Next Article in Journal
Two-Step Combined Ball Milling Strategy for FeCoCrNiCu High-Entropy Alloy Powders with Enhanced Compositional Homogeneity
Next Article in Special Issue
Cyclic Voltammetry-Assisted Electrodeposition of TiO2/PANI Thin Films on Boron-Doped Diamond and Fluorine-Doped Tin Oxide: Effect of Composition on Interfacial and Electrochemical Properties
Previous Article in Journal
First Principle Studies on the Reactivity and Stability of LiPF6 Surfaces in the Presence of Fluoride and Hydrogen Fluoride
Previous Article in Special Issue
Balancing Hydrophobicity and Water-Vapor Transmission in Sol–Silicate Coatings Modified with Colloidal SiO2 and Silane Additives
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Colorimetric Behaviour of Ceramic Zirconia Restorations Cemented on Darkened Substrates—In Vitro Study

1
Faculty of Dentistry, University of Porto, 4200-393 Porto, Portugal
2
Institute of Prosthodontics and Implant Dentistry, Faculty of Medicine, University of Coimbra, 3000-075 Coimbra, Portugal
3
Dentistry Department, Faculty of Medicine, University of Coimbra, 3000-075 Coimbra, Portugal
4
Centre for Innovation and Research in Oral Sciences (CIROS) and Institute of Prosthodontics and Implant Dentistry, Faculty of Medicine, University of Coimbra, 3000-075 Coimbra, Portugal
5
Centre for Mechanical Engineering, Materials and Processes (CEMMPRE) and Institute of Prosthodontics and Implant Dentistry, Faculty of Medicine, University of Coimbra, 3030-788 Coimbra, Portugal
*
Author to whom correspondence should be addressed.
Surfaces 2026, 9(1), 27; https://doi.org/10.3390/surfaces9010027
Submission received: 15 January 2026 / Revised: 7 March 2026 / Accepted: 10 March 2026 / Published: 12 March 2026

Abstract

The colour matching of ceramic restorations is sensitive to ceramic thickness, ceramic optical properties, the tooth region, the tooth/substrate basis colour, and the shade of the bonding agent. This in vitro study evaluates the influence of substrate darkening, resin cement shade and zirconia thickness on the final colour of monolithic Prettau®2 zirconia restorations. An in vitro factorial design was used combining four resin substrates simulating increasing darkening (ND6–ND9), three shades of dual-cure resin cement (universal, transparent, white opaque) and three zirconia thicknesses (0.5, 1.0, 1.5 mm) of Prettau®2 zirconia. Standardized photographs were taken under controlled conditions, and CIELAB coordinates (L*, a*, b*) were obtained in Adobe Photoshop. Colour differences relative to the Prettau®2 A1 shade tab were calculated as ΔL*, Δa*, Δb* and ΔE*. An additive linear model on ΔE* and a main-effect MANOVA on ΔL*, Δa* and Δb* were fitted to assess the impact of each factor. The mean ΔE* was 6.67 ± 2.66, and all but two specimens showed a clinically perceptible colour difference (ΔE* > 2.7) from the A1 shade tab. Substrate shade accounted for 38.4% of the explained variance in ΔE*, cement for 27.6% and zirconia thickness for 6.7%. MANOVA confirmed significant multivariate effects of substrate and cement, but not of zirconia thickness. Translucent monolithic zirconia showed limited ability to reproduce the A1 reference shade over darkened substrates. Substrate shade was the main determinant of colour mismatch, followed by resin cement, whereas zirconia thickness within 0.5–1.5 mm played a minor role. White opaque cement reduced ΔE* and brought the final shade closer to A1, but residual mismatches often remained clinically relevant. These findings highlight the need to control and, when possible, modify the underlying substrate and to select high-opacity cements when shade matching is critical.

1. Introduction

The colorimetric behaviour of a fixed ceramic restoration poses several challenges for dentists, especially when selecting the type of ceramic material to use and the characteristics of the bonding/adhesion agents in cases involving colour-altered (darkened) teeth [1]. In this scenario, the dentist faces the challenge of obtaining colorimetric properties similar to those of adjacent natural teeth, which is particularly significant when the prepared teeth are darkened, with varying intensity on a case-by-case basis [1,2].
Dental ceramics, recognized for their excellent colour stability, translucency, and ability to mimic tooth structure, stand out as restorative materials with colorimetric characteristics that resemble natural teeth [1,2,3]. This quest for faithful reproduction of colorimetric properties is essential to achieve optimal esthetic results and harmoniously integrate ceramic restorations with the natural esthetics of teeth [1].
Treatment success depends, among other factors, on the ability to achieve a perfect colour match between the restoration and the tooth. Complex variables are involved, including the colour of the tooth structure, the thickness of the ceramic, the colour and type of ceramic and resin cement, and the translucency of the restorative material resulting from the refracted and transmitted light [1,4]. Refraction and reflection occur infinitely on the surfaces of particles that are longer than the wavelength of light, resulting in light diffusion. The porosity of ceramic materials influences this phenomenon. The greater the difference in refractive index between the particle size and the ceramic matrix, the greater the refraction and reflection of light, which generally leads to an opaque effect in ceramic materials [5].
Highly translucent ceramic restorations allow light to pass through and scatter, especially at thinner thicknesses. Vitreous ceramic crowns have higher translucency than those with an alumina or zirconia base [4]. The influence of the dental substrate on the colour of restoration is evident, especially in translucent restorative materials, where the amount of light transmission through the ceramic plays a crucial role. Studies have shown that to mitigate the adjacent tooth’s darkened effect on the overall colour, vitreous ceramics should be at least 2.0 mm thick, which implies more extensive and less conservative preparations [6]. The underlying cement can, in turn, influence the visible reflected colour of ceramics such as feldspathic and lithium disilicate due to their translucency. Therefore, the colour matching of ceramic crowns is sensitive to the thickness of the ceramic, the tooth region, tooth/substrate basis colour and the shade of the bonding agent [7]. Mimicking different substrate colours is always a challenge in in vitro studies. In this regard, the use of prefabricated resins with different colours representing the natural and possible colours of the tooth substrates enhances the reliability and reproducibility of the protocols, as the colours are predefined in the material in a protocolized manner. Resin ND shades are an example of this material (IPS Natural Die Material, Ivoclar Vivadent, Schaan, Liechtenstein) and have been utilized in studies over time.
Notably, despite their excellent properties in biocompatibility, colour stability and mechanical strength, zirconia ceramics exhibit lower translucency than other ceramics [7]. Thus, the effect of cement on the colour of zirconia ceramics may differ depending on the level of translucency of the ceramics used [2,7,8,9]. This underscores the complexity and importance of meticulously considering these factors to obtain optimal esthetic and functional results in fixed ceramic restorations. In rehabilitation, colour communication between physicians and laboratory technicians is commonly performed visually and analogously, using pre-made or individualized colour scales to compare and convey the closest match to a natural tooth. However, this method is subjective, and its accuracy can be influenced by many factors, including the observer’s experience and training, the light source and tooth colour. In this matter, it is important to note that the teeth have unique colours and characteristics that combine colours and effects in different samples/references of the same scale (e.g., A3.5 body with B1 border and orange cervical region) [10,11]. Instrumental and digital methods have been developed and optimized to reliably enhance colour selection and communication. These methods are considered more accurate than the visual method alone. When possible, a combination of visual and instrumental methods is recommended. Among the instrumental methods used are colorimetric and spectrophotometric methods, applied and supported by digital readers, scanners, cross-polarization filters, digital cameras and smartphones. Choosing the most appropriate method depends on considerations such as reliability, accuracy, durability, cost, and the interpretability of clinicians and technicians in the laboratory [10,11,12]. This in vitro study focus on the following research question: what is the influence of ceramic thickness, cement characteristics, and substrate colour on the final colour perception of a ceramic restoration? The objective was to compare how different thicknesses of zirconia ceramics and cements with different colorimetric characteristics influence the final restoration colour on substrates with different levels of darkening. The null hypothesis is that there is no difference in colour perception, as measured by the L*, a*, b* system, between darkened substrates, ceramics and cement opacities.

2. Materials and Methods

2.1. Preparation of Ceramic Samples

Three specimens of Prettau® 2 Zirconia ceramics (Prettau® Zirconia, Zirkonzahn GmbH, Gais, Italy), LOT ZC3024D, were milled in the Zirkonzahn M2 Dual equipment (Zirkonzahn, Zirkonzahn GmbH, Gais, Italy), with dimensions 15 × 15 mm (length × width) and thicknesses of 0.5 mm, 1.0 mm and 1.5 mm. This zirconia ceramic is a high-translucency yttria-stabilized material (3Y-TZP), composed predominantly of ZrO2 stabilized with Y2O3 and small amounts of Al2O3, with trace levels of other oxides, and contains no polymeric phase.
One side of the specimens was glazed, and the other was sandblasted in the lab, mimicking the routine for restorations.

2.2. Preparation of Resin Samples

The simulation of the darkened substrates was made using a resin composite (IPS Natural Die Material; Ivoclar Vivadent AG, Schaan, Principality of Liechtenstein) of four different shades (ND6–ND9). The die subtrates are light-curing composite resins consisting of a polyester urethane dimethacrylate matrix, silicon dioxide filler, copolymers, initiators, stabilizers and pigments. The samples were prepared using a silicone mould with dimensions of 12 × 9 × 4 mm (length × width × thickness) to make the resin build up. For this, ND6-, ND7-, ND8- and ND9-coloured resin composites (IPS Natural Die Material, Ivoclar, Vivadent, Schaan, Liechtenstein) were applied with 1 mm increments spread into uniform layers, followed by 15 s polymerization (Bluephase® G2, Ivoclar Vivadent, Schaan, Liechtenstein) in SOFT START mode. For the last layer, the resins were covered with a 1 mm thickness glass slide so that the material was compressed under pressure to produce a smooth surface with reduced porosity. Final polymerization was promoted with the same light-curing unit set to the HIGH POWER mode for 40 s. The resin substrate samples were then polished using a resin composite finishing disc sequence (Sof-Lex™, 3M ESPE, Irvine, CA, USA) to ensure a smooth and polished surface. Figure 1 presents the visual aspect of the resin substrates after polishing.

2.3. Image Collection with the Resin Cement Shades

The zirconia samples were stabilized over the different colour substrates with three shades of dual cure resin cement (Bifix QM, VOCO GmbH, Cuxhaven, Germany) of transparent (T), white opaque (WO) and universal (U) shades. Bifix QM; VOCO is a dual-cure, resin-based adhesive cement containing a dimethacrylate resin matrix (e.g., Bis-GMA), benzoyl-peroxide/amine initiators and radiopaque barium–aluminum–borosilicate glass fillers. Thus, 4 study groups (respective to substrates), 3 groups (related to zirconia of different thickness) and 3 groups (related to cements of different opacities) were organized.
The simulated restorations were photographed using the different cements placed on each of the resin substrates. The cements were applied with the syringe provided by the manufacturer directly on the substrate, and then the zirconia ceramic was applied over the cement and digitally pressed, mimicking the pressure exerted on the clinical procedures to place an intraoral ceramic restoration. Photographs were taken and recorded for all substrate/ceramic/resin cements.
As the cement was not polymerized on each sample and to validate the colour change imposed by the polymerization, a sample of each cement was applied between two laminas of transparent glass and photographed before and after polymerization using the BluePhase G2 light-curing unit (Ivoclar Vivadent AG, Schaan, Principality of Liechtenstein) in the HIGH mode for 10 s for photopolymerization.

2.4. Photographic Protocol

In order to mimic as much as possible the intra-oral conditions, a head phantom was used for the colour-taking photographs, simulating the dark background of the oral cavity, as well as the existence of empty space between the sample/tooth and the oral tissues, which creates a particular optical effect on the teeth and, consequently, on the colour presented. A glass lamina was adapted to serve as support and a grey colour calibration card, Matisse® Photo Calibration Card (Labmatisse BV, Wijchen, The Netherlands), was also stabilized to standardize the tone of the photographs. The photographs were taken with a Tokina Macro 100 mm F2.8 D AT-X Pro objective lens (Tokina, Tokyo, Japan) mounted on a Nikon d750 camera (Nikon, Tokyo, Japan), and using a Nikon R1C1 flash (Nikon, Tokyo, Japan) with a polarizing filter (Polaris Filter) to reduce surface reflections. The set up was mounted on a tripod that ensured that the camera was kept at a constant distance from the objects, stable and without positional changes. The shots were taken using a remote control to avoid external interference with the camera or changes in positioning. Figure 2 presents the photographic set up.

2.5. Measurement of the Colorimetric Parameters

In 1973, Sproull defined the three-dimensional nature of colour, proposing the CIELab system that characterizes L* (luminosity), a* (red-green value) and b* (yellow-blue value), which was developed to produce a uniform colour space [13,14].
The colour measurements were performed in Adobe Photoshop, version 25.9.1. The images were transferred in JPEG format (Joint Photographic Experts Group) with no compression, and an area of 300 × 300 px was selected in the centre of the image. The colour values L*, a*, b* of the substrates, ceramics and cements were recorded, as well as the values of the ceramics applied with the cements over the substrates. The Commission Internationale de l’Eclairage (CIE) system allows the evaluation of the degree of perceptible colour change (ΔE*), based on the following three coordinates: L*, a* and b*. If ΔL* is positive, the sample is clearer than the reference; if it is negative, the sample is darker. Colour variations were determined of the target colour for the final restoration, that is the A1 Prettau® 2 ceramics (Zirkonzahn, Zirkonzahn GmbH, Gais, Italy) for which L*, a* and b* values were obtained from photographing shade tab under the same conditions [1].
Colour differences relative to the A1 Prettau® 2 zirconia shade tab were computed for each specimen as ΔL*, Δa*, Δb* and as the overall colour-difference metric ΔE*:
E *   =   L * 2 + ( a * ) 2 + ( b * ) 2
A ΔE* value greater than 1.2 was taken as indicating a clinically perceptible colour difference, whereas a ΔE* greater than 2.7 was taken as a non-acceptable colour difference, based on previously published thresholds for ceramic materials [15,16].

2.6. Statistical Analysis

All analyses were performed using R (RStudio 2025.09.1 + 401 “Cucumberleaf Sunflower” Release (20de356561bd58a6d88927cce948bd076d06e4ca, 23 September 2025) for windows). Colour measurements were expressed as CIELAB coordinates (L*, a*, and b*) and summarized as mean ± standard deviation (SD) and, when appropriate, 95% confidence intervals (95% CIs).
To obtain a single summary outcome reflecting global colour mismatch, an additive linear model was fitted with ΔE* as the dependent variable and substrate resin, cement and zirconia thickness as categorical predictors. Overall model significance was assessed with the F-test for the full model, and regression coefficients with 95% CI were estimated for each level of the three factors. The proportion of variance in ΔE* explained by each predictor (substrate resin, cement, and zirconia thickness) was quantified using the Lindeman–Merenda–Gold (LMG) relative importance metric, which decomposes the model R2 into non-negative contributions that sum to the total explained variance. To simultaneously evaluate the impact of substrate resin (ND6–ND9), cement (universal, transparent, and white opaque) and zirconia thickness (0.5, 1.0, and 1.5 mm) on the joint behaviour of the colour components, a main-effect multivariate analysis of variance (MANOVA) was fitted with ΔL*, Δa* and Δb* as dependent variables and the three experimental factors as fixed effects. Wilks’ Lambda was used as the multivariate test statistic, and, when significant, was followed by inspection of the corresponding univariate ANOVAs for each colour component. Interaction terms could not be estimated independently of the residual error and were therefore not included in the multivariate model. All statistical tests were two-sided, and a p-value < 0.05 was considered statistically significant.

3. Results

The descriptive statistics of the L*, a*, and b* values of each of the three factors are presented in Table 1, Table 2 and Table 3. As darkening of the substrate increases (from resin ND6 to ND9) there is a significant decrease in the lightness (L*) of the samples, as well as a change in the chromaticity (a* and b*). A significant difference in lightness is also noticed with the use of different cements (Table 2), with the lightest samples associated with the white opaque cement. However, this factor showed no impact on the chromaticity of the samples. When considering the different restoration thicknesses (Table 3), there are no significant differences in lightness and chromaticity of the samples, suggesting that this factor may play a least important role in the final colour of the restoration.
The mean ΔE* was 6.67 ± 2.66 and all samples except two presented a clinically perceptible and unacceptable colour variation (ΔE* > 2.7) from the reference scale (L*, a*, and b* values of the A1 Prettau® 2 zirconia clinical shade guide). The sample that combined the resin ND8, the white opaque cement and the 0.5 mm thickness zirconia presented the lowest colour variation, with ΔE* = 1.73. In more than 80% of the samples, the final colour was darker than the reference (negative variation in L*), whereas in only 11.1% of the samples the final colour was lighter than the reference and in the remaining cases no change was observed in lightness.
The additive linear model that was applied to the colour-difference ΔE* to examine the impact of the three main factors was adequate to describe the data and highly significant, F(7, 28) = 10.67, p < 0.001. Table 4 presents the coefficients obtained for the model. Relative to the reference substrate (resin ND6), all three tested substrates produced significantly lower ΔE*. Using the white opaque cement significantly decreased ΔE* relative to the reference (universal cement), whereas the transparent cement registered a colour variation similar to that of the universal cement (b = −0.16, p < 0.001). Compared to the reference thickness (1.5 mm), decreasing the zirconia to 1.0 mm yielded non-significant increase in ΔE* (b = 0.63, p = 0.328), while the 0.5 mm zirconia produced a larger increase (b = 1.65, p = 0.014), yet below the 2.7 acceptability threshold.
The full linear model accounted for 72.7% of the total response variance (total variance = 7.09, R2 = 0.6591). The Lindeman–Merenda–Gold metric (LMG) indicated that the proportions of explained variance attributable to each of the three predictors were 38.4%, 27.6% and 6.7% for resin, cement and zirconia thickness, respectively. Thus, the underlying substrate colour (resin) emerged as the most influential group of predictors in determining ΔE*, followed by the type of cement, whereas zirconia thickness had a comparatively minor effect.
A main-effect MANOVA with Wilks Lambda was also run to determine the impact of the three factors (resin substrate, cement and zirconia thickness) on the conjoint effect of L*, a* and b* change. The analysis revealed a significant multivariate effect of the resin substrate on the combined colour axis variables (Wilks’ Λ = 0.03, F(9, 63.4) = 22.21, p < 0.001), as well as a significant multivariate effect of the cement used (Wilks’ Λ = 0.28, F(6, 52) = 7.84, p < 0.001). On the contrary, the impact of zirconia thickness on the multivariate outcome on the combined effect of L*, a* and b* change was not significant (Wilks’ Λ = 0.72, F(6, 52) = 1.54, p = 0.19). Table 5 and Table 6 present the variation in the three colour components, L*, a* and b*, as well as the total colour variation, stratified by each of the significant factors in the multivariate analysis.
When referenced to the A1 Prettau shade tab, all resin substrates produced appreciable colour mismatches. ND6 generated the largest deviation, yielding restorations that were not statistically darker but markedly floated towards the red and yellow portions of the spectrum. ND7 and ND8 also shifted the colour away from the A2 shade tab, mainly through statistically significant darkening and increased yellowness, and virtually no shift in the red–green axis. ND9 led to a pronounced darkening combined with a subtle shift towards a greener hue.
Relative to the A1 Prettau reference tab, both the universal and transparent cements consistently produced significantly darker and warmer restorations, increasing yellowness. In contrast, the white opaque cement resulted in minimal non-significant darkening and a smaller, yet significant, yellow shift, keeping the final shade closer to the intended A1 shade tab.

4. Discussion

Colour can be described using the Munsell colour space, which considers hue, value, and chroma. In 1976, the Commission Internationale de l’Eclairage (CIE) defined the CIE Lab colour space. This space is based on the perception of colours in three segments: red, green, and blue. CIE Lab is widely recognized for being one of the most uniform colour spaces, where equal distances correspond to colour differences perceived as equal [15,17]. In the CIE Lab three-dimensional space, the axes are L*, a*, and b*. The L* value measures the luminosity of an object, with a value of zero representing a perfect black and 100 representing a perfect diffuse reflector. The value a* indicates the amount of red (positive) or green (negative), while the value b* indicates the amount of yellow (positive) or blue (negative). The a* and b* coordinates tend to approach zero for neutral colours (such as white and grey) and increase in magnitude for more saturated or intense colours [17]. The main advantage of the CIE Lab system is that colour differences can be expressed in units that are directly related to visual perception and clinical meaning. This facilitates communication and colour analysis in a variety of industrial and scientific applications [18]. The degree of colour perceptibility was estimated using the colour difference formula ΔE*, which provides a quantitative representation of the perceived colour difference between a pair of coloured samples under a given set of experimental conditions. The formula for calculating ΔE* is ΔE* = [(ΔL*)2 + (Δa*)2 + (Δb*)2]1/2, where the differences in luminosity and chromaticity coordinates (ΔL*, Δa*, and Δb*) are determined first (1,12). The ΔE* values represent the numerical distances between the L*, a*, and b* coordinates, and the magnitude of this value describes the clinically perceptible colour thresholds. A ΔE* value of 0 indicates a perfect colour match whereas values between 0.5 and 1.5 units are considered very good; between 1 and 2.7 are perceptible but acceptable; between 2.7 and 3.5 are clinically noticeable; and values higher than 3.5 are unacceptable [1,8,19].
This in vitro study evaluated how substrate shade (ND6–ND9), resin cement, and zirconia thickness influence the final colour of monolithic zirconia restorations referenced to the A1 Prettau® 2 shade tab. Overall, the restorative complex showed limited masking ability since the mean colour difference was ΔE* = 6.67 ± 2.66, and nearly all specimens exceeded the chosen threshold of ΔE* > 2.7 relative to the reference shade, indicating that most combinations were not only perceptible but also outside conventional acceptability ranges for a substantial proportion of clinicians and patients [15]. In addition, more than 80% of the specimens presented the final colour darker than A1 (negative ΔL*), confirming that darkening of the restorative complex is a frequent outcome when attempting to mask a darkened substrate. The null hypothesis of our study was rejected based on the results obtained. The increase in substrate darkening from ND6 to ND9 resulted in a progressive and significant reduction in lightness (L*) and changes in chromaticity (a* and b*). ND6 substrates yielded restorations that were only slightly darker than A1 but shifted clearly toward red and yellow, while ND7 and ND8 mainly produced darkening and increased yellowness with minimal change along the red–green axis. ND9 led to the greatest darkening, combined with a small shift towards a greener hue. Thus, the underlying resin shade did not merely scale brightness, but also altered hue and chroma in a substrate-dependent way.
Resin cement also emerged as a significant determinant of ΔE*, as previously recorded [20]. While the absolute L*, a*, and b* means suggested only a modest effect on chromaticity, the analysis of ΔL*, Δa*, and Δb* versus the A1 tab showed that universal and transparent cements consistently produced darker and warmer restorations, with a clear increase in yellowness. In contrast, the white opaque cement significantly reduced ΔE* relative to the universal cement and yielded only minimal, non-significant darkening and a smaller yellow shift. In practical terms, the white opaque cement kept the final shade closest to the desired A1 shade, although the average ΔE* still exceeded the usual acceptability thresholds for many observers. Recent in vitro work specifically investigating opaque cement shades over discoloured substrates confirms improved masking and reduced ΔE* compared with translucent cements, although complete masking is rarely achieved [5,20,21,22,23,24,25]. Our finding that the white opaque cement significantly lowered ΔE* and produced minimal darkening compared with universal/transparent cements is consistent with these observations and supports the clinical use of high-opacity cements when masking a discoloured abutment is a priority. At the same time, the residual ΔE* values indicate that cement alone cannot fully compensate for unfavourable substrate conditions.
Within the tested range (0.5, 1.0 and 1.5 mm), zirconia thickness had the least influence on the final colour. Neither L*, a*, b* nor ΔL*, Δa*, Δb* showed clinically meaningful differences across thicknesses, which was corroborated by the main-effect MANOVA that identified strong multivariate effects of resin and cement on the combined colour axes, whereas zirconia thickness did not contribute significantly to the multivariate outcome. Notwithstanding that, the linear model indicated that reducing zirconia thickness from 1.5 mm to 1.0 and 0.5 mm promoted an increase in ΔE* of 0.63 and 1.65 units, which was statistically significant for the 0.5 mm group. Despite being a variation below the adopted perceptibility threshold of 2.7 units, this variation reflects a trend for higher colour differences in lower zirconia thicknesses, emphasizing, as other authors also mention, the need for sufficient ceramic thickness for masking the darkened backgrounds, optimizing the colorimetric properties of the restoration and achieving the desired colour matches [7]. In fact, the relative importance analysis using the Lindeman–Merenda–Gold metric showed that substrate colour accounted for 38.4% of explained variance in ΔE*, followed by cement (27.6%) and zirconia thickness (6.7%), with the model explaining 65.9% of total variance, which reinforces the clinical message that, within the specific Prettau® 2 zirconia system tested, the underlying substrate and the choice of resin cement are the primary levers to optimize shade matching, while small changes in zirconia thickness play a comparatively minor role. Nonetheless, it is not possible to exclude a more important role of the restoration thickness in the masking ability [7,25,26,27] nor to exclude possible interactions between the three factors, as reported in the literature [22,28].
While these results generically align with the literature [29], they only align partially with those of a very similar study recently published by Xia et al. [28] that tested the impact of the substrate, cement, zirconia thickness and translucency on the colour variation from the target shade. The authors also used IPS Natural Die Refill resins to produce the substrate, two brands of zirconia to produce veneers with 0.5, 1.0 and 1.5 mm thickness and similar resin cements. All tested factors had a significant influence on ΔE* but, contrary to our study, zirconia thickness had a major role in the determination of colour variation and the luting cement had the least importance. However, the reported differences could be due to both the different background and colour measurement methods used in the two studies, as well as the zirconia itself.
The central role of the background substrate in determining the final shade of zirconia-based restorations has been thoroughly documented [22,28,30,31], and together with zirconia material and thickness, is one of the key determinants of the final colour in zirconia-based restorations. Translucent zirconia is often unable to fully mask dark or high-chroma substrates, with ΔE* values above acceptability thresholds even with samples presenting clinically relevant thickness. Our results are consistent with this evidence as none of the darker substrates yielded an acceptable match to the A1 reference. Interestingly, intermediate substrate shades (ND7 and ND8) reduced ΔE* compared to the lightest substrate (ND6), suggesting a non-linear relationship between substrate shade and colour mismatch that requires further exploration.
It is important to mention the limitations associated with the present findings. First, this was an in vitro study using resin discs to simulate darkened substrates and a standardized A1 Prettau® 2 shade tab as the reference. While this design allows strict control of variables, it does not fully reproduce the complexity of clinical situations, such as variations in tooth morphology, multilayered dentin–enamel structures, or soft-tissue influences. Consequently, the absolute ΔE* values should be interpreted with caution when extrapolating to natural teeth or implant abutments. Second, the experimental conditions were restricted to one zirconia system (Prettau® 2), one target shade (A1), and a limited set of substrate and cement shades from a single manufacturer. The relative contributions of substrate, cement and thickness may differ for other zirconia formulations (e.g., different yttria content, translucency levels or multilayered structures), other ceramic systems, or different resin cements. Similarly, due to the sample size per combination, only a linear additive model with main effects was considered; thus, potential interactions between substrate, cement and thickness were not explored and might be relevant, particularly in extreme combinations (very dark substrates with minimal thickness).
Notwithstanding these limitations, the present study reinforces the notion that effective masking of darkened substrates with translucent zirconia remains challenging. Clinically, careful control of the substrate shade and judicious use of high-opacity resin cements appear more impactful for shade matching than small adjustments in zirconia thickness within the usual restorative range.

5. Conclusions

Within the limitations of this in vitro study, translucent monolithic zirconia showed limited ability to reproduce the A1 reference shade over darkened substrates, with most combinations yielding ΔE* values above commonly accepted thresholds. Among the tested factors, substrate shade was the main determinant of colour mismatch, followed by resin cement, whereas zirconia thickness had only a minor influence within the 0.5–1.5 mm range. The white opaque cement consistently reduced ΔE* and kept the final shade closest to A1, although residual discrepancies remained clinically relevant. These findings highlight the need to control and, when possible, modify the underlying substrate and to select high-opacity cements when shade matching is critical.

Author Contributions

Conceptualization, R.D., F.G. and C.P.A.; methodology, R.Y. and C.P.A.; validation, A.M. and F.G.; formal analysis, A.M.; resources, R.D. and C.P.A.; data curation, R.Y.; writing—original draft preparation, A.M., R.D. and R.Y.; writing—review and editing, F.G.; supervision, A.M. and F.G.; funding acquisition, C.P.A. All authors have read and agreed to the published version of the manuscript.

Funding

This research is sponsored by national funds through FCT—Fundação para a Ciência e Tecnologia, under projects UID/00285/2025 and LA/P/0112/2020.

Data Availability Statement

The raw data supporting the conclusions of this article will be made available by the authors on request.

Acknowledgments

Special thanks to the Laboratory Technician, José Dinis, for providing the ceramic samples and VOCO company for supporting the resin cements.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Turgut, S.; Bagis, B.; Ayaz, E.A. Achieving the desired colour in discoloured teeth, using leucite-based CAD-CAM laminate systems. J. Dent. 2014, 42, 68–74. [Google Scholar] [CrossRef] [PubMed]
  2. Kumagai, N.; Hirayama, H.; Finkelman, M.D.; Ishikawa-Nagai, S. The effect of translucency of Y-TZP based all-ceramic crowns fabricated with difference substructure designs. J. Dent. 2013, 41, e87–e92. [Google Scholar] [CrossRef]
  3. Chang, J.; Da Silva, J.D.; Sakai, M.; Kristiansen, J.; Ishikawa-Nagai, S. The optical effect of composite luting cement on all ceramic crowns. J. Dent. 2009, 37, 937–943. [Google Scholar] [CrossRef] [PubMed]
  4. Mizrahi, B. The anterior all-ceramic crown: A rationale for the choice of ceramic and cement. Br. Dent. J. 2008, 205, 251–255. [Google Scholar] [CrossRef]
  5. Alqahtani, M.Q.; Aljurais, R.M.; Alshaafi, M.M. The effects of different shades of resin luting cement on the color of ceramic veneers. Dent. Mater. J. 2012, 31, 354–361. [Google Scholar] [CrossRef]
  6. Heffernan, M.J.; Aquilino, S.A.; Diaz-Arnold, A.M.; Haselton, D.R.; Stanford, C.M.; Vargas, M.A. Relative translucency of six all-ceramic systems. Part II: Core and veneer materials. J. Prosthet. Dent. 2002, 88, 10–15. [Google Scholar] [CrossRef]
  7. Tabatabaian, F.; Vora, S.; Mirabbasi, S. Effects of Ceramic Shade, Ceramic Thickness, and Surface Treatment on the Color Match of High-Translucency Monolithic Multilayer Zirconia Restorations. Int. J. Dent. 2025, 2025, 2004922. [Google Scholar] [CrossRef] [PubMed]
  8. Turgut, S.; Bagis, B.; Turkaslan, S.S.; Bagis, Y.H. Effect of ultraviolet aging on translucency of resin-cemented ceramic veneers: An in vitro study. J. Prosthodont. 2014, 23, 39–44. [Google Scholar] [CrossRef] [PubMed]
  9. Khosravani, S.R.; Kahnamoui, M.A.; Kimyai, S.; Navimipour, E.J.; Mahounak, F.S.; Azar, F.P. Final Colour of Ultratranslucent Multilayered Zirconia Veneers, Effect of Thickness, and Resin Cement Shade. Biomed Res. Int. 2022, 2022, 2555797. [Google Scholar] [CrossRef]
  10. Pecho, O.E.; Ghinea, R.; Perez, M.M.; Della Bona, A. Influence of Gender on Visual Shade Matching in Dentistry. J. Esthet. Restor. Dent. 2017, 29, E15–E23. [Google Scholar] [CrossRef]
  11. Mahn, E.; Tortora, S.C.; Olate, B.; Cacciuttolo, F.; Kernitsky, J.; Jorquera, G. Comparison of visual analog shade matching, a digital visual method with a cross-polarized light filter, and a spectrophotometer for dental color matching. J. Prosthet. Dent. 2021, 125, 511–516. [Google Scholar] [CrossRef] [PubMed]
  12. Jorquera, G.J.; Atria, P.J.; Galan, M.; Feureisen, J.; Imbarak, M.; Kernitsky, J.; Cacciuttolo, F.; Hirata, R.; Sampaio, C.S. A comparison of ceramic crown color difference between different shade selection methods: Visual, digital camera, and smartphone. J. Prosthet. Dent. 2022, 128, 784–792. [Google Scholar] [CrossRef]
  13. Sproull, R.C. Color matching in dentistry. II. Practical applications of the organization of color. J. Prosthet. Dent. 1973, 29, 556–566. [Google Scholar] [CrossRef] [PubMed]
  14. Sproull, R.C. Color matching in dentistry. I. The three-dimensional nature of color. J. Prosthet. Dent. 1973, 29, 416–424. [Google Scholar] [CrossRef] [PubMed]
  15. Paravina, R.D.; Perez, M.M.; Ghinea, R. Acceptability and perceptibility thresholds in dentistry: A comprehensive review of clinical and research applications. J. Esthet. Restor. Dent. 2019, 31, 103–112. [Google Scholar] [CrossRef]
  16. Paravina, R.D.; Ghinea, R.; Herrera, L.J.; Bona, A.D.; Igiel, C.; Linninger, M.; Sakai, M.; Takahashi, H.; Tashkandi, E.; Perez, M.d.M. Color difference thresholds in dentistry. J. Esthet. Restor. Dent. 2015, 27, S1–S9. [Google Scholar] [CrossRef]
  17. Joiner, A. Tooth colour: A review of the literature. J. Dent. 2004, 32, 3–12. [Google Scholar] [CrossRef]
  18. O’Brien, W.J.; Hemmendinger, H.; Boenke, K.M.; Linger, J.B.; Groh, C.L. Color distribution of three regions of extracted human teeth. Dent. Mater. 1997, 13, 179–185. [Google Scholar] [CrossRef]
  19. Tabatabaian, F. Color in Zirconia-Based Restorations and Related Factors: A Literature Review. J. Prosthodont. 2018, 27, 201–211. [Google Scholar] [CrossRef]
  20. Sakrana, A.A.; Laith, A.; Elsherbini, A.; Elerian, F.A.; Ozcan, M.; Al-Zordk, W. Influence of resin cement on color stability when luting lithium disilicate and zirconia restorations. A spectrophotometry study. Int. J. Esthet. Dent. 2023, 18, 114–126. [Google Scholar]
  21. Chen, S.; Jiang, L.; Chen, R. Masking Ability of the Combined Application of Opaque Resin Composite and High-Translucency Zirconia on Discolored Substrates. J. Esthet. Restor. Dent. 2025, 37, 2298–2306. [Google Scholar] [CrossRef] [PubMed]
  22. Comba, A.; Paolone, G.; Baldi, A.; Vichi, A.; Goracci, C.; Bertozzi, G.; Scotti, N. Effects of Substrate and Cement Shade on the Translucency and Color of CAD/CAM Lithium-Disilicate and Zirconia Ceramic Materials. Polymers 2022, 14, 1778. [Google Scholar] [CrossRef]
  23. Rajati Haghi, H.; Nejat, A.H.; Dashti, H.; Ghaemi, D.; Saeedi, F.; Yarmoradian, S. Effect of ceramic type, cement shade, and ceramic thickness on the optical properties of the definitive restoration and the ability to mask a metal substructure. J. Prosthet. Dent. 2025, 134, 760.e1–760.e7. [Google Scholar] [CrossRef] [PubMed]
  24. Soares, P.M.; Pereira, G.K.R.; Bacchi, A. Resin composite layering on discolored substrates ensures masking ability for monolithic ceramics. J. Esthet. Restor. Dent. 2023, 35, 860–868. [Google Scholar] [CrossRef]
  25. Tabatabaian, F.; Khaledi, Z.; Namdari, M. Effect of Ceramic Thickness and Cement Type on the Color Match of High-Translucency Monolithic Zirconia Restorations. Int. J. Prosthodont. 2021, 34, 334–340. [Google Scholar] [CrossRef]
  26. Soares, P.M.; Pilecco, R.O.; Bauken, G.; Pereira, G.K.R.; Bacchi, A. Masking Ability of Bleach-Shade Ceramics Applied Over Different Substrates: Influence of Opaque Stain Application and Ceramic Thickness. J. Esthet. Restor. Dent. 2025, 37, 2220–2229. [Google Scholar] [CrossRef]
  27. Tabatabaian, F.; Karimi, M.; Namdari, M. Color match of high translucency monolithic zirconia restorations with different thicknesses and backgrounds. J. Esthet. Restor. Dent. 2020, 32, 615–621. [Google Scholar] [CrossRef]
  28. Xia, Y.; Zhu, J.; Wang, W.; Liang, S.; Huang, C. Colour prediction for restoring discoloured teeth using zirconia veneers. J. Dent. 2025, 160, 105902. [Google Scholar] [CrossRef]
  29. Binici Aygun, E.; Kaynak Ozturk, E.; Tulu, A.B.; Turhan Bal, B.; Karakoca Nemli, S.; Bankoglu Gungor, M. Factors Affecting the Color Change of Monolithic Zirconia Ceramics: A Narrative Review. J. Funct. Biomater. 2025, 16, 58. [Google Scholar] [CrossRef]
  30. Hashem, D.; Al-Taee, L.A.; Mourad, S.I.; Elhelbawy, N.G.; Ahmed, K.E.; Mahmoud, S. Influence of zirconia thickness and background color on color matching accuracy of monolithic zirconia restorations. J. Dent. 2025, 160, 105922. [Google Scholar] [CrossRef] [PubMed]
  31. Hsu, W.C.; Peng, T.Y.; Kang, C.M.; Chao, F.Y.; Yu, J.H.; Chen, S.F. Evaluating the Effect of Different Polymer and Composite Abutments on the Color Accuracy of Multilayer Pre-Colored Zirconia Polycrystal Dental Prosthesis. Polymers 2022, 14, 2325. [Google Scholar] [CrossRef] [PubMed]
Figure 1. The darkened teeth mimicking resin substrates tested: (a) ND6 shade; (b) ND7 shade; (c) ND8 shade; (d) ND9 shade.
Figure 1. The darkened teeth mimicking resin substrates tested: (a) ND6 shade; (b) ND7 shade; (c) ND8 shade; (d) ND9 shade.
Surfaces 09 00027 g001
Figure 2. Photographic set up (a) showing the positioning of the samples in the head phantom with the corresponding calibration card and (b) showing camera positioning over the head phantom.
Figure 2. Photographic set up (a) showing the positioning of the samples in the head phantom with the corresponding calibration card and (b) showing camera positioning over the head phantom.
Surfaces 09 00027 g002
Table 1. Descriptive statistics of L*, a*, and b* values obtained stratified by the resin used to simulate the darkened substrate, regardless of the cement used and restoration thickness. Mean ± SD.
Table 1. Descriptive statistics of L*, a*, and b* values obtained stratified by the resin used to simulate the darkened substrate, regardless of the cement used and restoration thickness. Mean ± SD.
RESINL*a*b*
ND677.6 ± 1.35.1 ± 0.917.6 ± 2.3
ND776.2 ± 1.22.0 ± 0.513.8 ± 1.1
ND874.4 ± 2.22.1 ± 0.612.3 ± 1.7
ND971.7 ± 3.20.6 ± 0.58.2 ± 2.1
p-value<0.001<0.001<0.001
Table 2. Descriptive statistics of L*, a*, and b* values obtained stratified by cement, regardless of the substrate and restoration thickness. Mean ± SD.
Table 2. Descriptive statistics of L*, a*, and b* values obtained stratified by cement, regardless of the substrate and restoration thickness. Mean ± SD.
CEMENTL*a*b*
Transparent73.8 ± 2.92.7 ± 2.013.2 ± 4.2
Universal74.0 ± 3.32.8 ± 2.013.6 ± 4.0
White Opaque77.1 ± 1.71.9 ± 1.412.1 ± 3.3
p-value0.0090.4700.614
Table 3. Descriptive statistics of L*, a*, and b* values obtained stratified by zirconia thickness, regardless of the substrate and cement. Mean ± SD.
Table 3. Descriptive statistics of L*, a*, and b* values obtained stratified by zirconia thickness, regardless of the substrate and cement. Mean ± SD.
THICKNESSL*a*b*
0.5 mm74.1 ± 4.12.3 ± 2.112.2 ± 5.2
1.0 mm75.3 ± 2.82.4 ± 1.713.2 ± 3.4
1.5 mm75.5 ± 1.72.6 ± 1.613.5 ± 2.5
p-value0.4690.9450.674
Table 4. Coefficients obtained for the linear model on ΔE* for the different levels of the main factors.
Table 4. Coefficients obtained for the linear model on ΔE* for the different levels of the main factors.
EstimateStd ErrorTp-Value
Intercept9.520.7312.98<0.001
RESIN
ND6Ref
ND7−4.000.73−5.46<0.001
ND8−3.930.73−5.37<0.001
ND9−2.280.73−3.110.004
CEMENT
UniversalRef
Transparent−0.160.63−0.250.81
White opaque−3.000.63−4.73<0.001
THICKNESS
1.5 mmRef
1.0 mm0.630.630.990.328
0.5 mm1.650.632.600.014
Table 5. Descriptive statistics of the variation ΔL*, Δa*, Δb* and ΔE* obtained per resin used to simulate the darkened substrate, regardless of the cement used and restoration thickness. Mean [95% CI].
Table 5. Descriptive statistics of the variation ΔL*, Δa*, Δb* and ΔE* obtained per resin used to simulate the darkened substrate, regardless of the cement used and restoration thickness. Mean [95% CI].
RESINΔL*Δa*Δb*ΔE*
ND6−0.44 [−1.47, 0.58]3.11 [2.40, 3.82]8.56 [6.79, 10.30]9.22 [7.40, 11.1]
ND7−1.78 [−2.70, −0.85]0.00 [−0.38, 0.38]4.78 [3.94, 5.62]5.22 [4.31, 6.14]
ND8−3.56 [−5.28, −1.83]0.11 [−0.35, 0.57]3.33 [2.06, 4.61]5.29 [3.87, 6.71]
ND9−6.33 [−8.76, −3.90]−1.44 [−1.85, −1.04]−0.78 [−2.40, 0.84]6.94 [4.68, 9.20]
Table 6. Descriptive statistics of the variation ΔL*, Δa*, Δb* and ΔE* obtained per cement used to simulate the adhesion procedure, regardless of the darkened substrate below and restoration thickness. Mean [95% CI].
Table 6. Descriptive statistics of the variation ΔL*, Δa*, Δb* and ΔE* obtained per cement used to simulate the adhesion procedure, regardless of the darkened substrate below and restoration thickness. Mean [95% CI].
CEMENTΔL*Δa*Δb*ΔE*
Transparent−4.17 [−5.98, −2.35]0.67 [−0.59, 1.92]4.25 [1.55, 6.95]7.57 [5.92, 9.21]
Universal−4.00 [−6.08, −1.92]0.75 [−0.49, 2.00]4.58 [2.04, 7.13]7.72 [6.10, 9.35]
White Opaque−0.97 [−2.02, 0.18]−0.08 [−1.00, 0.83]3.08 [0.98, 5.19]4.72 [3.61, 5.83]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Dias, R.; Alves, C.P.; Yehudi, R.; Guerra, F.; Messias, A. Colorimetric Behaviour of Ceramic Zirconia Restorations Cemented on Darkened Substrates—In Vitro Study. Surfaces 2026, 9, 27. https://doi.org/10.3390/surfaces9010027

AMA Style

Dias R, Alves CP, Yehudi R, Guerra F, Messias A. Colorimetric Behaviour of Ceramic Zirconia Restorations Cemented on Darkened Substrates—In Vitro Study. Surfaces. 2026; 9(1):27. https://doi.org/10.3390/surfaces9010027

Chicago/Turabian Style

Dias, Ricardo, Cristiano Pereira Alves, Raul Yehudi, Fernando Guerra, and Ana Messias. 2026. "Colorimetric Behaviour of Ceramic Zirconia Restorations Cemented on Darkened Substrates—In Vitro Study" Surfaces 9, no. 1: 27. https://doi.org/10.3390/surfaces9010027

APA Style

Dias, R., Alves, C. P., Yehudi, R., Guerra, F., & Messias, A. (2026). Colorimetric Behaviour of Ceramic Zirconia Restorations Cemented on Darkened Substrates—In Vitro Study. Surfaces, 9(1), 27. https://doi.org/10.3390/surfaces9010027

Article Metrics

Back to TopTop