Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (83)

Search Parameters:
Keywords = buoyancy cooling

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
31 pages, 4347 KiB  
Article
Optimizing Passive Thermal Enhancement via Embedded Fins: A Multi-Parametric Study of Natural Convection in Square Cavities
by Saleh A. Bawazeer
Energies 2025, 18(15), 4098; https://doi.org/10.3390/en18154098 - 1 Aug 2025
Viewed by 135
Abstract
Internal fins are commonly utilized as a passive technique to enhance natural convection, but their efficiency depends on complex interplay between fin design, material properties, and convective strength. This study presents an extensive numerical analysis of buoyancy-driven flow in square cavities containing a [...] Read more.
Internal fins are commonly utilized as a passive technique to enhance natural convection, but their efficiency depends on complex interplay between fin design, material properties, and convective strength. This study presents an extensive numerical analysis of buoyancy-driven flow in square cavities containing a single horizontal fin on the hot wall. Over 9000 simulations were conducted, methodically varying the Rayleigh number (Ra = 10 to 105), Prandtl number (Pr = 0.1 to 10), and fin characteristics, such as length, vertical position, thickness, and the thermal conductivity ratio (up to 1000), to assess their overall impact on thermal efficiency. Thermal enhancements compared to scenarios without fins are quantified using local and average Nusselt numbers, as well as a Nusselt number ratio (NNR). The results reveal that, contrary to conventional beliefs, long fins positioned centrally can actually decrease heat transfer by up to 11.8% at high Ra and Pr due to the disruption of thermal plumes and diminished circulation. Conversely, shorter fins located near the cavity’s top and bottom wall edges can enhance the Nusselt numbers for the hot wall by up to 8.4%, thereby positively affecting the development of thermal boundary layers. A U-shaped Nusselt number distribution related to fin placement appears at Ra ≥ 103, where edge-aligned fins consistently outperform those positioned mid-height. The benefits of high-conductivity fins become increasingly nonlinear at larger Ra, with advantages limited to designs that minimally disrupt core convective patterns. These findings challenge established notions regarding passive thermal enhancement and provide a predictive thermogeometric framework for designing enclosures. The results can be directly applied to passive cooling systems in electronics, battery packs, solar thermal collectors, and energy-efficient buildings, where optimizing heat transfer is vital without employing active control methods. Full article
Show Figures

Figure 1

35 pages, 2895 KiB  
Review
Ventilated Facades for Low-Carbon Buildings: A Review
by Pinar Mert Cuce and Erdem Cuce
Processes 2025, 13(7), 2275; https://doi.org/10.3390/pr13072275 - 17 Jul 2025
Viewed by 671
Abstract
The construction sector presently consumes about 40% of global energy and generates 36% of CO2 emissions, making facade retrofits a priority for decarbonising buildings. This review clarifies how ventilated facades (VFs), wall assemblies that interpose a ventilated air cavity between outer cladding [...] Read more.
The construction sector presently consumes about 40% of global energy and generates 36% of CO2 emissions, making facade retrofits a priority for decarbonising buildings. This review clarifies how ventilated facades (VFs), wall assemblies that interpose a ventilated air cavity between outer cladding and the insulated structure, address that challenge. First, the paper categorises VFs by structural configuration, ventilation strategy and functional control into four principal families: double-skin, rainscreen, hybrid/adaptive and active–passive systems, with further extensions such as BIPV, PCM and green-wall integrations that couple energy generation or storage with envelope performance. Heat-transfer analysis shows that the cavity interrupts conductive paths, promotes buoyancy- or wind-driven convection, and curtails radiative exchange. Key design parameters, including cavity depth, vent-area ratio, airflow velocity and surface emissivity, govern this balance, while hybrid ventilation offers the most excellent peak-load mitigation with modest energy input. A synthesis of simulation and field studies indicates that properly detailed VFs reduce envelope cooling loads by 20–55% across diverse climates and cut winter heating demand by 10–20% when vents are seasonally managed or coupled with heat-recovery devices. These thermal benefits translate into steadier interior surface temperatures, lower radiant asymmetry and fewer drafts, thereby expanding the hours occupants remain within comfort bands without mechanical conditioning. Climate-responsive guidance emerges in tropical and arid regions, favouring highly ventilated, low-absorptance cladding; temperate and continental zones gain from adaptive vents, movable insulation or PCM layers; multi-skin adaptive facades promise balanced year-round savings by re-configuring in real time. Overall, the review demonstrates that VFs constitute a versatile, passive-plus platform for low-carbon buildings, simultaneously enhancing energy efficiency, durability and indoor comfort. Future advances in smart controls, bio-based materials and integrated energy-recovery systems are poised to unlock further performance gains and accelerate the sector’s transition to net-zero. Emerging multifunctional materials such as phase-change composites, nanostructured coatings, and perovskite-integrated systems also show promise in enhancing facade adaptability and energy responsiveness. Full article
(This article belongs to the Special Issue Sustainable Development of Energy and Environment in Buildings)
Show Figures

Figure 1

13 pages, 3038 KiB  
Article
Assessment of Global and Detailed Chemical Kinetics in Supercritical Combustion for Hydrogen Gas Turbines
by Sylwia Oleś, Jakub Mularski, Halina Pawlak-Kruczek, Abhishek K. Singh and Artur Pozarlik
Energies 2025, 18(13), 3380; https://doi.org/10.3390/en18133380 - 27 Jun 2025
Viewed by 373
Abstract
Supercritical combustion is a promising technique for improving the efficiency and reducing the emissions of next-generation gas turbines. However, accurately modeling combustion under these conditions remains a challenge, particularly due to the complexity of chemical kinetics. This study aims to evaluate the applicability [...] Read more.
Supercritical combustion is a promising technique for improving the efficiency and reducing the emissions of next-generation gas turbines. However, accurately modeling combustion under these conditions remains a challenge, particularly due to the complexity of chemical kinetics. This study aims to evaluate the applicability of a reduced global reaction mechanism compared to the detailed Foundational Fuel Chemistry Model 1.0 (FFCM-1) when performing hydrogen combustion with supercritical carbon dioxide and argon as diluents. Computational fluid dynamics simulations were conducted in two geometries: a simplified tube for isolating chemical effects and a combustor with cooling channels for practical evaluation. The analysis focuses on the evaluation of velocity, temperature, and the water vapor mass fraction distributions inside the combustion chamber. The results indicate good agreement between the global and detailed mechanisms, with average relative errors below 2% for supercritical argon and 4% for supercritical carbon dioxide. Both models captured key combustion behaviors, including buoyancy-driven flame asymmetry caused by the high density of supercritical fluids. The findings suggest that global chemistry models can serve as efficient tools for simulating supercritical combustion processes, making them valuable for the design and optimization of future supercritical gas turbine systems. Full article
(This article belongs to the Special Issue Advancements in Gas Turbine Aerothermodynamics)
Show Figures

Figure 1

23 pages, 5565 KiB  
Article
Advanced Numerical Analysis of Heat Transfer in Medium and Large-Scale Heat Sinks Using Cascaded Lattice Boltzmann Method
by Fatima Zahra Laktaoui Amine, Mustapha El Alami, Elalami Semma, Hamza Faraji, Ayoub Gounni and Amina Mourid
Appl. Sci. 2025, 15(13), 7205; https://doi.org/10.3390/app15137205 - 26 Jun 2025
Viewed by 316
Abstract
Medium- and large-scale heat sinks are critical for thermal load management in high-performance systems. However, their high heat flux densities and limited space complicate cooling, leading to risks of overheating, performance degradation, or failure. This study employs the Cascaded Lattice Boltzmann Method (CLBM) [...] Read more.
Medium- and large-scale heat sinks are critical for thermal load management in high-performance systems. However, their high heat flux densities and limited space complicate cooling, leading to risks of overheating, performance degradation, or failure. This study employs the Cascaded Lattice Boltzmann Method (CLBM) to enhance their thermal performance. This numerical approach is known for being stable, accurate when dealing with complex boundaries, and efficient when computing in parallel. The numerical code was validated against a benchmark configuration and an experimental setup to ensure its reliability and accuracy. While previous studies have explored mixed convection in cavities or heat sinks, few have addressed configurations involving side air injection and boundary conditions periodicity in the transition-to-turbulent regime. This gap limits the understanding of realistic cooling strategies for compact systems. Focusing on mixed convection in the transition-to-turbulent regime, where buoyancy and forced convection interact, the study investigates the impact of Rayleigh number values (5×107 to 5×108) and Reynolds number values (103 to 3×103) on heat transfer. Simulations were conducted in a rectangular cavity with periodic boundary conditions on the vertical walls. Two heat sources are located on the bottom wall (Th = 50 °C). Two openings, one on each side of the two hot sources, force a jet of fresh air in from below. An opening at the level of the cavity ceiling’s axis of symmetry evacuates the hot air. Mixed convection drives the flow, exhibiting complex multicellular structures influenced by the control parameters. Calculating the average Nusselt number (Nu) across the surfaces of the heat sink reveals significant dependencies on the Reynolds number. The proposed correlation between Nu and Re, developed specifically for this configuration, fills the current gap and provides valuable insights for optimizing heat transfer efficiency in engineering applications. Full article
(This article belongs to the Special Issue Recent Research on Heat and Mass Transfer)
Show Figures

Figure 1

26 pages, 5033 KiB  
Article
Laminar Natural Convection in a Square Cavity with a Horizontal Fin on the Heated Wall: A Numerical Study of Fin Position and Thermal Conductivity Effects
by Saleh A. Bawazeer
Energies 2025, 18(13), 3335; https://doi.org/10.3390/en18133335 - 25 Jun 2025
Cited by 1 | Viewed by 326
Abstract
This study numerically examines laminar natural convection within a square cavity that has a horizontally attached adiabatic fin on its heated vertical wall. The analysis employed the finite element method to investigate how fin position, length, thickness, and thermal conductivity affect heat transfer [...] Read more.
This study numerically examines laminar natural convection within a square cavity that has a horizontally attached adiabatic fin on its heated vertical wall. The analysis employed the finite element method to investigate how fin position, length, thickness, and thermal conductivity affect heat transfer behavior over a broad spectrum of Rayleigh numbers (Ra = 10 to 106) and Prandtl numbers (Pr = 0.1 to 10). The findings indicate that the geometric configuration and the properties of the fluid largely influence the thermal disturbances caused by the fin. At lower Ra values, conduction is the primary mechanism, resulting in minimal impact from the fin. However, as Ra rises, convection becomes increasingly significant, with the fin positioned at mid-height (Yfin = 0.5), significantly improving thermal mixing and flow symmetry, especially for high-Pr fluids. Extending the fin complicates vortex dynamics, whereas thickening the fin improves conductive heat transfer, thereby enhancing convection to the fluid. A new fluid-focused metric, the normalized Nusselt ratio (NNR), is introduced to evaluate the true thermal contribution of fin geometry beyond area-based scaling. It exhibits a non-monotonic response to geometric changes, with peak enhancement observed at high Ra and Pr. The findings provide practical guidance for designing passive thermal management systems in sealed enclosures, such as electronics housings, battery modules, and solar thermal collectors, where active cooling is infeasible. This study offers a scalable reference for optimizing natural convection performance in laminar regimes by characterizing the interplay between buoyancy, fluid properties, and fin geometry. Full article
Show Figures

Figure 1

30 pages, 24334 KiB  
Article
Enhanced Heat Removal Using Buoyancy-Tracking Exhaust Vents for Moving Heat Sources in Industrial Environments: CFD and Experimental Study
by Zhongwu Xie, Wei Yin, Xiaoli Hao, Shaobo Zhang, Theofanis Psomas, Torbjörn Lindholm and Lars Ekberg
Buildings 2025, 15(10), 1719; https://doi.org/10.3390/buildings15101719 - 19 May 2025
Viewed by 485
Abstract
High-temperature and high-pollution mobile sources are frequently encountered in industrial environments. Fixed-position exhaust outlets often fail to promptly remove heat and contaminants when these sources are in motion, leading to local accumulation and reduced indoor air quality. This study proposes a novel mobile [...] Read more.
High-temperature and high-pollution mobile sources are frequently encountered in industrial environments. Fixed-position exhaust outlets often fail to promptly remove heat and contaminants when these sources are in motion, leading to local accumulation and reduced indoor air quality. This study proposes a novel mobile exhaust system capable of tracking and dynamically aligning with moving emission sources to improve heat removal and cooling efficiency. Three configurations were evaluated: (1) a fixed exhaust outlet, (2) an exhaust vent moving synchronously with the heat source, and (3) a buoyancy-driven tracking exhaust outlet. Small-scale experiments and CFD simulations using dynamic mesh techniques were conducted. The results showed that the synchronous system reduced ambient temperature by an average of 0.25 to 2.3 °C compared to the fixed outlet, while the buoyancy-tracking system achieved an additional 0.15 to 2.5 °C reduction. The study also introduces a correlation between thermal plume inclination and the Archimedes number, providing a predictive basis for exhaust positioning. Given the similar dispersion patterns of heat and airborne pollutants, the proposed system holds promise for both thermal management and contaminant control in dynamic industrial environments. Furthermore, the system may offer critical advantages in emergency ventilation scenarios involving intense heat or hazardous pollutant outbreaks. Full article
(This article belongs to the Special Issue Building Energy-Saving Technology—3rd Edition)
Show Figures

Figure 1

22 pages, 7708 KiB  
Article
Top and Side Leakage Effects on Thermoregulation and Moisture Retention with Facemask Wearing
by Kian Barari, Xiuhua Si, Rozhin Hajian and Jinxiang Xi
J. Respir. 2025, 5(2), 5; https://doi.org/10.3390/jor5020005 - 3 Apr 2025
Viewed by 1185
Abstract
Background/Objectives: Mask-wearing-induced discomfort often leads to unconscious loosening of the mask to relieve the discomfort, thereby compromising protective efficacy. This study investigated how leakage flows affect mask-associated thermoregulation and vapor trapping to inform better mask designs. An integrated ambience–mask–face–airway model with various mask-wearing [...] Read more.
Background/Objectives: Mask-wearing-induced discomfort often leads to unconscious loosening of the mask to relieve the discomfort, thereby compromising protective efficacy. This study investigated how leakage flows affect mask-associated thermoregulation and vapor trapping to inform better mask designs. An integrated ambience–mask–face–airway model with various mask-wearing misfits was developed. Methods: The transient warming/cooling effects, thermal buoyancy force, tissue heat generation, vapor phase change, and fluid/heat/mass transfer through a porous medium were considered in this model, which was validated using Schlieren imaging, a thermal camera, and velocity/temperature measurements. Leakages from the top and side of the mask were analyzed in comparison to a no-leak scenario under cyclic respiration conditions. Results: A significant inverse relationship was observed between mask leakage and facial temperature/humidity. An equivalent impact from buoyancy forces and exhalation flow inertia was observed both experimentally and numerically, indicating a delicate balance between natural convection and forced convection, which is sensitive to leakage flows and critical in thermo-humidity regulation. For a given gap, the leakage fraction was not constant within one breathing cycle but constantly increased during exhalation. Persistently higher temperatures were found in the nose region throughout the breathing cycle in a sealed mask and were mitigated during inhalation when gaps were present. Vapor condensation occurred within the mask medium during exhalation in all mask-wearing cases. Conclusions: The thermal and vapor temporal variation profiles were sensitive to the location of the gap, highlighting the feasibility of leveraging temperature and relative humidity to test mask fit and quantify leakage fraction. Full article
(This article belongs to the Collection Feature Papers in Journal of Respiration)
Show Figures

Figure 1

24 pages, 8640 KiB  
Article
Numerical Study of Influence of Nanofluids on the Optimization of Heat Transfer in Immersion Cooling Systems
by Abdelilah Makaoui, Youssef Admi, Mohammed Amine Moussaoui and Ahmed Mezrhab
Processes 2025, 13(3), 620; https://doi.org/10.3390/pr13030620 - 21 Feb 2025
Viewed by 1567
Abstract
The present study evaluates the heat transfer performance of an immersion liquid cooling system, utilizing copper-water (Cu-water) nanofluids under various flow and geometric conditions, including different Reynolds and Rayleigh numbers, nanoparticle volume fractions, and block spacing configurations. To this end, numerical simulations were [...] Read more.
The present study evaluates the heat transfer performance of an immersion liquid cooling system, utilizing copper-water (Cu-water) nanofluids under various flow and geometric conditions, including different Reynolds and Rayleigh numbers, nanoparticle volume fractions, and block spacing configurations. To this end, numerical simulations were conducted to assess the impact of these parameters on the system’s temperature distribution and overall cooling efficiency. The findings indicate that augmenting the Reynolds number from 100 to 500, and the nanoparticle volume fraction from 0% to 5%, at a Rayleigh number of 105, results in substantial enhancements in heat transfer, with improvements reaching up to 193.8%. Furthermore, an increase in the Rayleigh number from 103 to 106, in conjunction with elevated nanoparticle concentrations at a Reynolds number of 500, yielded a heat transfer enhancement of up to 36.3%. These findings demonstrate that higher Reynolds and Rayleigh numbers promote better heat dissipation through increased convective flow and buoyancy-driven convection. Furthermore, the study underscores the pivotal function of block spacing in maximizing cooling efficacy. While closer spacing results in higher temperatures, wider spacing improves heat transfer efficiency by reducing thermal interference between blocks. The study emphasizes the synergistic effect of an enhanced thermal conductivity, strong convective flow, and optimal geometric configurations in maximizing cooling efficiency. These findings are of crucial importance for the design of more efficient thermal management systems, with applications in electronics cooling, energy systems, and industrial processes. Full article
(This article belongs to the Special Issue Applications of Nanofluids and Nano-PCMs in Heat Transfer)
Show Figures

Figure 1

16 pages, 4900 KiB  
Article
Passive Dissipation of Canopy Urban Heat Through Double Skin Façades
by Chih-Hong Huang, Ching-Hsun Wang and Yu-Ping Tsaur
Buildings 2025, 15(3), 430; https://doi.org/10.3390/buildings15030430 - 29 Jan 2025
Viewed by 999
Abstract
In the face of global warming, mitigating the urban heat island effect has become an important concern worldwide. This study applies the principle of buoyancy ventilation formed by sunlight in double skin façades (DSFs) to improve the thermal environment outside buildings by discharging [...] Read more.
In the face of global warming, mitigating the urban heat island effect has become an important concern worldwide. This study applies the principle of buoyancy ventilation formed by sunlight in double skin façades (DSFs) to improve the thermal environment outside buildings by discharging heat through temperature and pressure differences. The study subject is a 15 × 30 × 40 m residential concrete building situated in a subtropical climate. The lower opening of the DSF faces the outdoor environment; heat is absorbed through this opening from the ground environment and then evacuated up to above the urban canopy layer heat island in order to cool pedestrian environments on the ground. We used numerical simulation to analyze the cooling potential of this DSF in summer daytime conditions. The results show that the DSF can successfully transport heat energy and discharge it above the urban canopy layer. Significant cooling effects were observed in both the horizontal and vertical spaces on the leeward side of the building DSF through the passage of surface heat, thereby reducing the load of indoor air conditioning. Full article
(This article belongs to the Section Architectural Design, Urban Science, and Real Estate)
Show Figures

Figure 1

26 pages, 4712 KiB  
Article
An Experimental Study on the Flow Boiling Heat Transfer Characteristics of Deionized Water Under Rotational Hypergravity
by Gen Li, Yiling Zhao, Xiaojie Zhang, Jianxun Xie and Xiande Fang
Aerospace 2025, 12(2), 75; https://doi.org/10.3390/aerospace12020075 - 21 Jan 2025
Viewed by 1005
Abstract
Flow boiling heat transfer in micro-channels under hypergravity conditions is a crucial research area for developing efficient cooling systems in aerospace applications. This experimental study investigated the flow boiling heat transfer characteristics of deionized water in a tube with a 2 mm diameter [...] Read more.
Flow boiling heat transfer in micro-channels under hypergravity conditions is a crucial research area for developing efficient cooling systems in aerospace applications. This experimental study investigated the flow boiling heat transfer characteristics of deionized water in a tube with a 2 mm diameter under various gravitational conditions ranging from normal gravity (1 g) to hypergravity (up to 5.1 g) by employing a centrifugal rotating platform. The study systematically analyzes the effects of gravity level, vapor quality, mass flux, and heat flux on the flow boiling heat transfer coefficient (HTC) of deionized water. Experimental results reveal that hypergravity significantly influenced the HTC at a higher vapor quality with up to a 40% deviation and was less pronounced at lower values with an approximately 10% deviation. This deterioration is attributed to the complex interplay of centrifugal force, the Coriolis force, buoyancy, and the specific properties of water, leading to vapor–liquid stratification and hindering effective heat transfer. Meanwhile, critical heat flux was found to increase with increasing gravity acceleration at high vapor qualities. This enhancement is attributed to improved buoyancy effects, liquid replenishment, and altered flow patterns under hypergravity conditions. Furthermore, five existing correlations for predicting flow boiling HTCs were evaluated against the experimental data, and all the correlations showed overestimated results. The consistent over-prediction by these correlations highlights the need for modifications to better capture heat transfer mechanisms under hypergravity conditions. Full article
(This article belongs to the Special Issue Experimental and Numerical Investigation of Flow Instability)
Show Figures

Figure 1

44 pages, 9048 KiB  
Article
Artificial Neural Network and Response Surface Methodology-Driven Optimization of Cu–Al2O3/Water Hybrid Nanofluid Flow in a Wavy Enclosure with Inclined Periodic Magnetohydrodynamic Effects
by Tarikul Islam, Sílvio Gama and Marco Martins Afonso
Mathematics 2025, 13(1), 78; https://doi.org/10.3390/math13010078 - 28 Dec 2024
Cited by 3 | Viewed by 2126
Abstract
This study explores the optimization of a Cu–Al2O3/water hybrid nanofluid within an irregular wavy enclosure under inclined periodic MHD effects. Hybrid nanofluids, with different mixture ratios of copper (Cu) and alumina (Al2O3) nanoparticles in water, [...] Read more.
This study explores the optimization of a Cu–Al2O3/water hybrid nanofluid within an irregular wavy enclosure under inclined periodic MHD effects. Hybrid nanofluids, with different mixture ratios of copper (Cu) and alumina (Al2O3) nanoparticles in water, are used in this study. Numerical simulations using the Galerkin residual-based finite-element method (FEM) are conducted to solve the governing PDEs. At the same time, artificial neural networks (ANNs) and response surface methodology (RSM) are employed to optimize thermal performance by maximizing the average Nusselt number (Nuav), the key indicator of thermal transport efficiency. Thermophysical properties such as viscosity and thermal conductivity are evaluated for validation against experimental data. The results include visual representations of heatlines, streamlines, and isotherms for various physical parameters. Additionally, Nuav, friction factors, and thermal efficiency index are analyzed using different nanoparticle ratios. The findings show that buoyancy and MHD parameters significantly influence heat transfer, friction, and thermal efficiency. The addition of Cu nanoparticles improves heat transport compared to Al2O3 nanofluid, demonstrating the superior thermal conductivity of the Cu–Al2O3/water hybrid nanofluid. The results also indicate that adding Al2O3 nanoparticles to the Cu/water nanofluid diminishes the heat transport rate. The waviness of the geometry shows a significant impact on thermal management as well. Moreover, the statistical RSM analysis indicates a high R2 value of 98.88% for the response function, which suggests that the model is well suited for predicting Nuav. Furthermore, the ANN model demonstrates high accuracy with a mean squared error (MSE) of 0.00018, making it a strong alternative to RSM analysis. Finally, this study focuses on the interaction between the hybrid nanofluid, a wavy geometry, and MHD effects, which can optimize heat transfer and contribute to energy-efficient cooling or heating technologies. Full article
(This article belongs to the Special Issue Artificial Intelligence for Fluid Mechanics)
Show Figures

Figure 1

13 pages, 4509 KiB  
Article
The Development of a Converter Transformer Fire Model Based on the Fire Dynamics Simulator and the Analysis of Cooling Mechanisms of Spraying and Coating
by Xinhan Qiao, Yijiao Wang, Yuchang Zhang, Le Yu, Dongdong Zhang and Zhi Wang
Appl. Sci. 2024, 14(23), 11337; https://doi.org/10.3390/app142311337 - 5 Dec 2024
Viewed by 982
Abstract
This research develops a numerical fire model for a converter transformer utilizing the Fire Dynamics Simulator (FDS). The model’s accuracy was validated through comprehensive evaluations of temperature distribution, radiative heat transfer, and mass burning rate. Additionally, the cooling efficacy of fire-resistant coating and [...] Read more.
This research develops a numerical fire model for a converter transformer utilizing the Fire Dynamics Simulator (FDS). The model’s accuracy was validated through comprehensive evaluations of temperature distribution, radiative heat transfer, and mass burning rate. Additionally, the cooling efficacy of fire-resistant coating and fine water mist with varying droplet sizes was investigated. The results indicate that fireproof coating significantly reduces the surface temperature of the transformer, thereby enhancing its fire resistance. Specifically, temperature reductions of 57.68%, 45.63%, 37.78%, and 36.78% were recorded at different facade heights. Furthermore, the cooling performance of fine water mist is strongly influenced by droplet size, primarily due to thermal buoyancy effects. Larger droplets (400 μm) exhibited the most efficient cooling effect directly beneath the spray, achieving temperature reductions of up to 67%. In contrast, smaller droplets (100 μm) showed diminished cooling performance in certain regions, owing to the compensatory buoyancy of hot air, even resulting in an 11% temperature increase in some cases. During the flame stabilization phase, the mass burning rate stabilized between 0.056 kg/(m2·s) and 0.070 kg/(m2·s), with the inhibitory effect of small particle mist becoming pronounced only after 450 s. These findings offer critical insights for optimizing fire protection strategies for converter transformers, highlighting the significance of cooling mechanisms and material properties. Full article
(This article belongs to the Section Electrical, Electronics and Communications Engineering)
Show Figures

Figure 1

35 pages, 99630 KiB  
Article
Tornadic Storm over the Foothills of Central Nepal Himalaya
by Toshihiro Kitada, Sajan Shrestha, Sangeeta Maharjan, Suresh Bhattarai and Ram Prasad Regmi
Meteorology 2024, 3(4), 412-446; https://doi.org/10.3390/meteorology3040020 - 1 Dec 2024
Viewed by 1862
Abstract
On the evening of 31 March 2019, Parsa and Bara Districts in central Nepal were severely hit by a wind storm which was the first documented tornadic incidence in Nepal.In this paper, we investigate the background of the tornado formation via numerical simulations [...] Read more.
On the evening of 31 March 2019, Parsa and Bara Districts in central Nepal were severely hit by a wind storm which was the first documented tornadic incidence in Nepal.In this paper, we investigate the background of the tornado formation via numerical simulations with the WRF-ARW model. The results show that: (1) a flow situation favorable to the generation of mesocyclones was formed by a combination of local plain-to-mountain winds consisting of warm and humid southwesterly wind in the lower atmosphere and synoptic northwesterly wind aloft over the southern foothills of the Himalayan Mountain range, leading to significant vertical wind shear and strong buoyancy; (2) the generated mesocyclone continuously shed rain-cooled outflow with 600∼800 m depth above the ground into the Chitwan valley while moving southeastward along the Mahabharat Range at the northeastern rim of the Chitwan valley; (3) the cold outflow propagated in the valley, forming a front; and (4) the tornado was generated when this cold outflow passed over the Siwalik Hills bordering the southern rim of the Chitwan valley. At this point, descending flow around a high mountain generated positive vertical vorticity near the ground; blocking by this high mountain and channeling through a mountain pass enhanced updrafts at the front by forming a hydraulic jump. These updrafts amplified the positive vertical vorticity via stretching, and this interaction of the cold outflow with the Siwalik Hills contributed to tornadogenesis. The simulated location and time of the disaster showed generally good agreement with the reported location and time. Full article
Show Figures

Figure 1

21 pages, 11066 KiB  
Article
Finite Element Analysis of Laminar Natural Convection in a Differentially Heated Porous Cavity Using the Darcy–Brinkman Model
by Benabderrahmane Farhat, Noureddine Kaid, Sultan Alqahtani, Younes Menni, Badr M. Alshammari and Lioua Kolsi
Processes 2024, 12(9), 1974; https://doi.org/10.3390/pr12091974 - 13 Sep 2024
Cited by 3 | Viewed by 1221
Abstract
This study delves into the convective heat transfer phenomena within a square cavity that houses a porous medium, analyzing the effects of Darcy (Da) and Rayleigh (Ra) numbers on the thermal and fluid dynamic behavior within the system. Utilizing a combination of computational [...] Read more.
This study delves into the convective heat transfer phenomena within a square cavity that houses a porous medium, analyzing the effects of Darcy (Da) and Rayleigh (Ra) numbers on the thermal and fluid dynamic behavior within the system. Utilizing a combination of computational fluid dynamics (CFD) and the finite element method (FEM), the research focuses on steady-state, laminar flow conditions in two dimensions. The cavity, which is impermeable at its boundaries, contains a centrally located square region filled with a porous, isotropic material. The thermal environment is controlled with insulated horizontal walls and vertically positioned walls that experience sinusoidal temperature variations. The study examines how variations in the permeability of the porous medium (Da numbers ranging from 10−1 to 10−4) and the buoyancy-driven flow strength (Ra numbers spanning from 102 to 105) influence the velocity fields and heat transfer rates, with results expressed through Nusselt number (Nu) distributions. The findings reveal that higher Ra numbers, particularly at 105, significantly intensify convection within the cavity, thereby boosting local rates of heat transfer, especially in the central vertical section. The research identifies that optimal flow resistance in the porous medium occurs within the Da number range of 10−3 to 10−4. These insights are critical for advancing thermal management techniques, particularly in the natural cooling of electronic devices and improving insulation methods. Full article
(This article belongs to the Section AI-Enabled Process Engineering)
Show Figures

Figure 1

29 pages, 8342 KiB  
Article
Anti-Gravity 3D Pulsating Heat Pipe for Cooling Electric Vehicle Batteries
by Ji-Su Lee, Su-Jong Kim, Woo-Sung Han and Seok-Ho Rhi
Energies 2024, 17(10), 2283; https://doi.org/10.3390/en17102283 - 9 May 2024
Cited by 5 | Viewed by 2279
Abstract
This study proposes an anti-gravity 3D pulsating heat pipe (PHP) for cooling pouch batteries in electric vehicles. The 3D PHP envelops the battery cells and rapidly transfers heat generated from the batteries to the bottom cold plate. While the batteries generate heat on [...] Read more.
This study proposes an anti-gravity 3D pulsating heat pipe (PHP) for cooling pouch batteries in electric vehicles. The 3D PHP envelops the battery cells and rapidly transfers heat generated from the batteries to the bottom cold plate. While the batteries generate heat on their frontal surface during charging and discharging, structural characteristics lead to localized heat accumulation at the electrode lead tabs. Therefore, to address frontal heating, Pattern A with a consistent height for the 3D PHP and Pattern B with varying heights to enhance heat transfer in the localized heating area were designed. The target application involved creating a battery simulator for 340 × 100 mm pouch battery cells, considering the battery’s heat generation characteristics. The experiments for the thermal characteristics were conducted, considering factors such as the working fluid (methanol, Novec7100), filling ratio, supplied heat, and orientation. Additionally, to observe internal flow mechanisms, a special experimental apparatus was used, employing transparent fluorine rubber tubes to observe the flow mechanism of the 3D PHP. In the results of the thermal characteristics, the optimal filling ratio was 15% when heat generation levels of 50 W and 100 W were supplied and 20% when 150 W was supplied. The impact of orientation yielded varied results depending on the pattern and working fluid, attributed to the complex interplay of flow momentum due to orientation changes and the influence of the working fluid’s buoyancy under anti-gravity conditions. Pattern B, designed with the goal of applying a localized heat model, exhibited relatively decreased heat transfer performance in areas with varying heights. As the distance from the varying height portion increased, temperature oscillations and heat transfer became more active. These results suggest that variations in the shape of the 3D PHP could be a primary design variable for crafting localized heat models. Observations of internal flow revealed that the 3D PHP, with its unique shape and operation under anti-gravity conditions, exhibits longer and more irregular cycles compared to gravity-assist PHPs, transferring heat through rapid oscillations of internal working fluid liquid/vapor slug/plug. The potential of 3D PHPs for cooling electric vehicle batteries is suggested by these findings, and further experimentation is planned to evaluate the optimal design and applicability. Full article
Show Figures

Figure 1

Back to TopTop