Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (19)

Search Parameters:
Keywords = demanded 15 min peak power

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
38 pages, 11873 KB  
Article
Joint Forecasting of Daily Energy and Peak Demand for Bimodal Industrial Loads: A Metering-Only Two-Stage Framework
by Doyeon Ryu and Wonjae Yoo
Appl. Sci. 2026, 16(16), 8270; https://doi.org/10.3390/app16168270 - 19 Aug 2026
Viewed by 130
Abstract
Industrial tariffs and demand-response (DR) programs pay for two quantities—daily energy and daily peak demand—yet short-term forecasting research addresses mostly the first, and rarely under the constraints of small industrial sites: strongly bimodal operation and only one to two years of records. We [...] Read more.
Industrial tariffs and demand-response (DR) programs pay for two quantities—daily energy and daily peak demand—yet short-term forecasting research addresses mostly the first, and rarely under the constraints of small industrial sites: strongly bimodal operation and only one to two years of records. We propose the Two-Stage Adaptive Framework (TSAF), a metering-only method that detects bimodality, classifies each day as active or inactive from its partial-day consumption, and fits a regression model to active days only; the same 21 features serve both targets. On 15 min data from ten plating factories of the Ansan Plating Industrial Complex (19 months), TSAF reaches 16.2% mean MAPE on daily energy against 58.7% for a day-ahead reference, and no deep-learning model beats the 22-parameter Ridge regressor. On daily peak, evaluated on active days, a joint multi-factory Transformer reaches 8.4% MAPE against a 14.0% constant-predictor floor, and a training-free tabular foundation model (TabPFN) reaches a comparable 7.0% without cross-factory data; intraday peak timing (≈2 h mean error) marks the limit of the meter-only design. External validation on 36 stratified UCI clients delimits the framework’s scope, and a weather ablation, specified in advance of estimation, finds no significant gain (p = 0.23). After adjusting for Stage 1 misclassification and intraday dispatch feasibility, the ten factories gain about 60 million KRW (US$46,000) per year and avoid 15.4 tCO2 under Korean market conditions. Because TSAF needs only the smart-meter feed, power suppliers and DR aggregators can deploy it without access to customer-facility internals. Full article
Show Figures

Figure 1

39 pages, 1441 KB  
Article
A Replicable Asset-Light Demand-Side Management Protocol for Contracted-Capacity and Peak-Demand Risk Assessment in Existing Multi-Story Residential Buildings
by Po Chuan Huang, Szu-Wei Fang, Wei Lin and Shwu-Ting Lee
Sustainability 2026, 18(16), 8441; https://doi.org/10.3390/su18168441 - 18 Aug 2026
Viewed by 353
Abstract
Existing residential buildings require peak-demand governance even when complete sub-metering and advanced control systems are unavailable. This study develops a replicable asset-light demand-side management (DSM) protocol for contracted-capacity risk assessment. The protocol integrates utility-billing records, 15 min community main-meter (MP) and selected sub-meter [...] Read more.
Existing residential buildings require peak-demand governance even when complete sub-metering and advanced control systems are unavailable. This study develops a replicable asset-light demand-side management (DSM) protocol for contracted-capacity risk assessment. The protocol integrates utility-billing records, 15 min community main-meter (MP) and selected sub-meter data, operational-period segmentation, residual-load treatment, capacity-risk indicators, rule selection, event decomposition, and post-calibration verification. The protocol was examined in a Taiwanese condominium using utility records beginning in June 2022 and stabilized digital-meter data from April 2023 to May 2026. Four sub-metered systems explained 76.3% of monthly MP electricity use, with 23.7% retained as residual load. Under a 40 kW operational reference boundary, maximum MP demand reached 41.12 kW, yielding a utilization ratio of 1.028 and a relative capacity buffer of −2.8%. In a representative critical interval, the aggregate mechanical-power boundary contributed 79.6% of MP demand; however, equipment-level EV output was not independently recorded. After rule-based calibration, maximum MP demand was 29.36 kW, and no MP threshold-exceedance intervals or billing-level over-capacity surcharges were documented. These findings provide observational performance evidence rather than definitive causal proof. The contribution is a recalibratable diagnostic sequence for capacity-risk governance under partial metering and property-management constraints. Full article
Show Figures

Figure 1

16 pages, 5979 KB  
Article
Mixing and Aeration Effects in Outdoor Dual-Chamber Microbial Fuel Cells with Agarose Salt Bridges
by Mohamad K. Khawaja, Nour Alnajjar and Ammar Alkhalidi
Membranes 2026, 16(8), 275; https://doi.org/10.3390/membranes16080275 - 18 Aug 2026
Viewed by 191
Abstract
Microbial fuel cells (MFCs) provide a membrane-based bioelectrochemical route for simultaneous wastewater treatment and electricity generation. This study investigates the effect of aeration and mixing on the performance of dual-chamber microbial fuel cells (DCMFCs) operated outdoors using sugar-mix substrates. Five DCMFC configurations were [...] Read more.
Microbial fuel cells (MFCs) provide a membrane-based bioelectrochemical route for simultaneous wastewater treatment and electricity generation. This study investigates the effect of aeration and mixing on the performance of dual-chamber microbial fuel cells (DCMFCs) operated outdoors using sugar-mix substrates. Five DCMFC configurations were evaluated over 40 days, including baseline operation and individual or combined aeration and mixing strategies. Voltage and current were recorded every 15 min, while solar insolation and ambient temperature were monitored to assess environmental effects. Chemical oxygen demand (COD) was measured to evaluate wastewater treatment performance. The configuration with continuous aeration and mixing achieved the best performance, reaching a maximum voltage of 563.2 mV and a peak power output of 250.58 µW. Compared with baseline Cell 1, Cell 5 showed a 72.5% higher Week 6 maximum power density. The final COD concentration in Cell 5 was 12.4% lower than that measured in baseline Cell 1; this represents an endpoint difference rather than a reactor-specific COD removal efficiency. Exploratory correlation analysis showed configuration-dependent associations between electrical output and ambient conditions but did not identify a consistent positive relationship between solar insolation and power generation. These results demonstrate that combined aeration and mixing can improve DCMFC performance under realistic outdoor conditions and support the development of scalable, low-resource systems for decentralized bioenergy generation and wastewater treatment. Full article
Show Figures

Figure 1

23 pages, 1607 KB  
Article
Simulation and Optimization of V2G Energy Exchange in an Energy Community Using MATLAB and Multi-Objective Genetic Algorithm Optimization
by Mohammad Talha Yaar Khan and Jozsef Menyhart
Batteries 2026, 12(4), 143; https://doi.org/10.3390/batteries12040143 - 17 Apr 2026
Cited by 1 | Viewed by 1018
Abstract
The Vehicle-to-Grid (V2G) technology is considered one of the best solutions for integrating renewable energy systems; however, most literature reports favorable economic results using synthetic data, without accounting for seasonal or market limitations. The current research presents the results of the MATLAB R2023b [...] Read more.
The Vehicle-to-Grid (V2G) technology is considered one of the best solutions for integrating renewable energy systems; however, most literature reports favorable economic results using synthetic data, without accounting for seasonal or market limitations. The current research presents the results of the MATLAB R2023b (Version 23.2, MathWorks, Natick, MA, USA) simulation of the 100-household energy community in Debrecen, Hungary, with 30 electric vehicles (EVs) using entirely simulation-based Lithium Iron Phosphate (LiFePO4) batteries, a simulation-based 150 kW solar photovoltaic (PV) system, and a simulation-based 200 kW wind power system, using real meteorological data for January 2024. The optimization of charging/discharging for electric vehicles was performed using a multi-objective genetic algorithm (GA) over 30 days at a 15 min time resolution, accounting for stochastic loads and temperature effects on battery degradation, with a sensitivity analysis of key parameters. The results of the optimized solution for the electric vehicle charging/discharging were unexpected: the total energy cost increased by 68.9% ($4337.65 to $7327.54), the peak demand increased by 266.2% (31.9 to 116.9 kW), the degradation cost was $479.63, the load factor was reduced from 0.847 to 0.722, and the SOC constraint was violated for 0.758% of measurements. The V2G is not economically viable under current Hungarian pricing and Central Europe winter conditions. Results are robust for varying parameters using sensitivity analysis and Pareto front tracing. The break-even point is achieved when ratios of peak-to-off-peak prices are above 3.5:1. Seasonal policies and market reforms are critical for V2G viability. Importantly, the influence of inherent design deficiencies in the optimization model on the reported results cannot be ruled out. Full article
(This article belongs to the Special Issue AI-Powered Battery Management and Grid Integration for Smart Cities)
Show Figures

Figure 1

37 pages, 20396 KB  
Article
Comparative Analysis of Peer-to-Peer Energy Trading with Multi-Objective Optimization in Rooftop Photovoltaics-Powered Residential Community
by Mohammad Zeyad, Berk Celik, Timothy M. Hansen, Fabrice Locment and Manuela Sechilariu
Energies 2026, 19(5), 1231; https://doi.org/10.3390/en19051231 - 1 Mar 2026
Cited by 6 | Viewed by 2004
Abstract
The rapid growth of distributed solar energy, such as rooftop photovoltaics (PVs), has revolutionized conventional power systems into more distributed networks, enabling end-users to engage in and trade within the energy market. Maximizing the benefits of rooftop PV panels for residential end-users, including [...] Read more.
The rapid growth of distributed solar energy, such as rooftop photovoltaics (PVs), has revolutionized conventional power systems into more distributed networks, enabling end-users to engage in and trade within the energy market. Maximizing the benefits of rooftop PV panels for residential end-users, including increased renewable energy use and reduced reliance on the utility grid, remains an essential challenge in conventional centralized markets. Moreover, reducing energy consumption may lead to increased peak demand, decreased self-consumption, reduced system flexibility, and reduced grid stability. Therefore, this study presents a transactive energy market framework that integrates home energy management systems (HEMSs) with multi-objective optimization and an aggregator-based, distributed peer-to-peer (P2P) trading strategy to increase rooftop PV utilization and reduce grid dependency within an intra-residential community. The HEMS is structured to integrate rooftop PV production, battery energy storage systems, and smart appliances to offer flexibility through demand response programs in balancing supply and demand by scheduling appliances during periods of rooftop PV production and lower grid prices. Multi-objective (i.e., minimizing energy consumption cost and peak load) optimization problems are solved using the Non-Dominated Sorting Genetic Algorithm-II (NSGA-II) by achieving a Pareto-optimal solution. To validate the reliability and optimality of the NSGA-II results, the same problem formulation is solved using a mixed-integer linear programming approach. Moreover, a Strategic Double Auction with Dynamic Pricing (SDA-DP) strategy is proposed to support P2P trading among consumers and prosumers and thereafter compared with a rule-based zero-intelligence strategy with market-matching rules to analyze the trading performance of the proposed SDA-DP. The results of this comparative analysis (for 10 households, year-long simulation with 15 min time resolution) demonstrate that compared to the baseline case, integrating NSGA-II optimization with SDA-DP trading significantly enhances rooftop PV utilization by 35.11%, reduces grid dependency by 34.04%, and reduces electricity consumption costs by 30.53%, with savings of €1.93 to €6.67 for a single day after participating in the proposed P2P market. Full article
(This article belongs to the Special Issue New Trends in Photovoltaic Power System)
Show Figures

Figure 1

29 pages, 5025 KB  
Article
A Two-Stage T-Norm–Choquet–OWA Resource Aggregator for Multi-UAV Cooperation: Theoretical Proof and Validation
by Linchao Zhang, Jun Peng, Lei Hang and Zhongyang Cheng
Drones 2025, 9(9), 597; https://doi.org/10.3390/drones9090597 - 25 Aug 2025
Viewed by 1442
Abstract
Multi-UAV cooperative missions demand millisecond-level coordination across three key resource dimensions—battery energy, wireless bandwidth, and onboard computing power—where traditional Min or linearly weighted schedulers struggle to balance safety with efficiency. We propose a prediction-enhanced two-stage T-norm–Choquet–OWA resource aggregator. First, an LSTM-EMA model forecasts [...] Read more.
Multi-UAV cooperative missions demand millisecond-level coordination across three key resource dimensions—battery energy, wireless bandwidth, and onboard computing power—where traditional Min or linearly weighted schedulers struggle to balance safety with efficiency. We propose a prediction-enhanced two-stage T-norm–Choquet–OWA resource aggregator. First, an LSTM-EMA model forecasts resource trajectories 3 s ahead; next, a first-stage T-norm (min) pinpoints the bottleneck resource, and a second-stage Choquet–OWA, driven by an adaptive interaction measure ϕ, elastically compensates according to instantaneous power usage, achieving a “bottleneck-first, efficiency-recovery” coordination strategy. Theoretical analysis establishes monotonicity, tight bounds, bottleneck prioritization, and Lyapunov stability, with node-level complexity of only O(1). In joint simulations involving 360 UAVs, the method holds the average round-trip time (RTT) at 55 ms, cutting latency by 5%, 10%, 15%, and 20% relative to Min, DRL-PPO, single-layer OWA, and WSM, respectively. Jitter remains within 11 ms, the packet-loss rate stays below 0.03%, and residual battery increases by about 12% over the best heuristic baseline. These results confirm the low-latency, high-stability benefits of the prediction-based peak-shaving plus two-stage fuzzy aggregation approach for large-scale UAV swarms. Full article
(This article belongs to the Section Drone Communications)
Show Figures

Figure 1

16 pages, 5452 KB  
Article
Study on the Solidification and Heat Release Characteristics of Flexible Heat Storage Filled with PCM Composite
by Tielei Yan, Gang Wang, Dong Zhang, Changxin Qi, Shuangshuang Zhang, Peiqing Li and Gaosheng Wei
Energies 2025, 18(14), 3760; https://doi.org/10.3390/en18143760 - 16 Jul 2025
Cited by 1 | Viewed by 1724
Abstract
Phase change materials (PCMs) have significant potential for utilization due to their high energy storage density and excellent safety in energy storage. In this research, a flexible heat storage device using the stable supercooling of sodium acetate trihydrate composite is developed, enabling on-demand [...] Read more.
Phase change materials (PCMs) have significant potential for utilization due to their high energy storage density and excellent safety in energy storage. In this research, a flexible heat storage device using the stable supercooling of sodium acetate trihydrate composite is developed, enabling on-demand heat release through controlled solidification initiation. The solidification and heat release characteristics are investigated in experiments. The results indicate that the heat release characteristics of this heat storage device are closely linked to the crystallization process of the PCM. During the experiment, based on whether external intervention was needed for the solidification process, the PCM manifested two separate solidification modes—specifically, spontaneous self-solidification and triggered-solidification. Meanwhile, the heat release rates, temperature changes, and crystal morphologies were observed in the two solidification modes. Compared with spontaneous self-solidification, triggered-solidification achieved a higher peak surface temperature (53.6 °C vs. 46.2 °C) and reached 45 °C significantly faster (5 min vs. 15 min). Spontaneous self-solidification exhibited slower, uncontrollable heat release with dendritic crystals, while triggered-solidification provided rapid, controllable heat release with dense filamentous crystals. This controllable switching between modes offers key practical advantages, allowing the device to provide either rapid, high-power heat discharge or slower, sustained release as required by the application. According to the crystal solidification theory, the different supercooling degrees are the main reasons for the two solidification modes exhibiting different solidification characteristics. During solidification, the growth rate of SAT crystals exhibits substantial disparities across diverse experiments. In this research, the maximum axial growth rate is 2564 μm/s, and the maximum radial growth rate is 167 μm/s. Full article
(This article belongs to the Special Issue Heat Transfer Principles and Applications)
Show Figures

Figure 1

30 pages, 7787 KB  
Article
Coordinated Control of the Volt-Var Optimization Problem Under PV-Based Microgrid Integration into the Power Distribution System: Using the Harmony Search Algorithm
by Gulcihan Ozdemir, Pierluigi Siano, Smitha Joyce Pinto and Mohammed AL-Numay
Smart Cities 2025, 8(2), 45; https://doi.org/10.3390/smartcities8020045 - 10 Mar 2025
Cited by 1 | Viewed by 2795
Abstract
A coordinated control for the volt-var optimization (VVO) problem is presented using load tap changer transformers, voltage regulators, and capacitor banks with the integration of a PV-based microgrid. The harmony search (HS) algorithm, which is a metaheuristic-based optimization algorithm, was used to determine [...] Read more.
A coordinated control for the volt-var optimization (VVO) problem is presented using load tap changer transformers, voltage regulators, and capacitor banks with the integration of a PV-based microgrid. The harmony search (HS) algorithm, which is a metaheuristic-based optimization algorithm, was used to determine global optimum settings of related devices to operate efficiently under changing conditions. The major objectives of volt-var optimization were to reduce power losses, peak power demands, and voltage variations in the distribution circuit while maintaining voltages within the permitted range at all nodes and under all loading conditions. The problem was a mixed integer nonlinear problem with discrete integer variables; binary variables for the capacitor status on/off, voltage regulator taps as integers, and continuous variables; the current output of the microgrid; and nonlinear electric circuit equations. The simulations were verified using the IEEE 13-node test circuit. Daily load profiles of the main power system grid and the microgrid’s PV were used with a 15 min resolution. Power flow solutions were produced using the OpenDSS (version 9.5.1.1, year 2022) power distribution system solver. It can be applied to operational and planning purposes. The results showed that active power loss, peak power demand, and voltage fluctuation were significantly reduced by the coordinated control of the volt-var problem. Full article
Show Figures

Figure 1

16 pages, 7214 KB  
Article
Direct Load Control Strategy of Centralized Chiller Plants for Emergency Demand Response: A Field Experiment
by Jie Zhu, Zhe Tian, Jide Niu, Yakai Lu, Haizhu Zhou and Yitong Li
Buildings 2025, 15(3), 462; https://doi.org/10.3390/buildings15030462 - 2 Feb 2025
Cited by 1 | Viewed by 2640
Abstract
As the penetration rate of renewable energy in the power grid increases, the imbalance between power supply and demand has become one of the key issues. Buildings and their heating, ventilation, and air conditioning (HVAC) systems are considered excellent flexible demand response (DR) [...] Read more.
As the penetration rate of renewable energy in the power grid increases, the imbalance between power supply and demand has become one of the key issues. Buildings and their heating, ventilation, and air conditioning (HVAC) systems are considered excellent flexible demand response (DR) resources that can reduce peak loads to alleviate operational pressures on the power grid. Centralized chiller plants are regarded as flexible resources with large capacity and rapid adjustability. The direct load control of chiller plants can respond to the power grid within minutes, making them highly suitable for participation in emergency DR. However, existing studies are generally based on simulations and lack experimental research in actual large-scale buildings to demonstrate the effectiveness of this method and provide related lessons learned. This study conducted field experiments on a centralized chiller plant within an industrial building in Guangdong, China. The results indicate that the strategy of shutting down chiller plants is an effective DR measure. It can complete the load reduction process within 15 min, rapidly decreasing the system power by 380~459 kW, with a maximum duration of up to 50 min, without significantly affecting the thermal comfort of indoor occupants. Additionally, the impact of existing control logic on the participation of chiller plants in the DR process is also discussed. Full article
(This article belongs to the Special Issue Flexible Interaction between Buildings and Power Grid)
Show Figures

Figure 1

16 pages, 3418 KB  
Article
Quantitative Analysis of Energy Storage Demand in Northeast China Using Gaussian Mixture Clustering Model
by Yiwen Yao, Yu Shi, Jing Wang, Zifang Zhang, Xin Xu, Xinhong Wang, Dingheng Wang, Zilai Ou and Zhe Ma
Energies 2025, 18(2), 226; https://doi.org/10.3390/en18020226 - 7 Jan 2025
Viewed by 1504
Abstract
The increased share of new energy sources in Northeast China’s power mix has strained grid stability. Energy storage technologies are essential for maintaining grid stability by addressing peak shaving and frequency regulation challenges. However, a clear quantitative assessment of the region’s energy storage [...] Read more.
The increased share of new energy sources in Northeast China’s power mix has strained grid stability. Energy storage technologies are essential for maintaining grid stability by addressing peak shaving and frequency regulation challenges. However, a clear quantitative assessment of the region’s energy storage needs is lacking, leading to weak grid stability and limited growth potential. This paper analyzes power supply data from Northeast China and models the stochastic characteristics of new energy generation. A joint optimization model for energy storage and thermal power is developed to optimize power allocation for peak shaving and frequency regulation at minimal cost. The empirical distribution method quantifies the relationship between storage power, capacity, and confidence levels, providing insights into the region’s future energy storage demands. The study finds that under 10 typical scenarios, the demand for peaking power at a 15 min scale is ≤500 MW, and the demand for frequency regulation at a 1 min scale is ≤1000 MW. At the 90% confidence level, the required capacity for new energy storage for peak shaving and frequency regulation is 424.13 MWh and 197.65 MWh, respectively. The required power for peak shaving and frequency regulation is 247.88 MW and 527.33 MW, respectively. The durations of peak shaving and frequency regulation are 1.71 h and 0.38 h. It also forecasts the energy storage capacity in the northeast region from 2025 to 2030 under the 5% annual incremental new energy penetration scenario. These findings provide theoretical support for energy storage policies in Northeast China during the 14th Five-Year Plan and practical guidance for accelerating energy storage industrialization. Full article
(This article belongs to the Section A: Sustainable Energy)
Show Figures

Figure 1

16 pages, 1794 KB  
Article
Comparative Analysis of Energy System Demands and Performance Metrics in Professional Soccer Players: Running vs. Cycling Repeated Sprint Tests
by Erkan Tortu and Gökhan Deliceoglu
Appl. Sci. 2024, 14(15), 6518; https://doi.org/10.3390/app14156518 - 26 Jul 2024
Cited by 4 | Viewed by 7486
Abstract
Background: Repeated sprint ability (RSA) is defined as the ability to recover and maintain maximal effort during repeated sprints, recognised as a crucial performance component in team sports. The exercise mode used to test RSA may influence performance and the contributions of different [...] Read more.
Background: Repeated sprint ability (RSA) is defined as the ability to recover and maintain maximal effort during repeated sprints, recognised as a crucial performance component in team sports. The exercise mode used to test RSA may influence performance and the contributions of different energy systems. The primary aim of this study is to address the critical gap between traditional cycling-based anaerobic tests, such as the Wingate test, and the practical, sport-specific demands of running in field-based team sports. Methods: This study involved 32 professional soccer players (age: 21.2 ± 1.3 years; height: 177.8 ± 4.3 cm; and mass: 71.3 ± 6.4 kg). They performed cycling- and running-based repeated sprint tests, with similar total sprint numbers, durations, and recovery times, on different days. Contributions from adenosine triphosphate-phosphocreatine (ATP-PCr), glycolytic, and oxidative systems were estimated through body weight, oxygen uptake (VO2), blood lactate (BLa), and the fast component of excess post-exercise oxygen consumption (EPOC). The VO2 levels and heart rate (HR) were monitored during the rest (10 min), exercise, and recovery (15 min) phases in a breath-by-breath mode using a portable gas exchange system. BLa was measured before (at rest) and 1, 3, 5, 7, and 10 min after the running and cycling tests using a handheld portable analyser. A mono-exponential model estimated the ATP-PCr system contribution, calculated using the fast component of EPOC following the final sprint and the sum of the VO2-time integral during rest intervals. Results: The cycling tests demonstrated significantly higher values for the peak power (PP), mean power (MP), and rate of perceived exertion (RPE) (p < 0.05), while the heart rate peak and blood lactate responses were similar across all modalities. The fatigue index was notably higher in the running tests (p < 0.05). Furthermore, the running tests showed greater contributions in both the percentage and absolute terms from the adenosine triphosphate-phosphocreatine (ATP-PCr) system (p < 0.01), total energy demand (p < 0.05), and total energy expenditure (TEE) (p < 0.01). Notably, the running tests resulted in an increased phosphocreatine breakdown (p < 0.05) and rapid phosphocreatine replenishment (p < 0.01). A simple linear regression analysis highlighted a significant determination coefficient between these performance variables and the contributions of the energy systems, affirming the robustness of the results. The correlation heatmaps further illustrated these relationships, with higher correlations for the PP and MP across modalities (0.41), emphasising the moderate association between cycling and running tests in these metrics. Conclusions: This study elucidated the similarities and differences in energy system contributions and performance outcomes between a cycling and a running repeated sprint protocol, with a comparable total sprint time and work–rest ratio. The findings reveal that a running repeated sprint test elicits a higher energy demand and a higher contribution from the PCr energy system compared to cycling. Performance variables were not associated between running and cycling tests, suggesting those tests cannot be used interchangeably. Full article
(This article belongs to the Special Issue Advances in Performance Analysis and Technology in Sports)
Show Figures

Figure 1

27 pages, 7733 KB  
Article
Data Acquisition Filtering Focused on Optimizing Transmission in a LoRaWAN Network Applied to the WSN Forest Monitoring System
by Thadeu Brito, Beatriz Flamia Azevedo, João Mendes, Matheus Zorawski, Florbela P. Fernandes, Ana I. Pereira, José Rufino, José Lima and Paulo Costa
Sensors 2023, 23(3), 1282; https://doi.org/10.3390/s23031282 - 22 Jan 2023
Cited by 10 | Viewed by 3904
Abstract
Developing innovative systems and operations to monitor forests and send alerts in dangerous situations, such as fires, has become, over the years, a necessary task to protect forests. In this work, a Wireless Sensor Network (WSN) is employed for forest data acquisition to [...] Read more.
Developing innovative systems and operations to monitor forests and send alerts in dangerous situations, such as fires, has become, over the years, a necessary task to protect forests. In this work, a Wireless Sensor Network (WSN) is employed for forest data acquisition to identify abrupt anomalies when a fire ignition starts. Even though a low-power LoRaWAN network is used, each module still needs to save power as much as possible to avoid periodic maintenance since a current consumption peak happens while sending messages. Moreover, considering the LoRaWAN characteristics, each module should use the bandwidth only when essential. Therefore, four algorithms were tested and calibrated along real and monitored events of a wildfire. The first algorithm is based on the Exponential Smoothing method, Moving Averages techniques are used to define the other two algorithms, and the fourth uses the Least Mean Square. When properly combined, the algorithms can perform a pre-filtering data acquisition before each module uses the LoRaWAN network and, consequently, save energy if there is no necessity to send data. After the validations, using Wildfire Simulation Events (WSE), the developed filter achieves an accuracy rate of 0.73 with 0.5 possible false alerts. These rates do not represent a final warning to firefighters, and a possible improvement can be achieved through cloud-based server algorithms. By comparing the current consumption before and after the proposed implementation, the modules can save almost 53% of their batteries when is no demand to send data. At the same time, the modules can maintain the server informed with a minimum interval of 15 min and recognize abrupt changes in 60 s when fire ignition appears. Full article
(This article belongs to the Special Issue Intelligent Monitoring, Control and Optimization in Industries 4.0)
Show Figures

Graphical abstract

23 pages, 3820 KB  
Article
Complex Network Model Reveals the Impact of Inspiratory Muscle Pre-Activation on Interactions among Physiological Responses and Muscle Oxygenation during Running and Passive Recovery
by Fúlvia Barros Manchado-Gobatto, Ricardo Silva Torres, Anita Brum Marostegan, Felipe Marroni Rasteiro, Charlini Simoni Hartz, Marlene Aparecida Moreno, Allan Silva Pinto and Claudio Alexandre Gobatto
Biology 2022, 11(7), 963; https://doi.org/10.3390/biology11070963 - 25 Jun 2022
Cited by 13 | Viewed by 4446
Abstract
Although several studies have focused on the adaptations provided by inspiratory muscle (IM) training on physical demands, the warm-up or pre-activation (PA) of these muscles alone appears to generate positive effects on physiological responses and performance. This study aimed to understand the effects [...] Read more.
Although several studies have focused on the adaptations provided by inspiratory muscle (IM) training on physical demands, the warm-up or pre-activation (PA) of these muscles alone appears to generate positive effects on physiological responses and performance. This study aimed to understand the effects of inspiratory muscle pre-activation (IMPA) on high-intensity running and passive recovery, as applied to active subjects. In an original and innovative investigation of the impacts of IMPA on high-intensity running, we proposed the identification of the interactions among physical characteristics, physiological responses and muscle oxygenation in more and less active muscle to a running exercise using a complex network model. For this, fifteen male subjects were submitted to all-out 30 s tethered running efforts preceded or not preceded by IMPA, composed of 2 × 15 repetitions (1 min interval between them) at 40% of the maximum individual inspiratory pressure using a respiratory exercise device. During running and recovery, we monitored the physiological responses (heart rate, blood lactate, oxygen saturation) and muscle oxygenation (in vastus lateralis and biceps brachii) by wearable near-infrared spectroscopy (NIRS). Thus, we investigated four scenarios: two in the tethered running exercise (with or without IMPA) and two built into the recovery process (after the all-out 30 s), under the same conditions. Undirected weighted graphs were constructed, and four centrality metrics were analyzed (Degree, Betweenness, Eigenvector, and Pagerank). The IMPA (40% of the maximum inspiratory pressure) was effective in increasing the peak and mean relative running power, and the analysis of the complex networks advanced the interpretation of the effects of physiological adjustments related to the IMPA on exercise and recovery. Centrality metrics highlighted the nodes related to muscle oxygenation responses (in more and less active muscles) as significant to all scenarios, and systemic physiological responses mediated this impact, especially after IMPA application. Our results suggest that this respiratory strategy enhances exercise, recovery and the multidimensional approach to understanding the effects of physiological adjustments on these conditions. Full article
Show Figures

Figure 1

14 pages, 693 KB  
Article
Day-Ahead Forecast of Electric Vehicle Charging Demand with Deep Neural Networks
by Gilles Van Kriekinge, Cedric De Cauwer, Nikolaos Sapountzoglou, Thierry Coosemans and Maarten Messagie
World Electr. Veh. J. 2021, 12(4), 178; https://doi.org/10.3390/wevj12040178 - 3 Oct 2021
Cited by 49 | Viewed by 7083
Abstract
The increasing penetration rate of electric vehicles, associated with a growing charging demand, could induce a negative impact on the electric grid, such as higher peak power demand. To support the electric grid, and to anticipate those peaks, a growing interest exists for [...] Read more.
The increasing penetration rate of electric vehicles, associated with a growing charging demand, could induce a negative impact on the electric grid, such as higher peak power demand. To support the electric grid, and to anticipate those peaks, a growing interest exists for forecasting the day-ahead charging demand of electric vehicles. This paper proposes the enhancement of a state-of-the-art deep neural network to forecast the day-ahead charging demand of electric vehicles with a time resolution of 15 min. In particular, new features have been added on the neural network in order to improve the forecasting. The forecaster is applied on an important use case of a local charging site of a hospital. The results show that the mean-absolute error (MAE) and root-mean-square error (RMSE) are respectively reduced by 28.8% and 19.22% thanks to the use of calendar and weather features. The main achievement of this research is the possibility to forecast a high stochastic aggregated EV charging demand on a day-ahead horizon with a MAE lower than 1 kW. Full article
Show Figures

Figure 1

17 pages, 4313 KB  
Article
Real-Time Load Variability Control Using Energy Storage System for Demand-Side Management in South Korea
by Kyo Beom Han, Jaesung Jung and Byung O Kang
Energies 2021, 14(19), 6292; https://doi.org/10.3390/en14196292 - 2 Oct 2021
Cited by 11 | Viewed by 4103
Abstract
In today’s power systems, the widespread adoption of smart grid applications requires sophisticated control of load variability for effective demand-side management (DSM). Conventional Energy Storage System (ESS)-based DSM methods in South Korea are limited to real-time variability control owing to difficulties with model [...] Read more.
In today’s power systems, the widespread adoption of smart grid applications requires sophisticated control of load variability for effective demand-side management (DSM). Conventional Energy Storage System (ESS)-based DSM methods in South Korea are limited to real-time variability control owing to difficulties with model development using customers’ load profiles from sampling with higher temporal resolution. Herein, this study thus proposes a method of controlling the variability of customers’ load profiles for real-time DSM using customer-installed ESSs. To optimize the reserved capacity for the proposed maximum demand control within ESSs, this study also proposes a hybrid method of load generation, which synthesizes approaches based on Markov Transition Matrix (MTM) and Artificial Neuron Network (ANN) to estimate load variations every 15 min and, in turn reserve capacity in ESSs. The proposed ESS-based DSM strategy primarily reserves capacity in ESSs based on estimated variation in load, and performs real-time maximum demand control with the reserved capacity during scheduled peak shaving operations. To validate the proposed methods, this study used load profiles accumulated from industrial and general (i.e., commercial) customers under the time-of-use (TOU) rate. Simulation verified the improved performance of the proposed ESS-based DSM method for all customers, and results of Kolmogorov-Smirnov (K–S) testing indicate advances in the proposed hybrid estimation beyond the stand-alone estimation using the MTM- or ANN-based approach. Full article
(This article belongs to the Special Issue Advanced ESS Operation to Support Grid Stability and Reliability)
Show Figures

Figure 1

Back to TopTop