Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (10)

Search Parameters:
Keywords = air-lift pumping system

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
22 pages, 2159 KB  
Article
Performance Evaluation and Carbon Emission Reduction Analysis of a Coupled Photovoltaic Thermal and Air Source Heat Pump Heating System in Office Buildings
by Yuxin Zheng, Yabin Jin, Wenhan Song and Zizhen Huang
Energies 2026, 19(16), 3867; https://doi.org/10.3390/en19163867 - 18 Aug 2026
Viewed by 181
Abstract
PV/T collectors and Air Source Heat Pump (ASHP) are widely studied for building heating, but solar intermittency and ASHP low-temperature frosting limit their large-scale deployment. A novel PV/T-ASHP coupled heating system is proposed to cut building carbon emissions and relieve ASHP performance degradation [...] Read more.
PV/T collectors and Air Source Heat Pump (ASHP) are widely studied for building heating, but solar intermittency and ASHP low-temperature frosting limit their large-scale deployment. A novel PV/T-ASHP coupled heating system is proposed to cut building carbon emissions and relieve ASHP performance degradation in cold zones. Circulating water cools PV/T panels to boost power generation, and the warmed water preheats ASHP evaporator inlet air to reduce frosting and defrosting frequency. With a Xi’an office building as the research object, validated TRNSYS 18.0 models are established for comparative analysis with conventional systems and cross-climate evaluation in Xi’an, Beijing, Shanghai and Chengdu. Results show the new system lifts PV/T combined efficiency by 17.56%, reduces energy consumption by 19.9%, and achieves an average COP of 3.2. Across climate zones, its COP rises 11.5–24.6% and 50-year carbon emissions fall 16.4–26.2%, supporting low-carbon heating promotion for office buildings. Full article
(This article belongs to the Special Issue Advanced Technologies for Energy-Efficient Buildings—2nd Edition)
Show Figures

Figure 1

27 pages, 3479 KB  
Article
The Water Lifting Performance of a Photovoltaic Sprinkler Irrigation System Regulated by Solar-Coupled Compressed-Air Energy Storage
by Xiaoqing Zhong, Maosheng Ge, Zhengwen Tang, Pute Wu, Xin Hui, Qianwen Zhang, Qingyan Zhang and Khusen Sh. Gafforov
Agriculture 2026, 16(2), 154; https://doi.org/10.3390/agriculture16020154 - 8 Jan 2026
Cited by 1 | Viewed by 1581
Abstract
Solar-driven irrigation, a promising clean technology for agricultural water conservation, is constrained by mismatched photovoltaic (PV) pump outflow and irrigation demand, alongside unstable PV output. While compressed-air energy storage (CAES) shows mitigation potential, existing studies lack systematic explorations of pump water-lifting characteristics and [...] Read more.
Solar-driven irrigation, a promising clean technology for agricultural water conservation, is constrained by mismatched photovoltaic (PV) pump outflow and irrigation demand, alongside unstable PV output. While compressed-air energy storage (CAES) shows mitigation potential, existing studies lack systematic explorations of pump water-lifting characteristics and supply capacity under coupled meteorological and air pressure effects, limiting its practical promotion. This study focuses on a solar-coupled compressed-air energy storage regulated sprinkler irrigation system (CAES-SPSI). Integrating experimental and theoretical methods, it establishes dynamic flow models for three DC diaphragm pumps considering combined PV output and outlet back pressure, introduces pressure loss and drop coefficients to construct a nozzle pressure dynamic model via calibration and iteration, and conducts a 1-hectare corn field case study. The results indicate the following: pump flow increases with PV power and decreases with outlet pressure (model deviation < 9.24%); nozzle pressure in pulse spraying shows logarithmic decline; CAES-SPSI operates 10 h/d, with hourly water-lifting capacity of 0.317–1.01 m3/h and daily cumulation of 6.71 m3; and the low-intensity and long-duration mode extends irrigation time, maintaining total volume and optimal soil moisture. This study innovatively incorporates dynamic air pressure potential energy into meteorological-PV coupling analysis, providing a universal method for quantifying pump flow changes, clarifying CAES-SPSI’s water–energy coupling mechanism, and offering a design basis for its agricultural application feasibility. Full article
(This article belongs to the Section Agricultural Water Management)
Show Figures

Figure 1

25 pages, 6781 KB  
Article
Numerical Simulation on Hybrid Lifting Operation of Polymetallic Nodules and Rare-Earth Elements-Rich Mud by Air-Lift Pump in Deep Sea around Minamitorishima Island
by Yoshiyuki Shimizu, Masatoshi Sugihara, Koichiro Fujinaga, Kentaro Nakamura and Yasuhiro Kato
J. Mar. Sci. Eng. 2025, 13(2), 267; https://doi.org/10.3390/jmse13020267 - 31 Jan 2025
Cited by 3 | Viewed by 2354
Abstract
Polymetallic nodules and REE-rich mud under the seabed of 5500–5700 m water depth around Minamitorishima island are promising and attractive for exploration and development. Following our previous research, numerical analysis was used to investigate the unsteady flow characteristics and the lifting performance of [...] Read more.
Polymetallic nodules and REE-rich mud under the seabed of 5500–5700 m water depth around Minamitorishima island are promising and attractive for exploration and development. Following our previous research, numerical analysis was used to investigate the unsteady flow characteristics and the lifting performance of a commercial production system using an air-lift pump for hybrid lifting, lifting both polymetallic nodules and REE-rich mud. Gas–liquid–solid three-phase flow and gas–liquid two-phase flow in the system were analyzed using the one-dimensional drift–flux model. First, the reliability of the schemes and program was verified by comparing the numerical results with the experimental ones. Next, numerical simulations were conducted, in which the model’s dimensions were related to a commercial production system operated in the deep sea around Minamitorishima island, and the conditions fit the expected production rate. The results revealed the unsteady flow characteristics under the operations, such as start-up, shut-down, feed of polymetallic nodules and REE-rich mud, and those associated with disturbances, such as feed rate fluctuations. We demonstrate that the program and the schemes can simulate the unsteady flow characteristics and the lifting performance of a commercial production system with an air-lift pump well, and they can derive useful information and know-how in advance for the safe and continuous operation of the system. Full article
(This article belongs to the Special Issue Deep-Sea Mining Technologies: Recent Developments and Challenges)
Show Figures

Figure 1

24 pages, 6311 KB  
Article
Air-Lift Pumping System for Hybrid Mining of Rare-Earth Elements-Rich Mud and Polymetallic Nodules around Minamitorishima Island
by Yoshiyuki Shimizu, Masatoshi Sugihara, Koichiro Fujinaga, Kentaro Nakamura and Yasuhiro Kato
J. Mar. Sci. Eng. 2024, 12(9), 1470; https://doi.org/10.3390/jmse12091470 - 23 Aug 2024
Cited by 7 | Viewed by 4406
Abstract
REE-rich mud under the seabed at a 5500–5700 m water depth around Minamitorishima island and polymetallic nodules buried in the deep seabed are very promising and attractive to explore and develop. REEs are critical to develop due to the recent paradigm shift to [...] Read more.
REE-rich mud under the seabed at a 5500–5700 m water depth around Minamitorishima island and polymetallic nodules buried in the deep seabed are very promising and attractive to explore and develop. REEs are critical to develop due to the recent paradigm shift to renewable energies based on green technologies. Numerical analysis using a one-dimensional drift–flux model for gas–liquid–solid three-phase flow and gas–liquid two-phase flow was conducted to examine the characteristics of an air-lift pumping system for mining these mineral resources. Empirical equations of REE-rich mud and the physical properties of polymetallic nodules around Minamitorishima island were utilized in the analysis. As a result, the characteristics, i.e., the performance of the system, were clarified in three cases: REE-rich mud, polymetallic nodules, and both. The time transient, i.e., the unsteady characteristics of the system, was also shown, such as the start-up and feeding slurry with REE-rich mud and polymetallic nodules. The findings from the unsteady characteristics will be useful in considering the operation of a real project or a commercial system in the future. Full article
(This article belongs to the Special Issue Deep-Sea Mining Technologies: Recent Developments and Challenges)
Show Figures

Figure 1

23 pages, 6730 KB  
Article
A Novel H2O/LiBr Absorption Heat Pump with Condensation Heat Recovery for Combined Heating and Cooling Production: Energy Analysis for Different Applications
by Juan Prieto, Dereje S. Ayou and Alberto Coronas
Clean Technol. 2023, 5(1), 51-73; https://doi.org/10.3390/cleantechnol5010004 - 31 Dec 2022
Cited by 13 | Viewed by 7117
Abstract
The aim of this study is to analyze the feasibility of the single-effect H2O/LiBr absorption heat pump cycle to produce combined heating and cooling. To achieve this, first, the main changes that the absorption cycle requires are described in comparison with [...] Read more.
The aim of this study is to analyze the feasibility of the single-effect H2O/LiBr absorption heat pump cycle to produce combined heating and cooling. To achieve this, first, the main changes that the absorption cycle requires are described in comparison with the conventional single-effect absorption chiller. Then, the cycle’s operational limits in terms of temperature lift and LiBr crystallization are evaluated. In this sense, driving heat temperatures required for these applications range from 85 °C to 120 °C. The energy and exergy performance (in terms of cooling and heating capacities, cooling and heating coefficient of performance, and exergy coefficient of performance) of the cycle is theoretically studied for five different types of applications that require simultaneous heating and cooling: building air conditioning, a 4th generation district heating and cooling network, a sports center with an indoor swimming pool, a hybrid air conditioning system with an absorption heat pump and a desiccant evaporative cooling system, and simultaneous cooling and water purification application for coastal areas. The system performance in terms of the cooling coefficient of performance varies in the range of 0.812–0.842, in terms of heating coefficient of performance from 0.58 to 1.842, and in terms of exergy coefficient of performance from 0.451 to 0.667. The application with the highest exergy coefficient of performance is the 4th generation district heating and cooling network. Full article
(This article belongs to the Special Issue Synergistic Technologies to Advance in Sustainable Refrigeration)
Show Figures

Figure 1

14 pages, 7894 KB  
Article
Development of a Low-Depth Modular GHX through a Real-Scale Experiment
by Kwonye Kim, Sangmu Bae, Yujin Nam, Euyjoon Lee and Evgueniy Entchev
Energies 2022, 15(3), 698; https://doi.org/10.3390/en15030698 - 18 Jan 2022
Cited by 5 | Viewed by 2535
Abstract
The global energy sector is aiming to rapidly transform energy systems into those less dependent on fossil fuels to reduce their harmful effects on the climate. Although ground source heat pump (GSHP) systems are more efficient than conventional air-source heat pump (ASHP) systems, [...] Read more.
The global energy sector is aiming to rapidly transform energy systems into those less dependent on fossil fuels to reduce their harmful effects on the climate. Although ground source heat pump (GSHP) systems are more efficient than conventional air-source heat pump (ASHP) systems, the high initial investment cost, particularly for a vertical closed-loop type ground heat exchanger (GHX), makes it difficult to incorporate them into small buildings. This paper proposes a low-depth modular GHX for reducing cost and improving the workability of GSHPs. A modular GHX is a cubical structure comprising tubes and buried using an excavator at a depth 4 m below the ground surface. This GHX is manufactured at a factory, carried by a small truck, and then installed by a small lift or a backhoe such that it can be installed in small buildings or narrow spaces at low depths underground. In this research, the performance and feasibility analyses of modular and vertical GHXs were conducted via a real-scale experiment. The results demonstrate that the modular GHX influences the workability of GSHPs by 91% during the heating period and 70% during the cooling period. In contrast to the conventional HVAC, the modular and vertical GHXs could recover the initial investment costs in 4 years and 10 years, respectively. Full article
(This article belongs to the Topic Sustainable Energy Technology)
Show Figures

Figure 1

17 pages, 5437 KB  
Article
Two-Phase Flow Mass Transfer Analysis of Airlift Pump for Aquaculture Applications
by Rashal Abed, Mohamed M. Hussein, Wael H. Ahmed and Sherif Abdou
Fluids 2021, 6(6), 226; https://doi.org/10.3390/fluids6060226 - 16 Jun 2021
Cited by 10 | Viewed by 6471
Abstract
Airlift pumps can be used in the aquaculture industry to provide aeration while concurrently moving water utilizing the dynamics of two-phase flow in the pump riser. The oxygen mass transfer that occurs from the injected compressed air to the water in the aquaculture [...] Read more.
Airlift pumps can be used in the aquaculture industry to provide aeration while concurrently moving water utilizing the dynamics of two-phase flow in the pump riser. The oxygen mass transfer that occurs from the injected compressed air to the water in the aquaculture systems can be experimentally investigated to determine the pump aeration capabilities. The objective of this study is to evaluate the effects of various airflow rates as well as the injection methods on the oxygen transfer rate within a dual injector airlift pump system. Experiments were conducted using an airlift pump connected to a vertical pump riser within a recirculating system. Both two-phase flow patterns and the void fraction measurements were used to evaluate the dissolved oxygen mass transfer mechanism through the airlift pump. A dissolved oxygen (DO) sensor was used to determine the DO levels within the airlift pumping system at different operating conditions required by the pump. Flow visualization imaging and particle image velocimetry (PIV) measurements were performed in order to better understand the effects of the two-phase flow patterns on the aeration performance. It was found that the radial injection method reached the saturation point faster at lower airflow rates, whereas the axial method performed better as the airflow rates were increased. The standard oxygen transfer rate (SOTR) and standard aeration efficiency (SAE) were calculated and were found to strongly depend on the injection method as well as the two-phase flow patterns in the pump riser. Full article
(This article belongs to the Special Issue Multiphase Flow for Energy, Water and Food Applications)
Show Figures

Figure 1

20 pages, 10289 KB  
Article
Remediating Contaminated Groundwater with an Aerated, Direct-Push, Oxidant Delivery System
by James Reece, Mark Christenson, Ann Kambhu, Yusong Li, Clifford E. Harris and Steve Comfort
Water 2020, 12(12), 3383; https://doi.org/10.3390/w12123383 - 2 Dec 2020
Cited by 8 | Viewed by 5994
Abstract
One of the biggest challenges to treating contaminated aquifers with chemical oxidants is achieving uniform coverage of the target zone. In an effort to maximize coverage, we report the design and installation of a novel aerated, slow-release oxidant delivery system that can be [...] Read more.
One of the biggest challenges to treating contaminated aquifers with chemical oxidants is achieving uniform coverage of the target zone. In an effort to maximize coverage, we report the design and installation of a novel aerated, slow-release oxidant delivery system that can be installed by direct-push equipment. By continuously bubbling air beneath a slow-release oxidant in situ, an airlift pump is created that causes water and oxidant to be dispersed from the top of the outer screen and drawn in at the bottom. This continuous circulation pattern around each drive point greatly facilitates the spreading of the oxidant as it slowly dissolves from the wax matrix (i.e., oxidant candle). Given that the aeration rate controls the outward flow of oxidant from the outer screen in all directions, the radius of influence around each drive point is largely a function of the outward velocity of the oxidant exiting the screen and the advection rate opposing the upgradient and lateral spreading. Temporal sampling from three field sites treated with the aerated oxidant system are presented and results show that contaminant concentrations typically decreased 50–99% within 6–9 months after installation. Supporting flow tank experiments that demonstrate oxidant flow patterns and treatment efficacy are also presented. Full article
(This article belongs to the Special Issue Groundwater and Soil Remediation)
Show Figures

Figure 1

24 pages, 5229 KB  
Article
The Effect of Hydraulic Conditions in Barbotage Reactors on Aeration Efficiency
by Sebastian Kujawiak, Małgorzata Makowska and Jakub Mazurkiewicz
Water 2020, 12(3), 724; https://doi.org/10.3390/w12030724 - 6 Mar 2020
Cited by 8 | Viewed by 4069
Abstract
Barbotage reactors such as airlift reactors (ALR) and bubble column reactors (BCR), due to their two-phase flow systems, were investigated in many research papers. In their basic design variants, they are typically used to lift, mix, and aerate liquids, while, when equipped with [...] Read more.
Barbotage reactors such as airlift reactors (ALR) and bubble column reactors (BCR), due to their two-phase flow systems, were investigated in many research papers. In their basic design variants, they are typically used to lift, mix, and aerate liquids, while, when equipped with additional elements in hybrid variants, their individual properties, i.e., lifting, mixing, and aeration of liquids, can significantly change with the same reactor geometry. The object of this study was to develop a hybrid barbotage reactor in various structural design variants. The structure consisted of a barbotage column of 50 mm in diameter, used to transport a water–air mixture outside the reactor (so-called external loop). The installation was additionally equipped with a nozzle in order to improve mixture aeration and circulation efficiency. The nozzle was mounted at various heights of the column pump segment. Additionally, the reactor was equipped with s moving bed in two variants (20% and 40% reactor capacity) in order to determine its effect on the mixture aeration and circulation conditions. Based on the measurement results, aeration curves were prepared for various structural design and column packing variants of the reactor. Properties of the two-phase mixture were determined for both parts—ALR and BCR. Technological and energy parameters of the aeration process were calculated, and the results obtained for the individual structural design variants were compared. It was found that, for the most advantageous design, in terms of aeration efficiency, the aeration nozzle should be placed in the mid-length of the pump segment of the barbotage column, irrespective of the hybrid reactor packing rate with the moving bed. The reactor packing with the moving bed resulted in a decreased mean water velocity in the reactor. For most analyzed structural design variants, the respective packing with the moving bed had no significant effect on aeration efficiency. Only for one structural design variant did the lack of packing significantly improve oxygen levels by as much as approximately 41%. Full article
(This article belongs to the Section Hydraulics and Hydrodynamics)
Show Figures

Figure 1

23 pages, 5100 KB  
Article
Performance Analysis of an Updraft Tower System for Dry Cooling in Large-Scale Power Plants
by Haotian Liu, Justin Weibel and Eckhard Groll
Energies 2017, 10(11), 1812; https://doi.org/10.3390/en10111812 - 9 Nov 2017
Cited by 7 | Viewed by 6563
Abstract
An updraft tower cooling system is assessed for elimination of water use associated with power plant heat rejection. Heat rejected from the power plant condenser is used to warm the air at the base of an updraft tower; buoyancy-driven air flows through a [...] Read more.
An updraft tower cooling system is assessed for elimination of water use associated with power plant heat rejection. Heat rejected from the power plant condenser is used to warm the air at the base of an updraft tower; buoyancy-driven air flows through a recuperative turbine inside the tower. The secondary loop, which couples the power plant condenser to a heat exchanger at the tower base, can be configured either as a constant-pressure pump cycle or a vapor compression cycle. The novel use of a compressor can elevate the air temperature in the tower base to increases the turbine power recovery and decrease the power plant condensing temperature. The system feasibility is evaluated by comparing the net power needed to operate the system versus alternative dry cooling schemes. A thermodynamic model coupling all system components is developed for parametric studies and system performance evaluation. The model predicts that constant-pressure pump cycle consumes less power than using a compressor; the extra compression power required for temperature lift is much larger than the gain in turbine power output. The updraft tower system with a pumped secondary loop can allow dry cooling with less power plant efficiency penalty compared to air-cooled condensers. Full article
(This article belongs to the Section F: Electrical Engineering)
Show Figures

Figure 1

Back to TopTop