interstitial tissue temperature during laser irradiation. The aim of the current study was to compare the performance of both FBG and TC in real-time temperature [...] Read more.
Temperature sensors, such as Fiber Bragg Grating (FBG) and thermocouple (TC), have been widely used for monitoring the interstitial tissue temperature during laser irradiation. The aim of the current study was to compare the performance of both FBG and TC in real-time temperature monitoring during endoscopic and circumferential laser treatment on tubular tissue structure. A 600-µm core-diameter diffusing applicator was employed to deliver 980-nm laser light (30 W for 90 s) circumferentially for quantitative evaluation. The tip of the TC was covered with a white tube (W-TC) in order to prevent direct light absorption and to minimize temperature overestimation. The temperature measurements in air demonstrated that the measurement difference in the temperature elevations was around 3.5 °C between FBG and W-TC. Ex vivo porcine liver tests confirmed that the measurement difference became lower (less than 1 °C). Ex vivo porcine esophageal tissue using a balloon-integrated catheter exhibited that both FBG and W-TC consistently showed a comparable trend of temperature measurements during laser irradiation (~2 °C). The current study demonstrated that the white tube-covered TC could be a feasible sensor to monitor interstitial tissue temperature with minimal overestimation during endoscopic laser irradiation. Further in vivo studies on gastroesophageal reflux disease will investigate the performance of the W-TC to monitor the temperature of the esophageal mucosa surface in real-time mode to warrant the safety of endoscopic laser treatment. Full article
Show Figures

Figure 1

11 pages, 1249 KiB  
Article
Assessment of Inspiratory Effort in Spontaneously Breathing COVID-19 ARDS Patients Undergoing Helmet CPAP: A Comparison between Esophageal, Transdiaphragmatic and Central Venous Pressure Swing
by Sergio Lassola, Sara Miori, Andrea Sanna, Ilaria Menegoni, Silvia De Rosa, Giacomo Bellani and Michele Umbrello
Diagnostics 2023, 13(11), 1965; https://doi.org/10.3390/diagnostics13111965 - 5 Jun 2023
Cited by 8 | Viewed by 2064
Abstract
Introduction: The clinical features of COVID-19 are highly variable. It has been speculated that the progression across COVID-19 may be triggered by excessive inspiratory drive activation. The aim of the present study was to assess whether the tidal swing in central venous pressure [...] Read more.
Introduction: The clinical features of COVID-19 are highly variable. It has been speculated that the progression across COVID-19 may be triggered by excessive inspiratory drive activation. The aim of the present study was to assess whether the tidal swing in central venous pressure (ΔCVP) is a reliable estimate of inspiratory effort. Methods: Thirty critically ill patients with COVID-19 ARDS underwent a PEEP trial (0–5–10 cmH2O) during helmet CPAP. Esophageal (ΔPes) and transdiaphragmatic (ΔPdi) pressure swings were measured as indices of inspiratory effort. ΔCVP was assessed via a standard venous catheter. A low and a high inspiratory effort were defined as ΔPes ≤ 10 and  >15 cmH2O, respectively. Results: During the PEEP trial, no significant changes in ΔPes (11 [6–16] vs. 11 [7–15] vs. 12 [8–16] cmH2O, p = 0.652) and in ΔCVP (12 [7–17] vs. 11.5 [7–16] vs. 11.5 [8–15] cmH2O, p = 0.918) were detected. ΔCVP was significantly associated with ΔPes (marginal R2 0.87, p < 0.001). ΔCVP recognized both low (AUC-ROC curve 0.89 [0.84–0.96]) and high inspiratory efforts (AUC-ROC curve 0.98 [0.96–1]). Conclusions: ΔCVP is an easily available a reliable surrogate of ΔPes and can detect a low or a high inspiratory effort. This study provides a useful bedside tool to monitor the inspiratory effort of spontaneously breathing COVID-19 patients. Full article
(This article belongs to the Section Medical Imaging and Theranostics)
Show Figures

Figure 1

8 pages, 2480 KiB  
Case Report
Piriform Fossa Injury during Calibration Tube Insertion in Laparoscopic Sleeve Gastrectomy
by Taiki Nabekura, Takashi Oshiro, Kotaro Wakamatsu, Natsumi Kitahara, Yuki Moriyama, Kengo Kadoya, Ayami Sato, Tomoaki Kitahara, Tasuku Urita, Yu Sato, Masaru Tsuchiya and Shinich Okazumi
J. Clin. Med. 2023, 12(11), 3824; https://doi.org/10.3390/jcm12113824 - 2 Jun 2023
Cited by 1 | Viewed by 1752
Abstract
Piriform fossa and/or esophageal injuries caused by calibration tubes are relatively rare and remain unelucidated. Herein, we report the case of a 36-year-old woman with morbid obesity, sleep apnea, and menstrual abnormalities who was scheduled to undergo laparoscopic sleeve gastrectomy (LSG). We inserted [...] Read more.
Piriform fossa and/or esophageal injuries caused by calibration tubes are relatively rare and remain unelucidated. Herein, we report the case of a 36-year-old woman with morbid obesity, sleep apnea, and menstrual abnormalities who was scheduled to undergo laparoscopic sleeve gastrectomy (LSG). We inserted a 36-Fr Nelaton catheter made of natural rubber as a calibration tube during the surgery. However, excessive resistance was observed. We confirmed a submucosal layer detachment approximately 5 cm from the left piriform fossa to the esophagus using intraoperative endoscopy. Additionally, LSG was performed using an endoscope as the guiding calibration tube. We inserted a nasogastric tube under endoscopy with a guidewire before completing the surgery, hoping for a guiding effect on the saliva flow. After 17 months, the patient had successfully lost weight postoperatively without complaints of neck pain or discomfort during swallowing. Therefore, in cases where the damage is limited to the submucosal layer, as in this case, conservative therapy should be considered; this is similar to the concept of endoscopic submucosal dissection not requiring suture closure. This case highlights the risk of iatrogenic injuries to the piriform fossa and/or esophagus during LSG and the importance of careful calibration tube insertion to prevent them. Full article
(This article belongs to the Section General Surgery)
Show Figures

Figure 1

16 pages, 1798 KiB  
Review
Diagnosis of Laryngopharyngeal Reflux: Past, Present, and Future—A Mini-Review
by Han-Chung Lien, Ping-Huan Lee and Chen-Chi Wang
Diagnostics 2023, 13(9), 1643; https://doi.org/10.3390/diagnostics13091643 - 7 May 2023
Cited by 14 | Viewed by 6402
Abstract
Laryngopharyngeal reflux (LPR) is a variant of gastroesophageal reflux disease (GERD) in which gastric refluxate irritates the lining of the aerodigestive tract and causes troublesome airway symptoms or complications. LPR is a prevalent disease that creates a significant socioeconomic burden due to its [...] Read more.
Laryngopharyngeal reflux (LPR) is a variant of gastroesophageal reflux disease (GERD) in which gastric refluxate irritates the lining of the aerodigestive tract and causes troublesome airway symptoms or complications. LPR is a prevalent disease that creates a significant socioeconomic burden due to its negative impact on quality of life, tremendous medical expense, and possible cancer risk. Although treatment modalities are similar between LPR and GERD, the diagnosis of LPR is more challenging than GERD due to its non-specific symptoms/signs. Due to the lack of pathognomonic features of endoscopy, mounting evidence focused on physiological diagnostic testing. Two decades ago, a dual pH probe was considered the gold standard for detecting pharyngeal acidic reflux episodes. Despite an association with LPR, the dual pH was unable to predict the treatment response in clinical practice, presumably due to frequently encountered artifacts. Currently, hypopharygneal multichannel intraluminal impedance-pH catheters incorporating two trans-upper esophageal sphincter impedance sensors enable to differentiate pharyngeal refluxes from swallows. The validation of pharyngeal acid reflux episodes that are relevant to anti-reflux treatment is, therefore, crucial. Given no diagnostic gold standard of LPR, this review article aimed to discuss the evolution of objective diagnostic testing and its predictive role of treatment response. Full article
Show Figures

Figure 1

14 pages, 2008 KiB  
Review
Respiratory Variations of Central Venous Pressure as Indices of Pleural Pressure Swings: A Narrative Review
by Michele Umbrello, Sergio Cereghini and Stefano Muttini
Diagnostics 2023, 13(6), 1022; https://doi.org/10.3390/diagnostics13061022 - 7 Mar 2023
Cited by 8 | Viewed by 3371
Abstract
The measurement of pleural (or intrathoracic) pressure is a key element for a proper setting of mechanical ventilator assistance as both under- and over-assistance may cause detrimental effects on both the lungs and the diaphragm. Esophageal pressure (Pes) is the gold standard tool [...] Read more.
The measurement of pleural (or intrathoracic) pressure is a key element for a proper setting of mechanical ventilator assistance as both under- and over-assistance may cause detrimental effects on both the lungs and the diaphragm. Esophageal pressure (Pes) is the gold standard tool for such measurements; however, it is invasive and seldom used in daily practice, and easier, bedside-available tools that allow for rapid and continuous monitoring are greatly needed. The tidal swing of central venous pressure (CVP) has long been proposed as a surrogate for pleural pressure (Ppl); however, despite the wide availability of central venous catheters, this variable is very often overlooked in critically ill patients. In the present narrative review, the physiological basis for the use of CVP waveforms to estimate Ppl is presented; the findings of previous and recent papers that addressed this topic are systematically reviewed, and the studies are divided into those reporting positive findings (i.e., CVP was found to be a reliable estimate of Pes or Ppl) and those reporting negative findings. Both the strength and pitfalls of this approach are highlighted, and the current knowledge gaps and direction for future research are delineated. Full article
(This article belongs to the Special Issue What’s New in Acute Respiratory Distress Syndrome)
Show Figures

Figure 1

4 pages, 796 KiB  
Case Report
An Assessment of Carotid Flow Time Using a Portable Handheld Ultrasound Device: The Ideal Tool for Guiding Intraoperative Fluid Management?
by Lauren E. Gibson, James E. Mitchell, Edward A. Bittner and Marvin G. Chang
Micromachines 2023, 14(3), 510; https://doi.org/10.3390/mi14030510 - 22 Feb 2023
Cited by 5 | Viewed by 2691
Abstract
Volume resuscitation is a cornerstone of modern anesthesia care. Finding the right balance to avoid inadequate or excess volume administration is often difficult to clinically discern and can lead to negative consequences. Pulse pressure variation is often intraoperatively used to guide volume resuscitation; [...] Read more.
Volume resuscitation is a cornerstone of modern anesthesia care. Finding the right balance to avoid inadequate or excess volume administration is often difficult to clinically discern and can lead to negative consequences. Pulse pressure variation is often intraoperatively used to guide volume resuscitation; however, this requires an invasive arterial line and is generally only applicable to patients who are mechanically ventilated. Unfortunately, without a pulmonary artery catheter or another costly noninvasive device, performing serial measurements of cardiac output is challenging, time-consuming, and often impractical. Furthermore, noninvasive measures such as LVOT VTI require significant technical expertise as well as access to the chest, which may not be practical during and after surgery. Other noninvasive techniques such as bioreactance and esophageal Doppler require the use of costly single-use sensors. Here, we present a case report on the use of corrected carotid flow time (ccFT) from a portable, handheld ultrasound device as a practical, noninvasive, and technically straightforward method to assess fluid responsiveness in the perioperative period, as well as the inpatient and outpatient settings. Full article
(This article belongs to the Special Issue Point-of-Care Diagnostic Devices)
Show Figures

Figure 1

10 pages, 635 KiB  
Article
Esophageal Protection and Temperature Monitoring Using the Circa S-Cath™ Temperature Probe during Epicardial Radiofrequency Ablation of the Pulmonary Veins and Posterior Left Atrium
by Rani Kronenberger, Orlando Parise, Ines Van Loo, Sandro Gelsomino, Ashley Welch, Carlo De Asmundis and Mark La Meir
J. Clin. Med. 2022, 11(23), 6939; https://doi.org/10.3390/jcm11236939 - 25 Nov 2022
Cited by 2 | Viewed by 2056
Abstract
Although epicardial bipolar radiofrequency ablation should diminish the risk of esophageal thermal injury in comparison to an endocardial ablation, cases of lethal atrio-esophageal fistula have been reported. To better understand this risk and to reduce the possibility of a thermal injury, we monitored [...] Read more.
Although epicardial bipolar radiofrequency ablation should diminish the risk of esophageal thermal injury in comparison to an endocardial ablation, cases of lethal atrio-esophageal fistula have been reported. To better understand this risk and to reduce the possibility of a thermal injury, we monitored the esophageal temperature with the Circa S-Cath™ temperature probe during and immediately after the ablation while implementing three procedural safety measures. Twenty patients (15 males; 63 ± 10 years) were prospectively enrolled (November 2019–February 2021). All patients underwent an epicardial ablation procedure, including an antral left and right pulmonary vein isolation with bidirectional bipolar clamping, and a roof and inferior line using unidirectional bipolar radiofrequency. Three procedural preventive mitigations were implemented: (1) transesophageal echocardiographic visualization of the atrio-esophageal interface, with probe retraction before the energy delivery; (2) lifting the ablated tissue away from the esophagus during an energy application; and (3) a 30 s cool-off and irrigation period after the energy delivery. The esophageal temperature was recorded using an insulated multisensory intraluminal esophageal temperature probe (Circa S-Cath™). Of the 20 patients enrolled, 7 patients had paroxysmal atrial fibrillation (AF), 8 persistent AF and 5 longstanding persistent AF. The average maximum luminal esophageal temperature observed was 36.2 ± 0.7 °C (34.8–38.2 °C). In our clinical experience, no abrupt increase in the luminal esophageal temperature above the baseline was observed. Since no measurements exceeded the threshold of 39 °C, no prompt interruption of energy delivery was required. Intraluminal esophageal temperature monitoring is feasible and can be helpful in confirming correct catheter position and safe energy application in bipolar epicardial left atrial ablation. Intra-procedural preventive mitigations should be implemented to reduce the risk of esophageal temperature rises. Full article
(This article belongs to the Special Issue State of the Art in Management of Atrial Fibrillation)
Show Figures

Figure 1

Back to TopTop