20 pages, 3517 KB  
Review
Review of Cardiovascular Mock Circulatory Loop Designs and Applications
by Victor K. Tsui and Daniel Ewert
Bioengineering 2025, 12(8), 851; https://doi.org/10.3390/bioengineering12080851 - 7 Aug 2025
Viewed by 2012
Abstract
Cardiovascular diseases remain a leading cause of mortality in the United States, driving the need for advanced cardiovascular devices and pharmaceuticals. Mock Circulatory Loops (MCLs) have emerged as essential tools for in vitro testing, replicating pulsatile pressure and flow to simulate various physiological [...] Read more.
Cardiovascular diseases remain a leading cause of mortality in the United States, driving the need for advanced cardiovascular devices and pharmaceuticals. Mock Circulatory Loops (MCLs) have emerged as essential tools for in vitro testing, replicating pulsatile pressure and flow to simulate various physiological and pathological conditions. While many studies focus on custom MCL designs tailored to specific applications, few have systematically reviewed their use in device testing, and none have assessed their broader utility across diverse biomedical domains. This comprehensive review categorizes MCL designs into three types: mechanical, computational, and hybrid. Applications are classified into four major areas: Cardiovascular Devices Testing, Clinical Training and Education, Hemodynamics and Blood Flow Studies, and Disease Modeling. Most existing MCLs are complex, highly specialized, and difficult to reproduce, highlighting the need for simplified, standardized, and programmable hybrid systems. Improved validation and waveform fidelity—particularly through incorporation of the dicrotic notch and other waveform parameters—are critical for advancing MCL reliability. Furthermore, integration of machine learning and artificial intelligence holds significant promise for enhancing waveform analysis, diagnostics, predictive modeling, and personalized care. In conclusion, the development of MCLs should prioritize standardization, simplification, and broader accessibility to expand their impact across biomedical research and clinical translation. Full article
(This article belongs to the Special Issue Cardiovascular Models and Biomechanics)
Show Figures

Figure 1

18 pages, 5112 KB  
Article
The Phthalic Selenoanhydride Decreases Rat Blood Pressure and Tension of Isolated Mesenteric, Femoral and Renal Arteries
by Peter Balis, Andrea Berenyiova, Anton Misak, Marian Grman, Zuzana Rostakova, Iveta Waczulikova, Sona Cacanyiova, Enrique Domínguez-Álvarez and Karol Ondrias
Molecules 2023, 28(12), 4826; https://doi.org/10.3390/molecules28124826 - 17 Jun 2023
Cited by 6 | Viewed by 1989
Abstract
Phthalic selenoanhydride (R-Se) solved in physiological buffer releases various reactive selenium species including H2Se. It is a potential compound for Se supplementation which exerts several biological effects, but its effect on the cardiovascular system is still unknown. Therefore, herein we aimed [...] Read more.
Phthalic selenoanhydride (R-Se) solved in physiological buffer releases various reactive selenium species including H2Se. It is a potential compound for Se supplementation which exerts several biological effects, but its effect on the cardiovascular system is still unknown. Therefore, herein we aimed to study how R-Se affects rat hemodynamic parameters and vasoactive properties in isolated arteries. The right jugular vein of anesthetized Wistar male rats was cannulated for IV administration of R-Se. The arterial pulse waveform (APW) was detected by cannulation of the left carotid artery, enabling the evaluation of 35 parameters. R-Se (1–2 µmol kg−1), but not phthalic anhydride or phthalic thioanhydride, transiently modulated most of the APW parameters including a decrease in systolic and diastolic blood pressure, heart rate, dP/dtmax relative level, or anacrotic/dicrotic notches, whereas systolic area, dP/dtmin delay, dP/dtd delay, anacrotic notch relative level or its delay increased. R-Se (~10–100 µmol L−1) significantly decreased the tension of precontracted mesenteric, femoral, and renal arteries, whereas it showed a moderate vasorelaxation effect on thoracic aorta isolated from normotensive Wistar rats. The results imply that R-Se acts on vascular smooth muscle cells, which might underlie the effects of R-Se on the rat hemodynamic parameters. Full article
(This article belongs to the Special Issue Bioorganic Chemistry: Current and Future Perspectives)
Show Figures

Graphical abstract

18 pages, 6202 KB  
Article
Photoplethysmography Signal Wavelet Enhancement and Novel Features Selection for Non-Invasive Cuff-Less Blood Pressure Monitoring
by Filippo Attivissimo, Luisa De Palma, Attilio Di Nisio, Marco Scarpetta and Anna Maria Lucia Lanzolla
Sensors 2023, 23(4), 2321; https://doi.org/10.3390/s23042321 - 19 Feb 2023
Cited by 25 | Viewed by 4671
Abstract
In this paper, new features relevant to blood pressure (BP) estimation using photoplethysmography (PPG) are presented. A total of 195 features, including the proposed ones and those already known in the literature, have been calculated on a set composed of 50,000 pulses from [...] Read more.
In this paper, new features relevant to blood pressure (BP) estimation using photoplethysmography (PPG) are presented. A total of 195 features, including the proposed ones and those already known in the literature, have been calculated on a set composed of 50,000 pulses from 1080 different patients. Three feature selection methods, namely Correlation-based Feature Selection (CFS), RReliefF and Minimum Redundancy Maximum Relevance (MRMR), have then been applied to identify the most significant features for BP estimation. Some of these features have been extracted through a novel PPG signal enhancement method based on the use of the Maximal Overlap Discrete Wavelet Transform (MODWT). As a matter of fact, the enhanced signal leads to a reliable identification of the characteristic points of the PPG signal (e.g., systolic, diastolic and dicrotic notch points) by simple means, obtaining results comparable with those from purposely defined algorithms. For systolic points, mean and std of errors computed as the difference between the locations obtained using a purposely defined already known algorithm and those using the MODWT enhancement are, respectively, 0.0097 s and 0.0202 s; for diastolic points they are, respectively, 0.0441 s and 0.0486 s; for dicrotic notch points they are 0.0458 s and 0.0896 s. Hence, this study leads to the selection of several new features from the MODWT enhanced signal on every single pulse extracted from PPG signals, in addition to features already known in the literature. These features can be employed to train machine learning (ML) models useful for estimating systolic blood pressure (SBP) and diastolic blood pressure (DBP) in a non-invasive way, which is suitable for telemedicine health-care monitoring. Full article
(This article belongs to the Special Issue Feature Papers in Physical Sensors 2022)
Show Figures

Figure 1

15 pages, 1550 KB  
Article
Noninvasive Monitoring of Simulated Hemorrhage and Whole Blood Resuscitation
by Jay F. Gupta, Saaid H. Arshad, Brian A. Telfer, Eric J. Snider and Victor A. Convertino
Biosensors 2022, 12(12), 1168; https://doi.org/10.3390/bios12121168 - 14 Dec 2022
Cited by 10 | Viewed by 3977
Abstract
Hemorrhage is the leading cause of preventable death from trauma. Accurate monitoring of hemorrhage and resuscitation can significantly reduce mortality and morbidity but remains a challenge due to the low sensitivity of traditional vital signs in detecting blood loss and possible hemorrhagic shock. [...] Read more.
Hemorrhage is the leading cause of preventable death from trauma. Accurate monitoring of hemorrhage and resuscitation can significantly reduce mortality and morbidity but remains a challenge due to the low sensitivity of traditional vital signs in detecting blood loss and possible hemorrhagic shock. Vital signs are not reliable early indicators because of physiological mechanisms that compensate for blood loss and thus do not provide an accurate assessment of volume status. As an alternative, machine learning (ML) algorithms that operate on an arterial blood pressure (ABP) waveform have been shown to provide an effective early indicator. However, these ML approaches lack physiological interpretability. In this paper, we evaluate and compare the performance of ML models trained on nine ABP-derived features that provide physiological insight, using a database of 13 human subjects from a lower-body negative pressure (LBNP) model of progressive central hypovolemia and subsequent progressive restoration to normovolemia (i.e., simulated hemorrhage and whole blood resuscitation). Data were acquired at multiple repressurization rates for each subject to simulate varying resuscitation rates, resulting in 52 total LBNP collections. This work is the first to use a single ABP-based algorithm to monitor both simulated hemorrhage and resuscitation. A gradient-boosted regression tree model trained on only the half-rise to dicrotic notch (HRDN) feature achieved a root-mean-square error (RMSE) of 13%, an R2 of 0.82, and area under the receiver operating characteristic curve of 0.97 for detecting decompensation. This single-feature model’s performance compares favorably to previously reported results from more-complex black box machine learning models. This model further provides physiological insight because HRDN represents an approximate measure of the delay between the ABP ejected and reflected wave and therefore is an indication of cardiac and peripheral vascular mechanisms that contribute to the compensatory response to blood loss and replacement. Full article
Show Figures

Figure 1

9 pages, 1643 KB  
Article
Novel Method to Detect Pitfalls of Intracoronary Pressure Measurements by Pressure Waveform Analysis
by Csaba Jenei, Balázs Tar, András Ágoston, Péter Sánta, János Sánta, Benjámin Csippa, Richárd Wéber, Dániel Gyürki, Gábor Halász, Gábor Tamás Szabó, Dániel Czuriga and Zsolt Kőszegi
J. Pers. Med. 2022, 12(12), 2035; https://doi.org/10.3390/jpm12122035 - 8 Dec 2022
Cited by 2 | Viewed by 1832
Abstract
Potential pitfalls of fractional flow reserve (FFR) measurements are well-known drawbacks of invasive physiology measurement, e.g., significant drift of the distal pressure trace may lead to the misclassification of stenoses. Thus, a simultaneous waveform analysis of the pressure traces may be of help [...] Read more.
Potential pitfalls of fractional flow reserve (FFR) measurements are well-known drawbacks of invasive physiology measurement, e.g., significant drift of the distal pressure trace may lead to the misclassification of stenoses. Thus, a simultaneous waveform analysis of the pressure traces may be of help in the quality control of these measurements by online detection of such artefacts as the drift or the wedging of the catheter. In the current study, we analysed the intracoronary pressure waveform with a dedicated program. In 130 patients, 232 FFR measurements were performed and derivative pressure curves were calculated. Local amplitude around the dicrotic notch was calculated from the distal intracoronary pressure traces (δdPn/dt). A unidimensional arterial network model of blood flow was employed to simulate the intracoronary pressure traces at different flow rates. There was a strong correlation between δdPn/dt values measured during hyperaemia and FFR (r = 0.88). Diagnostic performance of distal δdPn/dt ≤ 3.52 for the prediction of FFR ≤ 0.80 was 91%. The correlation between the pressure gradient and the corresponding δdPn/dt values obtained from all measurements independently of the physiological phase was also significant (r = 0.80). During simulation, the effect of flow rate on δdPn/dt further supported the close correlation between the pressure ratios and δdPn/dt. Discordance between the FFR and the δdPn/dt can be used as an indicator of possible technical problems of FFR measurements. Hence, an online calculation of the δdPn/dt may be helpful in avoiding some pitfalls of FFR evaluation. Full article
(This article belongs to the Section Personalized Therapy in Clinical Medicine)
Show Figures

Graphical abstract

18 pages, 4220 KB  
Article
A Flexible Near-Field Biosensor for Multisite Arterial Blood Flow Detection
by Noor Mohammed, Kim Cluff, Mark Sutton, Bernardo Villafana-Ibarra, Benjamin E. Loflin, Jacob L. Griffith, Ryan Becker, Subash Bhandari, Fayez Alruwaili and Jaydip Desai
Sensors 2022, 22(21), 8389; https://doi.org/10.3390/s22218389 - 1 Nov 2022
Cited by 11 | Viewed by 5392
Abstract
Modern wearable devices show promising results in terms of detecting vital bodily signs from the wrist. However, there remains a considerable need for a device that can conform to the human body’s variable geometry to accurately detect those vital signs and to understand [...] Read more.
Modern wearable devices show promising results in terms of detecting vital bodily signs from the wrist. However, there remains a considerable need for a device that can conform to the human body’s variable geometry to accurately detect those vital signs and to understand health better. Flexible radio frequency (RF) resonators are well poised to address this need by providing conformable bio-interfaces suitable for different anatomical locations. In this work, we develop a compact wearable RF biosensor that detects multisite hemodynamic events due to pulsatile blood flow through noninvasive tissue–electromagnetic (EM) field interaction. The sensor consists of a skin patch spiral resonator and a wearable transceiver. During resonance, the resonator establishes a strong capacitive coupling with layered dielectric tissues due to impedance matching. Therefore, any variation in the dielectric properties within the near-field of the coupled system will result in field perturbation. This perturbation also results in RF carrier modulation, transduced via a demodulator in the transceiver unit. The main elements of the transceiver consist of a direct digital synthesizer for RF carrier generation and a demodulator unit comprised of a resistive bridge coupled with an envelope detector, a filter, and an amplifier. In this work, we build and study the sensor at the radial artery, thorax, carotid artery, and supraorbital locations of a healthy human subject, which hold clinical significance in evaluating cardiovascular health. The carrier frequency is tuned at the resonance of the spiral resonator, which is 34.5 ± 1.5 MHz. The resulting transient waveforms from the demodulator indicate the presence of hemodynamic events, i.e., systolic upstroke, systolic peak, dicrotic notch, and diastolic downstroke. The preliminary results also confirm the sensor’s ability to detect multisite blood flow events noninvasively on a single wearable platform. Full article
(This article belongs to the Special Issue Wearable and Unobtrusive Technologies for Healthcare Monitoring)
Show Figures

Figure 1

10 pages, 904 KB  
Article
Hemodynamic Monitoring by Smartphone—Preliminary Report from a Comparative Prospective Observational Study
by Michał P. Pluta, Magdalena Dziech, Mateusz N. Zachura, Anna J. Szczepańska, Piotr F. Czempik, Piotr S. Liberski and Łukasz J. Krzych
J. Pers. Med. 2022, 12(2), 200; https://doi.org/10.3390/jpm12020200 - 1 Feb 2022
Cited by 3 | Viewed by 2550
Abstract
Background: Advanced hemodynamic monitoring supports making therapeutic decisions in critically ill patients. New technologies, including mobile health, have been introduced into the hemodynamic monitoring armamentarium. However, each monitoring method has potential limitations—content, technical and organizational. The aim of this study was to assess [...] Read more.
Background: Advanced hemodynamic monitoring supports making therapeutic decisions in critically ill patients. New technologies, including mobile health, have been introduced into the hemodynamic monitoring armamentarium. However, each monitoring method has potential limitations—content, technical and organizational. The aim of this study was to assess the comparability between measurements obtained with two arterial pressure cardiac output methods: Capstesia™ smartphone hemodynamic software (CS) and LiDCO Rapid™ uncalibrated hemodynamic monitor (LR). Methods: The initial analysis included 16 patients in the period 06–09 2020 without limitations that could make the results obtained unreliable. Eighty pairs of cardiac output measurements were obtained. The comparability of cardiac output results obtained with both methods was assessed using the Spearman’s rank correlation coefficient (R), the intra-class correlation (CCC) and the Bland–Altman curves analysis (B-A). Results: The median (IQR) cardiac output measured with CS and LR were 4.6 (3.9–5.7) and 5.5 (4.6–7.4) L min−1, respectively. In the B-A analysis, CS cardiac output values were on average 1.2 (95% CI −2.1–4.4) L min-1 lower than LR values. The correlation between cardiac output with CS and LR was moderate (r = 0.5; p = 0.04). After adjusting for the presence of the dicrotic notch on the pulse waveform, in the group of eight patients with a visible dicrotic notch, the CS and LR results differed by only 0.1 (95% CI −0.8–1.1) L min−1, the correlation between CS and LR was close to complete (r = 0.96; p < 0.001), and the percentage error was 40%, with a CCC-CS of 0.98 (95% CI 0.95–0.99). Conclusions: The CapstesiaTM smartphone software can provide an alternative method of cardiac output assessment in patients meeting arterial pressure cardiac output evaluation criteria with a clearly discernible dicrotic notch on the arterial pulse pressure waveform. It is necessary to confirm the obtained observations on a larger group of patients; however, it may potentially make objective hemodynamic measurements ubiquitous in patients with invasive arterial pressure monitoring with a clearly discernible dicrotic notch. Full article
(This article belongs to the Special Issue Postoperative Complications and Personalized Medicine)
Show Figures

Figure 1

14 pages, 768 KB  
Article
Discussion of Cuffless Blood Pressure Prediction Using Plethysmograph Based on a Longitudinal Experiment: Is the Individual Model Necessary?
by Koshiro Kido, Zheng Chen, Ming Huang, Toshiyo Tamura, Wei Chen, Naoaki Ono, Masachika Takeuchi, Md. Altaf-Ul-Amin and Shigehiko Kanaya
Life 2022, 12(1), 11; https://doi.org/10.3390/life12010011 - 22 Dec 2021
Cited by 8 | Viewed by 3257
Abstract
Using the Plethysmograph (PPG) signal to estimate blood pressure (BP) is attractive given the convenience and possibility of continuous measurement. However, due to the personal differences and the insufficiency of data, the dilemma between the accuracy for a small dataset and the robustness [...] Read more.
Using the Plethysmograph (PPG) signal to estimate blood pressure (BP) is attractive given the convenience and possibility of continuous measurement. However, due to the personal differences and the insufficiency of data, the dilemma between the accuracy for a small dataset and the robustness as a general method remains. To this end, we scrutinized the whole pipeline from the feature selection to regression model construction based on a one-month experiment with 11 subjects. By constructing the explanatory features consisting of five general PPG waveform features that do not require the identification of dicrotic notch and diastolic peak and the heart rate, three regression models, which are partial least square, local weighted partial least square, and Gaussian Process model, were built to reflect the underlying assumption about the nature of the fitting problem. By comparing the regression models, it can be confirmed that an individual Gaussian Process model attains the best results with 5.1 mmHg and 4.6 mmHg mean absolute error for SBP and DBP and 6.2 mmHg and 5.4 mmHg standard deviation for SBP and DBP. Moreover, the results of the individual models are significantly better than the generalized model built with the data of all subjects. Full article
(This article belongs to the Special Issue Recent Trends in Computational Research on Diseases)
Show Figures

Figure 1

19 pages, 6209 KB  
Article
Characterization of Rat Cardiovascular System by Anacrotic/Dicrotic Notches in the Condition of Increase/Decrease of NO Bioavailability
by Lenka Tomasova, Anton Misak, Lucia Kurakova, Marian Grman and Karol Ondrias
Int. J. Mol. Sci. 2020, 21(18), 6685; https://doi.org/10.3390/ijms21186685 - 12 Sep 2020
Cited by 4 | Viewed by 3029
Abstract
We characterized modes of action of NO-donor S-nitrosoglutathione (GSNO) and NO-synthase inhibitor l-NAME derived from dicrotic (DiN) and anacrotic (AnN) notches of rat arterial pulse waveform (APW) in the condition of increased/decreased NO bioavailability. The cross-relationship patterns of DiN and AnN with [...] Read more.
We characterized modes of action of NO-donor S-nitrosoglutathione (GSNO) and NO-synthase inhibitor l-NAME derived from dicrotic (DiN) and anacrotic (AnN) notches of rat arterial pulse waveform (APW) in the condition of increased/decreased NO bioavailability. The cross-relationship patterns of DiN and AnN with 34 hemodynamic parameters (HPs) induced by GSNO and l-NAME are presented. After GSNO bolus administration, approximate non-hysteresis relationships were observed in the difference between DiN–AnN (mmHg) blood pressure (BP) and other 19 HPs, suggesting that these HPs, i.e., their signaling pathways, responding to NO concentration, are directly connected. Hysteresis relationships were observed between DiN-AnN (mmHg) and other 14 HPs, suggesting that signaling pathways of these HPs are indirectly connected. The hysteresis relationships were only observed between the time interval DiN-AnN (ms) and other 34 HPs, indicating no direct connection of signaling pathways. The cross-relationship patterns of DiN-AnN (mmHg), but not DiN-AnN (ms), induced by l-NAME were in accordance to the increased NO bioavailability induced by GSNO. In conclusion, we found the non-hysteresis/hysteresis cross-relationship “patterns” of DiN-AnN intervals to other HPs in the presence of GSNO that revealed their direct or indirect signaling pathways connections. This may contribute to our understanding of biological effects of natural substances that modulate NO production and/or NO signaling pathways. Full article
Show Figures

Figure 1

12 pages, 3175 KB  
Article
Non-Invasive Device for Blood Pressure Wave Acquisition by Means of Mechanical Transducer
by David Zambrana-Vinaroz, Jose Maria Vicente-Samper, Carlos G. Juan, Vicente Esteve-Sala and Jose Maria Sabater-Navarro
Sensors 2019, 19(19), 4311; https://doi.org/10.3390/s19194311 - 5 Oct 2019
Cited by 11 | Viewed by 6145
Abstract
Blood pressure wave monitoring provides interesting information about the patient’s cardiovascular function. For this reason, this article proposes a non-invasive device capable of capturing the vibrations (pressure waves) produced by the carotid artery by means of a pressure sensor encapsulated in a closed [...] Read more.
Blood pressure wave monitoring provides interesting information about the patient’s cardiovascular function. For this reason, this article proposes a non-invasive device capable of capturing the vibrations (pressure waves) produced by the carotid artery by means of a pressure sensor encapsulated in a closed dome filled with air. When the device is placed onto the outer skin of the carotid area, the vibrations of the artery will exert a deformation in the dome, which, in turn, will lead to a pressure increase in its inner air. Then, the sensor inside the dome captures this pressure increase. By combining the blood pressure wave obtained with this device together with the ECG signal, it is possible to help the screening of the cardiovascular system, obtaining parameters such as heart rate variability (HRV) and pulse transit time (PTT). The results show how the pressure wave has been successfully obtained in the carotid artery area, discerning the characteristic points of this signal. The features of this device compare well with previous works by other authors. The main advantages of the proposed device are the reduced size, the cuffless condition, and the potential to be a continuous ambulatory device. These features could be exploited in ambulatory tests. Full article
(This article belongs to the Special Issue Mechanical Sensors)
Show Figures

Figure 1

27 pages, 30652 KB  
Article
Near-Wall Flow in Cerebral Aneurysms
by Vahid Goodarzi Ardakani, Xin Tu, Alberto M. Gambaruto, Iolanda Velho, Jorge Tiago, Adélia Sequeira and Ricardo Pereira
Fluids 2019, 4(2), 89; https://doi.org/10.3390/fluids4020089 - 16 May 2019
Cited by 17 | Viewed by 6234
Abstract
The region where the vascular lumen meets the surrounding endothelium cell layer, hence the interface region between haemodynamics and cell tissue, is of primary importance in the physiological functions of the cardiovascular system. The functions include mass transport to/from the blood and tissue, [...] Read more.
The region where the vascular lumen meets the surrounding endothelium cell layer, hence the interface region between haemodynamics and cell tissue, is of primary importance in the physiological functions of the cardiovascular system. The functions include mass transport to/from the blood and tissue, and signalling via mechanotransduction, which are primary functions of the cardiovascular system and abnormalities in these functions are known to affect disease formation and vascular remodelling. This region is denoted by the near-wall region in the present work, and we outline simple yet effective numerical recipes to analyse the near-wall flow field. Computational haemodynamics solutions are presented for six patient specific cerebral aneurysms, at three instances in the cardiac cycle: peak systole, end systole (taken as dicrotic notch) and end diastole. A sensitivity study, based on Newtonian and non-Newtonian rheological models, and different flow rate profiles, is effected for a selection of aneurysm cases. The near-wall flow field is described by the wall shear stress (WSS) and the divergence of wall shear stress (WSSdiv), as descriptors of tangential and normal velocity components, respectively, as well as the wall shear stress critical points. Relations between near-wall and free-stream flow fields are discussed. Full article
(This article belongs to the Special Issue Cardiovascular Flows)
Show Figures