Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (7)

Search Parameters:
Keywords = biological specimens: atomic force microscopy

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
18 pages, 4433 KB  
Article
Acid-Induced Surface Degradation of Metallic Biomaterials: Alloy-Dependent Behavior and Implications for Surface Functionality
by Réka Niklai, Péter Szabó, Judit Kopniczky, Tímea Dergez, Béla Kolarovszki, Orsolya Kada, Ákos Nagy, Kinga Turzó and Dorottya Frank
J. Funct. Biomater. 2026, 17(6), 268; https://doi.org/10.3390/jfb17060268 - 1 Jun 2026
Viewed by 629
Abstract
Metallic biomaterials are frequently exposed to chemically aggressive environments that may compromise surface integrity and corrosion resistance. Acidic media containing organic acids represent a relevant challenge for metallic systems, as they can destabilize passive oxide layers and promote surface degradation processes. The present [...] Read more.
Metallic biomaterials are frequently exposed to chemically aggressive environments that may compromise surface integrity and corrosion resistance. Acidic media containing organic acids represent a relevant challenge for metallic systems, as they can destabilize passive oxide layers and promote surface degradation processes. The present in vitro study investigated acid-induced surface alterations in four commercially relevant orthodontic alloys—nickel–titanium (NiTi), copper–nickel–titanium (CuNiTi), titanium–molybdenum alloy (TMA), and stainless steel—as representative metallic biomaterials. Specimens were exposed to two commercially available acidic beverages with distinct pH conditions, followed by analysis of surface morphology, roughness, and elemental composition using atomic force microscopy (AFM), scanning electron microscopy (SEM), and energy-dispersive X-ray spectroscopy (EDS). The results demonstrated pronounced alloy-dependent differences in degradation behavior. Stainless steel and TMAs exhibited significant increases in surface roughness and morphological alterations, whereas NiTi-based alloys showed comparatively stable surface characteristics. Elemental analysis revealed material-specific compositional variations, suggesting selective surface modification processes under acidic exposure. These differences can be attributed to variations in alloy composition, microstructure, and the stability of passive oxide layers, which collectively govern corrosion resistance in metallic systems. The findings provide insight into acid-induced degradation mechanisms in metallic biomaterials and highlight the importance of material-dependent corrosion behavior under chemically aggressive conditions. These observations may have implications for surface-mediated biological responses and long-term functional performance of metallic biomaterials. Full article
(This article belongs to the Section Dental Biomaterials)
Show Figures

Graphical abstract

33 pages, 7384 KB  
Review
Nanoscale Imaging of Biological Tissues: Techniques, Challenges and Emerging Frontiers
by Rohit Kajla, Rebecca Leija-Cardenas, Meghraj Magadi Shivalingaiah, Muhammad Waqas Shabbir and Zihao Ou
Nanomaterials 2025, 15(23), 1752; https://doi.org/10.3390/nano15231752 - 22 Nov 2025
Cited by 3 | Viewed by 2459
Abstract
Nanoscale characterization of biological tissues bridges molecular identity with structural, mechanical, and chemical organization, enabling high-resolution insights into intact specimens. This review provides a comprehensive overview of the principal imaging modalities that resolve cellular and subcellular features in biological tissues. Electron microscopy techniques [...] Read more.
Nanoscale characterization of biological tissues bridges molecular identity with structural, mechanical, and chemical organization, enabling high-resolution insights into intact specimens. This review provides a comprehensive overview of the principal imaging modalities that resolve cellular and subcellular features in biological tissues. Electron microscopy techniques offer ultrastructural details and volumetric reconstructions with sectioning and tomography techniques. Optical nanoscopy approaches such as single-molecule localization microscopy, stimulated emission depletion microscopy, structural illumination microscopy, and expansion microscopy achieve fluorescence-based mapping with tens-of-nanometer precision. Complementary platforms like atomic force microscopy and nanoscale secondary ion mass spectrometry extend nanoscale characterization into mechanical and chemical domains. Artificial intelligence has emerged as a transformative tool for segmentation, image restoration, and volumetric reconstruction, addressing bottlenecks in throughput and interpretability. From practical applications on biological tissues, we evaluate each technique’s strengths, limitations, and potential for clinical applications. The review concludes with a discussion on emerging directions, including live-tissue nanoscopy, correlative light and electron microscopy, and machine-driven high-throughput imaging for further investigation of nanoscale biological structures and functions. Full article
(This article belongs to the Special Issue Nanomaterials for Biomedical and Environmental Applications)
Show Figures

Figure 1

20 pages, 16333 KB  
Review
The Burgeoning Importance of Nanomotion Sensors in Microbiology and Biology
by Marco Girasole and Giovanni Longo
Biosensors 2025, 15(7), 455; https://doi.org/10.3390/bios15070455 - 15 Jul 2025
Cited by 2 | Viewed by 1641
Abstract
Nanomotion sensors have emerged as a pivotal technology in microbiology and biology, leveraging advances in nanotechnology, microelectronics, and optics to provide a highly sensitive, label-free detection of biological activity and interactions. These sensors were first limited to nanomechanical oscillators like atomic force microscopy [...] Read more.
Nanomotion sensors have emerged as a pivotal technology in microbiology and biology, leveraging advances in nanotechnology, microelectronics, and optics to provide a highly sensitive, label-free detection of biological activity and interactions. These sensors were first limited to nanomechanical oscillators like atomic force microscopy cantilevers, but now they are expanding into new, more intriguing setups. The idea is to convert the inherent nanoscale movements of living organisms—a direct manifestation of their metabolic activity—into measurable signals. This review highlights the evolution and diverse applications of nanomotion sensing. Key methodologies include Atomic Force Microscopy-based sensors, optical nanomotion detection, graphene drum sensors, and optical fiber-based sensors, each offering unique advantages in sensitivity, cost, and applicability. The analysis of complex nanomotion data is increasingly supported by advanced modeling and the integration of artificial intelligence and machine learning, enhancing pattern recognition and automation. The versatility and real-time, label-free nature of nanomotion sensing position it as a transformative tool that could revolutionize diagnostics, therapeutics, and fundamental biological research. Full article
Show Figures

Figure 1

13 pages, 2471 KB  
Article
Positive Effects of UV-Photofunctionalization of Titanium Oxide Surfaces on the Survival and Differentiation of Osteogenic Precursor Cells—An In Vitro Study
by Marco Roy, Alessandro Corti, Barbara Dorocka-Bobkowska and Alfonso Pompella
J. Funct. Biomater. 2022, 13(4), 265; https://doi.org/10.3390/jfb13040265 - 25 Nov 2022
Cited by 12 | Viewed by 3294
Abstract
Introduction: The UVC-irradiation (“UV-photofunctionalization”) of titanium dental implants has proved to be capable of removing carbon contamination and restoring the ability of titanium surfaces to attract cells involved in the process of osteointegration, thus significantly enhancing the biocompatibility of implants and favoring the [...] Read more.
Introduction: The UVC-irradiation (“UV-photofunctionalization”) of titanium dental implants has proved to be capable of removing carbon contamination and restoring the ability of titanium surfaces to attract cells involved in the process of osteointegration, thus significantly enhancing the biocompatibility of implants and favoring the post-operative healing process. To what extent the effect of UVC irradiation is dependent on the type or the topography of titanium used, is still not sufficiently established. Objective: The present study was aimed at analyzing the effects of UV-photofunctionalization on the TiO2 topography, as well as on the gene expression patterns and the biological activity of osteogenic cells, i.e., osteogenic precursors cultured in vitro in the presence of different titanium specimens. Methodology: The analysis of the surface roughness was performed by atomic force microscopy (AFM) on machined surface grade 2, and sand-blasted/acid-etched surface grades 2 and 4 titanium specimens. The expression of the genes related with the process of healing and osteogenesis was studied in the MC3T3-E1 pre-osteoblastic murine cells, as well as in MSC murine stem cells, before and after exposure to differently treated TiO2 surfaces. Results: The AFM determinations showed that the surface topographies of titanium after the sand-blasting and acid-etching procedures, look very similar, independently of the grade of titanium. The UVC-irradiation of the TiO2 surface was found to induce an increase in the cell survival, attachment and proliferation, which was positively correlated with an increased expression of the osteogenesis-related genes Runx2 and alkaline phosphatase (ALP). Conclusion: Overall, our findings expand and further support the current view that UV-photofunctionalization can indeed restore biocompatibility and osteointegration of TiO2 implants, and suggest that this at least in part occurs through a stimulation of the osteogenic differentiation of the precursor cells. Full article
Show Figures

Figure 1

12 pages, 1959 KB  
Article
In Vitro Assessment of the Cell Metabolic Activity, Cytotoxicity, Cell Attachment, and Inflammatory Reaction of Human Oral Fibroblasts on Polyetheretherketone (PEEK) Implant–Abutment
by Tzu-Yu Peng, Yin-Hwa Shih, Shih-Min Hsia, Tong-Hong Wang, Po-Jung Li, Dan-Jae Lin, Kuo-Ting Sun, Kuo-Chou Chiu and Tzong-Ming Shieh
Polymers 2021, 13(17), 2995; https://doi.org/10.3390/polym13172995 - 3 Sep 2021
Cited by 38 | Viewed by 5813
Abstract
The purpose of this research is to compare the cytotoxicity of polyetheretherketone (PEEK) and polyetherketoneketone (PEKK) with conventional dental implant–abutment materials, namely titanium alloy (Ti-6Al-4V) and yttria-stabilized tetragonal zirconia polycrystal (Y-TZP), to evaluate the cell metabolic activity, cytotoxicity, and inflammation potential of human [...] Read more.
The purpose of this research is to compare the cytotoxicity of polyetheretherketone (PEEK) and polyetherketoneketone (PEKK) with conventional dental implant–abutment materials, namely titanium alloy (Ti-6Al-4V) and yttria-stabilized tetragonal zirconia polycrystal (Y-TZP), to evaluate the cell metabolic activity, cytotoxicity, and inflammation potential of human oral fibroblasts (HOF) on these materials. Disk-shaped specimens were designed and prepared via a dental computer-aided manufacturing technology system. Surface topography, roughness, and free energy were investigated by atomic force microscope and contact angle analyzer; cell metabolic activity and cytotoxicity by MTT assay; and morphological changes by scanning electron microscopy (SEM). The effect of pro-inflammatory gene expression was evaluated by RT-qPCR. The obtained data were analyzed with one-way analysis of variance and post-hoc Tukey’s honest significant difference tests. PEEK and PEKK exhibited higher submicron surface roughness (0.04 μm) and hydrophobicity (>80°) than the control. Although the cell activity of PEEK was lower than that of Ti-6Al-4V and Y-TZP for the first 24 h (p < 0.05), after 48 h there was no difference (p > 0.05). According to the cell cytotoxicity and the pro-inflammatory cytokine gene expression assays, there was no difference between the materials (p > 0.05). SEM observations indicated that HOF adhered poorly to PEKK but properly to Ti-6Al-4V, Y-TZP, and PEEK. PEEK and PEKK show comparable epithelial biological responses to Ti-6Al-4V and Y-TZP as implant–abutment materials. Between the two polymeric materials, the PEEK surface, where the HOF showed better cell metabolic activity and cytotoxicity, was a more promising implant–abutment material. Full article
(This article belongs to the Special Issue Polymeric Materials for Dental Applications II)
Show Figures

Figure 1

12 pages, 2724 KB  
Article
Bioactivity of an Experimental Dental Implant with Anodized Surface
by Maria Fernanda Lima Villaça-Carvalho, Juliani Caroline Ribeiro de Araújo, Juliana Mariano Beraldo, Renata Falchete do Prado, Mari Eli Leonelli de Moraes, Luiz Roberto Coutinho Manhães Junior, Eduardo Norberto Codaro, Heloisa Andrea Acciari, João Paulo Barros Machado, Natal Nerímio Regone, Anderson Oliveira Lobo, Fernanda Roberta Marciano and Luana Marotta Reis de Vasconcellos
J. Funct. Biomater. 2021, 12(2), 39; https://doi.org/10.3390/jfb12020039 - 7 Jun 2021
Cited by 10 | Viewed by 4308
Abstract
Background: Several studies proved that anodic oxidation improves osseointegration. This study aimed to optimize osseointegration through anodization in dental implants, obtaining anatase phase and controlled nanotopography. Methods: The division of the groups with 60 titanium implants was: control (CG); sandblasted (SG); anodized (AG): [...] Read more.
Background: Several studies proved that anodic oxidation improves osseointegration. This study aimed to optimize osseointegration through anodization in dental implants, obtaining anatase phase and controlled nanotopography. Methods: The division of the groups with 60 titanium implants was: control (CG); sandblasted (SG); anodized (AG): anodized pulsed current (duty cycle 30%, 30 V, 0.2 A and 1000 Hz). Before surgery, surface characterization was performed using Atomic Force Microscopy (AFM), Scanning Electron Microscopy (SEM), X-ray Dispersive Energy Spectroscopy (EDS) and Raman Spectroscopy. For in vivo tests, 10 New Zealand white rabbits received an implant from each group. The sacrifice period was 2 and 6 weeks (n = 5) and the specimens were subjected to computed microtomography (μCT) and reverse torque test. Results: AFM and SEM demonstrated a particular nanotopography on the surface in AG; the anatase phase was proved by Raman spectroscopy. In the μCT and in the reverse torque test, the AG group presented better results than the other groups. Conclusion: The chemical composition and structure of the TiO2 film were positively affected by the anodizing technique, intensifying the biological characteristics in osseointegration. Full article
(This article belongs to the Special Issue Advanced Functional Biomaterials for Dental Implants)
Show Figures

Figure 1

16 pages, 4230 KB  
Article
Tip Pressure on Semicircular Specimens in Tapping Mode Atomic Force Microscopy in Viscous Fluid Environments
by Hua-Ju Shih, Ching-Liang Dai and Po-Jen Shih
Sensors 2017, 17(10), 2182; https://doi.org/10.3390/s17102182 - 22 Sep 2017
Cited by 1 | Viewed by 4327
Abstract
Tapping mode (TM) atomic force microscopy (AFM) in a liquid environment is widely used to measure the contours of biological specimens. The TM triggers the AFM probe approximately at the resonant frequencies and controls the tip such that it periodically touches the specimen [...] Read more.
Tapping mode (TM) atomic force microscopy (AFM) in a liquid environment is widely used to measure the contours of biological specimens. The TM triggers the AFM probe approximately at the resonant frequencies and controls the tip such that it periodically touches the specimen along the scanning path. The AFM probe and its tip produce a hydrodynamic pressure on the probe itself and press the specimen. The tip to specimen size ratio is known to affect the measurement accuracy of AFM, however, few studies have focused on the hydrodynamic pressure caused by the effects of specimen size. Such pressure affects the contour distortion of the biological specimen. In this study, a semi-analytical method is employed for a semicircular specimen to analyze the vorticity and pressure distributions for specimens of various sizes and at various tip locations. Changes in pressure distribution, fluid spin motion, and specimen deformation are identified as the tip approaches the specimen. The results indicate the following: the specimen surface experiences the highest pressure when the specimen diameter equals the tip width; the vorticity between tip and specimen is complex when the tip is close to the specimen center line; and the specimen inflates when the tip is aligned with the specimen center line. Full article
(This article belongs to the Section Physical Sensors)
Show Figures

Figure 1

Back to TopTop