14 pages, 6218 KB  
Article
Analysis of the Effect of Human Type I Collagen-Derived Peptide on Bone Regenerative Capacity and Comparison with Various Collagen Materials In Vivo
by Tatsunori Asakura, Tran Thi Thuy Diep, Yuta Ueda, Aoi Yamada, Takahiro Tsuzuno, Naoki Takahashi, Masayuki Miyata, Koichi Tabeta, Masaki Nagata and Ken Matsuda
Medicina 2025, 61(1), 57; https://doi.org/10.3390/medicina61010057 - 2 Jan 2025
Cited by 4 | Viewed by 3208
Abstract
Background and Objectives: Autologous bone grafting is the first choice for reconstructive surgery in bone defects due to trauma or malignant tumors. However, there is an increasing demand for minimally invasive alternatives involving bone regeneration using artificial materials. Biomimetic materials that replicate [...] Read more.
Background and Objectives: Autologous bone grafting is the first choice for reconstructive surgery in bone defects due to trauma or malignant tumors. However, there is an increasing demand for minimally invasive alternatives involving bone regeneration using artificial materials. Biomimetic materials that replicate the body’s microscopic structure, such as Cellnest®, are gaining attention. Cellnest is a xeno-free recombinant peptide based on human type I collagen, containing a rich Arg-Gly-Asp (RGD) motif related to cell adhesion. The aim of this study was to compare the effects of Cellnest with existing collagen materials (Pelnac®, Integra®, Terudermis®) on bone regeneration and elucidate the underlying mechanisms. Materials and Methods: In vivo experiments involved a rat model of calvarial bone defects, in which Cellnest and other collagen materials were implanted into the defect area. Bone formation was assessed after 4 weeks using micro-computed tomography (micro-CT) and histological analysis. In vitro experiments included the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT), adhesion, and migration assays, and a real-time polymerase chain reaction using rapidly expanding cells (RECs) to explore the mechanisms of Cellnest’s bone regenerative capacity. Results: The micro-CT analysis showed that the regenerated bone area was significantly greater in the Cellnest group (72.3%) than in the Pelnac® (25.5%), Integra® (31.6%), and Terudermis® (38.3%) groups. The histological analysis confirmed similar trends, with Cellnest showing 42.2% bone regeneration, outperforming the other materials. The in vitro assays revealed that Cellnest promoted cell proliferation, adhesion, and migration. Gene expression analysis demonstrated that Cellnest significantly increased the levels of the bone formation markers ALP and COL1. Conclusions: Cellnest, a human type I collagen-like peptide rich in RGD motifs, enhances bone regeneration by promoting MSC adhesion and migration, and bone formation-related gene expression. The findings suggest its potential as an effective material for bone defect reconstruction. Full article
(This article belongs to the Section Dentistry and Oral Health)
Show Figures

Figure 1

17 pages, 9347 KB  
Article
Nanofat Improves Vascularization and Tissue Integration of Dermal Substitutes without Affecting Their Biocompatibility
by Francesca Bonomi, Ettore Limido, Andrea Weinzierl, Emmanuel Ampofo, Yves Harder, Michael D. Menger and Matthias W. Laschke
J. Funct. Biomater. 2024, 15(10), 294; https://doi.org/10.3390/jfb15100294 - 3 Oct 2024
Cited by 9 | Viewed by 2687
Abstract
Dermal substitutes require sufficient tissue integration and vascularization to be successfully covered with split-thickness skin grafts. To rapidly achieve this, we provide the proof of principle for a novel vascularization strategy with high translational potential. Nanofat was generated from subcutaneous adipose tissue of [...] Read more.
Dermal substitutes require sufficient tissue integration and vascularization to be successfully covered with split-thickness skin grafts. To rapidly achieve this, we provide the proof of principle for a novel vascularization strategy with high translational potential. Nanofat was generated from subcutaneous adipose tissue of green fluorescence protein (GFP)+ C57BL/6J donor mice and seeded onto small samples (4 mm in diameter) of the clinically approved dermal substitute Integra®. These samples and non-seeded controls were then implanted into full-thickness skin defects in the dorsal skinfold chamber of C57BL/6J wild-type mice and analyzed by intravital fluorescence microscopy, histology and immunohistochemistry over a 14-day period. Nanofat-seeded dermal substitutes exhibited an accelerated vascularization, as indicated by a significantly higher functional microvessel density on days 10 and 14 when compared to controls. This was primarily caused by the reassembly of GFP+ microvascular fragments inside the nanofat into microvascular networks. The improved vascularization promoted integration of the implants into the surrounding host tissue, which finally exhibited an increased formation of a collagen-rich granulation tissue. There were no marked differences in the inflammatory host tissue reaction to nanofat-seeded and control implants. These findings demonstrate that nanofat significantly improves the in vivo performance of dermal substitutes without affecting their biocompatibility. Full article
Show Figures

Figure 1

19 pages, 5669 KB  
Article
Evaluation of Bone Turnover around Short Finned Implants in Atrophic Posterior Maxilla: A Finite Element Study
by Andrii Kondratiev, Vladislav Demenko, Igor Linetskiy, Hans-Werner Weisskircher and Larysa Linetska
Prosthesis 2024, 6(5), 1170-1188; https://doi.org/10.3390/prosthesis6050084 - 24 Sep 2024
Cited by 11 | Viewed by 2982
Abstract
Background/Objectives: Dental implants have emerged as a modern solution for edentulous jaws, showing high success rates. However, the implant’s success often hinges on the patient’s bone quality and quantity, leading to higher failure rates in poor bone sites. To address this issue, [...] Read more.
Background/Objectives: Dental implants have emerged as a modern solution for edentulous jaws, showing high success rates. However, the implant’s success often hinges on the patient’s bone quality and quantity, leading to higher failure rates in poor bone sites. To address this issue, short implants have become a viable alternative to traditional approaches like bone sinus lifting. Among these, Bicon® short implants with a plateau design are popular for their increased surface area, offering potential advantages over threaded implants. Despite their promise, the variability in patient-specific bone quality remains a critical factor influencing implant success and bone turnover regulated by bone strains. Excessive strains can lead to bone loss and implant failure according to Frost’s “Mechanostat” theory. To better understand the implant biomechanical environment, numerical simulation (FEA) is invaluable for correlating implant and bone parameters with strain fields in adjacent bone. The goal was to establish key relationships between short implant geometry, bone quality and quantity, and strain levels in the adjacent bone of patient-dependent elasticity to mitigate the risk of implant failure by avoiding pathological strains. Methods: Nine Bicon Integra-CP™ implants were chosen. Using CT scans, three-dimensional models of the posterior maxilla were created in Solidworks 2022 software to represent the most challenging scenario with minimal available bone, and the implant models were positioned in the jaw with the implant apex supported by the sinus cortical bone. Outer dimensions of the maxilla segment models were determined based on a prior convergence test. Implants and abutments were considered as a single unit made of titanium alloy. The bone segments simulated types III/IV bone by different cancellous bone elasticities and by variable cortical bone elasticity moduli selected based on an experimental data range. Both implants and bone were treated as linearly elastic and isotropic materials. Boundary conditions were restraining the disto-mesial and cranial surfaces of the bone segments. The bone–implant assemblies were subjected to oblique loads, and the bone’s first principal strain fields were analyzed. Maximum strain values were compared with the “minimum effective strain pathological” threshold of 3000 microstrain to assess the implant prognosis. Results: Physiological strains ranging from 490 to 3000 microstrain were observed in the crestal cortical bone, with no excessive strains detected at the implant neck area across different implant dimensions and cortical bone elasticity. In cancellous bone, maximum strains were observed at the first fin tip and were influenced by the implant diameter and length, as well as bone quality and cortical bone elasticity. In the spectrum of modeled bone elasticity and implant dimensions, increasing implant diameter from 4.5 to 6.0 mm resulted in a reduction in maximum strains by 34% to 52%, depending on bone type and cortical bone elasticity. Similarly, increasing implant length from 5.0 to 8.0 mm led to a reduction in maximum strains by 15% to 37%. Additionally, a two-fold reduction in cancellous bone elasticity modulus (type IV vs. III) corresponded to an increase in maximum strains by 16% to 59%. Also, maximum strains increased by 86% to 129% due to a decrease in patient-dependent cortical bone elasticity from the softest to the most rigid bone. Conclusions: The findings have practical implications for dental practitioners planning short finned implants in the posterior maxilla. In cases where the quality of cortical bone is uncertain and bone height is insufficient, wider 6.0 mm diameter implants should be preferred to mitigate the risk of pathological strains. Further investigations of cortical bone architecture and elasticity in the posterior maxilla are recommended to develop comprehensive clinical recommendations considering bone volume and quality limitations. Such research can potentially enable the placement of narrower implants in cases of insufficient bone. Full article
Show Figures

Figure 1

13 pages, 12717 KB  
Article
Workflow for Maxilla/Mandible Individual [Mai®] Implant by Integra Implants—How Individual Implants Are Manufactured
by Rafał Zieliński, Agata Kołkowska, Jerzy Sowiński, Bartłomiej Konieczny, Marcin Kozakiewicz and Wojciech Simka
Biomedicines 2024, 12(8), 1773; https://doi.org/10.3390/biomedicines12081773 - 6 Aug 2024
Cited by 4 | Viewed by 2162
Abstract
The newest technology allows the medical industry to manufacture innovative products such as milled titanium prosthodontic parts in an implant for a screw-retained suprastructure. In the literature, there are some articles on the clinical usage of subperiosteal implants, but none of these publications, [...] Read more.
The newest technology allows the medical industry to manufacture innovative products such as milled titanium prosthodontic parts in an implant for a screw-retained suprastructure. In the literature, there are some articles on the clinical usage of subperiosteal implants, but none of these publications, either in PubMed or Google Scholar, thoroughly describe the workflow for the design and manufacture of individual implants for maxillofacial surgery with milled threads for a screw-retained prosthodontic bridge. The aim of the article is to present a step-by-step method of producing personalized implants, from the first steps of production to the implantation of the final product. The article includes information on patient qualification for surgery, computational preparation and skull printing, planning of Mai Implants®, meshing, 3D printing and milling, cleaning, rinsing, anodizing, and laser marking, as well as the cleaning and sterilization process in a hospital or dental clinic. A detailed description of implant production allows for the analysis of each step and the development of technology. The production of implants is an expensive procedure, but considering all the advantages of the Mai Implants® treatment and the disadvantages of alternatives, the product is worth the price. Full article
(This article belongs to the Special Issue Advances in 3D Printing and Biomaterials in Tissue Engineering)
Show Figures

Figure 1

17 pages, 4395 KB  
Article
Finite Element Analysis and Fatigue Test of INTEGRA Dental Implant System
by Rafał Zieliński, Sebastian Lipa, Martyna Piechaczek, Jerzy Sowiński, Agata Kołkowska and Wojciech Simka
Materials 2024, 17(5), 1213; https://doi.org/10.3390/ma17051213 - 6 Mar 2024
Cited by 11 | Viewed by 4422
Abstract
The study involved numerical FEA (finite element analysis) of dental implants. Based on this, fatigue tests were conducted according to the PN-EN 14801 standard required for the certification of dental products. Thanks to the research methodology developed by the authors, it was possible [...] Read more.
The study involved numerical FEA (finite element analysis) of dental implants. Based on this, fatigue tests were conducted according to the PN-EN 14801 standard required for the certification of dental products. Thanks to the research methodology developed by the authors, it was possible to conduct a thorough analysis of the impact of external and internal factors such as material, geometry, loading, and assembly of the dental system on the achieved value of fatigue strength limit in the examined object. For this purpose, FEM studies were based on identifying potential sites of fatigue crack initiation in reference to the results of the test conducted on a real model. The actions described in the study helped in the final evaluation of the dental system design process named by the manufacturer as INTEGRA OPTIMA 3.35. The objective of the research was to identify potential sites for fatigue crack initiation in a selected dental system built on the INTEGRA OPTIMA 3.35 set. The material used in the research was titanium grade 4. A map of reduced von Mises stresses was used to search for potential fatigue crack areas. The research [loading] was conducted on two mutually perpendicular planes positioned in such a way that the edge intersecting the planes coincided with the axis of the system. The research indicated that the connecting screw showed the least sensitivity (stress change) to the change in the loading plane, while the value of preload has a significant impact on the achieved fatigue strength of the system. In contrast, the endosteal implant (root) and the prosthetic connector showed the greatest sensitivity to the change in the loading plane. The method of mounting [securing] the endosteal implant using a holder, despite meeting the standards, may contribute to generating excessive stress concentration in the threaded part. Observation of the prosthetic connector in the Optima 3.35 system, cyclically loaded with a force of F ≈ 300 N in the area of the upper hexagonal peg, revealed a fatigue fracture. The observed change in stress peak in the dental connector for two different force application surfaces shows that the positioning of the dental system (setting of the socket in relation to the force action plane) is significantly decisive in estimating the limited fatigue strength. Full article
(This article belongs to the Special Issue State-of-the-Art Biomaterials Science and Bioengineering in Poland)
Show Figures

Figure 1

33 pages, 8090 KB  
Article
Finite Element Analysis of Subperiosteal Implants in Edentulism—On the Basis of the MaI Implant® by Integra Implants®
by Rafal Zielinski, Jerzy Sowinski, Martyna Piechaczek, Jakub Okulski and Marcin Kozakiewicz
Materials 2023, 16(23), 7466; https://doi.org/10.3390/ma16237466 - 30 Nov 2023
Cited by 15 | Viewed by 3872
Abstract
The MaI Implants® method offers a modern treatment option for specific patients who lack sufficient bone for traditional screw-based implants. The aim of the article is to use Finite Element Analysis (FEA) to examine the behavior of a subperiosteal implant under actual [...] Read more.
The MaI Implants® method offers a modern treatment option for specific patients who lack sufficient bone for traditional screw-based implants. The aim of the article is to use Finite Element Analysis (FEA) to examine the behavior of a subperiosteal implant under actual conditions within the oral cavity and to assess the impact of various mechanical factors on the durability of the MaI Implants®. A strength analysis was conducted using Finite Element Analysis for two models. The first was a single subperiosteal implant, while the second was a model of an arch consisting of two single subperiosteal implants connected by a bar. Based on the obtained results, it can be observed that the increase in load from 100 N to 800 N leads to an increase in displacements throughout the implant. Changing the angle from 90 to 30 degrees resulted in a 576% increase in the average displacement value across all multi-units. Stresses in the multi-units range from 23.7 MPa to 268.5 MPa. The lack of proper stabilization of the implant has the greatest impact on the results of displacements. Such displacements are significant for the later positioning of the implant compared to the initial conditions. Full article
(This article belongs to the Section Manufacturing Processes and Systems)
Show Figures

Figure 1

10 pages, 1188 KB  
Article
Comparison of INTEGRA and the Manual Method to Determine the Axis for Intraocular Lens Implantation—A Case Series of 60 Eyes
by Marcin Jaworski, Dorota Wyględowska-Promieńska, Piotr Jaworski, Michał Kowalski, Krzysztof Jaskot and Robert Bieda
Healthcare 2022, 10(9), 1773; https://doi.org/10.3390/healthcare10091773 - 14 Sep 2022
Cited by 2 | Viewed by 2696
Abstract
(1) Background: To compare the results of a new intraoperative contactless device (INTEGRA Optomed, Poland) with the result of a manual method for determining the axis for toric intraocular lens implantation. (2) Material and Methods: This retrospective observational study included 60 eyes of [...] Read more.
(1) Background: To compare the results of a new intraoperative contactless device (INTEGRA Optomed, Poland) with the result of a manual method for determining the axis for toric intraocular lens implantation. (2) Material and Methods: This retrospective observational study included 60 eyes of 40 patients (17 men, 23 women) who had toric intraocular lenses implanted. A video recording of each surgery that used the INTEGRA system was made for the analysis. Two researchers then independently assessed the location of the implant axes determined with both digital and manual slit-lamp methods, and compared the results between methods. (3) Results: The implantation axes suggested through the manual and INTEGRA methods were similar. The median axis disparities were 0.0 degrees for both groups. The standard deviation was 0.63 and 0.75 for researcher 1 and 2, respectively. The dominant value was 0.0 in both groups. The INTEGRA axis designation was statistically significantly different from the manual method for researcher 1 (p < 0.05), but it was statistically insignificant for researcher 2 (p = 0.79). (4) Conclusions: The INTEGRA system is a digital ink-free device for image tracking scleral vessels. It was helpful for determining the implantation axis in a precise manner, and the measurements were comparable with those obtained through a manual technique. Full article
(This article belongs to the Topic Recent Trends in Image Processing and Pattern Recognition)
Show Figures

Figure 1

847 KB  
Article
Mini TightRope System for Hallux Abducto Valgus Deformity. A Discussion and Case Report
by Bryan Christopher West
J. Am. Podiatr. Med. Assoc. 2010, 100(4), 291-295; https://doi.org/10.7547/1000291 - 1 Jul 2010
Cited by 14 | Viewed by 105
Abstract
This case report reviews the presentation and treatment of a 68-year-old diabetic woman with severe hallux abducto valgus deformity and progressively worsening pain and joint stiffness. The patient had a history of two distinct episodes of postoperative deep venous thrombosis and was deemed [...] Read more.
This case report reviews the presentation and treatment of a 68-year-old diabetic woman with severe hallux abducto valgus deformity and progressively worsening pain and joint stiffness. The patient had a history of two distinct episodes of postoperative deep venous thrombosis and was deemed inappropriate for cast immobilization. The Arthrex Mini TightRope system was used in an attempt to reduce significantly increased intermetatarsal and hallux abductus angles, with the advantage of immediate postoperative weightbearing. An Integra K2 hemi-joint implant was also used to address the marked osteoarthritis at the first metatarsophalangeal joint. The potential role that this fixation technology may play in forefoot surgery is then discussed, along with its limitations and possible complications. Full article